This document provides details for a federal contract opportunity to upgrade the Leadville Water Treatment Plant. The solicitation number is 140R6024R0009 and is being issued by the Department of the Interior Bureau of Reclamation for pre-solicitation purposes. The opportunity involves upgrading infrastructure at the Leadville Water Treatment Plant to improve water treatment services. Interested parties are invited to review additional specifications in Attachment_08_00_00_01_Specifications_8of9_LeadvilleWTP-B3_11-07-2023_1.pdf to understand the full scope of work. Upgrades are expected to include improvements to water intake, filtration, disinfection and other core treatment processes. The solicitation number and agency points of contact should be referenced when inquiring about response due dates and other procurement details.
View the file
Other files
Show all 20
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Rockwell Automation Publication 100-TD013I-EN-P - February 2021 5
100-K/104-K Miniature Contactors
Product Selection
• 3-Pole AC- and DC-operated contactors
• Compact size
• Same dimensions for AC and DC
• Full-voltage non-reversing and reversing contactors
• 5, 9, and 12 A contactors rated at 690V
• IP2X finger protection
• Optional integrated surge suppressor
• Compatible with Bulletin 193-K bimetallic overload relay
• Mirror contacts per IEC 60947-4-1 and mechanically linked contacts per IEC 60947-5-1 on main unit
Bulletin 100-K miniature contactors are designed for commercial and light industrial applications where panel space is at a premium. These miniature devices, while 45 mm wide, are shallower and have less panel depth requirements than standard IEC contactors.
The miniature contactors have been designed with flexibility in mind. They are available with AC or DC operating coils, several contact ratings, and optional 2- or 4-pole adder decks in a variety of auxiliary contact configurations.
Ä Coil voltage code — see page 6.
3-Pole AC- and DC-operated Contactors
Rated Operational Current Ie [A]
Ratings for switching AC motors - AC-2, AC-3, AC-4 Auxiliary Contacts
Pkg.
Qty.(1)
(1) May be ordered in package quantities of 20. Add letter M to the end of the cat. no. Example: 100-K09ZJ10M.
Cat. No.3-phase kW (50 Hz) Hp (60 Hz)
40 °C (104 °F) 230V 400/415V 500V 690V
1-Phase 3-Phase
AC-3 AC-1 115V 230V 200V 230V 460V 575V N.O. N.C.
Screw Terminals
5 20 1.5 2.2 2.2 2.2 1/2 1 1-1/2 1-1/2 3 3 1 0 1 100-K05Ä10
0 1 1 100-K05Ä01
9 20 3 4 4 4 1/2 1-1/2 2 2 5 5 1 0 1 100-K09Ä10
0 1 1 100-K09Ä01
12 20 3 5.5 5.5 5.5 3/4 2 3 3 7-1/2 7-1/2 1 0 1 100-K12Ä10
0 1 1 100-K12Ä01
Spring Clamp Terminals
5 10 1.5 2.2 2.2 2.2 1/3 3/4 1-1/2 1-1/2 3 3
1 0 1 100-KR05Ä10
0 1 1 100-KR05Ä01
9 10 2.2 4 4 4 1/3 1 2 2 5 5
1 0 1 100-KR09Ä10
0 1 1 100-KR09Ä01
100-K Miniature
Contactor
104-K Reversing Miniature Contactor jpeterson Rectangle 100-K Miniature Contactor jpeterson Line jpeterson Line jpeterson Line jpeterson Line jpeterson Text Box
ALLEN-BRADLEY 100-K09ZJ400
6 Rockwell Automation Publication 100-TD013I-EN-P - February 2021
100-K/104-K Miniature Contactors Product Selection
Coil Voltage Codes
The Cat. No. as listed is incomplete. Select a coil voltage code from the table below to complete the Cat. No.
Example: 120V, 60 Hz: Cat. No. 100-K09Ä10 becomes Cat. No.100-K09D10.
4-Pole AC- and DC-operated Contactors
Rated Operational Current Ie [A]
Ratings for switching AC motors - AC-2, AC-3 Contact Configuration, Main Poles
Pkg. Qty.(1)
(1) May be ordered in package quantities of 20. Add letter M to the end of the cat. no. Example: 100-K09ZJ400M.
Cat. No.3-phase kW (50 Hz) Hp (60 Hz)
40 °C (104 °F) 230V
400/ 415V 500V 690V
1-Phase 3-Phase
AC-3 AC-1 115V 230V 200V 230V 460V 575V N.O. N.C.
5 20 1.5 2.2 2.2 2.2 1/2 1 1-1/2 1-1/2 3 3
4 0 1 100-K05Ä400
3 1 1 100-K05Ä300
2 2 1 100-K05Ä200
9 20 3 4 4 4 1/2 1-1/2 2 2 5 5
4 0 1 100-K09Ä400
3 1 1 100-K09Ä300
2 2 1 100-K09Ä200
12 20 3 5.5 5.5 5.5 3/4 2 3 3 7-1/2 7-1/2
4 0 1 100-K12Ä400
3 1 1 100-K12Ä300
2 2 1 100-K12Ä200
Reversing AC- and DC-operated Contactors
Rated Operational Current Ie [A]
Ratings for switching AC motors - AC-2, AC-3, AC-4 Auxiliary Contacts per
Contactor(1)
(1) Used for electrical interlocking
Cat. No.(2)
(2) Bulletin 104-K reversing contactors are factory assembled and include contactors, mechanical interlock (Cat. No. 100-KMCH) and wiring kit (Cat. No. 100-KPR) for power and control circuit (electrical interlock).
3-phase kW (50 Hz) Hp (60 Hz)
40 °C (104 °F) 230V 400/415V 500V 690V
1-Phase 3-Phase
AC-3 AC-1 115V 230V 200V 230V 460V 575V N.O. N.C.
5 20 1.5 2.2 2.2 2.2 — — 1-1/2 1-1/2 3 3 0 1 104-K05Ä02
9 20 3 4 4 4 — — 2 2 5 5 0 1 104-K09Ä02
12 20 3 5.5 5.5 5.5 — — 3 3 7-1/2 7-1/2 0 1 104-K12Ä02
Screw type terminal versions
AC Voltages [V] 24 110 120 230 240 400 480 600 DC Voltages [V] 12 24 110 125 220 250
50 Hz — D — — — — — — Standard ZQ ZJ ZD ZS ZA ZT
60 Hz — — D — — — B VC with Integrated Diode — DJ — — — —
50/60 Hz KJ — — KF KA KN — —
Spring clamp type terminal versions
AC Voltages [V] 24 110 120 230 DC Voltages [V] 24 110
50 Hz — D — — Standard ZJ ZD
60 Hz — — D — with Integrated Diode DJ —
50/60 Hz KJ — — KF jpeterson Rectangle 9 20 3 4 4 4 1/2 1-1/2 2 2 5 5 jpeterson Rectangle 2 2 1 100-K05Ä200 4 0 1 100-K09Ä400 3 1 1 100-K09Ä300 jpeterson Rectangle 5 20 1.5 2.2 2.2 2.2 1/2 1 1-1/2 1-1/2 3 3 4 0 1 100-K05Ä400 3 1 1 100-K05Ä300 jpeterson Line jpeterson Rectangle 12 20 3 5.5 5.5 5.5 3/4 2 3 3 7-1/2 7-1/2 4 0 1 100-K12Ä400 3 1 1 100-K12Ä300 2 2 1 100-K12Ä200 jpeterson Line jpeterson Line jpeterson Line jpeterson Line jpeterson Line jpeterson Rectangle
ZJ
jpeterson Line jpeterson Line jpeterson Line jpeterson Line jpeterson Line jpeterson Line jpeterson Rectangle
ZJ
jpeterson Line jpeterson Line jpeterson Line jpeterson Line jpeterson Line jpeterson Line
Rockwell Automation Publication 100-TD013I-EN-P - February 2021 7
100-K/104-K Miniature Contactors Product Selection
Assignment of Contacts
Table valid for: AC / DC = 0.85…1.1 x Us, Tamb. = -25 °C…+60 °C (-13…140 °F), normal position (horizontal rail mounting)
Device Combinations in Accordance with IEC 60947-1 / -4-1
Auxiliary Contact Blocks(1) 100-K Miniature Contactors (AC and DC Control)
Circuit Diagram Control
100-K05Ä10 100-K09Ä10 100-K12Ä10
100-K05Ä01 100-K09Ä01 100-K12Ä01
100-K05Ä400 100-K09Ä400 100-K12Ä400
100-K05Ä300 100-K09Ä300 100-K12Ä300
100-K05Ä200 100-K09Ä200 100-K12Ä200
100-KFA02E AC/DC (2) 01 + 02 = 03 (3) (2) (2)(3) —
100-KFC02 AC/DC 10 + 02 = 12 — 00 + 02 = 02 00 + 02 = 02 (3) —
100-KFA11E AC/DC (2) 01 + 11 = 12 (2) (2) (2)
100-KFB11 AC/DC 10 + 11 = 21 — 00 + 11 = 11 00 + 11 = 11 00 + 11 = 11
100-KFC11 AC/DC 10 + 11 = 21 (2) 00 + 11 = 11 00 + 11 = 11 00 + 11 = 11
100-KFA20E AC/DC (2) 01 + 20 = 21 (2) (2) (2)
100-KFC20 AC/DC 10 + 20 = 30 (2) 00 + 20 = 20 00 + 20 = 20 00 + 20 = 20
100-KFA04E AC/DC (2)(3) — (2)(3) — —
100-KFC04 AC/DC 10 + 04 = 14 (3) — 00 + 04 = 04 (3) — —
100-KFA13E AC/DC (2) 01 + 13 = 14 (3) (2) (2)(3) —
100-KFC13 AC/DC 10 + 13 = 23 (2)(3) 00 + 13 = 13 00 + 13 = 13 (3) —
100-KFA22Z AC/DC (2) 01 + 22 = 23 (3) (2) (2)(3) —
100-KFB22 AC/DC 10 + 22 = 32 — 00 + 22 = 22 00 + 22 = 22 (3) —
100-KFC22 AC/DC 10 + 22 = 32 (2)(3) 00 + 22 = 22 00 + 22 = 22 (3) —
100-KFA31Z AC/DC (2) — (2)(4) — —
5A1
A2
K1
5A1
A2
K1
5A1
A2
K1
R8
R7A1
A2
K1
R8
R7A1
A2
K1
R6
R5
51 61
21 31
53 61
54 62
23 31
24 32
53 63
54 64
23 33
24 34
71 81
872 2
51 61
52 62
41 51
42 52
21 31
322 2
53 61 71
7254 62
23 31 41
4224 32
53 83 61 71
7254 84 62
43 53 21 31
3244 54 22
23 53 31 41
4224 54 32
73 83 61
74 84 62
8 Rockwell Automation Publication 100-TD013I-EN-P - February 2021
100-K/104-K Miniature Contactors Accessories
Accessories
100-KFC31 AC/DC 10 + 31 = 41 (4) — 00 + 31 = 31 (4) — —
100-KFA40E AC/DC (2) (2) (2) (2)
100-KFC40 AC/DC 10 + 40 = 50 (2) 00 + 40 = 40 00 + 40 = 40 00 + 40 = 40
(1) For other operating limits, please contact your local Rockwell Automation sales office or Allen-Bradley distributor
(2) Combination possible but not recommended, due to repeating or not consecutive sequence numbering
(3) Tamb max. +40 °C (104 °F)
(4) Tamb max. +40 °C (104 °F) and only allowed for coil voltage 24V DC or 230V AC
Auxiliary Contact Blocks
Description Connection Diagrams
For Use With Pkg. Qty.
Cat. No.
N.O. N.C.
Screw Type Terminals
Spring Clamp Terminals
Front-mounted Auxiliary Contacts
• Auxiliary contact blocks 2- and 4-pole versions
• Choice of contact configurations
• Snap on, no tools required
• Electronic-compatible bifurcated contacts for signals down to 15V/2 mA
• Mirror Contact performance per
IEC 60947-4-1
0 2 100-K05…K12 1 100-KFC02 100-KRFC02
1 1 100-K05…K12 1 100-KFC11 100-KRFC11
2 0 100-K05…K12 1 100-KFC20 100-KRFC20
0 4 100-K05…K12 1 100-KFC04 100-KRFC04
1 3 100-K05…K12 1 100-KFC13 100-KRFC13
3 1 100-K05…K12 1 100-KFC31 100-KRFC31
2 2 100-K05…K12 1 100-KFC22 100-KRFC22
4 0 100-K05…K12 1 100-KFC40 100-KRFC40
Device Combinations in Accordance with IEC 60947-1 / -4-1 (Continued)
Auxiliary Contact Blocks(1) 100-K Miniature Contactors (AC and DC Control)
Circuit Diagram Control
100-K05Ä10 100-K09Ä10 100-K12Ä10
100-K05Ä01 100-K09Ä01 100-K12Ä01
100-K05Ä400 100-K09Ä400 100-K12Ä400
100-K05Ä300 100-K09Ä300 100-K12Ä300
100-K05Ä200 100-K09Ä200 100-K12Ä200
5A1
A2
K1
5A1
A2
K1
5A1
A2
K1
R8
R7A1
A2
K1
R8
R7A1
A2
K1
R6
R5
43 53 31
44 54 32
53 63 73 83
8454 64 74
23 33 43 53
5424 34 44
21 31
23 31
24 32
23 33
24 34
41 51
42 52
21 31
322 2
23 31 41
4224 32
43 53 31
44 54 32
23 53 31 41
4224 54 32
23 33 43 53
5424 34 44
Rockwell Automation Publication 100-TD013I-EN-P - February 2021 9
Front-mounted Auxiliary Contacts
• Auxiliary contact blocks 2- and 4-pole versions
• Choice of contact configurations
• Snap on, no tools required
• Electronic-compatible bifurcated contacts for signals down to 15V/2 mA
• Mirror Contact performance per
IEC 60947-4-1
0 2 100/104-K, 700-K 1 100-KFA02E 100-KRFA02E
1 1 100/104-K, 700-K 1 100-KFA11E 100-KRFA11E
2 0 100/104-K, 700-K
1 100-KFA20E 100-KRFA20E
0 4 100/104-K, 700-K
1 100-KFA04E 100-KRFA04E
1 3 100/104-K, 700-K
1 100-KFA13E 100-KRFA13E
2 2 100/104-K, 700-K
1 100-KFA22Z 100-KRFA22Z
3 1 100/104-K, 700-K 1 100-KFA31Z 100-KRFA31Z
4 0 100/104-K, 700-K 1 100-KFA40E 100-KRFA40E
Control Modules
Description Connection Diagrams
For Use With Pkg. Qty. Cat. No.
Mechanical Interlock
• For interlocking of two adjacent contactors No added width to contactor assembly
• Front mount plug-in type
• Optional auxiliary contact blocks and suppressor modules mount onto the interlock
100/104-K/-KR,
700-K/-KR
1 100-KMCH
Surge Suppressor
• Plug-in type
• Limits surge voltage on coil drop-off
RC Suppressor
24…48V AC
100/104-K/-KR,
700-K/-KR
1(1)
(1) May be ordered in package quantities of 10. Add letter M to the end of the cat. no. Example: 100-KFSC50M.
100-KFSC50
110…280V AC 1(1) 100-KFSC280
380…480V AC 1(1) 100-KFSC480
MOV Suppressor
12…55V AC, 12…77V DC
100/104-K/-KR,
700-K/-KR
1(1) 100-KFSV55
56…136V AC, 78…180V DC 1(1) 100-KFSV136
137…277V AC, 181…250V DC 1(1) 100-KFSV277
Diode Suppressor 12…250V DC
100/104-K/-KR,
700-K/-KR 1(1) 100-KFSD250
Timers
Description Connection Diagrams For Use With Pkg. Qty. Cat. No.
Solid-State Timing Element
• 110…250V AC or DC
• Includes 35 mm Hat Rail adapter
On-Delay, 0.1…3 s
100/104-K, 700-K 10
100-KT3S
On-Delay, 1…30 s
100-KT30S
Auxiliary Contact Blocks (Continued)
Description Connection Diagrams For Use With Pkg. Qty.
Cat. No.
N.O. N.C. Screw Type Terminals
Spring Clamp Terminals
51 61
53 61
54 62
53 63
54 64
71 81
872 2
51 61
52 62
53 61 71
7254 62
53 83 61 71
7254 84 62
73 83 61
74 84 62
53 63 73 83
8454 64 74
S1
N K1
O / I
10 Rockwell Automation Publication 100-TD013I-EN-P - February 2021
Connecting Components
Description For Use With Pkg. Qty. Cat. No.
ECO Connecting Module — 12 A
• For DOL and reversing starters
• Eco-starters mount on single DIN Rail (140M on DIN Rail)
• Electrical and mechanical interconnection of 140M and
100-K contactors
Connects:
140M-C circuit breakers with 100-K contactors
140M-C to 100-K 1(1)
(1) May be ordered in package quantities of 10. Add letter M to the end of the cat. no. Example: 140M-C-PEK12M.
140M-C-PEK12
Power Wiring Kit
• For Reversing and Star/Delta combinations. Star-point bridge not included.
• Min. interruption time 50 ms
100-K 1 100-KPR
Feeder Terminal for Compact Bus Bars
• Max. current 34 A
Supply of compact bus bars 100-K 1 100-KWT
Three-phase Compact Bus Bars
• Max. current 34 A
• For 100-K, 5…12 A contactors
45 mm spacing (3 connections)(2)
(2) Combinations possible. Example: For 6 contactor connections use one cat. no. 100-KW453 and one cat. no. 100-KW454.
100-K, 5…12 A 1 100-KW453
45 mm spacing (4 connections)(2) 100-K, 5…12 A 1 100-KW454
Marking Systems
Description Pkg. Qty. Cat. No.
Label Sheet
• 105 self-adhesive paper labels each, 6 x 17 mm
10 100-FMS
Snap-In Marker Card 5 1492-M6X12
2 4 6
1 3 5
K1M
2 4 6
1 3 5
K2M
- (L2)
Rockwell Automation Publication 100-TD013I-EN-P - February 2021 11
100-K/104-K Miniature Contactors Specifications
Specifications
Table 1 - Main Circuits
100-KR 100/104-K
05 09 05 09 12
AC-1 Active Power Load (50 Hz); Ambient temperature 40 °C (104 °F)
Rated Operational Current, Ie
≤ 500V [A] 10 10 20 20 20
690V [A] 10 10 20 20 20
Rated Operational Power, Pe
230V [kW] 4 4 8 8 8
240V [kW] 4 4 8.3 8.3 8.3
400V [kW] 6.9 6.9 14 14 14
415V [kW] 7 7 14 14 14
500V [kW] 8.7 8.7 17 17 17
690V [kW] 12 12 24 24 24
AC-1 Active Power Load (50 Hz); Ambient temperature 60 °C (140 °F)
Rated Operational Current, Ie
≤ 500V [A] 10 10 16 16 16
690V [A] 10 10 16 16 16
Rated Operational Power, Pe
230V [kW] 4 4 6.4 6.4 6.4
240V [kW] 4 4 6.7 6.7 6.7
400V [kW] 6.9 6.9 11 11 11
415V [kW] 7 7 12 12 12
500V [kW] 8.7 8.7 14 14 14
690V [kW] 12 12 19 19 19
Switching of 3-phase Motors; (50 Hz) Ambient temperature 60 °C (140 °F), AC-2, AC-3
Rated Operational Current, Ie
230V [A] 6.3 8.5 6.3 11.3 11.3
240V [A] 6.3 8.5 6.3 11.3 11.3
400V [A] 4.9 8.5 4.9 8.5 11.5
415V [A] 4.9 8.5 4.9 8.5 11.5
500V [A] 3.9 6.8 3.9 6.8 9.2
690V [A] 2.8 4.9 2.8 4.9 6.7
Rated Operational Power, Pe
230V [kW] 1.5 2.2 1.5 3 3
240V [kW] 1.5 2.2 1.5 3 3
400V [kW] 2.2 4 2.2 4 5.5
415V [kW] 2.2 4 2.2 4 5.5
500V [kW] 2.2 4 2.2 4 5.5
690V [kW] 2.2 4 2.2 4 5.5
Load Carrying Capacity per UL/CSA
General Purpose Current (enclosed)
[A] 9 9 12 15 18
Rated current (enclosed), 1-phase
115V [A] 7.2 7.2 9.8 9.8 13.8
230V [A] 6.9 8 8 10 12
Rated power (enclosed), 1-phase
115V [Hp] 1/3 1/3 0.5 0.5 0.75
230V [Hp] 3/4 1 1 1.5 2
Rated current (enclosed), 3-phase
200V [A] 6.9 7.8 6.9 7.8 11
230V [A] 6 6.8 6 6.8 9.6
460V [A] 4.8 7.6 4.8 7.6 11
575V [A] 3.9 6.1 3.9 6.1 9
Rated power (enclosed), 3-phase
200V [Hp] 1.5 2 1.5 2 3
230V [Hp] 1.5 2 1.5 2 3
460V [Hp] 3 5 3 5 7.5
575V [Hp] 3 5 3 5 7.5
Table 2 - Main Circuits
100/104-K 05 09 12
Switching of 3-phase Motors, (50 Hz); Ambient temperature 60 °C (140 °F), AC-4
Rated Operational Current, Ie
230V [A] 6.3 11.3 11.3
240V [A] 6.3 11.3 11.3
400V [A] 4.9 8.5 11.5
415V [A] 4.9 8.5 11.5
500V [A] 3.9 6.8 9.2
690V [A] 2.8 4.9 6.7
Rated Operational Power, Pe
230V [Hp] 1.5 3 3
240V [Hp] 1.5 3 3
400V [Hp] 2.2 4 5.5
415V [Hp] 2.2 4 5.5
500V [Hp] 2.2 4 5.5
690V [Hp] 2.2 4 5.5
AC-4 at approximately 200,000 operations
Rated Operational Current, Ie
230V [A] 2.3 3.9 3.9
240V [A] 2.3 3.9 3.9
400/415V [A] 2 3.6 3.6
500V [A] 1.9 3.2 3.2
Rated Operational Power, Pe
230V (1)
(1) Power ratings at 50 Hz: Preferred values according to IEC 60072-1
[Hp] 0.37 0.75 0.75
240V (1) [Hp] 0.37 0.75 0.75
400V (1) [Hp] 0.75 1.5 1.5
415V (1) [Hp] 0.75 1.5 1.5
500V (1) [Hp] 0.75 1.5 1.5
Max. switching frequency Ops/hour 250 250 250
Wye-Delta (60 Hz)
Rated Operational Power, Pe
200V [Hp] 2.2 3 5
230V [Hp] 2.2 3 5
460V [Hp] 5 7.5 10
575V [Hp] 5 7.5 10
Star-Delta Starting (50 Hz)
Rated Operational Current, Ie
≤ 230V [A] 11.3 20 20
≤ 240V [A] 11.3 20 20
400V [A] 8.5 15.5 15.5
415V [A] 8.5 15.5 15.5
500V [A] 6.8 12.4 12.4
690V [A] 4.9 8.9 8.9
Rated Operational Power, Pe
230V (1) [kW] 3 5.5 5.5
240V (1) [kW] 3 5.5 5.5
400V (1) [kW] 4 7.5 7.5
415V (1) [kW] 4 7.5 7.5
500V (1) [kW] 4 7.5 7.5
690V (1) [kW] 4 7.5 7.5
12 Rockwell Automation Publication 100-TD013I-EN-P - February 2021
Table 3 - Main Circuits
100/104-K 05 09 12
Switching of Power Transformers, AC-6a (50 Hz) n= 30
≤ 230V [A] 2.9 5.4 5.4
≤ 240V [A] 2.9 5.4 5.4
≤ 400V [A] 2.4 4.1 5.4
≤ 415V [A] 2.4 4.1 5.4
≤ 500V [A] 1.8 3.2 3.2
Apparent Power
230V [kVA] 1.2 2 2
240V [kVA] 1.2 2 2
400V [kVA] 1.7 2.8 3.4
415V [kVA] 1.7 2.8 3.4
500V [kVA] 1.7 2.8 3.4
690V [kVA] 2 4 5
Switching of Lamps
Gas discharge lamps AC-5a, 40 °C (104 °F) open [A] 18 18 18 enclosed [A] 14.5 14.5 14.5
Individually compensated:
Max. capacitance at expected
Short-circuit current of 10 kA [µF] 750 750 750
20 kA [µF] 400 400 400
Filament AC-5b 230/240V [A] 5 9 9
Switching of Low Inductive Loads in Home Appliances and Similar Applications per IEC 61095 (50 Hz)
AC-7a 230V [A] 20 20 20
400V [A] 20 20 20
Switching of Motor Load for Home Appliances (50 Hz)
AC-7b 230V [A] 6 11 11
400V [A] 6 11 11
Switching of Hermetically Sealed Cooling Compressor Motors - manual reset of overload release (50 Hz)
AC-8a 400V [A] 11 18 18
500V [A] 10 15 15
Switching of DC Loads
Non-inductive or slightly inductive loads or resistance furnaces
DC-1, 60 °C (140 °F)
1 pole
24V [A] 6 9 9
48/60V [A] 4/1 6/1.5 6/1.5
110V [A] 0.6 1 1
220V [A] 0.2 0.3 0.3
440V [A] 0.08 0.1 0.1
2 poles in series
24V [A] 6 9 9
48/60V [A] 6 8 8
110V [A] 4 6 6
220V [A] 0.8 1.2 1.2
440V [A] 0.2 0.3 0.3
3 poles in series
24V [A] 6 9 9
48/60V [A] 6 9 9
110V [A] 6 9 9
220V [A] 3 4 4
440V [A] 0.4 0.6 0.6
Inrush Current
Rated transformer current = n
Shunt-wound Motors Starting, reverse current braking, reversing, stepping DC-3, 60 °C (140 °F)
3 poles in series
24V [A] 5 9 9
48/60V [A] 4 6 6
110V [A] 2 3 3
220V [A] 0.8 1.2 1.2
440V [A] 0.15 0.2 0.2
Series-wound Motors Starting, reverse current braking, reversing, stepping DC-5, 60 °C (140 °F)
3 poles in series
24V [A] 5 9 9
48/60V [A] 2 3 3
110V [A] 0.6 1 1
220V [A] 0.1 0.1 0.1
Short Time Withstand ICW, 60 °C (140 °F
10 s [A] 60 96 96
Resistance and Power Dissipation
Main current circuit resistance [mΩ] 2.2 2.2 2.2
Power dissipation by all circuits at Ie AC-3/ 400V
[W] 0.3 0.9 0.9
Total power dissipation
At Ie AC-3/400V AC control [W] 2.1 2.7 2.7
DC control (electronic) [W] 2.9 3.5 3.5
Lifespan
Mechanical AC control [Million operations] 15 15 15
Mechanical DC control [Million operations] 15 15 15
Electrical AC-3 (400 V) [Million operations] 0.7 0.7 0.7
Weight
AC
Non-Rev. [kg (lbs.)] 0.16 (0.35)
Rev. [kg (lbs.)] 0.4 (0.88)
DC
Non-Rev. [kg (lbs.)] 0.2 (0.44)
Rev. [kg (lbs.)] 0.48 (1.06)
Table 4 - Conductors
100-KR 100/104-K
05 09 05 09 12
Conductor Cross Sections - Main Contacts Terminal type
(1)
(1) Pozidriv No. 2 / Blade No. 3 screw
1 conductor [mm2] 0.50…2.5 0.75…2.5
2 conductors [mm2] 0.50…2.5 0.75…2.5
1 conductor [mm2] 0.75…2.5 (2)
(2) Fine- or coarse-stranded only
1…4
2 conductors [mm2] 0.75…2.5 (2) 1…2.5+ 1…4
Recommended torque [N•m] — 1.2
Cross section per UL/CSA [AWG] 18…14(2) 18…12
Recommended torque [lb•in] — 10.6
Table 3 - Main Circuits (Continued)
100/104-K 05 09 12
Rockwell Automation Publication 100-TD013I-EN-P - February 2021 13
Table 5 - Short-Circuit Coordination Data(1)
(1) See the Rockwell Automation Global SCCR Tool at rok.auto/sccr for complete short-circuit current ratings.
100/104-K 05 09 12
Short Circuit Coordination (Max. Fuse or Circuit Breaker Rating) Per IEC 60947-4-1 (contactor and fuses only)
DIN Fuses- gG, gL 50 kA Available Fault Current
Type "1" (690V) [A] 35 35 35
Type "2" (400V) [A] 16 20 20
Per UL 508 and CSA 22.2 No. 14 (contactor and fuses or circuit breaker only)
UL Class K5 and RK5 Fuses 5 kA Available Fault Current
UL Listed Combination (600V) [A] 40 40 40
UL Class CC and CSA HRCI-MISC Fuses 50 kA Available Fault Current
UL Listed Combination (600V) [A] 30 30 30
UL Class J and CSA HRCI-J Fuses 50 kA Available Fault Current
UL Listed Combination (600V) [A] 30 30 30
Table 6 - Coil Data
100/104-K 05 09 12
Operating Limits
50 Hz, 60 Hz, 50/60 Hz pick-up [x Us] 0.85…1.1 dropout [x Us] 0.2…0.75
DC (conventional) pick-up [x Us]
0.8…1.1
0.7…1.25(1)
(1) For 9, 12, 24, and 110V DC coils dropout [x Us] 0.1…0.75
Coil Consumption
50 Hz, 60 Hz, 50/60 Hz pick-up [VA] 35 hold-in [VA/W] 5/1.8
DC (conventional) pick-up [W] cold 3.0, warm 2.6 hold-in [W] cold 3.0, warm 2.6
Operating Times
AC
closing delay [ms] 15…40 opening delay [ms] 15…33
With RC module closing delay [ms] 15…28
DC (conventional) opening delay [ms] 18…40 closing delay [ms] 6…12
With integrated diode opening delay [ms] 8…12
With external diode opening delay [ms] 35…50
Table 7 - Auxiliary Contacts and Auxiliary Contact Blocks
Conventional Coils Internal Front mounted
Switching of AC Loads
AC-12 Ith at 40 °C (104 °F) [A] 10 10 at 60 °C (140 °F) [A] 6 6
AC-15 at rated voltage of
24V [A] 6 3
42/48V [A] 6 3
120V [A] 6 3
230V [A] 3 2
240V [A] 3 2
400V [A] 1.8 1.2
415V [A] 1.8 1.2
500V [A] 1.4 1.0
690V [A] 1.0 0.6
Switching of DC Loads
DC-12 L/R < 1 ms resistive loads at
24V DC [A] 6 —
48V DC [A] 4 —
110V DC [A] 0.6 —
220V DC [A] 0.2 —
440V DC [A] 0.08 —
DC-14L/R <15 ms inductive loads with economy resistor in series at
24V DC [A] 4 —
48V DC [A] 2.5 —
110V DC [A] 0.4 —
220V DC [A] 0.12 —
440V DC [A] 0.05 —
DC-13 switching electromagnets at
24V DC [A] 2.8 2.3
48V DC [A] 1.2 1
110V DC [A] 0.55 0.55
220V DC [A] 0.27 0.27
440V DC [A] 0.15 0.15
Fuse gG [A] 10 10
[A] 10 10
Min. switching capacity according to IEC 60947-5-4 15V/ 10 mA 15V/ 2 mA
Load Carrying Capacity per UL/CSA
Rated voltage AC [V] max.600
Continuous rating at 40 °C (104 °F) [A] 10
Switching capacity AC [A] A600 B600
Rated voltage DC [V] max.600
Switching capacity DC [A] Q600
14 Rockwell Automation Publication 100-TD013I-EN-P - February 2021
Table 8 - General
Attribute Value
Rated Isolation Voltage Ui
IEC [V] 690
UL, CSA [V] 600
Rated Impulse Voltage Withstand Uimp
[kV] 6
Rated Voltage Ue
AC 50/60 Hz [V] 230, 240, 400, 415, 460, 500, 575, 690
DC [V] 24, 48, 110, 220, 440
Insulation Class of the Coil Class F per IEC 60085
Class 105 insulation system per
UL 508
Rated coil frequency AC 50/60 Hz, DC
Ambient Temperature
Storage [ °C ( °F)] -55…+80 (-67…176)
Operation at rated voltage [ °C ( °F)] -25…+60 (-13…140) at 70 °C (158 °F) 15% current reduction against 60 °C
(140 °F) values
Climatic Withstand IEC60068-2-30
Max. Altitude of Installation Site [m] 2000 NN, per IEC60947-4
Protection Class IP2X
Single contactor cover —
Contactor with frame terminal block —
Auxiliary contact IP2X
Protection against Accidental Contact —
Resistance to Shock IEC60068-2
Resistance to Vibration IEC60068-2
Mechanically Linked Contacts IEC60947-5-1,AnnexL
100-K… (on main device)
Mirror Contacts IEC60947-4 Annex F 100-K…+100-KF…
Table 9 - Standards Compliance and Certifications
Standards Compliance Certifications
IEC/EN 60947-1,-4-1,-5-1,-5-4 CE Marked
UL 508 CCC
CSA 22.2. No. 14 cULus Listed (File No. E41850, Guide NLDX, NLDX7)
NF F 62-000
Meets the material restrictions for European Directive 2002/95/IEC-EU-RoHS
Rockwell Automation Publication 100-TD013I-EN-P - February 2021 15
100-K/104-K Miniature Contactors Life-Load Curves
Life-Load Curves Figure 1 - AC-3, Switching of squirrel-cage motors while starting /AC-1, Non- or slightly inductive loads, resistance furnaces
Figure 2 - AC-4, Stepping of squirrel-cage motors
100-K05
100-K09
100-K12
0.01
1 10 100
0.1
Rated current Ie AC-3 [A] (Dashed curves - - - - AC-1 only, open)
C o n ta c t L ife m ill io n s o f o p e ra tio n s)
Electrical life; Ue = 400…460V AC
0.01
0.1 1 10
0.1
100-K05
100-K09; 100-K12
Rated current Ie AC-4 [A]
C o n ta ct L ife m ill io n s o f o p e ra ti o n s)
Electrical life; Ue = 400…460V AC
16 Rockwell Automation Publication 100-TD013I-EN-P - February 2021
100-K/104-K Miniature Contactors Approximate Dimensions
Approximate Dimensions
Dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.
Figure 3 - 100-K Miniature Contactor with 193-K Overload Relay
Figure 4 - Mounting Position
49 (1-15/16)
4 (5/32)
.2
-1 /4
) 5
-1
/6
-1 /8
35 (1-25/64)
44.9 (1-25/32)
-3
/3
63.5 (2-1/2)
78.7 (3-7/64)
35.2 (1-25/64)
.2
-1
/1
36.9 (1-29/64)
-Minimum distance to grounded parts or walls
180°
Rockwell Automation Publication 100-TD013I-EN-P - February 2021 17
100-C/104-C, 100S-C/104S-C, 100Q-C Contactors
Product Selection—100-C/104-C Contactors
• Compact sizes from 4…55 kW/5…75 Hp (9…97 A)
• Common accessories for all contactor sizes
• Front and side mounting of auxiliary contacts
• Electronic and pneumatic timing modules
• Space-saving coil-mounted control modules
• Reversible coil terminations (line or load side)
• All devices can be attached to 35 mm DIN mounting Rail
• Environmentally friendly materials
The Bulletin 100-C/104-C IEC contactor family, along with a wide range of common accessories and Bulletin 193 solid-state overload relays, provides the most compact and flexible starter component system available.
Ä Coil voltage code and terminal position—see page 19
3-Pole AC- and DC-operated Contactors
Rated Operational Current Ie [A] Ratings for switching AC motors - AC-2, AC-3, AC-4 Auxiliary Contacts
Cat. No.(1)
(1) For screwless terminals on 100-C09…C16, add an “R” after the letter “C” in the catalog number. Example: Cat. No. 100-C09Ä10 becomes 100-CR09Ä10. The AC-1 rating for the 100-CR is limited to 25 A.
3-phase kW (50 Hz) Hp (60 Hz)
40 °C (104 °F) 230V 400/415V 500V 690V
1-Phase 3-Phase
AC-3 AC-1 115V 230V 200V 230V 460V 575V N.O. N.C.
9 32 3 4 4 4 1/2 1-1/12 2 2 5 7-1/12 1 0 100-C09Ä10
0 1 100-C09Ä01
12 32 4 5.5 5.5 5.5 1/2 2 3 3 7-1/2 10 1 0 100-C12Ä10
0 1 100-C12Ä01
16 32 5.5 7.5 7.5 7.5 1 3 5 5 10 15 1 0 100-C16Ä10
0 1 100-C16Ä01
23 32 7.5 11 13 10 2 3 5 7-1/2 15 15 1 0 100-C23Ä10
0 1 100-C23Ä01
30 65 10 15 15 15 2 5 7-1/2 10 20 25
0 0 100-C30Ä00
1 0 100-C30Ä10
0 1 100-C30Ä01
37 65 11 18.5/20 20 18.5 3 5 10 10 25 30
0 0 100-C37Ä00
1 0 100-C37Ä10
0 1 100-C37Ä01
43 85 13 22 25 22 3 7-1/2 10 15 30 30
0 0 100-C43Ä00
1 0 100-C43Ä10
0 1 100-C43Ä01
55 85 15 30 30 30 5 10 15 20 40 40
0 0 100-C55Ä00
1 0 100-C55Ä10
0 1 100-C55Ä01
60 100 18.5 32 37 32 5 10 15 20 40 50
0 0 100-C60Ä00
1 0 100-C60Ä10
0 1 100-C60Ä01
72 100 22 40 45 40 5 15 20 25 50 60
0 0 100-C72Ä00
1 0 100-C72Ä10
0 1 100-C72Ä01
85 100 25 45 55 45 7-1/2 15 25 30 60 60
0 0 100-C85Ä00
1 0 100-C85Ä10
0 1 100-C85Ä01
97 130 30 55 55 55 10 20 30 30 75 75
0 0 100-C97Ä00
1 0 100-C97Ä10
0 1 100-C97Ä01
100-C Contactor 104-C Reversing Contactor jpeterson Rectangle 100-C Contactor jpeterson Line jpeterson Line jpeterson Rectangle 30 65 10 15 15 15 2 5 7-1/2 10 20 25 0 0 100-C30Ä00 1 0 100-C30Ä10 jpeterson Text Box
ALLEN-BRADLEY 100-C30EJ10
jpeterson Rectangle 9 32 3 4 4 4 1/2 1-1/12 2 2 5 7-1/12 1 0 100-C09Ä10 0 1 100-C09Ä01 12 32 4 5.5 5.5 5.5 1/2 2 3 3 7-1/2 10 1 0 100-C12Ä10 0 1 100-C12Ä01 16 32 5.5 7.5 7.5 7.5 1 3 5 5 10 15 1 0 100-C16Ä10 0 1 100-C16Ä01 23 32 7.5 11 13 10 2 3 5 7-1/2 15 15 1 0 100-C23Ä10 0 1 100-C23Ä01 0 0 100-C30Ä00 jpeterson Line jpeterson Line jpeterson Rectangle 0 1 100-C30Ä01 37 65 11 18.5/20 20 18.5 3 5 10 10 25 30 0 0 100-C37Ä00 1 0 100-C37Ä10 0 1 100-C37Ä01 43 85 13 22 25 22 3 7-1/2 10 15 30 30 0 0 100-C43Ä00 1 0 100-C43Ä10 0 1 100-C43Ä01 55 85 15 30 30 30 5 10 15 20 40 40 0 0 100-C55Ä00 1 0 100-C55Ä10 0 1 100-C55Ä01 60 100 18.5 32 37 32 5 10 15 20 40 50 0 0 100-C60Ä00 1 0 100-C60Ä10 0 1 100-C60Ä01 72 100 22 40 45 40 5 15 20 25 50 60 0 0 100-C72Ä00 1 0 100-C72Ä10 0 1 100-C72Ä01 85 100 25 45 55 45 7-1/2 15 25 30 60 60 0 0 100-C85Ä00 1 0 100-C85Ä10 0 1 100-C85Ä01 97 130 30 55 55 55 10 20 30 30 75 75 0 0 100-C97Ä00 1 0 100-C97Ä10 0 1 100-C97Ä01 jpeterson Line
Rockwell Automation Publication 100-TD013I-EN-P - February 2021 19
100-C/104-C, 100S-C/104S-C, 100Q-C Contactors Product Selection—100-C/104-C Contactors
Coil Voltage Codes
The Cat. No. as listed is incomplete. Select a coil voltage code from the table below to complete the Cat. No. Example: 120V, 60 Hz: Cat. No.
100-C09Ä10 becomes Cat. No.100-C09D10.
Coil Terminal Position
All contactors are delivered with the coil terminals located on the line side.
For load side coil terminations, insert a “U” prior to the coil voltage code. Ordering example: Cat. No. 100-C09UD10.
AC Voltages [V] 12 24 32 36 42 48 100 100…
110 120 127 200
200…
208…
50 Hz R K V W X Y KP — D P S KG L — —
60 Hz Q J — V — X — KP — D — — KG H L
50/60 Hz — KJ — — — KY KP — KD — — KG KL(1)
(1) Not available on 100/104-C90 or -C97 contactors.
AC Voltages [V] 220…
230…
240 277 347 380 380…
400…
440 480 500 550 600
50 Hz F — VA T — — — N — G B — M C —
60 Hz — — — A T I E — — — N B — — C
50/60 Hz KL(1)
(1) Not available on 100/104-C90 or -C97 contactors.
KF — KA — — — — KN — KB — — — —
DC Voltages [V] 9 12 24 24 36 36…48 48 48…72 60 64
100-C09…C55 Electronic with Integrated Diode
— EQ EJ QJ(1)
(1) “QJ” coil has faster dropout time (16…21 ms).
— EW — EY — —
100-C60…C97 with Integrated Diode DR DQ DJ — DW — DY — DZ DB
DC Voltages [V] 72 80 110 110…125 115 125 220 220…250 230 250
100-C09…C55 Electronic with Integrated Diode
— — — ED — — — EA — —
100-C60…C97 with Integrated Diode DG DE DD — DP DS DA — DF DT
Cat. No.100-C09Ä10 Line Side Cat. No.100-C09UÄ10 Load Side jpeterson Line jpeterson Line jpeterson Line jpeterson Line jpeterson Line jpeterson Line jpeterson Line jpeterson Line jpeterson Line jpeterson Line jpeterson Line jpeterson Line jpeterson Line jpeterson Line jpeterson Line jpeterson Line jpeterson Rectangle
EJ
20 Rockwell Automation Publication 100-TD013I-EN-P - February 2021
Assignment of Contacts
Table valid for: AC / DC = 0.85…1.1 x Us, Tamb = -25 °C…+60 °C (-13…140 °F), normal position (horizontal rail mounting)
Device Combinations in Accordance with IEC 60947-1 / -4-1
Auxiliary Contact Blocks 100-C Contactors (AC and DC Control)
Circuit Diagram Control
100-C09_Ä10 100-C12_Ä10 100-C16_Ä10 100-C23_Ä10
100-C09_Ä01 100-C12_Ä01 100-C16_Ä01 100-C23_Ä01
100-C30_Ä00 100-C37_Ä00 100-C43_Ä00 100-C55_Ä00 100-C60_Ä00 100-C72_Ä00 100-C85_Ä00 100-C97_Ä00
100-C09_Ä400 100-C12_Ä400 100-C16_Ä400 100-C23_Ä400 100-C40_Ä400 100-C90_Ä400
100-C09_Ä300 100-C12_Ä300 100-C16_Ä300 100-C23_Ä300
100-C09_Ä200 100-C12_Ä200 100-C16_Ä200 100-C23_Ä200 100-C40_Ä200 100-C90_Ä200
Side Mounting (1)
(1) Up to 8 auxiliary contacts possible: contactor + front mounted (AC max. 4 N.C. / DC max. 4 N.C.), side mounted (AC max. 2 N.O. / DC max. 2 N.O. and max. 2 N.C.).
100-SB01 AC/DC 10 + 01 = 11 01 + 01 = 02 (2)
(2) Double numbering: because of double numbering only left-side mounting is recommended.
00 + 01 = 01 00 + 01 = 01 00 + 01 = 01 00 + 01 = 01
100-SB10 AC/DC 10 + 10 = 20 (2) 01 + 10 = 11 00 + 10 = 10 00 + 10 = 10 00 + 10 = 10 00 + 10 = 10
100-SB02 AC/DC 10 + 02 = 12 (2) — 00 + 02 = 02 00 + 02 = 02 00 + 02 = 02 00 + 02 = 02
100-SB11 AC/DC 10 + 11 = 21 (2) 01 + 11 = 12 (2) 00 + 11 = 11 00 + 11 = 11 00 + 11 = 11 00 + 11 = 11
100-SB20 AC/DC 10 + 20 = 30 (2) 01 + 20 = 21 (2) 00 + 20 = 20 00 + 20 = 20 00 + 20 = 20 00 + 20 = 20
100-SBL11 (3)
(3) Early make and/or late break.
AC/DC 10 + L11 = L21 (2) 01 + L11 = L12 (2) 00 + L11 = L11 00 + L11 = L11 00 + L11 = L11 00 + L11 = L11
5A1
A2
K1
5A1
A2
K1
5A1
A2
K1
5A1
A2
K1
R8
R7A1
A2
K1
R6
R5A1
A2
K1
R4
R3
213242
213244
233444
25361748
1847 2635
Rockwell Automation Publication 100-TD013I-EN-P - February 2021 21
Device Combinations in Accordance with IEC 60947-1 / -4-1
Auxiliary Contact Blocks 100-C Contactors (AC and DC Control)
Circuit Diagram
Control
100-C09_Ä10 100-C12_Ä10 100-C16_Ä10 100-C23_Ä10
100-C09_Ä01 100-C12_Ä01 100-C16_Ä01 100-C23_Ä01
100-C30_Ä00 100-C37_Ä00 100-C43_Ä00 100-C55_Ä00 100-C60_Ä00 100-C72_Ä00 100-C85_Ä00 100-C97_Ä00
100-C09_Ä400 100-C12_Ä400 100-C16_Ä400 100-C23_Ä400 100-C40_Ä400 100-C90_Ä400
100-C09_Ä300 100-C12_Ä300 100-C16_Ä300 100-C23_Ä300
100-C09_Ä200 100-C12_Ä200 100-C16_Ä200 100-C23_Ä200 100-C40_Ä200 100-C90_Ä200
Front Mounting (1)
(1) Up to 8 auxiliary contacts possible: contactor + front mounted (AC max. 4 N.C. / DC max. 4 N.C.), side mounted (AC max. 2 N.O. / DC max. 2 N.O. and max. 2 N.C.).
100-FA02,
100-FAB02
AC/DC 10 + 02 = 12 01 + 02 = 03 00 + 02 = 02 00 + 02 = 02 00 + 02 = 02 00 + 02 = 02
100-FA11,
100-FAB11
AC/DC 10 + 11 = 21 01 + 11 = 12 00 + 11 = 11 00 + 11 = 11 00 + 11 = 11 00 + 11 = 11
100-FB11,
100-FBB11
AC/DC — — 00 + 11 = 11 00 + 11 = 11 00 + 11 = 11 00 + 11 = 11
100-FC11,
100-FCB11 AC/DC 10 + 11 = 21 — — — — —
100-FA20,
100-FAB20
AC/DC 10 + 20 = 30 01 + 20 = 21 00 + 20 = 20 00 + 20 = 20 00 + 20 = 20 00 + 20 = 20
100-FBL11 (2)
(2) Early make and/or late break.
AC/DC — — 00 + L11 = L11 00 + L11 = L11 00 + L11 = L11 00 + L11 = L11
100-FA22,
100-FAB22 AC/DC 10 + 22 = 32 01 + 22 = 23 00 + 22 = 22 00 + 22 = 22 00 + 22 = 22 00 + 22 = 22
100-FB22,
100-FBB22
AC/DC — — 00 + 22 = 22 00 + 22 = 22 00 + 22 = 22 00 + 22 = 22
100-FC22,
100-FCB22
AC/DC 10 + 22 = 32 — — — — —
100-FA31,
100-FAB31 AC/DC 10 + 31 = 41 01 + 31 = 32 00 + 31 = 31 00 + 31 = 31 00 + 31 = 31 00 + 31 = 31
100-FA40,
100-FAB40 AC/DC 10 + 40 = 50 01 + 40 = 41 00 + 40 = 40 00 + 40 = 40 00 + 40 = 40 00 + 40 = 40
100-FAL22 (2) AC/DC 10 + L22 = L32 01 + L22 = L23 00 + L22 = L22 00 + L22 = L22 00 + L22 = L22 00 + L22 = L22
100-FA04,
100-FAB04
AC/DC 10 + 04 = 14 01 + 04 = 05 00 + 04 = 04 00 + 04 = 04 00 + 04 = 04 00 + 04 = 04
100-FA13,
100-FAB13 AC/DC 10 + 13 = 23 01 + 13 = 14 00 + 13 = 13 00 + 13 = 13 00 + 13 = 13 00 + 13 = 13
100-FB02,
100-FBB02 AC/DC 10 + 02 = 12 01 + 02 = 03 00 + 02 = 02 00 + 02 = 02 00 + 02 = 02 00 + 02 = 02
100-FB20,
100-FBB20 AC/DC 10 + 20 = 30 01 + 20 = 21 00 + 20 = 20 00 + 20 = 20 00 + 20 = 20 00 + 20 = 20
100-FC31,
100-FCB31 AC/DC 10 + 31 = 41 01 + 31 = 32 00 + 31 = 31 00 + 31 = 31 00 + 31 = 31 00 + 31 = 31
5A1
A2
K1
5A1
A2
K1
5A1
A2
K1
5A1
A2
K1
R8
R7A1
A2
K1
R6
R5A1
A2
K1
R4
R3
51 61
53 61
54 62
13 21
14 22
23 31
24 32
53 63
54 64
17 25
53 61 71
7254 62
13 21 31
3214 22
43321 1
22 4432
53 61
54 62
53 63 73 83
8454 64 74
53 61 75
7654 62
51 61 71 81
8252 62 72
53 61 71 81
8254 62 72
11 21
12 22
13 23
23 31 43 53
5424 32 44
56 Rockwell Automation Publication 700-TD552F-EN-P - January 2021
Relay and Timer Specifications
700-HL 2-pole Terminal Block Relay
• Relay and socket assembled interface modules for high density interposing or isolation applications
• Screw terminal and spring-clamp bases
• 10 A relay, choice of silver or gold contacts
• DPDT (relay)
• Built-in retainer clip and snap-in marker lever
• Standard LED, reverse polarity protection, and surge protection
• Externally replaceable relay modules
Accessories - 700-HL Relays (2- pole)
Output Type DPDT (2 C/O); Ith = 10 A
Recommended Tightening Torque 0.6 N•m max. (5.3 lb•in.)
Wire Range Screw Terminal: 0.2…2.5 mm2 (#24…14 AWG), Spring Terminal: 0.2…2.5 mm2 (#24…14 AWG)
Approvals cULus, cURus, CE
Input Voltages Pkg. Quantity Cat. No.(1) (Screw Terminals)
(1) For Gold-plated contacts: Add the letter "X" at the end of the catalog number. Example: Cat. No. 700-HLT12Z24 with gold plated contacts is Cat. No. 700-HLT12Z24X. The following relays are available with the gold-plated contact option: 700-HLT_2Z24, 700-HLT_2U24, 700-HLT_2U1, and 700-HLT_2U2. Not available on 12V and 48V DC products.
Cat. No.(Spring Clamp Terminals)
12V DC 10 700-HLT12Z12 700-HLT22Z12
24V DC 10 700-HLT12Z24 700-HLT22Z24
48V DC 10 700-HLT12Z48 700-HLT22Z48
24V AC/DC 10 700-HLT12U24 700-HLT22U24
110/125V AC/DC 10 700-HLT12U1 700-HLT22U1
220…240V AC/DC 10 700-HLT12U2 700-HLT22U2
Photo Description Pkg.
Qty.
Socket Input Voltage/Color Cat. No.
Replacement Relays Order must be for 20 relays or multiples of 20.
12V DC 700-TBR212
24V AC/DC 700-TBR224
48V DC 700-TBR248
110/125V AC/DC, 220…240V AC/DC 700-TBR2110
8-Way Jumper Can be cut to required length. Ith = 10 A max per 8-way jumper.
Red 700-TBJ08R
Grey 700-TBJ08G
Blue 700-TBJ08B
End Barrier Used for visual inspection of groups, safe separation of neighboring 700-HL modules that end with jumpers.
10 Black 700-HN177
Snap-in Marker(1)
These snap-in markers have a 6 x 12 mm surface and snap into the ejection lever for the relay.
(1) For custom markers, contact your local Rockwell Automation sales office or Allen-Bradley distributor for more information.
100 Blank 1492-MS6X12 jpeterson Text Box
ALLEN-BRADLEY 700-HLT12U24
jpeterson Rectangle
48V DC 10 700-HLT12Z48 700-HLT22Z48
24V AC/DC 10 700-HLT12U24 700-HLT22U24
110/125V AC/DC 10 700-HLT12U1 700-HLT22U1
jpeterson Line jpeterson Line jpeterson Line jpeterson Line
Rockwell Automation Publication 700-TD552F-EN-P - January 2021 57
Specifications - 700-HL Relays (2-Pole)
Cat. No. 700-HLT…2-Pole (Relay Output)
Electrical Ratings
Pilot Duty Rating B 300, R 300
Rated Thermal Current (Ith) 2-Pole — 10 A
Rated Insulation Voltage (Ui) 250V IEC, 300V UL/CSA
Contacts
Inductive V AC
UL
120V AC AC-15, 3.0A B 300, 3.0 A 1/4 HP (186 W), 1-phase
240V AC
AC-15, 3.0 A
B 300, 1.5 A
1/2 HP (373 W), 1-phase
Inductive V DC
24V DC DC-13, 2.0 A
125V DC DC-13, 0.3 A
250V DC DC-13, 0.2 A
Resistive Make, Break, and Continuous
250V AC 10 A
24V DC 10 A
250V DC 0.28 A
Min. Permissible Contact Ratings 12V, 10 mA (120 mW) for Silver Contacts, 5V, 1 mA (50 mW) for Gold Contacts
Permissible Coil Voltage Variation Pickup:
85…110% of Nominal Voltage at 50 Hz 85…110% of Nominal Voltage at 60 Hz
80…110% of Nominal Voltage at DC
Must Dropout Voltage:
10% of Nominal Voltage at AC 5% of Nominal Voltage at DC
Design Specification/Test Requirements
Dielectric Withstand Voltage
Pole to Pole
(VRMS) 1000V
Contact to Coil
(VRMS) 5000V
Adjacent Contacts
(VRMS)
2500V
Input Voltage 12V AC/DC 24V AC/DC 48V DC 120V AC/DC 240V AC/DC
Impedance (Ohms)
Power Consumption ±10%
1 K 2 K 3 K 34 K 72 K
AC N/A 0.5V A N/A 0.4V A 0.8V A
DC 0.4 W 0.5 W 0.8 W 0.5 W 0.7 W
Mechanical
Degree of Protection IP20
Mechanical Life Operations 3 x 107
Electrical Life Operations
250V AC/24V DC, 8 A Resistive: 100 000 min.
24V DC, 10 A Resistive: 6000 min.
250V DC, 0.28 A Resistive: 6000 min.
250V AC, 10 A Resistive: 30 000 min.
Switching Frequency Operations (no-load) 1200 cycles/sec
Coil Voltages See Overview/Product Selection
Operating Time at Nominal Voltage at 20 °C (ms) Pickup typical 10 ms
Dropout typical 10 ms
Maximum Operating Rate (full load = 6 A) 6 cycles/min.
58 Rockwell Automation Publication 700-TD552F-EN-P - January 2021
Dimensions - 700-HL (2-pole)
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.
Environmental
Temperature Operating –40…+60 °C
Storage –40…+100 °C
Altitude 2000 m (6560 ft)
Construction
Insulating Material Molded High-Dielectric Material
Enclosure Relay RT II — flux-proof, pollution degree 2 installation environment
Contact Material AgNi 90/10 or AgNi 90/10 + Au
Terminal Markings on Socket In accordance with EN50 0005
Certifications cULus Listed (File No. E3125, Guide NRNT/NRNT7), CE Marked
Standards UL 508, CSA C22.2 No. 14, EN 61810-1
Cat. No. 700-HLT…2-Pole (Relay Output)
YRNX
HSNVUI
Bulletin 700-TBJ08_ 8-Way Jumper
Bulletin 700-HL Screw Terminal Design
Single Wire: 0.14 mm2…2.5 mm2 (#26 AWG…14 AWG)
Double Wire: 2 x 0.14 mm2…2 x 1.5 mm2 (2 x #26 AWG…2 x 16 AWG)
Wire Type: Solid or stranded, copper only
Strip Length: 9 mm (11/32 in). Torque: 0.5 N•m (4.4 lb•in)
Bulletin 700-HL Spring Terminal Design
Single Wire: 0.2 mm2…2.5 mm2 (#24 AWG…#14 AWG)
Wire Type: Solid or stranded, copper only
Strip Length: 9 mm (11/32 in)
QT
HPNUUI
WU
HRNYUI
YWNX
HSNXUI
XWNW
HSNTUI
QT
HPNUUI
WU
HRNYUI
UL1059 TERMINAL BLOCK
CERTIFIED FOR HIGH FAULT SHORT CIRCUIT CURRENT RATINGS
UL CATEGORY CODE XCFR2
UL FILE NUMBER E40735
Rockwell Automation introduces updated ratings for a number of Power Terminal Blocks.
These updated ratings include new short circuit current withstand ratings following updated guidelines described for UL1059 products.
The updated UL requirements permit terminal blocks to be tested with short circuit protection devices (fuses and circuit breakers).
When the terminal block, fuse or circuit breaker, and wires are applied together, the terminal block may be rated with a short circuit current rating (withstand).
This rating may be related to the application of specific fuse or circuit breaker selected and the wire size for an application.
SHORT CIRCUIT
CURRENT RATINGS
(SCCR)
Per the requirements of the 2005 National Electric Code (NEC) and UL508A (effective April 25, 2006), many electrical panels must be rated for their Short Circuit Withstand Rating. Analyzing the SCCR of individual components, and the associated branch and feeder overcurrent devices is a method of determining the SCCR of an electrical assembly.
UL Standard 508A permits a terminal block to have a 10,000 A withstand capability without any additional testing.
STANDARD PRODUCT
Rockwell Automation has tested a number of the 1492-PD Power Terminal blocks to determine their SCCR related to the new testing requirements. These are the standard Power Terminal Blocks that have been used in Industrial Control Panels.
The new ratings for these blocks permit their continued use in panels where the higher SCCR ratings are required.
TECHNICAL DATA
POWER TERMINAL BLOCKS
BULLETIN 1492-PD SCCR DATA FOR USE WITH
FUSES AND CIRCUIT BREAKERS
HIGH FAULT SCCR RATINGS
– UP TO 200,000 A
CERTIFIED TO UL REQUIREMENTS
– XCFR2
STANDARD PRODUCT
ALLEN BRADLEY 1492-PDM3141
For Use with Fuses UL Ratings as of December 2006
Terminal Block Description
Suitable
(1) SCCR (2)
Cat. No. Number Amp RMS Volts of Poles Rating Line Load Sym A Max wire/phase wire/phase
Copper wire
(connector material)
Line Load J T RK1 RK5 G CC
#2 - #14 #2 - #14 1 1 #2 - #6 #2 - #6 200 200 200 100 60 30 100,000 600
1 4 #2 - #6 #10 - #14 200 200 200 100 60 30 200,000 600
#2 - #6 #2 - #6 200 200 200 100 60 30 100,000 600
#2 - #6 #2 - #6 200 200 200 100 60 30 100,000 600
#2/0 - #6 #2/0 - #6 200 200 200 100 60 30 65,000 600
#2/0 - #6 #2/0 - #6 200 200 200 100 60 30 65,000 600
1492-PDM3111 3 115
---00100100101# - 8#01# - 8# 60 30 100,000 600
---00100100101# - 8#01# - 8# 60 30 100,000 600
---00100100101# - 8#01# - 8# 60 30 100,000 600
#2 - #14 #10- #18
1492-PDM3141 3 115
01# - 8# #14 100 100 100 30 60 30 100,000 600
#2 - #14 #2 - #14
#2 - #14 #2 - #14
1 1
1 1
1492-50Y Aluminum
1492-50X Aluminum
Aluminum
Aluminum kcmil/AWG
Conductors (3)Rated Wire Range
Copper wire
Fuse Required Class/Max Amp Rating
Overcurrent Protection (4)
3 115
Aluminum
1 1 1492-100Y
2/0 - #14 2/0 - #14 1 1
1 4
1492-100X Aluminum
Aluminum
Copper
2/0 - #14 #4 - #14
1 4 2/0 - #14 #4 - #14
1492-PD3141
1492-PD3C141
1 175
200 200 200 100 60 30 100,000 6002/0 - #6 #4 - #14
200 200 200 100 60 30 100,000 6002/0 - #6 #4 - #14
2/0 - #14 2/0 - #14
Terminal Block Description High SCCR Ratings Conditions (1) SCCR (2)
400 kcmil - #6 #2- #14
1 6
1492-PD3163
3 335Aluminum
#2 - #8 400 400 400 200 --- 30 200,000 600
400 kmil-3/0 #2 - #8 400 400 400 200 60 30 100,000 600
(2) 2/0 - #2 #4 - #8 400 400 400 100 60 30 100,000 600
(2) #4 - #6 #10 - #14 200 200 200 100 60 30 100,000 600
2/0 - #6 #2 - #14 200 200 200 100 60 30 100,000 600
--- --- --- --- 60 --- 100,000 600 200 200 200 100 --- 30 200,000 600
#2 - #8 600 --- --- --- 60 --- 100,000 600
400 kcmil - #6 #2- #14 1 8
1492-PD3183 3 335
2/0 - #14 #4 - #14 2 6
1492-PD3263
Aluminum
Aluminum
400 kmil-3/0
2/0 - #6 #2 - #14
1492-PD
High SCCR Ratings
(with fuses)
Per UL 1059
XCFR2.E40735
jpeterson Rectangle 1 4 #2 - #6 #10 - #14 200 200 200 100 60 30 200,000 600 #2 - #14 #10- #18
1492-PDM3141 3 115
#8 - # 10 #14 100 100 100 30 60 30 100,000 600 Aluminum jpeterson Line jpeterson Line jpeterson Line jpeterson Line jpeterson Line jpeterson Line jpeterson Line jpeterson Line jpeterson Line jpeterson Line jpeterson Line
1492-PD3C163
Aluminum
Copper
Copper
500 kcmil - #4 #2- #14
350 kcmil - #6 350 kcmil - #6
500 kcmil - #4 500 kcmil - #4
500 kcmil - #4 #2- #14
600 kcmil - #4 600 kcmil - #4
1492-PD31123
1 1
2 2
1492-BF
Aluminum
Aluminum
Aluminum
2 2
1492-PD3226
1492-PD3287
1492-BG
Aluminum
1 12 3 380
3 380
1 420
3 620
1 760
1 6
2/0 - #14 #4- #14
1492-PD3C63
2 6
3 350
500 kcmil - #6 #2- #14
2 8
3 760
(2) 4/0 - #4
Terminal Block Description
Suitable Cat. No. Number Amp of Poles Rating Line Load wire/phase wire/phase
Copper wire
(connector material) kcmil/AWG
Conductors (3)Rated Wire Range
Copper wire
Terminal Block Description High SCCR Ratings Conditions (1) SCCR (2)
1492-PD
High SCCR Ratings
(with fuses)
Per UL 1059
XCFR2.E40735
(2) 350 kcmil - #4
(2) 350 kcmil - #4
(2)500 kcmil-250 kcmil
(2)500 kcmil-250 kcmil
(2)500 kcmil-250 kcmil
(2)500 kcmil-250 kcmil
Copper
Copper
Aluminum
1492-PD3C287
500 kcmil - #6 #2- #14
2 8
3 760
(2) 4/0 - #4
1492-PD32127
500 kcmil - #6 #2- #14
2 12
3 760
(2) 4/0 - #4
1492-PD3C2127
500 kcmil - #6 #2- #14
2 12
2/0 - #10 400 400 400 200 60 30 100,000 600
500 kcmil - 3/0 #2 - #8 400 400 400 200 60 30 100,000 600
500 kcmil - 3/0 #2 - #8 400 400 400 200 60 30 100,000 600
2/0 - #4 #2 - #14 200 200 200 100 60 30 100,000 600
(2) 2/0 - #2 #4 - #8 400 400 400 100 60 30 100,000 600
(2) #4 - #6 #10 - #14 200 200 200 100 60 30 100,000 600
2/0 - #4 #2 - #14 200 200 200 100 60 30 100,000 600
600 kcmil - #2 600 kcmil - #2 600 600 - - - - 50,000 600
600 kcmil - #2 600 kcmil - #2 400 400 400 200 60 30 100,000 600
600 600 - - - - 50,000 600
400 400 400 200 60 30 100,000 600
600 600 600 200 60 30 100,000 600
(1) SCCR (2)
RMS Volts Sym A Max
Line Load J T RK1 RK5 G CC
Fuse Required Class/Max Amp Rating
Overcurrent Protection (4)
(2) 350 kcmil - #4
(2) 350 kcmil - #4
2/0 - #4 600 600 400 200 60 30 100,000 600
2/0 - #10 600 600 - - - - 50,000 600
2/0 - #4 600 600 400 200 60 30 100,000 600
2/0 - #6 600 600 - - - - 50,000 600
2/0 - #6 400 400 400 200 60 30 100,000 600
#4 - #8 600 600 600 - - - 50,000 600
#4 - #8 400 400 400 200 60 30 100,000 600
#4 - #14 600 600 - - - - 50,000 600
#4 - #14 400 400 400 200 60 30 100,000 600
#2 - #8 600 600 600 - - - 50,000 600
#2 - #8 400 400 400 200 60 30 100,000 600
#2 - #14 600 600 - - - - 50,000 600
#2 - #14 400 400 400 200 60 30 100,000 600
3 760
(2) 4/0 - #4
(1) Short-circuit Current Rating (SCCR) Conditions — Terminal blocks are considered suitable for use on a circuit capable of delivering not more than the stated SCCR at the maximum voltage speciÞed when protected by the max ampere and Class of overcurrent protective device noted in the individual Recognitions. Short-circuit current ratings may be marked on the terminal block or on instructions provided with the terminal block. Short-circuit current ratings have been determined based on the terminal block's use within the minimum enclosure sizes as speciÞed in Condition of Acceptability.
(2) Short-circuit Current Rating, when noted additional conditions are provided. When larger overcurrent protection device of type or wire of di!erent size is used, the Power Terminal block has a 10,000 amp withstand rating. Note: The rated wire range of terminals may exceed the restrictive wire range used to provide higher SCCR.
(3) Size Range of Line and Load conductors suitable to maintain noted SCCR
(4) Maximum Size of Line side overcurrent protection to provide noted SCCR jpeterson Line
Publication 1492-TD013B-EN-P – December 2006 Copyright ©2006 Rockwell Automation, Inc. All Rights Reserved. Printed in USA.
For Use with Circuit Breakers
RMS Volts
(1) Short-circuit Current Rating (SCCR) Conditions — Terminal blocks are considered suitable for use on a circuit capable of delivering not more than the stated SCCR at the maximum voltage speciÞed when protected by the max ampere and Class of overcurrent protective device noted in the individual Recognitions. Short-circuit current ratings may be marked on the terminal block or on instructions provided with the terminal block. Short-circuit current ratings have been determined based on the terminal block's use within the minimum enclosure sizes as speciÞed in Condition of Acceptability.
(2) Short-circuit Current Rating, when noted additional conditions are provided. When larger overcurrent protection device of type or wire of di!erent size is used, the Power Terminal block has a 10,000 amp withstand rating. Note: The rated wire range of terminals may exceed the restrictive wire range used to provide higher SCCR.
(3) Size Range of Line and Load conductors suitable to maintain noted SCCR
(4) Maximum Size of Line side overcurrent protection to provide noted SCCR
(5) Catalog number is incomplete. Example: 140U-H2C3-xnn Refer to Bulletin 140U documentation for complete catalog number.
Aluminum
Aluminum
1492-PD3141
1492-PD3163
2/0 - #14 #4- #14
1 4 3 175
400 - #6 #4- #14 1 6
3 335
Terminal Block Description
Suitable
High SCCR Ratings Conditions (1) SCCR (2)
Cat. No. Number Amp of Poles Rating Line Load Sym A Max wire/phase wire/phase (connector material)
#2-#14 #10- #18 1 4
#2 - #10 #10 - #14 125 125 --- --- --- --- 25,000 480
2/0 - #1 #4 - #10 --- --- 250 250 --- --- 22,000 480
#2 - #4 #4 - #12 --- --- 250 250 --- --- 22,000 480
#2 - #6 #4 - #14 125 --- --- --- --- --- 30,000 480
#2 - #6 #4 - #14 --- 125 --- --- --- --- 50,000 480
400 - 3/0 #2 - #8 --- --- --- --- --- 400 65,000 480
400 - 3/0 #2 - #8 --- --- --- --- 400 --- 25,000 480
4/0 - #4 #2 - #12 --- --- 250 250 --- --- 25,000 480
1492-PDM3141 3 115
Aluminum kcmil/AWG
Conductors (3)Rated Wire Range
Copper wire
Line Load H3C3 H6C3 J3X3 J6X3 K3X3 K6X3
(1) SCCR (2)
Terminal Block Description High SCCR Ratings Conditions (1) SCCR (2)
Maximum Ampacity of Circuit Breaker Allen-Bradley Circuit Breaker
Bulletin 140U-
Overcurrent Protection (4)
(5)
1492-PD
High SCCR Ratings
(with circuit breakers) jpeterson Line
10 Rockwell Automation Publication 800-TD009G-EN-P - February 2021
Push Button Devices
Momentary Contact Devices — Illuminated
800 – B H G 2 QR H
a b c d e f g h a b c d
Protection Rating Fingersafe Guards Power Module Type Head Type
Code Description Code Description 800T Code
Description 800H Code
Code Description
T Metal, Type 4/13 Blank No guards A Extended head with guard
H Plastic, Type 4/4X/13 C Guard on terminals P Transformer (or dual input) PR B Extended head without guard
Q Full voltage QR M Mushroom (1)
(1) Mushroom and jumbo mushroom head not available in yellow.
S Operator only (2)
(2) Operator only supplied without power module, lamp, lens cap, or contact blocks.
— MJ Jumbo mushroom (1) e f g h
Illumination Options Voltage Lens Color Contact Blocks
Code Description Code Description Code Description Code Description
Blank Incandescent Transformer Blank
No lens with standard contacts 1 N.O. - 1 N.C.
X No contacts
H LED 16 120V AC, 50/60 Hz Standard
Dual Input 26 240V AC, 50/60 Hz X
No lens if any contacts other than standard 1 N.O. - 1 N.C is ordered.
Blank 1 N.O. - 1 N.C.
D Diode type (1)
(1) Diode type dual input provides circuit isolation via opposing diodes. Not recommended for use with solid-state outputs.
46 480V AC, 50/60 Hz D1 1 N.O.
T Transformer — relay type (2)
(2) Dual input (transformer relay type) is not configurable with Class I Div. 2 contact blocks.
56 600V AC, 50/60 Hz A Amber PenTUFF (Low Voltage)
Full Voltage — Incandescent
B Blue AV 1 N.O. - 1 N.C.
TH
Transformer — relay type LED (2) C Clear Class I, Div. 2 – Explosion-protected
12 12V AC/DC G Green AF 1 N.O. - 1 N.C.
24 24V AC/DC R Red Class I, Div. 2 – Logic Reed
48 48V AC/DC W White AR 1 N.O. - 1 N.C.
10 120V AC/DC Y Yellow Class I, Div. 2 – Stackable Sealed Switch
20 240V AC/DC AY 1 N.O. - 1 N.C.
Full Voltage — LED
2 12…130V AC/DC
Dual Input
16 120V AC
24 24V AC/DC (3)
(3) Dual-input diode only.
Operator Only
00 No power module
Extended Head Without Guard
Cat. No. 800T-PB16R
Extended Head without Guard
Cat. No. 800H-PRB16R jpeterson Text Box
ALLEN-BRADLEY 800H-QRBH2G
jpeterson Rectangle T Metal, Type 4/13 H Plastic, Type 4/4X/13 jpeterson Line jpeterson Rectangle Transformer (or dual input) PR Full voltage QR Operator only (2) jpeterson Line jpeterson Rectangle A Extended head with guard B Extended head without guard M Mushroom (1) jpeterson Line jpeterson Rectangle e Illumination Options Code Description Blank Incandescent
H LED
Dual Input jpeterson Rectangle jpeterson Line jpeterson Line jpeterson Line jpeterson Line jpeterson Line jpeterson Line jpeterson Rectangle C Clear G Green R Red jpeterson Line jpeterson Line jpeterson Line jpeterson Line jpeterson Line
8 Rockwell Automation Publication 800-TD009G-EN-P - February 2021
Emergency Stop Devices (Trigger Action)
2-position — Illuminated
• Light-emitting diode (LED) illumination is provided as standard
800 QH 2 R A– TFRXJT H
a b c d e f a b c
Protection Rating…