This document specifies the salient characteristics for a 20-foot Connex shipping container modification and delivery.
The container shall be a new, standard 1-trip shipping container painted in Tan RAL1015 exterior color, with delivery and unloading provided by the contractor. Access features include a 36-inch steel entry door with 80-inch height standard, located on the long front left side with Kwikset standard lockset and 2 keys, plus two 36-inch by 48-inch windows with vertical opening capability and screens. Interior construction requires 2LB spray foam insulation with 10.5 R-Value coverage on walls and ceiling with drywall, and 3/4-inch BC sanded plywood flooring that is covered and insulated.
The electrical package includes a 100-amp service panel located on the long back right side, serviced from the outside with commercial power connection capability and no generator inlet required. Interior lighting consists of four-foot LED fixtures with two fixtures containing two bulbs each, positioned in the ceiling center with 4000K color temperature providing 50-75 foot-candles at 30 inches from floor, controlled by dimmer switch located near the door entrance. Exterior LED floodlights with 4000K-5000K temperature are positioned above or near the entrance door. Four duplex receptacles (two on each long side wall, evenly spaced) provide 110-volt interior outlets only. Climate control is provided by an 18,500 BTU air conditioning unit with heat, frame, and weather cover.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| F3G3AA6103A0011 -Combo.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
20' Connex Salient Characteristics General Structure & Delivery
• 20' Standard 1-Trip Shipping Container-
• All items must be new
• Exterior Paint in New Container Tan RAL1015
• All items shall be delivered and unloaded by contractor
Doors & Windows
• 36" Steel Entry Door
• The height of the door standard is 80”
• The door should be located on long front left side of the container
• The 36” steel door entry require locks such as Kwikset, standard lockset with 2 keys
• Two 36” x 48” Windows
• The window needs to be 36”
• Windows should open vertically and window screens should be provided
• Vandal or tamper-resistant caging is not needed on the outside of the windows
Interior Finishes & Insulation
• Interior 2LB Spray Foam Insulation (10.5 R-Value)
• The walls and ceiling should be covered with drywall.
• The floor can be plywood, but ¾ BC sanded plywood is required.
• The floor needs to be covered and insulated along with the interior
Electrical, Lighting, & Comm
• Electric Package with 100 Amp Service Panel, Interior 4’ LED Lights, Exterior LED Floodlight, and Outlets
• Products shall allow container to commercial power. No generator inlet will be required.
• The service panel is serviced from the outside
• The service panel is located: The electrical and comm service panels should be located on the long back right side of the container.
• No exterior GFCI receptacles required-
• Four (4) duplex receptacles. Two (2) on each long side wall evenly spaced apart.
• Interior outlets only; Four (4) duplex, 110v outlets
• The switches for the LEDS are next to the door entrance
• The LED fixtures are controlled with a light switch dimmer
• The internal LEDS are in the center of the ceiling spaced evenly between the walls-
• The temperature of the internal LEDS must be 4000K
• The amount of internal LEDs are: Foot-candles should equal 50-75 at 30” from floor. Two (2) fixtures with two (2) bulbs each
• Floodlights shall be above or near entrance door
• Temperature floodlights shall be 4000K – 5000K
Climate Control (HVAC)
• 18,500 BTU A/C Unit with Heat + Frame and Weather Cover