Attachment_1_-_Hazardous_Material_Survey_Reports.pdf

PDF 820 KB Posted

Attached to
PRWI DEMO OF NON-HISTORIC BUILDINGS
Solicitation number
140P3021Q0035
Issued by

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ASBESTOS AND LEAD-BASED PAINT

SURVEY REPORT

Prince William Forest

RV Campground

16058 Dumfries Rd.

Dumfries, VA 22025

PREPARED FOR:

Prince William Forest

National Park Service

18100 Park Headquarters Road

Triangle, VA 22172

PREPARED BY:

Jordan Environmental Services, LLC

4735 Great Heron Circle

Fairfax, VA 22033

Project # - JES 2019 – 183ASL April 24, 2019

4735 Great Heron Circle, Fairfax, VA 22033 / (571) 405-0985 / bradford.jordan@jordan-environmental.com

TABLE OF CONTENTS

1.0 – Cover Letter ……..………………………………….………...…………………..Page 1

2.0 - Survey Report……………..……………………..………………………………..Page 2

3.0 - Asbestos Sample Results ………………....………………….………...………Page 3

4.0 - XRF Lead Report ………..…………….………………………………………….Page 4

5.0 - License ………………………………….………………………………………….Page 5

4735 Great Heron Circle, Fairfax, VA 22033 / (571) 405-0985 / bradford.jordan@jordan-environmental.com

National Park Service

ATTN: K. Scott Shea

B&U Supervisor

RE: Prince William Forest RV Campground

JES Project Number: JES-2019-187ASL

Dear Mr. Shea:

Jordan Environmental Services (JES) is pleased to submit this asbestos and lead-based paint survey report for the above referenced address. An asbestos and lead-based-paint survey was recently conducted at the commercial property for the Prince William Forest portion of the National Park Service. Mr. Vincent White

(Virginia Asbestos Inspector License Number 3303002292) conducted the fieldwork on April 10, 2019.

JES appreciates the opportunity to conduct this monitoring service. If you have any questions concerning this report, please contact me at (571) 405-0985.

Sincerely, JORDAN ENVIRONMENTAL SERVICES

Bradford Jordan

Chief Operating Officer

4735 Great Heron Circle, Fairfax, VA 22033 / (571) 405-0985 / bradford.jordan@jordan-environmental.com

National Park Service

ATTN: K. Scott Shea

B&U Supervisor

RE: Prince William Forest RV Campground

JES Project Number: JES-2019-187ASL

Dear Mr. Shea:

Jordan Environmental Services, (JES) has completed the survey for suspect asbestos-containing materials

(ACM) and lead-based paint (LBP) at the above referenced address. Mr. Vincent White (Virginia Asbestos

Inspector License Number 3303002292), conducted the survey April 10, 2019.

Fifteen samples (15) of suspect ACM material was taken from different areas at the above referenced address.

JES pulled samples of building materials. Samples were taken to determine if the material contained asbestos.

The samples were delivered to Amerisci Laboratory, located in Midlothian, Virginia, where they were analyzed for the presence of asbestos. By EPA and the Commonwealth of Virginia standards a sample collected from a multi-sample group is considered positive for asbestos if that sample contains asbestos in an amount greater than one percent (>1%). The samples were not determined to contain asbestos.

If you have any questions or concerning this report, please contact me at (571) 405-0985.

Respectfully Submitted, 4735 Great Heron Circle, Fairfax, VA 22033 / (571) 405-0985 / bradford.jordan@jordan-environmental.com

ASBESTOS INSPECTION

A Virginia Licensed asbestos inspector conducted a visual inspection/sampling survey which included the collecting of at least one but not more than three bulk samples, from each homogenous material to determine the presence of suspect asbestos-containing building materials (ACM). Suspect ACM was evaluated according to whether the materials were damaged/poor, damaged/fair or non-damaged/good condition during the time the inspection was conducted. The project was conducted in accordance with the Environmental Protection

Agency’s (EPA) rules and regulations.

The samples that are determined to be positive for asbestos would be noted in the sample summary sheet below.

However, no samples were found to be positive for asbestos. The samples summary sheets also distinguishes the NESHAP categories and the condition of each homogenous area sampled in order to determine if materials are regulated or non-regulated asbestos containing material (ACM).

Homogeneous materials are defined as being uniformed in texture, color and appearing identical in every other aspect.

LABORATORY METHODOLOGY:

Method of Analysis

Analysis was performed by using the bulk sample for visual observation and slide preparation(s) for microscopic examination and identification. JES collected fifteen (15) samples with fifteen (15) different homogeneous suspect materials. The samples are mounted on slides and then analyzed for asbestos that could contain chrysotile, amosite, crocidolite, anthophyllite, and actinolite/tremolite, fibrous non-asbestos constituents (mineral wool, paper, etc.) and non-fibrous constituents. Suspected asbestos samples were identified by PLM analyses.

This analytical method used by the laboratory is EPA Method 600/R-93/116 and EPA/600/M4-82/020

Polarized Light Microscopy (PLM) with Dispersion Staining.

4735 Great Heron Circle, Fairfax, VA 22033 / (571) 405-0985 / bradford.jordan@jordan-environmental.com

Asbestos Containing Material Defined

A material is considered by the EPA and the State of Virginia to be asbestos-containing if at least one sample collected from a multi-sample group contains asbestos in an amount greater than one percent (>1%).

According to NESHAP (40 CFR subpart M, part 61) asbestos regulations, materials found to contain asbestos fibers may be categorized as follows:

Regulated Asbestos-Containing Material (RACM):

(a) Friable asbestos material, which is a material when dry can be crumbled, pulverized or reduced to a powder by hand pressure.

(b) Category I nonfriable ACM that has become friable,

(c) Category I nonfriable ACM that will be or has been subjected to sanding, grinding, cutting, or abrading, or

(d) Category II nonfriable ACM that has a high probability of becoming or has become crumbled, pulverized, or reduced to powder by the forces expected to act on the material in the course of demolition or renovation operations regulated by this subpart.

Category I Nonfriable Asbestos-Containing Material (ACM):

Asbestos-containing packing’s, gaskets, resilient floor covering, and asphalt roofing products (built-up roofing, asphalt containing single ply membrane systems; asphalt shingles; asphalt containing underlayment felts; asphalt containing roof coatings and mastics; and asphalt containing base flashing and ACM roofing products that use other bituminous or resinous binders such as coal tars or pitches) containing more than 1 percent asbestos as determined using the methods specified in appendix E, subpart E, 40 CFR part 763, section 1, Polarized Light Microscopy.

Category II Nonfriable Asbestos-Containing Material (ACM):

Any material, excluding Category I nonfriable ACM, containing more than 1 percent asbestos as determined using the methods specified in appendix E, subpart E, 40 CFR part 763, section 1, Polarized

Light Microscopy that, when dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure.

Poor Condition means - The binding of the material is losing its integrity as indicated by peeling, cracking, or crumbling of the material.

Fair Condition - The surface crumbling blistered, water-stained, gouged marred or other wised abraded over less than one tenth of the surface if the damage is evenly distributed (one quarter if the damage is localized).

Good Condition means - The material is in intact and the binding of the material is not losing its integrity.

4735 Great Heron Circle, Fairfax, VA 22033 / (571) 405-0985 / bradford.jordan@jordan-environmental.com

Suspected Asbestos Containing Materials Sampled:

Sample

Group #

Sample #’s Material Location Asbestos

Containing?

YES/NO

Asbestos

Type

Quantity

1 1 Ceiling

Material

Foyer NO N/A N/A

1 2 Ceiling

Material

Kitchen NO N/A N/A

1 3 Ceiling

Material

Living Room NO N/A N/A

1 4 Ceiling

Material

Hall NO N/A N/A

1 5 Ceiling

Material

Bedroom 1 NO N/A N/A

1 6 Ceiling

Material

Master

Bedroom

NO N/A N/A

1 7 Ceiling

Material

Master

Bedroom

Bathroom

NO N/A N/A

1 8 Ceiling Joint

Compound

Dine Room NO N/A N/A

1 9 Ceiling Joint

Compound

Bathroom NO N/A N/A

1 10 Ceiling

Drywall

Dine Room NO N/A N/A

1 11 Ceiling

Drywall

Bathroom NO N/A N/A

1 12 Resilient

Flooring

Foyer NO N/A N/A

1 13 Resilient

Flooring

Kitchen NO N/A N/A

1 14 Resilient

Flooring

Master

Bathroom

NO N/A N/A

1 15 Resilient

Flooring

Hall

Bathroom

NO N/A N/A

*Note all material quantities are estimates, contractor needs to measure to verify.

4735 Great Heron Circle, Fairfax, VA 22033 / (571) 405-0985 / bradford.jordan@jordan-environmental.com

In accordance with your request, Jordan Environmental Services (JES) also performed a lead-based paint

(LBP) survey using a portable X-Ray Fluorescence (XRF) meter on April 10, 2019. The XRF testing was conducted in accordance with methodologies specified in 40 CFR 745.227, the Housing and Urban

Development (HUD) Chapter 7 Guidelines. The lead sampling was conducted by JES’s certified lead

Inspector Mr. Kevin Pittman (# 3387000246).

According to HUD, a reading of 1.0 mg/cm2 or greater on the XRF indicates the presence of LBP. If a component is found to be positive, then similar components throughout the building which were not tested are also considered to be positive. Wall A is used as the wall on the front of the building. The walls are then labeled B, C, and D in a clockwise direction as if you would look down on the room.

The following table lists the tested components.

No. Substrate Component Color Location Classification (pos, neg, inc)

L-1 Particle

Board Ceiling White Foyer Entrance NEG

L-2 Particle

Board Ceiling White Dine Room NEG

L-3 Particle

Board Ceiling White Kitchen NEG

L-4 Particle

Board Ceiling White Living Room NEG

L-5 Particle

Board Ceiling White Bedroom #1 NEG

L-6 Particle

Board Ceiling White Master bedroom NEG

L-7 Particle

Board Ceiling White Master bedroom Bathroom NEG

L-8 Particle

Board Ceiling White Hall Bathroom NEG

L-9 Particle

Board Ceiling White Hall NEG

L-10 Wood Door Stain Dine Room- A NEG

L-11 Wood Door Jam Stain Dine Room- A NEG

L-12 Wood Baseboard Stain Dine Room- A NEG

L-13 Wood Window Stain Dine Room- A NEG

L-14 Wood Window Sill Stain Dine Room- A NEG

L-15 Wood Window Frame Stain Dine Room- A NEG

L-16 Wood Door Stain Master Bedroom -B NEG

L-17 Wood Door Jam Stain Master Bedroom -B NEG

L-18 Wood Baseboard Stain Master Bedroom -D NEG

L-19 Wood Window Stain Master Bedroom -D NEG

L-20 Wood Window Sill Stain Master Bedroom -D NEG

L-21 Wood Window Frame Stain Master Bedroom -D NEG

4735 Great Heron Circle, Fairfax, VA 22033 / (571) 405-0985 / bradford.jordan@jordan-environmental.com

RECOMMENDATIONS

If any lead-based paint was detected, then any renovation and/or demolition activities that may disturb lead-based paint containing building structures should be conducted in accordance with all regulations governing handling lead based paint containing building structures in construction.

The LBP surfaces could become LBP hazard if:

LBP on friction surfaces is subject to abrasion.

The LBP is damaged or deteriorated.

Building renovation and/or demolition activities have the potential to produce hazardous wastes if lead-based paint is dry scraped, dry sanded, or heated. The hazardous waste criteria for lead wastes is established under the Federal Resource Conservation and Recovery Act (RCRA), Subtitle C, as

5.0 mg/L measured with the determine disposal options. The lead-based paint debris generated during demolition Toxicity Characteristic Leaching Procedure (TCLP) as listed in CFR 40 Part

261. A representative sample of demolition debris should also be collected for purposes of TCLP testing to should be handled in accordance with all applicable federal, state and local regulations.

JES recommends that Lead containing materials be removed by a certified abatement company prior to any planned demolition/renovation activities within the property. During any renovation or demolition activities if lead is removed, do not dry scrap, sand or abrade any lead containing materials. Lead paint was Not detected during inspection.

Respectfully Submitted,

A06 Apple House Lead and ACM
A06 Lauber House lead and ACM
A06 McCants House Lead and ACM
A06 Trailer Asbestos and LBP Report for NPS

File details come from the government source that posted it. Updated .