This Performance Work Statement (PWS) details requirements for latrine and septic services at Cannon Air Force Base (CAFB) and Melrose Air Force Range (MAFR) in New Mexico. The contractor will provide comprehensive services including delivering, maintaining, servicing, and removing portable chemical latrines and hand wash stations across multiple locations, as well as pumping domestic wastewater holding and septic tanks.

Key service requirements include weekly servicing of standard latrines at designated static locations, handling quantities ranging from 1 to over 50 latrines depending on the event, and maintaining latrines with specific standards such as tight-fitting doors, ventilation, and pest prevention. The contractor must use environmentally safe chemicals, properly manage waste, and follow strict environmental and safety protocols. Service locations include CAFB, Cannon Permanent Exercise Facility (CPEF), MAFR, Melrose Permanent Exercise Facility (MPEF), and various remote sites throughout eastern New Mexico. The contract period appears to cover multiple years, with estimated workload data provided for periods from March 2025 to February 2030.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PERFORMANCE WORK STATEMENT

FOR

LATRINE AND SEPTIC SERVICE

Cannon Air Force Base, New Mexico

6 December 2024

Contract: Pending LATRINE AND SEPTIC SERVICE Attachment 1 Solicitation: FA4855-xx-x-xxxx Performance Work Statement 6 December 2024

1. DESCRIPTION OF SERVICES. The contractor shall provide all labor, equipment, transportation, and other items and services necessary to provide chemical latrines and to provide pumping services for domestic wastewater holding tanks and septic tanks in compliance with all Federal, State and local laws and regulations. The contractor shall provide, maintain and service portable chemical latrines (standard and handicap accessible) and hand wash stations at Cannon Air Force Base (CAFB), Cannon Permanent Exercise Facility (CPEF), Melrose Air Force Range (MAFR), Melrose Permanent Exercise Facility (MPEF) and remote sites throughout Eastern New Mexico, and to pump domestic wastewater holding and septic tanks at those locations. At the end of the performance period, the latrines and hand wash stations will not become the property of the Government.

1.1. LATRINES AND HAND WASH STATIONS.

1.1.1. Latrines shall be well-ventilated, with self-closing doors, inside lock/latch, tight-fitting door seals and screen material to prevent pest intrusion and accumulation of filth. Latrine unit quantities may range from 1 to over 50, depending upon the situation or event. Small quantities of latrines (static locations and remote sites) may be utilized long-term (e.g., 1-5 years). Large quantities of latrines (e.g., 30-60) and hand wash stations (e.g., 5-10) may be utilized for short-term events (e.g., 1-2 days), such as an Open House or Air Show and shall include servicing and replenishment of supplies after the first day’s event.

1.1.2. Latrines shall be furnished at static locations and remote sites (Attachments B and C).

Workload requirements may increase or decrease as needed to support mission requirements.

Each unit will be set up (to include shimming/leveling), maintained and serviced. As a minimum, units at CAFB static locations shall be serviced weekly; MAFR static locations and remote sites shall be serviced once per month from 1 October - 31 March and twice per month from 1 April - 30 September. The contractor shall use an environmentally safe chemical in the waste tank specifically designed for portable latrines during cold weather to prevent the freezing of waste in the tanks. Coordinate with the COR at minimum, two weeks prior, for approval of chemicals prior to usage/delivery on base (see Forms C-4, CAFB & MAFR Contractor HAZMAT Worksheet and C-5, CAFB & MAFR Contractor HAZMAT Instructions).

1.2. DELIVER AND SET UP LATRINES AND HAND WASH STATIONS. The contractor shall make timely delivery and set up of units. Delivery shall be performed in accordance with the task order issued by the Contracting Officer (CO), Contracting Specialist (CS), or Contracting Officer Representative (COR). Delivery includes completed placement and set up actions to make the unit ready for customer use at the specified location. The contractor is responsible for ensuring latrines and hand wash stations stay upright and in place for anticipated wind conditions.

1.2.1. Sandbags, or equivalent materials, provided by the contractor, are acceptable for use when arranged in a neat and professional manner.

Contract: Pending LATRINE AND SEPTIC SERVICE Attachment 1

1.2.2. Stakes may be used to secure units, however, may not exceed 4” in length. If the contractor intends to drive stakes into the ground on CAFB, a completed 27 SOCES Form 103, Base Civil Engineering Work Clearance Request (also known as a Dig Permit) is required before breaking ground (Attachment C-2). 27 SOCES conducts Work Clearance Request briefings with contractors to process Work Clearance Requests. Briefings are held in the 27 SOCES Conference Room, Building 355, 506 N Air Commando Way, every Thursday morning at 7:30am, excluding holidays. The contractor shall attend a briefing if their Work Clearance Request is being processed.

1.3. SERVICE LATRINES AND HAND WASH STATIONS. Contractor shall provide comprehensive service and maintenance on a weekly basis for the three designated static locations at the (1) Motorcycle Training Area, west of Bldg. 1820, (2) Softball Fields, (3) Portales Gate Vehicle Inspection Area (Bldg. 2260). Services consist of cleaning the inside and outside of the latrines, disinfecting the interior including the toilet seat and urinal, providing air freshener and a minimum of two full rolls of toilet paper for each latrine; pumping waste materials and replenishing the chemical effectiveness of the liquid chamber for each latrine; and sanitizing and replenishing fresh water, paper products and hand sanitizer (soap) for each hand wash station. The contractor shall avoid waste transfer onto surfaces outside of container opening and is responsible for applicable cleanup of waste transfer from surfaces outside of container opening. The contractor is responsible for cleanup of any chemical product or waste spills and must immediately notify the Cannon Fire Dept as well as the COR of any instances. Additional involvement from CE Environmental may also be required (see Section 4.7.3). The contractor shall dispose of all waste, materials, empty containers, etc., off of CAFB and MAFR property at an off-base permitted site in accordance with all applicable Federal, State, and local laws and regulations. The contractor shall ensure all latches, hinges, vents, hoses and attached accessories are maintained and in working order at no extra cost to the Government.

1.3.1. Inaccessible Latrines. The contractor shall attempt to service each latrine. If the latrine is inaccessible due to weather or access road conditions, the contractor will notify the COR within 24 hours or upon the next duty day. Government personnel will not be sent to clear snow/ice from around the latrine nor is the contractor expected to clear snow/ice from around the latrine.

The Government will not be responsible if a contractor vehicle becomes stuck attempting to access impassible roads.

1.3.2. Blown/Knocked Over Latrines. If tipping occurs, or the stakes that hold the latrines are no longer secured, the contractor shall set the latrine upright at no additional cost to the Government. Re-staking/righting a tipped latrine shall be performed as soon as possible, but at maximum within 4 hours of notification since hazmat/hazardous waste spills may be a factor.

The contractor shall clean any spillage resulting from blown/knocked over latrines. The contractor shall not dig deeper than 2” to clean any spilled chemicals. For spills, notification of the COR is required as well, with additional assessment from CE Environmental.

Contract: Pending LATRINE AND SEPTIC SERVICE Attachment 1

1.3.3. Vandalism. The contractor shall report, in writing, acts of vandalism, theft, or apparent willful act of damage of latrines to the CO. The contractor shall cooperate with Government personnel and provide a written statement of facts for Law Enforcement personnel, when requested.

1.4. REMOVE LATRINES AND HAND WASH STATIONS. The contractor shall pick up and remove all latrines and hand wash stations at the end of the period of performance of the contract or in accordance with the instructions/dates issued on the work order. Removal includes any sanitary service actions required for the contractor’s retrieval of the unit. The contractor shall ensure the equipment, service products and related items/debris are removed from the area.

1.5. PUMP HOLDING AND SEPTIC TANKS. Services shall include pumping waste materials, only leaving minimal residue in the tank. The contractor shall dispose of all waste materials, empty containers, etc. off of CAFB and MAFR property in accordance with all applicable Federal, State, local laws and regulations. The contractor shall avoid waste transfer onto surfaces outside of tank opening and is responsible for applicable cleanup of waste transfer from surfaces outside of tank opening. The contractor shall securely close the tank opening upon completion of pumping. The contractor is responsible for cleanup of any chemical product or waste spills. The contractor shall dispose of all waste at an off-base permitted site.

1.5.1. Manifests. The Contractor shall provide a manifest to the COR within 10 calendar days after the end of the quarter detailing the name of the hauler, the date of off-site shipment, the volume of solids removed, the location from which the solids were pumped, the disposal method, and disposal location (Cannon AFB, DP-873, Subsection A of 20.6.2.3107 NMAC).

1.6. WORK ORDERS. All task orders will be approved by the Contracting Officer (CO), Contracting Specialist (CS), or Contracting Officer Representative (COR). Work orders shall specify CLIN item(s), description, quantities, locations, date of service and removal, and other applicable information (Attachment C-1).

1.6.1. CAFB, Cannon Permanent Exercise Facility (CPEF), MAFR and Melrose Permanent Exercise Facility (MPEF). On occasion, services may be required to support a short-notice emergency, activation, exercise or requirement (e.g., facility water outage, emergency cleaning, emergency pumping). The contractor shall meet the short-notice requirement within 8 hours. In the event that this time requirement is not needed, such as for a planned outage, the COR will coordinate for timely, less stringent delivery 24-48 hours in advance.

1.7. EMERGENCY SERVICING. Emergency servicing is defined as servicing that is required after normal duty hours (Mon-Fri, 0700-1600). Only authorized Contracting Officer Representatives (COR) or the Contracting Officer (CO) may initiate an emergency service request. The COR or the CO is responsible for ensuring that there are funds available on the

Contract: Pending LATRINE AND SEPTIC SERVICE Attachment 1

Emergency Service Contract Line-Item Number (CLIN). The COR will notify the CO as soon as possible after an emergency service has been requested.

2. SERVICES SUMMARY (SS). The contract service requirements are summarized in Performance Objectives (PO) that relate directly to essential mission needs. The Performance Threshold briefly describes the minimally acceptable levels of service for each requirement. The SS provides information on contract requirements, the expected level of contractor’s performance and the expected method of Government validation and confirmation of services provided.

Performance Objective

PWS

Paragraph

Performance Threshold (per surveillance)

Method of Assessment

PO-1, Deliver and Set Up Latrines and Hand Wash Stations

1.2, inclusive

No more than 3 defects

Customer Complaint;

Periodic Validation

PO-2, Service Latrines and Hand Wash Stations

1.3, inclusive

No more than 3 defects

Customer Complaint;

Periodic Validation

PO-3, Remove Latrines and Hand Wash Stations

1.4 No more than 3

defects

Customer Complaint;

Periodic Validation

PO-4, Pump Holding and Septic Tanks 1.5 No more than 3 defects Customer Complaint;

Periodic Validation

2.1. QUALITY CONTROL. The contractor shall provide adequate quality control to ensure that all required service tasks are performed in accordance with commonly accepted commercial practices.

2.2. QUALITY ASSURANCE. The Government will inspect and evaluate the contractor's performance to ensure services are received in accordance with the requirements set forth in this PWS. The COR shall inspect by validating actual work performance, physically inspecting an attribute of the completed task, checking a management information report, investigating customer complaints, conferring with facility managers or otherwise inspecting the task or its results to determine whether or not performance meets the standards contained in this PWS.

Results of the validation then become the official Air Force record of the contractor’s performance. When a performance threshold has not been accomplished, the COR will initiate and provide the CO a DD Form 2772, Corrective Action Report (CAR), for issuance to the contractor. The contractor shall respond to the CAR, as directed by the CO, IAW the instructions provided and return it to the CO within three (3) calendar days of receipt (Attachment C-3).

Contract: Pending LATRINE AND SEPTIC SERVICE Attachment 1

2.3. RE-PERFORMANCE OF SERVICE. When service performed does not conform with contract requirements, the contractor shall re-perform at no additional cost to the Government.

Performance or re-performance of these services shall commence immediately upon notification by the CO and should occur within 24 hours. See Section 2, Services Summary.

2.4. PROGRESS MEETINGS. The contractor may be required to meet at least weekly with the CO and the COR during the first month of the contract. Subsequent meetings will be on an as needed basis. However, the contractor may request a meeting through the CO.

3. GOVERNMENT-FURNISHED PROPERTY. None

4. GENERAL INFORMATION.

4.1. PERSONNEL. Contractor personnel shall present a neat appearance and be easily recognized as contractor employees. All employees performing on this contract must be clearly able to read, write, speak, and understand English.

4.1.1. Contract Manager. The contractor shall provide a Contract Manager who shall be responsible for the performance of the work. The name of this person and an alternate(s), who shall act for the contractor when the Contract Manager is absent, shall be designated in writing, with daytime contact information (email address, work and cell phone numbers), to the CO at least 2 days prior to contract performance. An email address is required for submission of work orders from the COR.

4.1.2. Employees. The Government has the right to restrict the employment of any contractor employee, or prospective contractor employee, who is identified as a potential threat to the health, safety, security, general well-being or operational mission of the installation and its population.

4.1.3. The contractor shall not employ any person who is an employee of the United States Government if the employment of that person would create a conflict of interest. The contractor shall not employ any person who is an employee of the Department of the Air Force, either military or civilian, unless such person seeks and receives approval in accordance with Department of the Air Force (DAF) Standards of Ethical Conduct Rules.

4.1.4. Listing of Employees. The contractor shall provide a list to the CO of all personnel who will require access to CAFB or MAFR for performance IAW this PWS (see Attachment D). The contractor shall ensure the pass and identification items required for contract performance are obtained for employees. Contractor employees are required to have a favorable National Background check prior to being allowed on the installation. The Pass and Identification Section of 27th Special Operations Security Forces Squadron (27 SOSFS) will provide base entry authorizations/passes to each authorized contractor employee which will be facilitated by the COR and CO/CS. In addition, contractor personnel wishing to operate a privately-owned or

Contract: Pending LATRINE AND SEPTIC SERVICE Attachment 1 commercial vehicle on CAFB must comply with all applicable state and base requirements.

Entry authorizations must be renewed as required by the 27 SOSFS Pass and Identification Section. Submission of renewal pass forms shall be provided to the COR at least one month in advance of pass expiration.

4.1.5. Retrieving Identification Media. The contractor shall retrieve all identification media, including vehicle passes, from employees who depart for any reason before the contract expires (e.g. terminated for cause, retirement, etc.).

4.2. SECURITY REQUIREMENTS.

4.2.1. CAFB Access. Contractor personnel shall not enter any restricted or controlled areas without proper security escort. Anticipate delays in getting commercial vehicles on base and allow time for commercial vehicles to reach their destination by driving designated routes at posted speed limits throughout the base. Procedures for commercial vehicle access to the base are subject to change.

4.2.1.1. Airfield Drivers Training. A special event (i.e., Air Show, Open House) may require the delivery of latrines and hand wash stations to facilities adjacent to the airfield. Airfield drivers training must be completed prior to operating vehicles on the airfield (Attachment D). Airfield Management conducts training in a classroom setting, and employees are required to attend the course and pass a written test. The training session and testing may take 1-3 hours to complete.

Upon successful completion, employees will be issued an AF IMT 483, Certificate of Competency, for airfield driving. All employees driving on the airfield are required to always have a valid driver’s license and AF IMT 483 with them. The contractor shall contact the COR to schedule training appointments through the Deputy Airfield Manager.

4.2.1.2. Privately Owned Vehicle (POV) Passes. Vehicles must have a valid POV pass issued by Airfield Management prior to operating on the airfield. The contractor shall provide Airfield Management with the following information for each vehicle that will be operated on the airfield: Year, make, model, and color of each vehicle, license plate number, proof of insurance and vehicle registration (Attachment D). At no time will equipment be left unattended while working in these areas. The contractor shall be responsible for ensuring that all foreign objects and debris produced from this contract is removed before leaving the work area.

4.2.2. MAFR Access. The contractor may be required to deliver, relocate and provide cleaning service on short notice throughout MAFR and at remote sites. The contractor shall ensure entry authorizations are completed as required by MAFR officials. All drivers on MAFR must receive Range Safety Officer training. Training is offered each Tuesday by appointment only. The contractor should be prepared to experience delays entering MAFR. The contractor shall agree to comply with MAFR Standard Operating Procedures (SOP’s) before performance start (Attachment F).

Contract: Pending LATRINE AND SEPTIC SERVICE Attachment 1

4.2.2.1. The Government will provide a radio upon entry to the MAFR. The contractor shall maintain radio contact with the Range Control Officer (RCO) and monitor radios at all times while on the MAFR. The contractor shall ask for approval for all movement on the MAFR from the RCO (“Ground Control”). At no time should the contractor move on the MAFR without Ground Control approval. All equipment issued to contractor employees must be returned when leaving the MAFR each day. It is not required to monitor range frequencies when servicing remote sites not on the MAFR.

4.2.2.2. The contractor will schedule all visits to MAFR in Center Scheduling Enterprise (CSE) through the COR to receive a mission number in accordance with Chapter 3 of 27 SOAOS SOP 13-212 (Attachment F). No contractor will gain access to MAFR without a scheduled mission number.

4.2.3. Reporting Requirements. Contractor personnel shall report to an appropriate authority any information or circumstances of which they are aware may pose a threat to the security of DoD personnel, Contractor personnel, resources, and classified or unclassified defense information.

Contractor employees shall be briefed by their immediate supervisor upon initial on-base assignment.

4.2.4. Force Protection Condition (FPCON). Levels may change for real-world events or for exercise scenarios which may prevent contractor employees from entering or leaving CAFB until the situation has lessened. Depending on the situation, contractor employees shall react to FPCON requirements and guidance provided through the CO or COR.

4.3. VEHICLES. The contractor shall provide and maintain all vehicles necessary to perform the requirements of this contract. The contractor may be required to place latrines in many areas that have rough or sandy terrain. Appropriate vehicles/equipment to access these areas are required. Contractor vehicles shall have the company name prominently displayed on both sides of the vehicles. Vehicles shall be clean and always have a neat, professional appearance. All vehicles shall be in operable condition and meet New Mexico safety requirements. Vehicle repairs shall not be accomplished on CAFB or MAFR. Equipment failure shall not alleviate the contractor from performing any requirement contained in this contract.

4.3.1. Only qualified operators shall be permitted to operate the vehicles or equipment required by this contract. Vehicle/equipment operators shall possess a valid driver’s license.

4.3.2. Weapons, Firearms, and Ammunition. Contractor employees are prohibited from possessing weapons, firearms, or ammunition, on themselves or within their contractor-owned vehicles or privately-owned vehicle while on CAFB or MAFR.

4.3.3. Traffic Laws. The contractor and contractor employees shall comply with all base traffic regulations. The contractor is not permitted to use cell phones on CAFB or MAFR while operating a moving vehicle unless the device is hands-free.

Contract: Pending LATRINE AND SEPTIC SERVICE Attachment 1

4.4. WORK HOURS. Normal work hours at CAFB are 0700 to 1600, Monday through Friday, except for Federal Holidays (listed below). Normal operations hours at the MAFR are 0800- 0200, Monday through Friday. The contractor shall deliver/service latrines at the MAFR during daylight normal operations hours. The contractor may be required to perform requirements IAW this PWS outside of normal work hours/during the weekend depending on mission requirements or emergencies.

New Year’s Day Labor Day Martin Luther King Day Columbus Day Washington’s Birthday Veterans Day Memorial Day Thanksgiving Day Juneteenth Day Christmas Day Independence Day

4.5. SECURITY FORCES AND FIRE PROTECTION SERVICES.

4.5.1. CAFB. Contact the appropriate agency in case of emergency by dialing 911 from a base telephone. If calling from a cell phone or an off-base telephone, the following numbers apply:

Fire: 575-784-2578, Police: 575-784-4111, Command Post: 575-784-2253. If dialing 911 from a cell phone, the call may be automatically routed to an off-base agency, such as the city of Clovis, NM. Be clear about whom you are communicating with and what your situation requires.

4.5.2. MAFR. There is limited medical response on the MAFR and only civilian response outside of the MAFR for emergencies. In the event of a medical emergency on the MAFR, the contractor shall immediately notify the RCO by radio stating “Ground Control [call sign], I need to declare a medical emergency.” Then follow the direction of the RCO and provide the information requested.

4.5.2.1. Reporting of Fires. The contractor shall immediately report any observed fire on the MAFR to the RCO.

4.6. ENVIRONMENTAL MANAGEMENT SYSTEM (EMS). All Contractor personnel shall complete EMS Awareness training prior to commencement of any activities. Training is available through the learning management system called The Environmental Awareness Course Hub (TEACH) at https://cs2.eis.af.mil/sites/10040/WPP/LMS/Installation%20Home.aspx?InstallationID=98&Inst allationName=Cannon. Once on the SharePoint site, scroll down to EMS General Awareness Training and click “View Training” to begin the course. The contractor shall submit the Awareness Training Certificates of Completion to the COR prior to any on-base performance under this contract (Attachment D).

https://cs2.eis.af.mil/sites/10040/WPP/LMS/Installation%20Home.aspx?InstallationID=98&InstallationName=Cannon https://cs2.eis.af.mil/sites/10040/WPP/LMS/Installation%20Home.aspx?InstallationID=98&InstallationName=Cannon

Contract: Pending LATRINE AND SEPTIC SERVICE Attachment 1

4.7. HAZARDOUS MATERIALS (HM) HANDLING. HM must be approved prior to being brought on site by the contractor. The contractor may not bring HM onto CAFB or MAFR, nor use a HM, until the contractor receives all required authorizations.

4.7.1. The information on Cannon AFB & Melrose AFR Contractor Hazmat Approval Worksheet (Attachment C-4) and Safety Data Sheets (SDS) must be submitted to the CO prior to usage.

4.7.2. In the event environmental laws/regulations change during the term of this contract, the contractor is required to comply as such laws/regulations come into effect.

4.7.3. Notification of Environmental Spills. If the contractor spills or releases any substance contained in 40 CFR 302, Designation, Reportable Quantities, and Notification into the environment, the contractor or its agent shall immediately report the incident to CAFB Fire Department by calling (575)784-2578, if on CAFB, or MAFR. After reporting the spill or release the COR and CO must be notified as well. The contractor or its agent then has 24 hours maximum from the time of the spill or release to clean up the spill or release, and must act IAW with all federal, state and local laws and regulations when both cleaning and disposing of hazardous materials. The liability for the spill or release of such substances rests solely with the Contractor and its agent.

4.7.4. Permits. The contractor is responsible for obtaining all necessary permits to fulfill all requirements of this contract.

4.8. CONTINUATION OF ESSENTIAL DOD CONTRACTOR SERVICES DURING

CRISIS IAW DoDI 3020.41. This service is determined to be non-essential for performance during crisis according to DODI 3020.41, Operational Contract Support, paragraph 2.c. In the event of a crisis, the contractor will be notified by the CO of the need to discontinue services due to contingency, base closure or other causes. If notification to discontinue services is not received, the contractor shall be expected to continue performance in accordance with this PWS.

4.9. CONTRACTOR MANPOWER REPORTING REQUIREMENTS. The contractor shall report ALL contractor labor hours (including subcontractor labor hours) required for performance of services provided under this contract for the Air Force via a secure data collection site. The contractor is required to completely fill in all required data fields using the following web address: sam.gov. Reporting inputs will be for the labor executed during the period of performance during each Government fiscal year (FY), which runs 1 October through 30 September. While inputs may be reported any time during the FY, all data shall be reported no later than 31 October of each calendar year (Attachment D). Contractors may direct questions to the help desk at: sam.gov.

https://www.ecmra.mil/ https://www.ecmra.mil/

Contract: Pending LATRINE AND SEPTIC SERVICE Attachment 1

4.10. SAFETY REQUIREMENTS AND REPORTS. The contractor shall perform work in a safe manner as required by OSHA Safety and Health Requirements.

4.10.1. Mishap Notification. The contractor shall provide a verbal report to the CO as soon as possible of each occurrence of damage to Government property or a mishap resulting in death, injury, occupational disease, or adverse environmental impact (Attachment D).

4.10.2. Reporting. The contractor shall provide a copy of all required Accident Investigation Reports to the CO within 5 calendar days of each occurrence. The contractor shall report contractor personnel occupational injuries, illnesses, and other related activities in accordance with the Occupational Safety and Health Act (OSHA). The contractor shall maintain records as required by Federal, State, and local regulations (Attachment D).

4.10.3. Investigations. The contractor shall cooperate fully and assist Government personnel in any Government mishap investigation until released by the mishap investigation authority. Do not release mishap information outside official Government channels.

5. ATTACHMENTS

A. Estimated Workload Data B. List of Latrines and Holding/Septic Tanks Location B-1, CAFB Latrine Location Map (IP) B-2, MAFR Latrine Location Map B-3, Remote Site Latrine Location Map C. Forms/Data Requirements C-1, Work Order Sample C-2, 27 SOCES Form 103, Base Civil Engineering Work Clearance Request C-3, Corrective Action Report (CAR), Template C-4, CAFB & MAFR Contractor Hazmat Worksheet C-5, CAFB & MAFR Contractor Hazmat Worksheet Instructions D. Cannon Air Force Base & Melrose Air Force Range Civilian Contractor Environmental Guide E. MAFR Standard Operating Procedure (SOP) 13-212

Contract: Pending Solicitation: FA4855-XX-X-XXXX

LATRINE AND SEPTIC SERVICE

Performance Work Statement

Attachment A Estimated Workload Data

CLIN

NON-PERSONAL SERVICES: Provide all labor, tools, parts, material, equipment, transportation and services necessary to furnish and maintain portable chemical latrines and handwash stations, and pump domestic wastewater holding and septic tanks at Cannon AFB (CAFB) and Melrose Air Force Range (MAFR), New Mexico, in accordance with the Performance Work Statement (PWS).

Unit Qty

X001 Standard Latrine - CAFB (PWS 1.1.1, 1.1.2, 1.2, 1.4) EA 3 X002 Service Standard Latrine - CAFB (PWS 1.1.1, 1.3) EA 156 X003 Handicap Latrine - CAFB (PWS 1.1.1, 1.2, 1.4) EA 0 X004 Service Handicap Latrine - CAFB (PWS 1.1.1, 1.3) EA 0 X005 Hand Wash Station - CAFB (PWS 1.1.1, 1.2, 1.4) EA 0 X006 Service Hand Wash Station - CAFB (PWS 1.1.1, 1.3) EA 0 X007 Pump Septic Tank (Small, up to 2500 gallons) - CAFB (PWS 1.5, 1.5.1) EA 0 X008 Pump Septic Tank (Large, 2500-5000 gallons) - CAFB (PWS 1.5, 1.5.1) EA 0 X009 Pump Holding Tank (Small, up to 500 gallons) - CAFB (PWS 1.5, 1.5.1) EA 0 X010 Standard Latrine - CPEF (PWS 1.1.1, 1.2, 1.4) EA 200 X011 Service Standard Latrine - CPEF (PWS 1.1.1, 1.3) EA 220 X012 Hand Wash Station - CPEF (PWS 1.1.1, 1.2, 1.4) EA 25 X013 Service Hand Wash Station - CPEF (PWS 1.1.1, 1.2, 1.4) EA 125 X014 Pump Holding Tank (Small, up to 300 gallons) - CPEF (PWS 1.5, 1.5.1) EA 20

X015 Pump Holding Tank (Medium, 301-500 gallons) - CPEF (PWS 1.5, 1.5.1) EA 80

X016 Pump Holding Tank (Large, 501 gallons and above) - CPEF (PWS 1.5, 1.5.1) EA 50

X017 Emergency Septic Servicing - CAFB-MAFR PEFs (PWS 1.7) EA 1

X018 Standard Latrines - MAFR (PWS 1.1.1, 1.1.2, 1.2, 1.4) EA 12 X019 Service Standard Latrines - MAFR (PWS 1.1.1, 1.2) EA 312 X020 Pump Septic Tank (Small, up to 2500 gallons) - MAFR (PWS 1.5) EA 1 X021 Pump Septic Tank (Large, 2500-5000 gallons - MAFR (PWS 1.5) EA 1 X022 Standard Latrine - MPEF (PWS 1.1.1, 1.1.2, 1.2, 1.4) EA 6 X023 Service Standard Latrine - MPEF (PWS 1.1.1, 1.1.2, 1.3) EA 50 X024 Pump Holding Tank (Medium, 300-500 gallons) - MPEF (PWS 1.5, 1.5.1) EA 10 X025 Pump Holding Tank (Large, 501-1200 gallons) - MPEF) (PWS 1.5, 1.5.1) EA 10 X026 Standard Latrines - Remote Sites (1.1.1, 1.1.2, 1.2, 1.4) EA 7 X027 Service Standard Latrines - Remote Sites (PWS 1.1.1, 1.1.2, 1.3) EA 128 X028 Manifest (PWS 1.5.1) EA 0

1 March 2025 - 28 Feb 2026

FOR OFFICIAL USE ONLY

LATRINE SERVICE

Additional Note: This is an estimate of normal/planned operations, this does not include order for outtages, special events, or additional exercises.

LATRINE AND SEPTIC SERVICE

Performance Work Statement

Attachment A Estimated Workload Data

CLIN

NON-PERSONAL SERVICES: Provide all labor, tools, parts, material, equipment, transportation and services necessary to furnish and maintain portable chemical latrines and handwash stations, and pump domestic wastewater holding and septic tanks at Cannon AFB (CAFB) and Melrose Air Force Range (MAFR), New Mexico, in accordance with the Performance Work Statement (PWS).

Unit Qty

1001 Standard Latrine - CAFB (PWS 1.1.1, 1.1.2, 1.2, 1.4) EA 3 1002 Service Standard Latrine - CAFB (PWS 1.1.1, 1.3) EA 156 1003 Handicap Latrine - CAFB (PWS 1.1.1, 1.2, 1.4) EA 0 1004 Service Handicap Latrine - CAFB (PWS 1.1.1, 1.3) EA 0 1005 Hand Wash Station - CAFB (PWS 1.1.1, 1.2, 1.4) EA 0 1006 Service Hand Wash Station - CAFB (PWS 1.1.1, 1.3) EA 0 1007 Pump Septic Tank (Small, up to 2500 gallons) - CAFB (PWS 1.5, 1.5.1) EA 0 1008 Pump Septic Tank (Large, 2500-5000 gallons) - CAFB (PWS 1.5, 1.5.1) EA 0 1009 Pump Holding Tank (Small, up to 500 gallons) - CAFB (PWS 1.5, 1.5.1) EA 0 1010 Standard Latrine - CPEF (PWS 1.1.1, 1.2, 1.4) EA 200 1011 Service Standard Latrine - CPEF (PWS 1.1.1, 1.3) EA 220 1012 Hand Wash Station - CPEF (PWS 1.1.1, 1.2, 1.4) EA 25 1013 Service Hand Wash Station - CPEF (PWS 1.1.1, 1.2, 1.4) EA 125 1014 Pump Holding Tank (Small, up to 300 gallons) - CPEF (PWS 1.5, 1.5.1) EA 20

1015 Pump Holding Tank (Medium, 301-500 gallons) - CPEF (PWS 1.5, 1.5.1) EA 80

1016 Pump Holding Tank (Large, 501 gallons and above) - CPEF (PWS 1.5, 1.5.1) EA 50

1017 Emergency Septic Servicing - CAFB-MAFR PEFs (PWS 1.7) EA 1

1018 Standard Latrines - MAFR (PWS 1.1.1, 1.1.2, 1.2, 1.4) EA 12 1019 Service Standard Latrines - MAFR (PWS 1.1.1, 1.2) EA 312 1020 Pump Septic Tank (Small, up to 2500 gallons) - MAFR (PWS 1.5) EA 1 1021 Pump Septic Tank (Large, 2500-5000 gallons - MAFR (PWS 1.5) EA 1 1022 Standard Latrine - MPEF (PWS 1.1.1, 1.1.2, 1.2, 1.4) EA 6 1023 Service Standard Latrine - MPEF (PWS 1.1.1, 1.1.2, 1.3) EA 50 1024 Pump Holding Tank (Medium, 300-500 gallons) - MPEF (PWS 1.5, 1.5.1) EA 10 1025 Pump Holding Tank (Large, 501-1200 gallons) - MPEF) (PWS 1.5, 1.5.1) EA 10 1026 Standard Latrines - Remote Sites (1.1.1, 1.1.2, 1.2, 1.4) EA 7 1027 Service Standard Latrines - Remote Sites (PWS 1.1.1, 1.1.2, 1.3) EA 128 1028 Manifest (PWS 1.5.1) EA 0

1 March 2026 - 28 Feb 2027

FOR OFFICIAL USE ONLY

LATRINE SERVICE

Additional Note: This is an estimate of normal/planned operations, this does not include order for outtages, special

LATRINE AND SEPTIC SERVICE

Performance Work Statement

Attachment A Estimated Workload Data

CLIN

NON-PERSONAL SERVICES: Provide all labor, tools, parts, material, equipment, transportation and services necessary to furnish and maintain portable chemical latrines and handwash stations, and pump domestic wastewater holding and septic tanks at Cannon AFB (CAFB) and Melrose Air Force Range (MAFR), New Mexico, in accordance with the Performance Work Statement (PWS).

Unit Qty

2001 Standard Latrine - CAFB (PWS 1.1.1, 1.1.2, 1.2, 1.4) EA 3 2002 Service Standard Latrine - CAFB (PWS 1.1.1, 1.3) EA 156 2003 Handicap Latrine - CAFB (PWS 1.1.1, 1.2, 1.4) EA 0 2004 Service Handicap Latrine - CAFB (PWS 1.1.1, 1.3) EA 0 2005 Hand Wash Station - CAFB (PWS 1.1.1, 1.2, 1.4) EA 0 2006 Service Hand Wash Station - CAFB (PWS 1.1.1, 1.3) EA 0 2007 Pump Septic Tank (Small, up to 2500 gallons) - CAFB (PWS 1.5, 1.5.1) EA 0 2008 Pump Septic Tank (Large, 2500-5000 gallons) - CAFB (PWS 1.5, 1.5.1) EA 0 2009 Pump Holding Tank (Small, up to 500 gallons) - CAFB (PWS 1.5, 1.5.1) EA 0 2010 Standard Latrine - CPEF (PWS 1.1.1, 1.2, 1.4) EA 200 2011 Service Standard Latrine - CPEF (PWS 1.1.1, 1.3) EA 220 2012 Hand Wash Station - CPEF (PWS 1.1.1, 1.2, 1.4) EA 25 2013 Service Hand Wash Station - CPEF (PWS 1.1.1, 1.2, 1.4) EA 125 2014 Pump Holding Tank (Small, up to 300 gallons) - CPEF (PWS 1.5, 1.5.1) EA 20

2015 Pump Holding Tank (Medium, 301-500 gallons) - CPEF (PWS 1.5, 1.5.1) EA 80

2016 Pump Holding Tank (Large, 501 gallons and above) - CPEF (PWS 1.5, 1.5.1) EA 50

2017 Emergency Septic Servicing - CAFB-MAFR PEFs (PWS 1.7) EA 1

2018 Standard Latrines - MAFR (PWS 1.1.1, 1.1.2, 1.2, 1.4) EA 12 2019 Service Standard Latrines - MAFR (PWS 1.1.1, 1.2) EA 312 2020 Pump Septic Tank (Small, up to 2500 gallons) - MAFR (PWS 1.5) EA 1 2021 Pump Septic Tank (Large, 2500-5000 gallons - MAFR (PWS 1.5) EA 1 2022 Standard Latrine - MPEF (PWS 1.1.1, 1.1.2, 1.2, 1.4) EA 6 2023 Service Standard Latrine - MPEF (PWS 1.1.1, 1.1.2, 1.3) EA 50 2024 Pump Holding Tank (Medium, 300-500 gallons) - MPEF (PWS 1.5, 1.5.1) EA 10 2025 Pump Holding Tank (Large, 501-1200 gallons) - MPEF) (PWS 1.5, 1.5.1) EA 10 2026 Standard Latrines - Remote Sites (1.1.1, 1.1.2, 1.2, 1.4) EA 7 2027 Service Standard Latrines - Remote Sites (PWS 1.1.1, 1.1.2, 1.3) EA 128 2028 Manifest (PWS 1.5.1) EA 0

1 March 2027 - 28 Feb 2028

FOR OFFICIAL USE ONLY

LATRINE SERVICE

Additional Note: This is an estimate of normal/planned operations, this does not include order for outtages, special

LATRINE AND SEPTIC SERVICE

Performance Work Statement

CLIN

NON-PERSONAL SERVICES: Provide all labor, tools, parts, material, equipment, transportation and services necessary to furnish and maintain portable chemical latrines and handwash stations, and pump domestic wastewater holding and septic tanks at Cannon AFB (CAFB) and Melrose Air Force Range (MAFR), New Mexico, in accordance with the Performance Work Statement (PWS).

Unit Qty

3001 Standard Latrine - CAFB (PWS 1.1.1, 1.1.2, 1.2, 1.4) EA 3 3002 Service Standard Latrine - CAFB (PWS 1.1.1, 1.3) EA 156 3003 Handicap Latrine - CAFB (PWS 1.1.1, 1.2, 1.4) EA 0 3004 Service Handicap Latrine - CAFB (PWS 1.1.1, 1.3) EA 0 3005 Hand Wash Station - CAFB (PWS 1.1.1, 1.2, 1.4) EA 0 3006 Service Hand Wash Station - CAFB (PWS 1.1.1, 1.3) EA 0 3007 Pump Septic Tank (Small, up to 2500 gallons) - CAFB (PWS 1.5, 1.5.1) EA 0 3008 Pump Septic Tank (Large, 2500-5000 gallons) - CAFB (PWS 1.5, 1.5.1) EA 0 3009 Pump Holding Tank (Small, up to 500 gallons) - CAFB (PWS 1.5, 1.5.1) EA 0 3010 Standard Latrine - CPEF (PWS 1.1.1, 1.2, 1.4) EA 200 3011 Service Standard Latrine - CPEF (PWS 1.1.1, 1.3) EA 220 3012 Hand Wash Station - CPEF (PWS 1.1.1, 1.2, 1.4) EA 25 3013 Service Hand Wash Station - CPEF (PWS 1.1.1, 1.2, 1.4) EA 125 3014 Pump Holding Tank (Small, up to 300 gallons) - CPEF (PWS 1.5, 1.5.1) EA 20

3015 Pump Holding Tank (Medium, 301-500 gallons) - CPEF (PWS 1.5, 1.5.1) EA 80

3016 Pump Holding Tank (Large, 501 gallons and above) - CPEF (PWS 1.5, 1.5.1) EA 50

3017 Emergency Septic Servicing - CAFB-MAFR PEFs (PWS 1.7) EA 1

3018 Standard Latrines - MAFR (PWS 1.1.1, 1.1.2, 1.2, 1.4) EA 12 3019 Service Standard Latrines - MAFR (PWS 1.1.1, 1.2) EA 312 3020 Pump Septic Tank (Small, up to 2500 gallons) - MAFR (PWS 1.5) EA 1 3021 Pump Septic Tank (Large, 2500-5000 gallons - MAFR (PWS 1.5) EA 1 3022 Standard Latrine - MPEF (PWS 1.1.1, 1.1.2, 1.2, 1.4) EA 6 3023 Service Standard Latrine - MPEF (PWS 1.1.1, 1.1.2, 1.3) EA 50 3024 Pump Holding Tank (Medium, 300-500 gallons) - MPEF (PWS 1.5, 1.5.1) EA 10 3025 Pump Holding Tank (Large, 501-1200 gallons) - MPEF) (PWS 1.5, 1.5.1) EA 10 3026 Standard Latrines - Remote Sites (1.1.1, 1.1.2, 1.2, 1.4) EA 7 3027 Service Standard Latrines - Remote Sites (PWS 1.1.1, 1.1.2, 1.3) EA 128 3028 Manifest (PWS 1.5.1) EA 0

1 March 2028 - 29 Feb 2029

FOR OFFICIAL USE ONLY

LATRINE SERVICE

Additional Note: This is an estimate of normal/planned operations, this does not include orders for outtages, special

LATRINE AND SEPTIC SERVICE

Performance Work Statement

Attachment A Estimated Workload Data

CLIN

NON-PERSONAL SERVICES: Provide all labor, tools, parts, material, equipment, transportation and services necessary to furnish and maintain portable chemical latrines and handwash stations, and pump domestic wastewater holding and septic tanks at Cannon AFB (CAFB) and Melrose Air Force Range (MAFR), New Mexico, in accordance with the Performance Work Statement (PWS).

Unit Qty

4001 Standard Latrine - CAFB (PWS 1.1.1, 1.1.2, 1.2, 1.4) EA 3 4002 Service Standard Latrine - CAFB (PWS 1.1.1, 1.3) EA 156 4003 Handicap Latrine - CAFB (PWS 1.1.1, 1.2, 1.4) EA 0 4004 Service Handicap Latrine - CAFB (PWS 1.1.1, 1.3) EA 0 4005 Hand Wash Station - CAFB (PWS 1.1.1, 1.2, 1.4) EA 0 4006 Service Hand Wash Station - CAFB (PWS 1.1.1, 1.3) EA 0 4007 Pump Septic Tank (Small, up to 2500 gallons) - CAFB (PWS 1.5, 1.5.1) EA 0 4008 Pump Septic Tank (Large, 2500-5000 gallons) - CAFB (PWS 1.5, 1.5.1) EA 0 4009 Pump Holding Tank (Small, up to 500 gallons) - CAFB (PWS 1.5, 1.5.1) EA 0 4010 Standard Latrine - CPEF (PWS 1.1.1, 1.2, 1.4) EA 200 4011 Service Standard Latrine - CPEF (PWS 1.1.1, 1.3) EA 220 4012 Hand Wash Station - CPEF (PWS 1.1.1, 1.2, 1.4) EA 25 4013 Service Hand Wash Station - CPEF (PWS 1.1.1, 1.2, 1.4) EA 125 4014 Pump Holding Tank (Small, up to 300 gallons) - CPEF (PWS 1.5, 1.5.1) EA 20

4015 Pump Holding Tank (Medium, 301-500 gallons) - CPEF (PWS 1.5, 1.5.1) EA 80

4016 Pump Holding Tank (Large, 501 gallons and above) - CPEF (PWS 1.5, 1.5.1) EA 50

4017 Emergency Septic Servicing - CAFB-MAFR PEFs (PWS 1.7) EA 1

4018 Standard Latrines - MAFR (PWS 1.1.1, 1.1.2, 1.2, 1.4) EA 12 4019 Service Standard Latrines - MAFR (PWS 1.1.1, 1.2) EA 312 4020 Pump Septic Tank (Small, up to 2500 gallons) - MAFR (PWS 1.5) EA 1 4021 Pump Septic Tank (Large, 2500-5000 gallons - MAFR (PWS 1.5) EA 1 4022 Standard Latrine - MPEF (PWS 1.1.1, 1.1.2, 1.2, 1.4) EA 6 4023 Service Standard Latrine - MPEF (PWS 1.1.1, 1.1.2, 1.3) EA 50 4024 Pump Holding Tank (Medium, 300-500 gallons) - MPEF (PWS 1.5, 1.5.1) EA 10 4025 Pump Holding Tank (Large, 501-1200 gallons) - MPEF) (PWS 1.5, 1.5.1) EA 10 4026 Standard Latrines - Remote Sites (1.1.1, 1.1.2, 1.2, 1.4) EA 7 4027 Service Standard Latrines - Remote Sites (PWS 1.1.1, 1.1.2, 1.3) EA 128 4028 Manifest (PWS 1.5.1) EA 0

1 March 2029 - 29 Feb 2030

FOR OFFICIAL USE ONLY

LATRINE SERVICE

Additional Note: This is an estimate of normal/planned operations, this does not include order for outtages, special

Contract: FA4855-xx-x-xxxx LATRINE AND SEPTIC SERVICE Performance Work Statement

Attachment B 3 December 2024

Base/ Range

Specific Locations/Descriptors of Static Chemical Latrines Type

Motorcycle Training (Fenced-in Area, W of Bldg 1820) Standard Softball Fields Standard Portales Gate Vehicle Inspection Area (near Bldg 2260) Standard N. Krider Road Gate 1 (PJ-01) Standard Range 7 (PJ-02) Standard TA-2A Jockey (PJ-03) Standard Range 5 (PJ-04) Standard Sundale Valley Road, East Wreck Yard (PJ-05) Standard TA-3F (PJ-06) Standard TA-3B Embassy (PJ-07) Standard TA-3B (PJ-08) Standard TA-4B (PJ-09) Standard TA-4A (PJ-10) Standard S. Krider Road Gate 6 (PJ-11) Standard Sprint HLZ (PJ-12) Standard Santa Rosa, Guadalupe County, New Mexico Standard Jordan, Quay County, New Mexico Standard McAlister, Quay County, New Mexico Standard Yeso, De Baca County, New Mexico Standard Ft Sumner, De Baca County, New Mexico Standard Dunlap, De Baca County, New Mexico Standard Elida, Chaves County, New Mexico Standard

ATTACHMENT B - LOCATION OF LATRINES & HOLDING/SEPTIC TANKS

Ca nn on

AF

B M el ro se

AF

R Re m ot e

Si te s

Contract: FA4855-xx-x-xxxx LATRINE AND SEPTIC SERVICE Performance Work Statement

Attachment B 3 December 2024

Bldg No.

Locations of Domestic Wastewater Holding / Septic Tanks Size

(Gals) 21398 Golf Course Restroom, adjacent to #9 Tee Box 750 22315 Combat Arms Training Maintenance (CATM) Facility, between Bldgs 2314 and 2315 2,000 22318 Combat Arms Training Maintenance (CATM) Facility, Trap and Skeet Range 1,500 22320 Communications Sq Facility, behind Bldg 2320 1,250 22327 Recycling Warehouse, located to the right of Bldg 2327 1,250 22371 Military Working Dog Kennel, located to the right of Bldg 2371, near corner of fencing 1,000 22372 Military Working Dog Veterinary Facility, located near Septic Tank 22371, closest to Bldg 2372 1,000 22379 UAV Facility, located to the left of Bldg 2380 500 2259 Portales Gate, between Bldg 2250 and Bldg 2260 1,000

29981 Doc Stewart Park Pavilion 1,500 29982 Doc Stewart Park Recreation Area 2,000 CPEF Cannon AFB - Latrine Trailer, adjacent to Bldg 2347 (Holding) 1,200 CPEF Cannon AFB - Shower Trailer, adjacent to Bldg 2347 (Holding) 1,200 CPEF Cannon AFB - Between Bldgs 2346 and 2347 (Holding) 300 CPEF Cannon AFB - Mobile Trailer (Holding) 450 CPEF Cannon AFB - Mobile Trailer (Holding) 1,150

22348 CPEF (Septic) 1,500 1016 2000 1097 1000 1101 1000 3126 3000 3151 1500 3155 2000 3157 1500 3163 1500 3202 1250 8311 1646 MAFR Melrose AFR - Fire Dept Trailer (Septic) 5,000

C A

FB

C

PE

F

M A

FR

GECCO

Spirit South

Sunda le V a lley Rd

Kr ide r R d

TOWER

OP-3

OP-1

Lynx

Sh ad ow

Sti ng er

Ha dri an

La nc e

Pike

U ta h

O m a ha

Go ld

Ju no Sw ord

Spirit Center

Spirit North

Chariot

Jockey

Ga tlin

M PEF FO B

RSC

DEMO 2

N

E

TA-4D

TA-4E

SW M a neuver Area

Entry Control Building

Ga ra n d

Lin eb a c ke r

DEMO 1

BREACH SITE

Stum pnec k

India n Hea d

Denb y Rd

N M a neuver Area RESTRICTED

RT

E.

R em ing ton

W ell Roa d

W ilderness

Ha wkeye

AIE Site

TA-1B

Trapper

Tra ppe r

TA-2D

OP-2

M esa

S M a neuver Area

5a 5c abc

11b

TA-1A

N M a neuver Area

TA-2A

NE M a neuver Area

TA-2C

TA-3A

TA-3B

TA-3C

TA-3D

TA-3E

TA-3F

SE M aneuver Area S M a neuver Area RESTRICTED

TA-4A

SW M a neuver Area

NW M a neuver Area

TA-4B

Bob c a t LZ 03R/21L

Red Horse LZ

Bob c a t LZ 03L/21R

Springfield DZ

Bob c a t DZ

M esa Circ ula r DZ

Eastwood / Elliot DZ

Stoudenm ire DZ

Colt DZ

Red Horse DZ

E Dad D

Argel W est DZ

Ca lispell DZ

Joc key Circ ula r DZ

M esa W est DZ

Yeti HLZ V iper HLZ

Ferrari HLZ Sa leen HLZ

Bronco HLZ

Corvette HLZ

Gotha m HLZ

Lotus HLZ

Bugatti HLZ

Pa ga ni HLZ

Sprint HLZ

Nissan HLZ

Explorer HLZ

La m b orghini HLZ

Na va jo HLZ

Exxon HLZ

Nitro HLZ

Neon HLZ

W ilderness HLZ

Newport HLZ

W rangler HLZ

Na viga tor HLZ

W a rrior HLZ

Stanza HLZ

Nom a d HLZ

Esc a pe HLZ

W a goneer HLZ

Silvera do HLZ

W inneb a go HLZ

W estfield HLZ

Nash HLZ

Sierra HLZ

Sna ke Eyes HLZ

Expedition HLZ

FARP

FARP

M7

M6

M5 M4 M3

M2

M 1

M

MP-4

P-3

M P-1

M -1

C-7C-8

C-1

A-2 A-3

A-4

A-5

A-6

A-7

A-8

C-10

C-13

C-23

B-10

B-11

B-12

B-13

B-14

B-15

B-16

C-14

C-15

C-16

C-17

C-18

C-20

C-21

C-31

E-2

E-1

P-1

P-6

P-4

P-2

P-3

P-5

P-7

P-8

P-9

P-17

P-16

P-14

P-12

P-32

P-34P-33 P-36 P-37 P-38

P-39

P-40

P-41

P-42

P-43

P-11

P-13P-15

P-10

22212019181716151413

11100908070605040302

01385

0 1280

1285 1305

0 1280

103°40'0"W

103°40'0"W

103°41'0"W

103°41'0"W

103°42'0"W

103°42'0"W

103°43'0"W

103°43'0"W

103°44'0"W

103°44'0"W

103°45'0"W

103°45'0"W

103°46'0"W

103°46'0"W

103°47'0"W

103°47'0"W

103°48'0"W

103°48'0"W

103°49'0"W

103°49'0"W

103°50'0"W

103°50'0"W

103°51'0"W

103°51'0"W

103°52'0"W

103°52'0"W

103°53'0"W

103°53'0"W103°54'0"W

34°23'0"N 34°23'0"N

34°22'0"N 34°22'0"N

34°21'0"N 34°21'0"N

34°20'0"N 34°20'0"N

34°19'0"N 34°19'0"N

34°18'0"N 34°18'0"N

34°17'0"N 34°17'0"N

34°16'0"N 34°16'0"N

34°15'0"N 34°15'0"N

34°14'0"N 34°14'0"N

34° 133

34°13'0"N

SAMPLE 1,000 METER GRID SQUARE

12 13 x SAMPLE

POINT

100,000 M. SQUARE IDENTIFICATION

3800FU

FT

GRID ZONE DESIGNATION

13S

100 METER REFERENCE

1.

2.

Read large numbers labeling the VERTICAL grid line left of point and estimate tenths (100 meters) from grid line to

Read large numbers labeling the HORIZONTAL grid line below point and estimate tenths (100 meters) from grid line to point. 12 3 point. 94 6

WHEN REPORTING ACROSS A 100,000 METER LINE, PREFIX

THE 100,000 METER SQUARE IDENTIFICATION IN WHICH THE

WHEN REPORTING OUTSIDE THE GRID ZONE DESIGNATION

Example: 123946

POINT LIES.

Example: FT123946

AREA. PREFIX THE GRID ZONE DESIGNATION.

Example: 13SFT123946

NEW MEXICO 1:25,000 MELROSE AIR FORCE RANGE WGS 84

NAV IGATIO N M AP

FU

FT FU

FT

Meters Feet

CONVERSION GRAPH

(1 meter = 3.28 feet)

NOTES

THIS M AP DO ES NO T M EET NGA TO PO GRAPHICAL LINE M AP PRO DU CTIO N SPECIFICATIO NS

THE M ILITARY RESERV ATIO N BO U NDRY IS AU THO RITATIV E

THERE ARE HISTO RICAL SITES W ITHIN THE M ILITARY RESERV ATIO N BO U NDRY

A LANE O N THIS M AP IS CO NSIDERED TO BE AT LEAST 2.5 M ETERS (8FEET) W IDE

RO AD CLASSIFICATIO N SHO U LD BE REFERRED TO W ITH CAU TIO N

TRAILS RU N ALO NG THE M AJO RITY O F THE FENCE LINE W ITHIN THE M ILITARY RESERV ATIO N BO U NDRY

TR

UE

N

OR

TH

GN

GRID CONVERGENCE

0° 41' (12 MILS)

FOR CENTER OF SHEET

GR

ID

NO

RT

H

Ù

G-M ANGLE

6.2° (110 MILS)

MA

GN

ET

IC

NO

RT

H

TO CONVERT A

MAGNETIC AZIMUTH

TO A GRID AZIMUTH

ADD G-M ANGLE

TO CONVERT A

GRID AZIMUTH TO A

MAGNETIC AZIMUTH

SUBTRACT G-M ANGLE

RO U TES ALPHA, BRAV O AND CHARLIE ARE U SED AS FIREBREAKS

Argel W est 13SFU 13425 02568N 34-21.495 W 103-45.996 Bob c a t 13SFT18417 92472 N 34-16.000 W 103-42.823 Browning 13SFT 04667 99976 N 34-20.148 W 103-51.729 Ca lispell 13SFT 07794 89526 N 34-14.475 W 103-49.767 Colt Circ ular 13SFT 04667 99976 N 34-20.148 W 103-51.728 Eastwood 13SFT 19128 92097 N 34-15.792 W 103-42.363 El Dora do 13SFT 19128 92097 N 34-15.792 W 103-42.363 Elliott 13SFT 19128 92097 N 34-15.792 W 103-42.363 Joc key Circ ular13SFT 13361 98421 N 34-19.252 W 103-46.070 M esa Circ ular 13SFT 07570 94984 N 34-17.430 W 103-49.872 M esa W est 13SFT 07924 94353 N 34-17.086 W 103-49.646 Red Horse 13SFT 07349 98037 N 34-19.083 W 103-49.993 Remington 13SFT 04666 99976 N 34-20.148 W 103-51.729 Springfield 13SFT 13514 92337 N 34-15.960 W 103-46.019 Stoudenmire 13SFT 08502 90035 N 34-14.746 W 103-49.302

DROP ZONES (Center Points) Bronc o 13SFT 15060 90537 N 34-14.976 W 103-45.025 Bugatti 13SFT 14654 95930 N 34-17.895 W 103-45.247 Corvette 13SFT 13099 98263 N 34-19.168 W 103-46.242 Esc ape 13SFT 14099 95982 N 34-17.928 W 103-45.609 Expedition 13SFT 16821 98325 N 34-19.177 W 103-43.815 Explorer 13SFT 18872 92199 N 34-15.849 W 103-42.529 Exxon 13SFT 17869 92143 N 34-15.826 W 103-43.183 Ferrari 13SFT 14916 91882 N 34-17.704 W 103-45.109 Gotha m 13SFT 15538 93064 N 34-16.339 W 103-44.694 La m b orghini 13SFT 14301 95123 N 34-17.461 W 103-45.484 Lotus 13SFT 15484 97658 N 34-18.825 W 103-44.692

M PEF 13SFT 07107 99183 N 34-19.704 W 103-50.142

Nash 13SFT 07674 97887 N 34-18.999 W 103-49.782 Na va jo 13SFT 12327 97785 N 34-18.915 W 103-46.750 Na vigator 13SFU 14809 02047N 34-21.204 W 103-45.097

HELICOPTER LANDING ZONES (Center Points)

Neon 13SFU 09556 01833N 34-21.122 W 103-48.525 Newport 13SFT 13409 98267 N 34-19.168 W 103-46.041 Nissan 13SFU 13034 02343N 34-21.376 W 103-46.253 Nitro 13SFT 09557 99974 N 34-20.117 W 103-48.539 Nom a d 13SFU 09680 03904N 34-22.242 W 103-48.429 Pa gani 13SFT 15524 96868 N 34-18.397 W 103-44.673 Sa leen 13SFT 13464 92071 N 34-15.816 W 103-46.053 Sierra 13SFT 09301 90675 N 34-15.087 W 103-48.776 Silvera do 13SFT 11881 89960 N 34-14.684 W 103-47.101 Sna ke Eyes 13SFT 11856 95521 N 34-17.693 W 103-47.074 Sprint 13SFT 06219 87503 N 34-13.391 W 103-50.808 Stanza 13SFT 14972 90024 N 34-14.699 W 103-45.087 V iper 13SFT 14494 89432 N 34-14.382 W 103-45.403 W a goneer 13SFT 07313 95387 N 34-17.649 W 103-50.036 W arrior 13SFT 07086 95129 N 34-17.511 W 103-50.186 W estfield 13SFT 09131 94485 N 34-17.150 W 103-48.858 W ilderness 13SFT 02047 99058 N 34-19.667 W 103-53.443 W inneb a go 13SFT 06330 91136 N 34-15.355 W 103-50.709 W rangler 13SFT 05342 97402 N 34-18.751 W 103-51.307 Yeti 13SFT 07920 89294 N 34-14.349 W 103-49.687

Red Horse 13SFT 07251 98074 N 34-19.103 W 103-50.057 Bob c a t 03L/21R13SFT 18442 92541 N 34-16.036 W 103-42.741 Bob c a t 03R/21L13SFT 18451 92615 N 34-16.077 W 103-42.800

LANDING…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .