This document appears to be a set of architectural drawings for the Niagara Falls Storage Site (NFSS) Waste Retrieval Facility (WRF). The drawings provide detailed plans and elevations for the proposed interim containment structure removal, including the floor plan, roof plan, elevations, building sections, and door schedule/details. Key details include the pre-engineered metal frame construction with PVC fabric covering, the north and south air locks, the equipment air locks, the fabric access portals, and the alarmed emergency egress doors. The documents also show the overall site layout and dimensions. This appears to be supporting documentation for a federal contract opportunity related to the NFSS WRF project.

View the file

Other files

File Type Posted
NFSS IWCS WRF Sources Sought Notice.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ATTACHMENT 1

Architectural Drawings

KEY PLAN

NTS

200-A-4001

A

B

C

D

E

F

G

H

J

K

L

M

N

P

Q

R

S

T

U

V

W

X

Y

Z

AA

3 4 5 6 7 8 9

12 13 14 15 16 17

200-A-4001

0'

0"

(R

EF

23' - 9" BAYS AT 20'-0" ON CENTER, TYP (SUGGESTED SPACING) 23' - 9"

BA

YS

A T

'-0

" O N

C

EN

TE

R

, T

YP

(S U

G G

ES

TE

D S

PA

C

IN

G

200-A-4003

200-A-4004

AA.1

AA.2

AA.3

AA.4

A.1

A.2

A.3

19 20

1' - 0"

33' - 1 1/2"

381' - 7 1/2" (REF)

NORTH AIR LOCK

WASTE

RETRIEVAL

SHELTER AND

CONTAINMENT

SOUTH AIR LOCK

NORTH

EQUIPMENT AIR

LOCK

SOUTH

EQUIPMENT AIR

LOCK

200-A-3001

200-A-3001

DASHED LINE INDICATES

LEAN-TO CANOPY ABOVE

LEAN-TO

33' - 1 5/8"

LE

AN

-T O

1'

5"

1"

200-A-4002

200-A-4002

10' - 0"

10' - 0"10' - 0"

9' - 6"

PROCESSING EQUIPMENT,

SEE PROCESSING DWGS

200-A-3001

200-A-3001

TYP

BURIED ABANDONED

STRUCTURES BELOW TO BE

EXCAVATED AND REMOVED

AREA LIMITED TO MASS EXCAVATION AND RAW MATERIAL

RETRIEVAL ONLY. NO ACTUAL OR PROPOSED FLOORS,

WALLS, OR INTERIOR PARTITIONS OF ANY KIND.

BURIED ABANDONED

STRUCTURES BELOW TO BE

EXCAVATED AND REMOVED

TYPICAL ALARMED EMERGENCY

EGRESS DOOR ONLY WITH PANIC

HARDWARE.

b 2102a c d e f

2102g 2102h j k m n p2102q2102r

2104b

2104a

A

3 4

A.1

A.2

A.3

1'

4"

R

EF

22' - 2" (REF)

0"

NORTH

EQUIPMENT AIR

LOCK

10' - 0" 10' - 0"

10' - 0" 10' - 0"

SLAB/FOOTING DESIGN

BY OTHERS

PRE-ENGINEERED METAL

FRAME, TYP, BY OTHERS

1' - 1"

2100b c 2100a

AA

10 11 12

AA.1

AA.2

AA.3

AA.4

20' - 0" 20' - 0"

42' - 2" (REF)

1/ 2"

(R

EF

SLAB/FOOTING DESIGN

BY OTHERS

PRE-ENGINEERED METAL

FRAME, TYP, BY OTHERS

SOUTH

EQUIPMENT AIR

LOCK

10' - 0" 10' - 0" 10' - 0" 10' - 0"

10' - 0" 10' - 0" 10' - 0" 10' - 0"

1' - 1"

2103a 2103b

2103c 2103d e

10 11

A.1

6' - 0"

3' - 0"

6'

0"

STEEL FRAMING AS

REQUIRED, BY VENDOR

2101a

2101b

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

Fi le

P at h:

Pl ot D at e:

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

BU

FF

AL

O

D

IS

TR

IC

T

N

IA

G

R A

ST

R

EE

T

BU

FF

AL

O

N Y

N

IA

G

AR

A

FA

LL

S

ST

O

R

AG

E

SI

TE

IN

TE

R

IM

C

O N

TA

IN

M

EN

T

ST

R U

C

TU

R E

R

EM

O

VA

L

JACOBS AFFIRMS THAT THE INFORMATION IN THIS DOCUMENT

HAS BEEN RIGOROUSLY REVIEWED IN ACCORDANCE WITH

THE APPROVED QUALITY CONTROL PLAN FOR THIS PROJECT.

ALL LEVELS OF SUPERVISION WITHIN EACH DISCIPLINE HAVE

PERFORMED THE APPROPRIATE REVIEWS, INTERNAL

COMMENTS HAVE BEEN RECONCILED, AND BACKCHECK

PROCESSES HAVE BEEN COMPLETED. THIS DOCUMENT IS

PREPARED FOR USACE REVIEW AND COMMENT. - TLC

C :\U se rs

\b la ck w w \D oc um en ts

\N

FS

S_

0_ W

R F-

AR

C

H _R

V2

- C

EN

TR

AL

_L ew is

.B la ck w el l.r vt 8/

/2

3:

:1

PM

0-

W

AS

TE

R

ET

R

IE

VA

L

FA

C

IL

IT

Y

(W R

F)

D .M

AR

TI

N

M .F

LE

TC

H

ER

K.

M

O O

D Y

FL

O

O R

P

LA

N

%A-3001

ST

R

U C

TU

R

AL

PLAN NORTH

SCALE: 1/32" = 1'-0"

FLOOR PLAN

NOTES:

1.

2.

3.

4.

SEE DRAWING 100-A-0001 FOR NFSS SITE PLAN.

SEE DRAWING 900-A-0001 FOR THE ARCHITECTURAL SHEET

INDEX.

SEE DRAWING 900-A-0002 FOR ABBREVIATIONS, LEGEND,

BUILDING SUMMARIES, AND GENERAL NOTES.

REFERENCE STRUCTURAL DRAWINGS FOR STRUCTURAL

GRID LINE SPACING.

A

IS

SU

ED

F O

R

0% R

EV

IE

W

/2 4/

B

IS

SU

ED

F O

R

0% R

EV

IE

W

/1 7/

PLAN NORTH

SCALE: 1/8" = 1'-0"200-A-3001

NORTH AIR LOCK2

SCALE: 1/8" = 1'-0"200-A-3001

SOUTH AIR LOCK3

0 4' 8' 16'

1/8"=1'-0SCALE:

0 16' 32' 64'

1/32"=1'-0SCALE:

1/8" = 1'-0"4 MAN DOOR AIRLOCK

DRAFT

KEY PLAN

NTS

A

B

C

D

E

F

G

H

J

K

L

M

N

P

Q

R

S

T

U

V

W

X

Y

Z

AA

3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

PVC FABRIC OVER PRE-

ENGINEERED METAL FRAME, TYP

PRE-ENGINEERED METAL FRAME

BY OTHERS

200-A-4003

200-A-4004

AA.1

AA.2

AA.3

AA.4

A.1

A.2

A.3 19 20

2" / 1'-0"

3" / 1'-0"3" / 1'-0"

3" / 1'-0" 3" / 1'-0"

PVC FABRIC OVER LEAN-TO PRE-

ENGINEERED METAL FRAME, TYP (BELOW)

PRE-ENGINEERED METAL FRAME BY OTHERS

LEAN-TO (BELOW)

PVC FABRIC OVER ACCESS PORTAL

PRE-ENGINEERED METAL FRAME, TYP

PRE-ENGINEERED METAL FRAME

BY OTHERS

PVC FABRIC OVER ACCESS PORTAL

PRE-ENGINEERED METAL FRAME, TYP

PRE-ENGINEERED METAL FRAME

BY OTHERS

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

Fi le

P at h:

Pl ot D at e:

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

BU

FF

AL

O

D

IS

TR

IC

T

N

IA

G

R A

ST

R

EE

T

BU

FF

AL

O

N Y

N

IA

G

AR

A

FA

LL

S

ST

O

R

AG

E

SI

TE

IN

TE

R

IM

C

O N

TA

IN

M

EN

T

ST

R U

C

TU

R E

R

EM

O

VA

L

JACOBS AFFIRMS THAT THE INFORMATION IN THIS DOCUMENT

HAS BEEN RIGOROUSLY REVIEWED IN ACCORDANCE WITH

THE APPROVED QUALITY CONTROL PLAN FOR THIS PROJECT.

ALL LEVELS OF SUPERVISION WITHIN EACH DISCIPLINE HAVE

PERFORMED THE APPROPRIATE REVIEWS, INTERNAL

COMMENTS HAVE BEEN RECONCILED, AND BACKCHECK

PROCESSES HAVE BEEN COMPLETED. THIS DOCUMENT IS

PREPARED FOR USACE REVIEW AND COMMENT. - TLC

C :\U se rs

\b la ck w w \D oc um en ts

\N

FS

S_

0_ W

R F-

AR

C

H _R

V2

- C

EN

TR

AL

_L ew is

.B la ck w el l.r vt 8/

/2

3:

:3

PM

0-

W

AS

TE

R

ET

R

IE

VA

L

FA

C

IL

IT

Y

(W R

F)

D .M

AR

TI

N

M .F

LE

TC

H

ER

K.

M

O O

D Y

R O

O F

PL

AN

%A-3002

ST

R

U C

TU

R

AL

A

IS

SU

ED

F O

R

0% R

EV

IE

W

/2 4/

B

IS

SU

ED

F O

R

0% R

EV

IE

W

/1 7/

1/32" = 1'-0"1 ROOF PLAN

0 16' 32' 64'

1/32"=1'-0SCALE:

NOTES:

1.

2.

3.

4.

5.

SEE DRAWING 100-A-0001 FOR NFSS SITE PLAN.

SEE DRAWING 900-A-0001 FOR THE ARCHITECTURAL SHEET

INDEX.

SEE DRAWING 900-A-0002 FOR ABBREVIATIONS, LEGEND,

BUILDING SUMMARIES, AND GENERAL NOTES.

REFERENCE STRUCTURAL DRAWINGS FOR STRUCTURAL

GRID LINE SPACING.

ANY DOORS NOT BEHIND AN AIR LOCK WILL BE

EMERGENCY EGRESS ONLY.

PLAN NORTH

ROOF FRAMING PEAK

EL 113' - 2"

2 134567891011121314151617

TO WALL

EL 41' - 6"

PVC FABRIC OVER PRE-

ENGINEERED METAL FRAME, TYP

PRE-ENGINEERED METAL FRAME

BY OTHERS

SURVEY POINT

EL 0' - 0"

7' H x 3' W PERSONNEL

DOOR, TYP, SEE PLAN

14' H x 12' W OVERHEAD

COILING DOOR

OPEN

LEAN-TO

FABRIC ACCESS PORTAL

FABRIC FACADE

33' - 1 5/8"

2" / 1'-0"

21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

TO WALL

EL 41' - 6"

SURVEY POINT

EL 0' - 0"

7' H x 3' W PERSONNEL

DOOR, TYP, SEE PLAN

14' H x 12' W OVERHEAD

COILING DOOR, TYP

CANOPY LOW EL

EL 35' - 5"

19 20

OPEN

LEAN-TO

FABRIC ACCESS PORTAL

FABRIC FACADE

33' - 1 5/8"

2" / 1'-0"

PVC FABRIC OVER PRE-

ENGINEERED METAL

FRAME, TYP

PRE-ENGINEERED METAL

FRAME BY OTHERS

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

Fi le

P at h:

Pl ot D at e:

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

BU

FF

AL

O

D

IS

TR

IC

T

N

IA

G

R A

ST

R

EE

T

BU

FF

AL

O

N Y

N

IA

G

AR

A

FA

LL

S

ST

O

R

AG

E

SI

TE

IN

TE

R

IM

C

O N

TA

IN

M

EN

T

ST

R U

C

TU

R E

R

EM

O

VA

L

JACOBS AFFIRMS THAT THE INFORMATION IN THIS DOCUMENT

HAS BEEN RIGOROUSLY REVIEWED IN ACCORDANCE WITH

THE APPROVED QUALITY CONTROL PLAN FOR THIS PROJECT.

ALL LEVELS OF SUPERVISION WITHIN EACH DISCIPLINE HAVE

PERFORMED THE APPROPRIATE REVIEWS, INTERNAL

COMMENTS HAVE BEEN RECONCILED, AND BACKCHECK

PROCESSES HAVE BEEN COMPLETED. THIS DOCUMENT IS

PREPARED FOR USACE REVIEW AND COMMENT. - TLC

C :\U se rs

\b la ck w w \D oc um en ts

\N

FS

S_

0_ W

R F-

AR

C

H _R

V2

- C

EN

TR

AL

_L ew is

.B la ck w el l.r vt 8/

/2

3:

:0

PM

0-

W

AS

TE

R

ET

R

IE

VA

L

FA

C

IL

IT

Y

(W R

F)

D .M

AR

TI

N

M .F

LE

TC

H

ER

K.

M

O O

D Y

N O

R

TH

A N

D S

O U

TH

E

LE

VA

TI

O

N S

%A-4001

ST

R

U C

TU

R

AL

SCALE: 1/32" = 1'-0"200-A-3001

NORTH ELEVATION1

SCALE: 1/32" = 1'-0"200-A-3001

SOUTH ELEVATION2

NOTES:

1.

2.

3.

SEE DRAWING 900-A-0001 FOR THE ARCHITECTURAL SHEET

INDEX.

SEE DRAWING 900-A-0002 FOR ABBREVIATIONS, LEGEND,

BUILDING SUMMARIES, AND GENERAL NOTES.

REFERENCE CIVIL DRAWINGS FOR GRADE LEVEL AND CUT

BACK.

0 16' 32' 64'

1/32"=1'-0SCALE:

A

IS

SU

ED

F O

R

0% R

EV

IE

W

/2 4/

B

IS

SU

ED

F O

R

0% R

EV

IE

W

/1 7/

TO/CONCRETE

EL 1' - 4"

ABCDEFGHJKLMNPQRSTUVWXYZAA

PVC FABRIC OVER PRE-

ENGINEERED METAL FRAME, TYP

PRE-ENGINEERED METAL FRAME

BY OTHERS

TO WALL

EL 41' - 6"

T/MAN DOOR

EL 11' - 4 1/2"

TO/EQUIPMENT AIRLOCK

EL 21' - 4"

7' H x 3' W PERSONNEL

DOOR, TYP, SEE PLAN

CANOPY LOW EL

EL 35' - 5"

AA.1AA.2AA.3AA.4 A.1 A.2 A.3

LEAN-TO

FABRIC ACCESS

PORTAL (BEYOND)

FABRIC ACCESS

PORTAL (BEYOND)

MECHANICAL EQUIPMENT, TYP

SEE MECHANICAL DWGS

ROOF FRAMING PEAK

EL 113' - 2"

TO/CONCRETE

EL 1' - 4"

A B C D E F G H J K L M N P Q R S T U V W X Y Z AA

PVC FABRIC OVER PRE-

ENGINEERED METAL FRAME, TYP

PRE-ENGINEERED METAL FRAME

BY OTHERS

TO WALL

EL 41' - 6"

SURVEY POINT

EL 0' - 0"7' H x 3' W PERSONNEL

DOOR, TYP, SEE PLAN

AA.1 AA.2 AA.3 AA.4A.1A.2A.3

FABRIC ACCESS

PORTAL (BEYOND)

FABRIC ACCESS PORTAL (BEYOND)

MECHANICAL EQUIPMENT, TYP

SEE MECHANICAL DWGS

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

Fi le

P at h:

Pl ot D at e:

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

BU

FF

AL

O

D

IS

TR

IC

T

N

IA

G

R A

ST

R

EE

T

BU

FF

AL

O

N Y

N

IA

G

AR

A

FA

LL

S

ST

O

R

AG

E

SI

TE

IN

TE

R

IM

C

O N

TA

IN

M

EN

T

ST

R U

C

TU

R E

R

EM

O

VA

L

JACOBS AFFIRMS THAT THE INFORMATION IN THIS DOCUMENT

HAS BEEN RIGOROUSLY REVIEWED IN ACCORDANCE WITH

THE APPROVED QUALITY CONTROL PLAN FOR THIS PROJECT.

ALL LEVELS OF SUPERVISION WITHIN EACH DISCIPLINE HAVE

PERFORMED THE APPROPRIATE REVIEWS, INTERNAL

COMMENTS HAVE BEEN RECONCILED, AND BACKCHECK

PROCESSES HAVE BEEN COMPLETED. THIS DOCUMENT IS

PREPARED FOR USACE REVIEW AND COMMENT. - TLC

C :\U se rs

\b la ck w w \D oc um en ts

\N

FS

S_

0_ W

R F-

AR

C

H _R

V2

- C

EN

TR

AL

_L ew is

.B la ck w el l.r vt 8/

/2

3:

:2

PM

0-

W

AS

TE

R

ET

R

IE

VA

L

FA

C

IL

IT

Y

(W R

F)

D .M

AR

TI

N

M .F

LE

TC

H

ER

K.

M

O O

D Y

EA

ST

A N

D W

ES

T

EL

EV

AT

IO

N S

%A-4002

ST

R

U C

TU

R

AL

SCALE: 1/32" = 1'-0"200-A-3001

EAST ELEVATION1

SCALE: 1/32" = 1'-0"200-A-3001

WEST ELEVATION2

NOTES:

1.

2.

3.

SEE DRAWING 900-A-0001 FOR THE ARCHITECTURAL SHEET

INDEX.

SEE DRAWING 900-A-0002 FOR ABBREVIATIONS, LEGEND,

BUILDING SUMMARIES, AND GENERAL NOTES.

REFERENCE CIVIL DRAWINGS FOR GRADE LEVEL AND CUT

BACK.

0 16' 32' 64'

1/32"=1'-0SCALE:

A

IS

SU

ED

F O

R

0% R

EV

IE

W

/2 4/

B

IS

SU

ED

F O

R

0% R

EV

IE

W

/1 7/

TO/CONCRETE

EL 1' - 4"

21 7 8 9 10 11 12 17

TO WALL

EL 41' - 6"

SURVEY POINT

EL 0' - 0"

CANOPY LOW EL

EL 35' - 5"

200-A-4004

PVC FABRIC OVER PRE-

ENGINEERED METAL FRAME, TYP

PRE-ENGINEERED METAL FRAME

BY OTHERS

PVC FABRIC OVER

LEAN-TO PRE-

ENGINEERED METAL

FRAME, BY OTHERS

FOUNDATION AND SUPPORT

CONFIGURATION BY OTHERS

SEE S-3001 FOR FOUNDATION

AND BEARING LAYOUT

PVC FABRIC OVER PRE-

ENGINEERED METAL FRAME, TYP

PRE-ENGINEERED METAL FRAME

BY OTHERS

PVC FABRIC OVER PRE-

ENGINEERED METAL FRAME, TYP

METAL FRAME BY OTHERS

19 20

2" / 1'-0"

OPEN

EARTH TO BE REMOVED

FOR TREATMENT

WASTE

RETRIEVAL

SHELTER AND

CONTAINMENT

WASTE

RETRIEVAL

SHELTER AND

CONTAINMENT

WASTE

RETRIEVAL

SHELTER AND

CONTAINMENT

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

Fi le

P at h:

Pl ot D at e:

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

BU

FF

AL

O

D

IS

TR

IC

T

N

IA

G

R A

ST

R

EE

T

BU

FF

AL

O

N Y

N

IA

G

AR

A

FA

LL

S

ST

O

R

AG

E

SI

TE

IN

TE

R

IM

C

O N

TA

IN

M

EN

T

ST

R U

C

TU

R E

R

EM

O

VA

L

JACOBS AFFIRMS THAT THE INFORMATION IN THIS DOCUMENT

HAS BEEN RIGOROUSLY REVIEWED IN ACCORDANCE WITH

THE APPROVED QUALITY CONTROL PLAN FOR THIS PROJECT.

ALL LEVELS OF SUPERVISION WITHIN EACH DISCIPLINE HAVE

PERFORMED THE APPROPRIATE REVIEWS, INTERNAL

COMMENTS HAVE BEEN RECONCILED, AND BACKCHECK

PROCESSES HAVE BEEN COMPLETED. THIS DOCUMENT IS

PREPARED FOR USACE REVIEW AND COMMENT. - TLC

C :\U se rs

\b la ck w w \D oc um en ts

\N

FS

S_

0_ W

R F-

AR

C

H _R

V2

- C

EN

TR

AL

_L ew is

.B la ck w el l.r vt 8/

/2

3:

:5

PM

0-

W

AS

TE

R

ET

R

IE

VA

L

FA

C

IL

IT

Y

(W R

F)

D .M

AR

TI

N

M .F

LE

TC

H

ER

Su bm itt er

K.

M

O O

D Y

BU

IL

D

IN

G S

EC

TI

O N

S

%A-4003

ST

R

U C

TU

R

AL

NOTES:

1.

2.

SEE DRAWING 900-A-0001 FOR THE ARCHITECTURAL SHEET

INDEX.

SEE DRAWING 900-A-0002 FOR ABBREVIATIONS, LEGEND,

BUILDING SUMMARIES, AND GENERAL NOTES.

A

IS

SU

ED

F O

R

0% R

EV

IE

W

/1 7/

SCALE: 3/32" = 1'-0"200-A-3001

BUILDING SECTION1

0 8' 16' 24'

SCALE: 3/32" = 1'-0"

TO/CONCRETE

EL 1' - 4"

ABCDXYZAA

TO WALL

EL 41' - 6"

SURVEY POINT

EL 0' - 0"

TO/EQUIPMENT AIRLOCK

EL 21' - 4"

200-A-4003

PVC FABRIC OVER PRE-

ENGINEERED METAL FRAME, TYP

PRE-ENGINEERED METAL FRAME

BY OTHERS

EMERGENCY EGRESS

ONLY PERSONNEL

DOOR, TYP

PVC FABRIC OVER PRE-

ENGINEERED METAL FRAME, TYP

PRE-ENGINEERED METAL FRAME

BY OTHERS

AA.1AA.2AA.3AA.4 A.1 A.2 A.3

PVC FABRIC OVER PRE-ENGINEERED METAL

FRAME, TYP

PRE-ENGINEERED METAL FRAME BY OTHERS

14' H x 12' W OVERHEAD

COILING DOOR, TYP

FABRIC ACCESS

PORTAL (BEYOND)

EARTH TO BE REMOVED

FOR TREATMENT

FOUNDATION AND SUPPORT

CONFIGURATION BY OTHERS

SEE S-3001 FOR FOUNDATION

AND BEARING LAYOUT

FOUNDATION AND SUPPORT

CONFIGURATION BY OTHERS

SEE S-3001 FOR FOUNDATION

AND BEARING LAYOUT

SOUTH

EQUIPMENT AIR

LOCK

WASTE

RETRIEVAL

SHELTER AND

CONTAINMENT

WASTE

RETRIEVAL

SHELTER AND

CONTAINMENT

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

Fi le

P at h:

Pl ot D at e:

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

BU

FF

AL

O

D

IS

TR

IC

T

N

IA

G

R A

ST

R

EE

T

BU

FF

AL

O

N Y

N

IA

G

AR

A

FA

LL

S

ST

O

R

AG

E

SI

TE

IN

TE

R

IM

C

O N

TA

IN

M

EN

T

ST

R U

C

TU

R E

R

EM

O

VA

L

JACOBS AFFIRMS THAT THE INFORMATION IN THIS DOCUMENT

HAS BEEN RIGOROUSLY REVIEWED IN ACCORDANCE WITH

THE APPROVED QUALITY CONTROL PLAN FOR THIS PROJECT.

ALL LEVELS OF SUPERVISION WITHIN EACH DISCIPLINE HAVE

PERFORMED THE APPROPRIATE REVIEWS, INTERNAL

COMMENTS HAVE BEEN RECONCILED, AND BACKCHECK

PROCESSES HAVE BEEN COMPLETED. THIS DOCUMENT IS

PREPARED FOR USACE REVIEW AND COMMENT. - TLC

C :\U se rs

\b la ck w w \D oc um en ts

\N

FS

S_

0_ W

R F-

AR

C

H _R

V2

- C

EN

TR

AL

_L ew is

.B la ck w el l.r vt 8/

/2

3:

:1

PM

0-

W

AS

TE

R

ET

R

IE

VA

L

FA

C

IL

IT

Y

(W R

F)

D .M

AR

TI

N

M .F

LE

TC

H

ER

Su bm itt er

K.

M

O O

D Y

BU

IL

D

IN

G S

EC

TI

O N

S

%A-4004

ST

R

U C

TU

R

AL

NOTES:

1.

2.

SEE DRAWING 900-A-0001 FOR THE ARCHITECTURAL SHEET

INDEX.

SEE DRAWING 900-A-0002 FOR ABBREVIATIONS, LEGEND,

BUILDING SUMMARIES, AND GENERAL NOTES.

A

IS

SU

ED

F O

R

0% R

EV

IE

W

/1 7/

SCALE: 3/32" = 1'-0"200-A-3001

BUILDING SECTION1

0 8' 16' 24'

SCALE: 3/32" = 1'-0"

A B

OVERHEAD COILING DOOR

12' - 0"

7'-0" H x 3'-0" W OPENING

HOLLOW METAL FRAME

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

Fi le

P at h:

Pl ot D at e:

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

BU

FF

AL

O

D

IS

TR

IC

T

N

IA

G

R A

ST

R

EE

T

BU

FF

AL

O

N Y

N

IA

G

AR

A

FA

LL

S

ST

O

R

AG

E

SI

TE

IN

TE

R

IM

C

O N

TA

IN

M

EN

T

ST

R U

C

TU

R E

R

EM

O

VA

L

JACOBS AFFIRMS THAT THE INFORMATION IN THIS DOCUMENT

HAS BEEN RIGOROUSLY REVIEWED IN ACCORDANCE WITH

THE APPROVED QUALITY CONTROL PLAN FOR THIS PROJECT.

ALL LEVELS OF SUPERVISION WITHIN EACH DISCIPLINE HAVE

PERFORMED THE APPROPRIATE REVIEWS, INTERNAL

COMMENTS HAVE BEEN RECONCILED, AND BACKCHECK

PROCESSES HAVE BEEN COMPLETED. THIS DOCUMENT IS

PREPARED FOR USACE REVIEW AND COMMENT. - TLC

C :\U se rs

\b la ck w w \D oc um en ts

\N

FS

S_

0_ W

R F-

AR

C

H _R

V2

- C

EN

TR

AL

_L ew is

.B la ck w el l.r vt 8/

/2

3:

:3

PM

0-

W

AS

TE

R

ET

R

IE

VA

L

FA

C

IL

IT

Y

(W R

F)

D .M

AR

TI

N

M .F

LE

TC

H

ER

Su bm itt er

K.

M

O O

D Y

D O

O R

S C

H

ED

U

LE

A N

D D

ET

AI

LS

%A-5001

ST

R

U C

TU

R

AL

NOTES:

1.

2.

SEE DRAWING 900-A-0001 FOR THE ARCHITECTURAL SHEET

INDEX.

SEE DRAWING 900-A-0002 FOR ABBREVIATIONS, LEGEND,

BUILDING SUMMARIES, AND GENERAL NOTES.

0 2' 4' 8'

SCALE: 1/4" = 1'-0"

A

IS

SU

ED

F O

R

0% R

EV

IE

W

/1 7/

DOOR SCHEDULE

DOOR NO. TYPE

DOOR

FIRE RATING

FRAME

Sill HARDWARE COMMENTS:

SIZE

FINISH UNDER CUT TYPE MATERIAL

DETAILS

WIDTH HEIGHT THICKNESS HEAD JAMB

2102r A 3' - 0" 7' - 0" 0' - 1 3/4" TBD TBD TBD TBD TBD TBD TBD TBD PANIC AND ALARMED EMERGENCY EGRESS ONLY 2101a A 3' - 0" 7' - 0" 0' - 1 3/4" TBD TBD TBD TBD TBD TBD TBD TBD TBD AIR LOCK 2102h A 3' - 0" 7' - 0" 0' - 1 3/4" TBD TBD TBD TBD TBD TBD TBD TBD PANIC AND ALARMED EMERGENCY EGRESS ONLY 2104a A 3' - 0" 7' - 0" 0' - 1 3/4" TBD TBD TBD TBD TBD TBD TBD TBD TBD AIR LOCK 2100b B 12' - 0" 14' - 0" 0' - 3" TBD TBD TBD TBD TBD TBD TBD TBD TBD AIR LOCK 2100a B 12' - 0" 14' - 0" 0' - 3" TBD TBD TBD TBD TBD TBD TBD TBD TBD AIR LOCK 2103a B 12' - 0" 14' - 0" 0' - 3" TBD TBD TBD TBD TBD TBD TBD TBD TBD AIR LOCK 2103c B 12' - 0" 14' - 0" 0' - 3" TBD TBD TBD TBD TBD TBD TBD TBD TBD AIR LOCK 2102c A 3' - 0" 7' - 0" 0' - 1 3/4" TBD TBD TBD TBD TBD TBD TBD TBD PANIC AND ALARMED AIR LOCK 2102b A 3' - 0" 7' - 0" 0' - 1 3/4" TBD TBD TBD TBD TBD TBD TBD TBD PANIC AND ALARMED EMERGENCY EGRESS ONLY 2102d A 3' - 0" 7' - 0" 0' - 1 3/4" TBD TBD TBD TBD TBD TBD TBD TBD PANIC AND ALARMED EMERGENCY EGRESS ONLY 2102e A 3' - 0" 7' - 0" 0' - 1 3/4" TBD TBD TBD TBD TBD TBD TBD TBD PANIC AND ALARMED EMERGENCY EGRESS ONLY 2102f A 3' - 0" 7' - 0" 0' - 1 3/4" TBD TBD TBD TBD TBD TBD TBD TBD PANIC AND ALARMED EMERGENCY EGRESS ONLY 2102j A 3' - 0" 7' - 0" 0' - 1 3/4" TBD TBD TBD TBD TBD TBD TBD TBD PANIC AND ALARMED EMERGENCY EGRESS ONLY 2102k A 3' - 0" 7' - 0" 0' - 1 3/4" TBD TBD TBD TBD TBD TBD TBD TBD PANIC AND ALARMED EMERGENCY EGRESS ONLY 2102m A 3' - 0" 7' - 0" 0' - 1 3/4" TBD TBD TBD TBD TBD TBD TBD TBD PANIC AND ALARMED EMERGENCY EGRESS ONLY 2102n A 3' - 0" 7' - 0" 0' - 1 3/4" TBD TBD TBD TBD TBD TBD TBD TBD PANIC AND ALARMED EMERGENCY EGRESS ONLY 2102p A 3' - 0" 7' - 0" 0' - 1 3/4" TBD TBD TBD TBD TBD TBD TBD TBD PANIC AND ALARMED EMERGENCY EGRESS ONLY 2104b A 3' - 0" 7' - 0" 0' - 1 3/4" TBD TBD TBD TBD TBD TBD TBD TBD TBD AIR LOCK 2102g A 3' - 0" 7' - 0" 0' - 1 3/4" TBD TBD TBD TBD TBD TBD TBD TBD PANIC AND ALARMED EMERGENCY EGRESS ONLY 2102a A 3' - 0" 7' - 0" 0' - 1 3/4" TBD TBD TBD TBD TBD TBD TBD TBD PANIC AND ALARMED EMERGENCY EGRESS ONLY 2102q A 3' - 0" 7' - 0" 0' - 1 3/4" TBD TBD TBD TBD TBD TBD TBD TBD PANIC AND ALARMED EMERGENCY EGRESS ONLY 2101b A 3' - 0" 7' - 0" 0' - 1 3/4" TBD TBD TBD TBD TBD TBD TBD TBD TBD AIR LOCK 2103b B 12' - 0" 14' - 0" 0' - 3" TBD TBD TBD TBD TBD TBD TBD TBD TBD AIR LOCK 2103d B 12' - 0" 14' - 0" 0' - 3" TBD TBD TBD TBD TBD TBD TBD TBD TBD AIR LOCK 2100c A 3' - 0" 7' - 0" 0' - 1 3/4" TBD TBD TBD TBD TBD TBD TBD TBD PANIC AND ALARMED EMERGENCY EGRESS ONLY 2103e A 3' - 0" 7' - 0" 0' - 1 3/4" TBD TBD TBD TBD TBD TBD TBD TBD PANIC AND ALARMED EMERGENCY EGRESS ONLY

SCALE: 1/4" = 1'-0"

DOOR DETAILS

200-A-0001 - LIFE SAFETY - GENERAL INFORMATION
200-A-0002 - LIFE SAFETY PLAN
200-A-3001 - FLOOR PLAN
200-A-3002 - ROOF PLAN
200-A-4001 - NORTH AND SOUTH ELEVATIONS
200-A-4002 - EAST AND WEST ELEVATIONS
200-A-4003 - BUILDING SECTIONS
200-A-4004 - BUILDING SECTIONS
200-A-5001 - DOOR SCHEDULE AND DETAILS
Blank Page