Attachment 1 - Replace Damaged Flooring - Drawings.pdf
PDF 8 MB Posted
- Attached to
- Z1DA--Replace Damaged Flooring 539-23-202
- Solicitation number
- 36C25024B0019
About this file
This solicitation is for a construction project to replace damaged flooring throughout a Department of Veterans Affairs hospital. The project scope includes removing all carpet left in the hospital as well as isolated toilets that may be the source of water damage. General construction, electrical, and technology work is required. The period of performance is 90 days from notice to proceed.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25024B0019 0002.docx | DOCX document | |
| 36C25024B0019 0001.docx | DOCX document | |
| 36C25024B0019_1.docx | DOCX document | |
| Attachment 2 - Replace Damaged Flooring - Project Manual Specs.pdf | ||
| 36C25024B0019_1.pdf | ||
| Attachment 7 - EMR.docx | DOCX document | |
| WD.txt | TXT text file | |
| Attachment 3 - VAAR 852.219-75 VA Notice of Limitations on Subcontracting (JAN 2023).pdf | ||
| Attachment 4 - VHA_Directive_1192.pdf | ||
| Attachment 5 - RFI Form-36C25023B0034.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
STAMP
CONSULTANTS:
321 4 5 6 7 8 9 10
5/8/2023 1:05:38 PM
REPLACE DAMAGED
FLOORING
05/11/2023
COVER SHEET
GI001
AHSS
539-23-202
CINCINNATI MEDICAL CENTER
VA Station No:
BID DOCUMENTS
CINCINNATI, OHIO
NORTH
PROJECT TEAM DRAWING SHEET INDEX
ENVIRONMENTAL ENGINEERING:
ARCHITECTURE:
OWNER: DESCRIPTIONSHEET ISSUE DATE
PHONE: 269.927.0144
SEVEN GENERATIONS AE
KALAMAZOO, MICHIGAN 49007
600 E. MICHIGAN AVE, SUITE B
ARC ENVIRONMENTAL
BALTIMORE, MARYLAND 21230
1311 HAUBERT ST.
VA CINCINNATI HEALTH CARE SYSTEM
CINCINNATI, OHIO 45220
3200 VINE STREET
REPLACE DAMAGED FLOORING
CINCINNATI, OHIO
DEPARTMENT OF VETERANS AFFAIRS
GI001 COVER SHEET 05/11/2023
GI002 GENERAL INFORMATION & SYMBOLS 05/11/2023
GC100 COMPOSITE AND PHASING PLAN - BASEMENT 05/11/2023
GC101 COMPOSITE AND PHASING PLAN - FIRST FLOOR 05/11/2023
GC102 COMPOSITE AND PHASING PLAN - SECOND FLOOR 05/11/2023
GC103 COMPOSITE AND PHASING PLAN - THIRD FLOOR 05/11/2023
GC104 COMPOSITE AND PHASING PLAN - FOURTH FLOOR 05/11/2023
GC107 COMPOSITE AND PHASING PLAN - SEVENTH FLOOR 05/11/2023
ID100 INTERIOR DEMOLITION PLANS 05/11/2023
IN100 FINISH KEY & DETAILS 05/11/2023
IN101 FINISH PLANS 05/11/2023
P001 PLUMBING GENERAL INFO & SYMBOL LEGEND, AND THIRD FLOOR DEMOLITION
PLAN
3/31/2023
E001 ELECTRICAL GENERAL INFO & SYMBOL LEGEND, AND THIRD FLOOR DEMOLITION
PLAN
3/31/2023
PROJECT LOCATION
PROJECT LOCATION
SCOPE PRIORITY ROOM SCHEDULE
ROOM
NUMBER ROOM NAME Area
ICRA
CLASS
PRIORITY 1
A251 STUDENT OFF. 70 SF CLASS II
A256 VIEWING 114 SF CLASS II
A257 READING ROOM 177 SF CLASS II
A258 READING ROOM 135 SF CLASS II
A259 ADM. 130 SF CLASS II
A260 CHIEF RADIOLOGY 188 SF CLASS II
A261 ADM. ASST. 199 SF CLASS II
A262 OFF. 141 SF CLASS II
A262A READING ROOM 105 SF CLASS II
A263 RESIDENT READING
ROOM
116 SF CLASS II
A264 READING ROOM 117 SF CLASS II
A300 VASC. LAB 148 SF CLASS II
A347 VASC. LAB 138 SF CLASS III
A347A TLT. 18 SF CLASS III
A379 VASC. LAB 277 SF CLASS II
B135 OFF. 116 SF CLASS II
C002 MEDICAL RECORDS
STORAGE
1,020 SF CLASS II
PRIORITY 1: 17 3,209 SF
PRIORITY 2
A144 DECEDENT AFFAIRS 186 SF CLASS II
A144A CONF. ROOM 198 SF CLASS II
A301 OFFICE 256 SF CLASS II
A302 CHIEF DIET. 145 SF CLASS II
A303 DIET SEC. 146 SF CLASS II
A321 CHIEF OFF. 149 SF CLASS II
A353 OFF. 162 SF CLASS II
A422A SOCIAL WORKER 130 SF CLASS II
A755 OFFICE #8 157 SF CLASS II
A770 TESTING 76 SF CLASS II
A775 OFFICE #18 146 SF CLASS II
B326 FAMILY WAITING 607 SF CLASS III
B327 RECEPTION 151 SF CLASS II
B711 OFF. 114 SF CLASS II
C037 AUD. BOOTH 102 SF CLASS II
C037A AUD. BOOTH 105 SF CLASS II
C314 ICU DIR. OFF. 151 SF CLASS II
C360 EMS 77 SF CLASS II
C3002 WAITING 427 SF CLASS III
C3005 CONSULT. 124 SF CLASS III
PRIORITY 2: 20 3,609 SF
Grand total: 37 6,818 SF
ENGINEERING:
PHONE: 269.585.2255
ALLIANCE | STEELHEAD JV
KALAMAZOO, MICHIGAN 49007
259 E. MICHIGAN AVE, SUITE 407
Revisions Date
Stephanie Sokolowski Snapshot
A300
A320
ARCHITECTURAL SYMBOLS & PLAN INDICATORS
ABBREVIATIONSBARRIER-FREE DESIGN INFORMATION
ROOMNAME
XXX
A
A
A
A
8'-0"
TOP OF STEEL
ELEV. 10'-0"
A200
TITLE
SCALE X" = 1'-0"
TYP. BARRIER FREE TOILET ROOM FIXTURES
SCALE: NONE
TYP. BARRIER FREE TOILET ROOM FIXTURES
SCALE: NONE
OBSTRUCTED APPROACH UNOBSTRUCTED APPROACH
TYP. CODE REGULATED MOUNTING HEIGHTS
SCALE: NONE
TYP. EQUIPMENT MOUNTING HEIGHTS
SCALE: NONE
ELEVATION INDICATION
SHEET NO.
ELEVATION NUMBER
SECTION INDICATOR
ENLARGED PLAN OR
ELEVATION
PROPOSED SPOT
EXISTING SPOT
ELEVATION
100.57'
100.57'
STRUCTURAL SPAN
ROOF TRUSSES
FLOOR JOIST OR
RAMP
@ 16" O.C.
2 x 12
1" per 12"
SLOPE UP
REVISION TAG W/
REVISION NUMBER
KEYNOTE TAG
WINDOW TAG W/
WINDOW TYPE
INDICATOR
WALL SECTION CUT
COLUMN LINE
WALL TYPES
ELEVATION
BUILDING SECTION CUT
SHEET LOCATION
DETAIL NUMBER
TYPICAL
DIMENSIONING
SET-BACK LINE
PROPERTY LINE
EXISTING
CONTOUR
TOPOGRAPHY
CONTOUR
100'
100'
TOPOGRAPHY
PROPOSED
SECTIONS & DETAILS
TYPICAL TITLE FOR
DOOR NUMBER
DOOR TAG W/
ROOM NUMBER
ROOM NAME/
NORTH ARROW
60" DIAMETER CLEAR
WHEELCHAIR TURNING
SPACE - REFER TO PLAN
- REFER TO PLAN
AND GROUND SPACE
30" x 48" CLEAR FLOOR
CEILING HEIGHT TAG
MIRRORGRAB
BARS
TOILET PAPER
GRAB BARS
5'-0" DIA.
CLEAR FLOOR
SPACE
60" WIDE BY 59" DEEP
CLEAR FLOOR AREA AT
WATER CLOSET
2'-6" x 4'-0"
CLEAR FLOOR
AREA AT SINK
* DIMENSION IS TO BOTTOM
OF REFLECTIVE SURFACE
RECEPTACLE
LIGHT
SWITCH
HVAC
CONTROLS
FIRE
ALARM
FEC
LESS THAN 40#
FEC
GREATER THAN 40#
TEL
PUSH PAD
RH/CH
GBX
SH1
CL
OT
SPH
CRK SND
PT
SD
HS
XR COM4 MR
CRBG
WP
TP SNR
4'-4"
TV
MOUNTING HEIGHT GENERAL NOTES:
1. ITEMS ON THIS SHEET ARE NOT NECESSARILY
INCLUDED IN THIS PROJECT.
2. CONTRACTOR TO VERIFY ALL EQUIPMENT
MOUNTING HEIGHTS WITH OWNER/AE
PRIOR TO INSTALLATION.
3. REFER TO MECHANICAL/ELECTRICAL
DRAWINGS FOR DEVICE MOUNTING
HEIGHTS.
XXXNORTH
M A
X
M
IN
/1
" 4
" 5
M A
X
6" 3' - 0"
1' - 6" 3' - 6"
MIN
1' - 3"
5' - 0"
M
IN
6" 3' - 0"
M A
X
3' - 6" 1' - 0"
M
IN
M
A X
M
IN
M
IN
M A
X
SIDE FRONT
M
A X
M
A X
20" - 25"
M
A X
FRONT
M
A X
20" MAX
SIDE
SIDE FRONT
M
IN
M
A X
M
IN
M
A X
@ AT
A/C AIR CONDITIONING/AIR CONDITIONER
ACOUS ACOUSTICAL
AD AREA DRAIN, AUTOMATIC DAMPER
ADJ ADJUST, ADJUSTABLE
ALUM ALUMINUM
AP ACCESS PANEL
ACT ACOUSTICAL CEILING
B BASE
BAR BARRIER
BD BOARD
BF BARRIER FREE
BKT BRACKET
BLDG BUILDING
BLKG BLOCKING
BOTT BOTTOM
C TO C CENTER TO CENTER
CAB CABINET
CE COLUMN ENCLOSURE
CIR CIRCLE
CIR CIRCUIT
CL CENTER LINE, CLEARANCES
CLG CEILING
CJ CONTROL JOINT
CLKG CAULKING
CLO CLOSET
CMT CERAMIC MOSAIC TILE
CMU CONCRETE MASONRY UNIT
CO CLEANOUT
COL COLUMN
CONC CONCRETE
CONT CONTINUOUS
CORR CORRIDOR
CPT CARPET
CSS CLINICAL SERVICE SINK
CT CERAMIC TILE
CTR CENTER
CUH CABINET UNIT HEATER
DEMO DEMOLITION, DEMOLISH
DEPT DEPARTMENT
DF DRINKING FOUNTAIN
DIA, D DIAMETER
DIM DIMENSION
DN DOWN
DR DRAIN
DS DOWNSPOUT
ELECT ELECTRICAL
ELEV ELEVATION
ENTR ENTRANCE
EQ EQUAL
EP ELECTRICAL PANEL
EXH EXHAUST
EXP EXPOSED
EXIST EXISTING, EXSIST'G
EXT EXTERIOR
EW EACH WAY
FA FIRE ALARM
FD FIRE DAMPER OR FLOOR DRAIN
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FIN FINISH
FL, FLR FLOOR FINISH
FLG, FLRG FLOORING, FLOOR'G
FURN FURNITURE, FURNACE
FWC FABRIC WALL COVERING
FT FEET, FOOT
GALV GALVANIZE(D)
GL GLASS
GSB GYPSUM SHEATHING BOARD
GWB GYPSUM WALLBOARD
GYP. BD GYPSUM BOARD
ID INSIDE DIAMETER
INSUL INSULATION
IN INCH(ES)
JAN JANITOR'S CLOSET
HM HOLLOW METAL
HORIZ HORIZONTAL
HR HANDRAIL
HT HEIGHT
HW HEADWALL
LAM LAMINATED
LF LINEAL FEET
MAS MASONRY
MAT'L MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MANUF MANUFACTURED, MANUFACTURER
MIN MINIMUM
MLD'G MOLDING
MTL METAL
N NORTH
NAT NATURAL
NIC NOT IN CONTRACT
NORM NORMAL
NTS NOT TO SCALE
O.C. ON CENTER
OPN'G OPENING
O, O2 OXYGEN
PLAST PLASTIC
PNT PAINT
PREFAB PREFABRICATED
PLYWD PLYWOOD, PLYW'D
R RADIUS
RA RETURN AIR
REQ'D REQUIRED
RM ROOM
S SINK, SOUTH, SHINGLE
SA SUPPLY AIR
SAN SANITARY
SMKD SMOKE DAMPER
SECT SECTION
SHWR SHOWER
SIM SIMILAR
SPEC SPECIFICATION
SQ SQUARE
SS SERVICE SINK, STAINLESS STEEL
STD STANDARD
STOR STORAGE
SUSP SUSPEND(ED)
SYM SYMBOL, SYMMETRICAL
TOIL TOILET
TYP TYPICAL
UNFIN UNFINISHED
UTIL UTILITY
VAC VACUUM
VAV VARIABLE AIR VOLUME
VCT VINYL COMPOSITION TILE
VD VOLUME DAMPER
VERT VERTICAL
V.I.F. VERIFY IN FIELD
VT VINYL TILE
VWC VINYL WALL COVERING
W/ WITH
WC WATER CLOSET
WD WOOD
WNDW WINDOW
W. HTR WATER HEATER
W/O WITHOUT
WP WALL PROTECTION
A420
A320
M
A X
M
IN
18" MAX.
16" MIN.
IF
B A
R R
IE
R
F R
E E
M
A X
M
IN
M
IN
VA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
STAMP
CONSULTANTS:
321 4 5 6 7 8 9 10
5/8/2023 1:05:38 PM
REPLACE DAMAGED
FLOORING
05/11/2023
GENERAL INFORMATION &
SYMBOLS
GI002
AHSS
539-23-202
CINCINNATI MEDICAL CENTER
VA Station No:
BID DOCUMENTS
Revisions Date
5/8/2023 1:05:38 PM
DN
1020 SF
C002
MEDICAL RECORDS
STORAGE
102 SF
C037
AUD. BOOTH
105 SF
C037A
AUD. BOOTH
ID100
IN101
IN101
ID100
PHASING LEGEND
AREAS INCLUDED IN CONTRACT SCOPE OF WORK
INDICATES AREA REQUIRING AFTER-HOURS LABOR.
AREA SHALL REMAIN OPEN TO REGULAR
OPERATIONS DURING NORMAL BUSINESS HOURS.
ALL DEMO & NEW WORK SHALL TAKE PLACE
DURING THE WINDOW OF 6:00 PM - 5:00 AM
MONDAY THROUGH FRIDAY AND ALL DAY
SATURDAYS & SUNDAYS.
VA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
STAMP
CONSULTANTS:
321 4 5 6 7 8 9 10
5/8/2023 1:05:42 PM
REPLACE DAMAGED
FLOORING
05/11/2023
COMPOSITE AND PHASING PLAN -
BASEMENT
GC100
AHSS
539-23-202
CINCINNATI MEDICAL CENTER
VA Station No:
BID DOCUMENTS
N Scale: 1/16" = 1'-0"
BASEMENT PLAN
198 SF
A144A
CONF. ROOM
116 SF
B135
OFF.
ID100
IN101
ID100
IN101
186 SF
A144
DECEDENT AFFAIRS
PHASING LEGEND
AREAS INCLUDED IN CONTRACT SCOPE OF WORK
INDICATES AREA REQUIRING AFTER-HOURS LABOR.
AREA SHALL REMAIN OPEN TO REGULAR
OPERATIONS DURING NORMAL BUSINESS HOURS.
ALL DEMO & NEW WORK SHALL TAKE PLACE
DURING THE WINDOW OF 6:00 PM - 5:00 AM
MONDAY THROUGH FRIDAY AND ALL DAY
SATURDAYS & SUNDAYS.
VA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
STAMP
CONSULTANTS:
321 4 5 6 7 8 9 10
5/8/2023 1:05:49 PM
REPLACE DAMAGED
FLOORING
05/11/2023
COMPOSITE AND PHASING PLAN -
FIRST FLOOR
GC101
AHSS
539-23-202
CINCINNATI MEDICAL CENTER
VA Station No:
BID DOCUMENTS
N Scale: 1/16" = 1'-0"
FIRST FLOOR PLAN
IN101
IN101
177 SF
A257
READING ROOM
135 SF
A258
READING ROOM
130 SF
A259
ADM.
188 SF
A260
CHIEF RADIOLOGY
199 SF
A261
ADM. ASST.
141 SF
A262
OFF.
117 SF
A264
READING ROOM
105 SF
A262A
READING ROOM
70 SF
A251
STUDENT OFF.
ID100
ID100
116 SF
A263
RESIDENT READING
ROOM
114 SF
A256
VIEWING
PHASING LEGEND
AREAS INCLUDED IN CONTRACT SCOPE OF WORK
INDICATES AREA REQUIRING AFTER-HOURS LABOR.
AREA SHALL REMAIN OPEN TO REGULAR
OPERATIONS DURING NORMAL BUSINESS HOURS.
ALL DEMO & NEW WORK SHALL TAKE PLACE
DURING THE WINDOW OF 6:00 PM - 5:00 AM
MONDAY THROUGH FRIDAY AND ALL DAY
SATURDAYS & SUNDAYS.
VA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
STAMP
CONSULTANTS:
321 4 5 6 7 8 9 10
5/8/2023 1:05:57 PM
REPLACE DAMAGED
FLOORING
05/11/2023
COMPOSITE AND PHASING PLAN -
SECOND FLOOR
GC102
VGSS
539-23-202
CINCINNATI MEDICAL CENTER
VA Station No:
BID DOCUMENTS
N Scale: 1/16" = 1'-0"
SECOND FLOOR PLAN
UP
UP
UP
UP
IN101
IN101
IN101
IN101
IN101
IN101
IN101
IN101
IN101
124 SF
C3005
CONSULT.
427 SF
C3002
WAITING
148 SF
A300
VASC. LAB
256 SF
A301
OFFICE
145 SF
A302
CHIEF DIET.
146 SF
A303
DIET SEC.
162 SF
A353
OFF.
277 SF
A379
VASC. LAB
607 SF
B326
FAMILY WAITING
151 SF
B327
RECEPTION
77 SF
C360
EMS
151 SF
C314
ICU DIR. OFF.
149 SF
A321
CHIEF OFF.
ID100
ID100
ID100
ID100
ID100
ID100
ID100
ID100
ID100
19 SF
C3005A
138 SF
A347
VASC. LAB
PHASING LEGEND
AREAS INCLUDED IN CONTRACT SCOPE OF WORK
INDICATES AREA REQUIRING AFTER-HOURS LABOR.
AREA SHALL REMAIN OPEN TO REGULAR
OPERATIONS DURING NORMAL BUSINESS HOURS.
ALL DEMO & NEW WORK SHALL TAKE PLACE
DURING THE WINDOW OF 6:00 PM - 5:00 AM
MONDAY THROUGH FRIDAY AND ALL DAY
SATURDAYS & SUNDAYS.
VA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
STAMP
CONSULTANTS:
321 4 5 6 7 8 9 10
5/8/2023 1:06:10 PM
REPLACE DAMAGED
FLOORING
05/11/2023
COMPOSITE AND PHASING PLAN -
THIRD FLOOR
GC103
AHSS
539-23-202
CINCINNATI MEDICAL CENTER
VA Station No:
BID DOCUMENTS
N Scale: 1/16" = 1'-0"
THIRD FLOOR PLAN
IN101
130 SF
A422A
SOCIAL WORKER
ID100
PHASING LEGEND
AREAS INCLUDED IN CONTRACT SCOPE OF WORK
INDICATES AREA REQUIRING AFTER-HOURS LABOR.
AREA SHALL REMAIN OPEN TO REGULAR
OPERATIONS DURING NORMAL BUSINESS HOURS.
ALL DEMO & NEW WORK SHALL TAKE PLACE
DURING THE WINDOW OF 6:00 PM - 5:00 AM
MONDAY THROUGH FRIDAY AND ALL DAY
SATURDAYS & SUNDAYS.
VA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
STAMP
CONSULTANTS:
321 4 5 6 7 8 9 10
5/8/2023 1:06:18 PM
REPLACE DAMAGED
FLOORING
05/11/2023
COMPOSITE AND PHASING PLAN -
FOURTH FLOOR
GC104
AHSS
539-23-202
CINCINNATI MEDICAL CENTER
VA Station No:
BID DOCUMENTS
N Scale: 1/16" = 1'-0"
FOURTH FLOOR PLAN
IN101
IN101
IN101
IN101
146 SF
A775
OFFICE #18
157 SF
A755
OFFICE #8
76 SF
A770
TESTING
114 SF
B711
OFF.
ID100
ID100
ID100
ID100
PHASING LEGEND
AREAS INCLUDED IN CONTRACT SCOPE OF WORK
INDICATES AREA REQUIRING AFTER-HOURS LABOR.
AREA SHALL REMAIN OPEN TO REGULAR
OPERATIONS DURING NORMAL BUSINESS HOURS.
ALL DEMO & NEW WORK SHALL TAKE PLACE
DURING THE WINDOW OF 6:00 PM - 5:00 AM
MONDAY THROUGH FRIDAY AND ALL DAY
SATURDAYS & SUNDAYS.
VA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
STAMP
CONSULTANTS:
321 4 5 6 7 8 9 10
5/8/2023 1:06:23 PM
REPLACE DAMAGED
FLOORING
05/11/2023
COMPOSITE AND PHASING PLAN -
SEVENTH FLOOR
GC107
AHSS
539-23-202
CINCINNATI MEDICAL CENTER
VA Station No:
BID DOCUMENTS
N Scale: 1/16" = 1'-0"
SEVENTH FLOOR PLAN
FD
DEMOLITION KEY NOTES
REMOVE EXISTING WALL CONSTRUCTION AS
SHOWN. PATCH & REPAIR ADJACENT SURFACES TO
REMAIN AS NECESSARY TO PREPARE FOR NEW
CONSTRUCTION AND/OR NEW FINISHES.
REMOVE EXISTING DOOR(S), FRAME(S), HARDWARE,
ETC. TURN OVER TO OWNER UNLESS DIRECTED
OTHERWISE.
REMOVE EXISTING TOILET ACCESSORIES AND ALL
WALL MOUNTED EQUIPMENT. TURN OVER TO
OWNER UNLESS DIRECTED OTHERWISE. PATCH AND
REPAIR EXPOSED SURFACES TO REMAIN AS
REQUIRED TO RECEIVE NEW CONSTRUCTION AND
FINISHES.
REMOVE EXISTING WALL FINISHES, WALL BASE, AND
ALL ITEMS ATTACHED TO THE WALLS. TURN OVER TO
OWNER, UNLESS DIRECTED OTHERWISE. PATCH &
REPAIR EXPOSED SURFACES TO REMAIN AS
REQUIRED FOR NEW CONSTRUCTION AND/OR NEW
FINISHES.
REMOVE EXISTING FLOORING AND WALL BASE
INCLUDING ALL ADHESIVES, SETTING MATERIALS
DOWN TO EXISTING SUBSTRATE. GRIND CONCRETE
FLOORS AS REQUIRED TO PROVIDE A SMOOTH AND
UNIFORM SURFACE FOR NEW FINISHES.
REMOVE EXISTING MECHANICAL, PLUMBING &
ELECTRICAL ITEMS - REFER TO MECHANICAL,
PLUMBING & ELECTRICAL DEMOLITION PLANS FOR
FURTHER INFORMATION. PATCH AND REPAIR
EXPOSED SURFACES TO REMAIN AS REQUIRED TO
RECEIVE NEW CONSTRUCTION AND FINISHES.
ABATE & REMOVE ALL EXISTING FLOOR TILE AND
MASTIC. GRIND CONCRETE FLOORS AS REQUIRED
TO PROVIDE A SMOOTH & UNIFORM SURFACE FOR
NEW FINISHES. DISPOSE OF MATERIALS IN
ACCORDANCE TO SPECIFICATIONS.
ABATE & REMOVE EXISTING ASBESTOS INSULATION
ON PIPES TO BE DEMOLISHED. DISPOSE OF
MATERIALS IN ACCORDANCE TO SPECIFICATIONS.
ABATE & REMOVE EXISTING LEAD WALL PAINT.
CONTRACTOR SHALL PATCH & REPAIR SURFACES TO
REMAIN AS REQUIRED TO RECEIVE NEW FINISHES.
DISPOSE OF MATERIALS IN ACCORDANCE TO
SPECIFICATIONS
H1
H2
HAZARDOUS MATERIALS
DEMOLITION NOTES
H3
GENERAL DEMO NOTES
1. ALL DEMOLITION WORK REQUIRED IS NOT NECESSARILY LIMITED
TO WHAT IS SHOWN ON THE DEMOLITION PLANS. THE INTENT IS
TO REMOVE ALL MATERIALS AND ITEMS AS REQUIRED TO
FACILITATE INSTALLATION OF NEW FLOORING FINISHES.
2. CONTRACTORS ARE TO VERIFY FIELD CONDITIONS, IF
CONDITIONS DO NOT REFLECT WHAT IS NOTED IN THE
CONTRACT DOCUMENTS, THE CONTRACTOR IS TO NOTIFY THE
ARCHITECT.
3. THIS PLAN IS TO BE USED IN CONJUNCTION WITH THE ENTIRE SET
OF CONSTRUCTION DOCUMENTS. DO NOT REMOVE ANY ITEMS
WITHOUT VERIFYING AND COORDINATING WITH ALL GENERAL
TRADES AS TO HOW THEY RELATE TO THE OVERALL PROJECT.
4. CONTRACTOR IS RESPONSIBLE FOR PROVIDING DUMPSTERS.
LOCATION OF DUMPSTERS TO BE DETERMINED BY VA COR.
5. CONTRACTOR SHALL REMOVE AND DISPOSE OF ALL
DEMOLISHED MATERIALS. DO NOT ALLOW MATERIALS AND
DEBRIS GENERATED BY DEMOLITION ACTIVITIES TO
ACCUMULATE ON THE JOBSITE. REMOVE DAILY AND DISPOSE
OF IN A LEGAL MANNER. NO ONSITE SALE OR BURNING OR
REMOVED ITEMS IS PERMITTED.
6. THE CONTRACTOR MUST TAKE ALL NECESSARY PRECAUTIONS
TO ENSURE THE SAFETY OF THE PUBLIC AND/OR WORKMEN ON
THE SITE TO PREVENT ACCIDENTS OR INJURY TO ANY PERSON
ON, ABOUT OR ADJACENT TO THE PREMISES. THE CONTRACTOR
SHALL COMPLY WITH ALL LAWS, ORDINANCES, CODES AND
REGULATIONS PERTAINING TO SAFETY AND THE PREVENTION OF
ACCIDENTS.
7. THE CONTRACTOR MUST MAINTAIN ADEQUATE SUPPORT,
INSULATION, WATERPROOFING, EMERGENCY LIGHTING,
SECURITY, ALARMS, ETC. FOR ALL OR PART OF ITEMS WHICH
ARE TO REMAIN.
8. THE OWNER RESERVES THE RIGHTS TO ANY REMOVED
EQUIPMENT. CONTRACTOR TO COORDINATE WITH VA COR.
9. DO NOT CUT AND/OR PATCH STRUCTURAL ELEMENTS IN A
MANNER THAT COULD CHANGE THEIR LOAD-CARRYING
CAPACITY OR LOAD-DEFLECTION RATIO.
10. PATCH/REPAIR OR REPLACE ALL AREAS DAMAGED BY
DEMOLITION, REWORK AS REQUIRED, PREPARE FOR NEW
CONSTRUCTION AS REQUIRED.
11. WHERE WALLS & CEILINGS ARE TO BE REMOVED, ALL ITEMS
THAT FALL WITH THE WALLS &/OR CEILINGS ARE TO BE
REMOVED OR REROUTED. REFER TO MECHANICAL, ELECTRICAL,
AND PLUMBING PLANS FOR ADDITIONAL DEMOLITION NOT
SHOWN ON THIS SHEET.
12. IF HAZARDOUS MATERIALS ARE ENCOUNTERED DURING
DEMOLITION, CONTRACTOR SHALL CONTACT VA COR FOR
ABATEMENT.
13. REMOVE, REPLACE, PATCH, AND REPAIR MATERIALS AND
SURFACES CUT OR DAMAGED DURING DEMOLITION, BY
METHODS AND WITH MATERIALS SO AS NOT TO VOID EXISTING
WARRANTIES.
14. CLEAN AREAS AND SPACES WHERE CUTTING AND PATCHING
ARE PERFORMED.
15. INTERIOR WALLS TO BE REMOVED, SHALL BE REMOVED THE
ENTIRE HEIGHT OF THE WALL UNLESS REQUIRED OTHERWISE BY
NEW OPENINGS IN EXISTING WALLS TO REMAIN.
16. CONTRACTOR SHALL PATCH, REPAIR, AND INFILL ALL APPLIED
FIREPROOFING MATERIAL IN AREAS LEFT UNPROTECTED DUE TO
REMOVAL OF EXISTING ELEMENTS OR AREAS DAMAGED
DURING NEW WORK AND DEMOLITION. MATCH EXISTING
FIREPROOFING MATERIAL TYPE AND THICKNESS TO MAINTAIN
REQUIRED LEVEL OR PROTECTION.
1020 SF
C002
MEDICAL RECORDS
STORAGE
H1
105 SF
C037A
AUD. BOOTH
102 SF
C037
AUD. BOOTH
186 SF
A144
DECEDENT AFFAIRS
198 SF
A144A
CONF. ROOM
116 SF
B135
OFF.5
H1
70 SF
A251
STUDENT OFF.
H1
177 SF
A257
READING ROOM
135 SF
A258
READING ROOM
130 SF
A259
ADM.
188 SF
A260
CHIEF RADIOLOGY
199 SF
A261
ADM. ASST.
141 SF
A262
OFF.
117 SF
A264
READING ROOM
105 SF
A262A
READING ROOM
H1
H1
116 SF
A263
RESIDENT READING
ROOM
114 SF
A256
VIEWING
H1
149 SF
A321
CHIEF OFF.
H1
138 SF
A347
VASC. LAB
H2
H3
H1
18 SF
A347A
TLT.
162 SF
A353
OFF.
607 SF
B326
FAMILY WAITING
151 SF
B327
RECEPTION
151 SF
C314
ICU DIR. OFF.
148 SF
A300
VASC. LAB
256 SF
A301
OFFICE
145 SF
A302
CHIEF DIET.
146 SF
A303
DIET SEC.
277 SF
A379
VASC. LAB
5 5 5 5 5
H1H1
427 SF
C3002
WAITING
77 SF
C360
EMS
124 SF
C3005
CONSULT.
19 SF
C3005A
130 SF
A422A
SOCIAL WORKER
157 SF
A755
OFFICE #8
H1
76 SF
A770
TESTING
5146 SF
A775
OFFICE #18
H1
5114 SF
B711
OFF.
H1
VA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
STAMP
CONSULTANTS:
321 4 5 6 7 8 9 10
5/8/2023 1:06:25 PM
REPLACE DAMAGED
FLOORING
05/11/2023
INTERIOR DEMOLITION PLANS
ID100
AHSS
539-23-202
CINCINNATI MEDICAL CENTER
VA Station No:
BID DOCUMENTS
SCALE: 1/8" = 1'-0"ID100
DEMOLITION PLAN - C00201
SCALE: 1/8" = 1'-0"ID100
DEMOLITION PLAN - C037/C037A02
SCALE: 1/8" = 1'-0"ID100
DEMOLITION PLAN - A144/A144A03
SCALE: 1/8" = 1'-0"ID100
DEMOLITION PLAN - B13504
SCALE: 1/8" = 1'-0"ID100
DEMOLITION PLAN - A25105
SCALE: 1/8" = 1'-0"ID100
DEMOLITION PLAN - A257-A26412
SCALE: 1/8" = 1'-0"ID100
DEMOLITION PLAN - A32106
SCALE: 1/8" = 1'-0"ID100
DEMOLITION PLAN - A347/A347A07
SCALE: 1/8" = 1'-0"ID100
DEMOLITION PLAN - A35308
SCALE: 1/8" = 1'-0"ID100
DEMOLITION PLAN - B326/B32711
SCALE: 1/8" = 1'-0"ID100
DEMOLITION PLAN - C31409
SCALE: 1/8" = 1'-0"ID100
DEMOLITION PLAN - A300-A37913
Revisions Date
SCALE: 1/8" = 1'-0"ID100
DEMOLITION PLAN - C300210
SCALE: 1/8" = 1'-0"ID100
DEMOLITION PLAN - C36014
SCALE: 1/8" = 1'-0"ID100
DEMOLITION PLAN - C300515
SCALE: 1/8" = 1'-0"ID100
DEMOLITION PLAN - A422A16
SCALE: 1/8" = 1'-0"ID100
DEMOLITION PLAN - A75517
SCALE: 1/8" = 1'-0"ID100
DEMOLITION PLAN - A77018
SCALE: 1/8" = 1'-0"ID100
DEMOLITION PLAN - A77519
SCALE: 1/8" = 1'-0"ID100
DEMOLITION PLAN - B71120
SUBSTRATE. PREP PER
MANUF.
RECOMMENDATIONS
RESILIENT TRANSITION
STRIP; COLOR TO
MATCH ADJACENT
WALL BASE
EXISITNG CARPET TILE
RESILIENT FLOORING;
SEE FINISH SCHEDULE
AND KEY
RESILIENT REDUCER
STRIP, COLOR TO
MATCH ADJACENT
WALL BASE
RESILIENT FLOORING,
SEE FINISH KEY
EXISTING FLOORING
SUBSTRATE. PREP PER
MANUF.
RECOMMENDATIONS
SUBSTRATE. PREP PER
MANUF.
RECOMMENDATIONS
RESILIENT TRANSITION
STRIP; COLOR TO
MATCH ADJACENT
WALL BASE
EXISTING RESILIENT
FLOORING
RESILIENT TILE; SEE
FINISH KEY
LUXURY VINYL TILE; SEE
FINISH SCHEDULE & KEY
EXISTING METAL
TRANSITION PIECE
EXISITNG PORCELAIN
FLOOR TILE
SUBSTRATE, PREP PER
MANUF.
RECOMMENDATIONS
VA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
STAMP
CONSULTANTS:
321 4 5 6 7 8 9 10
5/8/2023 1:06:27 PM
REPLACE DAMAGED
FLOORING
05/11/2023
FINISH KEY & DETAILS
IN100
AHVG
539-23-202
CINCINNATI MEDICAL CENTER
VA Station No:
BID DOCUMENTS
SCALE: 12" = 1'-0"IN100
CARPET TILE TO RESILIENT TILE FLOORING01
SCALE: 12" = 1'-0"IN100
RESILIENT FLOORING REDUCER02
SCALE: 12" = 1'-0"IN100
RESILENT TILE TO EXISTING03
INTERIOR FINISH KEY
TAG MATERIAL MANUFACTURER STYLE COLOR REMARKS
09 65 13 RESILIENT BASE AND ACCESSORIES
RWB-1 RUBBER WALL BASE JOHNSONITE MW-XX-F8 MILLWORKS MANDALAY FAWN 80 8" HIGH, CORRIDORS AND WAITING ROOMS
RWB-2 RUBBER WALL BASE JOHNSONITE RUBBER COVE BASE FAWN 80 4" HIGH, OFFICES AND ADMINISTRATIVE
RWB-3 RUBBER WALL BASE JOHNSONITE RUBBER COVE BASE FAWN 80 6" HIGH, PATIENT CARE AREAS
09 65 19 RESILIENT TILE FLOORING
RTF-1 RESILIENT TILE FLOORING TARKETT ID LATITUDE WOOD 3307 EUROPEAN CHERRY
09 91 00 PAINTING
PT-1 PAINT BENJAMIN MOORE INTERIOR ACRYLIC LATEX - LOW VOC LRV:70 WIND'S BREATH 981 WALLS - GLOSS LEVEL 3 - EGGSHELL
PT-2 PAINT BENJAMIN MOORE INTERIOR ACRYLIC LATEX - LOW VOC LRV:70 WIND'S BREATH 981 CEILING - GLOSS LEVEL 1 - FLAT
SCALE: 12" = 1'-0"IN100
PORCELAIN TILE TO RESILIENT TILE FLOORING04
FD
MEDICAL
RECORDS
STORAGE
C002
RTF-1
RWB-2
IN100
IN100
NOTE:
EXISTING RESILIENT
TILE FLOORING TO
REMAIN
AUD. BOOTH
C037A
RTF-1
RWB-3
AUD. BOOTH
C037
RTF-1
RWB-3
DECEDENT
AFFAIRS
A144
RTF-1
RWB-2
CONF. ROOM
A144A
RTF-1
RWB-2
IN100
IN100
OFF.
B135
RTF-1
RWB-2
IN100
STUDENT OFF.
A251
RTF-1
RWB-2
IN100
CHIEF OFF.
A321
RTF-1
RWB-2
IN100
READING
ROOM
A257
RTF-1
RWB-2
READING
ROOM
A258
RTF-1
RWB-2
ADM.
A259
RTF-1
RWB-2
CHIEF
RADIOLOGY
A260
RTF-1
RWB-2
ADM. ASST.
A261
RTF-1
RWB-2
OFF.
A262
RTF-1
RWB-2
READING
ROOM
A264
RTF-1
RWB-2
READING
ROOM
A262A
RTF-1
RWB-2
IN100
RESIDENT
READING
ROOM
A263
RTF-1
RWB-2
VIEWING
A256
RTF-1
RWB-2
VASC. LAB
A347
RTF-1
RWB-3
PT-1
PT-2
IN100
IN100
IN100
PATCH GYP. BD. WHERE
EXISTING WALLS ARE
REMOVED TO PREP FOR
NEW PAINT FINISH
OFF.
A353
RTF-1
RWB-2
IN100
FAMILY
WAITING
B326
RTF-1
RWB-1
RECEPTION
B327
RTF-1
RWB-2
IN100
ICU DIR. OFF.
C314
RTF-1
RWB-2
IN100
FINISH PLAN LEGEND
ROOM NAMEOFFICE
XXXX
RTF-1
RWB-1
ROOM NUMBER
FLOOR FINISH
BASE FINISH
GENERAL NOTE
1. REFER TO INTERIOR FINISH KEY & DETAILS ON SHEET IN100.
2. CONTINUE ALL NEW INTERIOR FINISHS INTO ADJACENT
CLOSETS, ETC.
3. TRANSITIONS BETWEEN DIFFERENT HEIGHT FLOORING
MATERIALS REQUIRE AN ADA-COMPLIANT RESILIENT
TRANSITION STRIP.
4. CONTINUE RESILIENT WALL BASE AROUND ALL CASEWORK
BASE/TOE-KICKS U.N.O.
FLOORING TRANSITION
VASC. LAB
A300
RTF-1
RWB-3
OFFICE
A301
RTF-1
RWB-2
CHIEF DIET.
A302
RTF-1
RWB-2
DIET SEC.
A303
RTF-1
RWB-2
VASC. LAB
A379
RTF-1
RWB-3
IN100
IN100
IN100
IN100
IN100
EMS
C360
RTF-1
RWB-2
IN100
CONSULT.
C3005
RTF-1
RWB-2
C3005A
RTF-1
RWB-2
IN100
WAITING
C3002
RTF-1
RWB-1
IN100
IN100
SOCIAL
WORKER
A422A
RTF-1
RWB-2
IN100
OFFICE #8
A755
RTF-1
RWB-2
IN100
TESTING
A770
RTF-1
RWB-2
IN100
OFFICE #18
A775
RTF-1
RWB-2
IN100
OFF.
B711
RTF-1
RWB-2
IN100
VA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
STAMP
CONSULTANTS:
321 4 5 6 7 8 9 10
5/8/2023 1:06:28 PM
REPLACE DAMAGED
FLOORING
05/11/2023
FINISH PLANS
IN101
AHVG
539-23-202
CINCINNATI MEDICAL CENTER
VA Station No:
BID DOCUMENTS
SCALE: 1/8" = 1'-0"IN101
FINISH PLAN - C00201
SCALE: 1/8" = 1'-0"IN101
FINISH PLAN - C037/C037A02
SCALE: 1/8" = 1'-0"IN101
FINISH PLAN - A144A03
SCALE: 1/8" = 1'-0"IN101
FINISH PLAN - B13504
SCALE: 1/8" = 1'-0"IN101
FINISH PLAN - A25105
SCALE: 1/8" = 1'-0"IN101
FINISH PLAN - A32106
SCALE: 1/8" = 1'-0"IN101
FINISH PLAN - A257-A26413
SCALE: 1/8" = 1'-0"IN101
FINISH PLAN - A34707
SCALE: 1/8" = 1'-0"IN101
FINISH PLAN - A35308
SCALE: 1/8" = 1'-0"IN101
FINISH PLAN - B326/B32712
SCALE: 1/8" = 1'-0"IN101
FINISH PLAN - C31409
Revisions Date
SCALE: 1/8" = 1'-0"IN101
FINISH PLAN - A300-A37911
SCALE: 1/8" = 1'-0"IN101
FINISH PLAN - C36010
SCALE: 1/8" = 1'-0"IN101
FINISH PLAN - C300515
SCALE: 1/8" = 1'-0"IN101
FINISH PLAN - C300214
SCALE: 1/8" = 1'-0"IN101
FINISH PLAN - A422A16
SCALE: 1/8" = 1'-0"IN101
FINISH PLAN - A75517
SCALE: 1/8" = 1'-0"IN101
FINISH PLAN - A77018
SCALE: 1/8" = 1'-0"IN101
FINISH PLAN - A77519
SCALE: 1/8" = 1'-0"IN101
FINISH PLAN - B71120
B R A D E N S .
C O X
6201070323
NO.
ENGINEER
S T
A
T E
O F M I C H
I
G A
N
R E
E N
I G
N
E
LANOISSEFORP
D
E S
N E
C I
L
WM
M
S
M
CHWS
CWV
CA
CD
CDR
CWR
CWS
CW
F-CW
H-CW
S-CW
HW
HW 140°
HW-R
HW-R 140°
GV
GW
HWR
HWS
G
OV
OW
PD
V
SS
SHWR
SHWS
STM
SD
OSD
(E)
CHWR CHILLED WATER RETURN
CHILLED WATER SUPPLY
COMBINATION WASTE & VENT
COMPRESSED AIR
CONDENSATE DRAINAGE
CONDENSATE RETURN
CONDENSER WATER RETURN
CONDENSER WATER SUPPLY
DOMESTIC COLD WATER
FILTERED COLD WATER
HARD COLD WATER
SOFT COLD WATER
HOT WATER
HOT WATER 140°
HOT WATER RECIRCULATION
HOT WATER RECIRCULATION 140°
GREASE VENT
GREASE WASTE
HEATING WATER RETURN
HEATING WATER SUPPLY
NATURAL GAS
OIL VENT
OIL WASTE
PUMP DISCHARGE
SANITARY VENT
SANITARY SEWER
SOLAR HOT WATER RETURN
SOLAR HOT WATER SUPPLY
STEAM
STORM DRAINAGE
OVERFLOW STORM DRAINAGE
REF-L
REF-S
REFRIGERANT-LIQUID
REFRIGERANT-SUCTION
2"
4"
REF-HG REFRIGERANT-HOT GAS
PLUMBING AND PIPING SYMBOLS
KEYNOTE
CONTINUATION SYMBOL
NUMBER OF SHEET WHERE DETAIL APPEARS
NUMBER OF DETAIL ON SHEET
REVISION NUMBER - SHOWN ON PLANS
GENERAL SYMBOLS
ROOM NAME AND NUMBER
POINT WHERE DISCONNECT/DEMOLITION OCCURS
AT EXISTING
EXISTING PIPE TAG
ITEM TO BE DEMOLISHED
AREA NOT IN CONTRACT
PIPING BEING DEMOLISHED
ABOVE GROUND PIPING
PIPE SIZE TAG (DIAMETER)
BELOW GROUND PIPING
PIPE INVERT ELEVATION TAG
PG PROPANE GAS
Room
1/8" / 12" SLOPE
RO REVERSE OSMOSIS WATER
IW INDIRECT WASTE
0 SF
6" SD-1
Ø ROUND
ABV ABOVE
AC AIR CONDITIONING
AD AREA DRAIN
ADD ADDENDUM
AFF ABOVE FINISHED FLOOR
AFUE ANNUAL FUEL UTILIZATION
EFFICIENCY
ALT ALTERNATE
AP ACCESS PANEL
ARCH ARCHITECT/ARCHITECTURAL
BFF BELOW FINISHED FLOOR
BLW BELOW
BTU BRITISH THERMAL UNITS
BTUH BRITISH THERMAL UNITS PER
HOUR
CAP CAPACITY
CB CATCH BASIN
CFM CUBIC FEET PER MINUTE
CLG CEILING
CO CLEAN OUT
CW COLD WATER
D DEGREE
DB DRY BULB
DIA DIAMETER
DN DOWN
DW DISTILLED WATER
EA EACH
EAT ENTERING AIR TEMPERATURE
ELEC ELECTRICAL
EQUIP EQUIPMENT
EWC ELECTRIC WATER COOLER
EWT ENTERING WATER TEMPERATURE
E/A EXHAUST AIR
EXIST EXISTING
F DEGREES FAHRENHEIT
FCO FLOOR CLEAN OUT
FD FLOOR DRAIN
FDC FIRE DEPARTMENT CONNECTION
FL FLOOR
FO FUEL OIL
FOV FUEL OIL VENT
FOR FUEL OIL RETURN
FOS FUEL OIL SUPPLY
FPM FEET PER MINUTE
FS FLOOR SINK
FT FOOT/FEET
FTR FIN TUBE RADIATION
GAL GALLON
GF GAS-FIRED
GC GENERAL CONTRACTOR
GPM GALLONS PER MINUTE
GW GREASE WASTE
HB HOSE BIB
HP HORSE POWER
HTG HEATING
HTR HEATER
HW HOT WATER
HYD HYDRANT
ID INDIRECT
IN INCH
INV INVERT
LB POUND
LB/HR POUNDS PER HOUR
LAT LEAVING AIR TEMPERATURE
LP LOW PRESSURE
LPG LIQUEFIED PETROLEUM GAS
LVR LOUVER
LWT LEAVING WATER
TEMPERATURE
M/A MIXED AIR
MAX MAXIMUM
MBH ONE THOUSAND BTU PER
HOUR
MCF ONE THOUSAND CUBIC FEET
MD MOTORIZED DAMPER
MECH MECHANICAL
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MTR MOTOR
MU/A MAKE-UP/AIR
NC NOISE CRITERIA
NC NORMALLY CLOSED
NIC NOT IN CONTRACT
NO NUMBER
NO NORMALLY OPEN
NTS NOT TO SCALE
O OXYGEN
O/A OUTSIDE AIR
ORD OVERFLOW ROOF DRAIN
PD PRESSURE DROP
PIV POST INDICATOR VALVE
PLBG PLUMBING
PRESS PRESSURE
PRV PRESSURE REDUCING VALVE
PSI POUNDS PER SQUARE INCH
PSIG POUNDS PER SQUARE INCH
GAUGE
PWR POWER
R DUCT RISER
R/A RETURN AIR
RCP RADIANT CEILING PANEL
RD ROOF DRAIN
REC RECESSED
RED REDUCER
RH RELATIVE HUMIDITY
RL/A RELIEF AIR
RM ROOM
RPM REVOLUTIONS PER MINUTE
RW RAIN WATER
SF SQUARE FOOT
S/A SUPPLY AIR
SAN SANITARY
SF SQUARE FOOT
SD SMOKE DAMPER
SM SURFACE MOUNT
SP STANDPIPE
SP STATIC PRESSURE
STM STEAM
T THERMOSTAT
TD TEMPERATURE DROP
TDR TRENCH DRAIN
TEMP TEMPERATURE
TYP TYPICAL
UG UNDERGROUND
VAC VACUUM
V VENT
VAV VARIABLE AIR VOLUME
VENT VENTILATION
VTR VENT THROUGH ROOF
W WASTE
WB WET BULB
WCO WALL CLEAN OUT
WH WALL HYDRANT
ABBREVIATIONS
AC AIR CONDITIONING UNIT
ACCU AIR COOLING CONDENSING
UNIT
AHU AIR HANDLING UNIT
AS AIR SEPARATOR
B BOILER
CH CHILLER
CT COOLING TOWER
CUH CABINET UNIT HEATER
CHWP CHILLED WATER PUMP
DBP DOMESTIC WATER BOOSTER PUMP
DC DUCT MOUNTED COIL
DCP DOMESTIC WATER CIRCULATING
PUMP
EF EXHAUST FAN
EDC ELECTRIC DUCT COIL
ET EXPANSION TANK
EWH ELECTRIC WATER HEATER
FCU FAN COIL UNIT
FP FIRE PUMP
GI GREASE INTERCEPTOR
GRV GRAVITY ROOF
VENTILATOR
HWP HEATING WATER PUMP
HRU HEAT RECOVERY UNIT
PRV POWER ROOF VENTILATOR
RE RETURN/EXHAUST FAN
RTU ROOFTOP UNIT
SP SUMP PUMP
UH UNIT HEATER
WH WATER HEATER
EQUIPMENT ABBREVIATIONS
4" FD-1FLOOR DRAIN 4" AD-6 AREA DRAIN
4" FS-4FLOOR SINK
4" SD-29 DECK DRAIN4" FD-3PFLOOR DRAIN
6 DFU
4" FD-13
HUB DRAIN
DRAIN TAGS
FIXTURE
UNITS
FLOW
CONTROL
DRAIN
4" SD-12
COMBINATION
DRAINS
STORM DRAIN4" SD-15
PIPE ACCESSORY TAGS
DOMESTIC WATER METER
BALANCING VALVE
1/4 TURN BALL VALVE
CHECK VALVE
3-WAY MIXING VALVE
MOTORIZED CONTROL VALVE
3 WAY MOTORIZED CONTROL
VALVE
PRESSURE REDUCING VALVE
REFRIGERANT SOLENOID
VALVE
BUTTERFLY VALVE
2" BUTTERFLY
WATER CLOSET
- WALL HUNG -
ADA
WC-1
U-1
PLUMBING FIXTURE TAGS
TYPE (SEE SCHEDULE)
WC-1A
CAP
GWR
GWS
GEOTHERMAL WATER RETURN
GEOTHERMAL WATER SUPPLY
GATE VALVE
P
3-WAY AIRMOTOR
CONTROLLER
ANGLE GLOBE VALVE
ANGLE HOSE VALVE
DIAPHRAGM VALVE
GLOBE VALVE
S
HOSE GLOBE VALVE
LOCK SHIELD VALVE
NEEDLE VALVE
PLUG VALVE
QUICK OPENING VALVE
SPRING CHECK VALVE
SWING GATE CHECK VALVE
TEMP PRESSURE RELIEF VALVE
* NOTE *
ALL GENERAL NOTES ON THIS SHEET ARE TO BE APPLIED TO ALL OTHER DRAWINGS
IN THIS SET. THE SYMBOLS AND ABBREVIATIONS SHOWN ON THIS SHEET MAY OR
MAY NOT BE USED IN THIS SET OF DRAWINGS.
POINT WHERE NEW CONNECTS TO EXISTING
(D)
2"
4"
DRAIN SIZE
PIPE RISE
PIPE DROP
PIPE TEE REDUCING 45
DEGREE TEE
DEGREE
TEE
PIPE SLOPE TAG
TYPE (SEE SCHEDULE)
INVERT: -105' - 1"
"P" - INDICATES
PRIMER
CONNECTION
ROOF AREA SERVED BY DRAIN
2" DOM. WM
2" BALANCING
2" SHUTOFF
2" CHECK
2" TMV
2" M-CONTROL
2" 3-WAY CONTROL
2" PRV
3/8" SOLENOID
2" BUTTERFLY
1 DFU
LAVWA
0.75 CWFU
0.75 HWFU
LAVWA
FIXTURE UNITS
PIPE
ACCESSORY
TAG
TYPE (SEE SCHEDULE)
CAP
WCO
PLUGH
H
I
I
6 6
7 7
8a 8a
9 9
Jb
Jb
8 8
VASC. LAB
A347
GENERAL PROJECT NOTES
1 REMOVE ALL UNUSED PIPING, DUCTWORK AND ACCESSORIES.
2 THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING,
PRIOR TO FINAL BID, ALL EXISTING CONDITIONS FOR PLUMBING AND
MECHANICAL SYSTEMS WITHIN TENANT SPACE AND WITHIN CLOSE PROXIMITY OF
TENANT SPACE.
3 THE MECHANICAL CONTRACTOR SHALL VISIT THE SITE, PRIOR TO FINAL BIDDING,
AND VERIFY ALL EXISTING SITE CONDITIONS. PROVIDE ALL MATERIAL AND
COMPONENTS AS NEEDED TO BRING THE UNITS TO FULL COMPLIANCE OF THE
OWNER'S CRITERIA AND LOCAL AUTHORITY HAVING JURISDICTION.
4 WHERE FLOOR DRAINS OCCUR WITHIN THE LIMITS OF CONSTRUCTION, PREVENT
CONSTRUCTION DEBRIS FROM ENTERING DRAIN BODY BY SEALING DRAIN
OPENING PRIOR TO START OF WORK. UNSEAL DRAINS AT COMPLETION OF
CONSTRUCTION.
5 THE CONTRACTOR SHALL BE FAMILIAR WITH ALL THE CONDITIONS BOTH EXISTING
AND THOSE ILLUSTRATED BY THESE DOCUMENTS AS WELL AS THOSE WHICH CAN
BE REASONABLY ANTICIPATED INCLUDING, BUT NOT LIMITED TO ARCHITECTURAL,
ELECTRICAL, VENTILATION, PLUMBING, AND OTHER SYSTEMS INVOLVED ON THIS
PROJECT.
6 FINAL PRODUCT SHALL BE A COMPLETE AND FUNCTIONING SYSTEM, AND SHALL
CONFORM TO ALL REQUIREMENTS OF APPLICABLE FEDERAL, STATE, AND LOCAL
CODES, INCLUDING BUT NOT LIMITED TO THE INTERNATIONAL BUILDING CODE
AND INTERNATIONAL MECHANICAL CODE.
7 LOCATE DUCTWORK, PIPING AND MECHANICAL EQUIPMENT AWAY FROM THE
SPACE ABOVE ELECTRICAL PANELS. TRANSFORMERS AND OTHER ELECTRICAL
EQUIPMENT.
8 PENETRATIONS OF RATED ASSEMBLIES SHALL BE FIRE STOPPED. FIRE STOPPING
SHALL BE AN APPROVED MATERIAL AS PRESCRIBED IN CSFM STANDARD 43-1
AND SHALL BE U.L. LISTED.
9 MAINTAIN CLEAR ACCESS TO SERVICE EQUIPMENT AND OTHER ACCESSORIES
REQUIRING SERVICE, VISUAL INSPECTION OR HAND OPERATION. WHERE
INDICATED OR REQUIRED, PROVIDE ACCESS PANELS OF THE TYPE SELECTED TO
SUIT MATERIALS IN WHICH INSTALLED.
10 INSTALL ALL EQUIPMENT IN ACCORDANCE WITH THE RESPECTIVE
MANUFACTURER'S WRITTEN INSTALLATION INSTRUCTIONS, AT A LEVEL OF QUALITY
AND WORKMANSHIP CONSISTENT WITH THE SPECIFICATIONS.
11 LOCATIONS OF PIPING, DUCTWORK AND EQUIPMENT AS INDICATED ON THE
DRAWING, ARE APPROXIMATE AND SUBJECT TO MINOR ADJUSTMENTS IN THE
FIELD. WORK SHALL BE COORDINATED WITH ALL OTHER TRADES TO AVOID
INTERFERENCE IN THE FIELD.
12 THE CONTRACTOR'S WORK SCHEDULE SHALL BE SUBMITTED TO AND APPROVED
BY THE OWNER.
13 PRIOR TO STARTING WORK, SUBMIT SHOP DRAWINGS FOR ALL MECHANICAL
EQUIPMENT, PLUMBING FIXTURES, AND DIFFUSERS.
14 CONTRACTOR SHALL OBTAIN AND PAY FOR ALL NECESSARY PERMITS AND SHALL
ARRANGE FOR ALL INSPECTIONS AS REQUIRED.
15 PROVIDE ONE YEAR WARRANTY FOR ALL WORKMANSHIP AND MATERIALS AFTER
THE DATE OF FINAL ACCEPTANCE.
16 EACH DETAIL INCLUDED IN THIS SET OF DOCUMENTS APPLIES TO THIS PROJECT
REGARDLESS IF EACH DETAIL HAS BEEN REFERENCED ON THE PLANS OR NOT.
GENERAL PLUMBING NOTES
1 FIELD VERIFY ALL NEW WATER, WASTE, AND VENT PIPING CONNECTIONS AND
PROVIDE NEW CONNECTIONS AS REQUIRED FOR PROPERLY OPERATING
SYSTEMS.
PLUMBING SHEET LIST
SHEET DESCRIPTION
P001 PLUMBING GENERAL INFO & SYMBOL LEGEND, AND THIRD FLOOR
DEMOLITION PLAN
VA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
STAMP
CONSULTANT
321 4 5 6 7 8 9 10
REPLACE DAMAGED
FLOORING
5/11/2023
PLUMBING GENERAL INFO &
SYMBOL LEGEND, AND THIRD
FLOOR DEMOLITION PLAN
P001
SMBC
539-23-202
CINCINNATI MEDICAL CENTER
VA Station No:
BID DOCUMENTS
NORTH
SCALE: 1/4" = 1'-0"
THIRD FLOOR PLUMBING DEMOLITION PLAN
KEYNOTES
1 REMOVE EXISTING WATER CLOSET AND ASSOCIATED PIPING
BACK TO MAIN AND CAP.
PLUMBING DEMOLITION NOTES
1 THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE
LOCAL, STATE AND/OR REGULATORY AGENCIES, CODES AND
REGULATIONS FOR NEW WORK.
2 CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION
OF THEIR WORK WITH OTHER TRADES AND WITH THE
CONSTRUCTION MANAGER.
3 VERIFY ALL CONDITIONS IN FIELD BEFORE START OF
CONSTRUCTION. NOTIFY ARCHITECT/ENGINEER OF
DISCREPANCIES BETWEEN DRAWINGS AND ACTUAL FIELD
CONDITIONS.
4 COORDINATE ALL WORK WITH APPROPRIATE TRADES.
5 COORDINATE ANY REQUIRED SHUTDOWN OF SERVICES OR
EQUIPMENT WITH OWNER'S REPRESENTATIVE, MINIMIZE
INTERRUPTION OF EXISTING SERVICES. VERIFY ALL SYSTEMS
BEFORE STARTING DEMOLITION TO ASSURE OTHER AREAS WILL
NOT LOOSE SERVICE. AREAS SUCH AS THE SECOND FLOOR
KITCHEN ARE CRITICAL TO THE FACILITIES OPERATION.
6 COORDINATE FLOOR, WALL, AND ROOF PENETRATIONS ETC.
WITH ARCHITECTURAL TRADES. PROVIDE TEMPORARY WATER
TIGHT SEAL FOR ALL EXTERIOR WALL AND ROOF PENETRATION
AS NECESSARY.
7 COORDINATE ALL FLOOR CUTTING WITH STRUCTURAL TRADES
BEFORE CUTTING.
8 HOLES AND PENETRATIONS IN RATED WALLS SHALL BE PATCHED
WITH APPROPRIATE FIRESTOP MATERIALS FOR RATING REQUIRED.
9 NO ITEMS ABANDONED IN PLACE.
10 ALL ITEMS DEMOLISHED SHALL BE REMOVED AND REMAINING
OPEN SYSTEMS SHALL BE PATCHED, CAPPED AND SEALED TO
PROVIDE A FINISHED SYSTEM.
11 DEMOLISHED PLUMBING LINE SHALL NOT BE ALLOWED TO
REMAIN OPEN, CAP AND PROTECT TO AVOID CONTAMINATION
TO AND FROM THE SURROUNDING AREAS.
12 ALL SYSTEMS OPENED DURING DEMOLITION SHALL BE CLOSED
AND RETURNED TO OPERATION BY END OF SHIFT, NO SYSTEMS
ALLOWED TO BE LEFT OPEN WHEN NOT BEING SUPERVISED BY
CONTRACTOR RESPONSIBLE FOR THAT WORK TRADE.
5/10/23
B R A D E N S .
C O X
6201070323
NO.
ENGINEER
S T
A
T E
O F M I C H
I
G A
N
R E
E N
I G
N
E
LANOISSEFORP
D
E S
N E
C I
L
J
K O
S T
T D
D
EM
P
P
J R
E T
H T
F
F
F F
D
F P
FR
L6 -3
CLNG
J
F S
D
V
M
ES
ML
DC
CL
CR
MD
E
B
D
S
P
N
TV
N
N
IG
G
FI
G
FI
W
P
TP U
SB
A C
EW
C
G
FI
OS
XX-1 XX-1 XX-1
XX-1
XX-1
ELECTRICAL SYMBOL NOTES
EXIT LIGHTS. STEM INDICATES WALL MOUNTING. NO STEM INDICATES
CEILING MOUNTING. SHADED AREA INDICATES ILLUMINATED FACE(S).
ARROW INDICATES DIRECTIONAL ARROW ON ILLUMINATED FACE(S).
THE CIRCUIT DESIGNATION IS INDICATED BY A NUMBER. EXAMPLE: THE
WALL MOUNTED EXIT LIGHT TYPE "E1" WITH SINGLE FACE AND
DIRECTIONAL ARROW IS CONNECTED TO CIRCUIT 1.
DEVICES. THE CIRCUIT DESIGNATION IS INDICATED BY A NUMBER.
THE SWITCH DESIGNATION IS INDICATED BY A LOWER CASE LETTER.
EXAMPLE: SPLIT DUPLEX RECEPTACLE IS CONNECTED TO CIRCUIT 1
AND ONE RECEPTACLE OUTLET IS CONTROLLED BY SWITCH "d".
THE CONTROL DEVICE DESIGNATION IS INDICATED BY A LOWER CASE
LETTER. EXAMPLE: SINGLE POLE SWITCH "d" TO CONTROL LIGHTING
FIXTURES INDICATED BY "d".
WALL BOX DIMMER WITH SIZE AS INDICATED AT DEVICE. EXAMPLE: 600
WATT WALL BOX DIMMER TO CONTROL LIGHTING FIXTURES INDICATED
BY "e". SEE SPECIFICATIONS FOR WATTAGE IF NOT INDICATED.
SPECIAL CONNECTIONS. THE EQUIPMENT IS INDICATED BY A NUMBER
IN A CIRCLE. SEE THE MOTOR AND EQUIPMENT SCHEDULE FOR THE
LOAD DESCRIPTION AND TYPE OF CONNECTION. THE CIRCUIT
DESIGNATION IS INDICATED BY NUMBER(S) ADJACENT TO THE SYMBOL.
EXAMPLE: EQUIPMENT NO. ELEC-1; 1 PHASE CONNECTION TO
CIRCUITS 2, 4.
MOTOR CONNECTIONS. THE MOTOR IS INDICATED BY A NUMBER
WITHIN OR CHARACTERS ADJACENT TO THE MOTOR SYMBOL. SEE
THE MOTOR AND EQUIPMENT SCHEDULE FOR THE MOTOR
DESCRIPTION AND ELECTRICAL REQUIREMENTS.
TRANSFORMERS. THE TRANSFORMER TYPE IS INDICATED BY A NUMBER
FOLLOWING THE UPPER CASE LETTER "T". SEE THE TRANSFORMER
SCHEDULE OR THE SINGLE LINE DIAGRAM FOR THE TRANSFORMER
DESCRIPTION AND REQUIREMENTS. EXAMPLE: TRANSFORMER TYPE "T1".
PANELBOARDS. PANELBOARD DOORS MAY BE SHOWN TO
INDICATE OPENING SIDE OF RECESSED PANELBOARDS. SEE
PANELBOARD IDENTIFICATION FOR DESIGNATION CODES.
CONDUIT SHOWN WITHOUT SLASH MARKS SHALL CONTAIN 1 # 12
CONDUCTOR PER PHASE, NEUTRAL, AND GROUND IN 1/2" CONDUIT
UNLESS SPECIFIC EQUIPMENT REQUIRES A DIFFERENT SIZE.
CONDUIT SHOWN SHALL CONTAIN 1 # 10 CONDUCTOR PER PHASE IN
ELECTRICAL CODE SIZED MINIMUM CONDUIT UNLESS A CONDUCTOR
AND CONDUIT SIZE IS SHOWN ADJACENT.
HOME RUN TO BRANCH CIRCUIT PANELBOARD. THE PANELBOARD
DESIGNATION IS SHOWN ADJACENT TO THE HOME RUN ARROW AS A
NUMERATOR AND THE CIRCUIT DESIGNATION IS SHOWN AS THE
DENOMINATOR. CIRCUIT BREAKER SIZES (AMPS/NUMBER OF POLES)
ARE SHOWN IN THE PANELBOARD SCHEDULE WITH THE
CORRESPONDING PANELBOARD AND CIRCUIT DESIGNATION.
EXAMPLE: HOME RUN TO PANELBOARD P4N-102; CIRCUITS 1, 3, 5.
SYMBOLSYMBOL SYMBOLDESCRIPTION DESCRIPTION DESCRIPTION
FIRE ALARM HORN W/STROBE
FIRE ALARM BELL
FIRE ALARM BELL W/STROBE
FIRE ALARM CHIME W/STROBE
THERMOSTAT
HUMIDISTAT
ELECTRONIC TIMER
RELAY
CABLE TAP BOX
SAFETY DISC. SWITCH (FUSED)
SAFETY DISC. SWITCH (NON-FUSED)
COMB. MOTOR STARTER (FUSED)
TRANSFORMER
FLOOR JUNCTION BOX
JUNCTION BOX
UTILITY SERVICE POWER POLE
STATIC GROUND RECEPTACLE
SURGERY SERVICE COLUMN
POWER POLE (OPEN OFFICE STYLE)
MULTIOUTLET ASSEMBLY
RECEPTACLE ON CORD REEL
FLOOR DUPLEX RECEPT.
FOURPLEX RECEPTACLE ON
EMERGENCY CIRCUIT
FOURPLEX RECEPTACLE
SINGLE RECEPT.
PUSH BUTTON
TIME DELAY SWITCH
TIMER SWITCH
OCCUPANCY SENSOR
DIMMER SWITCH
SWITCH W/PILOT
KEYED SWITCH
4-WAY SWITCH
3-WAY SWITCH
SINGLE POLE SWITCH
BUS DUCT W/ PLUG IN DISCONNECT
PS - D2
T1
PANELBOARD IDENTIFICATION
KEYED NOTE (SEE SCHEDULE)
NUMBER OF SHEET WHERE DETAIL APPEARS
NUMBER OF DETAIL ON SHEET
REVISION NUMBER - SHOWN ON PLANS
ROOM NAME AND NUMBER
ITEM TO BE
REMOVED
AREA NOT IN
CONTRACT
IDENTITY (SEE SCHEDULE)
EXISTING TO REMAIN RELOCATED DEMOLISHED
d ee
2,4
T1
FLOOR CLEARANCE AREA
CONDUIT IN CEILING, FLOOR OR WALL AS REQUIRED BY FIELD
CONDITIONS
CONDUIT IN FLOOR
P4N12
1. EQUIPMENT DESIGNATION:
L = LIGHTING
P = POWER
D = DISTRIBUTION
S = SWITCHBOARD
M = MOTOR CONTROL CENTER
R = RELAY PANEL
2. VOLTAGE DESIGNATION:
1 = 120/240V - 1PH
2 = 240V - 3PH
3 = 208Y/120V - 3PH
4 = 480Y/277V - 3PH
5 = 120/208 - 1PH
6 = SPECIAL
3. SYSTEM DESIGNATION:
N = NORMAL
E = EMERGENCY
C = POWER CONDITIONED
U = UNINTERRUPTIBLE POWER SOURCE
4. FLOOR DESIGNATION:
B = BASEMENT
G = GROUND
1 = FIRST FLOOR
2 = SECOND FLOOR
ETC.
5. PANEL NO. DESIGNATION:
1 = PANELBOARD #1
2 = PANELBOARD #2
3 = PANELBOARD #3
ETC.
FIRE ALARM PULL STATION
FIRE ALARM DOOR HOLDER
FIRE ALARM DOOR CLOSER
FIRE ALARM SHUT DOWN RELAY
CEILING DATA OUTLET
FLOOR DATA OUTLET
# OF VOICE AND # OF DATA PORTS
EXAMPLE 1V2D = 1 VOICE, 2 DATA
P4N-102
1, 3, 5
#10
#12
EXISTING TO REMAIN
EXISTING TO BE REMOVED
NEW
GRAPHICAL REPRESENTATION OF PHASING, TYPICAL FOR ALL
SYMBOLS.
CEILING DUPLEX RECEPT.
SPECIAL RECEPTACLE
CEILING JUNCTION BOX
FLOOR TELEPHONE OUTLET
(MOUNTING HEIGHT)
CLNG
ELEC-1
Room
FIRE ALARM SPEAKER W/STROBE
EXIT LIGHT, WALL-MOUNTED,
SHADING AND ARROWS INDICATE
FACES AND DIRECTION
WALL-MOUNTED FIXTURES, TYPICAL
EXW1
LIGHTING FIXTURE TAG DESCRIPTORS:
TOP VALUE: FIXTURE TYPE ID.
BOTTOM VALUE, NUMBER: CIRCUIT NUMBER, REFER TO
DRAWINGS FOR PANEL.
BOTTOM VALUE, LOWERCASE LETTER: SWITCH DESIGNATION.
ABSENCE OF A SWITCH ID INDICATES FIXTURE IS CONTROLLED BY THE
ONLY SWITCH IN THE SPACE.
"x" IN PLACE OF THE SWITCH ID INDICATES NIGHT LIGHT, UNSWITCHED.
S3
1d
ELECTRIC STRIKE
MAGNETIC LOCK
COMBINATION LOCK
DOOR CONTACT
CARD READER
SECURITY KEYPAD
MOTION DETECTOR
NURSE CALL EMERG. STATION
NURSE CALL CODE BLUE STATION
NURSE CALL DUTY STATION
NURSE CALL STAFF STATION
NURSE CALL PATIENT STATION
NURSE CALL DOME LIGHT
(1-COLOR)
TELEPHONE OUTLET
VOICE/DATA OUTLET
DOOR BELL
DOOR BUZZER
DOOR CHIME
DOOR SIGNAL
VOLUME CONTROL
MICROPHONE OUTLET
1V 2D
CATV OUTLET
TV OUTLET
NURSE CALL DOME LIGHT
(4-COLORS)
NURSE CALL DOME LIGHT
(2-COLORS)
AUTO DOOR PUSH PAD
EMERGENCY LIGHTING UNIT, WALL-
MOUNTED, REMOTE BATTERY
EMERGENCY LIGHTING UNIT, WALL-
MOUNTED, INTEGRAL BATTERY
EMERGENCY LIGHTING UNIT, CEILING-
MOUNTED, INTEGRAL BATTERY
EMERGENCY LIGHTING UNIT, CEILING-
MOUNTED, REMOTE BATTERY
LIGHTING FIXTURES, TYPICAL,
RECTANGULAR FILLED CIRCLES
INDICATE RECESSED, OPEN CIRCLES
INDICATE SURFACE
DIAGONAL LINE INDICATES LENSED
OUTER DOTS INDICATE SUSPENDED
LIGHTING FIXTURES, TYPICAL, ROUND
CENTER DOT INDICATES PENDANT
DIAGONAL LINE INDICATES LENSED
CHEVRON INDICATES WALL WASH
STRIP FIXTURE
DIRECTIONAL LIGHT, TRACK, FLOOD
EXIT LIGHT, CEILING-MOUNTED,
SHADING AND ARROWS INDICATE
FACES AND DIRECTION
LINEAR LIGHT, TAPE LIGHT
EXIT/ELU COMBO
DIAGONAL HATCH INDICATES LIGHT
ON A CRITICAL CIRCUIT
SOLID HATCH INDICATES LIGHT ON
AN EMERGENCY OR LIFE SAFETY
CIRCUIT
POLE/AREA LIGHTS
POST-TOP AREA LIGHT
BOLLARD LIGHT
SPRINKLER FLOW SWITCH
SPRINKLER VALVE TAMPER SWITCH
DUCT SMOKE DETECTOR
THERMAL DETECTOR
ELECTRICAL SYMBOL LEGEND
# OF COLORS.
NEMA CONFIGURATION
DUPLEX RECEPTACLE ON
EMERGENCY CIRCUIT
DUPLEX ISOLATED GROUND RECEPT.
SPLIT DUPLEX RECEPTACLE
DUPLEX RECEPTACLE
GFI DUPLEX RECEPT. (FEED
THROUGH)
GFI WEATHERPROOF RECEPT.
DUPLEX RECEPT.
TAMPER-PROOF DUPLEX
RECEPTACLE
DUPLEX RECEPTACLE
WATER COOLER RECEPTACLE
COORDINATE THE LOCATION WITH
THE EQUIPMENT SUPPLIER
GA GAUGE
GAL GALLON
GALV GALVANIZED
GC GENERAL CONTRACTOR
GEN GENERATOR
GFI GROUND FAULT CIRCUIT
INTERRUPTER
GFP GROUND FAULT PROTECTOR
GND GROUND
GRS GALVANIZED RIGID STEEL
(CONDUIT)
GYP BD GYPSUM BOARD
HOA HANDS-OFF-AUTOMATIC SWITCH
HORIZ HORIZONTAL
HP HORSEPOWER
HPF HIGH POWER FACTOR
HT HEIGHT
HTG HEATING
HTR HEATER
HV HIGH VOLTAGE
HVAC HEATING, VENTILATING AND AIR
CONDITIONING
G ISOLATED GROUND
IMC INTERMEDIATE METAL CONDUIT
INCAND INCANDESCENT
IR INFRARED
I/W INTERLOCK WITH
J-BOX JUNCTION BOX
KV KILOVOLT
KVA KILOVOLT-AMPERE
KVAR KILOVOLT-AMPERE REACTIVE
KW KILOWATT
KWH KILOWATT HOUR
LOC LOCATE OR LOCATION
LT LIGHT
LTG LIGHTING
LTNG LIGHTNING
LV LOW VOLTAGE
MAX MAXIMUM
MAG.S MAGNETIC STARTER
M/C MOMENTARY CONTACT
MC MECHANICAL CONTRACTOR
MCB MAIN CIRCUIT BREAKER
MCC MOTOR CONTROL CENTER
MDC MAIN DISTRIBUTION CENTER
MDP MAIN DISTRIBUTION PANEL
MFR MANUFACTURER
MFS MAIN FUSED DISCONNECT
SW
MH MANHOLE
MIC MICROPHONE
MIN MINIMUM
MISC MISCELLANEOUS
MLO MAIN LUGS ONLY
MMS MANUAL MOTOR STARTER
MOA MULTIOUTLET ASSEMBLY
MSP MOTOR STARTER
PANELBOARD
MSBD MAIN SWITCHBOARD
MT MOUNT
MT.C EMPTY CONDUIT
MTS MANUAL TRANSFER SWITCH
MTR MOTOR, MOTORIZED
N.C. NORMALLY CLOSED
NEC NATIONAL ELECTRICAL CODE
NEMA NATIONAL ELECTRICAL
MANUFACTURER'S
ASSOCIATION
NFDS NON-FUSED SAFETY
DISCONNECT SWITCH
NIC NOT IN CONTRACT
NL NIGHT LIGHT
N.O. NORMALLY OPEN
NPF NORMAL POWER FACTOR
NTS NOT TO SCALE
OH OVERHEAD
OL OVERLOADS
PA PUBLIC ADDRESS
PB PULL BOX OR PUSHBUTTON
PE PNEUMATIC ELECTRIC
PED PEDESTAL
PF POWER FACTOR
PH PHASE
PIV POST INDICATING VALVE
PNL PANEL
PP POWER POLE
PR PAIR
ELECTRICAL ABBREVIATIONS LIST
PRI PRIMARY
PROJ PROJECTION
PRV POWER ROOF VENTILATOR
PT POTENTIAL TRANSFORMER
PVC POLYVINYL CHLORIDE
(CONDUIT)
PWR POWER
QUAN QUANTITY
RCPT RECEPTACLE
REQD REQUIRED
RM ROOM
RSC RIGID STEEL CONDUIT
RTU ROOF TOP UNIT
SC SURFACE CONDUIT
SEC SECONDARY
SHT SHEET
SIM SIMILAR
S/N SOLID NEUTRAL
SPEC SPECIFICATION
SPKR SPEAKER
SP SPARE
SR SURFACE RACEWAY
SS STAINLESS STEEL
SSW SELECTOR SWITCH
S/S STOP/START PUSHBUTTONS
STA STATION
STD STANDARD
SURF SURFACE MOUNTED
SW SWITCH
SWBD SWITCHBOARD
SYM SYMMETRICAL
SYS SYSTEM
TEL TELEPHONE
TEL/DAT TELEPHONE/DATA
TERM TERMINAL
TL TWIST LOCK
TR TAMPER RESISTANT
T-STAT THERMOSTAT
TTC TELEPHONE TERMINAL
CABINET
TV TELEVISION
TVTC TELEVISION TERMINAL
CABINET
TYP TYPICAL
UC UNDER COUNTER
UE UNDERGROUND ELECTRICAL
UG UNDERGROUND
UH UNIT HEATER
UT UNDERGROUND TELEPHONE
UTIL UTILITY
UV ULTRAVIOLET
V VOLT
VA VOLT-AMPERES
VDT VIDEO DISPLAY TERMINAL
VERT VERTICAL
VFD VARIABLE FREQUENCY DRIVE
VOL VOLUME
W WATT
W/ WITH
WG WIRE GUARD
WH WATER HEATER
W/O WITHOUT
WP WEATHERPROOF
XFMR TRANSFORMER
XFR TRANSFER
∠ ANGLE
@ AT
▲ DELTA
' FEET
" INCHES
# NUMBER
Ø PHASE
C CENTER LINE
P PLATE
* NOTE *
ALL GENERAL NOTES ON THIS SHEET ARE TO BE APPLIED TO ALL OTHER
DRAWINGS IN THIS SET. THE SYMBOLS AND ABBREVIATIONS SHOWN ON THIS
SHEET MAY OR MAY NOT BE USED IN THIS SET OF DRAWINGS.
1P 1 POLE (2P, 3P, 4P, ETC.)
A AMPERE
AC ABOVE COUNTER
ACLG ABOVE CEILING
ADO AUTOMATIC DOOR OPENER
AF AMP FRAME
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFI ARC FAULT CIRCUIT
INTERRUPTER
AHU AIR HANDLING UNIT
AL ALUMINUM
ALT ALTERNATE
AMP AMPERE
AMPL AMPLIFIER
ANNUN ANNUNCIATOR
APPROX APPROXIMATELY
AQ-STAT AQUASTAT
ARCH ARCHITECT, ARCHITECTURAL
AS AMP SWITCH
AT AMP TRIP
ATS AUTOMATIC TRANSFER SWITCH
AUTO AUTOMATIC
AUX AUXILIARY
AV AUDIO VISUAL
AWG AMERICAN WIRE GAUGE
BATT BATTERY
BD BOARD
BLDG BUILDING
BMS BUILDING MANAGEMENT SYSTEM
C CONDUIT
CAB CABINET
CAT CATALOG
CATV CABLE TELEVISION
CB CIRCUIT BREAKER
CCTV CLOSED CIRCUIT TELEVISION
CKT CIRCUIT
CLG CEILING
COMB COMBINATION
CMPR COMPRESSOR
CONN CONNECTION
CONST CONSTRUCTION
CONT CONTINUATION OR
CONTINUOUS
CONTR CONTRACTOR
CONV CONVECTOR
CP CIRCULATING PUMP
CRT CATHODE-RAY TUBE
CT CURRENT TRANSFORMER
CTR CENTER
CU COPPER
DCP DOMESTIC WATER CIRCULATING
PUMP
DEPT DEPARTMENT
DET DETAIL
DIA DIAMETER
DISC DISCONNECT
DIST DISTRIBUTION
DN DOWN
DPR DAMPER
DS SAFETY DISCONNECT SWITCH
DT DOUBLE THROW
DWG DRAWING
EC ELECTRICAL CONTRACTOR
ELEC ELECTRIC, ELECTRICAL
ELEV ELEVATOR
ELU EMERGENCY LIGHTING UNIT
EM EMERGENCY
EMS ENERGY MANAGEMENT SYSTEM
EMT ELECTRICAL METALLIC TUBING
EP ELECTRIC PNEUMATIC
EQUIP EQUIPMENT
EWC ELECTRIC WATER COOLER
EXIST EXISTING
EXH EXHAUST
EXP EXPLOSION PROOF
FA FIRE ALARM
FABP FIRE ALARM BOOSTER POWER
SUPPLY PANEL
FACP FIRE ALARM CONTROL PANEL
FCU FAN COIL UNIT
FIXT FIXTURE
FLR FLOOR
FLUOR FLUORESCENT
FU FUSE
FUDS FUSED SAFETY DISCONNECT
SWITCH
1d
CEILING SMOKE DETECTOR
XX-1
XX-1
XX-1 XX-1
MOTOR
H
H
I
I
6 6
7 7 8a 8a
9 9
Jb
Jb
8 8
VASC. LAB
A347
GENERAL PROJECT NOTES
1 ELECTRICAL WORK SHALL BE PERFORMED UNDER THE SUPERVISION OF A
LICENSED MASTER ELECTRICIAN. PROCURE PERMITS AND LICENSES AND PAY FEES
ASSOCIATED WITH THIS WORK.
2 PERFORM WORK TO COMPLY WITH THE STANDARD PRACTICES FOR GOOD
WORKMANSHIP PUBLISHED BY NATIONAL ELECTRICAL CONTRACTORS
ASSOCIATION (NECA). COMPLY WITH THE LATEST ENFORCED EDITION OF THE
NATIONAL ELECTRICAL CODE (NEC), LOCAL CODES, AMENDMENTS, AND
ORDINANCES.
3 MATERIALS FURNISHED FOR THIS PROJECT SHALL BE NEW, COMMERCIAL GRADE,
FREE OF DEFECTS, AND LISTED BY A NATIONALLY RECOGNIZED TESTING
LABORATORY UNO.
4 LEAVE THE SITE CLEAN AND READY FOR OCCUPANCY. REMOVE DIRT, DEBRIS,
EMPTY CARTONS, TOOLS, CONDUIT AND WIRE SCRAPS AND MISCELLANEOUS
SPARE EQUIPMENT AND MATERIALS USED IN THIS DIVISION OF THE WORK DURING
CONSTRUCTION. COMPONENTS SHALL BE FREE OF DUST, GRIT AND FOREIGN
MATERIALS AND LEFT AS NEW BEFORE FINAL ACCEPTANCE OF WORK.
5 THE SYMBOLS AND ABBREVIATIONS SHOWN ON THIS SHEET MAY OR MAY NOT BE
USED IN THIS SET OF DRAWINGS.
6 CONTRACTOR SHALL BE RESPONSIBLE FOR WIRING ELECTRICAL ITEMS SHOWN
ON DRAWINGS.
7 PROVIDE CABLE OR CONDUIT AND WIRE AS REQUIRED TO ACHIEVE CIRCUITING
SHOWN. SIZE CONDUCTORS PER NEC AMPACITY AND WIRE FILL CRITERIA.
PROVIDE DEDICATED NEUTRAL AND GROUND CONDUCTORS FOR CIRCUITING,
UNLESS NOTED OTHERWISE. INCREASE BRANCH CIRCUIT AND/OR FEEDER
CONDUCTORS INCLUDING EQUIPMENT GROUNDING CONDUCTORS
PROPORTIONALLY FOR NO MORE THAN 3% VOLTAGE DROP ON BRANCH
CIRCUITS AND 2% ON FEEDERS PER ENERGY CODE.
8 COORDINATE LOCATIONS OF DEVICES WITH ARCHITECTURAL ELEVATIONS AND
DETAILS. ARCHITECTURAL ELEVATIONS AND DETAILS TAKE PRECEDENCE OVER
LOCATIONS SHOWN ON ELECTRICAL DRAWINGS.
9 COORDINATE WITH OTHER TRADES FOR PROPER INSTALLATION OF ELECTRICAL
COMPONENTS. CONSULT THE DRAWINGS OF OTHER TRADES OR CRAFTS TO
AVOID CONFLICTS WITH EQUIPMENT, ETC. CONFLICTS SHALL BE RESOLVED PRIOR
TO ROUGH-IN AND AT NO ADDITIONAL COST TO THE OWNER.
10 COORDINATE INSTALLATION OF ELECTRICAL SYSTEMS AND THOSE REQUIRING
ELECTRICAL CONNECTIONS TO MAINTAIN NEC REQUIRED CLEARANCES,
INCLUDED BY NOT LIMITED TO AREAS ABOVE ACCESSIBLE CEILINGS.
VA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
STAMP
CONSULTANT
321 4 5 6 7 8 9 10
REPLACE DAMAGED
FLOORING
5/11/2023
ELECTRICAL GENERAL INFO &
SYMBOL LEGEND, AND THIRD
FLOOR DEMOLITION PLAN
E001
SMBC
539-23-202
CINCINNATI MEDICAL CENTER
VA Station No:
BID DOCUMENTS
GENERAL ELECTRICAL REMODEL NOTES
1 BRANCH CIRCUITING INDICATED ON PLANS AND SCHEDULES IS BASED UPON
EXISTING PLANS AND SITE OBSERVATION, CONTRACTOR SHALL FIELD VERIFY THE
EXISTING CONDITIONS.
2 PROVIDE TYPED CIRCUIT BOARD DIRECTORIES TO REFLECT AS-CONSTRUCTED
CONDITIONS. FIELD VERIFY DURING CONSTRUCTION AND REVISE
ACCORDINGLY.
3 PROVIDE NECESSARY DEMOLITION TO FACILITATE NEW CONSTRUCTION WORK
ASSOCIATED WITH THIS PROJECT. COORDINATE OUTAGES WITH OWNER
MINIMUM 72 HOURS IN ADVANCE. THE OWNER RETAINS THE FIRST RIGHT OF
REFUSAL FOR SALVAGE OF DEMOLISHED MATERIALS. PROVIDE DISPOSAL OF
REMOVED MATERIAL. MAINTAIN CIRCUIT CONTINUITY AS REQUIRED.
4 IT IS THE INTENT OF THESE DIAGRAMMATIC DRAWINGS TO PROVIDE THE PROJECT
SCOPE INCLUDING, BUT NOT LIMITED TO PHASED DEMOLITION AND NEW
CONSTRUCTION. EXISTING INFORMATION INDICATED ON THESE PLANS DOES NOT
REPRESENT ALL EXISTING CONDITIONS. THIS CONTRACTOR SHALL BECOME
FAMILIAR WITH EXISTING CONDITIONS, SCOPE OF PHASING, AND PROJECT
INTENT PRIOR TO BID SUBMISSION. NO EXTRA WILL BE ALLOWED DUE TO THE LACK
OF KNOWLEDGE OF EXISTING CONDITIONS TO…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .