FEWR NO: H20-00049-3J

LOCATION : B1020, THAAD SITE

1/8

THIS PROJECT

B1020, THAAD SITE

LOCATION PLAN

NTS

FEWR NO: H20-00049-3J

LOCATION : B1020, THAAD SITE

2/8

REPLACE 1EA DOUBLE PANE WINDOW AT THIS LOCATION

FOR WINDOW DETAILS, SEE DRAWING #8/8

- GENERAL NOTE -

1. ALL WINDOWS MUST BE VERIFIED IN THE FIELD. MEASURE EXACT DIMENSION

OF WINDOWS IN THE FIELD BEFORE REPLACEMENT.

SECTION 1

IN FIRST FLOOR (1F)

NOT ACCESSIBLE FROM

INSIDE THE BUILDING

ACCESSIBLE FROM

INSIDE THE BUILDING

WINDOW REPLACEMENT PLAN-1

- SCOPE OF WORK -

1. REPLACE 30 BROKEN WINDOWS IN THAAD SITE.

2. THERE ARE 6 SECTIONS. IN EACH SECTION, IT IS SHOWN SIZE

AND LOCATION OF BROKEN WINDOWS.

3. SEAL ALL REPLACED WINDOWS BY SILICONE.

(SILICONE COLOR MUST MATCH WITH CURRENT SEALANT)

1ST FLOORUNIT : MM

NTS

2. THE CONTRACTOR SHOULD COORDINATE ANY SALVAGEABLE AND RECYCLABLE

MATERIALS WITHIN PROJECT LIMIT WITH COR CAREFULLY TO DETERMINE PROPER

MATERIAL HANDING METHODS.

3/8

SECTION 2

IN FIRST FLOOR (1F)

2600 26002600 2600

WINDOW REPLACEMENT PLAN-2

NOT ACCESSIBLE FROM

INSIDE THE BUILDING

ACCESSIBLE FROM

INSIDE THE BUILDING

REPLACE 7EA DOUBLE PANE WINDOWS AT THIS LOCATION

FOR WINDOW DETAILS, SEE DRAWING #8/8

1ST FLOORUNIT : MM

4/8

SECTION 3

IN FIRST FLOOR (1F)

WINDOW REPLACEMENT PLAN-3

NOT ACCESSIBLE FROM

INSIDE THE BUILDING

ACCESSIBLE FROM

INSIDE THE BUILDING

REPLACE 16EA DOUBLE PANE WINDOWS AT THIS LOCATION

FOR WINDOW DETAILS, SEE DRAWING #8/8

G.LUNIT : MM

5/8

SECTION 4

WINDOW REPLACEMENT PLAN-4

NOT ACCESSIBLE FROM

INSIDE THE BUILDING

ACCESSIBLE FROM

INSIDE THE BUILDING

REPLACE 2EA DOUBLE PANE WINDOWS AT THIS LOCATION

FOR WINDOW DETAILS, SEE DRAWING #8/8

1ST FLOOR G.LUNIT : MM

6/8

0SECTION 5

IN FIRST FLOOR (1F)

WINDOW REPLACEMENT PLAN-5

NOT ACCESSIBLE FROM

INSIDE THE BUILDING

ACCESSIBLE FROM

INSIDE THE BUILDING

REPLACE 1EA DOUBLE PANE WINDOW AT THIS LOCATION

FOR WINDOW DETAILS, SEE DRAWING #8/8

1ST FLOORUNIT : MM

7/8

SECTION 6

IN FIRST FLOOR (1F)

WINDOW REPLACEMENT PLAN-6

NOT ACCESSIBLE FROM

INSIDE THE BUILDING

ACCESSIBLE FROM

INSIDE THE BUILDING

REPLACE 3EA DOUBLE PANE WINDOWS AT THIS LOCATION

FOR WINDOW DETAILS, SEE DRAWING #8/8

1ST FLOOR

1ST FLOOR

UNIT : MM

8/8

WINDOW REPLACEMENT DETAILS

6MM CLEAR TEMPERED GLASS

6MM LOW E TEMPERED GLASS

12MM ARGON GAS FILLED

SILICONE SEALANT

MORE THAN 6MM DEPTH, 12MM WIDTH

OUTSIDE INSIDE

LOW E COATING

- REMARK -

1. NEW WINDOWS MUST BE DUAL PANE LOW E WINDOWS

2. ALL GLASSES OF WINDOWS MUST BE TEMPERED GLASSES.

6 12 6UNIT : MM

SIDE VIEW OF NEW WINDOWNEW INSTALLATION DETAILS

사드창문1
Sheets and Views
Model
사드창문2
Sheets and Views
Model
사드창문3
Sheets and Views
Model
사드창문4
Sheets and Views
Model
사드창문5
Sheets and Views
Model
사드창문6
Sheets and Views
Model
사드창문7
Sheets and Views
Model
사드창문8
Sheets and Views
Model
사드창문
Sheets and Views
Model

File details come from the government source that posted it. Updated .