This file contains design drawings and architectural/mechanical documentation for a laboratory renovation project at the USDA Agricultural Research Service facility in Wapato, Washington (Project 25-005). The renovation involves transforming existing lab spaces (Research Labs 416, 424, 425, and 426) within the Temperate Tree Fruit & Vegetable Research Unit into modernized research facilities with updated mechanical, plumbing, and electrical systems.

The scope of work includes demolition of existing casework, wall-mounted equipment, ceiling systems, and select partitions; installation of new painted steel casework and epoxy countertops with integrated sinks and faucets; new sheet vinyl flooring with coved bases; new gypsum wallboard partitions with fire-rated assemblies (1-hour and 2-hour ratings specified); new acoustic ceiling tile systems; and updated HVAC systems including new exhaust fans (N-EF-1 and N-EF-2), fume hoods (N-FH-1 and N-FH-2), re-heat coils, and air control valves to maintain negative pressure environments (minimum 0.01" WC) in biosafety lab spaces. The design incorporates fire suppression, accessibility compliance per ABASS standards, and integration with the facility's DDC (direct digital control) system. Design drawings indicate compliance with 2024 International Building Code, NFPA standards, ASHRAE ventilation standards, and Washington State Energy Code. The project includes both base bid and add alternate options, with the add alternate involving removal and replacement of existing casework in specific lab areas. Documentation includes floor plans, reflected ceiling plans, equipment elevations, 3D views, mechanical/plumbing demolition plans, and detailed specifications for partition types, door schedules, and mechanical sequences of operation.

View the file

Other files for this federal contract opportunity

Show all 11

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ACCESSIBILITY CODE

FEDERAL ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARDS (ABASS), REV 2015

PG-18-13 VA FIRE BARRIER (A SUPPLEMENT TO FEDERAL BARRIERS ACT ACCESSIBILITY

STANDARDS) FIRE DESIGN GUIDE, DEC 2011

BUILDING CODES

INTERNATIONAL CODE COUNCIL (ICC)

IBC—INTERNATIONAL BUILDING CODE, 2024

IFC—INTERNATIONAL FIRE CODE, 2024

IFGC—INTERNATIONAL FUEL GAS CODE, 2024

IMC—INTERNATIONAL MECHANICAL CODE, 2024

IPC—INTERNATIONAL PLUMBING CODE, 2024

NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)

NFPA 1: FIRE CODE, 2024

NFPA 10: STANDARD FOR PORTABLE FIRE EXTINGUISHERS, 2026

NFPA 13: STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS, 2025

NFPA 30: FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE, 2024

NFPA 70: NATIONAL ELECTRICAL CODE, 2026

NFPA 70E: STANDARD FOR ELECTRICAL SAFETY IN THE WORKPLACE, 2024

NFPA 72: NATIONAL FIRE ALARM AND SIGNALING CODE, 2025

NFPA 75: STANDARD FOR THE FIRE PROTECTION OF INFORMATION TECHNOLOGY EQUIPMENT, 2024

NFPA 101: LIFE SAFETY CODE, 2024

NFPA 241: STANDARD FOR SAFEGUARDING CONSTRUCTION, ALTERATION, AND DEMOLITION OPERATIONS, 2022 NFPA 291: RECOMMENDED PRACTICE FOR WATER FLOW TESTING AND MARKING OF HYDRANTS, 2025

NFPA 2001: STANDARD ON CLEAN AGENT FIRE EXTINGUISHING SYSTEMS 2025

NATIONAL INSTITUTE OF HEALTH

DESIGN REQUIREMENTS MANUAL - MARCH 2020

MECHANICAL DESIGN STANDARDS

AMERICAN SOCIETY OF HEATING, REFRIGERATION, AND AIR-CONDITIONING ENGINEERS (ASHRAE) STANDARD 52.2 – METHOD OF TESTING - GENERAL VENTILATION AIR-CLEANING DEVICES FOR REMOVAL EFFICENCY BY PARTICLE SIZE, STANDARD 62.1 – VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY, 2017

STANDARD 90.1 - ENERGY STANDARD FOR BUILDINGS EXCEPT LOW-RISE RESIDENTIAL BUILDINGS, 2013

STANDARD 170 - VENTILATION OF HEALTH CARE FACILITIES, 2021

SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION

HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE

HVAC SYSTEMS COMMISSIONING MANUAL, 2ND EDITION, 2013

SEISMIC RESTRAINT MANUAL GUIDELINES FOR MECHANICAL SYSTEMS, 3RD EDITION, 2008

ELECTRICAL DESIGN STANDARDS

UNDERWRITER’S LABORATORY, INC (UL) STANDARDS – 2019

ANSI/TIA-568-D SERIES, COMMERCIAL BUILDING TELECOMMUNICATIONS CABLING STANDARD, AND ITS PUBLISHED ADDENDA. -2017 ANSI/TIA 568.0-E, GENERIC TELECOMMUNICATIONS CABLING FOR CUSTOMER PREMISES, AND ITS PUBLISHED ADDENDA. – 2017 ANSI/TIA 568.1-E, COMMERCIAL BUILDING TELECOMMUNICATIONS CABLING STANDARD, AND ITS PUBLISHED ADDENDA. – 2017 ANSI/TIA 568.2-D, BALANCED TWISTED-PAIR TELECOMMUNICATIONS CABLING AND COMPONENTS. 2017

ANSI/TIA 568.3-D, OPTICAL FIBER CABLING COMPONENTS STANDARD, AND ITS PUBLISHED

ADDENDA. – 2017

ANSI/TIA 568.4-D BROADBAND COAXIAL CABLING AND COMPONENTS STANDARD

ANSI/TIA-569-C, COMMERCIAL BUILDING STANDARD FOR TELECOMMUNICATIONS PATHWAYS AND SPACES, AND ITS PUBLISHED

ADDENDA. – 2017

ANSI/TIA-606-A, ADMINISTRATION STANDARD FOR THE TELECOMMUNICATIONS INFRASTRUCTURE OF COMMERCIAL BUILDINGS, AND

ITS PUBLISHED ADDENDA – 2017

ANSI/J-STD-607-A, COMMERCIAL BUILDING GROUNDING (EARTHING) AND BONDING REQUIREMENTS FOR TELECOMMUNICATIONS, AND

ITS PUBLISHED ADDENDA. – 2017

BUILDING INDUSTRIES CONSULTING SERVICES INTERNATIONAL (BICSI) – 2019

TELECOMMUNICATIONS DISTRIBUTION METHODS MANUAL (TDMM) -2020

NFPA 70E, 2021

STRUCTURAL ENGINEERING DESIGN STANDARDS

AMERICAN CONCRETE INSTITUTE (ACI 2019)

AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC 15TH EDITION)

AMERICAN SOCIETY OF CIVIL ENGINEERS (ASCE 7-16)

CIVIL ENGINEERING DESIGN STANDARDS

INTERNATIONAL BUILDING CODE (IBC) — 2018

OWNER

ARCHITECTURAL PLUMBING

ELECTRICALMECHANICAL

COST ESTIMATOR

FIRE PROTECTION

USDA

GDM-AE, Inc. GDM-AE, Inc.

GDM-AE, Inc.GDM-AE, Inc.

PRO DIMS

GDM-AE, Inc.

5230 KONNOWAC PASS RD

Eric Shreve Scotten Blair

Alex WalkerScotten Blair

Dennis Teschong

Conrad Chandler

WAPATO, WA 98951

2309 Renard Place SE, Suite 209 4317 6th Avenue SE Suite 300

1308 NE 134th Street, Suite A4317 6th Avenue SE Suite 300

520 Kirkland Way, Suite 301

1308 NE 134th Street, Suite A

(202) 720-2791

Albuquerque, NM 87106 Anchorage, AK 99503

Vancouver, WA 98685Anchorage, AK 99503

Kirkland WA. 98033-6256

Vancouver, WA 98685

PROJECT NO. DRAWING NO.

MA

FLS

ISSUE DATE

CHECKED BY

DRAWN BY

DRAWING TITLE

APPROVED:

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHASE

321 4 5 6 7 8 9 10

LOCATION

''1

NOT FOR CONSTRUCTION

FOR OFFICIAL USE ONLY (FOUO)

FULLY

SPRINKLERED

ARCHITECT/ENGINEER OF RECORD

Agricultural Research Service

U

USDA AGRICULTURAL RESEARCH SERVICE

AGRICULTURAL

RESEARCH SERVICE

USDA/ARS, PA

S D A

USDA A-E FIRM

EPM

PPM

SAFETY & HEALTH

REAL PROPERTY

PROJECT MANAGER

XX

XX

XX

XX

JOB NO.

25-005

GDM-AE, Inc.

1308 NE 134th ST. SUITE A

VANCOUVER, WA 98685

P: 541.436.4723

WWW.GDM-AE.COM

STAMP

APPLICABLE CODES, REGULATIONS AND DESIGN MANUALS

PROJECT TEAM

USDA

A u to d e s k D o c s /2

-0

U S

D A

W a p a to /2

-0

U S

D A

W a p a to A rc h

R

.r v t

G-001

COVER SHEET

MA

SMW

RENOVATE LAB SPACE

TEMPERATE TREE FRUIT & VEGETABLE RESEARCH UNIT

100% DESIGN SUBMITTAL

25-005

5230 KONNOWAC PASS RD

WAPATO, WA 98951

03/19/2026

5230 KONNOWAC PASS RD

TEMPERATE TREE FRUIT & VEGETABLE RESEARCH UNIT

RENOVATE LAB SPACE

100% DESIGN SUBMITTAL

WAPATO, WA 98951

03-19-2026

50% DESIGN SUBMITTAL

95% DESIGN SUBMITTAL

100% DESIGN SUBMITTAL

01/09/2026 03/02/2026 03/19/2026

Revisions: Date:

eshreve Stamp eshreve Text Box 3-19-2026

1i

NORTH ARROW

STRUCTURAL GRIDLINE

BUILDING SECTION /

WALL SECTION

ID

DWG#

DWG#

ID

EXTERIOR ELEVATIONS

INTERIOR ELEVATIONS DWG#

ID

DWG#

ENLARGED DETAIL DRAWING

ROOM NAME AND NUMBER

WINDOW TYPE

PARTITION TYPE

ELEVATION MARK

DOOR NUMBER

0' - 0"

X

GENERAL SYMBOLS LEGEND

NORTH

1t

NORTH

EAST

SOUTH

WEST

REVISION TAG

DETAIL CALLOUT

ID

DWG#

Room name

REVISION CLOUD

REFERENCE KEYNOTE 00.00

SHEET KEYNOTE

ID

DIVISION

NOTE NUMBER

GENERAL NOTES DRAWING INDEX

USDA-LAB

RENOVATION

USDA TEMPERATE TREE FRUIT & VEGETABLE RESEARCH UNIT

USDA-ARS

WAPATO

USDA-ARS

WAPATO

USDA-ARS

WAPATO

PHYSIO

BEHAVIOR

LAB

INSECT

ECOLOGY

LAB

MECHANICAL

ROOM

KITCHEN

SET UP

GENERATOR

ELECTRICAL

ROOM

HARVEST

CLEAN

STOR

COLD

RM

COLD

RM

DRY

STOR

INSECT

PATHALOGY

MICRO

TECH

WARM

EC

COLD

EC

STERILIZATION

RECEIVING

LOADING

DOCK

MECH

OFFICE

SHOWER

TOILET

LOCKER

VESTIBULE

VESTIBULE

WORK

RM

WORK

RM

COLD

RM

STORAGE

ALCOVE

REARREAR

QUAR

ALCOVE

PROJECT NO. DRAWING NO.

MA

FLS

ISSUE DATE

CHECKED BY

DRAWN BY

DRAWING TITLE

APPROVED:

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHASE

321 4 5 6 7 8 9 10

LOCATION

''1

NOT FOR CONSTRUCTION

FOR OFFICIAL USE ONLY (FOUO)

FULLY

SPRINKLERED

ARCHITECT/ENGINEER OF RECORD

Agricultural Research Service

U

USDA AGRICULTURAL RESEARCH SERVICE

AGRICULTURAL

RESEARCH SERVICE

USDA/ARS, PA

S D A

USDA A-E FIRM

EPM

PPM

SAFETY & HEALTH

REAL PROPERTY

PROJECT MANAGER

GDM-AE, Inc.

1308 NE 134th ST. SUITE A

VANCOUVER, WA 98685

P: 541.436.4723

WWW.GDM-AE.COM

STAMP

A u to d e s k D o c s /2

-0

U S

D A

W a p a to /2

-0

U S

D A

W a p a to A rc h

R

.r v t

G-010

GENERAL INFORMATION

MA

SMW

RENOVATE LAB SPACE

TEMPERATE TREE FRUIT & VEGETABLE RESEARCH UNIT

100% DESIGN SUBMITTAL

25-005

5230 KONNOWAC PASS RD

WAPATO, WA 98951

03/19/2026

50% DESIGN SUBMITTAL

95% DESIGN SUBMITTAL

100% DESIGN SUBMITTAL

01/09/2026 03/02/2026 03/19/2026

REGIONAL MAP AREA MAP VICINITY MAP

RENOVATION KEY PLAN

Revisions: Date:

43 EJ001 ELECTRICAL ONE-LINES

42 EP003 LIGHTING PHOTOMETRY & REPORTS

41 EP002 ROOF ELECTRICAL PLAN

40 EP001 LEVEL 1 ELECTRICAL PLAN

39 ED001 LEVEL 1 ELECTRICAL DEMOLITION PLAN

38 EG001 LEGEND, ABBREVIATIONS, AND GENERAL REQUIREMENTS

ELECTRICAL

37 P7.0 DETAILS

36 P6.0 SCHEDULES

35 P2.3 PLUMBING PLAN- ADD ALT 1

34 P2.2 FIRST FLOOR LAB GAS PLAN

33 P2.1 FIRST FLOOR PLUMBING PLAN

32 P2.0 FOUNDATION FLOOR PLUMBING PLAN

31 P1.2 FIRST FLOOR LAB GAS DEMOLITION PLAN

30 P1.1 FIRST FLOOR PLUMBING DEMOLITION PLAN

29 P1.0 FOUNDATION FLOOR PLUMBING DEMOLITION PLAN

28 P0.2 PLUMBING SITE PLAN

27 P0.1 LEGEND, ABBREVIATION LIST, AND GENERAL NOTES

PLUMBING

26 M7.0 DETAILS

25 M6.0 SCHEDULES

24 M5.0 DIAGRAMS

23 M2.3 MECHANICAL PLAN- ADD ALT 1

22 M2.2 ROOF MECHANICAL PLAN

21 M2.1 MECHANICAL PIPING PLAN

20 M2.0 MECHANICAL PLAN

19 M1.1 MECHANICAL PIPING PLAN - DEMOLITION

18 M1.0 MECHANICAL PLAN - DEMOLITION

17 M0.2 MECHANICAL SITE PLAN

16 M0.1 LEGEND, ABBREVIATION LIST, SCHEDULES, AND GENERAL NOTES

MECHANICAL

15 A-145 LAB 424, 425 & 426 - 3D VIEWS

14 A-144 LAB 424, 425 & 426 - EQUIPMENT PLAN & ELEVATIONS

13 A-143 LAB 416 - 3D VIEWS

12 A-142 LAB 416 - 3D VIEWS

11 A-141 LAB 416 - EQUIPMENT PLAN & ELEVATIONS

10 A-130 ROOF PLAN

9 A-120 REFLECTED CEILING PLAN

8 A-100 FLOOR PLAN

7 A-020 FINISH SCHEDULE

6 A-010 DOOR & PARTITION TYPES & DETAILS

5 AD-130 ROOF DEMOLITION PLAN

4 AD-120 REFLECTED CEILING DEMOLITION PLAN

3 AD-100 DEMOLITION PLAN

ARCHITECT...

2 G-010 GENERAL INFORMATION

1 G-001 COVER SHEET

PROJECT GENERAL INFORMATION

PG SHEET DRAWING TITLE

eshreve Stamp eshreve

PROJECT NO. DRAWING NO.

MA

FLS

ISSUE DATE

CHECKED BY

DRAWN BY

DRAWING TITLE

APPROVED:

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHASE

321 4 5 6 7 8 9 10

LOCATION

''1

NOT FOR CONSTRUCTION

FOR OFFICIAL USE ONLY (FOUO)

FULLY

SPRINKLERED

ARCHITECT/ENGINEER OF RECORD

Agricultural Research Service

U

USDA AGRICULTURAL RESEARCH SERVICE

AGRICULTURAL

RESEARCH SERVICE

USDA/ARS, PA

S D A

USDA A-E FIRM

EPM

PPM

SAFETY & HEALTH

REAL PROPERTY

PROJECT MANAGER

GDM-AE, Inc.

1308 NE 134th ST. SUITE A

VANCOUVER, WA 98685

P: 541.436.4723

WWW.GDM-AE.COM

STAMP

A u to d e s k D o c s /2

-0

U S

D A

W a p a to /2

-0

U S

D A

W a p a to A rc h

R

.r v t

A-020

FINISH SCHEDULE

MA

BSC

RENOVATE LAB SPACE

TEMPERATE TREE FRUIT & VEGETABLE RESEARCH UNIT

100% DESIGN SUBMITTAL

25-005

5230 KONNOWAC PASS RD

WAPATO, WA 98951

03/19/2026

50% DESIGN SUBMITTAL

95% DESIGN SUBMITTAL

100% DESIGN SUBMITTAL

01/09/2026 03/02/2026 03/19/2026

Revisions: Date:

RESEARCH LAB 425 PAINTED STEEL

ADD ALTERNATE NUMBER 1

RESEARCH LAB 426 PAINTED STEEL

RESEARCH LAB 425 EXISTING

RESEARCH LAB 424 PAINTED STEEL

RESEARCH LAB 416 PAINTED STEEL

ROOM NAME ROOM NUMBER CASEWORK

Added Casework

RESEARCH LAB 426 EXISTING PT-1 PT-1 PT-1 PT-1 RB-1 VYNL

RESEARCH LAB 425 ACT PT-1 PT-1 PT-1 PT-1 RB-1 VYNL

ADD ALTERNATE NUMBER 1

CORR 721 EXISTING PT-2 EXISTING EXISTING EXISTING RB-1 EXISTING

RESEARCH LAB 426 EXISTING PT-1 PT-1 PT-1 PT-1 RB-1 VYNL

RESEARCH LAB 425 EXISTING EXISTING EXISTING EXISTING EXISTING RB-1 VYNL

RESEARCH LAB 424 ACT PT-1 PT-1 PT-1 PT-1 RB-1 VYNL

RESEARCH LAB 416 ACT PT-1 PT-1 PT-1 PT-1 RB-1 VYNL

ROOM NAME ROOM NUMBER CEILING FINISH WALL FINISH NORTH WALL FINISH EAST WALL FINISH SOUTH WALL FINISH WEST BASE FINISH FLOOR FINISH

ROOM FINISH SCHEDULE

ACT ACOUSTIC CEILING TILE WHERE INDICATED GLOBAL INDUSTRIAL MINERAL FIBER WHITE 48" X 24"

WP-1 WALL PROTECTION WHERE INDICATED FORMICA

HARDSTOP WALL

PROTECTION

5887h-58 MILLENNIUM

OAK MATTE

ORIENT GRAINS

HORIZONTALLY

PROFILES FOR INSIDE, DIVISION BAR AND END CAP TO MATCH. INSTALL PER

MANUFACTURE

VYNL SHEET VINYL FLOORING AS CALLED FOR ON SCHEDULE TARKETT iQ OPTIMA WHITE BEIGE GREY 0245 6.5' X 82' SKU: 3242245

RB-1 RUBBER BASE TYPICAL THOROUGH OUT TARKETT BASEWORKS... 63 BURNT UMBER 6" WITH TOE

EPX-1 EXPOXY COUNTER TYPICAL THROUGH OUT DURCON CLASSICTOP BLACK ONYX

PT-2 PAINT TYPICAL THROUGH OUT SHERWIN WILLIAMS PROMAR 200 ZERO VOC MATCH EXISITNG GLOSS FINISH - MATCH EXISITNG DOOR FRAME COLOR AND SCHEEN

PT-1 PAINT TYPICAL THROUGH OUT SHERWIN WILLIAMS PROMAR 200 ZERO VOC WHITE / GLOSS

MATERIA... MATERIAL TYPE APPLICATION INCLUDES BUT NOT LIMITED TO MANUFACTURE PRODUCT SYTLE / TYPE COLOR / FINISH DIMENSIONS REMARKS

FINISH LEGEND

eshreve Stamp eshreve

10.1 11.1 13.1

J

H.1

CLEAN STOR

HARVEST

KITCHEN

STERILIZATION

COLD RM

SET UP

COLD EC

CORR

VESTIBULE

MECHANICAL

ROOM

CORR

CORR

PHYSIO

BEHAVIOR LAB

INSECT ECOLOGY

LAB

WORK RM

CORR

PICK-UP

427A

CORR

HOLDING

HOLDING

HOLDING

HOLDING

HOLDING

HOLDING

WARM EC

427B

CORR

OVP SET-UP

OVP

OVP

OVP

Q C LAB

NOT IN SCOPE

OF WORK

NOT IN

SCOPE OF

WORK

NOT IN SCOPE

OF WORK

BASE BID:

EXISTING CASEWORK

TO REMAIN

BASE BID:

REMOVE EXISTING

CASEWORK AND WALL

MOUNTED EQUIPMENT

9D

9D

11D

1D

1D

1D 1D

1D

1D

1D

1D

1D

1D

1D

9D

8D

9D 9D

9D

4D7D

8D

12D

12D12D 12D

12D

12D

12D

4D

1D 12D

8D

8D

8D8D

8D

8D 8D

8D

8D

8D

8D

12D

12D

12D 12D

12D

PLAN LEGEND

GRAPHIC DESCRIPTION PRIORITY

2 HR SMOKE / FIRE

2 HR SHAFT 2

NON RATED PARTITION

NEW CONSTRUCTION

EXISTING PARTITION

TO BE DEMOLISHED

1 HR SMOKE / FIRE 4

1 HR FIRE 5

HAZARDOUS 6

2 HR FIRE

10.1

J

H.1

HARVEST

PHYSIO

BEHAVIOR LAB

CORR

PICK-UP

427A

CORR

Q C LAB

NOT IN SCOPE

OF WORK

ADD ALTERNATE :

REMOVE EXISTING

CASEWORK AND

REPLACE:

SEE (F1/A-144)

7D

8D

4D

12D

12D 12D

12D

4D

12D

12D

12D

GENERAL NOTES, DEMOLITION

1. FIELD VERIFY ALL EXISTING CONDITIONS, PRIOR TO START OF DEMOLITION.

BRING SIGNIFICANT DISCREPANCIES TO THE ATTENTION OF THE D.O.R. / OWNER

2. COORDINATE DEMOLITION PHASING AND SCHEDULE WITH THE OWNER.

3. THE OWNER RESERVES THE RIGHT TO HALT CONSTRUCTION ACTIVITY AT ANY

TIME DUE TO NOISE AND VIBRATION WHICH MIGHT AFFECT THE ONGOING USE

OF THE FACILITY.

4. PROTECT EXISTING CONSTRUCTION TO REMAIN FROM DAMAGE DURING

DEMOLITION, INCLUDING MECHANICAL & FIRE SUPPRESSION SYSTEMS.

5. OWNER WILL REMOVE ANY EXISTING FURNITURE AND MISC ITEMS IN ADVANCE

OF CONSTRUCTION. ALL REMAINING ITEMS TO BE REMOVED PER DRAWINGS

SHALL BE DISPOSED OF BY THE CONTRACTOR, OR SALVAGED TO WONER AS

NOTED.

6. EXISTING WALL MOUNTED DEVICES TO BE REMOVED UNLESS NOTED

OTHERWISE.

7. WHERE WALLS ARE INDICATED TO BE REMOVED, ANY UTILITIES FOUND WITHIN

SHALL BE REMOVED OR RE-ROUTED AS REQUIRED TO MAINTAIN THE

OPERATIONS OF ALL ADJACENT UNALTERED SPACES. WHEN UNEXPECTED

CONDITIONS ARISE NOTIFY THE DOR AND OWNER IMMEDIATELY.

8. REFER TO PLUMBING DRAWINGS FOR EXTENT OF REMOVAL AND INTENTIONS

FOR CAPPING OR RE-ROUTING OF EXISTING WATER, DRAIN, CONDENSATE,

STEAM, GAS AND SIMILAR LINES, WHERE FIXTURES ARE NOTED TO BE

REMOVED.

9. REFER TO MECHANICAL DRAWINGS FOR EXTENT OF DUCTWORK REMOVAL AND

INTENTIONS FOR CAPPING OR RE-ROUTING OF EXISTING DUCTWAORK WHERE

GRILL, DIFFUSER, AND REGISTER ARE NOTED TO BE REMOVED.

10. ALL DUCT OPENINGS INTO CONSTRUCTION AREAS SHALL BE COMPLETELY

SEALED TO PREVENT AIR CIRCULATION BETWEEN CONSTRUCTION ZONE AND

OCCUPIED AREAS VIA THE BUILDING HVAC SYSTEM.

11. REFER TO ELECTRICAL DRAWINGS FOR EXTENT OF CONDUIT AND CABLE

REMOVAL AND INTENTIONS FOR CIRCUTING AND RE-ROUTING OF EXISTING

ELECTRICAL WHERE DEVICES ARE NOTED TO BE REMOVED.

12. REMOVAL OF ASBESTOS CONTAINING AND OTHER POTENTIALLY HAZARDOUS

MATERIALS FROM THE BUILDING MUST FOLLOW STATE AND FEDERAL

REGULATIONS, AS WELL AS LOCAL LAWS WHEN APPLICABLE.

KEYNOTES

GENERAL NOTES, DEMOLITION

KEYNOTES

PROJECT NO. DRAWING NO.

MA

FLS

ISSUE DATE

CHECKED BY

DRAWN BY

DRAWING TITLE

APPROVED:

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHASE

321 4 5 6 7 8 9 10

LOCATION

''1

NOT FOR CONSTRUCTION

FOR OFFICIAL USE ONLY (FOUO)

FULLY

SPRINKLERED

ARCHITECT/ENGINEER OF RECORD

Agricultural Research Service

U

USDA AGRICULTURAL RESEARCH SERVICE

AGRICULTURAL

RESEARCH SERVICE

USDA/ARS, PA

S D A

USDA A-E FIRM

EPM

PPM

SAFETY & HEALTH

REAL PROPERTY

PROJECT MANAGER

GDM-AE, Inc.

1308 NE 134th ST. SUITE A

VANCOUVER, WA 98685

P: 541.436.4723

WWW.GDM-AE.COM

STAMP

A u to d e s k D o c s /2

-0

U S

D A

W a p a to /2

-0

U S

D A

W a p a to A rc h

R

.r v t

AD-100

DEMOLITION PLAN

MA

SMW

RENOVATE LAB SPACE

TEMPERATE TREE FRUIT & VEGETABLE RESEARCH UNIT

100% DESIGN SUBMITTAL

25-005

5230 KONNOWAC PASS RD

WAPATO, WA 98951

03/19/2026

50% DESIGN SUBMITTAL

95% DESIGN SUBMITTAL

100% DESIGN SUBMITTAL

01/09/2026 03/02/2026 03/19/2026

1D REMOVE EXISTING DOOR AND FRAME - SALVAGE TO OWNER

4D REMOVE EXISTING CASEWORK, WORK SPACES AND COUNTER TOPS

7D REMOVE EXISTING SINK AND PLUMBING FIXTURES - REFER TO PLUMBING

DRAWINGS FOR EXTENT.

8D REMOVE EXISTING SHEET VINYL FLOORING, INTEGRAL COVE BASE, METAL TRIM

AND ADHESIVE TO EXPOSE CLEAN CONCRETE SLAB

9D REMOVE EXISTING DRYWALL AND METAL STUD FRAMED WALL

11D REMOVE EXISTING WALL AND DOOR, RE-FRAME OPENING AS REQUIRED

12D REMOVE EXISTING GYPSUM BOARD SHEATHING. METAL STUD FRAMING TO

REMAIN

1/4" = 1'-0"F4 DEMOLITION PLAN - BASE BID

NORTH

0' 2' 4' 8'

1/4" = 1'-0"F2 DEMOLITION PLAN - ADD ALTERNATE

Revisions: Date:

eshreve Stamp eshreve

H.1

CLEAN STOR

HARVEST

KITCHEN

STERILIZATION

COLD RM

SET UP

COLD EC

CORR

VESTIBULE

MECHANICAL

ROOM

CORR

CORR

PHYSIO

BEHAVIOR LAB

INSECT ECOLOGY

LAB

WORK RM

CORR

PICK-UP

427A

CORR

HOLDING

HOLDING

HOLDING

HOLDING

HOLDING

HOLDING

WARM EC

427B

CORR

OVP SET-UP

OVP

OVP

OVP

Q C LAB

NOT IN SCOPE

OF WORK

NOT IN

SCOPE OF

WORK

NOT IN SCOPE

OF WORK

BASE BID:

EXISTING CEILING AND

LIGHTING TO REMAIN

BASE BID:

EXISTING CEILING AND

LIGHTING TO REMAIN

10D

10D

10D

10D

10D

10D

10D

10D

10D

10D

10D

10D

5D

5D

5D

6D

5D

5D

5D

5D

5D

5D5D

5D

5D

6D

6D 6D

GYP. BD. CEILING SYSTEM

DOWN LIGHT FIXTURE

CEILING LEGEND

2 X 4 ACOUSTICAL LAY-IN CEILING SYSTEM.

1 X 4 LIGHT FIXTURE

SUPPLY AIR DIFFUSER

2 X 4 LIGHT FIXTURE

SPRINKLER

EDGE STRIP LIGHT FIXTURE

RETURN AIR VENT

GRAPHIC DESCRIPTION

PLAN LEGEND

GRAPHIC DESCRIPTION PRIORITY

2 HR SMOKE / FIRE

2 HR SHAFT 2

NON RATED PARTITION

NEW CONSTRUCTION

EXISTING PARTITION

TO BE DEMOLISHED

1 HR SMOKE / FIRE 4

1 HR FIRE 5

HAZARDOUS 6

2 HR FIRE

10.1

J

H.1

HARVEST

PHYSIO

BEHAVIOR LAB

PICK-UP

427A

CORR

Q C LAB

NOT IN SCOPE

OF WORK

NOT IN SCOPE

OF WORK

ADD ALTERNATE :

REMOVE EXISTING

CEILING AND

LIGHTING

ADD ALTERNATE :

REMOVE EXISTING

CEILING AND

LIGHTING

10D

5D

6D

6D

5D

10D

6D

6D

GENERAL NOTES, DEMOLITION

1. FIELD VERIFY ALL EXISTING CONDITIONS, PRIOR TO START OF DEMOLITION.

BRING SIGNIFICANT DISCREPANCIES TO THE ATTENTION OF THE D.O.R. / OWNER

2. COORDINATE DEMOLITION PHASING AND SCHEDULE WITH THE OWNER.

3. THE OWNER RESERVES THE RIGHT TO HALT CONSTRUCTION ACTIVITY AT ANY

TIME DUE TO NOISE AND VIBRATION WHICH MIGHT AFFECT THE ONGOING USE

OF THE FACILITY.

4. PROTECT EXISTING CONSTRUCTION TO REMAIN FROM DAMAGE DURING

DEMOLITION, INCLUDING MECHANICAL & FIRE SUPPRESSION SYSTEMS.

5. OWNER WILL REMOVE ANY EXISTING FURNITURE AND MISC ITEMS IN ADVANCE

OF CONSTRUCTION. ALL REMAINING ITEMS TO BE REMOVED PER DRAWINGS

SHALL BE DISPOSED OF BY THE CONTRACTOR, OR SALVAGED TO WONER AS

NOTED.

6. EXISTING WALL MOUNTED DEVICES TO BE REMOVED UNLESS NOTED

OTHERWISE.

7. WHERE WALLS ARE INDICATED TO BE REMOVED, ANY UTILITIES FOUND WITHIN

SHALL BE REMOVED OR RE-ROUTED AS REQUIRED TO MAINTAIN THE

OPERATIONS OF ALL ADJACENT UNALTERED SPACES. WHEN UNEXPECTED

CONDITIONS ARISE NOTIFY THE DOR AND OWNER IMMEDIATELY.

8. REFER TO PLUMBING DRAWINGS FOR EXTENT OF REMOVAL AND INTENTIONS

FOR CAPPING OR RE-ROUTING OF EXISTING WATER, DRAIN, CONDENSATE,

STEAM, GAS AND SIMILAR LINES, WHERE FIXTURES ARE NOTED TO BE

REMOVED.

9. REFER TO MECHANICAL DRAWINGS FOR EXTENT OF DUCTWORK REMOVAL AND

INTENTIONS FOR CAPPING OR RE-ROUTING OF EXISTING DUCTWAORK WHERE

GRILL, DIFFUSER, AND REGISTER ARE NOTED TO BE REMOVED.

10. ALL DUCT OPENINGS INTO CONSTRUCTION AREAS SHALL BE COMPLETELY

SEALED TO PREVENT AIR CIRCULATION BETWEEN CONSTRUCTION ZONE AND

OCCUPIED AREAS VIA THE BUILDING HVAC SYSTEM.

11. REFER TO ELECTRICAL DRAWINGS FOR EXTENT OF CONDUIT AND CABLE

REMOVAL AND INTENTIONS FOR CIRCUTING AND RE-ROUTING OF EXISTING

ELECTRICAL WHERE DEVICES ARE NOTED TO BE REMOVED.

12. REMOVAL OF ASBESTOS CONTAINING AND OTHER POTENTIALLY HAZARDOUS

MATERIALS FROM THE BUILDING MUST FOLLOW STATE AND FEDERAL

REGULATIONS, AS WELL AS LOCAL LAWS WHEN APPLICABLE.

KEYNOTES

GENERAL NOTES, DEMOLITION

KEYNOTES

PROJECT NO. DRAWING NO.

MA

FLS

ISSUE DATE

CHECKED BY

DRAWN BY

DRAWING TITLE

APPROVED:

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHASE

321 4 5 6 7 8 9 10

LOCATION

''1

NOT FOR CONSTRUCTION

FOR OFFICIAL USE ONLY (FOUO)

FULLY

SPRINKLERED

ARCHITECT/ENGINEER OF RECORD

Agricultural Research Service

U

USDA AGRICULTURAL RESEARCH SERVICE

AGRICULTURAL

RESEARCH SERVICE

USDA/ARS, PA

S D A

USDA A-E FIRM

EPM

PPM

SAFETY & HEALTH

REAL PROPERTY

PROJECT MANAGER

GDM-AE, Inc.

1308 NE 134th ST. SUITE A

VANCOUVER, WA 98685

P: 541.436.4723

WWW.GDM-AE.COM

STAMP

A u to d e s k D o c s /2

-0

U S

D A

W a p a to /2

-0

U S

D A

W a p a to A rc h

R

.r v t

AD-120

REFLECTED CEILING DEMOLITION PLAN

MA

SMW

RENOVATE LAB SPACE

TEMPERATE TREE FRUIT & VEGETABLE RESEARCH UNIT

100% DESIGN SUBMITTAL

25-005

5230 KONNOWAC PASS RD

WAPATO, WA 98951

03/19/2026

50% DESIGN SUBMITTAL

95% DESIGN SUBMITTAL

100% DESIGN SUBMITTAL

01/09/2026 03/02/2026 03/19/2026

5D REMOVE EXISTING LIGHT FIXTURE - REFER TO ELECTRICAL DRAWINGS

6D REMOVE EXISTING MECHANICAL. - REFER TO MECHANICAL DRAWINGS

10D REMOVE EXISTING GYPSUM BOARD AND METAL JOIST CEILING

1/4" = 1'-0"F4 REFLECTED CEILING DEMOLITION PLAN - BASE BID

NORTH

0' 2' 4' 8'

1/4" = 1'-0"F2 REFLECTED CEILING DEMOLITION PLAN - ADD ALTERNATE

Revisions: Date:

eshreve Stamp eshreve

10.1 11.1 13.1 14

L

J

H.1

14D

14D

GENERAL NOTES, DEMOLITION

1. FIELD VERIFY ALL EXISTING CONDITIONS, PRIOR TO START OF DEMOLITION.

BRING SIGNIFICANT DISCREPANCIES TO THE ATTENTION OF THE D.O.R. / OWNER

2. COORDINATE DEMOLITION PHASING AND SCHEDULE WITH THE OWNER.

3. THE OWNER RESERVES THE RIGHT TO HALT CONSTRUCTION ACTIVITY AT ANY

TIME DUE TO NOISE AND VIBRATION WHICH MIGHT AFFECT THE ONGOING USE

OF THE FACILITY.

4. PROTECT EXISTING CONSTRUCTION TO REMAIN FROM DAMAGE DURING

DEMOLITION, INCLUDING MECHANICAL & FIRE SUPPRESSION SYSTEMS.

5. OWNER WILL REMOVE ANY EXISTING FURNITURE AND MISC ITEMS IN ADVANCE

OF CONSTRUCTION. ALL REMAINING ITEMS TO BE REMOVED PER DRAWINGS

SHALL BE DISPOSED OF BY THE CONTRACTOR, OR SALVAGED TO WONER AS

NOTED.

6. EXISTING WALL MOUNTED DEVICES TO BE REMOVED UNLESS NOTED

OTHERWISE.

7. WHERE WALLS ARE INDICATED TO BE REMOVED, ANY UTILITIES FOUND WITHIN

SHALL BE REMOVED OR RE-ROUTED AS REQUIRED TO MAINTAIN THE

OPERATIONS OF ALL ADJACENT UNALTERED SPACES. WHEN UNEXPECTED

CONDITIONS ARISE NOTIFY THE DOR AND OWNER IMMEDIATELY.

8. REFER TO PLUMBING DRAWINGS FOR EXTENT OF REMOVAL AND INTENTIONS

FOR CAPPING OR RE-ROUTING OF EXISTING WATER, DRAIN, CONDENSATE,

STEAM, GAS AND SIMILAR LINES, WHERE FIXTURES ARE NOTED TO BE

REMOVED.

9. REFER TO MECHANICAL DRAWINGS FOR EXTENT OF DUCTWORK REMOVAL AND

INTENTIONS FOR CAPPING OR RE-ROUTING OF EXISTING DUCTWAORK WHERE

GRILL, DIFFUSER, AND REGISTER ARE NOTED TO BE REMOVED.

10. ALL DUCT OPENINGS INTO CONSTRUCTION AREAS SHALL BE COMPLETELY

SEALED TO PREVENT AIR CIRCULATION BETWEEN CONSTRUCTION ZONE AND

OCCUPIED AREAS VIA THE BUILDING HVAC SYSTEM.

11. REFER TO ELECTRICAL DRAWINGS FOR EXTENT OF CONDUIT AND CABLE

REMOVAL AND INTENTIONS FOR CIRCUTING AND RE-ROUTING OF EXISTING

ELECTRICAL WHERE DEVICES ARE NOTED TO BE REMOVED.

12. REMOVAL OF ASBESTOS CONTAINING AND OTHER POTENTIALLY HAZARDOUS

MATERIALS FROM THE BUILDING MUST FOLLOW STATE AND FEDERAL

REGULATIONS, AS WELL AS LOCAL LAWS WHEN APPLICABLE.

KEYNOTES

GENERAL NOTES, DEMOLITION

KEYNOTES

PROJECT NO. DRAWING NO.

MA

FLS

ISSUE DATE

CHECKED BY

DRAWN BY

DRAWING TITLE

APPROVED:

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHASE

321 4 5 6 7 8 9 10

LOCATION

''1

NOT FOR CONSTRUCTION

FOR OFFICIAL USE ONLY (FOUO)

FULLY

SPRINKLERED

ARCHITECT/ENGINEER OF RECORD

Agricultural Research Service

U

USDA AGRICULTURAL RESEARCH SERVICE

AGRICULTURAL

RESEARCH SERVICE

USDA/ARS, PA

S D A

USDA A-E FIRM

EPM

PPM

SAFETY & HEALTH

REAL PROPERTY

PROJECT MANAGER

GDM-AE, Inc.

1308 NE 134th ST. SUITE A

VANCOUVER, WA 98685

P: 541.436.4723

WWW.GDM-AE.COM

STAMP

A u to d e s k D o c s /2

-0

U S

D A

W a p a to /2

-0

U S

D A

W a p a to A rc h

R

.r v t

AD-130

ROOF DEMOLITION PLAN

MA

SMW

RENOVATE LAB SPACE

TEMPERATE TREE FRUIT & VEGETABLE RESEARCH UNIT

100% DESIGN SUBMITTAL

25-005

5230 KONNOWAC PASS RD

WAPATO, WA 98951

03/19/2026

50% DESIGN SUBMITTAL

95% DESIGN SUBMITTAL

100% DESIGN SUBMITTAL

01/09/2026 03/02/2026 03/19/2026

3/16" = 1'-0"F2 ROOF DEMOLITION PLAN

NORTH

0' 4' 8' 12'

14D REMOVE EXISTING ROOFING SYSTEM TO ALLOW FOR NEW FUME HOOD EXHAUST

SYSTEM, RE-FRAME & REINFORCE OPENING AS REQUIRED

Revisions: Date:

eshreve Stamp eshreve

SEALANT EACH SIDE

(AT RATED WALLS SEALANT

TO BE FIRE RATED PER FIRE

DESIGN INDICATED)

5/8" TYPE X GYPSUM

WALLBOARD

A

PARTITION

TYPE

METAL STUD DECK TO DECK, 5/8"

GYPSUM WALLBOARD EACH SIDE.

RATED WHERE INDICATED

SOUND ATTENUATION

BATT WHERE INDICATED

(s)

SEALANT EACH SIDE

(AT RATED WALLS SEALANT

TO BE FIRE RATED PER FIRE

DESIGN INDICATED)

DEFLECTION TRACK TYP.

1 HOUR FIRE DESIGN: GA FILE NO. WP 1072

ONE LAYER 5/8" TYPE X GYPSUM WALLBOARD OR GYPSUM

VENEER BASE APPLIED PARALLEL OR AT RIGHT ANGLES TO

EACH SIDE OF 3-5/8", 18 MIL STEEL STUDS 24" O.C. WITH 1"

TYPE S SCREWS 8" O.C. AT VERTICAL JOINTS AND 12" O.C.

AT FLOOR AND CEILING RUNNERS AND INTERMEDIATE

STUDS. JOINTS STAGGERED 24" ON EACH SIDE AND ON

OPPOSITE SIDES (NLB)

2 HOUR FIRE DESIGN: GA FILE NO. WP 1616

BASE: LAYER 5/8" TYPE X GYPSUM WALLBOARD OR GYPSUM

VENEER BASE APPLIED PARALLEL OR AT RIGHT ANGLES TO

EACH SIDE OF 3-5/8", 18 MIL STEEL STUDS 24" O.C. WITH 1"

TYPE S SCREWS 8" O.C. AT VERTICAL JOINTS AND 12" O.C.

AT INTERMEDIATE STUDS.

FACE: LAYER 5/8" TYPE X GYPSUM WALLBOARD OR GYPSUM

VENEER BASE APPLIED PARALLEL TO EACH SIDE WITH

LAMINATING COMPUND COMBED OVER ENTIRE SURFACE.

SOUND DESIGN: 40 TO 49 STC

SOUND TESTED WITH 3-1/2" GLASS FIBER FRICTION FIT IN

STUD CAVITY.

FIRE TEST: UL DESIGN U411

STENCIL: ON WALL EVERY 10'-0" ABOVE CEILING WITH 5"

LETTERING - LISTING OR RATING IN RED PAINT

CEILING

METAL STUDS

MAXIMUM INTERIOR WALL HEIGHT

SECTION

(STUD WIDTH)

162S125 (1 5/8")

NON COMPOSITE

FULLY BRACED

L/240 5psf

10'-1"

STUD SPACING

(INCHES)

16"

DESIGN

MIL (GAUGE)

18 (25)

COMPOSITE WALL

L/240 5psf

27 (20)

8'-9"24"

10'-7"16"

9'-1"24"

250S125 (2 1/2")

16"

11'-3"24"

13'-11"16"

12'-2"24"

12'-10"

362S125 (3 5/8")

16"

13'-2"24"

16'-6"16"

14'-5"24"

15'-2"

400S125 (4")

16"

13'-8"24"

17'-8"16"

15'-5"24"

15'-11"

600S125 (6")

16"

16'-4"24"

24'-4"16"

21'-3"24"

20'-1"

7'-1"

5'-11"

8'-2"

7'-1"

8'-2"

11'-3"

9'-11"

9'-8"

9'-3"

15'-0"

12'-5"

11'-4"

9'-9"

16'-1"

13'-1"

11'-11"

17'-6"

23'-11"

20'-5"

21'-5"

18 (25)

27 (20)

18 (25)

27 (20)

18 (25)

27 (20)

18 (25)

27 (20)

TAG GRAPHICS

A 6 m

PARTITION SERIES

FRAMING SIZE

MODIFIER

PARTITION TAG LEGEND

MODIFIER LIST:

b = SMOKE f = FIRE RATED g = GYPSUM BOARD BOTH SIDES s = SOUND ATTENUATION t = THERMAL INSULATION v = VAPOR BARRIER w = WATER PROOFING

A FULL HEIGHT METAL STUDS

PARTITION SERIES

B FULL HEIGHT METAL STUDS

C FULL HEIGHT METAL STUDS

D PARTIAL HEIGHT METAL STUDS, ABOVE

CEILING

E PARTIAL HEIGHT METAL STUDS TO

CEILING

F METAL FURRING

G EXTERIOR WALL FURRING - FULL

HEIGHT

M MASONRY

P PARTIAL HEIGHT METAL STUD

(PONY WALL)

X EXISTING PARTITION

W WOOD FRAMED PARTITION

T TEMPORARY PARTITION

V SHAFT WALL 2 HOUR

Z SPECIALTY/CUSTOM

U SHAFT WALL 1 HOUR

FRAMING SIZE LEGEND

SIZE MASONRY

n/a

WOOD

n/a

METAL

n/a0 n/a n/a n/a

3-5/8" n/a

5-5/8" n/a

7-5/8" n/a

9-5/8" n/a

11-5/8" n/a n/a n/a

3-1/2" n/a

5-1/2" n/a

7-1/4" n/a n/a n/a n/a

7/8"

1-1/2"

2-1/2"

3-5/8"

4"

6"

2-1/2" & 3-5/8" n/a n/a n/a n/a n/a

LOWER PRIORITY WALL

HIGHER PRIORITY WALL

LOWER PRIORITY WALL

LOWER PRIORITY WALL

HIGHER PRIORITY WALL

P

PARTITION

TYPE

PARTIAL HEIGHT METAL STUD

(PONY WALL)

DEFLECTION TRACK

TYP.

METAL STUDS

DEFLECTION TRACK

TYP.

METAL STUDS

5/8" TYPE X GYPSUM

WALLBOARD

P

PARTIAL HEIGHT METAL STUD

(PONY WALL)CPARTITION

TYPE

FULL HEIGHT STUDS - 5/8" GYPSUM

WALLBOARD 1 SIDE

5/8" TYPE X GYPSUM

WALLBOARD

METAL STUDS

DEFLECTION TRACK

TYP.

DESIGN:

ONE LAYER 5/8" GYPSUM WALLBOARD OR GYPSUM

VENEER BASE APPLIED PARALLEL AT RIGHT OF 3-5/8"

METAL STUDS.

CEILING

R E

F E

R E

N C

E U

L H

W -D

-0

F O

R M

O R

E I N

F O

R M

A T

IO

N

1. USG SHEETROCK PANELS, REFERENCE UL HW-D-0001 FOR JOINT WIDTH INFORMATION

2. COMPLETELY FILL GAP ABOVE GYPSUM PANELS WITH USG SHEETROCK ACOUSTICAL

OR SMOKE-SOUND SEALANT

3. STRUCTURAL SLAB

4. USG SHEETROCK FIRECODE X PANELS, CUT 5/8" MAX. FROM TOP OF PARTITION

5. MIN. 1/2" [12.5] USG SHEETROCK FIRECODE COMPOUND

6. Z-CLIPS

7. STEEL WITH FIRE PROOFING

8. PLATE, EXTEND FIRE PROOFING FROM STEEL BEAM ONTO PLATE

9. MINERAL WOOL INSULATION

10. UNDERSIDE OF STRUCTURAL SLAB

11. CONTINUOUS 20-GAUGE ANGLE, FASTEN TO STUDS

12. PERFORATED METAL PLATE, SPAN BETWEEN FLUTES, HW-D-0001 FOR MORE

INFORMATION

13. RESTRAINING ANGLE LINED WITH GYPSUM BOARD, PARTITION BELOW

14. TO BE SET FLUSH ON DRYWALL SIDE

15. TRACK STUD

16. MIN. 1/2" [13] THICK USG SHEETROCK FIRECODE COMPOUND

17. WOOL BATT INSULATION

18. USG X PANELS, CUT 5/8" FROM UNDERSIDE OF PROTECTED STEEL PLATE

19. MINERAL WOOL FILL MATERIAL

20. CEILING HEAD AND RELIEF TRACK

21. LAP SEALANT 1/2" BELOW TOP GYPSUM PANELS (BOTH SIDES)

22. USG SHEETROCK X PANELS, BUTT TIGHT TO UNDERSIDE OF STEEL DECK, THICKNESS

PER ARCHITECT

23. USG X PANELS, CUT 1/2" MAX. FROM TOP OF PARTITION, THICKNESS PER ARCHITECT

24. USG X PANELS, REFERENCE UL HW-D-0002 FOR JOINT WIDTH INFORMATION

25. USG SHEETROCK FIRECODE X PANELS

26. COMPLETELY FILL GAP ABOVE GYPSUM PANELS WITH USG SHEETROCK ACOUSTICAL

OR SMOKE-SOUND SEALANT (BOTH SIDES)

27. STEEL BEAM FIRE PROOFING REFERENCE STRUCTURAL DRAWINGS FOR BEAM SIZE

AND FIREPROOFING THICKNESS

28. UNDERSIDE OF STRUCTURAL SLAB

29. FILL CAVITY WITH MINERAL WOOL

30. CUT DRYWALL SHORT OF DECK BY 5/8"

R E

F E

R E

N C

E U

L H

W -D

-0

F O

R M

O R

E I N

F O

R M

A T

IO

N

1. USG SHEETROCK PANELS, REFERENCE UL HW-D-0001 FOR JOINT WIDTH INFORMATION

2. COMPLETELY FILL GAP ABOVE GYPSUM PANELS WITH USG SHEETROCK ACOUSTICAL

OR SMOKE-SOUND SEALANT

3. STRUCTURAL SLAB

4. USG SHEETROCK FIRECODE X PANELS, CUT 5/8" MAX. FROM TOP OF PARTITION

5. MIN. 1/2" [12.5] USG SHEETROCK FIRECODE COMPOUND

6. Z-CLIPS

7. STEEL WITH FIRE PROOFING

8. PLATE, EXTEND FIRE PROOFING FROM STEEL BEAM ONTO PLATE

9. MINERAL WOOL INSULATION

10. UNDERSIDE OF STRUCTURAL SLAB

11. CONTINUOUS 20-GAUGE ANGLE, FASTEN TO STUDS

12. PERFORATED METAL PLATE, SPAN BETWEEN FLUTES, HW-D-0001 FOR MORE

INFORMATION

13. RESTRAINING ANGLE LINED WITH GYPSUM BOARD, PARTITION BELOW

14. TO BE SET FLUSH ON DRYWALL SIDE

15. TRACK STUD

16. MIN. 1/2" [13] THICK USG SHEETROCK FIRECODE COMPOUND

17. WOOL BATT INSULATION

18. USG X PANELS, CUT 5/8" FROM UNDERSIDE OF PROTECTED STEEL PLATE

19. MINERAL WOOL FILL MATERIAL

20. CEILING HEAD AND RELIEF TRACK

21. LAP SEALANT 1/2" BELOW TOP GYPSUM PANELS (BOTH SIDES)

22. USG SHEETROCK X PANELS, BUTT TIGHT TO UNDERSIDE OF STEEL DECK, THICKNESS

PER ARCHITECT

23. USG X PANELS, CUT 1/2" MAX. FROM TOP OF PARTITION, THICKNESS PER ARCHITECT

24. USG X PANELS, REFERENCE UL HW-D-0002 FOR JOINT WIDTH INFORMATION

25. USG SHEETROCK FIRECODE X PANELS

26. COMPLETELY FILL GAP ABOVE GYPSUM PANELS WITH USG SHEETROCK ACOUSTICAL

OR SMOKE-SOUND SEALANT (BOTH SIDES)

27. STEEL BEAM FIRE PROOFING REFERENCE STRUCTURAL DRAWINGS FOR BEAM SIZE

AND FIREPROOFING THICKNESS

28. UNDERSIDE OF STRUCTURAL SLAB

29. FILL CAVITY WITH MINERAL WOOL

30. CUT DRYWALL SHORT OF DECK BY 5/8"

DOORS / OPENING IN WALL

RUNNER TRACK AT

UNDERSIDE OF

CONSTRUCTION

CEILING LINE

DOUBLE 20 GAUGE

METAL STUDS TO

STRUCTURE AT JAMBS

AT ALL PARTITIONS,

INCLUDING CEILING

HEIGHT PARTITIONS

20 GAUGE METAL

STUD 6" FROM JAMB

TYP BOTH SIDES

RUNNER TRACK AT

FINISHED FLOOR

ADDITIONAL STUD AT

CONTROL JOINT

LOCATIONS

NON-STRUCTURAL METAL FRAMING

GYP. BOARD

ANCHOR

STANDARD

FRAME

1/2" 5/8"

PER PARTITION TYPE

METAL STUDS 5/8" 1/2"

METAL STUDS

TYPICAL TRACK W/

(1) SCREW PER STUD

FLANGE AS REQUIRED

(2) STUDS (PER SECTION),

(1) EA. SIDE OF PW STUD AS

SHOWN (STUD IN FRONT OF

PW STUD SHOWN DASHED

FOR CLARITY)

TOP TRACK, SEE PLAN

FOR WALL HEIGHT

PONY WALL SUPPORT AND

BASE PLATE @ 48" O.C.

SUPPORT HEIGHT 3/4

WALL HEIGHT MIN.

(1) 1/2"∅ ANCHOR AS

REQUIRED

(1) 1/2" THICK BASE PLATE

W/ PRE-DRILLED HOLES

SCREWS THROUGH WALL

OF STUDS EA. SIDE. TYP.

8"

1" 4"

5/8"

/1

/1

/8

BASE PLATE HOLE LAYOUT

MIN. ANCHOR

EDGE DISTANCE

AS REQUIRED

(HALF GLASS)

6"

RE: SCHED.

R E

S

C H

E D

6"

C

TYPICAL DOOR TYPE C

TYPICAL CONNECTION:

CUT FLANGES FROM WEB

AND BEND WEB UP FACE OF

STUD. PROVIDE TWO 3/4" #10

PAN HEAD SHEET METAL

SCTEWS. LOCATE SCREWS

1/2" UP FROM WEB AND 3/4" IN

FROM EACH END OF BENT

WEB

OPENINGS UP TO 3'-6" WIDE OPENINGS 3'-6" TO 8'-0" WIDE OPENINGS 8'-0" TO 12'-0" WIDE

DOUBLE 20 GAUGE METAL

STUDS TO STRUCTURE

CONTINUOUS RUNNER TRACK

DEPTH OF TRACK TO MATCH

DEPTH OF VERTICAL STUDS

AS INDICATED BY PARTITION

TYPE ON FLOOR PLANS

TYPICAL ALL HEAD TYPES

DOUBLE 20 GAUGE METAL

STUDS TO STRUCTURE

CONTINUOUS RUNNER TRACK

ATTACHED TO NESTED STUD

EXTEND RUNNER TRACK

FLANGES 1 5/8" MIN EACH SIDE

BEYOND FACE OF JAMB.

PROVIDE 3/4" LOW PROFILE #10

PAN HEAD SHEET METAL

SCREWS EACH SIDE

DOUBLE 20 GAUGE METAL

STUDS TO STRUCTURE

EXTEND RUNNER TRACK

FLANGES 1 5/8" MIN EACH SIDE

BEYOND FACE OF JAMB.

PROVIDE 3/4" LOW PROFILE #

10 PAN HEAD SHEET METAL

SCREWS EACH SIDE

CONTINUOUS METAL STUD

NESTED INTO BOTTOM

RUNNER TRACK

CONTINUOUS RUNNER TRACK

ATTACHED TO DOUBLE STUD

TWO CONTINUOUS 4" METAL

STUDS TURNED ON EDGE

AND NESTED INTO BOTTOM

RUNNER TRACK

NON-STRUCTURAL METAL FRAMING PROJECT NO. DRAWING NO.

MA

FLS

ISSUE DATE

CHECKED BY

DRAWN BY

DRAWING TITLE

APPROVED:

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHASE

321 4 5 6 7 8 9 10

LOCATION

''1

NOT FOR CONSTRUCTION

FOR OFFICIAL USE ONLY (FOUO)

FULLY

SPRINKLERED

ARCHITECT/ENGINEER OF RECORD

Agricultural Research Service

U

USDA AGRICULTURAL RESEARCH SERVICE

AGRICULTURAL

RESEARCH SERVICE

USDA/ARS, PA

S D A

USDA A-E FIRM

EPM

PPM

SAFETY & HEALTH

REAL PROPERTY

PROJECT MANAGER

GDM-AE, Inc.

1308 NE 134th ST. SUITE A

VANCOUVER, WA 98685

P: 541.436.4723

WWW.GDM-AE.COM

STAMP

A u to d e s k D o c s /2

-0

U S

D A

W a p a to /2

-0

U S

D A

W a p a to A rc h

R

.r v t

A-010

DOOR & PARTITION TYPES & DETAILS

MA

SMW

RENOVATE LAB SPACE

TEMPERATE TREE FRUIT & VEGETABLE RESEARCH UNIT

100% DESIGN SUBMITTAL

25-005

5230 KONNOWAC PASS RD

WAPATO, WA 98951

03/19/2026

50% DESIGN SUBMITTAL

95% DESIGN SUBMITTAL

100% DESIGN SUBMITTAL

01/09/2026 03/02/2026 03/19/2026

3" = 1'-0"B3

HW-01 - 1 HR HEAD OF WALL UL HW-D-0001 PARALLEL TO DECK

FLUTES

3" = 1'-0"C3 HW-02 - 1 HR HEAD OF WALL PERPENDICULAR TO DECK FLUTES

6" = 1'-0"E5 TYPICAL DOOR FRAME @ STUD WALL Architectural - Door & Frame Schedule

ROOM

NUMBER NUMBER

DOOR FRAME

FIRE RATING REMARKS

SIZE

TYPE MAT TYPE MAT

DETAILS

WIDTH HEIGHT THK HEAD JAMB

416 85 3' - 0" 7' - 0" 1 3/4" C STL C HM E5/A-010 E5/A-010

Revisions: Date:

eshreve Stamp eshreve

H.1

CLEAN STOR

HARVEST

KITCHEN

STERILIZATION

COLD RM

SET UP

RESEARCH

LAB

COLD EC

RESEARCH

LAB

RESEARCH

LAB

CORR

VESTIBULE

MECHANICAL

ROOM

CORR

CORR

PHYSIO

BEHAVIOR LAB

INSECT ECOLOGY

LAB

WORK RM

CORR

A-141

F1

A-144

F1

RESEARCH

LAB

WARM EC

NOT IN SCOPE

OF WORK

NOT IN

SCOPE OF

WORK

NOT IN SCOPE

OF WORK

/8

13' - 11 3/8"

/8

/8

14' - 5 1/2" 10' - 6 3/4"5' - 6" 8' - 4 3/4"

BASE BID:

EXISTING CASEWORK

TO REMAIN

BASE BID:

REMOVE EXISTING

CASEWORK AND WALL

MOUNTED EQUIPMENT

1R

4R

5R

6R

7R

6R 8R

9R

7R

6R16R 5R4R 4R

5R

3R

3R

12R

12R

2R

2R

8R

7R 6R

4R

5R

12R 12R

12R

6R

4R

5R 4R

16R

2R

12R

12R

A4f

3R

19R

19R

C4

C4

A4

2R

12R

2R

A4f

12R

12R

12R 11R

11R

11R

25R 25R25R 26R

11R

19R

19R

11R

GENERAL SHEET NOTES

KEYED NOTES

1. FIELD VERIFY ALL EXISTING CONDITIONS, PRIOR TO START OF DEMOLITION.

BRING SIGNIFICANT DISCREPANCIES TO THE ATTENTION OF THE D.O.R. / OWNER

2. COORDINATE DEMOLITION PHASING AND SCHEDULE WITH THE OWNER.

3. THE OWNER RESERVES THE RIGHT TO HALT CONSTRUCTION ACTIVITY AT ANY

TIME DUE TO NOISE AND VIBRATION WHICH MIGHT AFFECT THE ONGOING USE

OF THE FACILITY.

4. PROTECT EXISTING CONSTRUCTION TO REMAIN FROM DAMAGE DURING

DEMOLITION, INCLUDING MECHANICAL & FIRE SUPPRESSION SYSTEMS.

5. OWNER WILL REMOVE ANY EXISTING FURNITURE AND MISC ITEMS IN ADVANCE

OF CONSTRUCTION. ALL REMAINING ITEMS TO BE REMOVED PER DRAWINGS

SHALL BE DISPOSED OF BY THE CONTRACTOR, OR SALVAGED TO WONER AS

NOTED.

6. EXISTING WALL MOUNTED DEVICES TO BE REMOVED UNLESS NOTED

OTHERWISE.

7. WHERE WALLS ARE INDICATED TO BE REMOVED, ANY UTILITIES FOUND WITHIN

SHALL BE REMOVED OR RE-ROUTED AS REQUIRED TO MAINTAIN THE

OPERATIONS OF ALL ADJACENT UNALTERED SPACES. WHEN UNEXPECTED

CONDITIONS ARISE NOTIFY THE DOR AND OWNER IMMEDIATELY.

8. REFER TO PLUMBING DRAWINGS FOR EXTENT OF REMOVAL AND INTENTIONS

FOR CAPPING OR RE-ROUTING OF EXISTING WATER, DRAIN, CONDENSATE,

STEAM, GAS AND SIMILAR LINES, WHERE FIXTURES ARE NOTED TO BE

REMOVED.

9. REFER TO MECHANICAL DRAWINGS FOR EXTENT OF DUCTWORK REMOVAL AND

INTENTIONS FOR CAPPING OR RE-ROUTING OF EXISTING DUCTWAORK WHERE

GRILL, DIFFUSER, AND REGISTER ARE NOTED TO BE REMOVED.

10. ALL DUCT OPENINGS INTO CONSTRUCTION AREAS SHALL BE COMPLETELY

SEALED TO PREVENT AIR CIRCULATION BETWEEN CONSTRUCTION ZONE AND

OCCUPIED AREAS VIA THE BUILDING HVAC SYSTEM.

11. REFER TO ELECTRICAL DRAWINGS FOR EXTENT OF CONDUIT AND CABLE

REMOVAL AND INTENTIONS FOR CIRCUTING AND RE-ROUTING OF EXISTING

ELECTRICAL WHERE DEVICES ARE NOTED TO BE REMOVED.

12. REMOVAL OF ASBESTOS CONTAINING AND OTHER POTENTIALLY HAZARDOUS

MATERIALS FROM THE BUILDING MUST FOLLOW STATE AND FEDERAL

REGULATIONS, AS WELL AS LOCAL LAWS WHEN APPLICABLE.

PLAN LEGEND

GRAPHIC DESCRIPTION PRIORITY

2 HR SMOKE / FIRE

2 HR SHAFT 2

NON RATED PARTITION

NEW CONSTRUCTION

EXISTING PARTITION

TO BE DEMOLISHED

1 HR SMOKE / FIRE 4

1 HR FIRE 5

HAZARDOUS 6

2 HR FIRE

10.1

J

H.1

HARVEST

RESEARCH

LAB

RESEARCH

LAB

CORR

PHYSIO

BEHAVIOR LAB

CORR

RESEARCH

LAB

NOT IN SCOPE

OF WORK

/8

/8

ADD ALTERNATE:

REMOVE EXISTING

CASEWORK AND

REPLACE.

SEE F1/A-144

8R

7R

5R

4R

6R

5R

4R

14R

6R

12R

12R12R

12R

10R

12R

12R 12R

PROJECT NO. DRAWING NO.

MA

FLS

ISSUE DATE

CHECKED BY

DRAWN BY

DRAWING TITLE

APPROVED:

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHASE

321 4 5 6 7 8 9 10

LOCATION

''1

NOT FOR CONSTRUCTION

FOR OFFICIAL USE ONLY (FOUO)

FULLY

SPRINKLERED

ARCHITECT/ENGINEER OF RECORD

Agricultural Research Service

U

USDA AGRICULTURAL RESEARCH SERVICE

AGRICULTURAL

RESEARCH SERVICE

USDA/ARS, PA

S D A

USDA A-E FIRM

EPM

PPM

SAFETY & HEALTH

REAL PROPERTY

PROJECT MANAGER

GDM-AE, Inc.

1308 NE 134th ST. SUITE A

VANCOUVER, WA 98685

P: 541.436.4723

WWW.GDM-AE.COM

STAMP

A u to d e s k D o c s /2

-0

U S

D A

W a p a to /2

-0

U S

D A

W a p a to A rc h

R

.r v t

A-100

FLOOR PLAN

MA

SMW

RENOVATE LAB SPACE

TEMPERATE TREE FRUIT & VEGETABLE RESEARCH UNIT

100% DESIGN SUBMITTAL

25-005

5230 KONNOWAC PASS RD

WAPATO, WA 98951

03/19/2026

50% DESIGN SUBMITTAL

95% DESIGN SUBMITTAL

100% DESIGN SUBMITTAL

01/09/2026 03/02/2026 03/19/2026

1/4" = 1'-0"F4 FLOOR PLAN - BASE BID

1R HOLLOW METAL DOOR AND FRAME, SEE DOOR SCHEDULE FOR ADDITIONAL

INFORMATION

2R INTERIOR PARTITION, SEE PARTITION TYPE FOR ADDITIONAL INFORMATION

3R METAL STUD PONY WALL AT CASEWORK ISLAND. PROVIDE BLOCKING FOR CABINET

ATTACHMENT, SEE PARTITION TYPE FOR ADDITIONAL INFORMATION

4R BASE CASEWORK, PAINTED STEEL

5R WALL MOUNTED PAINTED STEEL UPPER CASEWORK, PROVIDE WALL BLOCKING

6R EPOXY COUNTER TOP AND BACKSPLASH

7R EPOXY DROP IN SINK AND FAUCET - SEE PLUMBING FOR ADDITIONAL INFORMATION

8R EMERGENCY EYE AND FACE WASH, SEE PLUMBING DRAWINGS FOR ADDITIONAL

INFORMATION

9R OPEN PAINTED STEEL SHELVING WITH EDGE LIP

10R DRYING RACK, SEE EQUIPMENT SCHEDULE FOR ADDITIONAL INFORMATION

11R INTEGRAL COVED VINYL BASE

12R 5/8" TYPE X GYPSUM WALLBOARD OVER EXISTING METAL STUD FRAMING

14R HAND SANITIZER DISPENSER

16R RECESSED EMERGENCY SHOWER AND EYEWASH STATION SEE PLUMBING

DRAWINGS FOR ADDITIONAL INFORMATION

19R SHEET VINYL FLOORING

25R PATCH & PAINT EXISTING WALL & NEW INFILL PARTITION TO MATCH

26R NEW WALL BASE AT NEW INFILL PARTITION TO MATCH EXISTING

NORTH

0' 2' 4' 8'

1/4" = 1'-0"F2 FLOOR PLAN - ADD ALTERNATE

Revisions: Date:

eshreve Stamp eshreve

GYP. BD. CEILING SYSTEM

DOWN LIGHT FIXTURE

CEILING LEGEND

2 X 4 ACOUSTICAL LAY-IN CEILING SYSTEM.

1 X 4 LIGHT FIXTURE

SUPPLY AIR DIFFUSER

2 X 4 LIGHT FIXTURE

SPRINKLER

EDGE STRIP LIGHT FIXTURE

RETURN AIR VENT

GRAPHIC DESCRIPTION

10.1 11.1 13.1

J

H.1

CLEAN STOR

HARVEST

KITCHEN

STERILIZATION

COLD RM

SET UP

RESEARCH

LAB

COLD EC

RESEARCH

LAB

RESEARCH

LAB

CORR

VESTIBULE

MECHANICAL

ROOM

CORR

CORR

PHYSIO

BEHAVIOR LAB

INSECT ECOLOGY

LAB

WORK RM

CORR

RESEARCH

LAB

NOT IN SCOPE

OF WORK

NOT IN

SCOPE OF

WORK

NOT IN SCOPE

OF WORK

BASE BID:

EXISTING CEILING AND

LIGHTING TO REMAIN

BASE BID:

EXISTING CEILING AND

LIGHTING TO REMAIN

23R

17R

13R

21R

13R

17R

21R

21R

5R

5R

5R

5R

5R

5R

5R

5R

20R

17R

A4f 12R12R

12R

12R

12R

12R

12R

A4

21R

21R

12R

12R 12R 12R

12R

12R12R

12R

17R

GENERAL SHEET NOTES

KEYED NOTES

1. FIELD VERIFY ALL EXISTING CONDITIONS, PRIOR TO START OF DEMOLITION.

BRING SIGNIFICANT DISCREPANCIES TO THE ATTENTION OF THE D.O.R. / OWNER

2. COORDINATE DEMOLITION PHASING AND SCHEDULE WITH THE OWNER.

3. THE OWNER RESERVES THE RIGHT TO HALT CONSTRUCTION ACTIVITY AT ANY

TIME DUE TO NOISE AND VIBRATION WHICH MIGHT AFFECT THE ONGOING USE

OF THE FACILITY.

4. PROTECT EXISTING CONSTRUCTION TO REMAIN FROM DAMAGE DURING

DEMOLITION, INCLUDING MECHANICAL & FIRE SUPPRESSION SYSTEMS.

5. OWNER WILL REMOVE ANY EXISTING FURNITURE AND MISC ITEMS IN ADVANCE

OF CONSTRUCTION. ALL REMAINING ITEMS TO BE REMOVED PER DRAWINGS

SHALL BE DISPOSED OF BY THE CONTRACTOR, OR SALVAGED TO WONER AS

NOTED.

6. EXISTING WALL MOUNTED DEVICES TO BE REMOVED UNLESS NOTED

OTHERWISE.

7. WHERE WALLS ARE INDICATED TO BE REMOVED, ANY UTILITIES FOUND WITHIN

SHALL BE REMOVED OR RE-ROUTED AS REQUIRED TO MAINTAIN THE

OPERATIONS OF ALL ADJACENT UNALTERED SPACES. WHEN UNEXPECTED

CONDITIONS ARISE NOTIFY THE DOR AND OWNER IMMEDIATELY.

8. REFER TO PLUMBING DRAWINGS FOR EXTENT OF REMOVAL AND INTENTIONS

FOR CAPPING OR RE-ROUTING OF EXISTING WATER, DRAIN, CONDENSATE,

STEAM, GAS AND SIMILAR LINES, WHERE FIXTURES ARE NOTED TO BE

REMOVED.

9. REFER TO MECHANICAL DRAWINGS FOR EXTENT OF DUCTWORK REMOVAL AND

INTENTIONS FOR CAPPING OR RE-ROUTING OF EXISTING DUCTWAORK WHERE

GRILL, DIFFUSER, AND REGISTER ARE NOTED TO BE REMOVED.

10. ALL DUCT OPENINGS INTO CONSTRUCTION AREAS SHALL BE COMPLETELY

SEALED TO PREVENT AIR CIRCULATION BETWEEN CONSTRUCTION ZONE AND

OCCUPIED AREAS VIA THE BUILDING HVAC SYSTEM.

11. REFER TO ELECTRICAL DRAWINGS FOR EXTENT OF CONDUIT AND CABLE

REMOVAL AND INTENTIONS FOR CIRCUTING AND RE-ROUTING OF EXISTING

ELECTRICAL WHERE DEVICES ARE NOTED TO BE REMOVED.

12. REMOVAL OF ASBESTOS CONTAINING AND OTHER POTENTIALLY HAZARDOUS

MATERIALS FROM THE BUILDING MUST FOLLOW STATE AND FEDERAL

REGULATIONS, AS WELL AS LOCAL LAWS WHEN APPLICABLE.

PLAN LEGEND

GRAPHIC DESCRIPTION PRIORITY

2 HR SMOKE / FIRE

2 HR SHAFT 2

NON RATED PARTITION

NEW CONSTRUCTION

EXISTING PARTITION

TO BE DEMOLISHED

1 HR SMOKE / FIRE 4

1 HR FIRE 5

HAZARDOUS 6

2 HR FIRE

10.1

J

H.1

HARVEST

RESEARCH

LAB

RESEARCH

LAB

CORR

CORR

PHYSIO

BEHAVIOR LAB

CORR

RESEARCH

LAB

NOT IN SCOPE

OF WORK

ADD ALTERNATE:

PROVIDE NEW ACT

CEILING AND LIGHTING

ADD ALTERNATE:

PROVIDE NEW ACT

CEILING AND LIGHTING

12R

12R

17R

21R

5R

12R

5R

13R

12R

12R

17R

A4f 12R

12R

20R

21R

12R

20R

PROJECT NO. DRAWING NO.

MA

FLS

ISSUE DATE

CHECKED BY

DRAWN BY

DRAWING TITLE

APPROVED:

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHASE

321 4 5 6 7 8 9 10

LOCATION

''1

NOT FOR CONSTRUCTION

FOR OFFICIAL USE ONLY (FOUO)

FULLY

SPRINKLERED

ARCHITECT/ENGINEER OF RECORD

Agricultural Research Service

U

USDA AGRICULTURAL RESEARCH SERVICE

AGRICULTURAL

RESEARCH SERVICE

USDA/ARS, PA

S D A

USDA A-E FIRM

EPM

PPM

SAFETY & HEALTH

REAL PROPERTY

PROJECT MANAGER

GDM-AE, Inc.

1308 NE 134th ST. SUITE A

VANCOUVER, WA 98685

P: 541.436.4723

WWW.GDM-AE.COM

STAMP

A u to d e s k D o c s /2

-0

U S

D A

W a p a to /2

-0

U S

D A

W a p a to A rc h

R

.r v t

A-120

REFLECTED CEILING PLAN

MA

SMW

RENOVATE LAB SPACE

TEMPERATE TREE FRUIT & VEGETABLE RESEARCH UNIT

100% DESIGN SUBMITTAL

25-005

5230 KONNOWAC PASS RD

WAPATO, WA 98951

03/19/2026

50% DESIGN SUBMITTAL

95% DESIGN SUBMITTAL

100% DESIGN SUBMITTAL

01/09/2026 03/02/2026 03/19/2026

1/4" = 1'-0"F2 REFLECTED CEILING PLAN - BASE BID

5R WALL MOUNTED PAINTED STEEL UPPER CASEWORK, PROVIDE WALL BLOCKING

12R 5/8" TYPE X GYPSUM WALLBOARD OVER EXISTING METAL STUD FRAMING

13R SUSPENDED ACOUSTIC CEILING TILE SYSTEM

17R LIGHT FIXTURE, SEE ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION

20R MECHANICAL RETURN, SEE MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION

21R MECHANICAL SUPPLY, SEE MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION

23R ISLAND BENCH UMBILICAL, SEE EQUIPMENT SCHEDULE FOR ADDITIONAL INFORMATION

NORTH

0' 2' 4' 8'

1/4" = 1'-0"F1 REFLECTED CEILING PLAN - ADD ALTERNATE

Revisions: Date:

eshreve Stamp eshreve

10.1 11.1 13.1 14

L

J

H.1

22R

27R

22R

27R

GENERAL SHEET NOTES

KEYED NOTES

1. FIELD VERIFY ALL EXISTING CONDITIONS, PRIOR TO START OF DEMOLITION.

BRING SIGNIFICANT DISCREPANCIES TO THE ATTENTION OF THE D.O.R. / OWNER

2. COORDINATE DEMOLITION PHASING AND SCHEDULE WITH THE OWNER.

3. THE OWNER RESERVES THE RIGHT TO HALT CONSTRUCTION ACTIVITY AT ANY

TIME DUE TO NOISE AND VIBRATION WHICH MIGHT AFFECT THE ONGOING USE

OF THE FACILITY.

4. PROTECT EXISTING CONSTRUCTION TO REMAIN FROM DAMAGE DURING

DEMOLITION, INCLUDING MECHANICAL & FIRE SUPPRESSION SYSTEMS.

5. OWNER WILL REMOVE ANY EXISTING FURNITURE AND MISC ITEMS IN ADVANCE

OF CONSTRUCTION. ALL REMAINING ITEMS TO BE REMOVED PER DRAWINGS

SHALL BE DISPOSED OF BY THE CONTRACTOR, OR SALVAGED TO WONER AS

NOTED.

6. EXISTING WALL MOUNTED DEVICES TO BE REMOVED UNLESS NOTED

OTHERWISE.

7. WHERE WALLS ARE INDICATED TO BE REMOVED, ANY UTILITIES FOUND WITHIN

SHALL BE REMOVED OR RE-ROUTED AS REQUIRED TO MAINTAIN THE

OPERATIONS OF ALL ADJACENT UNALTERED SPACES. WHEN UNEXPECTED

CONDITIONS ARISE NOTIFY THE DOR AND OWNER IMMEDIATELY.

8. REFER TO PLUMBING DRAWINGS FOR EXTENT OF REMOVAL AND INTENTIONS

FOR CAPPING OR RE-ROUTING OF EXISTING WATER, DRAIN, CONDENSATE,

STEAM, GAS AND SIMILAR LINES, WHERE FIXTURES ARE NOTED TO BE

REMOVED.

9. REFER TO MECHANICAL DRAWINGS FOR EXTENT OF DUCTWORK REMOVAL AND

INTENTIONS FOR CAPPING OR RE-ROUTING OF EXISTING DUCTWAORK WHERE

GRILL, DIFFUSER, AND REGISTER ARE NOTED TO BE REMOVED.

10. ALL DUCT OPENINGS INTO CONSTRUCTION AREAS SHALL BE COMPLETELY

SEALED TO PREVENT AIR CIRCULATION BETWEEN CONSTRUCTION ZONE AND

OCCUPIED AREAS VIA THE BUILDING HVAC SYSTEM.

11. REFER TO ELECTRICAL DRAWINGS FOR EXTENT OF CONDUIT AND CABLE

REMOVAL AND INTENTIONS FOR CIRCUTING AND RE-ROUTING OF EXISTING

ELECTRICAL WHERE DEVICES ARE NOTED TO BE REMOVED.

12. REMOVAL OF ASBESTOS CONTAINING AND OTHER POTENTIALLY HAZARDOUS

MATERIALS FROM THE BUILDING MUST FOLLOW STATE AND FEDERAL

REGULATIONS, AS WELL AS LOCAL LAWS WHEN APPLICABLE.

PROJECT NO. DRAWING NO.

MA

FLS

ISSUE DATE

CHECKED BY

DRAWN BY

DRAWING TITLE

APPROVED:

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHASE

321 4 5 6 7 8 9 10

LOCATION

''1

NOT FOR CONSTRUCTION

FOR OFFICIAL USE ONLY (FOUO)

FULLY

SPRINKLERED

ARCHITECT/ENGINEER OF RECORD

Agricultural Research Service

U

USDA AGRICULTURAL RESEARCH SERVICE

AGRICULTURAL

RESEARCH SERVICE

USDA/ARS, PA

S D A

USDA A-E FIRM

EPM

PPM

SAFETY & HEALTH

REAL PROPERTY

PROJECT MANAGER

GDM-AE, Inc.

1308 NE 134th ST. SUITE A

VANCOUVER, WA 98685

P: 541.436.4723

WWW.GDM-AE.COM

STAMP

A u to d e s k D o c s /2

-0

U S

D A

W a p a to /2

-0

U S

D A

W a p a to A rc h

R

.r v t

A-130

ROOF PLAN

MA

SMW

RENOVATE LAB SPACE

TEMPERATE TREE FRUIT & VEGETABLE RESEARCH UNIT

100% DESIGN SUBMITTAL

25-005

5230 KONNOWAC PASS RD

WAPATO, WA 98951

03/19/2026

50% DESIGN SUBMITTAL

95% DESIGN SUBMITTAL

100% DESIGN SUBMITTAL

01/09/2026 03/02/2026 03/19/2026

3/16" = 1'-0"F2 ROOF PLAN

NORTH

0' 4' 8' 12'

22R NEW MECHANICAL EQUIPMENT, SEE MECHANICAL DRAWINGS FOR ADDITIONAL

INFORMATION

27R INSULATE & SEAL NEW FUME HOOD EXHAUST PENETRATION THROUGH ROOFING

SYSTEM

Revisions: Date:

eshreve Stamp eshreve

11.1

H.1

A-141

B5

A-141 B1

A-141 F4

RESEARCH

LAB

A-141

F8

COLD EC

NOT IN SCOPE

OF WORK

3' - 0 3/8" 5' - 6 7/8" 5' - 10 1/4" 6' - 10 1/8" 2'

5/

8"

4' - 1" 4' - 10" 1' - 11"

4 3/4"

4' - 0" 4' - 3" 1' - 11"

/4

STOOL

STOOL

STOOL

D7

D4

F7

STOOL

30x16x10

/2

/4

25x15x5(ABA)

LEVEL 1

0"

DU47ADA DA47ADA DU47ADALCDU47ADA

32' - 11"

1' - 11" 5' - 11" 3' - 11" 3' - 11" 3' - 11" 11' - 9"

DA47ADADW47ADA

1' - 4" 30' - 0"

B47H16B47H16E47M16E47M16E47M16B47H16A24HL16

KNEE SPACEKNEE SPACE

E47M16

13R

5R

4R

12R

11R 11R

12R

11R

12R

5R

12R

5R

4R

LEVEL 1

0"

DR47HAK24HAK24HDB47ADA

19' - 0 1/4"

/4

DQ47H

KNEE SPACE

1' - 4 1/2" 4' - 0" 4' - 0" 4' - 0" 3' - 3"

UMI240675

KNEE SPACE

3' - 5 1/2" 3' - 5 1/2"

OPS-REAGENT

RSS-244812

P2g P2g

11R

3R 3R

11R

4R

9R

9R 4R

23R

6R

8R

10R

13R

4R

LEVEL 1

0"

11.1

AG18ADA AG18ADA DB42ADA

E42M16

A24ML16

E42M16E30M16

6' - 0" 5' - 10 3/8" 5' - 6 3/4" 3' - 0 3/8"

DISHWASHER

2' - 0"

KNEE SPACE

2' - 11 3/4"

16R

2R

C4

11R

16R

5R

4R

10R

7R

24R15R

6R

12R

11R

5R

4R 6R

12R

11R12R12R 11R

13R 13R

12R

11R

13R

EMERGENCY

SHOWER

LEVEL 1

0"

DA47ADA

FUME HOOD

4' - 4 1/4" 4' - 4 1/2" 1' - 10"

DA47ADA

B47H16

5R

4R 6R

22R

12R

12R

1' - 4"4' - 10"4' - 4 3/4"

LEVEL 1

0"

DB47ADA

1' - 0 1/2"2' - 0"1' - 0 1/2"

UMI240675

4' - 1"

13R

23R

10R

8R6R

4R

7R

LEVEL 1

0"

DR47H DB47ADAAK24HAK24H DQ47H

19' - 0 1/4"

KNEE SPACE

/4

3' - 3" 4' - 0" 4' - 0" 4' - 0" 1' - 4 1/2" UMI240675

OPS-REAGENT

RSS-244812

KNEE SPACE

3' - 5 3/8" 3' - 5 3/8"

10R

8R

23R

6R

4R 11R

3R

9R

6R

11R

3R 4R

P2gP2g

13R

4R

4R 9R

7R

LEVEL 1

0"

DR47H

1' - 6 1/2" 1' - 0" 1' - 6 1/2"

/4

OPS-REAGENT

RSS-244812

4' - 1"

6R

4R

9R

13R

GENERAL SHEET NOTES

KEYED NOTES

1. FIELD VERIFY ALL EXISTING CONDITIONS, PRIOR TO START OF DEMOLITION.

BRING SIGNIFICANT DISCREPANCIES TO THE ATTENTION OF THE D.O.R. / OWNER

2. COORDINATE DEMOLITION PHASING AND SCHEDULE WITH THE OWNER.

3. THE OWNER RESERVES THE RIGHT TO HALT CONSTRUCTION ACTIVITY AT ANY

TIME DUE TO NOISE AND VIBRATION WHICH MIGHT AFFECT THE ONGOING USE

OF THE FACILITY.

4. PROTECT EXISTING CONSTRUCTION TO REMAIN FROM DAMAGE DURING

DEMOLITION, INCLUDING MECHANICAL & FIRE SUPPRESSION SYSTEMS.

5. OWNER WILL REMOVE ANY EXISTING FURNITURE AND MISC ITEMS IN ADVANCE

OF CONSTRUCTION. ALL REMAINING ITEMS TO BE REMOVED PER DRAWINGS

SHALL BE DISPOSED OF BY THE CONTRACTOR, OR SALVAGED TO WONER AS

NOTED.

6. EXISTING WALL MOUNTED DEVICES TO BE REMOVED UNLESS NOTED

OTHERWISE.

7. WHERE WALLS ARE INDICATED TO BE REMOVED, ANY UTILITIES FOUND WITHIN

SHALL BE REMOVED OR RE-ROUTED AS REQUIRED TO MAINTAIN THE

OPERATIONS OF ALL ADJACENT UNALTERED SPACES. WHEN UNEXPECTED

CONDITIONS ARISE NOTIFY THE DOR AND OWNER IMMEDIATELY.

8. REFER TO PLUMBING DRAWINGS FOR EXTENT OF REMOVAL AND INTENTIONS

FOR CAPPING OR RE-ROUTING OF EXISTING WATER, DRAIN, CONDENSATE,

STEAM, GAS AND SIMILAR LINES, WHERE FIXTURES ARE NOTED TO BE

REMOVED.

9. REFER TO MECHANICAL DRAWINGS FOR EXTENT OF DUCTWORK REMOVAL AND

INTENTIONS FOR CAPPING OR RE-ROUTING OF EXISTING DUCTWAORK WHERE

GRILL, DIFFUSER, AND REGISTER ARE NOTED TO BE REMOVED.

10. ALL DUCT OPENINGS INTO CONSTRUCTION AREAS SHALL BE COMPLETELY

SEALED TO PREVENT AIR CIRCULATION BETWEEN CONSTRUCTION ZONE AND

OCCUPIED AREAS VIA THE BUILDING HVAC SYSTEM.

11. REFER TO ELECTRICAL DRAWINGS FOR EXTENT OF CONDUIT AND CABLE

REMOVAL AND INTENTIONS FOR CIRCUTING AND RE-ROUTING OF EXISTING

ELECTRICAL WHERE DEVICES ARE NOTED TO BE REMOVED.

12. REMOVAL OF ASBESTOS CONTAINING AND OTHER POTENTIALLY HAZARDOUS

MATERIALS FROM THE BUILDING MUST FOLLOW STATE AND FEDERAL

REGULATIONS, AS WELL AS LOCAL LAWS WHEN APPLICABLE.

PROJECT NO. DRAWING NO.

MA

FLS

ISSUE DATE

CHECKED BY

DRAWN BY

DRAWING TITLE

APPROVED:

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHASE

321 4 5 6 7 8 9 10

LOCATION

''1

NOT FOR CONSTRUCTION

FOR OFFICIAL USE ONLY (FOUO)

FULLY

SPRINKLERED

ARCHITECT/ENGINEER OF RECORD

Agricultural Research Service

U

USDA AGRICULTURAL RESEARCH SERVICE

AGRICULTURAL

RESEARCH SERVICE

USDA/ARS, PA

S D A

USDA A-E FIRM

EPM

PPM

SAFETY & HEALTH

REAL PROPERTY

PROJECT MANAGER

GDM-AE, Inc.

1308 NE 134th ST. SUITE A

VANCOUVER, WA 98685

P: 541.436.4723

WWW.GDM-AE.COM

STAMP

A u to d e s k D o c s /2

-0

U S

D A

W a p a to /2

-0

U S

D A

W a p a to A rc h

R

.r v t

A-141

LAB 416 - EQUIPMENT PLAN & ELEVATIONS

MA

SMW

RENOVATE LAB SPACE

TEMPERATE TREE FRUIT & VEGETABLE RESEARCH UNIT

100% DESIGN SUBMITTAL

25-005

5230 KONNOWAC PASS RD

WAPATO, WA 98951

03/19/2026

50% DESIGN SUBMITTAL

95% DESIGN SUBMITTAL

100% DESIGN SUBMITTAL

01/09/2026 03/02/2026 03/19/2026

3/8" = 1'-0"F1 EQUIPMENT PLAN - LAB 416

1/2" = 1'-0"B1 LAB 416 - EAST ELEV

1/2" = 1'-0"F4 LAB 416 - ISLAND EAST ELEV

1/2" = 1'-0"B5 LAB 416 - SOUTH ELEV

1/2" = 1'-0"F8 LAB 416 - NORTH ELEV

1/2" = 1'-0"D7 LAB 416 - ISLAND NORTH ELEV

1/2" = 1'-0"D4 LAB 416 - ISLAND WEST ELEV

1/2" = 1'-0"F7 LAB 416 - ISLAND SOUTH ELEV

2R INTERIOR PARTITION, SEE PARTITION TYPE FOR ADDITIONAL INFORMATION

3R METAL STUD PONY WALL AT CASEWORK ISLAND. PROVIDE BLOCKING FOR CABINET

ATTACHMENT, SEE PARTITION TYPE FOR ADDITIONAL INFORMATION

4R BASE CASEWORK, PAINTED STEEL

5R WALL MOUNTED PAINTED STEEL UPPER CASEWORK, PROVIDE WALL BLOCKING

6R EPOXY COUNTER TOP AND BACKSPLASH

7R EPOXY DROP IN SINK AND FAUCET - SEE PLUMBING FOR ADDITIONAL INFORMATION

8R EMERGENCY EYE AND FACE WASH, SEE PLUMBING DRAWINGS FOR ADDITIONAL

INFORMATION

9R OPEN PAINTED STEEL SHELVING WITH EDGE LIP

10R DRYING RACK, SEE EQUIPMENT SCHEDULE FOR ADDITIONAL INFORMATION

11R INTEGRAL COVED VINYL BASE

12R 5/8" TYPE X GYPSUM WALLBOARD OVER EXISTING METAL STUD FRAMING

13R SUSPENDED ACOUSTIC CEILING TILE SYSTEM

15R PAPER TOWEL DISPENSER

16R RECESSED EMERGENCY SHOWER AND EYEWASH STATION SEE PLUMBING DRAWINGS

FOR ADDITIONAL INFORMATION

22R NEW MECHANICAL EQUIPMENT, SEE MECHANICAL DRAWINGS FOR ADDITIONAL

INFORMATION

23R…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .