Attachment 1- Bid Schedule.XLS
XLS spreadsheet 165 KB Posted
- Solicitation number
- W91248-20-Q-0006
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Overhead Door Type 2.jpg | JPG image | |
| Overhead Door Type 5.jpg | JPG image | |
| Overhead Door Type 4.jpg | JPG image | |
| W9124821Q0001-REV.pdf | ||
| Overhead Door Type 3.jpg | JPG image | |
| Overhead Door - Type 1.jpg | JPG image | |
| Amend 1- Overhead Door Solicitation.pdf | ||
| Attachment 2- Assessment Checklist.DOCX | DOCX document | |
| Attachment 4- Sectional Doors.pdf | ||
| Attachment 3- Misc Doors and Parts.pdf | ||
| Attachment 6- SCA 2015-4675.pdf | ||
| Attachment 5- Coiling Door.pdf | ||
| W91248-21-Q-0001- OH Door.pdf | ||
| Solicitation- PPQ.pdf |
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Summary
BASE
| Base Year: 2 JAN 2021 - 1 JAN 2022 | |||||
| ITEM NO | DESCRIPTION | QUANTITY | UNIT | UNIT PRICE | AMOUNT |
| 0001 | Perfrom an assessment that includes the Maintenance and minor repairs listed in Technical Exhibit 1 to determine repairs that may be required | 50 | Lump Sum | $ - 0 | |
| Remove existing and Install New Manually Operated Sectional Door complete to include the following cables, torsion bar,springs, drums, brackets, locks, tracks, door stops, vision glass, weather stripping and other hardware items needed for a complete and functional door unit. To include matching paint. | |||||
| 0002 | Non-Insulated - Manually Operated Sectional Door | 1,350 | Square Foot | $ - 0 | |
| 0003 | Insulated – Manually Operated Sectional Door | 375 | Square Foot | $ - 0 | |
| Remove existing and Install New Power Operated Sectional Door complete, to include the following: cables, torsion gar, springs, drums, brackets, tracks, door stops, vision glass, locks, weather stripping, gears, transmission, sprockets, door sections, electrical operator of equal or greater horsepower, electrical connection from operator, wiring to existing push button control station with "HOLD TO CLOSE" wiring option, and any functional hardware items needed for a complete door unit, to include matching paint. | |||||
| 0004 | Non-Insulated Sectional Door Complete (power-operated) | 336 | Square Foot | $ - 0 | |
| 0005 | Insulated Sectional Door Power Operated | 336 | Square Foot | $ - 0 | |
| Remove existing and Install new sectional metal overhead door parts. Paint door sections to match existing | |||||
| 0006 | Individual Door Sections(Non-Insulated) | 500 | Square Foot | $ - 0 | |
| 0007 | Individual Door Sections Insulated | 240 | Square Foot | $ - 0 | |
| 0008 | Vision Glass | 15 | Square Foot | $ - 0 | |
| Remove existing door and Install new chain hoist operated metal roll-up drum type, Door Complete to include the following: slats, windlocks, stops, bells-mouths, tracks, guides, bracing, gears, sprockets, chains, bearings, hoist assembly , drum covers, locking devices and other necessary hardware items for a complete functional door unit, to include matching paint | |||||
| 0009 | Non-Insulated - Chain hoist Operated Roll-Up Door | 540 | Square Foot | $ - 0 | |
| 0010 | Insulated - Chain Hoist Operated Roll-Up Door | 540 | Square Foot | $ - 0 | |
| Remove existing Door and Install New Power operated metal roll-up drum type, Door Complete to include: slats, windlocks, stops, bell0mouths, tracks, guides, bracings, gears, transmission, all sprockets, all chains, torsion tube springs, angles, weather strippings, brackets, bearings, drum, covers, lockings devices, electrical operator of equal or greater horsepower, electric connection from operator, wiring to existing push button control station with "HOLD TO CLOSE" wiring option, , replace of all necessary hardware items for a complete and functional door unit to include matching paint. | |||||
| 0011 | Non-Insulated - Power Operated Roll-Up Door | 540 | Square Foot | $ - 0 | |
| 0012 | Insulated Power Operated Roll-Up Door | 540 | Square Foot | $ - 0 | |
| 0013 | Remove existing Door and install New Chain Hoist Operated metal roll-up type UL Listed Fire Door of specified hour rating Complete to include the following: slats, windlocks, stops, bell0mouths, tracks, guides, bracings, gears, transmission, all sprockets, all chains, torsion tube springs, angles, weather strippings, brackets, bearings, drum, covers, lockings devices, electrical operator of equal or greater horsepower, electric connection from operator, wiring to existing push button control station with "HOLD TO CLOSE" wiring option, , replace of all necessary hardware items for a complete and functional door unit to include matching paint. | 300 | Square Foot | $ - 0 | |
| Replace the following Parts on existing roll-up drum type doors. Paint to match existing. | |||||
| 0014 | Non-Insulated galvanized slats with continuous wind locks to match the existing | 200 | Square Foot | $ - 0 | |
| 0015 | Insulated galvanized steel slats with continuous wind locks to match the existing. | 200 | Square Foot | $ - 0 | |
| 0016 | Complete Non-Insulated Curtain Assembly with wind wind locks and end locks to match the existing | 405 | Square Foot | $ - 0 | |
| 0017 | Complete Insulated curtain assembly with wind locks and end locks to match the existing | 405 | Square Foot | $ - 0 | |
| 0018 | Door Adjustments on ALL DOORS Include the following items as applicable to the individual door. Tighten all hardware, bolts, and track brackets; straighten bent tracks, struts and door guide wall angles; lubricate all hinged hardware and rollers; adjust torsion spring tension, struts, cable drums, door and door locks. Applicable to all door types. | 20 | Each | $ - 0 | |
| Remove the existing and install the following new parts and/or hardware, including necessary door adjustment on all insulated and non-insulated roll-up and sectional doors as applicable, Paint to match existing | |||||
| 0019 | Add oil to gear reducer | 10 | Each | $ - 0 | |
| 0020 | Torsion Bar (Solid Shaft) | 40 | Linear Foot | $ - 0 | |
| 0021 | Torsion Bar (Hollow Shaft) | 20 | Linear Foot | $ - 0 | |
| 0022 | Torsion Spring | 10 | Linear Foot | $ - 0 | |
| 0023 | Track (Overhead Doors) 2" or 3" as required | 200 | Linear Foot | $ - 0 | |
| 0024 | 3/16" Lift Cable | 200 | Linear Foot | $ - 0 | |
| 0025 | 3/8" Nylon Pull Rope | 200 | Linear Foot | $ - 0 | |
| 0026 | Replace Overhead Door Locking Devices | 10 | Each | $ - 0 | |
| 0027 | Molded rubber weather strip (bottom) | 150 | Linear Foot | $ - 0 | |
| 0028 | Angle guide weatherstrip (Vertical) | 150 | Linear Foot | $ - 0 | |
| 0029 | Lintel Weatherseal, 3-1/2" aluminum retainer with 3" minimum heavy brush | 150 | Linear Foot | $ - 0 | |
| 0030 | Wind Guides (Match existing material) | 35 | Linear Foot | $ - 0 | |
| 0031 | Wind locks/End locks Match existing | 50 | Each | $ - 0 | |
| 0032 | 2"x2"x1/8" Angle Iron | 50 | Linear Foot | $ - 0 | |
| 0033 | 1-1/4"x2"x1/8" Angle Iron | 50 | Linear Foot | $ - 0 | |
| 0034 | Anchor brackets for torsion assembly | 10 | Each | $ - 0 | |
| 0035 | Adjustable Track Brackerts | 10 | Each | $ - 0 | |
| 0036 | Pressure treated #2 or better wood door Jamb molding and trim to match the existing. Paint to match existing | 100 | Board Feet | $ - 0 | |
| 0037 | Metal jambs channels and/or angles to match existing | 50 | Linear Foot | $ - 0 | |
| 0038 | Replacement Chain for chain hoist | 50 | Linear Foot | $ - 0 | |
| 0039 | Door Guide wall angles roll-up doors | 20 | Linear Foot | $ - 0 | |
| 0040 | Replace safety edge for power operated doors. Include removal and reinstallation doors. Include removal and reinstallation of existing safety switch. | 60 | Linear Foot | $ - 0 | |
| 0041 | Reconfigure control panel (to require the contstant depression of the push-button in the down and or both directions. | 10 | Each | $ - 0 | |
| 0042 | Center Hinge | 20 | Each | $ - 0 | |
| 0043 | Overhead Door Top Fixture | 20 | Each | $ - 0 | |
| 0044 | Overhead Door Bottom Fixture | 20 | Each | $ - 0 | |
| 0045 | End Hinge | 20 | Each | $ - 0 | |
| 0046 | 2" short stem roller | 20 | Each | $ - 0 | |
| 0047 | 2" Long stem roller | 20 | Each | $ - 0 | |
| 0048 | 3" short stem roller | 10 | Each | $ - 0 | |
| 0049 | 3" long stem roller | 10 | Each | $ - 0 | |
| 0050 | Replace flange bearing on end bracket (Drive End) | 4 | Each | $ - 0 | |
| 0051 | Replace Flange Bearing in the Barrel Tension End | 4 | Each | $ - 0 | |
| Replace the following miscellaneous parts to match existing | |||||
| 0052 | Replace chain hoist mechanism complete with chain for regular door | 3 | Each | $ - 0 | |
| 0053 | Replace chain hoist mechanism complete with chain for fire door | 1 | Each | $ - 0 | |
| 0054 | Replace steel rolling curtain door hood | 60 | Linear Foot | $ - 0 | |
| 0055 | Replace torsion tube and spring assembly, complete | 60 | Linear Foot | $ - 0 | |
| 0056 | Replace Inertia Brake (below a 100 SF door) | 1 | Each | $ - 0 | |
| 0057 | Replace Inertia Brake (100 SF to 300 SF Door) | 1 | Each | $ - 0 | |
| 0058 | Replace Inertia Brake (Above a 300 SF Door) | 2 | Each | $ - 0 | |
| 0059 | Replace existing electric operator complete to include the following: Electric motor, transmission gear box, brake and re-connection to the existing electrical supply and pushbutton stations. | 5 | Each | $ - 0 | |
| 0060 | Replace Power Operator Mounting Bracket | 4 | Each | $ - 0 | |
| 0061 | Replace Limit Switch, to match existing, to include adjustments for proper door travel | 2 | Each | $ - 0 | |
| 0062 | Adjust limit switches for proper door travel | 2 | Each | $ - 0 | |
| 0063 | Replace electric cord from electric edge to operator switch to match existing | 50 | Linear Foot | $ - 0 | |
| 0064 | Reattach existing Electric Cord | 5 | Each | $ - 0 | |
| 0065 | Replace motor operator drive chain to match existing, to include limit switch adjustment | 5 | Each | $ - 0 | |
| 0066 | Replace motor drive chain sprockets to match existing. To include limit switch adjustment. | 5 | Each | $ - 0 | |
| 0067 | Replace curtain barrel drive chain sprockets to match existing, to include limit switch adjustment | 5 | Each | $ - 0 | |
| 0068 | Replace spur gear for chain hoist operation | 4 | Each | $ - 0 | |
| 0069 | Replace door stops to match existing | 20 | Each | $ - 0 | |
| 0070 | Replace push-button control station to match existing, to include wiring and reconnection to existing controls. | 2 | Each | $ - 0 | |
| 0071 | Replace operator control circuit board complete to match existing. Wiring to existing electric is included. | 2 | Each | $ - 0 | |
| 0072 | Replace headplate (below a 100 SF Door) | 1 | Each | $ - 0 | |
| 0073 | Replace headplate (100 SF to 300 SF Door | 2 | Each | $ - 0 | |
| 0074 | Replace headplate (above 300 SF Door) | 2 | Each | $ - 0 | |
| 0075 | Replace Barrel Shaft | 1 | Each | $ - 0 | |
| 0076 | Replace Barrel Shaft to include disassembly and re-assembly of door (100 SF to 300 SF door) | 2 | Each | $ - 0 | |
| 0077 | Replace Barrel Shaft to include disassembly and re-assembly of door (abobe a 300 SF door) | 2 | Each | $ - 0 | |
| 0078 | Replace final drive component "gearbox" on door operator to include coupling element or belt | 1 | Each | $ - 0 | |
| 0079 | Replace dual contactor in door operator of equal or better rating than the original | 2 | Each | $ - 0 | |
| 0080 | Reset activated or locked-up inertia brake | 1 | Each | $ - 0 | |
| 0081 | Replace existing sprocket with a #50-Series-84 Tooth or larger on drum or Driven Shaft | 1 | Each | $ - 0 | |
| 0082 | Replace existing sprocket with a #60 series-12 tooth on the Operator or Driver shaft chain | 1 | Each | $ - 0 | |
| 0083 | Replace existing main drive chain with a #60 series chain | 1 | Each | $ - 0 | |
| 0084 | Install a torque limiter on door operator | 1 | Each | $ - 0 | |
| Furnish and install a double accordion type gate in front of door for access control when the door is open. Shall have galvanized finish and shall have a pad-lockable tab or hasp | |||||
| 0085 | Install 6'-6" double accordion galvanize gate at 8'wide door | 1 | Each | $ - 0 | |
| $ - 0 |
OPTION-1
| Option 1: 2 JAN 2022 - 1 JAN 2023 | |||||
| ITEM NO | DESCRIPTION | QUANTITY | UNIT | UNIT PRICE | AMOUNT |
| 1001 | Perfrom an assessment that includes the Maintenance and minor repairs listed in Technical Exhibit 1 to determine repairs that may be required | 50 | Lump Sum | $ - 0 | $ - 0 |
| Remove existing and Install New Manually Operated Sectional Door complete to include the following cables, torsion bar,springs, drums, brackets, locks, tracks, door stops, vision glass, weather stripping and other hardware items needed for a complete and functional door unit. To include matching paint. | |||||
| 1002 | Non-Insulated - Manually Operated Sectional Door | 1,350 | Square Foot | $ - 0 | $ - 0 |
| 1003 | Insulated – Manually Operated Sectional Door | 375 | Square Foot | $ - 0 | $ - 0 |
| Remove existing and Install New Power Operated Sectional Door complete, to include the following: cables, torsion gar, springs, drums, brackets, tracks, door stops, vision glass, locks, weather stripping, gears, transmission, sprockets, door sections, electrical operator of equal or greater horsepower, electrical connection from operator, wiring to existing push button control station with "HOLD TO CLOSE" wiring option, and any functional hardware items needed for a complete door unit, to include matching paint. | |||||
| 1004 | Non-Insulated Sectional Door Complete (power-operated) | 336 | Square Foot | $ - 0 | $ - 0 |
| 1005 | Insulated Sectional Door Power Operated | 336 | Square Foot | $ - 0 | $ - 0 |
| Remove existing and Install new sectional metal overhead door parts. Paint door sections to match existing | |||||
| 1006 | Individual Door Sections(Non-Insulated) | 500 | Square Foot | $ - 0 | $ - 0 |
| 1007 | Individual Door Sections Insulated | 240 | Square Foot | $ - 0 | $ - 0 |
| 1008 | Vision Glass | 15 | Square Foot | $ - 0 | $ - 0 |
| Remove existing door and Install new chain hoist operated metal roll-up drum type, Door Complete to include the following: slats, windlocks, stops, bells-mouths, tracks, guides, bracing, gears, sprockets, chains, bearings, hoist assembly , drum covers, locking devices and other necessary hardware items for a complete functional door unit, to include matching paint | |||||
| 1009 | Non-Insulated - Chain hoist Operated Roll-Up Door | 540 | Square Foot | $ - 0 | $ - 0 |
| 1010 | Insulated - Chain Hoist Operated Roll-Up Door | 540 | Square Foot | $ - 0 | $ - 0 |
| Remove existing Door and Install New Power operated metal roll-up drum type, Door Complete to include: slats, windlocks, stops, bell0mouths, tracks, guides, bracings, gears, transmission, all sprockets, all chains, torsion tube springs, angles, weather strippings, brackets, bearings, drum, covers, lockings devices, electrical operator of equal or greater horsepower, electric connection from operator, wiring to existing push button control station with "HOLD TO CLOSE" wiring option, , replace of all necessary hardware items for a complete and functional door unit to include matching paint. | |||||
| 1011 | Non-Insulated - Power Operated Roll-Up Door | 540 | Square Foot | $ - 0 | $ - 0 |
| 1012 | Insulated Power Operated Roll-Up Door | 540 | Square Foot | $ - 0 | $ - 0 |
| 1013 | Remove existing Door and install New Chain Hoist Operated metal roll-up type UL Listed Fire Door of specified hour rating Complete to include the following: slats, windlocks, stops, bell0mouths, tracks, guides, bracings, gears, transmission, all sprockets, all chains, torsion tube springs, angles, weather strippings, brackets, bearings, drum, covers, lockings devices, electrical operator of equal or greater horsepower, electric connection from operator, wiring to existing push button control station with "HOLD TO CLOSE" wiring option, , replace of all necessary hardware items for a complete and functional door unit to include matching paint. | 300 | Square Foot | $ - 0 | $ - 0 |
| Replace the following Parts on existing roll-up drum type doors. Paint to match existing. | |||||
| 1014 | Non-Insulated galvanized slats with continuous wind locks to match the existing | 200 | Square Foot | $ - 0 | $ - 0 |
| 1015 | Insulated galvanized steel slats with continuous wind locks to match the existing. | 200 | Square Foot | $ - 0 | $ - 0 |
| 1016 | Complete Non-Insulated Curtain Assembly with wind wind locks and end locks to match the existing | 405 | Square Foot | $ - 0 | $ - 0 |
| 1017 | Complete Insulated curtain assembly with wind locks and end locks to match the existing | 405 | Square Foot | $ - 0 | $ - 0 |
| 1018 | Door Adjustments on ALL DOORS Include the following items as applicable to the individual door. Tighten all hardware, bolts, and track brackets; straighten bent tracks, struts and door guide wall angles; lubricate all hinged hardware and rollers; adjust torsion spring tension, struts, cable drums, door and door locks. Applicable to all door types. | 20 | Each | $ - 0 | $ - 0 |
| Remove the existing and install the following new parts and/or hardware, including necessary door adjustment on all insulated and non-insulated roll-up and sectional doors as applicable, Paint to match existing | |||||
| 1019 | Add oil to gear reducer | 10 | Each | $ - 0 | $ - 0 |
| 1010 | Torsion Bar (Solid Shaft) | 40 | Linear Foot | $ - 0 | $ - 0 |
| 1021 | Torsion Bar (Hollow Shaft) | 20 | Linear Foot | $ - 0 | $ - 0 |
| 1022 | Torsion Spring | 10 | Linear Foot | $ - 0 | $ - 0 |
| 1023 | Track (Overhead Doors) 2" or 3" as required | 200 | Linear Foot | $ - 0 | $ - 0 |
| 1024 | 3/16" Lift Cable | 200 | Linear Foot | $ - 0 | $ - 0 |
| 1025 | 3/8" Nylon Pull Rope | 200 | Linear Foot | $ - 0 | $ - 0 |
| 1026 | Replace Overhead Door Locking Devices | 10 | Each | $ - 0 | $ - 0 |
| 1027 | Molded rubber weather strip (bottom) | 150 | Linear Foot | $ - 0 | $ - 0 |
| 1028 | Angle guide weatherstrip (Vertical) | 150 | Linear Foot | $ - 0 | $ - 0 |
| 1029 | Lintel Weatherseal, 3-1/2" aluminum retainer with 3" minimum heavy brush | 150 | Linear Foot | $ - 0 | $ - 0 |
| 1030 | Wind Guides (Match existing material) | 35 | Linear Foot | $ - 0 | $ - 0 |
| 1031 | Wind locks/End locks Match existing | 50 | Each | $ - 0 | $ - 0 |
| 1032 | 2"x2"x1/8" Angle Iron | 50 | Linear Foot | $ - 0 | $ - 0 |
| 1033 | 1-1/4"x2"x1/8" Angle Iron | 50 | Linear Foot | $ - 0 | $ - 0 |
| 1034 | Anchor brackets for torsion assembly | 10 | Each | $ - 0 | $ - 0 |
| 1035 | Adjustable Track Brackerts | 10 | Each | $ - 0 | $ - 0 |
| 1036 | Pressure treated #2 or better wood door Jamb molding and trim to match the existing. Paint to match existing | 100 | Board Feet | $ - 0 | $ - 0 |
| 1037 | Metal jambs channels and/or angles to match existing | 50 | Linear Foot | $ - 0 | $ - 0 |
| 1038 | Replacement Chain for chain hoist | 50 | Linear Foot | $ - 0 | $ - 0 |
| 1039 | Door Guide wall angles roll-up doors | 20 | Linear Foot | $ - 0 | $ - 0 |
| 1040 | Replace safety edge for power operated doors. Include removal and reinstallation doors. Include removal and reinstallation of existing safety switch. | 60 | Linear Foot | $ - 0 | $ - 0 |
| 1041 | Reconfigure control panel (to require the contstant depression of the push-button in the down and or both directions. | 10 | Each | $ - 0 | $ - 0 |
| 1042 | Center Hinge | 20 | Each | $ - 0 | $ - 0 |
| 1043 | Overhead Door Top Fixture | 20 | Each | $ - 0 | $ - 0 |
| 1044 | Overhead Door Bottom Fixture | 20 | Each | $ - 0 | $ - 0 |
| 1045 | End Hinge | 20 | Each | $ - 0 | $ - 0 |
| 1046 | 2" short stem roller | 20 | Each | $ - 0 | $ - 0 |
| 1047 | 2" Long stem roller | 20 | Each | $ - 0 | $ - 0 |
| 1048 | 3" short stem roller | 10 | Each | $ - 0 | $ - 0 |
| 1049 | 3" long stem roller | 10 | Each | $ - 0 | $ - 0 |
| 1050 | Replace flange bearing on end bracket (Drive End) | 4 | Each | $ - 0 | $ - 0 |
| 1051 | Replace Flange Bearing in the Barrel Tension End | 4 | Each | $ - 0 | $ - 0 |
| Replace the following miscellaneous parts to match existing | |||||
| 1052 | Replace chain hoist mechanism complete with chain for regular door | 3 | Each | $ - 0 | $ - 0 |
| 1053 | Replace chain hoist mechanism complete with chain for fire door | 1 | Each | $ - 0 | $ - 0 |
| 1054 | Replace steel rolling curtain door hood | 60 | Linear Foot | $ - 0 | $ - 0 |
| 1055 | Replace torsion tube and spring assembly, complete | 60 | Linear Foot | $ - 0 | $ - 0 |
| 1056 | Replace Inertia Brake (below a 100 SF door) | 1 | Each | $ - 0 | $ - 0 |
| 1057 | Replace Inertia Brake (100 SF to 300 SF Door) | 1 | Each | $ - 0 | $ - 0 |
| 1058 | Replace Inertia Brake (Above a 300 SF Door) | 2 | Each | $ - 0 | $ - 0 |
| 1059 | Replace existing electric operator complete to include the following: Electric motor, transmission gear box, brake and re-connection to the existing electrical supply and pushbutton stations. | 5 | Each | $ - 0 | $ - 0 |
| 1060 | Replace Power Operator Mounting Bracket | 4 | Each | $ - 0 | $ - 0 |
| 1061 | Replace Limit Switch, to match existing, to include adjustments for proper door travel | 2 | Each | $ - 0 | $ - 0 |
| 1062 | Adjust limit switches for proper door travel | 2 | Each | $ - 0 | $ - 0 |
| 1063 | Replace electric cord from electric edge to operator switch to match existing | 50 | Linear Foot | $ - 0 | $ - 0 |
| 1064 | Reattach existing Electric Cord | 5 | Each | $ - 0 | $ - 0 |
| 1065 | Replace motor operator drive chain to match existing, to include limit switch adjustment | 5 | Each | $ - 0 | $ - 0 |
| 1066 | Replace motor drive chain sprockets to match existing. To include limit switch adjustment. | 5 | Each | $ - 0 | $ - 0 |
| 1067 | Replace curtain barrel drive chain sprockets to match existing, to include limit switch adjustment | 5 | Each | $ - 0 | $ - 0 |
| 1068 | Replace spur gear for chain hoist operation | 4 | Each | $ - 0 | $ - 0 |
| 1069 | Replace door stops to match existing | 20 | Each | $ - 0 | $ - 0 |
| 1070 | Replace push-button control station to match existing, to include wiring and reconnection to existing controls. | 2 | Each | $ - 0 | $ - 0 |
| 1071 | Replace operator control circuit board complete to match existing. Wiring to existing electric is included. | 2 | Each | $ - 0 | $ - 0 |
| 1072 | Replace headplate (below a 100 SF Door) | 1 | Each | $ - 0 | $ - 0 |
| 1073 | Replace headplate (100 SF to 300 SF Door | 2 | Each | $ - 0 | $ - 0 |
| 1074 | Replace headplate (above 300 SF Door) | 2 | Each | $ - 0 | $ - 0 |
| 1075 | Replace Barrel Shaft | 1 | Each | $ - 0 | $ - 0 |
| 1076 | Replace Barrel Shaft to include disassembly and re-assembly of door (100 SF to 300 SF door) | 2 | Each | $ - 0 | $ - 0 |
| 1077 | Replace Barrel Shaft to include disassembly and re-assembly of door (abobe a 300 SF door) | 2 | Each | $ - 0 | $ - 0 |
| 1078 | Replace final drive component "gearbox" on door operator to include coupling element or belt | 1 | Each | $ - 0 | $ - 0 |
| 1079 | Replace dual contactor in door operator of equal or better rating than the original | 2 | Each | $ - 0 | $ - 0 |
| 1080 | Reset activated or locked-up inertia brake | 1 | Each | $ - 0 | $ - 0 |
| 1081 | Replace existing sprocket with a #50-Series-84 Tooth or larger on drum or Driven Shaft | 1 | Each | $ - 0 | $ - 0 |
| 1082 | Replace existing sprocket with a #60 series-12 tooth on the Operator or Driver shaft chain | 1 | Each | $ - 0 | $ - 0 |
| 1083 | Replace existing main drive chain with a #60 series chain | 1 | Each | $ - 0 | $ - 0 |
| 1084 | Install a torque limiter on door operator | 1 | Each | $ - 0 | $ - 0 |
| Furnish and install a double accordion type gate in front of door for access control when the door is open. Shall have galvanized finish and shall have a pad-lockable tab or hasp | |||||
| 1085 | Install 6'-6" double accordion galvanize gate at 8'wide door | 1 | Each | $ - 0 | $ - 0 |
| $ - 0 |
OPTION-2
| ITEM NO | DESCRIPTION | QUANTITY | UNIT | UNIT PRICE | AMOUNT |
| 2001 | Perfrom an assessment that includes the Maintenance and minor repairs listed in Technical Exhibit 1 to determine repairs that may be required | 50 | Lump Sum | $ - 0 | $ - 0 |
| Remove existing and Install New Manually Operated Sectional Door complete to include the following cables, torsion bar,springs, drums, brackets, locks, tracks, door stops, vision glass, weather stripping and other hardware items needed for a complete and functional door unit. To include matching paint. | |||||
| 2002 | Non-Insulated - Manually Operated Sectional Door | 1,350 | Square Foot | $ - 0 | $ - 0 |
| 2003 | Insulated – Manually Operated Sectional Door | 375 | Square Foot | $ - 0 | $ - 0 |
| Remove existing and Install New Power Operated Sectional Door complete, to include the following: cables, torsion gar, springs, drums, brackets, tracks, door stops, vision glass, locks, weather stripping, gears, transmission, sprockets, door sections, electrical operator of equal or greater horsepower, electrical connection from operator, wiring to existing push button control station with "HOLD TO CLOSE" wiring option, and any functional hardware items needed for a complete door unit, to include matching paint. | |||||
| 2004 | Non-Insulated Sectional Door Complete (power-operated) | 336 | Square Foot | $ - 0 | $ - 0 |
| 2005 | Insulated Sectional Door Power Operated | 336 | Square Foot | $ - 0 | $ - 0 |
| Remove existing and Install new sectional metal overhead door parts. Paint door sections to match existing | |||||
| 2006 | Individual Door Sections(Non-Insulated) | 500 | Square Foot | $ - 0 | $ - 0 |
| 2007 | Individual Door Sections Insulated | 240 | Square Foot | $ - 0 | $ - 0 |
| 2008 | Vision Glass | 15 | Square Foot | $ - 0 | $ - 0 |
| Remove existing door and Install new chain hoist operated metal roll-up drum type, Door Complete to include the following: slats, windlocks, stops, bells-mouths, tracks, guides, bracing, gears, sprockets, chains, bearings, hoist assembly , drum covers, locking devices and other necessary hardware items for a complete functional door unit, to include matching paint | |||||
| 2009 | Non-Insulated - Chain hoist Operated Roll-Up Door | 540 | Square Foot | $ - 0 | $ - 0 |
| 2010 | Insulated - Chain Hoist Operated Roll-Up Door | 540 | Square Foot | $ - 0 | $ - 0 |
| Remove existing Door and Install New Power operated metal roll-up drum type, Door Complete to include: slats, windlocks, stops, bell0mouths, tracks, guides, bracings, gears, transmission, all sprockets, all chains, torsion tube springs, angles, weather strippings, brackets, bearings, drum, covers, lockings devices, electrical operator of equal or greater horsepower, electric connection from operator, wiring to existing push button control station with "HOLD TO CLOSE" wiring option, , replace of all necessary hardware items for a complete and functional door unit to include matching paint. | |||||
| 2011 | Non-Insulated - Power Operated Roll-Up Door | 540 | Square Foot | $ - 0 | $ - 0 |
| 2012 | Insulated Power Operated Roll-Up Door | 540 | Square Foot | $ - 0 | $ - 0 |
| 2013 | Remove existing Door and install New Chain Hoist Operated metal roll-up type UL Listed Fire Door of specified hour rating Complete to include the following: slats, windlocks, stops, bell0mouths, tracks, guides, bracings, gears, transmission, all sprockets, all chains, torsion tube springs, angles, weather strippings, brackets, bearings, drum, covers, lockings devices, electrical operator of equal or greater horsepower, electric connection from operator, wiring to existing push button control station with "HOLD TO CLOSE" wiring option, , replace of all necessary hardware items for a complete and functional door unit to include matching paint. | 300 | Square Foot | $ - 0 | $ - 0 |
| Replace the following Parts on existing roll-up drum type doors. Paint to match existing. | |||||
| 2014 | Non-Insulated galvanized slats with continuous wind locks to match the existing | 200 | Square Foot | $ - 0 | $ - 0 |
| 2015 | Insulated galvanized steel slats with continuous wind locks to match the existing. | 200 | Square Foot | $ - 0 | $ - 0 |
| 2016 | Complete Non-Insulated Curtain Assembly with wind wind locks and end locks to match the existing | 405 | Square Foot | $ - 0 | $ - 0 |
| 2017 | Complete Insulated curtain assembly with wind locks and end locks to match the existing | 405 | Square Foot | $ - 0 | $ - 0 |
| 2018 | Door Adjustments on ALL DOORS Include the following items as applicable to the individual door. Tighten all hardware, bolts, and track brackets; straighten bent tracks, struts and door guide wall angles; lubricate all hinged hardware and rollers; adjust torsion spring tension, struts, cable drums, door and door locks. Applicable to all door types. | 20 | Each | $ - 0 | $ - 0 |
| Remove the existing and install the following new parts and/or hardware, including necessary door adjustment on all insulated and non-insulated roll-up and sectional doors as applicable, Paint to match existing | |||||
| 2019 | Add oil to gear reducer | 10 | Each | $ - 0 | $ - 0 |
| 2020 | Torsion Bar (Solid Shaft) | 40 | Linear Foot | $ - 0 | $ - 0 |
| 2021 | Torsion Bar (Hollow Shaft) | 20 | Linear Foot | $ - 0 | $ - 0 |
| 2022 | Torsion Spring | 10 | Linear Foot | $ - 0 | $ - 0 |
| 2023 | Track (Overhead Doors) 2" or 3" as required | 200 | Linear Foot | $ - 0 | $ - 0 |
| 2024 | 3/16" Lift Cable | 200 | Linear Foot | $ - 0 | $ - 0 |
| 2025 | 3/8" Nylon Pull Rope | 200 | Linear Foot | $ - 0 | $ - 0 |
| 2026 | Replace Overhead Door Locking Devices | 10 | Each | $ - 0 | $ - 0 |
| 2027 | Molded rubber weather strip (bottom) | 150 | Linear Foot | $ - 0 | $ - 0 |
| 2028 | Angle guide weatherstrip (Vertical) | 150 | Linear Foot | $ - 0 | $ - 0 |
| 2029 | Lintel Weatherseal, 3-1/2" aluminum retainer with 3" minimum heavy brush | 150 | Linear Foot | $ - 0 | $ - 0 |
| 2030 | Wind Guides (Match existing material) | 35 | Linear Foot | $ - 0 | $ - 0 |
| 2031 | Wind locks/End locks Match existing | 50 | Each | $ - 0 | $ - 0 |
| 2032 | 2"x2"x1/8" Angle Iron | 50 | Linear Foot | $ - 0 | $ - 0 |
| 2033 | 1-1/4"x2"x1/8" Angle Iron | 50 | Linear Foot | $ - 0 | $ - 0 |
| 2034 | Anchor brackets for torsion assembly | 10 | Each | $ - 0 | $ - 0 |
| 2035 | Adjustable Track Brackerts | 10 | Each | $ - 0 | $ - 0 |
| 2036 | Pressure treated #2 or better wood door Jamb molding and trim to match the existing. Paint to match existing | 100 | Board Feet | $ - 0 | $ - 0 |
| 2037 | Metal jambs channels and/or angles to match existing | 50 | Linear Foot | $ - 0 | $ - 0 |
| 2038 | Replacement Chain for chain hoist | 50 | Linear Foot | $ - 0 | $ - 0 |
| 2039 | Door Guide wall angles roll-up doors | 20 | Linear Foot | $ - 0 | $ - 0 |
| 2040 | Replace safety edge for power operated doors. Include removal and reinstallation doors. Include removal and reinstallation of existing safety switch. | 60 | Linear Foot | $ - 0 | $ - 0 |
| 2041 | Reconfigure control panel (to require the contstant depression of the push-button in the down and or both directions. | 10 | Each | $ - 0 | $ - 0 |
| 2042 | Center Hinge | 20 | Each | $ - 0 | $ - 0 |
| 2043 | Overhead Door Top Fixture | 20 | Each | $ - 0 | $ - 0 |
| 2044 | Overhead Door Bottom Fixture | 20 | Each | $ - 0 | $ - 0 |
| 2045 | End Hinge | 20 | Each | $ - 0 | $ - 0 |
| 2046 | 2" short stem roller | 20 | Each | $ - 0 | $ - 0 |
| 2047 | 2" Long stem roller | 20 | Each | $ - 0 | $ - 0 |
| 2048 | 3" short stem roller | 10 | Each | $ - 0 | $ - 0 |
| 2049 | 3" long stem roller | 10 | Each | $ - 0 | $ - 0 |
| 2050 | Replace flange bearing on end bracket (Drive End) | 4 | Each | $ - 0 | $ - 0 |
| 2051 | Replace Flange Bearing in the Barrel Tension End | 4 | Each | $ - 0 | $ - 0 |
| Replace the following miscellaneous parts to match existing | |||||
| 2052 | Replace chain hoist mechanism complete with chain for regular door | 3 | Each | $ - 0 | $ - 0 |
| 2053 | Replace chain hoist mechanism complete with chain for fire door | 1 | Each | $ - 0 | $ - 0 |
| 2054 | Replace steel rolling curtain door hood | 60 | Linear Foot | $ - 0 | $ - 0 |
| 2055 | Replace torsion tube and spring assembly, complete | 60 | Linear Foot | $ - 0 | $ - 0 |
| 2056 | Replace Inertia Brake (below a 100 SF door) | 1 | Each | $ - 0 | $ - 0 |
| 2057 | Replace Inertia Brake (100 SF to 300 SF Door) | 1 | Each | $ - 0 | $ - 0 |
| 2058 | Replace Inertia Brake (Above a 300 SF Door) | 2 | Each | $ - 0 | $ - 0 |
| 2059 | Replace existing electric operator complete to include the following: Electric motor, transmission gear box, brake and re-connection to the existing electrical supply and pushbutton stations. | 5 | Each | $ - 0 | $ - 0 |
| 2060 | Replace Power Operator Mounting Bracket | 4 | Each | $ - 0 | $ - 0 |
| 2061 | Replace Limit Switch, to match existing, to include adjustments for proper door travel | 2 | Each | $ - 0 | $ - 0 |
| 2062 | Adjust limit switches for proper door travel | 2 | Each | $ - 0 | $ - 0 |
| 2063 | Replace electric cord from electric edge to operator switch to match existing | 50 | Linear Foot | $ - 0 | $ - 0 |
| 2064 | Reattach existing Electric Cord | 5 | Each | $ - 0 | $ - 0 |
| 2065 | Replace motor operator drive chain to match existing, to include limit switch adjustment | 5 | Each | $ - 0 | $ - 0 |
| 2066 | Replace motor drive chain sprockets to match existing. To include limit switch adjustment. | 5 | Each | $ - 0 | $ - 0 |
| 2067 | Replace curtain barrel drive chain sprockets to match existing, to include limit switch adjustment | 5 | Each | $ - 0 | $ - 0 |
| 2068 | Replace spur gear for chain hoist operation | 4 | Each | $ - 0 | $ - 0 |
| 2069 | Replace door stops to match existing | 20 | Each | $ - 0 | $ - 0 |
| 2070 | Replace push-button control station to match existing, to include wiring and reconnection to existing controls. | 2 | Each | $ - 0 | $ - 0 |
| 2071 | Replace operator control circuit board complete to match existing. Wiring to existing electric is included. | 2 | Each | $ - 0 | $ - 0 |
| 2072 | Replace headplate (below a 100 SF Door) | 1 | Each | $ - 0 | $ - 0 |
| 2073 | Replace headplate (100 SF to 300 SF Door | 2 | Each | $ - 0 | $ - 0 |
| 2074 | Replace headplate (above 300 SF Door) | 2 | Each | $ - 0 | $ - 0 |
| 2075 | Replace Barrel Shaft | 1 | Each | $ - 0 | $ - 0 |
| 2076 | Replace Barrel Shaft to include disassembly and re-assembly of door (100 SF to 300 SF door) | 2 | Each | $ - 0 | $ - 0 |
| 2077 | Replace Barrel Shaft to include disassembly and re-assembly of door (abobe a 300 SF door) | 2 | Each | $ - 0 | $ - 0 |
| 2078 | Replace final drive component "gearbox" on door operator to include coupling element or belt | 1 | Each | $ - 0 | $ - 0 |
| 2079 | Replace dual contactor in door operator of equal or better rating than the original | 2 | Each | $ - 0 | $ - 0 |
| 2080 | Reset activated or locked-up inertia brake | 1 | Each | $ - 0 | $ - 0 |
| 2081 | Replace existing sprocket with a #50-Series-84 Tooth or larger on drum or Driven Shaft | 1 | Each | $ - 0 | $ - 0 |
| 2082 | Replace existing sprocket with a #60 series-12 tooth on the Operator or Driver shaft chain | 1 | Each | $ - 0 | $ - 0 |
| 2083 | Replace existing main drive chain with a #60 series chain | 1 | Each | $ - 0 | $ - 0 |
| 2084 | Install a torque limiter on door operator | 1 | Each | $ - 0 | $ - 0 |
| Furnish and install a double accordion type gate in front of door for access control when the door is open. Shall have galvanized finish and shall have a pad-lockable tab or hasp | |||||
| 2085 | Install 6'-6" double accordion galvanize gate at 8'wide door | 1 | Each | $ - 0 | $ - 0 |
| $ - 0 |
OPTION-3
| Option 3: 2 JAN 2024 - 1 JAN 2025 | |||||
| ITEM NO | DESCRIPTION | QUANTITY | UNIT | UNIT PRICE | AMOUNT |
| 3001 | Perfrom an assessment that includes the Maintenance and minor repairs listed in Technical Exhibit 1 to determine repairs that may be required | 50 | Lump Sum | $ - 0 | $ - 0 |
| Remove existing and Install New Manually Operated Sectional Door complete to include the following cables, torsion bar,springs, drums, brackets, locks, tracks, door stops, vision glass, weather stripping and other hardware items needed for a complete and functional door unit. To include matching paint. | |||||
| 3002 | Non-Insulated - Manually Operated Sectional Door | 1,350 | Square Foot | $ - 0 | $ - 0 |
| 3003 | Insulated – Manually Operated Sectional Door | 375 | Square Foot | $ - 0 | $ - 0 |
| Remove existing and Install New Power Operated Sectional Door complete, to include the following: cables, torsion gar, springs, drums, brackets, tracks, door stops, vision glass, locks, weather stripping, gears, transmission, sprockets, door sections, electrical operator of equal or greater horsepower, electrical connection from operator, wiring to existing push button control station with "HOLD TO CLOSE" wiring option, and any functional hardware items needed for a complete door unit, to include matching paint. | |||||
| 3004 | Non-Insulated Sectional Door Complete (power-operated) | 336 | Square Foot | $ - 0 | $ - 0 |
| 3005 | Insulated Sectional Door Power Operated | 336 | Square Foot | $ - 0 | $ - 0 |
| Remove existing and Install new sectional metal overhead door parts. Paint door sections to match existing | |||||
| 3006 | Individual Door Sections(Non-Insulated) | 500 | Square Foot | $ - 0 | $ - 0 |
| 3007 | Individual Door Sections Insulated | 240 | Square Foot | $ - 0 | $ - 0 |
| 3008 | Vision Glass | 15 | Square Foot | $ - 0 | $ - 0 |
| Remove existing door and Install new chain hoist operated metal roll-up drum type, Door Complete to include the following: slats, windlocks, stops, bells-mouths, tracks, guides, bracing, gears, sprockets, chains, bearings, hoist assembly , drum covers, locking devices and other necessary hardware items for a complete functional door unit, to include matching paint | |||||
| 3009 | Non-Insulated - Chain hoist Operated Roll-Up Door | 540 | Square Foot | $ - 0 | $ - 0 |
| 3010 | Insulated - Chain Hoist Operated Roll-Up Door | 540 | Square Foot | $ - 0 | $ - 0 |
| Remove existing Door and Install New Power operated metal roll-up drum type, Door Complete to include: slats, windlocks, stops, bell0mouths, tracks, guides, bracings, gears, transmission, all sprockets, all chains, torsion tube springs, angles, weather strippings, brackets, bearings, drum, covers, lockings devices, electrical operator of equal or greater horsepower, electric connection from operator, wiring to existing push button control station with "HOLD TO CLOSE" wiring option, , replace of all necessary hardware items for a complete and functional door unit to include matching paint. | |||||
| 3011 | Non-Insulated - Power Operated Roll-Up Door | 540 | Square Foot | $ - 0 | $ - 0 |
| 3012 | Insulated Power Operated Roll-Up Door | 540 | Square Foot | $ - 0 | $ - 0 |
| 3013 | Remove existing Door and install New Chain Hoist Operated metal roll-up type UL Listed Fire Door of specified hour rating Complete to include the following: slats, windlocks, stops, bell0mouths, tracks, guides, bracings, gears, transmission, all sprockets, all chains, torsion tube springs, angles, weather strippings, brackets, bearings, drum, covers, lockings devices, electrical operator of equal or greater horsepower, electric connection from operator, wiring to existing push button control station with "HOLD TO CLOSE" wiring option, , replace of all necessary hardware items for a complete and functional door unit to include matching paint. | 300 | Square Foot | $ - 0 | $ - 0 |
| Replace the following Parts on existing roll-up drum type doors. Paint to match existing. | $ - 0 | $ - 0 | |||
| 3014 | Non-Insulated galvanized slats with continuous wind locks to match the existing | 200 | Square Foot | $ - 0 | $ - 0 |
| 3015 | Insulated galvanized steel slats with continuous wind locks to match the existing. | 200 | Square Foot | $ - 0 | $ - 0 |
| 3016 | Complete Non-Insulated Curtain Assembly with wind wind locks and end locks to match the existing | 405 | Square Foot | $ - 0 | $ - 0 |
| 3017 | Complete Insulated curtain assembly with wind locks and end locks to match the existing | 405 | Square Foot | $ - 0 | $ - 0 |
| 3018 | Door Adjustments on ALL DOORS Include the following items as applicable to the individual door. Tighten all hardware, bolts, and track brackets; straighten bent tracks, struts and door guide wall angles; lubricate all hinged hardware and rollers; adjust torsion spring tension, struts, cable drums, door and door locks. Applicable to all door types. | 20 | Each | $ - 0 | $ - 0 |
| Remove the existing and install the following new parts and/or hardware, including necessary door adjustment on all insulated and non-insulated roll-up and sectional doors as applicable, Paint to match existing | |||||
| 3019 | Add oil to gear reducer | 10 | Each | $ - 0 | $ - 0 |
| 3030 | Torsion Bar (Solid Shaft) | 40 | Linear Foot | $ - 0 | $ - 0 |
| 3021 | Torsion Bar (Hollow Shaft) | 20 | Linear Foot | $ - 0 | $ - 0 |
| 3022 | Torsion Spring | 10 | Linear Foot | $ - 0 | $ - 0 |
| 3023 | Track (Overhead Doors) 2" or 3" as required | 200 | Linear Foot | $ - 0 | $ - 0 |
| 3024 | 3/16" Lift Cable | 200 | Linear Foot | $ - 0 | $ - 0 |
| 3025 | 3/8" Nylon Pull Rope | 200 | Linear Foot | $ - 0 | $ - 0 |
| 3026 | Replace Overhead Door Locking Devices | 10 | Each | $ - 0 | $ - 0 |
| 3027 | Molded rubber weather strip (bottom) | 150 | Linear Foot | $ - 0 | $ - 0 |
| 3028 | Angle guide weatherstrip (Vertical) | 150 | Linear Foot | $ - 0 | $ - 0 |
| 3029 | Lintel Weatherseal, 3-1/2" aluminum retainer with 3" minimum heavy brush | 150 | Linear Foot | $ - 0 | $ - 0 |
| 3030 | Wind Guides (Match existing material) | 35 | Linear Foot | $ - 0 | $ - 0 |
| 3031 | Wind locks/End locks Match existing | 50 | Each | $ - 0 | $ - 0 |
| 3032 | 2"x2"x1/8" Angle Iron | 50 | Linear Foot | $ - 0 | $ - 0 |
| 3033 | 1-1/4"x2"x1/8" Angle Iron | 50 | Linear Foot | $ - 0 | $ - 0 |
| 3034 | Anchor brackets for torsion assembly | 10 | Each | $ - 0 | $ - 0 |
| 3035 | Adjustable Track Brackerts | 10 | Each | $ - 0 | $ - 0 |
| 3036 | Pressure treated #2 or better wood door Jamb molding and trim to match the existing. Paint to match existing | 100 | Board Feet | $ - 0 | $ - 0 |
| 3037 | Metal jambs channels and/or angles to match existing | 50 | Linear Foot | $ - 0 | $ - 0 |
| 3038 | Replacement Chain for chain hoist | 50 | Linear Foot | $ - 0 | $ - 0 |
| 3039 | Door Guide wall angles roll-up doors | 20 | Linear Foot | $ - 0 | $ - 0 |
| 3040 | Replace safety edge for power operated doors. Include removal and reinstallation doors. Include removal and reinstallation of existing safety switch. | 60 | Linear Foot | $ - 0 | $ - 0 |
| 3041 | Reconfigure control panel (to require the contstant depression of the push-button in the down and or both directions. | 10 | Each | $ - 0 | $ - 0 |
| 3042 | Center Hinge | 20 | Each | $ - 0 | $ - 0 |
| 3043 | Overhead Door Top Fixture | 20 | Each | $ - 0 | $ - 0 |
| 3044 | Overhead Door Bottom Fixture | 20 | Each | $ - 0 | $ - 0 |
| 3045 | End Hinge | 20 | Each | $ - 0 | $ - 0 |
| 3046 | 2" short stem roller | 20 | Each | $ - 0 | $ - 0 |
| 3047 | 2" Long stem roller | 20 | Each | $ - 0 | $ - 0 |
| 3048 | 3" short stem roller | 10 | Each | $ - 0 | $ - 0 |
| 3049 | 3" long stem roller | 10 | Each | $ - 0 | $ - 0 |
| 3050 | Replace flange bearing on end bracket (Drive End) | 4 | Each | $ - 0 | $ - 0 |
| 3051 | Replace Flange Bearing in the Barrel Tension End | 4 | Each | $ - 0 | $ - 0 |
| Replace the following miscellaneous parts to match existing | |||||
| 3052 | Replace chain hoist mechanism complete with chain for regular door | 3 | Each | $ - 0 | $ - 0 |
| 3053 | Replace chain hoist mechanism complete with chain for fire door | 1 | Each | $ - 0 | $ - 0 |
| 3054 | Replace steel rolling curtain door hood | 60 | Linear Foot | $ - 0 | $ - 0 |
| 3055 | Replace torsion tube and spring assembly, complete | 60 | Linear Foot | $ - 0 | $ - 0 |
| 3056 | Replace Inertia Brake (below a 100 SF door) | 1 | Each | $ - 0 | $ - 0 |
| 3057 | Replace Inertia Brake (100 SF to 300 SF Door) | 1 | Each | $ - 0 | $ - 0 |
| 3058 | Replace Inertia Brake (Above a 300 SF Door) | 2 | Each | $ - 0 | $ - 0 |
| 3059 | Replace existing electric operator complete to include the following: Electric motor, transmission gear box, brake and re-connection to the existing electrical supply and pushbutton stations. | 5 | Each | $ - 0 | $ - 0 |
| 3060 | Replace Power Operator Mounting Bracket | 4 | Each | $ - 0 | $ - 0 |
| 3061 | Replace Limit Switch, to match existing, to include adjustments for proper door travel | 2 | Each | $ - 0 | $ - 0 |
| 3062 | Adjust limit switches for proper door travel | 2 | Each | $ - 0 | $ - 0 |
| 3063 | Replace electric cord from electric edge to operator switch to match existing | 50 | Linear Foot | $ - 0 | $ - 0 |
| 3064 | Reattach existing Electric Cord | 5 | Each | $ - 0 | $ - 0 |
| 3065 | Replace motor operator drive chain to match existing, to include limit switch adjustment | 5 | Each | $ - 0 | $ - 0 |
| 3066 | Replace motor drive chain sprockets to match existing. To include limit switch adjustment. | 5 | Each | $ - 0 | $ - 0 |
| 3067 | Replace curtain barrel drive chain sprockets to match existing, to include limit switch adjustment | 5 | Each | $ - 0 | $ - 0 |
| 3068 | Replace spur gear for chain hoist operation | 4 | Each | $ - 0 | $ - 0 |
| 3069 | Replace door stops to match existing | 20 | Each | $ - 0 | $ - 0 |
| 3070 | Replace push-button control station to match existing, to include wiring and reconnection to existing controls. | 2 | Each | $ - 0 | $ - 0 |
| 3071 | Replace operator control circuit board complete to match existing. Wiring to existing electric is included. | 2 | Each | $ - 0 | $ - 0 |
| 3072 | Replace headplate (below a 100 SF Door) | 1 | Each | $ - 0 | $ - 0 |
| 3073 | Replace headplate (100 SF to 300 SF Door | 2 | Each | $ - 0 | $ - 0 |
| 3074 | Replace headplate (above 300 SF Door) | 2 | Each | $ - 0 | $ - 0 |
| 3075 | Replace Barrel Shaft | 1 | Each | $ - 0 | $ - 0 |
| 3076 | Replace Barrel Shaft to include disassembly and re-assembly of door (100 SF to 300 SF door) | 2 | Each | $ - 0 | $ - 0 |
| 3077 | Replace Barrel Shaft to include disassembly and re-assembly of door (abobe a 300 SF door) | 2 | Each | $ - 0 | $ - 0 |
| 3078 | Replace final drive component "gearbox" on door operator to include coupling element or belt | 1 | Each | $ - 0 | $ - 0 |
| 3079 | Replace dual contactor in door operator of equal or better rating than the original | 2 | Each | $ - 0 | $ - 0 |
| 3080 | Reset activated or locked-up inertia brake | 1 | Each | $ - 0 | $ - 0 |
| 3081 | Replace existing sprocket with a #50-Series-84 Tooth or larger on drum or Driven Shaft | 1 | Each | $ - 0 | $ - 0 |
| 3082 | Replace existing sprocket with a #60 series-12 tooth on the Operator or Driver shaft chain | 1 | Each | $ - 0 | $ - 0 |
| 3083 | Replace existing main drive chain with a #60 series chain | 1 | Each | $ - 0 | $ - 0 |
| 3084 | Install a torque limiter on door operator | 1 | Each | $ - 0 | $ - 0 |
| Furnish and install a double accordion type gate in front of door for access control when the door is open. Shall have galvanized finish and shall have a pad-lockable tab or hasp | |||||
| 3085 | Install 6'-6" double accordion galvanize gate at 8'wide door | 1 | Each | $ - 0 | $ - 0 |
| $ - 0 |
OPTION-4
| Option 4: 2 JAN 2025 - 1 JAN 2026 | |||||
| ITEM NO | DESCRIPTION | QUANTITY | UNIT | UNIT PRICE | AMOUNT |
| 4001 | Perfrom an assessment that includes the Maintenance and minor repairs listed in Technical Exhibit 1 to determine repairs that may be required | 50 | Lump Sum | $ - 0 | $ - 0 |
| Remove existing and Install New Manually Operated Sectional Door complete to include the following cables, torsion bar,springs, drums, brackets, locks, tracks, door stops, vision glass, weather stripping and other hardware items needed for a complete and functional door unit. To include matching paint. | |||||
| 4002 | Non-Insulated - Manually Operated Sectional Door | 1,350 | Square Foot | $ - 0 | $ - 0 |
| 4003 | Insulated – Manually Operated Sectional Door | 375 | Square Foot | $ - 0 | $ - 0 |
| Remove existing and Install New Power Operated Sectional Door complete, to include the following: cables, torsion gar, springs, drums, brackets, tracks, door stops, vision glass, locks, weather stripping, gears, transmission, sprockets, door sections, electrical operator of equal or greater horsepower, electrical connection from operator, wiring to existing push button control station with "HOLD TO CLOSE" wiring option, , and any functional hardware items needed for a complete door unit, to include matching paint. | |||||
| 4004 | Non-Insulated Sectional Door Complete (power-operated) | 336 | Square Foot | $ - 0 | $ - 0 |
| 4005 | Insulated Sectional Door Power Operated | 336 | Square Foot | $ - 0 | $ - 0 |
| Remove existing and Install new sectional metal overhead door parts. Paint door sections to match existing | |||||
| 4006 | Individual Door Sections(Non-Insulated) | 500 | Square Foot | $ - 0 | $ - 0 |
| 4007 | Individual Door Sections Insulated | 240 | Square Foot | $ - 0 | $ - 0 |
| 4008 | Vision Glass | 15 | Square Foot | $ - 0 | $ - 0 |
| Remove existing door and Install new chain hoist operated metal roll-up drum type, Door Complete to include the following: slats, windlocks, stops, bells-mouths, tracks, guides, bracing, gears, sprockets, chains, bearings, hoist assembly , drum covers, locking devices and other necessary hardware items for a complete functional door unit, to include matching paint | |||||
| 4009 | Non-Insulated - Chain hoist Operated Roll-Up Door | 540 | Square Foot | $ - 0 | $ - 0 |
| 4010 | Insulated - Chain Hoist Operated Roll-Up Door | 540 | Square Foot | $ - 0 | $ - 0 |
| Remove existing Door and Install New Power operated metal roll-up drum type, Door Complete to include: slats, windlocks, stops, bell0mouths, tracks, guides, bracings, gears, transmission, all sprockets, all chains, torsion tube springs, angles, weather strippings, brackets, bearings, drum, covers, lockings devices, electrical operator of equal or greater horsepower, electric connection from operator, wiring to existing push button control station with "HOLD TO CLOSE" wiring option, , replace of all necessary hardware items for a complete and functional door unit to include matching paint. | |||||
| 4011 | Non-Insulated - Power Operated Roll-Up Door | 540 | Square Foot | $ - 0 | $ - 0 |
| 4012 | Insulated Power Operated Roll-Up Door | 540 | Square Foot | $ - 0 | $ - 0 |
| 4013 | Remove existing Door and install New Chain Hoist Operated metal roll-up type UL Listed Fire Door of specified hour rating Complete to include the following: slats, windlocks, stops, bell0mouths, tracks, guides, bracings, gears, transmission, all sprockets, all chains, torsion tube springs, angles, weather strippings, brackets, bearings, drum, covers, lockings devices, electrical operator of equal or greater horsepower, electric connection from operator, wiring to existing push button control station with "HOLD TO CLOSE" wiring option, , replace of all necessary hardware items for a complete and functional door unit to include matching paint. | 300 | Square Foot | $ - 0 | $ - 0 |
| Replace the following Parts on existing roll-up drum type doors. Paint to match existing. | |||||
| 4014 | Non-Insulated galvanized slats with continuous wind locks to match the existing | 200 | Square Foot | $ - 0 | $ - 0 |
| 4015 | Insulated galvanized steel slats with continuous wind locks to match the existing. | 200 | Square Foot | $ - 0 | $ - 0 |
| 4016 | Complete Non-Insulated Curtain Assembly with wind wind locks and end locks to match the existing | 405 | Square Foot | $ - 0 | $ - 0 |
| 4017 | Complete Insulated curtain assembly with wind locks and end locks to match the existing | 405 | Square Foot | $ - 0 | $ - 0 |
| 4018 | Door Adjustments on ALL DOORS Include the following items as applicable to the individual door. Tighten all hardware, bolts, and track brackets; straighten bent tracks, struts and door guide wall angles; lubricate all hinged hardware and rollers; adjust torsion spring tension, struts, cable drums, door and door locks. Applicable to all door types. | 20 | Each | $ - 0 | $ - 0 |
| Remove the existing and install the following new parts and/or hardware, including necessary door adjustment on all insulated and non-insulated roll-up and sectional doors as applicable, Paint to match existing | |||||
| 4019 | Add oil to gear reducer | 10 | Each | $ - 0 | $ - 0 |
| 4040 | Torsion Bar (Solid Shaft) | 40 | Linear Foot | $ - 0 | $ - 0 |
| 4021 | Torsion Bar (Hollow Shaft) | 20 | Linear Foot | $ - 0 | $ - 0 |
| 4022 | Torsion Spring | 10 | Linear Foot | $ - 0 | $ - 0 |
| 4023 | Track (Overhead Doors) 2" or 3" as required | 200 | Linear Foot | $ - 0 | $ - 0 |
| 4024 | 3/16" Lift Cable | 200 | Linear Foot | $ - 0 | $ - 0 |
| 4025 | 3/8" Nylon Pull Rope | 200 | Linear Foot | $ - 0 | $ - 0 |
| 4026 | Replace Overhead Door Locking Devices | 10 | Each | $ - 0 | $ - 0 |
| 4027 | Molded rubber weather strip (bottom) | 150 | Linear Foot | $ - 0 | $ - 0 |
| 4028 | Angle guide weatherstrip (Vertical) | 150 | Linear Foot | $ - 0 | $ - 0 |
| 4029 | Lintel Weatherseal, 3-1/2" aluminum retainer with 3" minimum heavy brush | 150 | Linear Foot | $ - 0 | $ - 0 |
| 4040 | Wind Guides (Match existing material) | 35 | Linear Foot | $ - 0 | $ - 0 |
| 4031 | Wind locks/End locks Match existing | 50 | Each | $ - 0 | $ - 0 |
| 4032 | 2"x2"x1/8" Angle Iron | 50 | Linear Foot | $ - 0 | $ - 0 |
| 4033 | 1-1/4"x2"x1/8" Angle Iron | 50 | Linear Foot | $ - 0 | $ - 0 |
| 4034 | Anchor brackets for torsion assembly | 10 | Each | $ - 0 | $ - 0 |
| 4035 | Adjustable Track Brackerts | 10 | Each | $ - 0 | $ - 0 |
| 4036 | Pressure treated #2 or better wood door Jamb molding and trim to match the existing. Paint to match existing | 100 | Board Feet | $ - 0 | $ - 0 |
| 4037 | Metal jambs channels and/or angles to match existing | 50 | Linear Foot | $ - 0 | $ - 0 |
| 4038 | Replacement Chain for chain hoist | 50 | Linear Foot | $ - 0 | $ - 0 |
| 4039 | Door Guide wall angles roll-up doors | 20 | Linear Foot | $ - 0 | $ - 0 |
| 4040 | Replace safety edge for power operated doors. Include removal and reinstallation doors. Include removal and reinstallation of existing safety switch. | 60 | Linear Foot | $ - 0 | $ - 0 |
| 4041 | Reconfigure control panel (to require the contstant depression of the push-button in the down and or both directions. | 10 | Each | $ - 0 | $ - 0 |
| 4042 | Center Hinge | 20 | Each | $ - 0 | $ - 0 |
| 4043 | Overhead Door Top Fixture | 20 | Each | $ - 0 | $ - 0 |
| 4044 | Overhead Door Bottom Fixture | 20 | Each | $ - 0 | $ - 0 |
| 4045 | End Hinge | 20 | Each | $ - 0 | $ - 0 |
| 4046 | 2" short stem roller | 20 | Each | $ - 0 | $ - 0 |
| 4047 | 2" Long stem roller | 20 | Each | $ - 0 | $ - 0 |
| 4048 | 3" short stem roller | 10 | Each | $ - 0 | $ - 0 |
| 4049 | 3" long stem roller | 10 | Each | $ - 0 | $ - 0 |
| 4050 | Replace flange bearing on end bracket (Drive End) | 4 | Each | $ - 0 | $ - 0 |
| 4051 | Replace Flange Bearing in the Barrel Tension End | 4 | Each | $ - 0 | $ - 0 |
| Replace the following miscellaneous parts to match existing | |||||
| 4052 | Replace chain hoist mechanism complete with chain for regular door | 3 | Each | $ - 0 | $ - 0 |
| 4053 | Replace chain hoist mechanism complete with chain for fire door | 1 | Each | $ - 0 | $ - 0 |
| 4054 | Replace steel rolling curtain door hood | 60 | Linear Foot | $ - 0 | $ - 0 |
| 4055 | Replace torsion tube and spring assembly, complete | 60 | Linear Foot | $ - 0 | $ - 0 |
| 4056 | Replace Inertia Brake (below a 100 SF door) | 1 | Each | $ - 0 | $ - 0 |
| 4057 | Replace Inertia Brake (100 SF to 300 SF Door) | 1 | Each | $ - 0 | $ - 0 |
| 4058 | Replace Inertia Brake (Above a 300 SF Door) | 2 | Each | $ - 0 | $ - 0 |
| 4059 | Replace existing electric operator complete to include the following: Electric motor, transmission gear box, brake and re-connection to the existing electrical supply and pushbutton stations. | 5 | Each | $ - 0 | $ - 0 |
| 4060 | Replace Power Operator Mounting Bracket | 4 | Each | $ - 0 | $ - 0 |
| 4061 | Replace Limit Switch, to match existing, to include adjustments for proper door travel | 2 | Each | $ - 0 | $ - 0 |
| 4062 | Adjust limit switches for proper door travel | 2 | Each | $ - 0 | $ - 0 |
| 4063 | Replace electric cord from electric edge to operator switch to match existing | 50 | Linear Foot | $ - 0 | $ - 0 |
| 4064 | Reattach existing Electric Cord | 5 | Each | $ - 0 | $ - 0 |
| 4065 | Replace motor operator drive chain to match existing, to include limit switch adjustment | 5 | Each | $ - 0 | $ - 0 |
| 4066 | Replace motor drive chain sprockets to match existing. To include limit switch adjustment. | 5 | Each | $ - 0 | $ - 0 |
| 4067 | Replace curtain barrel drive chain sprockets to match existing, to include limit switch adjustment | 5 | Each | $ - 0 | $ - 0 |
| 4068 | Replace spur gear for chain hoist operation | 4 | Each | $ - 0 | $ - 0 |
| 4069 | Replace door stops to match existing | 20 | Each | $ - 0 | $ - 0 |
This is the start of the file's text. The full file is on GovTribe.