About this file
The file contains a Sources Sought Notice and Salient Characteristics List for the Department of the Air Force Air Combat Command, seeking market research for two complete disintegrator systems to be installed at Ellsworth AFB, South Dakota. The systems must meet specific technical requirements, including NSA/CSS listing, DIN Security Level 66399, compliance with classified and sensitive data destruction regulations, and ability to destroy paper, optical disks, and small e-media at a minimum of 900 lbs per hour. Key specifications include a 40 HP motor, 12" by 24" cutting chamber, solid steel rotor, integrated sound enclosure with up to 25 dBa noise reduction, and a five-year warranty.
Interested businesses are requested to submit company information by 12:00pm MDT on 28 April 2025, including contact details, CAGE Code, Unique Entity ID, GSA Contract Numbers, business size/socioeconomic status, capabilities statement, estimated lead time, and NAICS Code (339940). The systems must be delivered no later than September 1st, 2025, with the contractor responsible for procurement, shipping, and installation, including all electrical connections. The solicitation is for informational purposes only and does not constitute a commitment to procurement, with responses to be submitted electronically to A1C Vaishali Upadhyay and TSgt. Martelangelo M. Surop.
View the file
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment 1 – Salient Characteristics List Attachment 1 – Salient Characteristics List Salient Characteristics:
BACKGROUND: The MPF and LO Facilities require two complete disintegrator systems. The contractor will procure shipping to Ellsworth AFB. The contractor will also provide an installation team to install both complete systems.
OBJECTIVES: Attain two (2) complete disintegrator systems which include: one (1) Disintegrator, one (1) Filtration/collection system with bagged dust collection. Each system will also include a sound deadening encloser.
Installation: The MPF and LO facilities each require installation by the contractor. The contractor will make all electrical connections to the system.
Delivery: No later than September 1st 2025. The contractor will procure shipping of two (2) complete systems to Ellsworth AFB South Dakota.
Disintegrator Technical Specifications:
· Listed on NSA/CSS EPL for Paper Disintegrators, CDs, and Key Tape
· DIN Security Level: 66399 T-6, E-5, O-5, P-7
· Security Compliance: Classified, CUI/PII, NIST 800-88, DoD Emergency Destruction Guidelines, all commercial destruction regulations
· Media accepted: Paper, optical disks, small e-media
· NSA rated at a minimum 900 lbs. per hour
· Max partical size 3/32 inch
· Motor: 40 HP 460V/3-Phase/60Hz
· Soundproofed base and feed hopper
· 12” by 24” cutting chamber
· Solid steel (NO hollow spaces) rotor and seven blade cutting system
· Blades seated direct to rotor with minimum eight hold down bolts per blade
· Disintegrator integrated into complete system sound enclosure
· Included maintenance kit with spare set blades, tool kit, v-belts, waste collection bags Waste Collection and Dust Filtration System:
· Dual bag waste collection system with separate bottomless filter for bagged dust collection
· 1.5 HP 460V/3-Phase/60Hz
· 5” transition, collection hose, and hose cuffs
· Waste and dust collection system integrated into complete system sound enclosure Complete System Sound Enclosure:
· Sound Transmission Class (STC) – 37 rated
· Steel construction with minimum 2” fill 6 lb./cu/ft encapsulated mineral wool
· Gasket sealed doors
· Plexi view window for bag changes
· Fire retardant
· Up to 25 dBa noise reduction
· Integrated operator control center including one button start/stop, timed shutdown, key lock, and contains visual red light green light load metering system to prevent jamming
· Integrated junction box with electrical controls
Warranty:
· Five-year warranty on complete system Room Instalation Specifications:
· All components must pass through a 4 foot wide 7 foot tall door for installation
· Complete system with sound enclosure must fit in a 14 foot x 22 foot room image1.png