This document appears to be a detailed technical specification for an X-Ray Scanner (XIS-6545DV or similar) for government procurement. The scanner must have a tunnel size of minimum 25" x 17", overall dimensions between 80-95" long, 35-55" wide, and 50-70" high, with a dual 180kV X-ray generator offset by 90 degrees. Key technical requirements include 41mm steel penetration, conveyor height of 28-36", dual 20" LCD flat panel monitors, multi-energy 2X to 64X zoom, edge enhancement, and advanced imaging features like Picture Perfect image enhancement and auto-archiving up to 150,000 images.
Additional procurement requirements specify .5 and 1-meter entry/exit roller tables, screener assist software, Treat Image Projection (TIP), and a 12-month warranty. The equipment must be delivered, set up, and tested in Charlotte, NC, with compliance to USFDA radiation health standards. The procurement allows payment via Government Purchase Card (GPC) and requires the scanner to have features such as Z-level explosives detection, density alerts, day/date/time indicators, and the ability to print on Windows library printers. The specification supports a comprehensive and technologically advanced X-ray scanning solution for government use.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| W50S87 25 Q 5018 LRS Baggage Scanner.pdf | ||
| W50S87 25 Q 5018 LRS Baggage Scanner.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
• X-Ray Scanner - XIS-6545DV or Similar
• Tunnel Size: minimum 25” x minimum 17”
• Overall Dimensions: Minimum 80” / Maximum 95” L, Minimum 35” / Max. 55”, Min.
50/Max 70” H
• Dual 180kV X-ray generator – Offset by 90 degrees
• 41mm Typical steel penetration guaranteed
• Conveyor Height at minimum of 28” from floor; not to exceed 36”
• Superior color, with high-contrasting filters that enhances image quality for speed and accuracy
• Multi-energy, 2X to 64X zoom without pixilation
• Dual LCD Flat Panel monitors of at least 20”
• Edge enhancement, organic or inorganic imaging
• Picture Perfect image enhancement, geometrical distortion correction, auto archiving up to 150,000 imaging
• Z level detection (explosives), density alert, day/date/time indicator, baggage counter, print on any printer in windows library
• 110 VAC +/- 10% 50/60Hz, 20 Amp Max / 220VAC +/- 10% 50/60Hz, 15 Amp Max
• Compliant with 21-CFR 1020.40 (USFDA Center for Devices and Radiation Health
Standards for Cabinet X-Ray Systems
• Real Time Image Manipulation
Additional Requirements:
• .5 meter entry & exit roller table X2
• 1 meter entry & exit roller table X2
• Screener assist software for 1 machine
• Treat Image Projection (TIP)
• 12 month warranty after installation and acceptance of equipment
• Must include inside delivery, setup, and testing in Charlotte, NC to provide fully functional device
• Must accept Government Purchase Card (GPC) as payment.