Attachment_1_Bid_Schedule.pdf
PDF 1 MB Posted
- Attached to
- CO-RCY MTN ARSNL-HVAC MAINT & REPAIR
- Solicitation number
- 140F0122R0124
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1 2 EA
2 10 EA
3 5 EA
1 2 EA
2 10 EA
3 5 EA
1 2 EA
Service Maintenance Calls - required within 72 hours of notification to be on site for troubleshooting.
Bi-annual (Prior to Winter and Prior to Summer) maintanance for all HVAC
Systems in Accordance withStatement of Work
BID SCHEDULE
ROCKY MOUNTAIN ARSENAL WILDLIFE REFUGE
COMMERCE CITY, CO
Project Description: Geothermal HVAC Systems and Conventional HVAC Systems Maintanance Agreement
Contractor shall furnish all labor, materials, and equipment o complete the following work in accordance with the Statement of Work
Urgent Service Maintenance Calls -required within 24 hours of notification to be on site for troubleshooting.
QTY Unit Unit Cost Total Cost
Bi-annual (Prior to Winter and Prior to Summer) maintanance for all HVAC
Systems in Accordance withStatement of Work
Option Year Two (2)
Bi-annual (Prior to Winter and Prior to Summer) maintanance for all HVAC
Systems in Accordance withStatement of
Service Maintenance Calls - required within 72 hours of notification to be on site for troubleshooting.
Base Year QTY Unit Unit Cost Total Cost
Option Year One (1) QTY Unit Unit Cost Total Cost
Urgent Service Maintenance Calls -required within 24 hours of notification to be on site for troubleshooting.
2 10 EA
3 5 EA
1 2 EA
2 10 EA
3 5 EA
1 2 EA
2 10 EA
3 5 EA
Urgent Service Maintenance Calls -required within 24 hours of notification to be on site for troubleshooting.
Service Maintenance Calls - required within 72 hours of notification to be on site for troubleshooting.
Service Maintenance Calls - required within 72 hours of notification to be on site for troubleshooting.
Service Maintenance Calls - required within 72 hours of notification to be on site for troubleshooting.
Bi-annual (Prior to Winter and Prior to Summer) maintanance for all HVAC
Systems in Accordance withStatement of Work
Option Year Three (3) QTY Unit Unit Cost Total Cost
Urgent Service Maintenance Calls -required within 24 hours of notification to be on site for troubleshooting.
Option Year Four (4) QTY Unit Unit Cost Total Cost
Bi-annual (Prior to Winter and Prior to Summer) maintanance for all HVAC
Systems in Accordance withStatement of
Urgent Service Maintenance Calls -required within 24 hours of notification to be on site for troubleshooting.
Total Price to Include All Option Years:
Location Type Manufacturer Model # SERIAL # Size
Repair/ Replacement
Cost
Copper Pipe Repair (1 ft) PVC Pipe Repair (1 ft)
UPSTAIRS MUA INNOVENT E-5000-1/WH-4205-EH/HP/FR/VS-1-E210192
COMPRESSOR 9.5 TON
SUPPLY FAN 3 HP
RETURN FAN 1.5 HP
OUTSIDE AIR DAMPER
GPS IMOD
UPSTAIRS GEOTHERMAL HEAT PUMP BOSCH ES049-4VTC
3450-008- 000001-
T111M3645
COMPRESSOR 4.0 TON
SUPPLY FAN 0.75 HP
ZONE VALVE KRUEGER 616269
GPS
NEEDLEPOIN
T GPS-FC48-AC
DISCOVERY
ROOM (IN
CEILING) GEOTHERMAL HEAT PUMP BOSCH EP070-4HZC
3450-0008- 000001- 2940517
COMPRESSOR 6 TON
SUPPLY FAN 1.0 HP
ZONE VALVE KRUEGER 616269
GPS
NEEDLEPOIN
T GPS-FC48-AC
UPSTAIRS GEOTHERMAL HEAT PUMP BOSCH EP0096-4HZC
3540-009- 000001-
T11M36509
COMPRESSOR 4 TON
COMPRESSOR 4 TON
SUPPLY FAN 2.0 HP
ZONE VALVE KRUEGER 616269
GPS
NEEDLEPOIN
T GPS-FC48-AC
UPSTAIRS GEOTHERMAL HEAT PUMP BOSCH EC096-4VTC
3540- 009000001- T11M36510
COMPRESSOR 8 TON
SUPPLY FAN 1.5 HP
ZONE VALVE KRUEGER 616269
GPS
NEEDLEPOIN
T GPS-FC48-AC
UPSTAIRS EXHAUST FAN COOK 761089
Optional Equipment Repair and Replacement Equipment List
Inlude pricing for all line items - Pricing shall include all labor, materials, and equipment to complete the repairs and replacement of the following optional equipment.
Visitor Center
BREAK ROOM GEOTHERMAL HEAT PUMP WVHF1009
AUBU1246
00093
COMPRESSOR
0.75
TON
SUPPLY FAN MCQUAY 0.1 HP
GPS
NEEDLEPOIN
T GPS-FC48-AC
OFFICE
(SARAH
METZER) GEOTHERMAL HEAT PUMP WVHF1009
AUBU1041
00423
COMPRESSOR
0.75
TON
SUPPLY FAN MCQUAY 0.1 HP
GPS
NEEDLEPOIN
T GPS-FC48-AC
OFFICE
(TERESA
CRANE) GEOTHERMAL HEAT PUMP WVHF1009
AUBU1041
00422
COMPRESSOR
0.75
TON
SUPPLY FAN MCQUAY 0.1 HP
GPS
NEEDLEPOIN
T GPS-FC48-AC
CUBICLE
AREA GEOTHERMAL HEAT PUMP WVHF1018
AUBU1041
00426
COMPRESSOR 1.5 TON
SUPPLY FAN MCQUAY 0.1 HP
GPS
NEEDLEPOIN
T GPS-FC48-AC
OFFICE
(SUSAN
DROBNIAK) GEOTHERMAL HEAT PUMP WVHF1009
AUBU1041
00421
COMPRESSOR 1.5 TON
SUPPLY FAN MCQUAY 0.1 HP
GPS
NEEDLEPOIN
T GPS-FC48-AC
VOLUNTEER
LOUNGE GEOTHERMAL HEAT PUMP WVHF1009
AUBU1041
00425
COMPRESSOR 1.5 TON
SUPPLY FAN MCQUAY 0.1 HP
GPS
NEEDLEPOIN
T GPS-FC48-AC
STAFF
HALLWAY (IN
CEILING) GEOTHERMAL HEAT PUMP BOSCH ES018-4VTC
3540-009- 000001-
T111M3613
COMPRESSOR 1.5 TON
SUPPLY FAN MCQUAY 0.75 HP
GPS
NEEDLEPOIN
T GPS-FC48-AC
STAFF
RESTROOM
(IN CEILING) GEOTHERMAL HEAT PUMP BOSCH ES024-4HZC
3540-009- 000001-
T111M3654
COMPRESSOR 2 TON
SUPPLY FAN MCQUAY 0.33 HP
COMMUNICAT
IONS GEOTHERMAL HEAT PUMP BOSCH ES024-1HZC
3540-009- 000001-
T111M3643
COMPRESSOR
0.75
TON
SUPPLY FAN MCQUAY 0.33 HP
GPS
NEEDLEPOIN
T GPS-FC48-AC
MECH ROOM PUMP ARMSTRONG 2x2x8 4380 763056 20 HP
DRIVER ABB ACH550
MECH ROOM PUMP ARMSTRONG 2x2x8 4380 763057 20 HP
DRIVER ABB ACH550
MECH ROOM GLYCOL TANK
MECH ROOM EXPANSION TANK TACO CBX254-125 Z12622
STORAGE
ROOM UNIT HEATER
TASKMASTE
R P3P5105CA1N
MECH ROOM UNIT HEATER
TASKMASTE
R P3P5105CA1N
ENTRANCE
(BY
DISCOVERY
ROOM) UNIT HEATER ELECTRIC
ENTRANCE
(BY
DISCOVERY
ROOM) UNIT HEATER ELECTRIC
STAFF
ENTRANCE UNIT HEATER ELECTRIC
LOBBY RADIANT FLOOR HEATERS ELECTRIC
PUBLIC MEN'S
RESTROOM UNIT HEATER ELECTRIC
PUBLIC
WOMEN'S
RESTROOM UNIT HEATER ELECTRIC
STAFF MEN'S
RESTROOOM UNIT HEATER ELECTRIC
STAFF
WOMEN'S
RESTROOM UNIT HEATER ELECTRIC
DISCOVERY
ROOM RADIANT FLOOR HEATERS HAUT 4250430303
Location Type Manufacturer Model # SERIAL # Size
Repair/ Replacement
Cost Copper Pipe Repair (1 ft) PVC Pipe Repair (1 ft)
MECH ROOM GEOTHERMAL PUMP
BELL &
GOSSETT
ECOCIRC XL
70-145
20180828-
01883 40 GPM
MECH ROOM GEOTHERMAL PUMP
BELL &
GOSSETT
ECOCIRC XL
70-145
20180828-
01877 40 GPM
Headquarters
LOCKER
ROOM (IN
CEILING) WATER FURNACE FAN
NBH042SL300
NBVAD2831SS
D 181100911 0.5 HP
EVAP PUMP HARTELL A3X-115
GPS
NEEDLEPOIN
T GPS-FC48-AC
MECH ROOM WATER FURNACE FAN
NBH042SL300
NBVAD2831SS
D 181100890
EVAP PUMP HARTELL A3X-115
GPS
NEEDLEPOIN
T GPS-FC48-AC
WOMEN'S
RESTROOM
(IN CEILING) WATER FURNACE FAN
NBH042SL300
NBVAD2831SS
D 181100913
EVAP PUMP HARTELL A3X-115
WORK ROOM
(IN CEILING) WATER FURNACE FAN
NBH042SL300
NBVAD2831SS
D 181100891
EVAP PUMP HARTELL A3X-115
GPS
NEEDLEPOIN
T GPS-FC48-AC
WORK ROOM
(IN CEILING) WATER FURNACE FAN
NBH042SL300
NBVAD2831SS
D 181100892 0.17 HP
EVAP PUMP HARTELL A3X-115
MEETING
CENTER WATER FURNACE FAN
NBH042SL300
NBVAD2831SS
D 181100912 1.0 HP
EVAP PUMP HARTELL A3X-115
GPS
NEEDLEPOIN
T GPS-FC48-AC
MEETING
CENTER GEOTHERMAL PUMP
BELL &
GOSSETT
ECOCIRC XL
65-130
20180911-
00552 18 GPM
MEETING
CENTER GEOTHERMAL PUMP
BELL &
GOSSETT
ECOCIRC XL
65-130
20180911-
00549 18 GPM
MEETING
CENTER MUA ALDES
GPS
NEEDLEPOIN
T GPS-FC48-AC
Location Type Manufacturer Model # SERIAL # Size
Repair/ Replacement
Cost
STAFF HALL
(IN ATTIC) FURNACE (GAS) YORK DC30-3132-24 3 TON
GPS
NEEDLEPOIN
T GPS-FC48-AC
OVER
LOCKER
ROOM FURNACE (GAS) YORK DC30-3132-24 3 TON
GPS
NEEDLEPOIN
T GPS-FC48-AC
Maintanance Building
OVER
LOCKER
ROOM FURNACE (GAS) YORK DC30-3132-24 3 TON
GPS
NEEDLEPOIN
T GPS-FC48-AC
EAST SIDE EVAPORATIVE COIL CARRIER 24ABB324A350
3021E1911
6 3.15#
CONDENSOR CARRIER
SOUTH SIDE EVAPORATIVE COIL YORK YCD48B215A
W2D18852
81 4# 8OZ
CONDENSOR YORK
SOUTH SIDE EVAPORATIVE COIL YORK YCD48B235A
W2H13933
35 3# 7OZ
CONDENSOR YORK
SOUTH SIDE EVAPORATIVE COIL YORK YCD48B235A
W2H13933
31 3# 7OZ
CONDENSOR YORK
LAB SMALL UNIT HEATER ELECTRIC
WOOD SHOP SMALL UNIT HEATER ELECTRIC
WOOD SHOP SMALL UNIT HEATER ELECTRIC
PAINT ROOM SMALL UNIT HEATER ELECTRIC
WELDING
SHOP LARGE UNIT HEATER GAS
WELDING
SHOP LARGE UNIT HEATER GAS
AUTO BAY LARGE UNIT HEATER GAS
AUTO BAY LARGE UNIT HEATER GAS
MEZZANINE SMALL UNIT HEATER ELECTRIC
MEZZANINE SMALL UNIT HEATER ELECTRIC
Location Type Manufacturer Model # SERIAL # Size
Repair/ Replacement
Cost
UPSTAIRS FURNACE (GAS) YORK DC30-3132-24 3 TON
GPS
NEEDLEPOIN
T GPS-FC48-AC
WEST SIDE EVAPORATIVE COIL YORK YCD30B225A
C2B214870
3 3# 10OZ
CONDENSOR YORK
FIRE CACHE SMALL UNIT HEATER GAS
FLUID ROOM SMALL UNIT HEATER ELECTRIC
BATTERY
ROOM SMALL UNIT HEATER ELECTRIC
TIRE ROOM SMALL UNIT HEATER ELECTRIC
PARTS ROOM SMALL UNIT HEATER ELECTRIC
MOTOR BAY LARGE UNIT HEATER GAS
MOTOR BAY LARGE UNIT HEATER GAS
MOTOR BAY LARGE UNIT HEATER GAS
MOTOR BAY LARGE UNIT HEATER GAS
MOTOR BAY LARGE UNIT HEATER GAS
MOTOR BAY LARGE UNIT HEATER GAS
WASH BAY LARGE UNIT HEATER MODINE
GAS W/
BLOWER
Fire Building
Dechlor Building
Location Type Manufacturer Model # SERIAL # Size
Repair/ Replacement
Cost
WEST SIDE SMALL UNIT HEATER ELECTRIC
EAST SIDE SMALL UNIT HEATER ELECTRIC
Location Type Manufacturer Model # SERIAL # Size
Repair/ Replacement
Cost
WEST SIDE SMALL RADIANT HEATER ELECTRIC
EAST SIDE SMALL RADIANT HEATER ELECTRIC
Location Type Manufacturer Model # SERIAL # Size
Repair/ Replacement
Cost
EAST SIDE HEAT PUMP MITSUBISHI MUZ-JP12WA 22C12878 1# 12OZ
COMMERCE CITY, CO 80022
SOUTH LADORA RESTROOM
NO ADDRESS
COMMERCE CITY, CO 80022
ROCKY MOUNTAIN ARSENAL NWR
BLACK-FOOTED FERRET OUTDOOR EXHIBIT
6550 GATEWAY ROAD
ROCKY MOUNTAIN ARSENAL NWR
| 1 |
| 2 |
File details come from the government source that posted it. Updated .