About this file

This document is a detailed technical specification for an asphalt shingle roof replacement project for the Coleman State Park Warehouse located in Stewartstown, New Hampshire. The project involves a comprehensive roof replacement for a warehouse building, with specific installation requirements for asphalt shingles, including precise nailing patterns, cement application, and detailed placement instructions. The plans provide comprehensive roofing installation guidelines, including starter strip placement, drip edge installation, and specific techniques for different roof sections and weather conditions.

The technical drawings include multiple detailed views such as a warehouse roofing plan, roof sections, shingle installation details, and ridge vent installation specifications. The documentation emphasizes enhanced wind resistance techniques, such as using six nails per shingle, applying shingle tab adhesive, and using ice and watershield protective barriers. The plans also provide specific instructions for cold weather applications and maximum wind speed coverage, indicating a thorough approach to ensuring roof durability and performance under various environmental conditions. The project appears to be a state park infrastructure improvement initiative focused on maintaining and upgrading existing facilities.

View the file

Other files

File Type Posted
RFB DNCR CAP-2430.pdf PDF
rfb-dncr-cap-2430.pdf PDF
attachment-1-rfb-dncr-cap-2430.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FIRST COURSE

SECOND COURSE

17"

(432mm)

THIRD COURSE

6"

(152mm)11"

(279mm)

FOURTH COURSE

FIFTH COURSE

UNDERLAYMENT

FOURTH COURSE:

THIRD COURSE:

SECOND COURSE:

FIRST COURSE:

SHINGLE

INSTALLATION

REMAINING

COURSES:

NOTES:

ICE & WATERSHIELD

13-1/4" (368 - 445mm)

39-3/8" (1m)

ENHANCED NAILING PATTERN - six nails per shingle*

* required by some local codes and required for enhanced wind coverage on certain products.

See limited warranty for details.

5-3/4" - 6-1/4" (146mm - 159mm) from bottom of shingle

(13 - 64mm) 1/2" - 2-1/2"

(165 - 241mm) 6-1/2" - 9-1/2"

14-1/2" - 17-1/2"

(165 - 241mm) 6-1/2" - 9-1/2"

(368 - 445mm) 14-1/2" - 17-1/2"

Cement locations (4 quarter-sized dabs of cement on back of shingle)

CEMENT

HAND SEALING REQUIRED: TO HAND-SEAL SHINGLES AND TO ENSURE IMMEDIATE

SEALING, APPLY 4 QUARTER-SIZED DABS OF SHINGLE TAB ADHESIVE ON THE BACK OF

THE SHINGLE 1" (25 MM) AND 13" (330 MM) IN FROM EACH SIDE AND

1" (25 MM) UP FROM BOTTOM OF THE SHINGLE. PRESS SHINGLE FIRMLY INTO THE

ADHESIVE.

CAUTION: APPLY ONLY A THIN UNIFORM LAYER OF ASPHALT PLASTIC CEMENT LESS THAN

1/8" (3 MM) THICK. EXCESS AMOUNTS CAN CAUSE BLISTERING OF THE SHINGLES AND MAY

SOFTEN THE ASPHALT IN UNDERLAYMENTS AND LEAK BARRIERS, RESULTING IN THE

ASPHALT DRIPPING AND STAINING.

ASPHALT SHINGLE ROOF REPLACEMENT

COL27-WAREHOUSE

COLEMAN STATE PARK

ECKERD ALLEY WAY

STEWARTSTOWN, NH

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

PLUMBING VENT REPLACE ALUMINUM PIPE BOOT FLASHING

AutoCAD SHX Text

EXISTING CORRUGATED METAL ROOFING TO REMAIN

AutoCAD SHX Text

REMOVE ASPHALT SHINGLES INSTALL NEW ASPHALT SHINGLE ROOF

AutoCAD SHX Text

REMOVE ASPHALT SHINGLES INSTALL NEW ASPHALT SHINGLE ROOF

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

AutoCAD SHX Text

STATE OF NEW HAMPSHIRE

AutoCAD SHX Text

DEPARTMENT OF NATURAL AND CULTURAL RESOURCES

AutoCAD SHX Text

CAPITAL PROJECTS & MAINTENANCE

AutoCAD SHX Text

OF

AutoCAD SHX Text

AutoCAD SHX Text

STEWARTSTOWN, NEW HAMPSHIRE

AutoCAD SHX Text

COLEMAN STATE PARK

AutoCAD SHX Text

EDWARD MUSSEY

AutoCAD SHX Text

APPROVED BY:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text 1/4" = 1'-0"

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

JUN 10, 2025

AutoCAD SHX Text

PROJECT #

AutoCAD SHX Text

CAP-2430

AutoCAD SHX Text

TRIM 17" (432MM) OFF FIRST SHINGLE

AutoCAD SHX Text

TRIM 11" (279MM) OFF FIRST SHINGLE

AutoCAD SHX Text

TRIM 6" (152MM) OFF FIRST SHINGLE

AutoCAD SHX Text

START WITH FULL SHINGLE

AutoCAD SHX Text

START AT EITHER RAKE AND LAY IN EITHER DIRECTION

AutoCAD SHX Text PLACE FIRST COURSE OF SHINGLES 1/4" - 3/4" OVER EAVE AND RAKE EDGES, COVERING STARTER COURSE OVERHANG, TO PROVIDE DRIP EDGE.

AutoCAD SHX Text

1.CONTINUE EACH COURSE WITH WHOLE SHINGLES.

AutoCAD SHX Text REPEAT THE 1ST - 4TH COURSE INSTRUCTIONS ON THE REMAINING COURSES, STARTING THE FIFTH COURSE WITH A FULL SHINGLE.

AutoCAD SHX Text

2. STRIKE A CHALK LINE ABOUT EVERY 6 COURSES TO CHECK PARALLEL ALIGNMENT WITH EAVES.

AutoCAD SHX Text

DRIP EDGE HEM CORNERS

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SHINGLE INSTALLATION DETAILS

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

ALUMINUM DRIP EDGE APPLIED DIRECT TO THE ROOF DECK AT EAVES

AutoCAD SHX Text

ALUMINUM DRIP EDGE APPLIED OVER ICE AND WATERSHIELD AT RAKES

AutoCAD SHX Text Self seal adhesive on back

AutoCAD SHX Text Nail guide line

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

GAF ENHANCED NAILING PATTERN

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

GAF CEMENT LOCATIONS

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text 1"

AutoCAD SHX Text 3/8"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

ALUMINUM DRIP EDGE

AutoCAD SHX Text 3"=1'-0"

AutoCAD SHX Text

.032" ALUMINUM "MILL FINISH"

AutoCAD SHX Text

UNDERLAYMENT

AutoCAD SHX Text

EXISTING TRUSS

AutoCAD SHX Text

3' WIDE ICE & WATERSHIELD CENTERED AT CHANGE IN ROOF PITCH

AutoCAD SHX Text 20 OZ. ZINC COATED COPPER FLASHING 5" x 5"

AutoCAD SHX Text

UNDERLAYMENT

AutoCAD SHX Text

ICE & WATERSHIELD

AutoCAD SHX Text

GAF UHDZ ASPHALT SHINGLES

AutoCAD SHX Text REPLACE DETERIORATED PLYWOOD WITH 23"X32" RTD SHEATHING OR MATCH EXISTING PER SHEATHING REPLACEMENT ALLOWANCE

AutoCAD SHX Text

ASPHALT SHINGLES

AutoCAD SHX Text

3' WIDE COURSES OF ICE & WATERSHIELD CONTINUE TO RIDGE LINE

AutoCAD SHX Text

TRUSS

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

ROOF SECTION

AutoCAD SHX Text 1"=1'-0"

AutoCAD SHX Text

3' WIDE COURSE OF ICE & WATERSHIELD CENTERED ON CHANGE IN ROOF PITCH (TYPICAL)

AutoCAD SHX Text

ALUMINUM DRIP EDGE "MILL FINISH" AT EAVES AND RAKES (TYPICAL)

AutoCAD SHX Text

1ST COURSE OF 3' WIDE ICE & WATERSHIELD AT EAVES (TYPICAL)

AutoCAD SHX Text NOTES: 1. STRIP AND DISPOSE OF STRIP AND DISPOSE OF ALL ASPHALT SHINGLES AND UNDERLAYMENTS. 2.REPLACE DETERIORATED PLYWOOD SHEATHING. 3.INSTALL NEW DRIP EDGE, ICE & WATERSHIELD AND UNDERLAYMENT. 4.INSTALL ASPHALT SHINGLES. 5.INSTALL RIDGE CAP SHINGLES.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

3' WIDE COURSE OF ICE & WATERSHIELD AT RAKES (TYPICAL)

AutoCAD SHX Text

REMOVE ASPHALT SHINGLES INSTALL NEW ASPHALT SHINGLE ROOF

AutoCAD SHX Text REMOVE ASPHALT SHINGLES ICE & WATERSHIELD ENTIRE ROOF DECK AND INSTALL NEW ASPHALT SHINGLE ROOF

AutoCAD SHX Text

COL27 WAREHOUSE ROOF REPLACEMENT

AutoCAD SHX Text

COLEMAN STATE PARK

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

WAREHOUSE ROOFING PLAN

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text INSPECT THE EXISTING METAL ROOFING FOR MISSING OR BROKEN EXPOSED FASTENERS AND REPLACE AS NECESSARY.

AutoCAD SHX Text

3' WIDE COURSE OF ICE & WATERSHIELD CENTERED ON CHANGE IN ROOF PITCH (TYPICAL)

AutoCAD SHX Text

20 OZ. ZINC COATED COPPER CLEAT

AutoCAD SHX Text

2" X 10GA 6D RING SHANK COPPER NAIL 6" ON CENTER (TYP.)

AutoCAD SHX Text

CUPOLA

AutoCAD SHX Text

2ND COURSE OF 3' WIDE ICE & WATERSHIELD AT EAVES (TYPICAL)

AutoCAD SHX Text

ALUMINUM DRIP EDGE "MILL FINISH" AT EAVES AND RAKES. HEMMED CORNERS (TYPICAL)

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

HAND SEALING DETAIL

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

INSTALL RIDGE VENT

AutoCAD SHX Text

INSTALL RIDGE VENT

AutoCAD SHX Text

3' WIDE COURSE OF ICE & WATERSHIELD ABOVE CHANGE IN PITCH

AutoCAD SHX Text

3' WIDE COURSE OF ICE & WATERSHIELD ABOVE CHANGE IN PITCH

AutoCAD SHX Text

3' ICE & WATERSHIELD AROUND CUPOLA PENETRATION

AutoCAD SHX Text

REMOVE ASPHALT SHINGLES INSTALL NEW ASPHALT SHINGLE ROOF

AutoCAD SHX Text

3' WIDE COURSE OF ICE & WATERSHIELD CENTERED ON PLUMBING VENT

AutoCAD SHX Text INSPECT SIDEWALL FLASHING AT ROOF INTERFACE. REPLACE IF REQUIRED TO INSURE WATER TIGHT GUARNTEE.

8"

NAIL APPROXIMATELY 11

2"- 3"

(38 - 76MM) ABOVE THE BUTT

EDGE OF THE SHINGLE AND

APPROXIMATELY 1" - 2" (25 -

51MM) AND 10" - 12" (254 -

305MM) IN FROM OF EACH SIDE

OVERLAP EAVE EDGE STARTER

STRIP AT LEAST 3" (76MM)

FOR MAXIMUM WIND

RESISTANCE ALONG RAKES,

INSTALL GAF STARTER STRIP

SHINGLES AND CEMENT

SHINGLES TO UNDERLAYMENT

AND EACH OTHER IN A 4" (102

MM) WIDTH OF ASPHALT

PLASTIC CEMENT.

TM

TRIM 5" (127MM) FROM END OF FIRST

SHINGLE

START AT EITHER RAKE AND LAY IN EITHER DIRECTION

PLACE STARTER SHINGLE 14"

-3 4" (6 - 19MM) OVER EAVES

AND RAKE EDGES TO

PROVIDE DRIP EDGE.

5"

(127mm)

ALUMINUM DRIP EDGE "WHITE".

6" DECK FLANGE WITH 2"

FASCIA AND 34" DRIP.

ALONG

RAKE, PUT

NON-CORROSIVE

METAL DRIP

EDGE

ON TOP OF

SHINGLE-MATE

ROOF DECK

PROTECTION.

SHINGLE-MATE

ROOF DECK

PROTECTION

R

ALONG EAVES, PUT

SHINGLE-MATE ROOF DECK

PROTECTION ON TOP OF

NON-CORROSIVE METAL

DRIP EDGE.

6' min.

(1.83M)

4" END LAP

(102MM)

2" SIDE LAP

(52MM)

R

R

BETWEEN END

LAPS

*USE ICE & WATERSHIELD, WEATHER WATCH ,

STORMGUARD OR OTHER GAF LEAK BARRIER

ON ENTIRE ROOF DECK AS REQUIRED

R

R

12"

36" (914mm)

(305mm)

Perforations

9" (229mm)

12" (305mm)

Sealant

9" (229 mm)

12" (305 mm)

1" (25 mm)

1" (25 mm)

11.5" (292 mm)

Nail

FOR COLD WEATHER APPLICATION

· IN COLD WEATHER, WARM TIMBERTEX® RIDGE CAP SHINGLES

BEFORE BENDING.

· WHEN SELF-SEALING MAY BE DELAYED DUE TO COLD

WEATHER, APPLY QUARTER-SIZED DABS OF ASPHALT

PLASTIC CEMENT (MUST CONFORM TO ASTM D4586 TYPE I OR

TYPE II) BETWEEN RIDGE CAP PIECES AND PRESS FIRMLY TO

INSURE GOOD CONTACT BETWEEN PIECES.

FOR MAXIMUM WIND SPEED COVERAGE UNDER LTD. WARRANTY

· APPLY A 1/4” (6 MM) WIDE BEAD OF HENKEL PL® URETHANE

SEALANT OR SONNEBORN® NP-1™ URETHANE SEALANT TO

EACH RIDGE CAP SHINGLE 3/4”-1” (19MM - 25MM) FROM THE

SHINGLE EDGE, SET PARALLEL TO THE RIDGE (SEE FIGURE 3).

NOTE: EXCESSIVE APPLICATION OF TAB ADHESIVE CAN CAUSE

BLISTERING OF RIDGE CAP SHINGLE.

AutoCAD SHX Text (203mm)

AutoCAD SHX Text

EXPOSURE

AutoCAD SHX Text

NAIL 9" (229MM) FROM BOTTOM AND 1" (25MM) FROM EDGE

AutoCAD SHX Text

SELF-SEAL ADHESIVE ON BACK

AutoCAD SHX Text

BOTTOM BACKER

AutoCAD SHX Text

STARTER COURSE

AutoCAD SHX Text

TOP STRIP

AutoCAD SHX Text

GAF SHINGLE-MATE UNDERLAYMENT OVER ICE & WATERSHIELD ENTIRE ROOF DECK

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

AutoCAD SHX Text

STATE OF NEW HAMPSHIRE

AutoCAD SHX Text

DEPARTMENT OF NATURAL AND CULTURAL RESOURCES

AutoCAD SHX Text

OF

AutoCAD SHX Text

AutoCAD SHX Text

EDWARD MUSSEY

AutoCAD SHX Text

APPROVED BY:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text 1/4" = 1'-0"

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

JUN 10, 2025

AutoCAD SHX Text

PROJECT #

AutoCAD SHX Text

CAP-2430

AutoCAD SHX Text

ROOF REPLACEMENT

AutoCAD SHX Text NOTES: 1. STRIP AND DISPOSE STRIP AND DISPOSE ALL ASPHALT SHINGLE ROOFING AND DRIP EDGE. 2. INSTALL ICE & INSTALL ICE & WATERSHIELD ON ENTIRE ROOF DECK & ALONG EAVES, RAKES AND VALLEYS. 3. INSTALL DRIPEDGE. INSTALL DRIPEDGE. 4. INSTALL ASPHALT INSTALL ASPHALT SHINGLES. 5. PROVIDE INSTALLERS & PROVIDE INSTALLERS & SHINGLE MANUFACTURER WARRANTIES.

AutoCAD SHX Text NOTES: 1. LEAK BARRIER'S SHALL BE APPLIED IN FAIR LEAK BARRIER'S SHALL BE APPLIED IN FAIR WEATHER WHEN THE AIR, ROOF DECK, AND MEMBRANE ARE AT TEMPERATURES OF 40 F OR HIGHER. ROOF COVERING MATERIAL SHALL BE APPLIED AT TEMPERATURES OF 40 F OR HIGHER.

AutoCAD SHX Text

GAF TIMBERTEX RIDGE CAP 12" IN "PEWTER GRAY"

AutoCAD SHX Text

COBRA SNOW COUNTRY ADVANCED RIDGE VENT 11.5" (292 MM)

AutoCAD SHX Text

GAF UHDZ SHINGLES IN "PEWTER GRAY"

AutoCAD SHX Text

GAF SHINGLEMATE

AutoCAD SHX Text

ICE & WATERSHIELD ENTIRE ROOF DECK

AutoCAD SHX Text

EXISTING 5/8" PLYWOOD DECKING

AutoCAD SHX Text

EXISTING TRUSS

AutoCAD SHX Text NOTE: USE SUPPLIED 3" (76 MM) CORROSION RESISTANT RING SHANK NAILS INCLUDED WITH THE RIDGE VENT.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

COLEMAN STATE PARK

AutoCAD SHX Text

CAPITAL PROJECTS & MAINTENANCE

AutoCAD SHX Text

STEWARTSTOWN, NEW HAMPSHIRE

AutoCAD SHX Text

COLEMAN STATE PARK

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

TIMBERTEX INSTALLATION DETAIL

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

PROSTART INSTALLATION

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SHINGLE-MATE INSTALLATION DETAIL 4:12 OR MORE

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

RIDGE VENT DETAIL (TYPICAL)

AutoCAD SHX Text

NOT TO SCALE

Sheets and Views
COLEMAN WAREHOUSE ROOFING REPLACEMENT-SHEET 1 OF 2
COLEMAN WAREHOUSE ROOFING REPLACEMENT-SHEET 2 OF 2

File details come from the government source that posted it. Updated .