ALC DRAFT
DATE ISSUED:
WORKORDER #:
REQUESTOR:
02/19/20
PT30-6597
U SWANN
ISSUED BY: IOD SHOP 103
DRAFT DRAWING PRODUCED BY ALC
12.750
.407 .296 1.282
1.187
6.250
11.000
2.657 2.546
SOURCE CONTROL
ITEM PART NO. NOMENCLATURE MATERIAL QTY
- 405-525-17 LIQUID CONTAINER, C-130J MIL-J-25718 1
NEXT ASSY USED ON
APPLICATION
REV
STATUS
REV SH
SHREV
APPROVED:
DRAWN BY: J HERMAN
CHECKED BY:
ESD QC:
IOD/AA QC:
ORIGINATOR: U SWANN
DATE:
SIZE
ZONE
LIQUID CONTAINER, C-130J
HC-130J
BY CHECK
REVISIONS
APPRDATEDESCRIPTIONREV
D
C
A
C
D
A
B
.XXX
ANGLEDECIMAL
TOLERANCES ON:
DIMENSIONS ARE IN INCHES.
UNLESS OTHERWISE SPECIFIED
PARTS LIST
D
SCALE: 1:2 SHEET 1 OF
REVDRAWING NO.CAGE CODE
ELIZABETH CITY, NC 27909
AVIATION LOGISTICS CENTER
U. S. COAST GUARD
27426 -
.X .XX
405-525-17
12345678
.010 1/2 .03 .1
WARNING- This document contains technical data whose export is restricted by the Arms Export-Control Act (Title 22, U.S.C., Sec 2751, et. seq.) or the Export Administration Act of 1979, as amended, Title 50, U.S.C. App 2401 et. seq.
Violations of these export laws are subject to severe criminal penalties.
Disseminate in accordance with provisions of DoD Directive 5230.25.
Distribution authorized to the DHS/CG/DoD and their contractors, for administrative or operational purposes only, determined on Approval Date in title block. Other requests shall be referred to U. S. Coast Guard Aviation Logistics Center, ESD Technical Publications Department, Elizabeth City, NC 27909.
DISTRIBUTION STATEMENT D
B
NOTES:
BREAK AND DEBURR ALL SHARP EDGES.1.
MARK WITH PART NUMBER AND CAGE CODE IAW MIL-STD-130.2.
FINISH: NONE.3.
REFERENCE PART NUMBER(S):4.
OEM 695856
DESTRUCTION NOTICE- For unclassified, limited documents, destroy by any method that will prevent disclosure of contents or reconstruction of the document. 1
DESIGN REQUIREMENTS:
THE LIQUID CONTAINER SHALL CONFORM TO THE REQUIREMENTS OF THIS DRAWING AND OF SPECIFICATION MIL-J-257181.
(USAF). IN THE EVENT OF ANY CONFLICT, THIS DRAWING SHALL GOVERN.
IN ADDITION THE REQUIREMENTS OF SPECIFICATION MIL-J-25718 (USAF), THE LIQUID CONTAINER SHALL INCORPORATE A DRY2.
ICE WELL OR CONTAINER.
THE DRY ICE WELL SHALL EXTEND DOWN INTO THE LIQUID CONTAINER AND SHALL BE PERMANENTLY ATTACHED TO THE1.
LIQUID CONTAINER LID.
THE DRY ICE WELL SHALL HAVE A MINIMUM INTERNAL VOLUME OF 33 CUBIC INCHES.2.
THE DRY ICE WELL SHALL BE CAPABLE OF BEING FILLED THROUGH A CAP THREADED INTO THE LIQUID CONTAINER LID.3.
THE DRY ICE WELL THREADED FILLER CAP SHALL BE VENTED TO ATMOSPHERE TO RELIEVE GAS PRESSURE WITHIN THE WELL4.
RESULTING FROM THE SUBLIMATION OF DRY ICE.
THE DRY ICE WELL MATERIAL SHALL CONFORM TO THE REQUIREMENTS OF SPECIFICATION MIL-J-25718 (USAF).5.
THE LIQUID CONTAINER SHALL HAVE THE FOLLOWING COLD TEMPERATURE CAPABILITY:3.
WITH ITS ICE WELL FILLED WITH CRACKED OR SOLID DRY ICE AND ITS INTERIOR FILLED WITH TWO GALLONS OF WATER THE1.
INITIAL TEMPERATURE OF WHICH IS +70 F. THE LIQUID CONTAINER SHALL KEEP THE LIQUID TEMPERATURE WITHIN THE RANGE
OF +55 F 10 F.
THE LIQUID CONTAINER SHALL MAINTAIN THE ABOVE TEMPERATRUE RANGE FOR SIX (6) HOURS WHEN EXPOSED TO AN2.
AMBIENT TEMPERATURE OF +100 F.
QUALIFICATION APPROVAL:
QUALIFICATION TESTS: IN ADDITION TO TESTS REQUIRED BY PARAGRAPH 4.3 OF SPECIFICATION MIL-J-25718 (USAF), THE LIQUID
CONTAINER SHALL SUCCESSFULLY WITHSTAND THE FOLLOWING TEST:
1. THE LIQUID CONTAINER ICE WELL SHALL BE FILLED TO CAPACITY WITH CRACKED DRY ICE. THE INITIAL INTERNAL TEMPERATURE OF THE LIQUID CONTAINER SHALL BE +80 F 2 F. THE LIQUID CONTAINER SHALL BE FILLED WITH TWO GALLONS
OF WATER THE INITIAL TEMPERATURE OF WHICH SHALL BE +70 F.
2. THE LIQUID CONTAINER, THUS FILLED, SHALL BE PLACED IN A TEST CHAMBER THE INTIAL TEMPERATURE OF WHICH SHALL HAVE BEEN STABILIZED AT +100 F 2 F. THE LIQUID CONTAINER SHALL REMAIN IN THE TEST CHAMBER FOR SIX (6) HOURS.
3. AT THE END OF THE SIX (6) HOUR PERIOD THE WATER TEMPERATURE SHALL BE WITHIN THE RANGE OF +55 F 10 F AND NO
DAMAGE SHALL HAVE OCCURRED TO THE CONTAINER AS A RESULT OF THE HEAT.
TEST REPORTS: AS PROOF OF COMPLIANCE TO THE REQUIREMENTS OF THIS DRAWING, EIGHT (8) COPIES OF A TEST REPORT PREPARED IN ACCORDANCE WITH SPECIFICATION MIL-T-9107, OMITTING PARAGRAPH 3.2.2, SHALL BE SUBMITTED TO THE LOCKHEED AIRCRAFT CORPORATION, MARIETTA, FEORGIA, PIROR TO DELIVERY OF THE FIRST PRODUCTION ARTICLE.
FUNCTIONAL TEST: NONE
IDENTIFICATION MARKING: EACH LIQUID CONTAINER SHALL BE MARKED IN ACCORDANCE WITH SPECIFICATION MIL-STD-130. THE FOLLOWING MINIMUM INFORMATION SHALL BE INCLUDED FOR LOCKHEED INDENTIFICATION AND INSPECTION:
MANUFACTURER'S NAME OR TRADEMARK1.
MANUFACTURER'S PART NUMBER2.
IN ADDITION, THE LOCKHEED PART NUMBER SHALL BE RUBBER STAMPED ON EACH LIQUID CONTAINER IN SUCH A MANNER THAT IT WILL NOT BE CONFUSED WITH THE INFORMATION CALLED FOR BY SPECIFICATION MIL-STD-130.
PACKAGING: EACH LIQUID CONTAINER SHALL BE PACKAGED IN SUCH A MANNER THAT IT WILL NOT BE DAMAGED UNDER NORMAL HANDLING OR STORAGE CONDITIONS. ALL CONTAINERS AND INDIVIDUAL PACKAGES SHALL BE MARKED TO SHOW THE SAME INFORMATION REQUIRED UNDER "IDENTIFICATION MARKING" AND LABELLED "HANDLE WITH CARE".