Attachment 1 - Plans.pdf
PDF 7 MB Posted
- Solicitation number
- SP470326B0001
- Issued by
-
Defense Logistics Agency
About this file
This is a solicitation package for structural and electrical design work related to a Building 46 Generator Tie-In project at the Defense Supply Center Richmond (DSCR) in Norfolk, Virginia. The solicitation number is FA8903-24-F-0083, with an associated contract number FA8903-21-D-0007, issued on December 15, 2025.
The project involves structural demolition and new construction work, including removal of existing concrete equipment pads and floor slabs, construction of equipment pad extensions, placement of infill slabs for new below-slab piping, and installation of structural reinforcement. Structural design criteria include concrete with f'c of 4,500 PSI and fy of 60,000 PSI, wind speeds of 113 MPH basic (88 MPH allowable stress), seismic design category B, and snow loads of 35 PSF ground load. The work also requires electrical modifications involving automatic transfer switches (ATS), generator connections, busway installation, and panel modifications to tie existing generators into Building 46's electrical system. Special inspections are mandatory per IBC Chapter 17, covering reinforcement placement, concrete strength verification, anchor installation, and formwork inspection. Delegated design submittals are required for miscellaneous metal fabrications, metal railings, and post-installed concrete and masonry anchors, all of which must be stamped by registered professional engineers and submitted for government approval prior to fabrication and installation.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
SOLICITATION NO.:
CONTRACT NO.:
ISSUE DATE:
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
T e xa s P
.E
F ir m
R e g is tr a ti o n N o
F -7
C
U s e rs
\B R
IJ
O
H N
S O
N \D o c u m e n ts
\R e v it \L o c a l F ile s \1
D
S C
R E
B
L D
G B
B ri a n .J o h n s o n W
J T
S .r v t
/1 /2
:1
:3
P M
G-001
BLDG 46
C O
V E
R S
H E
E T
D E
F E
N S
E S
U P
P L Y
C E
N T
E R
R
IC
H M
O N
D
D S
C R
N O
R F
O L K
V
IR
G
IN
IA
H D
R E
N G
IN
E
E R
IN
G
I N
C
N
W L
P
S
U
IT
E
S A
N A
N T
O N
IO
T
X
J G
A R
A F
O L A
J G
A R
A F
O L A
J G
A R
A F
O L A
D E
C E
M B
E R
F A
-2
-F
-0
F A
-2
-D
-0
B U
IL
D
IN
G
G
E N
E R
A T
O R
T
IE
-I N
NORFOLK, VIRGINIA
FA8903-24-F-0083
FA8903-21-D-0007
DECEMBER 15, 2025
DEFENSE SUPPLY CENTER RICHMOND (DSCR)
BUILDING 46 GENERATOR TIE-IN
BLDG 46
RTA
VICINITY MAP
INSTALLATION / HAUL MAP
AREA OF WORK
HAUL ROUTE
SHEET LIST
SHEET NUMBER SHEET NAME 6
R T
A
GENERAL
G-001 COVER SHEET ● ● ●
STRUCTURAL
S-001 GENERAL STRUCTURAL NOTES ● ●
SD101 FIRST FLOOR DEMOLITION PLAN ●
S-002 STRUCTURAL SPECIAL INSPECTIONS ● ●
S-003 TYPICAL CONCRETE DETAILS 1 ● ●
S-100 FIRST FLOOR FRAMING PLAN ●
ELECTRICAL
E-001 ELECTRICAL SYMBOLS AND GENERAL NOTES ● ● ●
ES101 OVERALL SITE PLAN ● ● ●
ES102 ENLARGED SITE PLAN ● ● ●
E-110 POWER PLANS ● ● ●
E-601 DEMOLITION ONE-LINE DIAGRAM ● ● ●
E-602 NEW ONE-LINE DIAGRAM ● ● ●
PLAN NORTH
12/15/2025
GENERAL
G1. SCOPE
THE NOTES ON THIS SHEET AND THE STANDARD STRUCTURAL DETAILS ARE GENERAL AND
APPLY TO THE ENTIRE PROJECT WHETHER SPECIFICALLY CALLED OUT OR NOT, EXCEPT
WHERE THERE ARE SPECIFIC INDICATIONS TO THE CONTRARY ON STRUCTURAL SHEETS. IF
THERE ARE QUESTIONS, THEY SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER AND
ANSWERED IN WRITING PRIOR TO CONSTRUCTION.
G2. APPLICABLE SPECIFICATIONS AND CODES
A. UFC 1-200-01 (WITH CHANGE 4, DATED 17 DECEMBER 2024)
B. UFC 3-301-01 (WITH CHANGE 3, DATED 3 FEBRUARY 2025)
C. INTERNATIONAL BUILDING CODE, IBC 2024 WITH APPLICABLE EDITIONS OF THE CODE
REFERENCED STANDARDS.
D. ASCE 7-22
E. ACI 318-19
G3. DESIGN CRITERIA
1. APPLIES TO ALL STRUCTURES (UNO)
A. DEAD LOAD:
1. ACTUAL TRIBUTARY STRUCTURE WEIGHT
2. SELF-WEIGHT OF EATON NEMA TYPE-1 TRANSFER SWITCH: 4,700 LBS
B. LIVE LOAD:
1. WALKWAYS: 100 PSF
C. WIND:
1. RISK CATEGORY: II
2. BASIC WIND SPEED (VULT): 113 MPH
3. ALLOWABLE STRESS WIND SPEED (VASD): 88 MPH
4. TORNADO SPEED (VT): NOT APPLICABLE PER ASCE 7
FIGURE 32.1-1
5. EXPOSURE: C
6. INTERNAL PRESSURE COEFFICIENT: ±0.18
7. DESIGN WIND PRESSURE: 31 PSF
D. SEISMIC:
1. RISK CATEGORY: II
2. IMPORTANCE FACTOR: 1.0
3. SPECTRAL RESPONSE ACCELERATION, (SS) = 0.23g
4. SPECTRAL RESPONSE ACCELERATION, (S1) = 0.052g
5. SITE CLASS: D (ASSUMED)
6. SEISMIC DESIGN CATEGORY: B
7. SPECTRAL RESPONSE ACCELERATION, (SDS) = 0.18g
8. SPECTRAL RESPONSE ACCELERATION, (SD1) = 0.073g
9. BASIC SEISMIC FORCE RESISTING SYSTEM: ASCE 7 CHAPTER 13 - SEISMIC DESIGN
REQUIREMENTS FOR NONSTRUCTURAL
COMPONENTS
10. ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE PROCEDURE
11. DESIGN BASE SHEAR: Cs*EQUIPMENT WEIGHT
12. SEISMIC RESPONSE COEFFICIENT, (CS) = 0.054
13. COMPONENT STRENGTH FACTOR, (Rpo) = 1.5
E. SNOW LOAD:
1. GROUND SNOW LOAD (Pg) = 35 PSF
2. FROST DEPTH = 18 IN
3. EXPOSURE FACTOR = 0.90
4. THERMAL FACTOR = 1.03
5. FLAT ROOF SNOW LOAD = 30 PSF
F. FLOOD CRITERIA: NOT APPLICABLE
G. ICE LOADS:
1. ICE THICKNESS: 0.52 IN
2. ICE THICKNESS FACTOR: 0.997
3. DESIGN ICE THICKNESS: 0.518 IN
4. DESIGN ICE WEIGHT: 2.5 PSF
H. ROOF RAIN LOAD:
1. 15-MINUTE PRECIPITATION INTENSITY: 6.09 IN/HR
2. 60-MINUTE PRECIPITATION INTENSITY: 3.21 IN/HR
G4. AT THE TIME OF THIS DESIGN, NO GEOTECHNICAL REPORT WAS PREPARED FOR THIS PROJECT.
THE FOLLOWING ASSUMED VALVE WAS USED DURING DESIGN BASED ON THE AS-BUILT DRAWINGS OF ADJACENT STRUCTURES AND IBC TABLE 1806.2. CONTRACTOR SHALL VERIFY SOIL CONDITIONS
PRIOR TO CONSTRUCTION AND PLACEMENT OF SOIL SUPPORTED CONCRETE.
ALLOWABLE SOIL BEARING PRESSURE = 1,500 PSF (GRAVITY)
2,000 PSF (SEISMIC/WIND)
LATERAL BEARING PRESSURE = 100 PSF
COHESION = 130 PSF
G5. SAFETY
SAFETY AND STRUCTURE STABILITY DURING CONSTRUCTION ARE THE SOLE RESPONSIBILITY
OF THE CONTRACTOR. STRUCTURES HAVE BEEN DESIGNED TO RESIST THE DESIGN LIVE
LOADS ONLY AS A COMPLETED STRUCTURE.
G6. OPENINGS
OPENINGS FOR PIPES, DUCTS, CONDUITS, ETC. ARE NOT ALL SHOWN ON THE
STRUCTURAL DRAWINGS. COORDINATE AND PROVIDE OPENINGS AS REQUIRED TO
ACCOMMODATE ALL WORK SHOWN OR SPECIFIED IN THE CONTRACT DOCUMENTS AND
OTHERWISE REQUIRED FOR THE FURNISHING OF A FUNCTIONALLY COMPLETE PROJECT.
REINFORCE AROUND OPENINGS PER STANDARD STRUCTURAL DETAILS UNLESS OTHERWISE
SHOWN.
G7. SPECIAL INSPECTIONS
SPECIAL INSPECTIONS ARE REQUIRED IN ACCORDANCE WITH CHAPTER 1 AND CHAPTER 17
OF THE IBC. PAYMENT FOR THESE INSPECTIONS IS NOT THE RESPONSIBILITY OF
THE CONTRACTOR. THE CONTRACTOR SHALL PROVIDE FOR FULL ACCESS TO THE WORK
BY THE SPECIAL INSPECTOR AND SHALL PROVIDE FOR THESE INSPECTIONS IN THEIR
CONSTRUCTION SCHEDULE IN ACCORDANCE WITH THE SPECIFICATIONS.
G8. STANDARD DETAILS
THE STANDARD DETAILS DEPICT TYPICAL DETAILING TO BE USED ON THIS PROJECT. IF
CONDITIONS ARE NOT EXPLICITLY SHOWN ON THE DRAWINGS THEY SHALL BE MADE
SIMILAR TO THE STANDARD DETAILS. OBTAIN APPROVAL OF ENGINEER IN WRITING FOR
SIMILAR CONDITIONS PRIOR TO CONSTRUCTION.
G9. THE CONTACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND ELEVATIONS OF EXISTING
CONSTRUCTION AS REQUIRED TO COORDINATE NEW CONSTRUCTION. SUBMIT REQUIRED
CHANGES FOR APPROVAL.
G10. CONTRACTOR TO SUBMIT FOR REVIEW ALL EQUIPMENT SIZES, OPERATING WEIGHTS,
VIBRATION FORCES, SUPPORT LOCATIONS, ALONG WITH ANY FLOOR OPENINGS, NOTCHES,
AND RECESSES REQUIRED BY SUCH EQUIPMENT. CONCRETE SUPPORT PADS AND/OR
FRAMING REQUIRED TO SUPPORT SAID EQUIPMENT SHALL NOT BE FABRICATED AND
PLACED UNTIL THE CONCRETE SUPPORT PADS AND/OR FRAMING IS APPROVED TO
SUPPORT THE EQUIPMENT.
CONCRETE
C1. DESIGN STRENGTHS:
F'c = 4,500 PSI Fy = 60,000 PSI
C2. CONCRETE COVER
UNLESS OTHERWISE NOTED, PROVIDE CONCRETE COVER FOR REINFORCING AS FOLLOWS:
CONCRETE DEPOSITED AGAINST EARTH: 3"
TIE REINFORCING AT COLS & PILASTERS: 1½"
ALL OTHER: 2"
SEE DRAWINGS FOR EXCEPTIONS
C3. SEE SPECIFICATIONS FOR REINFORCING PLACEMENT REQUIREMENTS.
C4. REFER TO OTHER DISCIPLINE DRAWINGS PRIOR TO CONSTRUCTION FOR EMBEDDED ITEMS
AND PENETRATIONS NOT SHOWN ON STRUCTURAL DRAWINGS. AS REQUIRED TO
ACCOMMODATE ALL WORK SHOWN OR SPECIFIED IN THE CONTRACT DOCUMENTS AND
OTHERWISE REQUIRED FOR THE FURNISHING OF A FUNCTIONALLY COMPLETE PROJECT.
REINFORCE AROUND OPENINGS PER STANDARD STRUCTURAL DETAILS UNLESS OTHERWISE
SHOWN.
C5. PROVIDE 3/4" CHAMFERS AT ALL EXPOSED EDGES. NOT ALL CHAMFERS MAY BE SHOWN ON DRAWINGS.
C6. FIELD ADJUST REINFORCING AT OPENINGS AND EMBEDDED ITEMS AS INDICATED.
C7. ANCHOR BOLTS NOT SPECIFIED BY ENGINEER SHALL BE DESIGNED AND CERTIFIED BY A
REGISTERED PROFESSIONAL ENGINEER, RETAINED BY THE CONTRACTOR, IN ACCORDANCE
WITH APPLICABLE PROJECT AND CODE REQUIREMENTS. SUBMIT AS A SHOP DRAWING FOR
REVIEW AND APPROVAL BY THE ENGINEER. COORDINATE LOCATION, SIZE AND EMBEDMENT
PRIOR TO CASTING CONCRETE.
C8. ABSOLUTELY NO WELDING OF REINFORCING BARS OR TORCHING TO BEND REINFORCING
BARS SHALL BE ALLOWED.
C9. CONTRACTOR SHALL SUBMIT A CONCRETE PLACEMENT PLAN IDENTIFYING JOINT TYPES, JOINT
LOCATIONS AND CONCRETE PLACEMENT SEQUENCE.
C10. ALL CAST IN PLACE AND POST-INSTALLED ANCHORS INDICATED IN THE STRUCTURAL
DOCUMENTS SHALL COMPLY WITH CHAPTER 17 OF ACI 318 AND CHAPTER 19 OF THE
IBC. ALL EXPANSION AND ADHESIVE ANCHORS SHALL HAVE THE ICC REPORT SHOWING
EQUIVALENT LOAD CAPACITY. SUBMIT AND INSTALL PER THE ICC EVALUATION REPORT.
CONSTRUCTION AT EXISTING STRUCTURES
CE1. WHERE DRILL AND EPOXY REINFORCING OR ANCHORS ARE INSTALLED, CONTRACTOR
SHALL NOT DAMAGE EXISTING REINFORCING. IF REQUIRED CONTRACTOR SHALL HAVE
EXISTING CONCRETE INVESTIGATED USING GROUND PENETRATING RADAR TO LOCATE
EXISTING REINFORCING.
CE2. EXISTING CONCRETE SURFACES TO BE JOINED WITH NEW CONCRETE SHALL BE
ROUGHENED TO A 1/4" AMPLITUDE, THOROUGHLY CLEANED BY SAND BLASTING, AND
APPLY BONDING AGENT JUST PRIOR TO PLACEMENT OF NEW CONCRETE.
CE3. WHERE EXISTING REINFORCING IS TO BE PRESERVED, CONTRACTOR SHALL STRAIGHTEN
AND SAND BLAST REINFORCING JUST PRIOR TO PLACEMENT OF NEW CONCRETE.
DELEGATED DESIGN SUBMITTALS
D1. DEFINITION:
DELEGATED DESIGN SUBMITTALS ARE ITEMS FOR WHICH THE FINAL DESIGN OF A SPECIFIC
ELEMENT OF THE PERMANENT CONSTRUCTION WORK EXPRESSLY DELEGATED TO A PROPERLY
LICENSED AND REGISTERED DESIGN PROFESSIONAL ENGINEER RETAINED OR EMPLOYED BY THE
CONTRACTOR, SUBCONTRACTOR, SUPPLIER OF ANY TIER. "DELEGATED DESIGN" APPLIES ONLY
TO PERMANENT WORK THAT WILL BE PART OF THE COMPLETED PROJECT AS A FUNCTIONING WHOLE.
D2. DELEGATED DESIGN LIST:
THE FOLLOWING IS A LIST OF DELEGATED DESIGN SUBMITTALS THAT ARE EXPECTED TO CONTAIN
STAMPED STRUCTURAL CALCULATIONS OF SAFETY-RELATED SYSTEM INFORMATION FOR REVIEW.
THESE SUBMITTALS APPLY TO DELEGATED DESIGNED SYSTEMS PRIOR TO INSTALLATION OF THE
INDICATED STRUCTURAL ELEMENT, EQUIPMENT, DISTRIBUTION SYSTEM, COMPONENT, OR ITS
ANCHORAGE. THE CONTRACTOR SHALL SUBMIT THE REQUIRED ENGINEER CERTIFICATION,
SUPPORTING DATA, AND STAMPED DRAWINGS FOR REVIEW AND ACCEPTANCE BY THE CONTRACTING
OFFICER.
DEFERRED SUBMITTALS
ITEMSPEC SECTIONS
05 50 13 MISCELLANEOUS METAL FABRICATIONS
05 52 00 METAL RAILINGS
VARIOUS
ANY EQUIPMENT OR COMPONENT IN WHICH A
TECHNICAL SPECIFICATION REQUIRES SUBMITTAL
OF EQUIPMENT OR ANCHORAGE SYSTEM
CALCULATIONS
05 05 20 POST-INSTALLED CONCRETE AND MASONRY
ANCHORS
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
T e xa s P
.E
F ir m
R e g is tr a ti o n N o
F -7
C rv t\ \1
D
S C
R S
B
L D
G B c o lin
.m u ld e ri c k Z
G A
.r v t
/1 /2
:5
:1
A
M
S-001
BLDG 46
G E
N E
R A
L S
T R
U C
T U
R A
L N
O T
E S
D E
F E
N S
E S
U P
P L Y
C E
N T
E R
R
IC
H M
O N
D
D S
C R
N O
R F
O L K
V
IR
G
IN
IA
H D
R E
N G
IN
E
E R
IN
G
I N
C
N
W L
P
S
U
IT
E
S A
N A
N T
O N
IO
T
X
C M
U L D
E R
IC
K
C M
U L D
E R
IC
K
K T
E E
M S
M A
D E
C E
M B
E R
F A
-2
-F
-0
F A
-2
-D
-0
R T
A
B U
IL
D
IN
G
G
E N
E R
A T
O R
T
IE
-I N
STATEMENT OF SPECIAL INSPECTIONS (IBC 1705):
UNLESS NOTED OTHERWISE
SI1. SHOP FABRICATED ITEMS BY APPROVED FABRICATOR IS EXEMPT FROM SPECIAL INSPECTION. UPON COMPLETION, APPROVED FABRICATOR SHALL SUBMIT A CERTIFICATE OF COMPLIANCE STATING WORK WAS PERFORMED IN ACCORDANCE WITH APPROVED
CONSTRUCTION DOCUMENTS.
SI2. CONTRACTOR SHALL SUBMIT A WRITTEN STATEMENT OF RESPONSIBILITY PRIOR TO CONSTRUCTION, INCLUDING:
A. ACKNOWLEDGEMENT OF SPECIAL INSPECTION REQUIREMENTS.
B. ACKNOWLEDGE THAT CONTROL WILL BE EXERCISED TO CONFORM WITH APPROVED CONSTRUCTION DOCUMENTS.
C. PROCEDURES FOR EXERCISING CONTROL, INCLUDING METHOD AND FREQUENCY OF REPORTING, AND DISTRIBUTION OF
REPORTS.
D. IDENTIFICATION AND QUALIFICATION OF PERSON(S) EXERCISING SUCH CONTROL.
SI3. THE FOLLOWING CONSTRUCTION IS SUBJECT TO SPECIAL INSPECTION:
SCHEDULE OF SPECIAL INSPECTION SERVICES
FREQUENCY
CONTINUOUS PERIODIC
CODE
REFERENCE REMARKSINSPECTION ITEM REQUIRED
GENERAL STRUCTURAL OBSERVATIONS
CONDUCT DAILY VISUAL OBSERVATION OF THE
STRUCTURAL SYSTEMS FOR GENERAL
CONFORMANCE TO THE CONSTRUCTION
DOCUMENTS. PREPARE WEEKLY REPORT OF
OBSERVATIONS DESCRIBING WORK PROGRESS
AND NON-CONFORMING ITEMS.
SOIL AND EARTHWORK
VERIFY MATERIALS BELOW SHALLOW
FOUNDATIONS ARE ADEQUATE TO ACHIEVE
THE DESIGN BEARING CAPACITY.
- X
VERIFY EXCAVATIONS ARE EXTENDED TO PROPER
DEPTH AND HAVE REACHED PROPER MATERIAL.
PERFORM CLASSIFICATION AND TESTING OF
COMPACTED FILL MATERIALS.
DURING FILL PLACEMENT, VERIFY USE OF PROPER
MATERIALS AND PROCEDURES OF THE APPROVED
GEOTECHNICAL REPORT. VERIFY DENSITIES AND
LIFT THICKNESSES DURING PLACEMENT AND
COMPACTION OF COMPACTED FILL.
PRIOR TO PLACEMENT OF COMPACTED FILL,
INSPECT SUBGRADE AND VERIFY THAT SITE
HAS BEEN PREPARED PROPERLY.
- X
- X
- X
X -
- X
CONCRETE AND REINFORCING STEEL
INSPECT REINFORCEMENT AND VERIFY
PLACEMENT.
- X
TABLE 1705.6
ACI 318: CH 20, 25.2,
25.3, 26.6.1-26.6.3
TABLE 1705.3
INSPECT ANCHORS CAST IN CONCRETE. - X ACI 318: 26.13.3.3
INSPECT ANCHORS POST INSTALLED IN HARDENED
CONCRETE MEMBERS.
A. ADHESIVE ANCHORS INSTALLED IN
HORIZONTALLY OR UPWARDLY INCLINED
ORIENTATIONS TO RESIST SUSTAINED
TENSION LOADS
B. MECHANICAL ANCHORS AND ADHESIVE
ANCHORS NOT DEFINED ABOVE.
X - ACI 318: 26.13.3.2
- X ACI 318: 26.13.3
VERIFY USE OF REQUIRED DESIGN MIX. - X
ACI 318: CH. 19,
26.4.3, 26.4.4
PRIOR TO CONCRETE PLACEMENT, FABRICATE
SPECIMENS FOR STRENGTH TESTS, PERFORM
SLUMP AND AIR CONTENT TESTS, AND
DETERMINE THE TEMPERATURE OF THE
CONCRETE.
X -
ASTM C31
ASTM C172
ACT 318: 26.5, 26.12
INSPECT CONCRETE PLACEMENT FOR PROPER
APPLICATION TECHNIQUES.
ACI 318: 26.5X -
VERIFY MAINTENANCE OF SPECIFIED CURING
TEMPERATURE AND TECHNIQUES.
ACI 318: 26.5.3-26.5.5- X
VERIFY IN-SITU CONCRETE STRENGTH. ACI 318: 26.11.2- X
INSPECT FORMWORK SHAPE, LOCATION AND
DIMENSIONS OF THE CONCRETE MEMBER BEING
FORMED.
ACI 318: 26.11.1.2(b)- X
IBC 1904.1, 1904.2
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
T e xa s P
.E
F ir m
R e g is tr a ti o n N o
F -7
C rv t\ \1
D
S C
R S
B
L D
G B c o lin
.m u ld e ri c k Z
G A
.r v t
/1 /2
:5
:1
A
M
S-002
BLDG 46
S T
R U
C T
U R
A L S
P E
C
IA
L I
N S
P E
C T
IO
N
S
D E
F E
N S
E S
U P
P L Y
C E
N T
E R
R
IC
H M
O N
D
D S
C R
N O
R F
O L K
V
IR
G
IN
IA
H D
R E
N G
IN
E
E R
IN
G
I N
C
N
W L
P
S
U
IT
E
S A
N A
N T
O N
IO
T
X
C M
U L D
E R
IC
K
C M
U L D
E R
IC
K
K T
E E
M S
M A
D E
C E
M B
E R
F A
-2
-F
-0
F A
-2
-D
-0
R T
A
B U
IL
D
IN
G
G
E N
E R
A T
O R
T
IE
-I N
4" MIN
NOTES:
1. PROVIDE ABOVE PAD UNDER ALL ELECTRICAL EQUIPMENT SUPPORTED ON STRUCTURAL SLABS.
2. PAD THICKNESS SHALL BE A MINIMUM OF 4". CONTRACTOR SHALL VERIFY THE PAD DIMENSIONS.
3. PROVIDE EMBEDDED CHANNELS FOR ANCHORING ELECTRICAL EQUIPMENT WHERE REQUIRED.
4. BEFORE EQUIPMENT SUPPORT PADS ARE CAST, THE PAD SIZES AND REINFORCING SHALL BE
APPROVED BY THE ENGINEER AS BEING CAPABLE OF SUPPORTING EQUIPMENT TO BE PLACED
THEREON. EQUIPMENT BASE DIMENSIONS SHALL BE THE LARGER OF AS DETERMINED BY THE
EQUIPMENT MANUFACTURER OR AS INDICATED ON THE DRAWINGS. SUBMIT ALL EQUIPMENT
DIMENSIONS AND LOADS TO ENGINEER.
5. 6" MINIMUM PAD EDGE DIMENSION TO EQUIPMENT ANCHOR BOLT APPLIES FOR ALL NON-ELECTRICAL EQUIPMENT SUPPORT PADS. AT ELECTRICAL EQUIPMENT, PROVIDE 1" FROM EDGE OF EQUIPMENT
TO EDGE OF PAD.
6. THE SIZE, NUMBER, TYPE, LOCATION AND THREAD PROJECTION OF THE ANCHOR BOLTS SHALL BE AS DETERMINED BY THE EQUIPMENT MANUFACTURER AND SHALL BE AS APPROVED BY THE ENGINEER.
ANCHOR BOLTS SHALL BE HELD IN POSITION WITH A TEMPLATE WHILE EQUIPMENT BASE IS BEING
CAST.
7. EQUIPMENT BASES SHALL BE INSTALLED LEVEL UNLESS SPECIFIED OTHERWISE, TOLERANCE IS 1/8"
ACROSS PLAN DIAGONALS.
ADDL #3
CLOSED TIES
CONT AT
PERIMETER
4" MIN
8" MAX
EXISTING CONCRETE
SLAB
#3@12 TYP, SET INTO EXIST
CONCRETE W/ EPOXY
ANCHOR SYSTEM (3 1/2"
EMBED)
1 1/2"
CLR
CONCRETE SURFACE SHALL BE
CLEAN, FREE OF LAITANCE,
ROUGHENED TO A 1/4" AMPLITUDE,
AND COATED WITH BONDING AGENT
#3@12 EW EQUIPMENT ANCHOR BOLT
EQUIPMENT BASE PLATE
8" LEG
3/4" CHAMFER TYP
/4
6" MIN
6" MIN
SEE PAD
NOTE 3
1/4"
/8
V E
R
IF
Y
F
IE
L D
NEW ELECTRICAL CONDUIT.
SEE ELECTRICAL DRAWINGS
FOR REQUIREMENTS
EXIST REINF
SAWCUT JOINT, TYP
ROUGHEN TO A MIN 1/4"
AMPLITUDE AND APPLY
BONDING AGENT
6" MIN, TYP
NEW #3@12" OC BOTTOM
NEW 10MIL VAPOR BARRIER
AT NEW INFILL SLAB.
OVERLAP 3" MIN WITH EXIST
VAPOR BARRIER AND TAPE
UNDISTURBED SUBGRADE
PROVIDE PIPE BEDDING IN
ACCORDANCE WITH AWWA
C600. SEE NOTE 1 BELOW FOR
ADDITIONAL INFORMATION.
DO NOT UNDERMINE
EXIST SLAB
WORK OF DEMOLITION/ NEW WORK
REFERENCE ELEC PLANS FOR EXTENTS
AND LOCATIONS AS REQ'D FOR ELEC CONDUIT
SAND LAYER BELOW CONC. SEE SAND
CLASSIFICATION IN NOTE 1 FOR
ADDITIONAL INFORMATION.
V .I
.F
B A
C K
F
IL
L
M
IN
C L R
NOTES:
1. CONDUIT BEDDING MAY INCLUDED THE FOLLOWING:
A. CLASS I: ANGULAR, 1/4" TO 1 1/2", GRADED STONE, INCLUDING A NUMBER OF FILL MATERIALS THAT HAVE REGIONAL SIGNIFICANCE SUCH AS CORAL, SLAG, CINDERS, CRUSHED STONE, AND CRUSHED SHELLS.
B. CLASS II: COARSE SANDS AND GRAVELS WITH MAXIMUM PARTICLE SIZE OF 1 1/2", INCLUDING VARIOUS GRADED
SANDS AND GRAVELS CONTAINING SMALL PERCENTAGES OF FINES, GENERALLY GRANULAR AND
NONCOHESIVE, EITHER WET OR DRY. SOIL TYPES GW, GP, SW, AND SP ARE INCLUDED IN THIS CLASS AS
SPECIFIED IN ASTM D2487.
C. SAND: CLEAN, COARSE-GRAINED SAND CLASSIFIED AS SW OR SP BY ASTM D2487 FOR BEDDING BACKFILL.
D. GRAVEL AND CRUSHED STONE: CLEAN, COARSELY GRADED NATURAL GRAVEL, CRUSHED STONE OR A
COMBINATION THEREOF IDENTIFIED AS GW OR GP IN ACCORDANCE WITH ASTM D2487 AS INDICATED.
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
T e xa s P
.E
F ir m
R e g is tr a ti o n N o
F -7
C rv t\ \1
D
S C
R S
B
L D
G B c o lin
.m u ld e ri c k Z
G A
.r v t
/1 /2
:5
:1
A
M
S-003
BLDG 46
T Y
P
IC
A L C
O N
C R
E T
E D
E T
A
IL
S
D E
F E
N S
E S
U P
P L Y
C E
N T
E R
R
IC
H M
O N
D
D S
C R
N O
R F
O L K
V
IR
G
IN
IA
H D
R E
N G
IN
E
E R
IN
G
I N
C
N
W L
P
S
U
IT
E
S A
N A
N T
O N
IO
T
X
C M
U L D
E R
IC
K
C M
U L D
E R
IC
K
K T
E E
M S
M A
D E
C E
M B
E R
F A
-2
-F
-0
F A
-2
-D
-0
R T
A
B U
IL
D
IN
G
G
E N
E R
A T
O R
T
IE
-I N
NTS
H1
SHALLOW EQUIPMENT PAD
NTS
H7
SLAB INFILL FOR NEW BELOW SLAB PIPING
TT
4' - 9 3/8" (*) 5' - 4" (*)
3' - 2" (*)
B31B46
AREA OF WORK
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
T e xa s P
.E
F ir m
R e g is tr a ti o n N o
F -7
GENERAL NOTES
SHEET KEYNOTES
SHEET LEGEND
KEYPLAN
C rv t\ \1
D
S C
R S
B
L D
G B c o lin
.m u ld e ri c k Z
G A
.r v t
/1 /2
:5
:1
A
M
SD101
BLDG 46
F
IR
S T
F L O
O R
D E
M O
L
IT
IO
N
P L A
N
D E
F E
N S
E S
U P
P L Y
C E
N T
E R
R
IC
H M
O N
D
D S
C R
N O
R F
O L K
V
IR
G
IN
IA
H D
R E
N G
IN
E
E R
IN
G
I N
C
N
W L
P
S
U
IT
E
S A
N A
N T
O N
IO
T
X
C M
U L D
E R
IC
K
C M
U L D
E R
IC
K
K T
E E
M S
M A
D E
C E
M B
E R
F A
-2
-F
-0
F A
-2
-D
-0
R T
A
B U
IL
D
IN
G
G
E N
E R
A T
O R
T
IE
-I N
1/4" = 1'-0" A1
FIRST FLOOR DEMOLITION PLAN
1 EXISTING CONCRETE EQUIPMENT PAD.
2 EXISTING CONCRETE FLOOR SLAB.
3 EXISTING CONCRETE SLAB AT LOADING DOCK PLATFORM.
4 EXISTING CONCRETE EQUIPMENT PAD TO BE REMOVED. EXTENTS INDICATED
ARE PRELIMINARY ESTIMATES OF CONCRETE DEMOLITION. FINAL EXTENTS OF
DEMOLITION MUST BE DETERMINED BY CONTRACTOR BASED ON EXISTING
CONDITIONS AND CONTRACTOR'S MEANS AND METHODS.
5 EXISTING CONCRETE EQUIPMENT PAD AND SLAB-ON-GRADE TO BE REMOVED.
COORDINATE EXTENTS WITH ELECTRICAL DRAWINGS. EXTENTS INDICATED
ARE PRELIMINARY ESTIMATES OF SLAB-ON-GRADE AND CONCRETE
DEMOLITION. FINAL EXTENTS OF DEMOLITION MUST BE DETERMINED BY
CONTRACTOR BASED ON ELECTRICAL REQUIREMENTS AND CONTRACTOR'S
MEANS AND METHODS.
1. SEE STANDARD DRAWINGS FOR GENERAL STRUCTURAL NOTES AND STANDARD
DETAILS.
2. (*) INDICATES EXISTING DIMENSIONS TO BE FIELD VERIFIED BY CONTRACTOR.
3. CONTRACTOR SHALL VERIFY ALL EXISTING FRAMING MEMBER SIZES AND
SPACING INDICATED. THE CONTRACTOR SHALL NOTIFY THE CONTRACTING
OFFICER OF ANY DISCREPANCIES.
4. TOP OF EXISTING CONCRETE SLAB EL. 0'-0".
5. COORDINATE WITH ARCHITECTURAL AND ELECTRICAL DRAWINGS FOR
ADDITIONAL INFORMATION NOT SHOWN ON PLAN.
6. CONTRACTOR SHALL REVIEW AS-BUILT DRAWING DLA OPS CENTER PHASE 1,
CONTRACT NUMBER W9123613-D-0035 TO-0006 DATED 03 NOV 2014 FOR EXISTING
INFORMATION. VERIFY ALL DIMENSIONS SHOWN WITH EXISTING CONSTRUCTION
AND REPORT ANY DISCREPANCIES TO THE CONTRACTING OFFICER.
0 2' 4' 8'
PLAN NORTH
22' - 0" (*) 8' - 3" (*)
/4
/4
/4
/4
3' - 8 1/4" (*) 6' - 4" (*) 8' - 6" (*)
6"
/4
4' - 9 3/8" (*) 5' - 4" (*)
B31B46
AREA OF WORK
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
T e xa s P
.E
F ir m
R e g is tr a ti o n N o
F -7
GENERAL NOTES
SHEET KEYNOTES
SHEET LEGEND
KEYPLAN
C rv t\ \1
D
S C
R S
B
L D
G B c o lin
.m u ld e ri c k Z
G A
.r v t
/1 /2
:5
:1
A
M
S-100
BLDG 46
F
IR
S T
F L O
O R
F R
A M
IN
G
P L A
N
D E
F E
N S
E S
U P
P L Y
C E
N T
E R
R
IC
H M
O N
D
D S
C R
N O
R F
O L K
V
IR
G
IN
IA
H D
R E
N G
IN
E
E R
IN
G
I N
C
N
W L
P
S
U
IT
E
S A
N A
N T
O N
IO
T
X
C M
U L D
E R
IC
K
C M
U L D
E R
IC
K
K T
E E
M S
M A
D E
C E
M B
E R
F A
-2
-F
-0
F A
-2
-D
-0
R T
A
B U
IL
D
IN
G
G
E N
E R
A T
O R
T
IE
-I N
1/4" = 1'-0" A1
FIRST FLOOR FRAMING PLAN - NEW WORK
1 EXISTING CONCRETE FLOOR SLAB.
2 EXISTING CONCRETE EQUIPMENT PAD.
3 EXISTING CONCRETE SLAB AT LOADING DOCK PLATFORM.
4 EQUIPMENT PAD EXTENSION. ROUGHEN EXISTING SURFACES OF EXISTING
CONCRETE TO 1/4" AMPLITUDE PRIOR TO PLACING NEW CONCRETE.
REINFORCING PER DETAIL H1 ON SHEET S-003.
5 #3x2'-10" @12" O.C. SET INTO EXISTING CONCRETE WITH EPOXY ADHESIVE
SYSTEM, 13" EMBED. PLACE BARS MID-DEPTH.
6 INFILL SLAB PER DETAIL H7 ON SHEET S-003.
1. SEE STANDARD DRAWINGS FOR GENERAL STRUCTURAL NOTES AND STANDARD
DETAILS.
2. (*) INDICATES EXISTING DIMENSIONS TO BE FIELD VERIFIED BY CONTRACTOR.
3. CONTRACTOR SHALL VERIFY ALL EXISTING FRAMING MEMBER SIZES AND
SPACING INDICATED. THE CONTRACTOR SHALL NOTIFY THE CONTRACTING
OFFICER OF ANY DISCREPANCIES.
4. TOP OF EXISTING CONCRETE SLAB EL. 0'-0".
5. COORDINATE WITH ARCHITECTURAL AND ELECTRICAL DRAWINGS FOR
ADDITIONAL INFORMATION NOT SHOWN ON PLAN.
6. CONTRACTOR SHALL REVIEW AS-BUILT DRAWING DLA OPS CENTER PHASE 1,
CONTRACT NUMBER W9123613-D-0035 TO-0006 DATED 03 NOV 2014 FOR EXISTING
INFORMATION. VERIFY ALL DIMENSIONS SHOWN WITH EXISTING CONSTRUCTION
AND REPORT ANY DISCREPANCIES TO THE CONTRACTING OFFICER.
0 2' 4' 8'
PLAN NORTH
ELECTRICAL SYMBOLS
XXX
J
KVA
SPD
WH
DMP
NAME
208/120V
3 PH , 4W
ATS
G
GFS
CB
CONDUIT RUN BETWEEN EQUIPMENT.
CURRENT TRANSFORMER (CT)
VOLTAGE TRANSFORMER (VT, PT, OR CPT)
UTILITY WATT-HOUR METER PER UTILITY
REQUIREMENTS
GROUND
LIGHTNING ARRESTER
DIGITAL METERING PACKAGE
LOW VOLTAGE SURGE PROTECTIVE DEVICE
CONTROL PANEL WITH DISCONNECT SWITCH
INTEGRAL OR PROVIDED WITH ASSOCIATED
EQUIPMENT
TWO RECEPTACLES IN 2-GANG BOX UNDER
COMMON COVER PLATE
X
Y
PLUG-IN RECEPTACLE STRIP, QUANTITY AND
SPACING OF RECEPTACLES AS NOTED OR
SPECIFIED
SWITCHBOARD OR PANELBOARD; NAME,
VOLTAGE, PHASE, NUMBER OF WIRES WHEN
INDICATED
CONDUIT TAG OR CIRCUIT NUMBER - WIRE AND
CONDUIT SIZE AS SPECIFIED IN CIRCUIT
SCHEDULE ON THE SHEETS
CONDUIT STUBBED OUT AND CAPPED
CIRCUIT CONTINUATION
NON-MOTOR LOAD WITH DESIGN KVA, KW,
OR AMP
SIMPLEX RECEPTACLE
X
Y
NON-FUSED SWITCH, CURRENT RATING, AND
NUMBER OF POLES AS NOTED (3 POLE UON)
Y
X
SPECIAL-PURPOSE RECEPTACLE AS
DEFINED ON PLANS
DUPLEX RECEPTACLE
GROUND FAULT SENSOR
CONDUCTORS ROUTED IN EQUIPMENT
UNDERGROUND CONDUIT
PANELBOARD (LESS THAN 250V)
PANELBOARD (250V TO 600V)
JUNCTION OR PULL BOX
CONTROL PANEL INTEGRAL OR PROVIDED WITH
ASSOCIATED EQUIPMENT
IC INSTRUMENTATION / CONTROL DEVICE
PB PUSHBUTTON
SELECTOR SWITCHSS
3-PHASE, 4-WIRE GROUNDED WYE
CONNECTION
3-PHASE, 3-WIRE DELTA CONNECTION
TRANSFORMER
TRANSFER SWITCH, CURRENT RATING, AND
NUMBER OF POLES AS NOTED
GENERATOR
NON-FUSED SAFETY SWITCH, 30A, 3P, X
INDICATES AMP RATING GREATER THAN 30A
FUSIBLE SWITCH, CURRENT RATING, FUSE
RATING, AND QUANTITY AS NOTED (3 POLE UON)
FUSED CUTOUT, CURRENT RATING, FUSE RATING,
AND QUANTITY AS NOTED
FUSE, RATING, AND NUMBER OF FUSES AS NOTED
SEPARATELY MOUNTED CIRCUIT BREAKER; SEE
ELECTRICAL ONE-LINE DIAGRAM OR SCHEDULE
FOR DESCRIPTION
DISCONNECT OR DRAWOUT CONNECTION
ATS - AUTOMATIC
MTS - MANUAL
X - INDICATES TYPE
XXX
Y
X RECESSED FLOOR MOUNTED BOX, QUANTITY
AND TYPE OF RECEPTACLES AS INDICATED
X
ELECTRICAL EQUIPMENT ENCLOSURE
ESTIMATED SIZE AS INDICATED. WHEN USED
X INDICATES EQUIPMENT TYPE.
FUSED SAFETY SWITCH, 30A, 3P,
X INDICATES AMP RATING GREATER THAN 30A
Y INDICATES FUSE SIZE
MR - EQUIPMENT MANUFACTURER
RECOMMENDED FUSE SIZE
Y
X
X
2000AF
1800AT
3P Y
EQUIPMENT TYPES
ATS
CP
INV
MTS
MCC
UPS
VFD
SB
SG
T
AUTOMATIC TRANSFER SWITCH
CONTROL PANEL
LIGHTING INVERTER
MANUAL TRANSFER SWITCH
MOTOR CONTROL CENTER
UNINTERRUPTIBLE POWER SUPPLY
VARIABLE FREQUENCY DRIVE
SWITCHBOARD
SWITCHGEAR
TRANSFORMER
LOW VOLTAGE CIRCUIT BREAKER (CB). RATING
AND NO. OF POLES AS SHOWN. WHEN SPECIFIC
TYPE, OTHER THAN MCCB, IS REQUIRED.
X INDICATES TYPE
Y INDICATES TRIP UNIT TYPE
L S I G A
TRIP UNIT
LONG TIME PICKUP
SHORT TIME PICKUP
INSTANTANEOUS PICKUP
GROUND FAULT PICKUP
ARC ENERGY REDUCTION MODE
X
Y
X
Y
X
Y
CONDUIT CONNECTION TO EQUIPMENT
X
X
E - ELECTRICAL
M - MECHANICAL
K - KIRK KEY
INTERLOCK: X - INDICATES TYPE
TYPES
J OR
SV SOLENOID VALVE
RECEPTACLE SUBSCRIPTS
GENERAL NOTES
PROTECTION RELAY.
X - INDICATES IEEE FUNCTION NUMBER
X
AC
G
TR
USB
SPD
WP
Y - INDICATES CIRCUIT NUMBER FROM
AC
GROUND FAULT CIRCUIT INTERRUPTER
TAMPER RESISTANT
USB CHARGING STATION
SURGE PROTECTIVE DEVICE
WEATHERPROOF, IN-USE
PANELBOARD; PANEL NAME : CIRCUIT #
POLE - MOUNTED TRANSFORMER
EXTERIOR PAD MOUNTED TRANSFORMER
ELECTRICAL HANDHOLE OR MANHOLE
X - INDICATES SEQUENCE NUMBER
Y- MHX OR HHX
X
Y
POWER POLE
DOWNGUY
E UNDERGROUND (UNO) ELECTRICAL AND
COMMUNICATION SYSTEMS PATHWAY
OHE OVERHEAD ELECTRICAL AND COMMUNICATION
SYSTEMS PATHWAY
SITE SYMBOLOGY
1. DEMOLITION PLAN INDICATES A DESIRED SCOPE OF WORK. THE CONTRACTOR IS RESPONSIBLE TO VERIFY ALL WORK IN THE FIELD
PRIOR TO THE START OF WORK.
2. CONDITIONS MAY EXIST WHERE CABLING, DEVICES, FIXTURES, AND/OR EQUIPMENT IS INSTALLED WITHIN AN AREA OF DEMOLITION THAT IS INTENDED TO REMAIN IN ORDER TO KEEP SYSTEMS OUTSIDE OF THE AREA OF DEMOLITION IN OPERABLE CONDITION.
CONTRACTOR SHALL PROVIDE APPROPRIATE PROTECTION AND EXERCISE CARE WHEN PERFROMING DEMOLITION.
3. ALL SYSTEMS LOCATED OUTSIDE THE AREA OF DEMOLITION ARE INTENDED TO REMAIN OPERABLE
4. READ THE SPECIFICATIONS (PROJECT MANUAL) AND REVIEW DRAWINGS OF ALL DIVISIONS OF WORK. COORDINATE THE WORK HEREIN WITH ALL OTHER DIVISIONS OF WORK AND ALL SUBCONTRACTORS. PROVIDE ALL SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. REVIEW THE GENERAL NOTES, SPECIFICATIONS, AND DRAWINGS FOR ADDITIONAL REQUIREMENTS THAT MAY NOT BE SPECIFICALLY CALLED OUT IN THIS PORTION OF THE CONSTRUCTION DOCUMENTS. NOTIFY THE ENGINEER OF ANY CONFLICTS OR
DISCREPANCIES PRIOR TO SUBMISSION OF BID.
5. EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS AND SITE VISITS AND MAY NOT REFLECT EXACT 'AS-BUILT'
CONDITIONS. FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS.
6. COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS.
7. SERVICE SHALL BE MAINTAINED TO EXISTING AREAS DURING CONSTRUCTION. CONTRACTOR SHALL PROVIDE PORTABLE GENERATORS, CABLES, OUTLETS, ETC. AS REQUIRED TO MAINTAIN CONTINUITY OF SERVICE. PLACEMENT OF SUCH PORTABLE EQUIPMENT SHALL BE
SUBJECT TO OWNER APPROVAL.
8. VERIFY EXACT LOCATIONS OF EXISTING UNDERGROUND UTILITIES, PIPING, AND RACEWAYS PRIOR TO TRENCHING OR EXCAVATING.
9. PROVIDE NECESSARY TRENCHING, BACKFILL, EXCAVATION, SUPPORTS, FEEDERS, PULLBOXES, CONCRETE EQUIPMENT PADS, SAWCUTTING AND PATCHING, CONCRETE/PAVING, ETC. REQUIRED.
10. ALL PENETRATIONS THROUGH FIRE RATED WALLS, FLOORS, OR PARTITIONS ARE TO BE SEALED. THE FIRE RATING OF THE PENETRATION SEAL TO BE, AT A MINIMUM, THE SAME RATING AS THAT OF THE FLOOR OR WALL. REFER TO SPECIFICATIONS FOR
ADDITIONAL INFORMATION.
11. EXPOSED CONDUIT ARE TO BE INSTALLED IN STRAIGHT LINES, PARALLEL WITH OR AT RIGHT ANGLES TO THE BUILDING STRUCTURE.
12. EXISTING FIXTURES, DEVICES, ELECTRICAL EQUIPMENT, ETC. BEING REMOVED ARE TO BE RETURNED TO THE OWNER, EXCEPT FOR
THOSE ITEMS BEING RELOCATED OR REUSED.
13. FINAL CONNECTIONS TO EQUIPMENT SHALL BE IN ACCORDANCE WITH MANUFACTURER’S APPROVED WIRING DIAGRAMS, DETAILS, AND INSTRUCTIONS. IT IS THE CONTRACTOR’S RESPONSIBILITY TO PROVIDE MATERIALS AND EQUIPMENT COMPATIBLE WITH EQUIPMENT
ACTUALLY SUPPLIED.
14. CONTRACTOR IS RESPONSIBLE FOR REPLACING EQUIPMENT WHICH IS DAMAGED DUE TO INCORRECT INSTALLATION.
15. CONTRACTOR IS RESPONSIBLE FOR CAREFULLY COORDINATING WORK WITH ALL TRADES AND IS RESPONSIBLE FOR SECURING SPACE REQUIREMENTS FOR ELECTRICAL EQUIPMENT CLEARANCE AND CORRECT ROUGH-IN LOCATIONS OF ELECTRICAL CONNECTIONS.
16. CONTRACTOR IS RESPONSIBLE TO COORDINATE AND DETERMINE WHEN WORK SHALL BE INSTALLED TO AVOID CONFLICTS. ANY REWORK REQUIRED DUE TO FAILURE TO COORDINATE THE ELECTRICAL WORK WITH OTHER TRADES SHALL BE AT NO ADDITIONAL COST
TO THE GOVERNMENT.
17. PROVIDE IS AN INCLUSIVE TERM USED TO DESCRIBE ASPECTS OF
THE WORK, AND IS HEREBY DEFINED TO REQUIRE THE CONTRACTOR TO STORE, FURNISH, INSTALL, MOUNT, CONNECT, CONTROL, AND POWER EQUIPMENT INDICATED, AS WELL AS APPURTENANCES TO MAKE ELECTRICAL SYSTEMS OPERATE AS INDICATED WITHIN THESE
DRAWINGS AND SPECIFICATIONS.
ATO AUTOMATIC THROW OVER
BUSDUCT
OVERHEAD FEEDERS
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
T e xa s P
.E
F ir m
R e g is tr a ti o n N o
F -7
C
U s e rs
\B R
IJ
O
H N
S O
N \D o c u m e n ts
\R e v it \L o c a l F ile s \1
D
S C
R E
B
L D
G B
B ri a n .J o h n s o n W
J T
S .r v t
/1 /2
:1
:3
P M
E-001
BLDG 46
E L E
C T
R
IC
A L S
Y M
B O
L S
A N
D G
E N
E R
A L N
O T
E S
D E
F E
N S
E S
U P
P L Y
C E
N T
E R
R
IC
H M
O N
D
D S
C R
N O
R F
O L K
V
IR
G
IN
IA
H D
R E
N G
IN
E
E R
IN
G
I N
C
N
W L
P
S
U
IT
E
S A
N A
N T
O N
IO
T
X
B J O
H N
S O
N
B J O
H N
S O
N
D S
T E
P H
E N
S O
N
D E
C E
M B
E R
F A
-2
-F
-0
F A
-2
-D
-0
R T
A
B U
IL
D
IN
G
G
E N
E R
A T
O R
T
IE
-I N
GENERATOR 1
G
ENERATO
R 2
SHEET E-110
XFMR T58
XFMR T57
GEN CONN. CAB.
BLDG 46
NOT IN CONTRACT
ES102
B31B46
AREA OF WORK
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
T e xa s P
.E
F ir m
R e g is tr a ti o n N o
F -7
GENERAL NOTES
SHEET KEYNOTES
SHEET LEGEND
KEYPLAN
PLAN NORTH
C
U s e rs
\B R
IJ
O
H N
S O
N \D o c u m e n ts
\R e v it \L o c a l F ile s \1
D
S C
R E
B
L D
G B
B ri a n .J o h n s o n W
J T
S .r v t
/1 /2
:1
:3
P M
ES101
BLDG 46
O V
E R
A L L S
IT
E
P L A
N
D E
F E
N S
E S
U P
P L Y
C E
N T
E R
R
IC
H M
O N
D
D S
C R
N O
R F
O L K
V
IR
G
IN
IA
H D
R E
N G
IN
E
E R
IN
G
I N
C
N
W L
P
S
U
IT
E
S A
N A
N T
O N
IO
T
X
B J O
H N
S O
N
B J O
H N
S O
N
D S
T E
P H
E N
S O
N
D E
C E
M B
E R
F A
-2
-F
-0
F A
-2
-D
-0
R T
A
B U
IL
D
IN
G
G
E N
E R
A T
O R
T
IE
-I N
1" = 40'-0" A1
ELECTRICAL SITE PLAN
0 20' 40' 80'
SHEET E-110
XFMR T58XFMR T57 GEN CONN.
CAB.
NDPB NDPA
EDP
1 2
GENERATOR 1
G
ENERATO
R 2
ATS-C
ATS-UA
ATS-UB
ATS-LS
B31B46
AREA OF WORK
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
T e xa s P
.E
F ir m
R e g is tr a ti o n N o
F -7
GENERAL NOTES
SHEET KEYNOTES
SHEET LEGEND
KEYPLAN
PLAN NORTH
C
U s e rs
\B R
IJ
O
H N
S O
N \D o c u m e n ts
\R e v it \L o c a l F ile s \1
D
S C
R E
B
L D
G B
B ri a n .J o h n s o n W
J T
S .r v t
/1 /2
:1
:3
P M
ES102
BLDG 46
E N
L A
R G
E D
S
IT
E P
L A
N
D E
F E
N S
E S
U P
P L Y
C E
N T
E R
R
IC
H M
O N
D
D S
C R
N O
R F
O L K
V
IR
G
IN
IA
H D
R E
N G
IN
E
E R
IN
G
I N
C
N
W L
P
S
U
IT
E
S A
N A
N T
O N
IO
T
X
B J O
H N
S O
N
B J O
H N
S O
N
D S
T E
P H
E N
S O
N
D E
C E
M B
E R
F A
-2
-F
-0
F A
-2
-D
-0
R T
A
B U
IL
D
IN
G
G
E N
E R
A T
O R
T
IE
-I N
1 REMOVE CONDUCTORS FROM TRANSFORMERS T57 AND T58 TO SWITCHGEAR.
EXISTING CONDUIT BELOW THE SLAB TO BE REUSED FOR NEW FEEDERS.
2 REMOVE PORTABLE GENERATOR CABINET AND CONDUCTORS. UNDERGROUND
CONDUIT TO BE ABANDONED IN PLACE.
1EPC
1EPUB
1EPUA
1EPLS
EG-1
ANNUNCIATOR
EG-2
ANNUNCIATOR
1EHC
1XE1
1ELC
1LD31LD21DPD
1XD
LC1
1HD
1HF
LCU
NDPANDPB
TIE
1LD4
BUSWAY
FROM
GENERATORS
ATS-BATS-A
FROM
XFMR T57
FROM
XFMR T58
WIREWAY
EDP
1EPUA
ATS-UBATS-UA
1EPUB
ATS-C
1EPC
1EHC
ATS-LS
1EPLS
1XE1
1ELC
1LD41LD21DPD
1XD
LC1
1HD
1HF
LCU
NDPA
TIE
NDPB
EG-1
ANNUNCIATOR
EG-2
ANNUNCIATOR
1LD3
FROM
XFMR T57
FROM
XFMR T58
FROM
GENERATORS
FROM
XFMR T58
B31B46
AREA OF WORK
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
T e xa s P
.E
F ir m
R e g is tr a ti o n N o
F -7
GENERAL NOTES
SHEET KEYNOTES
SHEET LEGEND
KEYPLAN
C
U s e rs
\B R
IJ
O
H N
S O
N \D o c u m e n ts
\R e v it \L o c a l F ile s \1
D
S C
R E
B
L D
G B
B ri a n .J o h n s o n W
J T
S .r v t
/1 /2
:1
:3
P M
E-110
BLDG 46
P O
W E
R P
L A
N S
D E
F E
N S
E S
U P
P L Y
C E
N T
E R
R
IC
H M
O N
D
D S
C R
N O
R F
O L K
V
IR
G
IN
IA
H D
R E
N G
IN
E
E R
IN
G
I N
C
N
W L
P
S
U
IT
E
S A
N A
N T
O N
IO
T
X
B J O
H N
S O
N
B J O
H N
S O
N
D S
T E
P H
E N
S O
N
D E
C E
M B
E R
F A
-2
-F
-0
F A
-2
-D
-0
R T
A
B U
IL
D
IN
G
G
E N
E R
A T
O R
T
IE
-I N
0 4' 8' 16'
PLAN NORTH
1 ROUTE CONDUCTORS THROUGH SWITCHGEAR TO EXISTING UNDERGROUND
CONDUITS.
2 ROUTE CONDUCTORS FROM TRANSFORMER IN EXISTING UNDERGROUND
CONDUITS.
3 ROUTE CONDUCTORS FROM SWITCHGEAR IN EXISTING UNDERGROUND
CONDUIT TO ELECTRICAL GEAR.
4 REMOVE CONDUCTORS FROM TRANSFORMERS T57 AND T58 TO SWITCHGEAR.
EXISTING CONDUIT BELOW THE SLAB TO BE REUSED FOR NEW FEEDERS.
5 REMOVE CONDUCTORS FROM SWITCHGEAR TO EDP AND AUTOMATIC TRANSFER
SWITCHES. CONDUITS TO BE REUSED FOR NEW FEEDERS. CONDUITS NOT
REUSED ARE TO BE ABANDONED IN PLACE.
6 DISCONNECT FEEDERS FROM GENERATORS TO SWITCHBOARD EDP. FEEDERS
TO BE REUSED FOR NEW AUTOMATIC TRANSFER SWITCHES.
7 PROVIDE OVERHEAD MOUNTED BUSWAY FROM ATS TO SWITCHGEAR. BUSWAY-A
AND BUSWAY-B TO BE MOUNTED ONE ON TOP OF THE OTHER AND ARRANGED
SO THAT THE PHASES ARE DIRECTLY INLINE WITH THE BREAKER LUGS. PROVIDE
ALL PARTS AND PIECES NECESSARY FOR A COMPLETE AND OPERATIONAL
INSTALLATION. REFER TO ARCHITECTURAL PLANS FOR WALL PENETRATION.
8 PROVIDE WIREWAY TO ROUTE CONDUCTORS TO PANEL 1EPLS. EXTEND
UNDERGROUND CONDUITS UP TO THE WIREWAY AND ROUTE CONDUCTORS TO
1EPLS.
9 PROVIDE OVERHEAD FEEDERS FROM EXISTING BREAKERS TO EXISTING
PANELBOARDS. REFER TO ONE-LINE DIAGRAM FOR MORE INFORMATION.
10 ROUTE CONDUCTORS THROUGH SWITCHGEAR AND UP THROUGH TIE SECTION
OVERHEAD TO ATS-B.
11 PROVIDE ELBOW UNDERGROUND TO MAKE CONDUITS CONTINUOUS.
12 PROVIDE OVERHEAD FEEDERS FROM SWITCHGEAR TO ATS-B.
13 FIELD VERIFY GENERATOR CONDUCTOR LENGTH TO TERMINATE ON NEW
EQUIPMENT. SPLICE AND EXTEND FEEDERS AS NEEDED.
1/4" = 1'-0" A2
NEW WORK POWER PLAN
1/4" = 1'-0" H2
DEMOLITION POWER PLAN
A. REFER TO STRUCTURAL DRAWINGS FOR CONCRETE WORK.
B. PATCH/REPAIR/PAINT WALL ASSEMBLIES WHERE ELECTRICAL DEMOLITION AND
NEW WORK OCCUR. MATCH EXISTING FINISH AND APPEARANCE.
C. VERIFY THE EXACT LOCATION OF ALL UNDERGROUND CONDUITS AND UTILITIES.
NOTIFY THE ENGINEER OF ANY DISCREPENSIES.
D. ALL REMOVED EQUIPMENT SHALL BE RETURNED TO THE GOVERNMENT.
E. EQUIPMENT SHOWN WITH DASHED LINES ARE TO BE REMOVED.
F. EQUIPMENT SHOWN IN GREY IS EXISTING TO REMAIN.
0 4' 8' 16'
PLAN NORTH
MCB-A
4000AF
3200AT
3P
LSIG
N.C.
DMP
800AF
225AT
3P
LSIG
N.C.
1600AF
1200AT
3P
LSIG
N.C.
800AF
300AT
3P
LSIG
N.C.
800AF
800AT
3P
LSIG
N.C.
800AF
400AT
3P
LSIG
N.C.
800AF
100AT
3P
LSIG
N.C.
1600AF
1200AT
3P
LSIG
N.C.
800AF
150AT
3P
LSIG
N.C.
1600AF
1600AT
3P
LSIG
N.C.
MCB-A
4000AF
3200AT
3P
LSIG
N.C.
1600AF
1600AT
3P
LSIG
N.C.
800AF
175AT
3P
LSIG
N.C.
800AF
400AT
3P
LSIG
N.C.
800AF
100AT
3P
LSIG
N.C.
800AF
300AT
3P
LSIG
N.C.
800AF
450AT
3P
LSIG
N.C.
800AF
800AT
3P
LSIG
N.C.
800AF
450AT
3P
LSIG
N.C.
800AF
450AT
3P
LSIG
N.C.
DMP
MCB-T
4000AF
3200AT
3P
LSIG
N.O.
K
2000AF
2000AT
3P
LSIG
N.C.
800AF
400AT
3P
LSI
N.C.
SPARE
800AF
800AF
800AT
3P
LSIG
N.C.
800AF
800AT
3P
LSIG
N.C.
G
2500A 3P
2000AF
2000AT
3P
LSIG
N.O.
DMPGFS
1600AF
1200AT
3P
LSIG
N.C.
SPARE
1600AF
2000AF
2000AT
3P
LSIG
N.C.
G
2500A 3P
GFS
GFS
400A 3P
60A 3P
800A 3P
800A 3P
800A 3P
800A 3P
600A 3P
400A 3P
1200A 3P
800A 3P
800A 3P
175A 3P
175A 3P
(E)XFMR T57
2500KVA
13,200:480/277V, 3PH
(E)
PANEL
1HF
(E)
CHILLER
C-1
(E)
PANEL
1HC
(E)
PANEL
1DPM
(E)
XFMR
1XC
(E)
BUSDUCT
NHA
(E)
BUSDUCT
NHB
(E)
PANEL
1DPD
(E)
PANEL
1HK
(E)
PANEL
1HD
(E)
CHILLER
C-2
(E)
PANEL
1DPK
(E)
HRCH-1
CKT #1
(E)
HRCH-1
CKT #2
(E)XFMR T58
2500KVA
13,200:480/277V, 3PH
(E) SWICHGEAR 'NDPB'
4000A
480/277V, 3PH, 4W, 85KAIC
(E) SWICHGEAR 'NDPA'
4000A
480/277V, 3PH, 4W, 85KAIC
SPACE SPACE
(E) GENERATOR EG-1
1500KW
480/277V, 3PH
(E) SWICHGEAR 'EDP'
2000A
480/277V, 3PH, 4W
85KAIC
(E) ATS-LS
400A, 480/277V, 4 POLE
BYPASS ISOLATION
65K SCCR
(E) ATS-UB
800A, 480/277V, 4 POLE
BYPASS ISOLATION
65K SCCR
(E) ATS-UA
800A, 480/277V, 4 POLE
BYPASS ISOLATION
65K SCCR
(E) ATS-C
1200A, 480/277V, 4 POLE
BYPASS ISOLATION
65K SCCR
(E) GENERATOR EG-2
1500KW
480/277V, 3PH
(E) PORTABLE GENERATOR
CONNECTION CABINET
2000A
480/277V, 3PH, 4W
(E) PANEL 1EPLS
400A
480/277V, 3PH, 4W
65KAIC
(E)
PANEL
1EHC
(E)
BUSDUCT
EHA
(E) PANEL 1EPUB
800A, 480/277V, 3PH, 4W
65KAIC
(E)
UPS-A
(E)
UPS-B
BYPASS
(E) PANEL 1EPUA
800A
480/277V, 3PH, 4W
65KAIC
(E)
UPS-A
BYPASS
(E)
UPS-B
(E) PANEL 1EPC
1200A, 480/277V, 3PH, 4W
65KAIC
(E)
PANEL
1ECA
(E)
PANEL
1ECD
(E)
XFMR
1XE1
(E)
XFMR
1XE2
N
G
N
G
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
T e xa s P
.E
F ir m
R e g is tr a ti o n N o
F -7
GENERAL NOTES
SHEET KEYNOTES
SHEET LEGEND
C
U s e rs
\B R
IJ
O
H N
S O
N \D o c u m e n ts
\R e v it \L o c a l F ile s \1
D
S C
R E
B
L D
G B
B ri a n .J o h n s o n W
J T
S .r v t
/1 /2
:1
:3
P M
E-601
BLDG 46
D E
M O
L
IT
IO
N
O N
E -L
IN
E
D
IA
G R
A M
D E
F E
N S
E S
U P
P L Y
C E
N T
E R
R
IC
H M
O N
D
D S
C R
N O
R F
O L K
V
IR
G
IN
IA
H D
R E
N G
IN
E
E R
IN
G
I N
C
N
W L
P
S
U
IT
E
S A
N A
N T
O N
IO
T
X
B J O
H N
S O
N
B J O
H N
S O
N
D S
T E
P H
E N
S O
N
D E
C E
M B
E R
F A
-2
-F
-0
F A
-2
-D
-0
R T
A
B U
IL
D
IN
G
G
E N
E R
A T
O R
T
IE
-I N
NTS
OVERALL DEMOLITION ONE-LINE DIAGRAM
1 REMOVE CONDUCTORS FROM SWITCHGEAR TO EDP AND AUTOMATIC TRANSFER
SWITCHES. CONDUITS TO BE REUSED FOR NEW FEEDERS. CONDUITS NOT REUSED
ARE TO BE ABANDONED IN PLACE.
2 REMOVE CONDUCTORS FROM TRANSFORMERS T57 AND T58 TO SWITCHGEAR.
EXISTING CONDUIT BELOW THE SLAB TO BE REUSED FOR NEW FEEDERS.
3 REMOVE PORTABLE GENERATOR CABINET AND CONDUCTORS. UNDERGROUND
CONDUIT TO BE ABANDONED IN PLACE.
4 REMOVE EXISTING NEUTRAL-GROUND BOND.
A. CONTRACTOR TO PERFORM PHASING AND WORK IN A WAY TO SHUTDOWN
INDIVIDUAL FEEDER BREAKERS IN SWITCHGEAR NDPA OR NDPB TO THE GREATEST
EXTENT POSSIBLE.
B. WHEN SWITCHGEAR NDPA OR NDPB REQUIRES COMPLETE SHUTDOWN, ALL WORK
MUST BE COMPLETED AFTER HOURS. FOR EXTENDED SHUTDOWNS, THE
CONTRACTOR IS REQUIRED TO COORDINATE WITH THE GOVERNMENT TO
PERFORM WORK ON WEEKENDS AND/OR HOLIDAYS.
MCB-A
4000AF
3200AT
3P
LSIG
N.C.
DMP
800AF
225AT
3P
LSIG
N.C.
1600AF
1200AT
3P
LSIG
N.C.
800AF
300AT
3P
LSIG
N.C.
800AF
800AT
3P
LSIG
N.C.
800AF
400AT
3P
LSIG
N.C.
800AF
100AT
3P
LSIG
N.C.
1600AF
1200AT
3P
LSIG
N.C.
800AF
150AT
3P
LSIG
N.C.
1600AF
1600AT
3P
LSIG
N.C.
MCB-A
4000AF
3200AT
3P
LSIG
N.C.
1600AF
1600AT
3P
LSIG
N.C.
800AF
175AT
3P
LSIG
N.C.
800AF
400AT
3P
LSIG
N.C.
800AF
100AT
3P
LSIG
N.C.
800AF
300AT
3P
LSIG
N.C.
800AF
450AT
3P
LSIG
N.C.
800AF
800AT
3P
LSIG
N.C.
800AF
450AT
3P
LSIG
N.C.
800AF
450AT
3P
LSIG
N.C.
DMP
MCB-T
4000AF
3200AT
3P
LSIG
N.O.
400A 3P
60A 3P
600A 3P
400A 3P
1200A 3P
175A 3P
175A 3P
G
2500A 3P
G
2500A 3P
3200.4U 3200.4
800.41200.4800.4400.4
800A 3P
800A 3P
800A 3P
800A 3P
800A 3P
800A 3P
XFMR T57
2500KVA
13,200:480/277V, 3PH
PANEL
1HF
CHILLER
C-1
PANEL
1HC
PANEL
1DPM
XFMR
1XC
BUSDUCT
NHA
BUSDUCT
NHB
PANEL
1DPD
PANEL
1HK
PANEL
1HD
CHILLER
C-2
PANEL
1DPK
HRCH-1
CKT #1
HRCH-1
CKT #2
XFMR T58
2500KVA
13,200:480/277V, 3PH
SWITCHGEAR 'NDPB'
4000A
480/277V, 3PH, 4W, 85KAIC
SWITCHGEAR 'NDPA'
4000A
480/277V, 3PH, 4W, 85KAIC
SPACE SPACE
PANEL 1EPLS
400A
480/277V, 3PH, 4W
65KAIC
PANEL
1EHC
BUSDUCT
EHA
PANEL 1EPC
1200A, 480/277V, 3PH, 4W
65KAIC
PANEL
1ECA
PANEL
1ECD
XFMR
1XE1
XFMR
1XE2
ATS-B
3200A, 480/277V, 4 POLE
BYPASS ISOLATION
65K SCCR
SE RATED
ATS-A
3200A, 480/277V, 4 POLE
BYPASS ISOLATION
65K SCCR
SE RATED
GENERATOR EG-1
1500KW
480/277V, 3PH
GENERATOR EG-2
1500KW
480/277V, 3PH
(E) (E)
3200A BUSWAY 3200A BUSWAY
PANEL 1EPUB
800A, 480/277V, 3PH, 4W
65KAIC
UPS-A UPS-B
BYPASS
PANEL 1EPUA
800A
480/277V, 3PH, 4W
65KAIC
UPS-A
BYPASS
UPS-B
N
G
N
G
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
T e xa s P
.E
F ir m
R e g is tr a ti o n N o
F -7
C
U s e rs
\B R
IJ
O
H N
S O
N \D o c u m e n ts
\R e v it \L o c a l F ile s \1
D
S C
R E
B
L D
G B
B ri a n .J o h n s o n W
J T
S .r v t
/1 /2
:1
:3
P M
E-602
BLDG 46
N E
W O
N E
-L
IN
E D
IA
G
R A
M
D E
F E
N S
E S
U P
P L Y
C E
N T
E R
R
IC
H M
O N
D
D S
C R
N O
R F
O L K
V
IR
G
IN
IA
H D
R E
N G
IN
E
E R
IN
G
I N
C
N
W L
P
S
U
IT
E
S A
N A
N T
O N
IO
T
X
B J O
H N
S O
N
B J O
H N
S O
N
D S
T E
P H
E N
S O
N
D E
C E
M B
E R
F A
-2
-F
-0
F A
-2
-D
-0
R T
A
B U
IL
D
IN
G
G
E N
E R
A T
O R
T
IE
-I N
FEEDER SCHEDULE
TAG # OF SETS
# OF
WIRES Wire Size GROUND CONDUIT
400.4 2 4 250 KCMIL 1-2 AWG (E) 4"
800.4 2 4 500 KCMIL 1-1/0 AWG 4"
1200.4 4 4 350 KCMIL 1-3/0 AWG (E) 4"
3200.4 9 4 500 KCMIL - 4"
3200.4U 9 4 500 KCMIL - (E) 4"
A. CONTRACTOR TO PERFORM PHASING AND WORK IN A WAY TO SHUTDOWN
INDIVIDUAL FEEDER BREAKERS IN SWITCHGEAR NDPA OR NDPB TO THE GREATEST
EXTENT POSSIBLE.
B. WHEN SWITCHGEAR NDPA OR NDPB REQUIRES COMPLETE SHUTDOWN, ALL WORK
MUST BE COMPLETED AFTER HOURS. FOR EXTENDED SHUTDOWNS, THE
CONTRACTOR IS REQUIRED TO COORDINATE WITH THE GOVERNMENT TO
PERFORM WORK ON WEEKENDS AND/OR HOLIDAYS.
SHEET KEYNOTES
GENERAL NOTES
1 PROVIDE #3/0 GROUNDS TIED INTO EQUIPMENT GROUNDING BAR IN MAIN
SWITCHGEAR ROOM.
| GENERAL |
| G-001 - COVER SHEET |
| STRUCTURAL |
| S-001 - GENERAL STRUCTURAL NOTES |
| S-002 - STRUCTURAL SPECIAL INSPECTIONS |
| S-003 - TYPICAL CONCRETE DETAILS 1 |
| SD101 - FIRST FLOOR DEMOLITION PLAN |
| S-100 - FIRST FLOOR FRAMING PLAN |
| ELECTRICAL |
| E-001 - ELECTRICAL SYMBOLS AND GENERAL NOTES |
| ES101 - OVERALL SITE PLAN |
| ES102 - ENLARGED SITE PLAN |
| E-110 - POWER PLANS |
| E-601 - DEMOLITION ONE-LINE DIAGRAM |
| E-602 - NEW ONE-LINE DIAGRAM |
File details come from the government source that posted it. Updated .