Attachment 1 - Replace Damaged Flooring - Drawings.pdf

PDF 8 MB Posted

Attached to
Z1DA--Replace Damaged Flooring 539-23-202
Solicitation number
36C25024B0019
Issued by

About this file

This solicitation is for a construction project to replace damaged flooring throughout a Department of Veterans Affairs hospital. The project scope includes removing all carpet left in the hospital as well as isolated toilets that may be the source of water damage. General construction, electrical, and technology work is required. The period of performance is 90 days from notice to proceed.

View the file

Other files

File Type Posted
36C25024B0019 0002.docx DOCX document
36C25024B0019 0001.docx DOCX document
36C25024B0019_1.docx DOCX document
Attachment 2 - Replace Damaged Flooring - Project Manual Specs.pdf PDF
36C25024B0019_1.pdf PDF
Attachment 7 - EMR.docx DOCX document
WD.txt TXT text file
Attachment 3 - VAAR 852.219-75 VA Notice of Limitations on Subcontracting (JAN 2023).pdf PDF
Attachment 4 - VHA_Directive_1192.pdf PDF
Attachment 5 - RFI Form-36C25023B0034.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

VA Project No.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

STAMP

CONSULTANTS:

321 4 5 6 7 8 9 10

5/8/2023 1:05:38 PM

REPLACE DAMAGED

FLOORING

05/11/2023

COVER SHEET

GI001

AHSS

539-23-202

CINCINNATI MEDICAL CENTER

VA Station No:

BID DOCUMENTS

CINCINNATI, OHIO

NORTH

PROJECT TEAM DRAWING SHEET INDEX

ENVIRONMENTAL ENGINEERING:

ARCHITECTURE:

OWNER: DESCRIPTIONSHEET ISSUE DATE

PHONE: 269.927.0144

SEVEN GENERATIONS AE

KALAMAZOO, MICHIGAN 49007

600 E. MICHIGAN AVE, SUITE B

ARC ENVIRONMENTAL

BALTIMORE, MARYLAND 21230

1311 HAUBERT ST.

VA CINCINNATI HEALTH CARE SYSTEM

CINCINNATI, OHIO 45220

3200 VINE STREET

REPLACE DAMAGED FLOORING

CINCINNATI, OHIO

DEPARTMENT OF VETERANS AFFAIRS

GI001 COVER SHEET 05/11/2023

GI002 GENERAL INFORMATION & SYMBOLS 05/11/2023

GC100 COMPOSITE AND PHASING PLAN - BASEMENT 05/11/2023

GC101 COMPOSITE AND PHASING PLAN - FIRST FLOOR 05/11/2023

GC102 COMPOSITE AND PHASING PLAN - SECOND FLOOR 05/11/2023

GC103 COMPOSITE AND PHASING PLAN - THIRD FLOOR 05/11/2023

GC104 COMPOSITE AND PHASING PLAN - FOURTH FLOOR 05/11/2023

GC107 COMPOSITE AND PHASING PLAN - SEVENTH FLOOR 05/11/2023

ID100 INTERIOR DEMOLITION PLANS 05/11/2023

IN100 FINISH KEY & DETAILS 05/11/2023

IN101 FINISH PLANS 05/11/2023

P001 PLUMBING GENERAL INFO & SYMBOL LEGEND, AND THIRD FLOOR DEMOLITION

PLAN

3/31/2023

E001 ELECTRICAL GENERAL INFO & SYMBOL LEGEND, AND THIRD FLOOR DEMOLITION

PLAN

3/31/2023

PROJECT LOCATION

PROJECT LOCATION

SCOPE PRIORITY ROOM SCHEDULE

ROOM

NUMBER ROOM NAME Area

ICRA

CLASS

PRIORITY 1

A251 STUDENT OFF. 70 SF CLASS II

A256 VIEWING 114 SF CLASS II

A257 READING ROOM 177 SF CLASS II

A258 READING ROOM 135 SF CLASS II

A259 ADM. 130 SF CLASS II

A260 CHIEF RADIOLOGY 188 SF CLASS II

A261 ADM. ASST. 199 SF CLASS II

A262 OFF. 141 SF CLASS II

A262A READING ROOM 105 SF CLASS II

A263 RESIDENT READING

ROOM

116 SF CLASS II

A264 READING ROOM 117 SF CLASS II

A300 VASC. LAB 148 SF CLASS II

A347 VASC. LAB 138 SF CLASS III

A347A TLT. 18 SF CLASS III

A379 VASC. LAB 277 SF CLASS II

B135 OFF. 116 SF CLASS II

C002 MEDICAL RECORDS

STORAGE

1,020 SF CLASS II

PRIORITY 1: 17 3,209 SF

PRIORITY 2

A144 DECEDENT AFFAIRS 186 SF CLASS II

A144A CONF. ROOM 198 SF CLASS II

A301 OFFICE 256 SF CLASS II

A302 CHIEF DIET. 145 SF CLASS II

A303 DIET SEC. 146 SF CLASS II

A321 CHIEF OFF. 149 SF CLASS II

A353 OFF. 162 SF CLASS II

A422A SOCIAL WORKER 130 SF CLASS II

A755 OFFICE #8 157 SF CLASS II

A770 TESTING 76 SF CLASS II

A775 OFFICE #18 146 SF CLASS II

B326 FAMILY WAITING 607 SF CLASS III

B327 RECEPTION 151 SF CLASS II

B711 OFF. 114 SF CLASS II

C037 AUD. BOOTH 102 SF CLASS II

C037A AUD. BOOTH 105 SF CLASS II

C314 ICU DIR. OFF. 151 SF CLASS II

C360 EMS 77 SF CLASS II

C3002 WAITING 427 SF CLASS III

C3005 CONSULT. 124 SF CLASS III

PRIORITY 2: 20 3,609 SF

Grand total: 37 6,818 SF

ENGINEERING:

PHONE: 269.585.2255

ALLIANCE | STEELHEAD JV

KALAMAZOO, MICHIGAN 49007

259 E. MICHIGAN AVE, SUITE 407

Revisions Date

Stephanie Sokolowski Snapshot

A300

A320

ARCHITECTURAL SYMBOLS & PLAN INDICATORS

ABBREVIATIONSBARRIER-FREE DESIGN INFORMATION

ROOMNAME

XXX

A

A

A

A

8'-0"

TOP OF STEEL

ELEV. 10'-0"

A200

TITLE

SCALE X" = 1'-0"

TYP. BARRIER FREE TOILET ROOM FIXTURES

SCALE: NONE

TYP. BARRIER FREE TOILET ROOM FIXTURES

SCALE: NONE

OBSTRUCTED APPROACH UNOBSTRUCTED APPROACH

TYP. CODE REGULATED MOUNTING HEIGHTS

SCALE: NONE

TYP. EQUIPMENT MOUNTING HEIGHTS

SCALE: NONE

ELEVATION INDICATION

SHEET NO.

ELEVATION NUMBER

SECTION INDICATOR

ENLARGED PLAN OR

ELEVATION

PROPOSED SPOT

EXISTING SPOT

ELEVATION

100.57'

100.57'

STRUCTURAL SPAN

ROOF TRUSSES

FLOOR JOIST OR

RAMP

@ 16" O.C.

2 x 12

1" per 12"

SLOPE UP

REVISION TAG W/

REVISION NUMBER

KEYNOTE TAG

WINDOW TAG W/

WINDOW TYPE

INDICATOR

WALL SECTION CUT

COLUMN LINE

WALL TYPES

ELEVATION

BUILDING SECTION CUT

SHEET LOCATION

DETAIL NUMBER

TYPICAL

DIMENSIONING

SET-BACK LINE

PROPERTY LINE

EXISTING

CONTOUR

TOPOGRAPHY

CONTOUR

100'

100'

TOPOGRAPHY

PROPOSED

SECTIONS & DETAILS

TYPICAL TITLE FOR

DOOR NUMBER

DOOR TAG W/

ROOM NUMBER

ROOM NAME/

NORTH ARROW

60" DIAMETER CLEAR

WHEELCHAIR TURNING

SPACE - REFER TO PLAN

- REFER TO PLAN

AND GROUND SPACE

30" x 48" CLEAR FLOOR

CEILING HEIGHT TAG

MIRRORGRAB

BARS

TOILET PAPER

GRAB BARS

5'-0" DIA.

CLEAR FLOOR

SPACE

60" WIDE BY 59" DEEP

CLEAR FLOOR AREA AT

WATER CLOSET

2'-6" x 4'-0"

CLEAR FLOOR

AREA AT SINK

* DIMENSION IS TO BOTTOM

OF REFLECTIVE SURFACE

RECEPTACLE

LIGHT

SWITCH

HVAC

CONTROLS

FIRE

ALARM

FEC

LESS THAN 40#

FEC

GREATER THAN 40#

TEL

PUSH PAD

RH/CH

GBX

SH1

CL

OT

SPH

CRK SND

PT

SD

HS

XR COM4 MR

CRBG

WP

TP SNR

4'-4"

TV

MOUNTING HEIGHT GENERAL NOTES:

1. ITEMS ON THIS SHEET ARE NOT NECESSARILY

INCLUDED IN THIS PROJECT.

2. CONTRACTOR TO VERIFY ALL EQUIPMENT

MOUNTING HEIGHTS WITH OWNER/AE

PRIOR TO INSTALLATION.

3. REFER TO MECHANICAL/ELECTRICAL

DRAWINGS FOR DEVICE MOUNTING

HEIGHTS.

XXXNORTH

M A

X

M

IN

/1

" 4

" 5

M A

X

6" 3' - 0"

1' - 6" 3' - 6"

MIN

1' - 3"

5' - 0"

M

IN

6" 3' - 0"

M A

X

3' - 6" 1' - 0"

M

IN

M

A X

M

IN

M

IN

M A

X

SIDE FRONT

M

A X

M

A X

20" - 25"

M

A X

FRONT

M

A X

20" MAX

SIDE

SIDE FRONT

M

IN

M

A X

M

IN

M

A X

@ AT

A/C AIR CONDITIONING/AIR CONDITIONER

ACOUS ACOUSTICAL

AD AREA DRAIN, AUTOMATIC DAMPER

ADJ ADJUST, ADJUSTABLE

ALUM ALUMINUM

AP ACCESS PANEL

ACT ACOUSTICAL CEILING

B BASE

BAR BARRIER

BD BOARD

BF BARRIER FREE

BKT BRACKET

BLDG BUILDING

BLKG BLOCKING

BOTT BOTTOM

C TO C CENTER TO CENTER

CAB CABINET

CE COLUMN ENCLOSURE

CIR CIRCLE

CIR CIRCUIT

CL CENTER LINE, CLEARANCES

CLG CEILING

CJ CONTROL JOINT

CLKG CAULKING

CLO CLOSET

CMT CERAMIC MOSAIC TILE

CMU CONCRETE MASONRY UNIT

CO CLEANOUT

COL COLUMN

CONC CONCRETE

CONT CONTINUOUS

CORR CORRIDOR

CPT CARPET

CSS CLINICAL SERVICE SINK

CT CERAMIC TILE

CTR CENTER

CUH CABINET UNIT HEATER

DEMO DEMOLITION, DEMOLISH

DEPT DEPARTMENT

DF DRINKING FOUNTAIN

DIA, D DIAMETER

DIM DIMENSION

DN DOWN

DR DRAIN

DS DOWNSPOUT

ELECT ELECTRICAL

ELEV ELEVATION

ENTR ENTRANCE

EQ EQUAL

EP ELECTRICAL PANEL

EXH EXHAUST

EXP EXPOSED

EXIST EXISTING, EXSIST'G

EXT EXTERIOR

EW EACH WAY

FA FIRE ALARM

FD FIRE DAMPER OR FLOOR DRAIN

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

FIN FINISH

FL, FLR FLOOR FINISH

FLG, FLRG FLOORING, FLOOR'G

FURN FURNITURE, FURNACE

FWC FABRIC WALL COVERING

FT FEET, FOOT

GALV GALVANIZE(D)

GL GLASS

GSB GYPSUM SHEATHING BOARD

GWB GYPSUM WALLBOARD

GYP. BD GYPSUM BOARD

ID INSIDE DIAMETER

INSUL INSULATION

IN INCH(ES)

JAN JANITOR'S CLOSET

HM HOLLOW METAL

HORIZ HORIZONTAL

HR HANDRAIL

HT HEIGHT

HW HEADWALL

LAM LAMINATED

LF LINEAL FEET

MAS MASONRY

MAT'L MATERIAL

MAX MAXIMUM

MECH MECHANICAL

MANUF MANUFACTURED, MANUFACTURER

MIN MINIMUM

MLD'G MOLDING

MTL METAL

N NORTH

NAT NATURAL

NIC NOT IN CONTRACT

NORM NORMAL

NTS NOT TO SCALE

O.C. ON CENTER

OPN'G OPENING

O, O2 OXYGEN

PLAST PLASTIC

PNT PAINT

PREFAB PREFABRICATED

PLYWD PLYWOOD, PLYW'D

R RADIUS

RA RETURN AIR

REQ'D REQUIRED

RM ROOM

S SINK, SOUTH, SHINGLE

SA SUPPLY AIR

SAN SANITARY

SMKD SMOKE DAMPER

SECT SECTION

SHWR SHOWER

SIM SIMILAR

SPEC SPECIFICATION

SQ SQUARE

SS SERVICE SINK, STAINLESS STEEL

STD STANDARD

STOR STORAGE

SUSP SUSPEND(ED)

SYM SYMBOL, SYMMETRICAL

TOIL TOILET

TYP TYPICAL

UNFIN UNFINISHED

UTIL UTILITY

VAC VACUUM

VAV VARIABLE AIR VOLUME

VCT VINYL COMPOSITION TILE

VD VOLUME DAMPER

VERT VERTICAL

V.I.F. VERIFY IN FIELD

VT VINYL TILE

VWC VINYL WALL COVERING

W/ WITH

WC WATER CLOSET

WD WOOD

WNDW WINDOW

W. HTR WATER HEATER

W/O WITHOUT

WP WALL PROTECTION

A420

A320

M

A X

M

IN

18" MAX.

16" MIN.

IF

B A

R R

IE

R

F R

E E

M

A X

M

IN

M

IN

VA Project No.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

STAMP

CONSULTANTS:

321 4 5 6 7 8 9 10

5/8/2023 1:05:38 PM

REPLACE DAMAGED

FLOORING

05/11/2023

GENERAL INFORMATION &

SYMBOLS

GI002

AHSS

539-23-202

CINCINNATI MEDICAL CENTER

VA Station No:

BID DOCUMENTS

Revisions Date

5/8/2023 1:05:38 PM

DN

1020 SF

C002

MEDICAL RECORDS

STORAGE

102 SF

C037

AUD. BOOTH

105 SF

C037A

AUD. BOOTH

ID100

IN101

IN101

ID100

PHASING LEGEND

AREAS INCLUDED IN CONTRACT SCOPE OF WORK

INDICATES AREA REQUIRING AFTER-HOURS LABOR.

AREA SHALL REMAIN OPEN TO REGULAR

OPERATIONS DURING NORMAL BUSINESS HOURS.

ALL DEMO & NEW WORK SHALL TAKE PLACE

DURING THE WINDOW OF 6:00 PM - 5:00 AM

MONDAY THROUGH FRIDAY AND ALL DAY

SATURDAYS & SUNDAYS.

VA Project No.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

STAMP

CONSULTANTS:

321 4 5 6 7 8 9 10

5/8/2023 1:05:42 PM

REPLACE DAMAGED

FLOORING

05/11/2023

COMPOSITE AND PHASING PLAN -

BASEMENT

GC100

AHSS

539-23-202

CINCINNATI MEDICAL CENTER

VA Station No:

BID DOCUMENTS

N Scale: 1/16" = 1'-0"

BASEMENT PLAN

198 SF

A144A

CONF. ROOM

116 SF

B135

OFF.

ID100

IN101

ID100

IN101

186 SF

A144

DECEDENT AFFAIRS

PHASING LEGEND

AREAS INCLUDED IN CONTRACT SCOPE OF WORK

INDICATES AREA REQUIRING AFTER-HOURS LABOR.

AREA SHALL REMAIN OPEN TO REGULAR

OPERATIONS DURING NORMAL BUSINESS HOURS.

ALL DEMO & NEW WORK SHALL TAKE PLACE

DURING THE WINDOW OF 6:00 PM - 5:00 AM

MONDAY THROUGH FRIDAY AND ALL DAY

SATURDAYS & SUNDAYS.

VA Project No.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

STAMP

CONSULTANTS:

321 4 5 6 7 8 9 10

5/8/2023 1:05:49 PM

REPLACE DAMAGED

FLOORING

05/11/2023

COMPOSITE AND PHASING PLAN -

FIRST FLOOR

GC101

AHSS

539-23-202

CINCINNATI MEDICAL CENTER

VA Station No:

BID DOCUMENTS

N Scale: 1/16" = 1'-0"

FIRST FLOOR PLAN

IN101

IN101

177 SF

A257

READING ROOM

135 SF

A258

READING ROOM

130 SF

A259

ADM.

188 SF

A260

CHIEF RADIOLOGY

199 SF

A261

ADM. ASST.

141 SF

A262

OFF.

117 SF

A264

READING ROOM

105 SF

A262A

READING ROOM

70 SF

A251

STUDENT OFF.

ID100

ID100

116 SF

A263

RESIDENT READING

ROOM

114 SF

A256

VIEWING

PHASING LEGEND

AREAS INCLUDED IN CONTRACT SCOPE OF WORK

INDICATES AREA REQUIRING AFTER-HOURS LABOR.

AREA SHALL REMAIN OPEN TO REGULAR

OPERATIONS DURING NORMAL BUSINESS HOURS.

ALL DEMO & NEW WORK SHALL TAKE PLACE

DURING THE WINDOW OF 6:00 PM - 5:00 AM

MONDAY THROUGH FRIDAY AND ALL DAY

SATURDAYS & SUNDAYS.

VA Project No.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

STAMP

CONSULTANTS:

321 4 5 6 7 8 9 10

5/8/2023 1:05:57 PM

REPLACE DAMAGED

FLOORING

05/11/2023

COMPOSITE AND PHASING PLAN -

SECOND FLOOR

GC102

VGSS

539-23-202

CINCINNATI MEDICAL CENTER

VA Station No:

BID DOCUMENTS

N Scale: 1/16" = 1'-0"

SECOND FLOOR PLAN

UP

UP

UP

UP

IN101

IN101

IN101

IN101

IN101

IN101

IN101

IN101

IN101

124 SF

C3005

CONSULT.

427 SF

C3002

WAITING

148 SF

A300

VASC. LAB

256 SF

A301

OFFICE

145 SF

A302

CHIEF DIET.

146 SF

A303

DIET SEC.

162 SF

A353

OFF.

277 SF

A379

VASC. LAB

607 SF

B326

FAMILY WAITING

151 SF

B327

RECEPTION

77 SF

C360

EMS

151 SF

C314

ICU DIR. OFF.

149 SF

A321

CHIEF OFF.

ID100

ID100

ID100

ID100

ID100

ID100

ID100

ID100

ID100

19 SF

C3005A

138 SF

A347

VASC. LAB

PHASING LEGEND

AREAS INCLUDED IN CONTRACT SCOPE OF WORK

INDICATES AREA REQUIRING AFTER-HOURS LABOR.

AREA SHALL REMAIN OPEN TO REGULAR

OPERATIONS DURING NORMAL BUSINESS HOURS.

ALL DEMO & NEW WORK SHALL TAKE PLACE

DURING THE WINDOW OF 6:00 PM - 5:00 AM

MONDAY THROUGH FRIDAY AND ALL DAY

SATURDAYS & SUNDAYS.

VA Project No.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

STAMP

CONSULTANTS:

321 4 5 6 7 8 9 10

5/8/2023 1:06:10 PM

REPLACE DAMAGED

FLOORING

05/11/2023

COMPOSITE AND PHASING PLAN -

THIRD FLOOR

GC103

AHSS

539-23-202

CINCINNATI MEDICAL CENTER

VA Station No:

BID DOCUMENTS

N Scale: 1/16" = 1'-0"

THIRD FLOOR PLAN

IN101

130 SF

A422A

SOCIAL WORKER

ID100

PHASING LEGEND

AREAS INCLUDED IN CONTRACT SCOPE OF WORK

INDICATES AREA REQUIRING AFTER-HOURS LABOR.

AREA SHALL REMAIN OPEN TO REGULAR

OPERATIONS DURING NORMAL BUSINESS HOURS.

ALL DEMO & NEW WORK SHALL TAKE PLACE

DURING THE WINDOW OF 6:00 PM - 5:00 AM

MONDAY THROUGH FRIDAY AND ALL DAY

SATURDAYS & SUNDAYS.

VA Project No.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

STAMP

CONSULTANTS:

321 4 5 6 7 8 9 10

5/8/2023 1:06:18 PM

REPLACE DAMAGED

FLOORING

05/11/2023

COMPOSITE AND PHASING PLAN -

FOURTH FLOOR

GC104

AHSS

539-23-202

CINCINNATI MEDICAL CENTER

VA Station No:

BID DOCUMENTS

N Scale: 1/16" = 1'-0"

FOURTH FLOOR PLAN

IN101

IN101

IN101

IN101

146 SF

A775

OFFICE #18

157 SF

A755

OFFICE #8

76 SF

A770

TESTING

114 SF

B711

OFF.

ID100

ID100

ID100

ID100

PHASING LEGEND

AREAS INCLUDED IN CONTRACT SCOPE OF WORK

INDICATES AREA REQUIRING AFTER-HOURS LABOR.

AREA SHALL REMAIN OPEN TO REGULAR

OPERATIONS DURING NORMAL BUSINESS HOURS.

ALL DEMO & NEW WORK SHALL TAKE PLACE

DURING THE WINDOW OF 6:00 PM - 5:00 AM

MONDAY THROUGH FRIDAY AND ALL DAY

SATURDAYS & SUNDAYS.

VA Project No.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

STAMP

CONSULTANTS:

321 4 5 6 7 8 9 10

5/8/2023 1:06:23 PM

REPLACE DAMAGED

FLOORING

05/11/2023

COMPOSITE AND PHASING PLAN -

SEVENTH FLOOR

GC107

AHSS

539-23-202

CINCINNATI MEDICAL CENTER

VA Station No:

BID DOCUMENTS

N Scale: 1/16" = 1'-0"

SEVENTH FLOOR PLAN

FD

DEMOLITION KEY NOTES

REMOVE EXISTING WALL CONSTRUCTION AS

SHOWN. PATCH & REPAIR ADJACENT SURFACES TO

REMAIN AS NECESSARY TO PREPARE FOR NEW

CONSTRUCTION AND/OR NEW FINISHES.

REMOVE EXISTING DOOR(S), FRAME(S), HARDWARE,

ETC. TURN OVER TO OWNER UNLESS DIRECTED

OTHERWISE.

REMOVE EXISTING TOILET ACCESSORIES AND ALL

WALL MOUNTED EQUIPMENT. TURN OVER TO

OWNER UNLESS DIRECTED OTHERWISE. PATCH AND

REPAIR EXPOSED SURFACES TO REMAIN AS

REQUIRED TO RECEIVE NEW CONSTRUCTION AND

FINISHES.

REMOVE EXISTING WALL FINISHES, WALL BASE, AND

ALL ITEMS ATTACHED TO THE WALLS. TURN OVER TO

OWNER, UNLESS DIRECTED OTHERWISE. PATCH &

REPAIR EXPOSED SURFACES TO REMAIN AS

REQUIRED FOR NEW CONSTRUCTION AND/OR NEW

FINISHES.

REMOVE EXISTING FLOORING AND WALL BASE

INCLUDING ALL ADHESIVES, SETTING MATERIALS

DOWN TO EXISTING SUBSTRATE. GRIND CONCRETE

FLOORS AS REQUIRED TO PROVIDE A SMOOTH AND

UNIFORM SURFACE FOR NEW FINISHES.

REMOVE EXISTING MECHANICAL, PLUMBING &

ELECTRICAL ITEMS - REFER TO MECHANICAL,

PLUMBING & ELECTRICAL DEMOLITION PLANS FOR

FURTHER INFORMATION. PATCH AND REPAIR

EXPOSED SURFACES TO REMAIN AS REQUIRED TO

RECEIVE NEW CONSTRUCTION AND FINISHES.

ABATE & REMOVE ALL EXISTING FLOOR TILE AND

MASTIC. GRIND CONCRETE FLOORS AS REQUIRED

TO PROVIDE A SMOOTH & UNIFORM SURFACE FOR

NEW FINISHES. DISPOSE OF MATERIALS IN

ACCORDANCE TO SPECIFICATIONS.

ABATE & REMOVE EXISTING ASBESTOS INSULATION

ON PIPES TO BE DEMOLISHED. DISPOSE OF

MATERIALS IN ACCORDANCE TO SPECIFICATIONS.

ABATE & REMOVE EXISTING LEAD WALL PAINT.

CONTRACTOR SHALL PATCH & REPAIR SURFACES TO

REMAIN AS REQUIRED TO RECEIVE NEW FINISHES.

DISPOSE OF MATERIALS IN ACCORDANCE TO

SPECIFICATIONS

H1

H2

HAZARDOUS MATERIALS

DEMOLITION NOTES

H3

GENERAL DEMO NOTES

1. ALL DEMOLITION WORK REQUIRED IS NOT NECESSARILY LIMITED

TO WHAT IS SHOWN ON THE DEMOLITION PLANS. THE INTENT IS

TO REMOVE ALL MATERIALS AND ITEMS AS REQUIRED TO

FACILITATE INSTALLATION OF NEW FLOORING FINISHES.

2. CONTRACTORS ARE TO VERIFY FIELD CONDITIONS, IF

CONDITIONS DO NOT REFLECT WHAT IS NOTED IN THE

CONTRACT DOCUMENTS, THE CONTRACTOR IS TO NOTIFY THE

ARCHITECT.

3. THIS PLAN IS TO BE USED IN CONJUNCTION WITH THE ENTIRE SET

OF CONSTRUCTION DOCUMENTS. DO NOT REMOVE ANY ITEMS

WITHOUT VERIFYING AND COORDINATING WITH ALL GENERAL

TRADES AS TO HOW THEY RELATE TO THE OVERALL PROJECT.

4. CONTRACTOR IS RESPONSIBLE FOR PROVIDING DUMPSTERS.

LOCATION OF DUMPSTERS TO BE DETERMINED BY VA COR.

5. CONTRACTOR SHALL REMOVE AND DISPOSE OF ALL

DEMOLISHED MATERIALS. DO NOT ALLOW MATERIALS AND

DEBRIS GENERATED BY DEMOLITION ACTIVITIES TO

ACCUMULATE ON THE JOBSITE. REMOVE DAILY AND DISPOSE

OF IN A LEGAL MANNER. NO ONSITE SALE OR BURNING OR

REMOVED ITEMS IS PERMITTED.

6. THE CONTRACTOR MUST TAKE ALL NECESSARY PRECAUTIONS

TO ENSURE THE SAFETY OF THE PUBLIC AND/OR WORKMEN ON

THE SITE TO PREVENT ACCIDENTS OR INJURY TO ANY PERSON

ON, ABOUT OR ADJACENT TO THE PREMISES. THE CONTRACTOR

SHALL COMPLY WITH ALL LAWS, ORDINANCES, CODES AND

REGULATIONS PERTAINING TO SAFETY AND THE PREVENTION OF

ACCIDENTS.

7. THE CONTRACTOR MUST MAINTAIN ADEQUATE SUPPORT,

INSULATION, WATERPROOFING, EMERGENCY LIGHTING,

SECURITY, ALARMS, ETC. FOR ALL OR PART OF ITEMS WHICH

ARE TO REMAIN.

8. THE OWNER RESERVES THE RIGHTS TO ANY REMOVED

EQUIPMENT. CONTRACTOR TO COORDINATE WITH VA COR.

9. DO NOT CUT AND/OR PATCH STRUCTURAL ELEMENTS IN A

MANNER THAT COULD CHANGE THEIR LOAD-CARRYING

CAPACITY OR LOAD-DEFLECTION RATIO.

10. PATCH/REPAIR OR REPLACE ALL AREAS DAMAGED BY

DEMOLITION, REWORK AS REQUIRED, PREPARE FOR NEW

CONSTRUCTION AS REQUIRED.

11. WHERE WALLS & CEILINGS ARE TO BE REMOVED, ALL ITEMS

THAT FALL WITH THE WALLS &/OR CEILINGS ARE TO BE

REMOVED OR REROUTED. REFER TO MECHANICAL, ELECTRICAL,

AND PLUMBING PLANS FOR ADDITIONAL DEMOLITION NOT

SHOWN ON THIS SHEET.

12. IF HAZARDOUS MATERIALS ARE ENCOUNTERED DURING

DEMOLITION, CONTRACTOR SHALL CONTACT VA COR FOR

ABATEMENT.

13. REMOVE, REPLACE, PATCH, AND REPAIR MATERIALS AND

SURFACES CUT OR DAMAGED DURING DEMOLITION, BY

METHODS AND WITH MATERIALS SO AS NOT TO VOID EXISTING

WARRANTIES.

14. CLEAN AREAS AND SPACES WHERE CUTTING AND PATCHING

ARE PERFORMED.

15. INTERIOR WALLS TO BE REMOVED, SHALL BE REMOVED THE

ENTIRE HEIGHT OF THE WALL UNLESS REQUIRED OTHERWISE BY

NEW OPENINGS IN EXISTING WALLS TO REMAIN.

16. CONTRACTOR SHALL PATCH, REPAIR, AND INFILL ALL APPLIED

FIREPROOFING MATERIAL IN AREAS LEFT UNPROTECTED DUE TO

REMOVAL OF EXISTING ELEMENTS OR AREAS DAMAGED

DURING NEW WORK AND DEMOLITION. MATCH EXISTING

FIREPROOFING MATERIAL TYPE AND THICKNESS TO MAINTAIN

REQUIRED LEVEL OR PROTECTION.

1020 SF

C002

MEDICAL RECORDS

STORAGE

H1

105 SF

C037A

AUD. BOOTH

102 SF

C037

AUD. BOOTH

186 SF

A144

DECEDENT AFFAIRS

198 SF

A144A

CONF. ROOM

116 SF

B135

OFF.5

H1

70 SF

A251

STUDENT OFF.

H1

177 SF

A257

READING ROOM

135 SF

A258

READING ROOM

130 SF

A259

ADM.

188 SF

A260

CHIEF RADIOLOGY

199 SF

A261

ADM. ASST.

141 SF

A262

OFF.

117 SF

A264

READING ROOM

105 SF

A262A

READING ROOM

H1

H1

116 SF

A263

RESIDENT READING

ROOM

114 SF

A256

VIEWING

H1

149 SF

A321

CHIEF OFF.

H1

138 SF

A347

VASC. LAB

H2

H3

H1

18 SF

A347A

TLT.

162 SF

A353

OFF.

607 SF

B326

FAMILY WAITING

151 SF

B327

RECEPTION

151 SF

C314

ICU DIR. OFF.

148 SF

A300

VASC. LAB

256 SF

A301

OFFICE

145 SF

A302

CHIEF DIET.

146 SF

A303

DIET SEC.

277 SF

A379

VASC. LAB

5 5 5 5 5

H1H1

427 SF

C3002

WAITING

77 SF

C360

EMS

124 SF

C3005

CONSULT.

19 SF

C3005A

130 SF

A422A

SOCIAL WORKER

157 SF

A755

OFFICE #8

H1

76 SF

A770

TESTING

5146 SF

A775

OFFICE #18

H1

5114 SF

B711

OFF.

H1

VA Project No.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

STAMP

CONSULTANTS:

321 4 5 6 7 8 9 10

5/8/2023 1:06:25 PM

REPLACE DAMAGED

FLOORING

05/11/2023

INTERIOR DEMOLITION PLANS

ID100

AHSS

539-23-202

CINCINNATI MEDICAL CENTER

VA Station No:

BID DOCUMENTS

SCALE: 1/8" = 1'-0"ID100

DEMOLITION PLAN - C00201

SCALE: 1/8" = 1'-0"ID100

DEMOLITION PLAN - C037/C037A02

SCALE: 1/8" = 1'-0"ID100

DEMOLITION PLAN - A144/A144A03

SCALE: 1/8" = 1'-0"ID100

DEMOLITION PLAN - B13504

SCALE: 1/8" = 1'-0"ID100

DEMOLITION PLAN - A25105

SCALE: 1/8" = 1'-0"ID100

DEMOLITION PLAN - A257-A26412

SCALE: 1/8" = 1'-0"ID100

DEMOLITION PLAN - A32106

SCALE: 1/8" = 1'-0"ID100

DEMOLITION PLAN - A347/A347A07

SCALE: 1/8" = 1'-0"ID100

DEMOLITION PLAN - A35308

SCALE: 1/8" = 1'-0"ID100

DEMOLITION PLAN - B326/B32711

SCALE: 1/8" = 1'-0"ID100

DEMOLITION PLAN - C31409

SCALE: 1/8" = 1'-0"ID100

DEMOLITION PLAN - A300-A37913

Revisions Date

SCALE: 1/8" = 1'-0"ID100

DEMOLITION PLAN - C300210

SCALE: 1/8" = 1'-0"ID100

DEMOLITION PLAN - C36014

SCALE: 1/8" = 1'-0"ID100

DEMOLITION PLAN - C300515

SCALE: 1/8" = 1'-0"ID100

DEMOLITION PLAN - A422A16

SCALE: 1/8" = 1'-0"ID100

DEMOLITION PLAN - A75517

SCALE: 1/8" = 1'-0"ID100

DEMOLITION PLAN - A77018

SCALE: 1/8" = 1'-0"ID100

DEMOLITION PLAN - A77519

SCALE: 1/8" = 1'-0"ID100

DEMOLITION PLAN - B71120

SUBSTRATE. PREP PER

MANUF.

RECOMMENDATIONS

RESILIENT TRANSITION

STRIP; COLOR TO

MATCH ADJACENT

WALL BASE

EXISITNG CARPET TILE

RESILIENT FLOORING;

SEE FINISH SCHEDULE

AND KEY

RESILIENT REDUCER

STRIP, COLOR TO

MATCH ADJACENT

WALL BASE

RESILIENT FLOORING,

SEE FINISH KEY

EXISTING FLOORING

SUBSTRATE. PREP PER

MANUF.

RECOMMENDATIONS

SUBSTRATE. PREP PER

MANUF.

RECOMMENDATIONS

RESILIENT TRANSITION

STRIP; COLOR TO

MATCH ADJACENT

WALL BASE

EXISTING RESILIENT

FLOORING

RESILIENT TILE; SEE

FINISH KEY

LUXURY VINYL TILE; SEE

FINISH SCHEDULE & KEY

EXISTING METAL

TRANSITION PIECE

EXISITNG PORCELAIN

FLOOR TILE

SUBSTRATE, PREP PER

MANUF.

RECOMMENDATIONS

VA Project No.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

STAMP

CONSULTANTS:

321 4 5 6 7 8 9 10

5/8/2023 1:06:27 PM

REPLACE DAMAGED

FLOORING

05/11/2023

FINISH KEY & DETAILS

IN100

AHVG

539-23-202

CINCINNATI MEDICAL CENTER

VA Station No:

BID DOCUMENTS

SCALE: 12" = 1'-0"IN100

CARPET TILE TO RESILIENT TILE FLOORING01

SCALE: 12" = 1'-0"IN100

RESILIENT FLOORING REDUCER02

SCALE: 12" = 1'-0"IN100

RESILENT TILE TO EXISTING03

INTERIOR FINISH KEY

TAG MATERIAL MANUFACTURER STYLE COLOR REMARKS

09 65 13 RESILIENT BASE AND ACCESSORIES

RWB-1 RUBBER WALL BASE JOHNSONITE MW-XX-F8 MILLWORKS MANDALAY FAWN 80 8" HIGH, CORRIDORS AND WAITING ROOMS

RWB-2 RUBBER WALL BASE JOHNSONITE RUBBER COVE BASE FAWN 80 4" HIGH, OFFICES AND ADMINISTRATIVE

RWB-3 RUBBER WALL BASE JOHNSONITE RUBBER COVE BASE FAWN 80 6" HIGH, PATIENT CARE AREAS

09 65 19 RESILIENT TILE FLOORING

RTF-1 RESILIENT TILE FLOORING TARKETT ID LATITUDE WOOD 3307 EUROPEAN CHERRY

09 91 00 PAINTING

PT-1 PAINT BENJAMIN MOORE INTERIOR ACRYLIC LATEX - LOW VOC LRV:70 WIND'S BREATH 981 WALLS - GLOSS LEVEL 3 - EGGSHELL

PT-2 PAINT BENJAMIN MOORE INTERIOR ACRYLIC LATEX - LOW VOC LRV:70 WIND'S BREATH 981 CEILING - GLOSS LEVEL 1 - FLAT

SCALE: 12" = 1'-0"IN100

PORCELAIN TILE TO RESILIENT TILE FLOORING04

FD

MEDICAL

RECORDS

STORAGE

C002

RTF-1

RWB-2

IN100

IN100

NOTE:

EXISTING RESILIENT

TILE FLOORING TO

REMAIN

AUD. BOOTH

C037A

RTF-1

RWB-3

AUD. BOOTH

C037

RTF-1

RWB-3

DECEDENT

AFFAIRS

A144

RTF-1

RWB-2

CONF. ROOM

A144A

RTF-1

RWB-2

IN100

IN100

OFF.

B135

RTF-1

RWB-2

IN100

STUDENT OFF.

A251

RTF-1

RWB-2

IN100

CHIEF OFF.

A321

RTF-1

RWB-2

IN100

READING

ROOM

A257

RTF-1

RWB-2

READING

ROOM

A258

RTF-1

RWB-2

ADM.

A259

RTF-1

RWB-2

CHIEF

RADIOLOGY

A260

RTF-1

RWB-2

ADM. ASST.

A261

RTF-1

RWB-2

OFF.

A262

RTF-1

RWB-2

READING

ROOM

A264

RTF-1

RWB-2

READING

ROOM

A262A

RTF-1

RWB-2

IN100

RESIDENT

READING

ROOM

A263

RTF-1

RWB-2

VIEWING

A256

RTF-1

RWB-2

VASC. LAB

A347

RTF-1

RWB-3

PT-1

PT-2

IN100

IN100

IN100

PATCH GYP. BD. WHERE

EXISTING WALLS ARE

REMOVED TO PREP FOR

NEW PAINT FINISH

OFF.

A353

RTF-1

RWB-2

IN100

FAMILY

WAITING

B326

RTF-1

RWB-1

RECEPTION

B327

RTF-1

RWB-2

IN100

ICU DIR. OFF.

C314

RTF-1

RWB-2

IN100

FINISH PLAN LEGEND

ROOM NAMEOFFICE

XXXX

RTF-1

RWB-1

ROOM NUMBER

FLOOR FINISH

BASE FINISH

GENERAL NOTE

1. REFER TO INTERIOR FINISH KEY & DETAILS ON SHEET IN100.

2. CONTINUE ALL NEW INTERIOR FINISHS INTO ADJACENT

CLOSETS, ETC.

3. TRANSITIONS BETWEEN DIFFERENT HEIGHT FLOORING

MATERIALS REQUIRE AN ADA-COMPLIANT RESILIENT

TRANSITION STRIP.

4. CONTINUE RESILIENT WALL BASE AROUND ALL CASEWORK

BASE/TOE-KICKS U.N.O.

FLOORING TRANSITION

VASC. LAB

A300

RTF-1

RWB-3

OFFICE

A301

RTF-1

RWB-2

CHIEF DIET.

A302

RTF-1

RWB-2

DIET SEC.

A303

RTF-1

RWB-2

VASC. LAB

A379

RTF-1

RWB-3

IN100

IN100

IN100

IN100

IN100

EMS

C360

RTF-1

RWB-2

IN100

CONSULT.

C3005

RTF-1

RWB-2

C3005A

RTF-1

RWB-2

IN100

WAITING

C3002

RTF-1

RWB-1

IN100

IN100

SOCIAL

WORKER

A422A

RTF-1

RWB-2

IN100

OFFICE #8

A755

RTF-1

RWB-2

IN100

TESTING

A770

RTF-1

RWB-2

IN100

OFFICE #18

A775

RTF-1

RWB-2

IN100

OFF.

B711

RTF-1

RWB-2

IN100

VA Project No.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

STAMP

CONSULTANTS:

321 4 5 6 7 8 9 10

5/8/2023 1:06:28 PM

REPLACE DAMAGED

FLOORING

05/11/2023

FINISH PLANS

IN101

AHVG

539-23-202

CINCINNATI MEDICAL CENTER

VA Station No:

BID DOCUMENTS

SCALE: 1/8" = 1'-0"IN101

FINISH PLAN - C00201

SCALE: 1/8" = 1'-0"IN101

FINISH PLAN - C037/C037A02

SCALE: 1/8" = 1'-0"IN101

FINISH PLAN - A144A03

SCALE: 1/8" = 1'-0"IN101

FINISH PLAN - B13504

SCALE: 1/8" = 1'-0"IN101

FINISH PLAN - A25105

SCALE: 1/8" = 1'-0"IN101

FINISH PLAN - A32106

SCALE: 1/8" = 1'-0"IN101

FINISH PLAN - A257-A26413

SCALE: 1/8" = 1'-0"IN101

FINISH PLAN - A34707

SCALE: 1/8" = 1'-0"IN101

FINISH PLAN - A35308

SCALE: 1/8" = 1'-0"IN101

FINISH PLAN - B326/B32712

SCALE: 1/8" = 1'-0"IN101

FINISH PLAN - C31409

Revisions Date

SCALE: 1/8" = 1'-0"IN101

FINISH PLAN - A300-A37911

SCALE: 1/8" = 1'-0"IN101

FINISH PLAN - C36010

SCALE: 1/8" = 1'-0"IN101

FINISH PLAN - C300515

SCALE: 1/8" = 1'-0"IN101

FINISH PLAN - C300214

SCALE: 1/8" = 1'-0"IN101

FINISH PLAN - A422A16

SCALE: 1/8" = 1'-0"IN101

FINISH PLAN - A75517

SCALE: 1/8" = 1'-0"IN101

FINISH PLAN - A77018

SCALE: 1/8" = 1'-0"IN101

FINISH PLAN - A77519

SCALE: 1/8" = 1'-0"IN101

FINISH PLAN - B71120

B R A D E N S .

C O X

6201070323

NO.

ENGINEER

S T

A

T E

O F M I C H

I

G A

N

R E

E N

I G

N

E

LANOISSEFORP

D

E S

N E

C I

L

WM

M

S

M

CHWS

CWV

CA

CD

CDR

CWR

CWS

CW

F-CW

H-CW

S-CW

HW

HW 140°

HW-R

HW-R 140°

GV

GW

HWR

HWS

G

OV

OW

PD

V

SS

SHWR

SHWS

STM

SD

OSD

(E)

CHWR CHILLED WATER RETURN

CHILLED WATER SUPPLY

COMBINATION WASTE & VENT

COMPRESSED AIR

CONDENSATE DRAINAGE

CONDENSATE RETURN

CONDENSER WATER RETURN

CONDENSER WATER SUPPLY

DOMESTIC COLD WATER

FILTERED COLD WATER

HARD COLD WATER

SOFT COLD WATER

HOT WATER

HOT WATER 140°

HOT WATER RECIRCULATION

HOT WATER RECIRCULATION 140°

GREASE VENT

GREASE WASTE

HEATING WATER RETURN

HEATING WATER SUPPLY

NATURAL GAS

OIL VENT

OIL WASTE

PUMP DISCHARGE

SANITARY VENT

SANITARY SEWER

SOLAR HOT WATER RETURN

SOLAR HOT WATER SUPPLY

STEAM

STORM DRAINAGE

OVERFLOW STORM DRAINAGE

REF-L

REF-S

REFRIGERANT-LIQUID

REFRIGERANT-SUCTION

2"

4"

REF-HG REFRIGERANT-HOT GAS

PLUMBING AND PIPING SYMBOLS

KEYNOTE

CONTINUATION SYMBOL

NUMBER OF SHEET WHERE DETAIL APPEARS

NUMBER OF DETAIL ON SHEET

REVISION NUMBER - SHOWN ON PLANS

GENERAL SYMBOLS

ROOM NAME AND NUMBER

POINT WHERE DISCONNECT/DEMOLITION OCCURS

AT EXISTING

EXISTING PIPE TAG

ITEM TO BE DEMOLISHED

AREA NOT IN CONTRACT

PIPING BEING DEMOLISHED

ABOVE GROUND PIPING

PIPE SIZE TAG (DIAMETER)

BELOW GROUND PIPING

PIPE INVERT ELEVATION TAG

PG PROPANE GAS

Room

1/8" / 12" SLOPE

RO REVERSE OSMOSIS WATER

IW INDIRECT WASTE

0 SF

6" SD-1

Ø ROUND

ABV ABOVE

AC AIR CONDITIONING

AD AREA DRAIN

ADD ADDENDUM

AFF ABOVE FINISHED FLOOR

AFUE ANNUAL FUEL UTILIZATION

EFFICIENCY

ALT ALTERNATE

AP ACCESS PANEL

ARCH ARCHITECT/ARCHITECTURAL

BFF BELOW FINISHED FLOOR

BLW BELOW

BTU BRITISH THERMAL UNITS

BTUH BRITISH THERMAL UNITS PER

HOUR

CAP CAPACITY

CB CATCH BASIN

CFM CUBIC FEET PER MINUTE

CLG CEILING

CO CLEAN OUT

CW COLD WATER

D DEGREE

DB DRY BULB

DIA DIAMETER

DN DOWN

DW DISTILLED WATER

EA EACH

EAT ENTERING AIR TEMPERATURE

ELEC ELECTRICAL

EQUIP EQUIPMENT

EWC ELECTRIC WATER COOLER

EWT ENTERING WATER TEMPERATURE

E/A EXHAUST AIR

EXIST EXISTING

F DEGREES FAHRENHEIT

FCO FLOOR CLEAN OUT

FD FLOOR DRAIN

FDC FIRE DEPARTMENT CONNECTION

FL FLOOR

FO FUEL OIL

FOV FUEL OIL VENT

FOR FUEL OIL RETURN

FOS FUEL OIL SUPPLY

FPM FEET PER MINUTE

FS FLOOR SINK

FT FOOT/FEET

FTR FIN TUBE RADIATION

GAL GALLON

GF GAS-FIRED

GC GENERAL CONTRACTOR

GPM GALLONS PER MINUTE

GW GREASE WASTE

HB HOSE BIB

HP HORSE POWER

HTG HEATING

HTR HEATER

HW HOT WATER

HYD HYDRANT

ID INDIRECT

IN INCH

INV INVERT

LB POUND

LB/HR POUNDS PER HOUR

LAT LEAVING AIR TEMPERATURE

LP LOW PRESSURE

LPG LIQUEFIED PETROLEUM GAS

LVR LOUVER

LWT LEAVING WATER

TEMPERATURE

M/A MIXED AIR

MAX MAXIMUM

MBH ONE THOUSAND BTU PER

HOUR

MCF ONE THOUSAND CUBIC FEET

MD MOTORIZED DAMPER

MECH MECHANICAL

MFR MANUFACTURER

MIN MINIMUM

MISC MISCELLANEOUS

MTR MOTOR

MU/A MAKE-UP/AIR

NC NOISE CRITERIA

NC NORMALLY CLOSED

NIC NOT IN CONTRACT

NO NUMBER

NO NORMALLY OPEN

NTS NOT TO SCALE

O OXYGEN

O/A OUTSIDE AIR

ORD OVERFLOW ROOF DRAIN

PD PRESSURE DROP

PIV POST INDICATOR VALVE

PLBG PLUMBING

PRESS PRESSURE

PRV PRESSURE REDUCING VALVE

PSI POUNDS PER SQUARE INCH

PSIG POUNDS PER SQUARE INCH

GAUGE

PWR POWER

R DUCT RISER

R/A RETURN AIR

RCP RADIANT CEILING PANEL

RD ROOF DRAIN

REC RECESSED

RED REDUCER

RH RELATIVE HUMIDITY

RL/A RELIEF AIR

RM ROOM

RPM REVOLUTIONS PER MINUTE

RW RAIN WATER

SF SQUARE FOOT

S/A SUPPLY AIR

SAN SANITARY

SF SQUARE FOOT

SD SMOKE DAMPER

SM SURFACE MOUNT

SP STANDPIPE

SP STATIC PRESSURE

STM STEAM

T THERMOSTAT

TD TEMPERATURE DROP

TDR TRENCH DRAIN

TEMP TEMPERATURE

TYP TYPICAL

UG UNDERGROUND

VAC VACUUM

V VENT

VAV VARIABLE AIR VOLUME

VENT VENTILATION

VTR VENT THROUGH ROOF

W WASTE

WB WET BULB

WCO WALL CLEAN OUT

WH WALL HYDRANT

ABBREVIATIONS

AC AIR CONDITIONING UNIT

ACCU AIR COOLING CONDENSING

UNIT

AHU AIR HANDLING UNIT

AS AIR SEPARATOR

B BOILER

CH CHILLER

CT COOLING TOWER

CUH CABINET UNIT HEATER

CHWP CHILLED WATER PUMP

DBP DOMESTIC WATER BOOSTER PUMP

DC DUCT MOUNTED COIL

DCP DOMESTIC WATER CIRCULATING

PUMP

EF EXHAUST FAN

EDC ELECTRIC DUCT COIL

ET EXPANSION TANK

EWH ELECTRIC WATER HEATER

FCU FAN COIL UNIT

FP FIRE PUMP

GI GREASE INTERCEPTOR

GRV GRAVITY ROOF

VENTILATOR

HWP HEATING WATER PUMP

HRU HEAT RECOVERY UNIT

PRV POWER ROOF VENTILATOR

RE RETURN/EXHAUST FAN

RTU ROOFTOP UNIT

SP SUMP PUMP

UH UNIT HEATER

WH WATER HEATER

EQUIPMENT ABBREVIATIONS

4" FD-1FLOOR DRAIN 4" AD-6 AREA DRAIN

4" FS-4FLOOR SINK

4" SD-29 DECK DRAIN4" FD-3PFLOOR DRAIN

6 DFU

4" FD-13

HUB DRAIN

DRAIN TAGS

FIXTURE

UNITS

FLOW

CONTROL

DRAIN

4" SD-12

COMBINATION

DRAINS

STORM DRAIN4" SD-15

PIPE ACCESSORY TAGS

DOMESTIC WATER METER

BALANCING VALVE

1/4 TURN BALL VALVE

CHECK VALVE

3-WAY MIXING VALVE

MOTORIZED CONTROL VALVE

3 WAY MOTORIZED CONTROL

VALVE

PRESSURE REDUCING VALVE

REFRIGERANT SOLENOID

VALVE

BUTTERFLY VALVE

2" BUTTERFLY

WATER CLOSET

- WALL HUNG -

ADA

WC-1

U-1

PLUMBING FIXTURE TAGS

TYPE (SEE SCHEDULE)

WC-1A

CAP

GWR

GWS

GEOTHERMAL WATER RETURN

GEOTHERMAL WATER SUPPLY

GATE VALVE

P

3-WAY AIRMOTOR

CONTROLLER

ANGLE GLOBE VALVE

ANGLE HOSE VALVE

DIAPHRAGM VALVE

GLOBE VALVE

S

HOSE GLOBE VALVE

LOCK SHIELD VALVE

NEEDLE VALVE

PLUG VALVE

QUICK OPENING VALVE

SPRING CHECK VALVE

SWING GATE CHECK VALVE

TEMP PRESSURE RELIEF VALVE

* NOTE *

ALL GENERAL NOTES ON THIS SHEET ARE TO BE APPLIED TO ALL OTHER DRAWINGS

IN THIS SET. THE SYMBOLS AND ABBREVIATIONS SHOWN ON THIS SHEET MAY OR

MAY NOT BE USED IN THIS SET OF DRAWINGS.

POINT WHERE NEW CONNECTS TO EXISTING

(D)

2"

4"

DRAIN SIZE

PIPE RISE

PIPE DROP

PIPE TEE REDUCING 45

DEGREE TEE

DEGREE

TEE

PIPE SLOPE TAG

TYPE (SEE SCHEDULE)

INVERT: -105' - 1"

"P" - INDICATES

PRIMER

CONNECTION

ROOF AREA SERVED BY DRAIN

2" DOM. WM

2" BALANCING

2" SHUTOFF

2" CHECK

2" TMV

2" M-CONTROL

2" 3-WAY CONTROL

2" PRV

3/8" SOLENOID

2" BUTTERFLY

1 DFU

LAVWA

0.75 CWFU

0.75 HWFU

LAVWA

FIXTURE UNITS

PIPE

ACCESSORY

TAG

TYPE (SEE SCHEDULE)

CAP

WCO

PLUGH

H

I

I

6 6

7 7

8a 8a

9 9

Jb

Jb

8 8

VASC. LAB

A347

GENERAL PROJECT NOTES

1 REMOVE ALL UNUSED PIPING, DUCTWORK AND ACCESSORIES.

2 THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING,

PRIOR TO FINAL BID, ALL EXISTING CONDITIONS FOR PLUMBING AND

MECHANICAL SYSTEMS WITHIN TENANT SPACE AND WITHIN CLOSE PROXIMITY OF

TENANT SPACE.

3 THE MECHANICAL CONTRACTOR SHALL VISIT THE SITE, PRIOR TO FINAL BIDDING,

AND VERIFY ALL EXISTING SITE CONDITIONS. PROVIDE ALL MATERIAL AND

COMPONENTS AS NEEDED TO BRING THE UNITS TO FULL COMPLIANCE OF THE

OWNER'S CRITERIA AND LOCAL AUTHORITY HAVING JURISDICTION.

4 WHERE FLOOR DRAINS OCCUR WITHIN THE LIMITS OF CONSTRUCTION, PREVENT

CONSTRUCTION DEBRIS FROM ENTERING DRAIN BODY BY SEALING DRAIN

OPENING PRIOR TO START OF WORK. UNSEAL DRAINS AT COMPLETION OF

CONSTRUCTION.

5 THE CONTRACTOR SHALL BE FAMILIAR WITH ALL THE CONDITIONS BOTH EXISTING

AND THOSE ILLUSTRATED BY THESE DOCUMENTS AS WELL AS THOSE WHICH CAN

BE REASONABLY ANTICIPATED INCLUDING, BUT NOT LIMITED TO ARCHITECTURAL,

ELECTRICAL, VENTILATION, PLUMBING, AND OTHER SYSTEMS INVOLVED ON THIS

PROJECT.

6 FINAL PRODUCT SHALL BE A COMPLETE AND FUNCTIONING SYSTEM, AND SHALL

CONFORM TO ALL REQUIREMENTS OF APPLICABLE FEDERAL, STATE, AND LOCAL

CODES, INCLUDING BUT NOT LIMITED TO THE INTERNATIONAL BUILDING CODE

AND INTERNATIONAL MECHANICAL CODE.

7 LOCATE DUCTWORK, PIPING AND MECHANICAL EQUIPMENT AWAY FROM THE

SPACE ABOVE ELECTRICAL PANELS. TRANSFORMERS AND OTHER ELECTRICAL

EQUIPMENT.

8 PENETRATIONS OF RATED ASSEMBLIES SHALL BE FIRE STOPPED. FIRE STOPPING

SHALL BE AN APPROVED MATERIAL AS PRESCRIBED IN CSFM STANDARD 43-1

AND SHALL BE U.L. LISTED.

9 MAINTAIN CLEAR ACCESS TO SERVICE EQUIPMENT AND OTHER ACCESSORIES

REQUIRING SERVICE, VISUAL INSPECTION OR HAND OPERATION. WHERE

INDICATED OR REQUIRED, PROVIDE ACCESS PANELS OF THE TYPE SELECTED TO

SUIT MATERIALS IN WHICH INSTALLED.

10 INSTALL ALL EQUIPMENT IN ACCORDANCE WITH THE RESPECTIVE

MANUFACTURER'S WRITTEN INSTALLATION INSTRUCTIONS, AT A LEVEL OF QUALITY

AND WORKMANSHIP CONSISTENT WITH THE SPECIFICATIONS.

11 LOCATIONS OF PIPING, DUCTWORK AND EQUIPMENT AS INDICATED ON THE

DRAWING, ARE APPROXIMATE AND SUBJECT TO MINOR ADJUSTMENTS IN THE

FIELD. WORK SHALL BE COORDINATED WITH ALL OTHER TRADES TO AVOID

INTERFERENCE IN THE FIELD.

12 THE CONTRACTOR'S WORK SCHEDULE SHALL BE SUBMITTED TO AND APPROVED

BY THE OWNER.

13 PRIOR TO STARTING WORK, SUBMIT SHOP DRAWINGS FOR ALL MECHANICAL

EQUIPMENT, PLUMBING FIXTURES, AND DIFFUSERS.

14 CONTRACTOR SHALL OBTAIN AND PAY FOR ALL NECESSARY PERMITS AND SHALL

ARRANGE FOR ALL INSPECTIONS AS REQUIRED.

15 PROVIDE ONE YEAR WARRANTY FOR ALL WORKMANSHIP AND MATERIALS AFTER

THE DATE OF FINAL ACCEPTANCE.

16 EACH DETAIL INCLUDED IN THIS SET OF DOCUMENTS APPLIES TO THIS PROJECT

REGARDLESS IF EACH DETAIL HAS BEEN REFERENCED ON THE PLANS OR NOT.

GENERAL PLUMBING NOTES

1 FIELD VERIFY ALL NEW WATER, WASTE, AND VENT PIPING CONNECTIONS AND

PROVIDE NEW CONNECTIONS AS REQUIRED FOR PROPERLY OPERATING

SYSTEMS.

PLUMBING SHEET LIST

SHEET DESCRIPTION

P001 PLUMBING GENERAL INFO & SYMBOL LEGEND, AND THIRD FLOOR

DEMOLITION PLAN

VA Project No.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

STAMP

CONSULTANT

321 4 5 6 7 8 9 10

REPLACE DAMAGED

FLOORING

5/11/2023

PLUMBING GENERAL INFO &

SYMBOL LEGEND, AND THIRD

FLOOR DEMOLITION PLAN

P001

SMBC

539-23-202

CINCINNATI MEDICAL CENTER

VA Station No:

BID DOCUMENTS

NORTH

SCALE: 1/4" = 1'-0"

THIRD FLOOR PLUMBING DEMOLITION PLAN

KEYNOTES

1 REMOVE EXISTING WATER CLOSET AND ASSOCIATED PIPING

BACK TO MAIN AND CAP.

PLUMBING DEMOLITION NOTES

1 THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE

LOCAL, STATE AND/OR REGULATORY AGENCIES, CODES AND

REGULATIONS FOR NEW WORK.

2 CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION

OF THEIR WORK WITH OTHER TRADES AND WITH THE

CONSTRUCTION MANAGER.

3 VERIFY ALL CONDITIONS IN FIELD BEFORE START OF

CONSTRUCTION. NOTIFY ARCHITECT/ENGINEER OF

DISCREPANCIES BETWEEN DRAWINGS AND ACTUAL FIELD

CONDITIONS.

4 COORDINATE ALL WORK WITH APPROPRIATE TRADES.

5 COORDINATE ANY REQUIRED SHUTDOWN OF SERVICES OR

EQUIPMENT WITH OWNER'S REPRESENTATIVE, MINIMIZE

INTERRUPTION OF EXISTING SERVICES. VERIFY ALL SYSTEMS

BEFORE STARTING DEMOLITION TO ASSURE OTHER AREAS WILL

NOT LOOSE SERVICE. AREAS SUCH AS THE SECOND FLOOR

KITCHEN ARE CRITICAL TO THE FACILITIES OPERATION.

6 COORDINATE FLOOR, WALL, AND ROOF PENETRATIONS ETC.

WITH ARCHITECTURAL TRADES. PROVIDE TEMPORARY WATER

TIGHT SEAL FOR ALL EXTERIOR WALL AND ROOF PENETRATION

AS NECESSARY.

7 COORDINATE ALL FLOOR CUTTING WITH STRUCTURAL TRADES

BEFORE CUTTING.

8 HOLES AND PENETRATIONS IN RATED WALLS SHALL BE PATCHED

WITH APPROPRIATE FIRESTOP MATERIALS FOR RATING REQUIRED.

9 NO ITEMS ABANDONED IN PLACE.

10 ALL ITEMS DEMOLISHED SHALL BE REMOVED AND REMAINING

OPEN SYSTEMS SHALL BE PATCHED, CAPPED AND SEALED TO

PROVIDE A FINISHED SYSTEM.

11 DEMOLISHED PLUMBING LINE SHALL NOT BE ALLOWED TO

REMAIN OPEN, CAP AND PROTECT TO AVOID CONTAMINATION

TO AND FROM THE SURROUNDING AREAS.

12 ALL SYSTEMS OPENED DURING DEMOLITION SHALL BE CLOSED

AND RETURNED TO OPERATION BY END OF SHIFT, NO SYSTEMS

ALLOWED TO BE LEFT OPEN WHEN NOT BEING SUPERVISED BY

CONTRACTOR RESPONSIBLE FOR THAT WORK TRADE.

5/10/23

B R A D E N S .

C O X

6201070323

NO.

ENGINEER

S T

A

T E

O F M I C H

I

G A

N

R E

E N

I G

N

E

LANOISSEFORP

D

E S

N E

C I

L

J

K O

S T

T D

D

EM

P

P

J R

E T

H T

F

F

F F

D

F P

FR

L6 -3

CLNG

J

F S

D

V

M

ES

ML

DC

CL

CR

MD

E

B

D

S

P

N

TV

N

N

IG

G

FI

G

FI

W

P

TP U

SB

A C

EW

C

G

FI

OS

XX-1 XX-1 XX-1

XX-1

XX-1

ELECTRICAL SYMBOL NOTES

EXIT LIGHTS. STEM INDICATES WALL MOUNTING. NO STEM INDICATES

CEILING MOUNTING. SHADED AREA INDICATES ILLUMINATED FACE(S).

ARROW INDICATES DIRECTIONAL ARROW ON ILLUMINATED FACE(S).

THE CIRCUIT DESIGNATION IS INDICATED BY A NUMBER. EXAMPLE: THE

WALL MOUNTED EXIT LIGHT TYPE "E1" WITH SINGLE FACE AND

DIRECTIONAL ARROW IS CONNECTED TO CIRCUIT 1.

DEVICES. THE CIRCUIT DESIGNATION IS INDICATED BY A NUMBER.

THE SWITCH DESIGNATION IS INDICATED BY A LOWER CASE LETTER.

EXAMPLE: SPLIT DUPLEX RECEPTACLE IS CONNECTED TO CIRCUIT 1

AND ONE RECEPTACLE OUTLET IS CONTROLLED BY SWITCH "d".

THE CONTROL DEVICE DESIGNATION IS INDICATED BY A LOWER CASE

LETTER. EXAMPLE: SINGLE POLE SWITCH "d" TO CONTROL LIGHTING

FIXTURES INDICATED BY "d".

WALL BOX DIMMER WITH SIZE AS INDICATED AT DEVICE. EXAMPLE: 600

WATT WALL BOX DIMMER TO CONTROL LIGHTING FIXTURES INDICATED

BY "e". SEE SPECIFICATIONS FOR WATTAGE IF NOT INDICATED.

SPECIAL CONNECTIONS. THE EQUIPMENT IS INDICATED BY A NUMBER

IN A CIRCLE. SEE THE MOTOR AND EQUIPMENT SCHEDULE FOR THE

LOAD DESCRIPTION AND TYPE OF CONNECTION. THE CIRCUIT

DESIGNATION IS INDICATED BY NUMBER(S) ADJACENT TO THE SYMBOL.

EXAMPLE: EQUIPMENT NO. ELEC-1; 1 PHASE CONNECTION TO

CIRCUITS 2, 4.

MOTOR CONNECTIONS. THE MOTOR IS INDICATED BY A NUMBER

WITHIN OR CHARACTERS ADJACENT TO THE MOTOR SYMBOL. SEE

THE MOTOR AND EQUIPMENT SCHEDULE FOR THE MOTOR

DESCRIPTION AND ELECTRICAL REQUIREMENTS.

TRANSFORMERS. THE TRANSFORMER TYPE IS INDICATED BY A NUMBER

FOLLOWING THE UPPER CASE LETTER "T". SEE THE TRANSFORMER

SCHEDULE OR THE SINGLE LINE DIAGRAM FOR THE TRANSFORMER

DESCRIPTION AND REQUIREMENTS. EXAMPLE: TRANSFORMER TYPE "T1".

PANELBOARDS. PANELBOARD DOORS MAY BE SHOWN TO

INDICATE OPENING SIDE OF RECESSED PANELBOARDS. SEE

PANELBOARD IDENTIFICATION FOR DESIGNATION CODES.

CONDUIT SHOWN WITHOUT SLASH MARKS SHALL CONTAIN 1 # 12

CONDUCTOR PER PHASE, NEUTRAL, AND GROUND IN 1/2" CONDUIT

UNLESS SPECIFIC EQUIPMENT REQUIRES A DIFFERENT SIZE.

CONDUIT SHOWN SHALL CONTAIN 1 # 10 CONDUCTOR PER PHASE IN

ELECTRICAL CODE SIZED MINIMUM CONDUIT UNLESS A CONDUCTOR

AND CONDUIT SIZE IS SHOWN ADJACENT.

HOME RUN TO BRANCH CIRCUIT PANELBOARD. THE PANELBOARD

DESIGNATION IS SHOWN ADJACENT TO THE HOME RUN ARROW AS A

NUMERATOR AND THE CIRCUIT DESIGNATION IS SHOWN AS THE

DENOMINATOR. CIRCUIT BREAKER SIZES (AMPS/NUMBER OF POLES)

ARE SHOWN IN THE PANELBOARD SCHEDULE WITH THE

CORRESPONDING PANELBOARD AND CIRCUIT DESIGNATION.

EXAMPLE: HOME RUN TO PANELBOARD P4N-102; CIRCUITS 1, 3, 5.

SYMBOLSYMBOL SYMBOLDESCRIPTION DESCRIPTION DESCRIPTION

FIRE ALARM HORN W/STROBE

FIRE ALARM BELL

FIRE ALARM BELL W/STROBE

FIRE ALARM CHIME W/STROBE

THERMOSTAT

HUMIDISTAT

ELECTRONIC TIMER

RELAY

CABLE TAP BOX

SAFETY DISC. SWITCH (FUSED)

SAFETY DISC. SWITCH (NON-FUSED)

COMB. MOTOR STARTER (FUSED)

TRANSFORMER

FLOOR JUNCTION BOX

JUNCTION BOX

UTILITY SERVICE POWER POLE

STATIC GROUND RECEPTACLE

SURGERY SERVICE COLUMN

POWER POLE (OPEN OFFICE STYLE)

MULTIOUTLET ASSEMBLY

RECEPTACLE ON CORD REEL

FLOOR DUPLEX RECEPT.

FOURPLEX RECEPTACLE ON

EMERGENCY CIRCUIT

FOURPLEX RECEPTACLE

SINGLE RECEPT.

PUSH BUTTON

TIME DELAY SWITCH

TIMER SWITCH

OCCUPANCY SENSOR

DIMMER SWITCH

SWITCH W/PILOT

KEYED SWITCH

4-WAY SWITCH

3-WAY SWITCH

SINGLE POLE SWITCH

BUS DUCT W/ PLUG IN DISCONNECT

PS - D2

T1

PANELBOARD IDENTIFICATION

KEYED NOTE (SEE SCHEDULE)

NUMBER OF SHEET WHERE DETAIL APPEARS

NUMBER OF DETAIL ON SHEET

REVISION NUMBER - SHOWN ON PLANS

ROOM NAME AND NUMBER

ITEM TO BE

REMOVED

AREA NOT IN

CONTRACT

IDENTITY (SEE SCHEDULE)

EXISTING TO REMAIN RELOCATED DEMOLISHED

d ee

2,4

T1

FLOOR CLEARANCE AREA

CONDUIT IN CEILING, FLOOR OR WALL AS REQUIRED BY FIELD

CONDITIONS

CONDUIT IN FLOOR

P4N12

1. EQUIPMENT DESIGNATION:

L = LIGHTING

P = POWER

D = DISTRIBUTION

S = SWITCHBOARD

M = MOTOR CONTROL CENTER

R = RELAY PANEL

2. VOLTAGE DESIGNATION:

1 = 120/240V - 1PH

2 = 240V - 3PH

3 = 208Y/120V - 3PH

4 = 480Y/277V - 3PH

5 = 120/208 - 1PH

6 = SPECIAL

3. SYSTEM DESIGNATION:

N = NORMAL

E = EMERGENCY

C = POWER CONDITIONED

U = UNINTERRUPTIBLE POWER SOURCE

4. FLOOR DESIGNATION:

B = BASEMENT

G = GROUND

1 = FIRST FLOOR

2 = SECOND FLOOR

ETC.

5. PANEL NO. DESIGNATION:

1 = PANELBOARD #1

2 = PANELBOARD #2

3 = PANELBOARD #3

ETC.

FIRE ALARM PULL STATION

FIRE ALARM DOOR HOLDER

FIRE ALARM DOOR CLOSER

FIRE ALARM SHUT DOWN RELAY

CEILING DATA OUTLET

FLOOR DATA OUTLET

# OF VOICE AND # OF DATA PORTS

EXAMPLE 1V2D = 1 VOICE, 2 DATA

P4N-102

1, 3, 5

#10

#12

EXISTING TO REMAIN

EXISTING TO BE REMOVED

NEW

GRAPHICAL REPRESENTATION OF PHASING, TYPICAL FOR ALL

SYMBOLS.

CEILING DUPLEX RECEPT.

SPECIAL RECEPTACLE

CEILING JUNCTION BOX

FLOOR TELEPHONE OUTLET

(MOUNTING HEIGHT)

CLNG

ELEC-1

Room

FIRE ALARM SPEAKER W/STROBE

EXIT LIGHT, WALL-MOUNTED,

SHADING AND ARROWS INDICATE

FACES AND DIRECTION

WALL-MOUNTED FIXTURES, TYPICAL

EXW1

LIGHTING FIXTURE TAG DESCRIPTORS:

TOP VALUE: FIXTURE TYPE ID.

BOTTOM VALUE, NUMBER: CIRCUIT NUMBER, REFER TO

DRAWINGS FOR PANEL.

BOTTOM VALUE, LOWERCASE LETTER: SWITCH DESIGNATION.

ABSENCE OF A SWITCH ID INDICATES FIXTURE IS CONTROLLED BY THE

ONLY SWITCH IN THE SPACE.

"x" IN PLACE OF THE SWITCH ID INDICATES NIGHT LIGHT, UNSWITCHED.

S3

1d

ELECTRIC STRIKE

MAGNETIC LOCK

COMBINATION LOCK

DOOR CONTACT

CARD READER

SECURITY KEYPAD

MOTION DETECTOR

NURSE CALL EMERG. STATION

NURSE CALL CODE BLUE STATION

NURSE CALL DUTY STATION

NURSE CALL STAFF STATION

NURSE CALL PATIENT STATION

NURSE CALL DOME LIGHT

(1-COLOR)

TELEPHONE OUTLET

VOICE/DATA OUTLET

DOOR BELL

DOOR BUZZER

DOOR CHIME

DOOR SIGNAL

VOLUME CONTROL

MICROPHONE OUTLET

1V 2D

CATV OUTLET

TV OUTLET

NURSE CALL DOME LIGHT

(4-COLORS)

NURSE CALL DOME LIGHT

(2-COLORS)

AUTO DOOR PUSH PAD

EMERGENCY LIGHTING UNIT, WALL-

MOUNTED, REMOTE BATTERY

EMERGENCY LIGHTING UNIT, WALL-

MOUNTED, INTEGRAL BATTERY

EMERGENCY LIGHTING UNIT, CEILING-

MOUNTED, INTEGRAL BATTERY

EMERGENCY LIGHTING UNIT, CEILING-

MOUNTED, REMOTE BATTERY

LIGHTING FIXTURES, TYPICAL,

RECTANGULAR FILLED CIRCLES

INDICATE RECESSED, OPEN CIRCLES

INDICATE SURFACE

DIAGONAL LINE INDICATES LENSED

OUTER DOTS INDICATE SUSPENDED

LIGHTING FIXTURES, TYPICAL, ROUND

CENTER DOT INDICATES PENDANT

DIAGONAL LINE INDICATES LENSED

CHEVRON INDICATES WALL WASH

STRIP FIXTURE

DIRECTIONAL LIGHT, TRACK, FLOOD

EXIT LIGHT, CEILING-MOUNTED,

SHADING AND ARROWS INDICATE

FACES AND DIRECTION

LINEAR LIGHT, TAPE LIGHT

EXIT/ELU COMBO

DIAGONAL HATCH INDICATES LIGHT

ON A CRITICAL CIRCUIT

SOLID HATCH INDICATES LIGHT ON

AN EMERGENCY OR LIFE SAFETY

CIRCUIT

POLE/AREA LIGHTS

POST-TOP AREA LIGHT

BOLLARD LIGHT

SPRINKLER FLOW SWITCH

SPRINKLER VALVE TAMPER SWITCH

DUCT SMOKE DETECTOR

THERMAL DETECTOR

ELECTRICAL SYMBOL LEGEND

# OF COLORS.

NEMA CONFIGURATION

DUPLEX RECEPTACLE ON

EMERGENCY CIRCUIT

DUPLEX ISOLATED GROUND RECEPT.

SPLIT DUPLEX RECEPTACLE

DUPLEX RECEPTACLE

GFI DUPLEX RECEPT. (FEED

THROUGH)

GFI WEATHERPROOF RECEPT.

DUPLEX RECEPT.

TAMPER-PROOF DUPLEX

RECEPTACLE

DUPLEX RECEPTACLE

WATER COOLER RECEPTACLE

COORDINATE THE LOCATION WITH

THE EQUIPMENT SUPPLIER

GA GAUGE

GAL GALLON

GALV GALVANIZED

GC GENERAL CONTRACTOR

GEN GENERATOR

GFI GROUND FAULT CIRCUIT

INTERRUPTER

GFP GROUND FAULT PROTECTOR

GND GROUND

GRS GALVANIZED RIGID STEEL

(CONDUIT)

GYP BD GYPSUM BOARD

HOA HANDS-OFF-AUTOMATIC SWITCH

HORIZ HORIZONTAL

HP HORSEPOWER

HPF HIGH POWER FACTOR

HT HEIGHT

HTG HEATING

HTR HEATER

HV HIGH VOLTAGE

HVAC HEATING, VENTILATING AND AIR

CONDITIONING

G ISOLATED GROUND

IMC INTERMEDIATE METAL CONDUIT

INCAND INCANDESCENT

IR INFRARED

I/W INTERLOCK WITH

J-BOX JUNCTION BOX

KV KILOVOLT

KVA KILOVOLT-AMPERE

KVAR KILOVOLT-AMPERE REACTIVE

KW KILOWATT

KWH KILOWATT HOUR

LOC LOCATE OR LOCATION

LT LIGHT

LTG LIGHTING

LTNG LIGHTNING

LV LOW VOLTAGE

MAX MAXIMUM

MAG.S MAGNETIC STARTER

M/C MOMENTARY CONTACT

MC MECHANICAL CONTRACTOR

MCB MAIN CIRCUIT BREAKER

MCC MOTOR CONTROL CENTER

MDC MAIN DISTRIBUTION CENTER

MDP MAIN DISTRIBUTION PANEL

MFR MANUFACTURER

MFS MAIN FUSED DISCONNECT

SW

MH MANHOLE

MIC MICROPHONE

MIN MINIMUM

MISC MISCELLANEOUS

MLO MAIN LUGS ONLY

MMS MANUAL MOTOR STARTER

MOA MULTIOUTLET ASSEMBLY

MSP MOTOR STARTER

PANELBOARD

MSBD MAIN SWITCHBOARD

MT MOUNT

MT.C EMPTY CONDUIT

MTS MANUAL TRANSFER SWITCH

MTR MOTOR, MOTORIZED

N.C. NORMALLY CLOSED

NEC NATIONAL ELECTRICAL CODE

NEMA NATIONAL ELECTRICAL

MANUFACTURER'S

ASSOCIATION

NFDS NON-FUSED SAFETY

DISCONNECT SWITCH

NIC NOT IN CONTRACT

NL NIGHT LIGHT

N.O. NORMALLY OPEN

NPF NORMAL POWER FACTOR

NTS NOT TO SCALE

OH OVERHEAD

OL OVERLOADS

PA PUBLIC ADDRESS

PB PULL BOX OR PUSHBUTTON

PE PNEUMATIC ELECTRIC

PED PEDESTAL

PF POWER FACTOR

PH PHASE

PIV POST INDICATING VALVE

PNL PANEL

PP POWER POLE

PR PAIR

ELECTRICAL ABBREVIATIONS LIST

PRI PRIMARY

PROJ PROJECTION

PRV POWER ROOF VENTILATOR

PT POTENTIAL TRANSFORMER

PVC POLYVINYL CHLORIDE

(CONDUIT)

PWR POWER

QUAN QUANTITY

RCPT RECEPTACLE

REQD REQUIRED

RM ROOM

RSC RIGID STEEL CONDUIT

RTU ROOF TOP UNIT

SC SURFACE CONDUIT

SEC SECONDARY

SHT SHEET

SIM SIMILAR

S/N SOLID NEUTRAL

SPEC SPECIFICATION

SPKR SPEAKER

SP SPARE

SR SURFACE RACEWAY

SS STAINLESS STEEL

SSW SELECTOR SWITCH

S/S STOP/START PUSHBUTTONS

STA STATION

STD STANDARD

SURF SURFACE MOUNTED

SW SWITCH

SWBD SWITCHBOARD

SYM SYMMETRICAL

SYS SYSTEM

TEL TELEPHONE

TEL/DAT TELEPHONE/DATA

TERM TERMINAL

TL TWIST LOCK

TR TAMPER RESISTANT

T-STAT THERMOSTAT

TTC TELEPHONE TERMINAL

CABINET

TV TELEVISION

TVTC TELEVISION TERMINAL

CABINET

TYP TYPICAL

UC UNDER COUNTER

UE UNDERGROUND ELECTRICAL

UG UNDERGROUND

UH UNIT HEATER

UT UNDERGROUND TELEPHONE

UTIL UTILITY

UV ULTRAVIOLET

V VOLT

VA VOLT-AMPERES

VDT VIDEO DISPLAY TERMINAL

VERT VERTICAL

VFD VARIABLE FREQUENCY DRIVE

VOL VOLUME

W WATT

W/ WITH

WG WIRE GUARD

WH WATER HEATER

W/O WITHOUT

WP WEATHERPROOF

XFMR TRANSFORMER

XFR TRANSFER

∠ ANGLE

@ AT

▲ DELTA

' FEET

" INCHES

# NUMBER

Ø PHASE

C CENTER LINE

P PLATE

* NOTE *

ALL GENERAL NOTES ON THIS SHEET ARE TO BE APPLIED TO ALL OTHER

DRAWINGS IN THIS SET. THE SYMBOLS AND ABBREVIATIONS SHOWN ON THIS

SHEET MAY OR MAY NOT BE USED IN THIS SET OF DRAWINGS.

1P 1 POLE (2P, 3P, 4P, ETC.)

A AMPERE

AC ABOVE COUNTER

ACLG ABOVE CEILING

ADO AUTOMATIC DOOR OPENER

AF AMP FRAME

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AFI ARC FAULT CIRCUIT

INTERRUPTER

AHU AIR HANDLING UNIT

AL ALUMINUM

ALT ALTERNATE

AMP AMPERE

AMPL AMPLIFIER

ANNUN ANNUNCIATOR

APPROX APPROXIMATELY

AQ-STAT AQUASTAT

ARCH ARCHITECT, ARCHITECTURAL

AS AMP SWITCH

AT AMP TRIP

ATS AUTOMATIC TRANSFER SWITCH

AUTO AUTOMATIC

AUX AUXILIARY

AV AUDIO VISUAL

AWG AMERICAN WIRE GAUGE

BATT BATTERY

BD BOARD

BLDG BUILDING

BMS BUILDING MANAGEMENT SYSTEM

C CONDUIT

CAB CABINET

CAT CATALOG

CATV CABLE TELEVISION

CB CIRCUIT BREAKER

CCTV CLOSED CIRCUIT TELEVISION

CKT CIRCUIT

CLG CEILING

COMB COMBINATION

CMPR COMPRESSOR

CONN CONNECTION

CONST CONSTRUCTION

CONT CONTINUATION OR

CONTINUOUS

CONTR CONTRACTOR

CONV CONVECTOR

CP CIRCULATING PUMP

CRT CATHODE-RAY TUBE

CT CURRENT TRANSFORMER

CTR CENTER

CU COPPER

DCP DOMESTIC WATER CIRCULATING

PUMP

DEPT DEPARTMENT

DET DETAIL

DIA DIAMETER

DISC DISCONNECT

DIST DISTRIBUTION

DN DOWN

DPR DAMPER

DS SAFETY DISCONNECT SWITCH

DT DOUBLE THROW

DWG DRAWING

EC ELECTRICAL CONTRACTOR

ELEC ELECTRIC, ELECTRICAL

ELEV ELEVATOR

ELU EMERGENCY LIGHTING UNIT

EM EMERGENCY

EMS ENERGY MANAGEMENT SYSTEM

EMT ELECTRICAL METALLIC TUBING

EP ELECTRIC PNEUMATIC

EQUIP EQUIPMENT

EWC ELECTRIC WATER COOLER

EXIST EXISTING

EXH EXHAUST

EXP EXPLOSION PROOF

FA FIRE ALARM

FABP FIRE ALARM BOOSTER POWER

SUPPLY PANEL

FACP FIRE ALARM CONTROL PANEL

FCU FAN COIL UNIT

FIXT FIXTURE

FLR FLOOR

FLUOR FLUORESCENT

FU FUSE

FUDS FUSED SAFETY DISCONNECT

SWITCH

1d

CEILING SMOKE DETECTOR

XX-1

XX-1

XX-1 XX-1

MOTOR

H

H

I

I

6 6

7 7 8a 8a

9 9

Jb

Jb

8 8

VASC. LAB

A347

GENERAL PROJECT NOTES

1 ELECTRICAL WORK SHALL BE PERFORMED UNDER THE SUPERVISION OF A

LICENSED MASTER ELECTRICIAN. PROCURE PERMITS AND LICENSES AND PAY FEES

ASSOCIATED WITH THIS WORK.

2 PERFORM WORK TO COMPLY WITH THE STANDARD PRACTICES FOR GOOD

WORKMANSHIP PUBLISHED BY NATIONAL ELECTRICAL CONTRACTORS

ASSOCIATION (NECA). COMPLY WITH THE LATEST ENFORCED EDITION OF THE

NATIONAL ELECTRICAL CODE (NEC), LOCAL CODES, AMENDMENTS, AND

ORDINANCES.

3 MATERIALS FURNISHED FOR THIS PROJECT SHALL BE NEW, COMMERCIAL GRADE,

FREE OF DEFECTS, AND LISTED BY A NATIONALLY RECOGNIZED TESTING

LABORATORY UNO.

4 LEAVE THE SITE CLEAN AND READY FOR OCCUPANCY. REMOVE DIRT, DEBRIS,

EMPTY CARTONS, TOOLS, CONDUIT AND WIRE SCRAPS AND MISCELLANEOUS

SPARE EQUIPMENT AND MATERIALS USED IN THIS DIVISION OF THE WORK DURING

CONSTRUCTION. COMPONENTS SHALL BE FREE OF DUST, GRIT AND FOREIGN

MATERIALS AND LEFT AS NEW BEFORE FINAL ACCEPTANCE OF WORK.

5 THE SYMBOLS AND ABBREVIATIONS SHOWN ON THIS SHEET MAY OR MAY NOT BE

USED IN THIS SET OF DRAWINGS.

6 CONTRACTOR SHALL BE RESPONSIBLE FOR WIRING ELECTRICAL ITEMS SHOWN

ON DRAWINGS.

7 PROVIDE CABLE OR CONDUIT AND WIRE AS REQUIRED TO ACHIEVE CIRCUITING

SHOWN. SIZE CONDUCTORS PER NEC AMPACITY AND WIRE FILL CRITERIA.

PROVIDE DEDICATED NEUTRAL AND GROUND CONDUCTORS FOR CIRCUITING,

UNLESS NOTED OTHERWISE. INCREASE BRANCH CIRCUIT AND/OR FEEDER

CONDUCTORS INCLUDING EQUIPMENT GROUNDING CONDUCTORS

PROPORTIONALLY FOR NO MORE THAN 3% VOLTAGE DROP ON BRANCH

CIRCUITS AND 2% ON FEEDERS PER ENERGY CODE.

8 COORDINATE LOCATIONS OF DEVICES WITH ARCHITECTURAL ELEVATIONS AND

DETAILS. ARCHITECTURAL ELEVATIONS AND DETAILS TAKE PRECEDENCE OVER

LOCATIONS SHOWN ON ELECTRICAL DRAWINGS.

9 COORDINATE WITH OTHER TRADES FOR PROPER INSTALLATION OF ELECTRICAL

COMPONENTS. CONSULT THE DRAWINGS OF OTHER TRADES OR CRAFTS TO

AVOID CONFLICTS WITH EQUIPMENT, ETC. CONFLICTS SHALL BE RESOLVED PRIOR

TO ROUGH-IN AND AT NO ADDITIONAL COST TO THE OWNER.

10 COORDINATE INSTALLATION OF ELECTRICAL SYSTEMS AND THOSE REQUIRING

ELECTRICAL CONNECTIONS TO MAINTAIN NEC REQUIRED CLEARANCES,

INCLUDED BY NOT LIMITED TO AREAS ABOVE ACCESSIBLE CEILINGS.

VA Project No.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

STAMP

CONSULTANT

321 4 5 6 7 8 9 10

REPLACE DAMAGED

FLOORING

5/11/2023

ELECTRICAL GENERAL INFO &

SYMBOL LEGEND, AND THIRD

FLOOR DEMOLITION PLAN

E001

SMBC

539-23-202

CINCINNATI MEDICAL CENTER

VA Station No:

BID DOCUMENTS

GENERAL ELECTRICAL REMODEL NOTES

1 BRANCH CIRCUITING INDICATED ON PLANS AND SCHEDULES IS BASED UPON

EXISTING PLANS AND SITE OBSERVATION, CONTRACTOR SHALL FIELD VERIFY THE

EXISTING CONDITIONS.

2 PROVIDE TYPED CIRCUIT BOARD DIRECTORIES TO REFLECT AS-CONSTRUCTED

CONDITIONS. FIELD VERIFY DURING CONSTRUCTION AND REVISE

ACCORDINGLY.

3 PROVIDE NECESSARY DEMOLITION TO FACILITATE NEW CONSTRUCTION WORK

ASSOCIATED WITH THIS PROJECT. COORDINATE OUTAGES WITH OWNER

MINIMUM 72 HOURS IN ADVANCE. THE OWNER RETAINS THE FIRST RIGHT OF

REFUSAL FOR SALVAGE OF DEMOLISHED MATERIALS. PROVIDE DISPOSAL OF

REMOVED MATERIAL. MAINTAIN CIRCUIT CONTINUITY AS REQUIRED.

4 IT IS THE INTENT OF THESE DIAGRAMMATIC DRAWINGS TO PROVIDE THE PROJECT

SCOPE INCLUDING, BUT NOT LIMITED TO PHASED DEMOLITION AND NEW

CONSTRUCTION. EXISTING INFORMATION INDICATED ON THESE PLANS DOES NOT

REPRESENT ALL EXISTING CONDITIONS. THIS CONTRACTOR SHALL BECOME

FAMILIAR WITH EXISTING CONDITIONS, SCOPE OF PHASING, AND PROJECT

INTENT PRIOR TO BID SUBMISSION. NO EXTRA WILL BE ALLOWED DUE TO THE LACK

OF KNOWLEDGE OF EXISTING CONDITIONS TO…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .