Attachment_06_00_00_01_Specifications_6of9_LeadvilleWTP-B3_11-07-2023_1.pdf

PDF 33 MB Posted

Attached to
Leadville Water Treatment Plant
Solicitation number
140R6024R0009
Issued by

About this file

This document provides details for a federal contract opportunity to upgrade the Leadville Water Treatment Plant. The solicitation number is 140R6024R0009 and is being issued by the Department of the Interior Bureau of Reclamation for pre-solicitation purposes. The opportunity involves upgrading infrastructure at the Leadville Water Treatment Plant to improve water treatment services. Interested vendors should monitor the Federal Business Opportunities website for when the formal solicitation is issued to obtain the required specifications and submit a proposal by the response date. The award date will be determined once proposals have been evaluated.

View the file

Other files

File Type Posted
Attachment_17_00_00_02_InfoDwgs_5of6_LeadvilleWTP-B3_1111-1175_11x17_11-07-2023_1.pdf PDF
Attachment_19_00_00_02_StdDwgs_1of1_LeadvilleWTP-B3_1261-1307_11x17_11-07-2023_1.pdf PDF
Attachment_18_00_00_02_InfoDwgs_6of6_LeadvilleWTP-B3_1176-1260_11x17_11-07-2023_1.pdf PDF
Attachment_07_00_00_01_Specifications_7of9_LeadvilleWTP-B3_11-07-2023_1.pdf PDF
Attachment_14_00_00_02_InfoDwgs_2of6_LeadvilleWTP-B3_861-975_11x17_11-07-2023_1.pdf PDF
Attachment_08_00_00_01_Specifications_8of9_LeadvilleWTP-B3_11-07-2023_1.pdf PDF
Attachment_09_00_00_01_Specifications_9of9_LeadvilleWTP-B3_11-07-2023_1.pdf PDF
LWTP_Presolicitation_Notice_26Dec23_1.pdf PDF
Attachment_01_00_00_01_Specifications_1of9_LeadvilleWTP-B3_11-07-2023_1.pdf PDF
Attachment_02_00_00_01_Specifications_2of9_LeadvilleWTP-B3_11-07-2023_1.pdf PDF
Attachment_16_00_00_02_InfoDwgs_4of6_LeadvilleWTP-B3_1041-1110_11x17_11-07-2023_1.pdf PDF
Attachment_10_00_00_02_Drawings_1of3_LeadvilleWTP-B3_001-200_11x17_11-07-2023_1.pdf PDF
Attachment_15_00_00_02_InfoDwgs_3of6_LeadvilleWTP-B3_976-1040_11x17_11-07-2023_1.pdf PDF
Attachment_03_00_00_01_Specifications_3of9_LeadvilleWTP-B3_11-07-2023_1.pdf PDF
Attachment_12_00_00_02_Drawings_3of3_LeadvilleWTP-B3_401-678_11x17_11-07-2023_1.pdf PDF
Attachment_11_00_00_02_Drawings_2of3_LeadvilleWTP-B3_201-400_11x17_11-07-2023_1.pdf PDF
Attachment_04_00_00_01_Specifications_4of9_LeadvilleWTP-B3_11-07-2023_1.pdf PDF
Attachment_05_00_00_01_Specifications_5of9_LeadvilleWTP-B3_11-07-2023_1.pdf PDF
140R6024R0009_Draft_RFP_1.pdf PDF
Attachment_13_00_00_02_InfoDwgs_1of6_LeadvilleWTP-B3_679-860_11x17_11-07-2023_1.pdf PDF
Show all 20

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LEADVILLE MINE

PROJECT # C-3553-0122

MECHANICAL CUT SHEETS - TABLE OF CONTENTS

SECTION PAGE

Aquamatic Eductor 3

Snyder Tanks 5

Bray High Vis Indicators 6

Bray Proximity Sensors 8

Endress + Hauser pH Sensor 10

Hach Turbidimeter Transmitter 74

IFM Pressure Sensors 80

IFM Temperature Sensor 85

Rosemount Flow meter 89

Inge Composite Coupling 143

Inge Membranes 145

Inge T-Rack 3.0 147

Labcock Valves 221

ASCO Solenoid Valves 222

Bray Butterfly Valves 241

Flow-Tek Ball valves_____ 271

Griffco Pressure Relief Valves 273

Numatics filter/regulator 279

Hayward Check Valves 281

Tek-Bar Press Transmitters ______________________________________________ 291

Tekleen Strainer________________________________________________________325

Bray Series 92 Actuators_________________________________________________355

Festo Silencers ________________________________________________________ 365

Inge Fiber Repair Kit____________________________________________________386

CIP Batch Tank/Mixer___________________________________________________408

PVC Pipe/Fittings 463

Wika Pressure Guages___________________________________________________ 465

Chromalox Heater 469

Goulds Feed Pump 474

Goulds CIP Pump 478

AquaMatic® Fluid Ejectors 540 Series

COMMERCIAL

CONTROL VALVE

ACCESSORIES

NPT

A B

C

A

D

DIA

Socket Weld

AquaMatic 540 Series Fluid Ejectors are constructed of corrosion-resistant PVC and specifically designed for water treatment applications. The ejector cartridge is chemically bonded inside the housing for years of trouble-free service. For optimum performance, ejectors should be installed with a section of the straight pipe extending from the discharge area.

Size – Inches A B C D E Series

NPT Slip Diameter – Inches (mm) which are supplied by vendor, all dimensions are subject to variations.

A B

C

A

D

DIA

E TYP (3)

Dimensions

TAG NUMBER: EDR-3026

COMMERCIAL

CONTROL VALVE

ACESSORIES

AquaMatic® Fluid Ejectors 540 Series

Inlet

Pres-sure

P.S.I.

(Bars)

Nozzle Flow Rates – gals/min (L/min)

540 1/2-inch 541 3/4-inch 542 1-inch 544 1-1/2-inch 546 2-inch

540-1 540-2 540-3 540-4 540-5 Draw 541-1 541-2 541-3 Draw 542-1 542-2 542-3 Draw 544-1 544-2 544-3 544-4 544-5 Draw 546-1 546-2 546-3 546-4 546-5 Draw

Black Brown Red White Blue Factor Red White Blue Factor Red White Blue Factor Red White Blue Yellow Orange Factor Red White Blue Yellow Orange Factor

Throat

To Calculate Drawrate

Specific Gravity Chart

Fluid Specific Gravity

Cl

Example:

How to Order

Example:

0 2 4 6 8 10

E ffi c ie n c y

Backpressure (lbs./sq. in.)

Inlet Pressure lbs/sq in

Fig. 1: Efficiency vs. Backpressure

Fluid Specific Gravity

Fluid Specific Gravity

20580 Enterprise Avenue 5730 North Glen Park Road ©2009 Pentair Residential Filtration, LLC Brookfield, WI 53045 Milwaukee, WI 53209 3026818 Rev B DE09 Tel: 262.784.4490 Tel: 262.238.4400 Fax: 262.784.7794 Fax: 262.238.4402

Customer Care: 800.279.9404 www.pentairwatertreatment.com

Performance

TAG NUMBERS: TNK-3000, TNK-4000

Series 54 Activator High Visibility Adjustable

All information herein is proprietary, confidential, and may not be copied or reproduced without the expressed written consent of BRAY INTERNATIONAL, Inc.

The technical data herein is for general information only. Product suitability should be based solely upon customer’s detailed knowledge and experience with their application.

- 1 - Rev. 11_2017bray.com

ASSEMBLY

FEATURES

TECHNICAL DATA

Housing material PC Activator material PA Valve status indicator Red = Closed

Yellow = Open Indicator adjustments 5 degree increments Activator adjustment – top level 5 degree increments

Activator adjustment – bottom level 90 degree increments

Hardware 316 stainless steel Activator targets 303 stainless steel

ACTIVATOR AND MOUNTING KITS

30 x 80mm mounting pattern, adjustable activator

Description Hardware Kit part number

Bray S92/93 Sizes 63 to 128 Imperial 54063C-14800536

Bray S92/93 Sizes 63 to 128 and Series 98 NAMUR VDI/VDE 3845 Compliant mounting

Metric 54063C-14850536

Parts List

Qty Imperial - 54063C-14800536 Metric - 54063C-14850536

1 Activator assembly Activator assembly

See Series 54 IOM for full mounting details

Series 92/93 Actuator Series 98 Actuator

• High-visibility display

• Three level adjustable activator

• Protection against contamination and damage

• Suitable for CW and CCW operation

• 30 x 80mm actuator mounting

• 30 x 130mm actuator mounting

Series 54 Activator High Visibility Adjustable

All statements, technical information, and recommendations in this bulletin are for general use only. Consult Bray representatives or factory for the specific requirements and material selection for your intended application. The right to change or modify product design or product without prior notice is reserved.

Patents issued and applied for worldwide.

Bray® is a registered trademark of Bray International, Inc.

© 2017 Bray International. All rights reserved. TM-10751_EL_Series54-HVA_11_2017

HEADQUARTERS

Bray International, Inc.

13333 Westland East Blvd.

Houston, Texas 77041 Tel: 281.894.5454 bray.com

30 x 130mm mounting pattern, adjustable activator

Description Hardware Kit part number

Bray S92/93 Sizes 160 to 210 Imperial 54160C-14800536

Bray S92/93 Sizes 160 to 255 NAMUR VDI/VDE 3845 Compliant mounting

Metric 54160C-14850536

Qty. Imperial - 54160C-14800536 Metric - 54160C-14850536

1 Activator assembly Activator assembly

1 Mounting plate assembly Mounting plate assembly

See Series 54 IOM for full mounting details

Series 92/93 Actuator ø 5.

52 52 ø

.6

DIMENSIONS

540001-71104533Series 54 Inductive Proximity Sensor

All information herein is proprietary, confidential, and may not be copied or reproduced without the expressed written consent of BRAY INTERNATIONAL, Inc.

The technical data herein is for general information only. Product suitability should be based solely upon customer’s detailed knowledge and experience with their application.

- 1 - Rev. 11_2017bray.com

General specifications

Switching function 2 x normally open (NO)

Output type PNP, 3-wire

Rated operating distance sn 3 mm

Installation Flush mountable

Output polarity DC

Assured operating distance sa 0 ... 2.43 mm

Actual operating distance sr 2.7 ... 3.3 mm typ.

Nominal ratings

Operating voltage UB 10 ... 30 V DC

Switching frequency f 0 ... 500 Hz

Hysteresis H Typ 5 %

Reverse polarity protection All connections

Short-circuit protection Pulsing

Voltage drop Ud 3 V

Operating current IL 0 ... 100 mA

Off-state current Ir 0 ... 0.5 mA typ. 0.1 μA at 25 °C

No-load supply current IO 25 mA

Operating voltage indicator LED, green

Switching state indicator LED, yellow

Functional safety related parameters

MTTFd 780 a

Mission Time (TM) 20 a

Diagnostic Coverage (DC) 0%

Ambient conditions

Ambient temperature TA -25 ... 70 °C (-13 ... 158 °F)

Mechanical specifications

Connection (system side) 4-pin, M12 x 1 connector

Housing material PBT

Sensing face material PBT

Degree of protection IP67

Standard conformity

Standards

EN 60947-5-2:2007

IEC 60947-5-2:2007

Approvals and certificates

UL approval cULus listed, general purpose

M12 x 1

5.4

LED

II

I

33.5

DIMENSIONS

FEATURES

TECHNICAL DATA

• DC 3-wire PNP sensor

• IP 67 rugged plastic housing

• Hermetically sealed

• Vibration, shock and corrosion resistant

• Compact design

• High visibility LED for power and switch status

ACTIVATORS

Activators sold separatelyvators sold separately

540001-71104533Series 54 Inductive Proximity Sensor

All statements, technical information, and recommendations in this bulletin are for general use only. Consult Bray representatives or factory for the specific requirements and material selection for your intended application. The right to change or modify product design or product without prior notice is reserved.

Patents issued and applied for worldwide.

Bray® is a registered trademark of Bray International, Inc.

© 2017 Bray International. All rights reserved. TM-1065_EL_Series54-0001_11_2017

HEADQUARTERS

Bray International, Inc.

13333 Westland East Blvd.

Houston, Texas 77041 Tel: 281.894.5454 bray.com

ACTIVATOR AND MOUNTING KITS

WIRING DIAGRAM CONNECTOR PINOUT

ACCESSORIES

30 x 80 mm NAMUR Mounting, adjustable

54063A-14800536 Fits Bray S92/93 Sizes 63 to 128 - Imperial

54063A-14850536 Fits Bray S92/93 Sizes 63 to 128 and Series 98 - Metric

30 x 130 mm NAMUR Mounting, adjustable

54160A-14800536 Fits Bray S92/93 Sizes 160 to 210 - Imperial

54160A-14850536 Fits Bray S92/93 Sizes 160 to 255 - Metric

30 x 80 mm NAMUR Mounting, adjustable, High Visibility

54063C-14800536 Fits Bray S92/93 Sizes 63 to 128 - Imperial

54063C-14850536 Fits Bray S92/93 Sizes 63 to 128 and Series 98 - Metric

30 x 130 mm NAMUR Mounting, adjustable, High Visibility

54160C-14800536 Fits Bray S92/93 Sizes 160 to 210 - Imperial

54160C-14850536 Fits Bray S92/93 Sizes 160 to 255 - Metric

I

I

I L+

L-II

II

090005-76145882 Sensor Cordset - M12 female straight connector to flying leads, 4-pin, 5 meters, zinc

090004-76145534 Sensor Cordset - M12 female straight connector to flying leads, 4-pin, 5 meters, stainless steel

600250-23663536 Y-Connector Cordset (S62, S63) - M12 male straight connector, 5-pin (system side) to M12 female straight connector, 4-pin (sensor side) AND Type I valve connector (DIN 43650)

600250-23666536 Y-Connector Cordset (S60) - M12 male straight connector, 5-pin (system side) to M12 female straight connector, 4-pin (sensor side) AND Form A valve connector (DIN 43650)

630250-21524536 Series 63 - Valve Solenoid, NAMUR mount 3/2 or 5/2, Form B connector (DIN 43560), IP65, single 24vdc coil

621250-21524536 Series 62 - Valve Solenoid, NAMUR mount 3/2 or 5/2, Form B connector (DIN 43560), IP65, single 24vdc coil

TAG NUMBER: AIT-3022

TAG NUMBER: AE-3022

Outlet 1

MENU

CH 1:1 pH

CH 1:1 Temperature

CH 1:2

CH 2:1 Cond I

CH 2:2 Chlorine

CH 3:1 Current Input [Flow]

Cond I

6.99 pH

25.1 °C

9.02 mS/cm

13.41 mS/cm

9.03 mg/l

15.1 nA

11:12:13 29.06.2013

10.00 mS/cm

8.00 mS/cm

29.05.2013 10:02:20

29.06.2013 11:09:15

6.00 pH

29.05.2013 10:02:20

29.06.2013 11:09:15

12.00 pH

Field Data Manager

1 4

Slots

Ports

BASE-E 2DS 2DS 2DS 2AI 2AO 4R

1 2

S e n s o r

S e n s o r

S e n s o r

S e n s o r

S e n s o r

S e n s o r

1 2 3 4

R e la y

R e la y

R e la y

R e la y

Slot

Slot 4 Port 1 Pin 41 mA optional

L+

L-

L

N

HART

mA optional mA mA optional optional optional optional optional

PE

mA mA optional mA optional optional mA mA optional optional optional optional optional

3 8

3 8 mA mA optional mA mA optional

HART

mA optional mA mA

– optional

L+

L-

L

N

PE

optional mA mA optional optional optional optional

3 8 mA mA optional mA mA optional mA optional

HART

mA optional optional

L+

L-

L

N

PE

MEMO SENS

1 2 3

1 2 3

N

L

P E

SD

D is p la y

S e n s o r s u p p ly

S e rv ic e

PK

GY

PK

GYGY

L

N

P o w e r

L / +

N / –

PE

1 2

S e n s o r

BN

WH

GN

YE

BN

WH

GN

YE

A

B

A

B

A la rm

32 0 /4 m A

H A

R T

L N

+ RD

- BK

L/+ N/– *

Power

SD

D is p la y 1 2

S e n s o r

/4 m A

S e n s o r s u p p ly

S e rv ic e

PK

GY

PK

GY

L/+ N/– PE

BN

WH

GN

YE

BN

WH

GN

YE

A

B

A

B

A la rm

H A

R

TP

o w e r

(i n te rn a l)

B

/4 m

A

R e la y

R e la y

R e la y

R e la y

R e la y

R e la y

R e la y

R e la y

S e n s o r s u p p ly

PK

GY

PK

GYGY

BN

WH

GN

YE

A

B

BN

WH

GN

YE

A

B

S e n s o r

S e n s o r

/4 m A

/4 m A

/4 m A

24 0 /4 m A

E th e rn e t

A

D P

/R S

5B

C

DGND

VP

D

IP

s w it c h o n

128/SW

ServiceT C

O M

S F

B F

P W

R

A'

B'

C'

R J

E th e rn e t

D

IP

s w it c h o n

128/SW

Service

C O

M S

F B

F P

W R

R J

BN

WH

GN

YE

Sensor

PK

GY

GN

YE

Sensor

2DS

Sensor 1

Sensor 2

PK

GY

GN

YE

BN

WH

GN

YE

Sensor

Sensor m in

.9 min. 20 (0.79) min. 50 (1.97) min. 20 (0.79) m in

.9

4 x min. Ø 8 (0.31) min. Ø 15 (0.59)

.5

.1

105 (4.13)

140 (5.51) a b b

99 (3.90)

97 (3.82)

.5

.3

.9

TS 35

.4

.5

.5

TS 35

.9

83 (3.27)

220 (8.66)

97 (3.82)

.5

.3

.9

.9

205.5 (8.09)

.4

TS 35

TS 35

.5

.5

.6

144 (5.67)

.5

.5

.1

125 (4.92)

.7

32 (1.26) 40 (1.58) 99 (3.99)

.5 out in

.9

45 (1.77) 100 (3.94) 32 (1.26) 102 (4.02)

.8

A A

B

B-B

A-A

193 (7.60)

123 (4.84)

.1

.6

R16

13.5 (0.53)

36 (1.42)

.6

40 (1.57)

47 (1.85)

144.5 (5.69)

Outlet 1

MENU

CH 1:1 pH

CH 1:1 Temperature

CH 1:2 Nitrate

CH 2:1 SAC

CH 2:2 Turbidity

CH 3:1 Current Input [Flow]

6.99 pH

25.1 °C

9.02 mg/l

2.02 1/m

1022 FNU

15.1 nA

11:09:15 29.01.2013

2 3

FXA291

Master class 1

(PLC, DCS)

T T

Ethernet

PROFIBUS DP

(RS485)

Master class 2 (FieldCare, PDM)

FieldCare / Webbrowser

FXA291

Modbus Master / Gateway

T T

Ethernet

Modbus RS485

(RTU, ASCII)

FieldCare / Webbrowser

CPS11D-7BA21

15° 15°

A

A C

18 B

50 100 200 250

[psi] p [bar]

T [°F] 400 20 60 80 100

T [°C]

120 135-15

D

(0.47)

(4

.7

.8

.1

.9

(0.47)

(4

.7

.8

.1

.9

(4

.7

.8

.1

.7

12 / 0.47

(4

.7

.8

.1

.7

12 / 0.47

TAG NUMBER: AIT-1046

TAG NUMBERS: FE-1044, AE-1045

Pressure sensors

1: 4-digit alphanumeric display 2: LEDs (display unit / switching status) 3: Programming button

PN2224

Combined pressure sensor

PN22

Quick disconnect Process connection ¼'' NPT

Zero and span adjustable Function programmable

2 outputs OUT1 = switching output

OUT2 = switching output or analog output

4-digit alphanumeric display

Measuring range

-14.5...145.0 PSI

-1...10 bar

-100...1000 kPa

Type of pressure: relative pressure Liquids and gases

Application

DC PNP/NPNElectrical design 2 x normally open / closed programmable or 1 x normally open / closed programmable + 1 x analog (4...20 mA / 0...10 V; programmable 1:4)

Output

20...30 DC ¹)Operating voltage [V] 2 x 250Current rating [mA]

Yes (non-latching)Short-circuit protection yesReverse polarity protection yesOverload protection yesIntegrated watchdog < 2Voltage drop [V] < 65Current consumption [mA]

4...20 mA / 0...10 VAnalog output 4...20 mA: max. (Ub - 10 V) x 50 / 0...10 V: min. 2000Load for analog output [ohms]

7500 kPa75 bar1088 PSIPressure rating 15000 kPa150 bar2175 PSIBursting pressure min.

Setting range -88...1000 kPa-0.88...10.00 bar-12.8...145.0 PSISet point, SP -94...994 kPa-0.94...9.94 bar-13.6...144.2 PSIReset point, rP -100...340 kPa-1.00...3.40 bar-14.6...49.4 PSIAnalog start point, ASP 176...1000 kPa1.76...10.00 bar25.4...145.0 PSIAnalog end point, AEP

2 kPa0.02 bar0.2 PSIin steps of hysteresis / window function; N.O. / N.C; output polarity; current / voltage outputs;

damping; calibration of displayed values; display can be rotated / deactivated; display unit

Programming options

Accuracy / deviations (in % of the span) Turn down 1:1

< ± 0.5Switch point accuracy < ± 0.25 (BFSL) / < ± 0.5 (LS)Characteristics deviation *)

< ± 0.5Linearity < ± 0.1Hysteresis < ± 0.1Repeatability **)

TAG NUMBER: PIT-0110

< ± 0.1Long-term stability ***) Temperature coefficients (TEMPCO) in the temperature range -25...80° C (in % of the span per 10 K)

< ± 0.1Greatest TEMPCO of the zero point < ± 0.2Greatest TEMPCO of the span ifm efector, inc. 782 Springdale Drive, Exton, PA 19341 — We reserve the right to make technical alterations without prior notice. — US — PN2224 — 30.07.2009

PN2224

0.2Power-on delay time [s]

Min. response time switching outputs [ms]

0; 10; 20;...100; 200;...4000 Damping for the switching output (dAP) [ms]

≤ 160Switching frequency [Hz] 3Response time analog output [ms]

0; 100; 500; 2000 Damping for the analog output (dAA) [ms]

-25...80Ambient temperature [°C] -25...80Medium temperature [°C] -40...100Storage temperature [°C] IP 65, IIIProtection

> 100 (500 V DC)Insulation resistance [MΩ] 50 g (11 ms)DIN IEC 68-2-27:Shock resistance 20 g (10...2000 Hz)DIN IEC 68-2-6:Vibration resistance

100 millionSwitching cycles min.

4 kV CD / 8 kV ADEN 61000-4-2 ESD:

10 V/mEN 61000-4-3 HF radiated:

2 kVEN 61000-4-4 Burst:

0.5/1 kVEN 61000-4-5 Surge:

10 VEN 61000-4-6 HF conducted:

EMC

stainless steel (304S15); stainless steel 316L / 1.4404; PC (Makrolon); PBT (Pocan);

PEI; FPM (Viton); EPDM/X (Santoprene); PTFE

Housing materials stainless steel (303S22); ceramics; FPM (Viton)Materials (wetted parts) 3 x LED greenDisplay unit 2 x LED yellowSwitching status 4-digit alphanumeric displayFunction display 4-digit alphanumeric displayMeasured values

Display

M12 connector; gold-plated contactsConnection

¹) to EN50178, SELV, PELV;

referring to UL: “limited voltage” with overcurrent protection in accordance with UL508 *) BFSL = Best Fit Straight Line / LS = Limit Value Setting **) with temperature fluctuations < 10 K ***) in % of the span per year

Remarks

Wiring

Programming of the output function

(OUT1 / OUT2):

Hno = hysteresis / normally open Hnc = hysteresis / normally closed Fno = window function / normally open Fnc = window function / normally closed Complementary outputs:

output 1: = Hno, output 2: = Hnc (with the same SP / rP)

Programming of the analog output (OUT2):

I = current output (4...20 mA) U = voltage output (0...10 V) ifm efector, inc. 782 Springdale Drive, Exton, PA 19341 — We reserve the right to make technical alterations without prior notice. — US — PN2224 — 30.07.2009

PN2224

Pressure sensors

1: 4-digit alphanumeric display 2: LEDs (display unit / switching status) 3: Programming button

PN2227

Combined pressure sensor

PN22

Quick disconnect Process connection ¼'' NPT

Display units:

mbar, kPa, PSI, inH2O Zero and span adjustable Function programmable

2 outputs OUT1 = switching output

OUT2 = switching output or analog output

4-digit alphanumeric display

Measuring range

-0.74...14.50 PSI

Type of pressure: relative pressure Liquids and gases

Application

DC PNP/NPNElectrical design 2 x normally open / closed programmable or 1 x normally open / closed programmable + 1 x analog (4...20 mA / 0...10 V; programmable 1:4)

Output

20...30 DC ¹)Operating voltage [V] 2 x 250Current rating [mA]

Yes (non-latching)Short-circuit protection yesReverse polarity protection yesOverload protection yesIntegrated watchdog < 2Voltage drop [V] < 65Current consumption [mA]

4...20 mA / 0...10 VAnalog output 4...20 mA: max. (Ub - 10 V) x 50 / 0...10 V: min. 2000Load for analog output [ohms]

145Pressure rating [PSI] 450Bursting pressure min. [PSI]

Setting range -0.68...14.50Set point, SP [PSI] -0.74...14.44Reset point, rP [PSI] -0.74...5.80Analog start point, ASP [PSI] 2.90...14.50Analog end point, AEP [PSI]

0.02in steps of [PSI] hysteresis / window function; N.O. / N.C; output polarity; current / voltage outputs;

damping; calibration of displayed values; display can be rotated / deactivated; display unit

Programming options

Accuracy / deviations (in % of the span) Turn down 1:1

< ± 0.5Switch point accuracy < ± 0.25 (BFSL) / < ± 0.5 (LS)Characteristics deviation *)

< ± 0.5Linearity < ± 0.1Hysteresis < ± 0.1Repeatability **)

< ± 0.1Long-term stability ***) Temperature coefficients (TEMPCO) in the temperature range 0...80° C (in % of the span per 10 K)

< ± 0.1Greatest TEMPCO of the zero point < ± 0.2Greatest TEMPCO of the span ifm efector, inc. 782 Springdale Drive, Exton, PA 19341 — We reserve the right to make technical alterations without prior notice. — US — PN2227 — 15.08.2005

PN2227

0.2Power-on delay time [s]

Min. response time switching outputs [ms]

0; 10; 20;...100; 200;...4000 Damping for the switching output (dAP) [ms]

≤ 170Switching frequency [Hz] 3Response time analog output [ms]

0; 100; 500; 2000 Damping for the analog output (dAA) [ms]

-25...80Ambient temperature [°C] -25...80Medium temperature [°C] -40...100Storage temperature [°C] IP 65, IIIProtection

> 100 (500 V DC)Insulation resistance [MΩ] 50 g (11 ms)DIN IEC 68-2-27:Shock resistance 20 g (10...2000 Hz)DIN IEC 68-2-6:Vibration resistance

100 millionSwitching cycles min.

4 kV CD / 8 kV ADEN 61000-4-2 ESD:

10 V/mEN 61000-4-3 HF radiated:

2 kVEN 61000-4-4 Burst:

0.5/1 kVEN 61000-4-5 Surge:

10 VEN 61000-4-6 HF conducted:

EMC

stainless steel (304S15); stainless steel 316L / 1.4404; PC (Makrolon); PBT (Pocan);

PEI; FPM (Viton); EPDM/X (Santoprene); PTFE

Housing materials stainless steel (303S22); ceramics; FPM (Viton)Materials (wetted parts) 4 x LED greenDisplay unit 2 x LED yellowSwitching status 4-digit alphanumeric displayFunction display 4-digit alphanumeric displayMeasured values

Display

M12 connector; gold-plated contactsConnection

¹) to EN50178, SELV, PELV;

referring to UL: “limited voltage” with overcurrent protection in accordance with UL508 *) BFSL = Best Fit Straight Line / LS = Limit Value Setting **) with temperature fluctuations < 10 K ***) in % of the span per year

Remarks

Wiring

Programming of the output function

(OUT1 / OUT2):

Hno = hysteresis / normally open Hnc = hysteresis / normally closed Fno = window function / normally open Fnc = window function / normally closed Complementary outputs:

output 1: = Hno, output 2: = Hnc (with the same SP / rP)

Programming of the analog output (OUT2):

I = current output (4...20 mA) U = voltage output (0...10 V) ifm efector, inc. 782 Springdale Drive, Exton, PA 19341 — We reserve the right to make technical alterations without prior notice. — US — PN2227 — 15.08.2005

PN2227

1: LEDs (display unit / switching status) 2: 4-digit alphanumeric display / alternating indication of red and green 3: Programming buttons 4: Upper part of the housing can be rotated by 345°

Product characteristics Electronic temperature sensor

Compact type for adapter

Quick disconnect

Process connection: internal thread M18 x 1.5 for adapter

Installation length EL: 45 mm

Switching output, analog output 4...20 mA or 0...10 V

4-digit alphanumeric display

Measuring range: -50...150 °C / -58...302 °F

Measuring element: 1 x Pt 1000, to DIN EN 60751, class A

Factory setting: -40...150 °C / -40...302 °F

Application liquids and gasesApplication

300Pressure rating [bar]

12Minimum installation depth [mm]

Electrical data DC PNP/NPNElectrical design

18...32 DC; cULus - Class 2 source requiredOperating voltage [V]

< 50Current consumption [mA]

IIIProtection class yesReverse polarity protection

Outputs Switching output, analog output 4...20 mA or 0...10 VOutput

1 x normally open / closed programmable + 1 x analog (4...20 mA / 0...10 V, scalable)Output function

250Current rating [mA]

< 2.5Voltage drop [V] yes (non-latching)Short-circuit protection

TN2511

Temperature sensorsTN-045KCBD18-MFPKG/US/

TAG NUMBER:

TE/TIT-0100

yesOverload protection

4...20 mA / 0...10 VAnalog output

4...20 mA: 500Max. load [Ω]

0...10 V: 2000Min. load [Ω]

Measuring / setting range -58...302 °F-50...150 °CMeasuring range

-40...150 °C / -40...302 °FFactory setting

Setting range

-57.6...302 °F-49.8...150 °CSet point, SP

-58...301.6 °F-50...149.8 °CReset point, rP

-58...293 °F-50...145 °CAnalog start point, ASP

-49...302 °F-45...150 °CAnalog end point, AEP

0.1 °F0.1 °Cin steps of

Resolution

0.1Switching output [K]

MS / 4096 *) | MS / 3561 **)Analog output [K]

0.1Display [K]

Accuracy / deviations ± 0.3 + (± 0.1 % MS)Switch point accuracy [K]

± 0.3 + (± 0.1 % MS)Analog output [K]

± 0.3 + (± 0.1 % MS)Display [K]

0.1 % MSTemperature drift ( / 10 K)

Reaction times 1Power-on delay time [s]

1 / 3 ***)Dynamic response T05 / T09 [s] yesIntegrated watchdog

Software / programming hysteresis / window function; NO / NC; output polarity; on delay, off delay; damping;

display unit Programming options

Interfaces IO-Link Device

COM2 (38.4 kBaud)Transfer type

1.1IO-Link revision

Environment -25...80Ambient temperature [°C]

-40...100Storage temperature [°C]

IP 67Protection

Tests / approvals

EMC DIN EN 61000-6-2

DIN EN 61000-6-3

Shock resistance 50 g (11 ms)DIN IEC 68-2-27:

Vibration resistance 20 g (10...2000 Hz)DIN EN 60068-2-6

470MTTF [Years]

K013UL approval number

Mechanical data

TN2511

Temperature sensorsTN-045KCBD18-MFPKG/US/ internal thread M18 x 1.5 for adapterProcess connection stainless steel (316L / 1.4404); O-ring: FKM 8 x 1.5 gr 80° Shore AMaterials (wetted parts)

45Probe length L [mm]

45Installation length EL [mm] stainless steel (316L / 1.4404); PBT+PC-GF 30; PBT-GF 20; PCHousing materials

0.206Weight [kg]

Displays / operating elements Display 2 x LED greenDisplay unit

LED yellowSwitching status 4-digit alphanumeric display / alternating indication of red and greenMeasured values

Electrical connection M12 connector; gold-plated contactsConnection

Wiring Core colors blackBK brownBN blueBU whiteWH

OUT1: switching output or IO-Link OUT2: Analog output Colours to DIN EN 60947-5-2

Remarks Remarks *) current output

**) voltage output ***) according to DIN EN 60751 MS = set measuring span The values for accuracy apply to flowing water.

cULus - Class 2 source required

1Pack quantity [piece] ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — US — TN2511 — 20.10.2015

TN2511

Temperature sensorsTN-045KCBD18-MFPKG/US/

Product characteristics Thermowell for temperature sensors

½" NPT

Environment 16Pressure rating [bar]

Mechanical data ½" NPTProcess connection

27Probe length L [mm]

8.4Inside diameter [mm] for types TNDesign stainless steel (316)Housing materials

Accessories Accessories (optional) heat conductive paste;

order no. 700692

Remarks 1Pack quantity [piece] ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — US — UT0028 — 18.11.2011

UT0028

Accessories

Product Data Sheet March 2016

00813-0300-4750, Rev BA

Best in class value with performance, reliability, and diagnostics suited for monitoring applications

Reliable all welded coil housing and lightweight sensor design rated to IP68

Process Diagnostics and SMART™ Meter Verification to provide better insight to the process and meter's health

Available with drinking water certifications

Rosemount™ 8750W Magnetic Flowmeter System for Utility, Water, and Wastewater Applications

TAG NUMBERS: FE-1044

Rosemount 8750W Flowmeter System March 2016

EmersonProcess.com/Rosemount

Product selection guide

The Rosemount 8750W Magnetic Flowmeter sensor is available in a flanged style and transmitter is available in remote and integral transmitter configurations to ensure compatibility with all utility, water, and wastewater applications.

For transmitter details, see Table 1 and Table 11.

For sensor styles and details, see Table 2 and Table 12.

For available lining materials, see Table 12.

For available electrode materials and electrode types, see Table 14.

For process reference (grounding) options, see Table 15 and Table 16.

For guidance on selecting materials, refer to the Magnetic Flowmeter Material Selection Guide located on Rosemount.com (document number 00816-0100-3033). For more information regarding the available product offering see the ordering information, Table 7 through Table 14.

Table 1. Transmitter Selections

Contents

Magmeter Diagnostics

Magnetic Flowmeter Sizing

Ordering Information

Specifications

Rosemount 8750W Field Mount Transmitter Specifications

Rosemount 8750W Wall Mount Transmitter Specifications

Rosemount 8750W Sensor Specifications

Product Certifications

Dimensional Drawings

Transmitter General characteristics

Field mount • Integral and remote mount configurations available

• HART®/analog and pulse outputs available

• Advanced Diagnostics available

• Optical switch local operator interface (optional)

• Two discrete channels (optional)

Wall mount • Remote mount configuration

• HART/analog and pulse outputs available

• Advanced Diagnostics available

• Easy to use local operator interface with dedicated configuration buttons (optional)

Table 2. Sensor Selection

Sensor General characteristics

Flanged • Flanged process connections

• Welded coil housing

• 1/2-in. (15 mm) to 48-in. (1200 mm)

• Standard, reference, and bullet-nose electrodes available

Rosemount 8750W Flowmeter SystemMarch 2016

EmersonProcess.com/Rosemount

Magmeter Diagnostics

Rosemount diagnostics reduce cost and improve output by enabling new practices

Rosemount Magnetic Flowmeters provide device diagnostics that detect and warn of abnormal situations throughout the life of the meter - from installation to maintenance and meter verification. With Rosemount Magnetic Flowmeter Diagnostics enabled, plant availability and throughput can be improved, and costs through simplified installation, maintenance and troubleshooting can be reduced.

Options for accessing diagnostics

Rosemount Magmeter Diagnostics can be accessed through the Local Operator Interface (LOI), a Field Communicator, AMS™ Suite: Intelligent Device Manager, and ProLink™. Contact your local Emerson™ Process Management representative to activate diagnostics or for diagnostic availability on existing transmitters.

Access diagnostics through the LOI for quicker installation, maintenance, and meter verification

Rosemount Magnetic Flowmeter Diagnostics are available through the LOI to simplify maintenance.

Access diagnostics through ProLink III(1)

Simplify maintenance and troubleshooting practices by utilizing ProLink III to access diagnostics and troubleshooting information, log variable data, run SMART Meter Verification, and print verification reports.

Access diagnostics through AMS Intelligent Device Manager for the ultimate value

The value of the diagnostics increases significantly when AMS Intelligent Device Manager is used. AMS Intelligent Device Manager provides a simplified screen flow and procedures for how to respond to the diagnostic messages.

Table 3. Magnetic Flowmeter Diagnostics

Diagnostic name Diagnostic category Product capability

Basic diagnostics

Tunable empty pipe Process Standard

Electronics temperature Maintenance Standard

Coil fault Maintenance Standard

Transmitter fault Maintenance Standard

Reverse flow Process Standard

Coil current(1) Maintenance Standard

Electrode saturation(1) Process/Maintenance Standard

Advanced diagnostics

High process noise Process Suite 1 (DA1)

Grounding and wiring fault Installation Suite 1 (DA1)

Coated electrode detection(1)

1. Only available with field mount transmitter.

Process Suite 1 (DA1)

Commanded SMART Meter Verification Meter Health Suite 2 (DA2)

Continuous SMART Meter Verification(1) Meter Health Suite 2 (DA2)

4–20 mA1 Loop Verification Installation Suite 2 (DA2)

1. Available with Prolink III v3.0 or later.

EmersonProcess.com/Rosemount

Magnetic Flowmeter Sizing

Selecting the appropriate sensor size is an important step when considering a magnetic flowmeter. The physical properties of the process fluid, as well as the fluid velocity should be considered. It may be necessary to select a flow sensor that is larger or smaller than the adjacent piping to ensure the fluid velocity is in the recommended flow range for the application.

Application guidelines and velocity ranges are provided in Table 4.

A table to convert from volumetric flow to velocity is shown in Table 5. Two examples of these calculations are show below.

Minimum and maximum flow rates based on line size are shown in Table 6.

Operation outside these guidelines may also give acceptable performance.

Table 4. Sizing Guidelines

To convert flow rate to velocity, use the appropriate factor listed in Table 5 and the following equation:

Example:

English units

Magmeter Size: 4-in. (factor from Table 5 = 39.679) Normal Flow Rate: 300 GPM

SI units

Magmeter Size: 100 mm (factor from Table 5 = 492.78) Normal Flow Rate: 800 L/min

Table 5. Line Size vs. Conversion Factor

Application Velocity range

(ft/s) Velocity range

(m/s)

Normal service 0–39 0–12

Preferred service 2–20 0.6–6.1

Velocity =

Velocity = 7.56 ft/s

300 (gpm) 39.679

Velocity =

Velocity = 1.62 m/s

800 (L/min) 492.78

Nominal line size Inches (mm)

Gallons per minute factor

Liters per minute factor

1/2 (15) 0.947 11.762

1 (25) 2.694 33.455

11/2 (40) 6.345 78.806

2 (50) 10.459 129.89

2 1/2 (65) 14.923 185.33

3 (80) 23.042 286.17

4 (100) 39.679 492.78

5 (125) 62.356 774.42

6 (150) 90.048 1,118.3

8 (200) 155.93 1,936.5

10 (250) 245.78 3,052.4

12 (300) 352.51 4,378.0

14 (350) 421.70 5,237.3

16 (400) 550.80 6,840.6

18 (450) 697.19 8,658.6

20 (500) 866.51 10,761

24 (600) 1,253.2 15,564

30 (750) 2006.0 24,913

36 (900) 2,935.0 36,451

40 (1000) 3,652.1 45,357

42 (1050) 4,115.1 51,107

48 (1200) 5,407.6 67,159

Velocity = Flow Rate Factor

EmersonProcess.com/Rosemount

Table 6. Line Size vs. Velocity/Rate

Nominal line size in inches

(mm)

Minimum/maximum flow rate

Gallons per minute Liters per minute at 0.04 ft/s (low-flow cutoff) at 1 ft/s (min range setting) at 3 ft/s at 39.37 ft/s (max range setting) at 0.012 m/s (low-flow cutoff) at 0.3 m/s (min range setting) at 1 m/s at 12 m/s (max range setting)

1/2 (15) 0.038 0.947 2.841 37.287 0.141 3.529 11.76 141.15

1 (25) 0.108 2.694 8.081 106.05 0.401 10.04 33.45 401.46

11/2 (40) 0.254 6.345 19.04 249.82 0.946 23.64 78.81 945.67

2 (50) 0.418 10.459 31.38 411.77 1.559 38.97 129.89 1,558.7

21/2 (65) 0.597 14.923 44.77 587.51 2.224 55.60 185.33 2,224.0

3 (80) 0.922 23.042 69.13 907.17 3.434 85.85 286.17 3,434.0

4 (100) 1.587 39.679 119.04 1,562.2 5.913 147.84 492.78 5,913.4

5 (125) 2.494 62.356 187.07 2,454.9 9.293 232.33 774.42 9,293.0

6 (150) 3.602 90.048 270.14 3,545.2 13.42 335.50 1,118.3 13,420

8 (200) 6.237 155.93 467.79 6,138.9 23.24 580.96 1,936.5 23,238

10 (250) 9.831 245.78 737.34 9,676.3 36.63 915.73 3,052.4 36,629

12 (300) 14.10 352.51 1,057.5 13,878 52.54 1,313.4 4,378.0 52,535

14 (350) 16.87 421.71 1,265.1 16,603 62.85 1,571.2 5,237.3 62,848

16 (400) 22.03 550.80 1,652.4 21,685 82.09 2,052.2 6,840.6 82,087

18 (450) 27.89 697.19 2,091.6 27,448 103.90 2,597.6 8,658.6 103,903

20 (500) 34.66 866.51 2,599.5 34,114 129.14 3,228.4 10,761 129,137

24 (600) 50.13 1,253.2 3,759.6 49,339 186.77 4,669.2 15,564 186,769

30 (750) 80.24 2,006.0 6,018.0 78,976 298.96 7,474.0 24,913 298,959

36 (900) 117.40 2,935.0 8,805.1 115,553 437.42 10,935 36,451 437,416

40 (1000) 146.09 3,652.1 10,956 143,785 544.29 13,607 45,357 544,286

42 (1050) 164.60 4,115.1 12,345 162,011 613.28 15,332 51,107 613,278

48 (1200) 216.30 5,407.6 16,223 212,898 805.91 20,148 67,159 805,908

EmersonProcess.com/Rosemount

Upstream/downstream piping length

To ensure specification accuracy over widely varying process conditions, install the sensor with a minimum of five straight pipe diameters upstream and two straight pipe diameters downstream from the electrode plane. See Figure 1.

Figure 1. Upstream and Downstream Straight Pipe Diameters

A. Five pipe diameters B. Two pipe diameters

Installations with reduced upstream and downstream straight runs are possible. In reduced straight run installations, the meter may not meet absolute accuracy specifications. Reported flow rates will still be highly repeatable.

Sensor grounding

A reliable ground path is required between the sensor and the process fluid. Optional grounding rings, and a process reference electrode are available with sensors to ensure proper grounding.

See Table 15 and Table 16.

A B

Flow

EmersonProcess.com/Rosemount

Ordering Information

Rosemount 8750W Magnetic Flowmeter Platform

The Rosemount 8750W Magnetic Flowmeter is available in a flanged sensor design. The sensors are fabricated from stainless and carbon steel and welded to provide a sealed coil housing that protects against moisture or other contaminants. Sizes range from 1/2-in. (15 mm) to 48-in. (1200 mm). The field mount transmitter has a die cast aluminum housing for excellent reliability. The wall mount transmitter features an easy to use operator interface. Both transmitter styles are available with advanced diagnostics to provide the best insight into the process and the meter's health.

Table 7. Rosemount 8750W Ordering Information

★ The starred offerings represent the most common options, and should be selected for best delivery.

Model Product description

8750W Magnetic Flowmeter System (utility, water, and wastewater)

Sensor design revision

D Revision “D”

Transmitter class

E(1) Revision 3 electronics ★

M Revision 4 electronics ★

0 Spare sensor, no transmitter

Transmitter mount

T Integral field mount ★

R Remote field mount ★

W Remote wall mount ★

Transmitter power

1 AC power supply (90–250 VAC, 50–60 Hz) ★

2 DC power supply (12–42 VDC) ★

0 Spare sensor, no transmitter

Transmitter outputs

A 4–20mA; Digital HART; Scalable Pulse ★

0 Spare sensor, no transmitter

Conduit entries

Integral mount qty (2), remote mount qty (4)

1 1/2–14 NPT ★

2 M20 ★

Integral mount qty (3), remote mount qty (5)

4 1/2–14 NPT, additional entry ★

5(2) M20, additional entry ★

0 Spare sensor, integral mount only, no transmitter

EmersonProcess.com/Rosemount

Sensor style

F Flanged ★

0 Spare transmitter, no sensor

Lining material

T(3) PTFE ★

P(4) Polyurethane ★

N(5) Neoprene ★

0 Spare transmitter, no sensor

Electrode material

S 316L stainless steel ★

H Nickel alloy 276 (UNS N10276) ★

0 Spare transmitter, no sensor

Electrode type

A 2 Measurement electrodes - standard ★

B 2 Measurement electrodes- bulletnose ★

E(6) 2 Measurement plus 1 reference electrode - standard ★

F(6) 2 Measurement plus 1 reference electrode - bulletnose ★

0 Spare transmitter, no sensor

Table 7. Rosemount 8750W Ordering Information

★ The starred offerings represent the most common options, and should be selected for best delivery.

EmersonProcess.com/Rosemount

• = Available

– = Unavailable

Line size

PTFE

code T Polyurethane code P Neoprene code N

005 1/2-in. (15 mm) • – –

010 1-in. (25 mm) • • •

015 11/2-in (40 mm) • • •

020 2-in. (50 mm) • • •

025 2 1/2-in. (65 mm) • – •

030 3-in. (80 mm) • • •

040 4-in. (100 mm) • • •

050 5-in. (125 mm) • – •

060 6-in. (150 mm) • • •

080 8-in. (200 mm) • • •

100 10-in. (250 mm) • • •

120 12-in. (300 mm) • • •

140 14-in. (350 mm) • • •

160 16-in. (400 mm) • • •

180 18-in. (450 mm) • • •

200 20-in. (500 mm) • • •

240 24-in. (600 mm) • • •

300 30-in. (750 mm) • • •

360 36-in. (900 mm) • • •

400 40-in. (1000 mm) – – •

420 42-in. (1050 mm) – • •

480 48-in. (1200 mm) – – •

000 Spare transmitter, no sensor – – –

Flange type and material(7)

C Slip-on, raised-face, carbon steel ★

S Slip-on, raised-face, 304/304L SST ★

F Slip-on, flat-face, carbon steel

G Slip-on, flat-face, 304/304L SST

0 Spare transmitter, no sensor

EmersonProcess.com/Rosemount

Flange rating(7)

A1 ASME B16.5, Class 150

Refer to Table 8 for flange availability.

A3 ASME B16.5, Class 300

AD AWWA C207 Class D (line size 30-in. and above)

AE AWWA C207 Class E (line size 30-in. and above)

AF AWWA C207 Class F (line size 30-in. and above)

DD EN1092-1, PN10

DE EN1092-1, PN16

DF EN 1092-1, PN25

DH EN 1092-1, PN40

GD GB/T9119, PN10

GE GB/T9119, PN16

GH GB/T9119, PN40

JP JIS B2220, 10K

JR JIS B2220, 20K

KU AS4087, PN16

KW AS4087, PN21

KY AS4087, PN35

TK AS2129, Table D

TL AS2129, Table E

00 Spare transmitter, no sensor

Options (must be included in the model number if selected - not required)

Safety approvals

Ordinary Location(8) No code required ★

Factory Mutual (FM)

Z5 FM Non-Incendive, Class I Div 2 for Non-Flammable Fluids; DIP ★

CSA

Z6 CSA, Class I Div 2 for Non-Flammable Fluids; DIP ★

ATEX

Z1 ATEX Non-Sparking and Dust for Non Flammable Fluids ★

ND ATEX Dust ★

IECEx

Z7 IECEx Non-Sparking and Dust for Non-Flammable Fluids ★

NF IECEx Dust ★

NEPSI

Z3 NEPSI Non-Sparking and Dust for Non-Flammable Fluids ★

EmersonProcess.com/Rosemount

Advanced Diagnostics Suite

DA1 Process diagnostics HPN, grounding/wiring, electrode coating ★

DA2 SMART Meter verification ★

Discrete input/output

AX(9) Two discrete channels (DI/DO 1, DO 2) ★

Display options

M4 Local operator interface ★

M5 LCD display only ★

Optional ground rings

G1 316L stainless steel (Qty 2) ★

G2 Nickel alloy C-276; UNS N10276 (Qty 2)

G5 316L stainless Steel (Qty 1) ★

G6 Nickel alloy C-276; UNS N10276 (Qty 1)

Certifications

PD European Pressure Equipment Directive Certification (PED, per 97/23/EC)

CR Canadian Registration Number (CRN) Certification

BD ASME B31.3 Process Piping Standard

DW(10) NSF Drinking Water Certification

Other options

C1 Custom configuration (CDS required)

D1 High accuracy calibration (base ref accuracy 0.25% of rate)

B6 316 SST 4-bolt kit for 2 inch pipe mount

P05(11) 5-Point verification

P10(12) 10-Point verification

Submergence protection

R05 Potted junction box with 50 feet of combo cable/cable gland

R10 Potted junction box with 100 feet of combo cable/cable gland

R15 Potted junction box with 150 feet of combo cable/cable gland

R20 Potted junction box with 200 feet of combo cable/cable gland

R25 Potted junction box with 250 feet of combo cable/cable gland

R30 Potted junction box with 300 feet of combo cable/cable gland

Special paint

V1 Coal tar paint (submersible/direct burial)

EmersonProcess.com/Rosemount

Quality certificates

Q4 Calibration certificate per ISO 10474 3.1B/EN 10204 3.1

Q8 Material traceability per ISO 10474 3.1B/EN 10204 3.1

Quick Start Guide (QSG) language options (default is English)

YA Danish ★

YB Hungarian ★

YC Czech ★

YD Dutch ★

YE Bulgarian ★

YF French ★

YG German ★

YH Finnish ★

YI Italian ★

YJ Japanese ★

YL Polish ★

YM Chinese (Mandarin) ★

YN Norwegian ★

YP Portuguese ★

YR Russian ★

YS Spanish ★

YW Swedish ★

Typical model number: 8750WDMT1A1FPSA010CA1DA2

1. Wall mount transmitter only.

2. Not available with the wall mount transmitter.

3. Available in 1/2- to 36-in. (15 mm to 900 mm) line sizes.

4. Available in line sizes 1- to 36-, and 42-in. (25 mm to 900 mm, and 1050 mm) line sizes.

5. Available in line sizes 1- to 48-in. (25 mm to 1200 mm) line sizes.

6. Not available in 1/2-in. (15mm).

7. Refer to Table 8 for flange offering.

8. FM marked, CSA marked, CE marked, EAC marked and C-tick marked.

9. Requires Conduit Entry code 4 or 5 with field mount transmitter.

10. NSF drinking water certification is available with the PTFE liner in line sizes 0.5- to 36-in (15 mm to 900 mm) and the polyurethane liner in line sizes 3- to 36-, and

42-in. (80 mm to 900 mm, and 1050 mm).

11. Available for 1/2- to 24-in (15 mm to 600 mm) at velocities 1, 3, 5, 7, 10 ft/s; 30-in. (700 mm) at velocities 1, 3, 5, 7, 9.5 ft/s; 36-in. (900 mm) at velocities 1, 2, 3, 5, 6.5 ft/s; 40- to 48-in. (1000 mm to 1200 mm).

12. Available for 1/2- to 24-in. (15 mm to 600 mm) at velocities 1, 2, 3, 4, 5, 6, 7, 8, 9, 10 ft/s; 30- to 48-in. (700 mm to 1200 mm) not available.

EmersonProcess.com/Rosemount

Table 8. Flowmeter Availability – Line Size vs. Flange Type and Rating

Ordering procedure

To order, select the desired sensor and/or transmitter by specifying model codes from the ordering table.

For remote transmitter applications, note the cable specification requirements.

Standard configuration

Unless the Configuration Data Sheet is completed, the transmitter will be shipped as follows:

Integrally Mounted Rosemount 8750W Transmitters are factory configured with the paired sensor size and appropriate calibration number.

Custom configuration (Option Code C1)

If Option Code C1 is ordered, the Configuration Data Sheet (CDS) must be submitted at the time of order.

Standard tagging

Instrument tags for the transmitter and sensors are as follows:

316SST laser etched label, permanently attached

Main label - Tag name:

1 line 21characters

Additional 316SST 'wire-on' tag available:

5 lines, 17 characters per line (6mm height)

• = Available

– = Not applicable

Flange rating

Flange type 005 010 015 020 025 030 040 050 060 080 100 120 140 160 180 200 240 300 360 400 420 480

A1 ASME 150 • • • • • • • • • • • • • • • • • – – – – –

A3 ASME 300 • • • • • • • • • • • • • • • • • – – – – –

AD AWWA Class D – – – – – – – – – – – – – – – – – • • • • •

AE AWWA Class E – – – – – – – – – – – – – – – – – • • • • •

AF AWWA Class F – – – – – – – – – – – – – – – – – • • – – –

DD EN 1092-1 PN10 – – – – – – – – – • • • • • • • • – • • – •

DE EN 1092-1 PN16 – – – • • • • • • • • • • • • • • – • • – –

DF EN 1092-1 PN 25 – – – – – – – – – • • • • • • • • – – – – –

DH EN 1092-1 PN 40 • • • • • • • • • • • • • • • • • – – – – –

GD GB/T PN10 – – – – – – – – – • • • • • • • • – • • – –

GE GB/T PN16 – – – – – – • • • • • • • • • • • – • • – –

GH GB/T PN40 • • • • • • • • • • • • • • • • • – – – – –

JP JIS B2220 10k • • • • • • • • • • • • • • • • • – – – – –

JR JIS B2220 20k • • • • • • • • • • • • • • • • • – – – – –

KU AS4087 PN16 – – – • • • • • • – • • • • • • • • • • – –

KW AS4087 PN21 – – – • • • • • • – • • • • • • • • • • – –

KY AS4087 PN35 – – – • • • • • • – • • • • • • • • • – – –

TK AS2129 TABLE D • • • • • • • • • • • • • • • • • • • • – •

TL AS2129 TABLE E • • • • • • • • • • • • • • • • • • • • – •

Engineering units ft/sec

4 mA 0

20 mA 30

Sensor size 3-in.

Empty pipe On

Sensor calibration number 1000005010000000

EmersonProcess.com/Rosemount

Cable requirements for remote transmitters

Remote mount transmitter installations will require equal lengths of interconnecting cables for the coil drive (1, 2, 3) and the electrode cable (17, 18, 19).

The interconnecting cables can be either individual component cables or a combination coil drive and electrode cable. Review hazardous area approval requirements.

When ordering remote cables be sure to review the installation requirements for proper cable selection. Integrally mounted transmitters are factory wired and do not require additional interconnecting cables.

Component cable lengths should be limited to less than 500 feet (150 m). Consult factory for length between 500–1000 feet (150–300 m).

For installations using the combination coil drive and electrode cable, lengths should be limited to less than 330 feet (100 m).

Cables kits are available as individual component cables or as a combination coil/electrode. Remote cables can be ordered direct from Emerson Process Management using the kit numbers shown in Table 9 and Table 10. Equivalent Alpha cable part numbers are also provided as an alternative. To order cable, specify length as quantity desired. Equal length of component cable is required.

Example:

25 feet = Qty (25) 08732-0065-0001

Table 9. Component Cable Kits

Cable kit number Description Individual cable Alpha p/n

Standard temperature (-20 °C to 75 °C)

08732-0065-0001 (feet) Kit, component cables, std temp.

(includes coil + electrode)

Coil Electrode

518243 518245

08732-0065-0002 (meters) Kit, component cables, std temp.

(includes coil + electrode)

Coil Electrode

518243 518245

08732-0065-0003 (feet) Kit, component cables, std temp.

(includes coil + I. S. electrode)

Coil Intrinsically safe blue electrode

518243 518245

08732-0065-0004 (meters) Kit, component cables, std temp.

(includes coil + I. S. electrode)

Coil Intrinsically safe blue electrode

518243 518245

Extended temperature (-50 °C to 12 5 °C)

08732-0065-1001 (feet) Kit, component cables, ext temp.

(includes coil + electrode)

Coil Electrode

840310 518189

08732-0065-1002 (meters) Kit, component cables, ext temp.

(includes coil + electrode)

Coil Electrode

840310 518189

08732-0065-1003 (feet) Kit, component cables, ext temp.

(includes coil + I. S. electrode)

Coil Intrinsically safe blue electrode

840310 518189

08732-0065-1004 (meters) Kit, component cables, ext temp.

(includes coil + I. S. electrode)

Coil Intrinsically safe blue electrode

840310 518189

Table 10. Combination Cable Kits

Coil and electrode cable (-20 °C to 80 °C)

Cable kit number Description

08732-0065-2001 (feet) Kit, combination cable, standard

08732-0065-2002 (meters)

08732-0065-3001 (feet) Kit, combination cable, submersible (80 °C dry/60 °C wet)(33-ft. continuous)

08732-0065-3002 (meters)

EmersonProcess.com/Rosemount

Specifications

The tables below outline some of the basic performance, physical, and functional specifications of the Rosemount 8750W Magnetic Flowmeter. Table 11 provides an overview of the Rosemount 8750W Transmitters available. Table 12 provides an overview of the Rosemount 8750W Sensors available.

Table 11. Transmitter Specifications

Table 12. Sensor Specifications

Transmitter Style Mount Base accuracy Power supply

User interface

Communication protocol

Diagnostics Detailed specifications Ordering information

Field mount

Integral or

Remote

0.5% Standard 0.25% High

Accuracy Option

Global AC or

DC

4 Optical Switch LOI

HART Basic, DA1, DA2 Page 17 Page 7

Display only

Wall mount(1)(2)

1. Electrode coating diagnostic is not available with the wall mount transmitter.

2. Continuous Smart Meter verification is not available with the wall mount transmitter.

Remote 0.5% Standard

0.25% High Accuracy Option

Global AC or

DC

Dedicated 15-Button

LOI

HART Basic, DA1, DA2 Page 21 Page 7

Sensor Style Base accuracy Line sizes Design features Detailed specifications Ordering information

Flanged 0.5% Standard 0.25% High Accuracy Option

1/2- to 48-in.

(15 mm to 1200 mm) Standard design Page 25 Page 7

EmersonProcess.com/Rosemount

Table 14. Electrode Material Selection

Table 15. Process Reference Option

Table 13. Lining Material Selection

Liner material General characteristics

PTFE • Chemical resistance

• Excellent high temperature capabilities

• -20 to 248 °F (-29 to 120 °C)

Polyurethane • Limited chemical resistance

• Excellent abrasion resistance for slurries with small and medium particles

• 0 to 140 °F (-18 to 60 °C)

Neoprene • Very good abrasion resistance for small and medium particles

• Better chemical resistance than polyurethane

• Typically applied in applications containing chemicals and sea water

• 0 to 176 °F (-18 to 80 °C)

Electrode material General characteristics

316L Stainless Steel

• Good corrosion resistance

• Good abrasion resistance

• Not recommended for sulfuric or hydrochloric acids

Nickel Alloy 276

(UNS N10276)

• Better corrosion resistance

• High strength

• Good in slurry applications

• Effective in oxidizing fluids

Electrode type General characteristics

Standard Measurement • Lowest cost

• Good for most applications

Measurement + Reference Electrode (Also see Table 15 and Table 16 for grounding options and installation

• Low cost grounding option especially for large line sizes

• Minimum conductivity of 100 microSiemens/cm

• Not recommended for electrolytic or galvanic corrosion applications

Bulletnose

• Extended head protrudes into the flow stream for self-cleaning

• Best option for coating processes

Grounding options General characteristics

No grounding options (grounding straps)

• Acceptable for conductive unlined pipe

• Grounding straps provided at no cost

Reference electrode

• Same material as measurement electrodes

• Sufficient grounding option when process fluid conductivity is greater than 100 microSiemens/cm

• Not recommended in electrolysis applications, galvanic corrosion applications, or applications where the electrodes may coat.

Grounding ring/rings

• Low conductivity process fluids

• Cathodic or electrolysis applications that may have stray currents in or around the process

• Variety of materials for process fluid compatibility

Table 16. Process Reference Installation

Type of pipe Grounding straps Grounding rings Reference electrode Lining protectors

Conductive unlined pipe Acceptable Not required Not required Not required

Conductive line pipe Not acceptable Acceptable Acceptable Acceptable

Non-conductive pipe Not acceptable Acceptable Not acceptable Acceptable

EmersonProcess.com/Rosemount

Rosemount 8750W Field Mount Transmitter Specifications

Functional specifications

Transmitter coil drive current

500 mA

Flow rate range

Capable of processing signals from fluids that are traveling between 0.04 and 39 ft/s (0.01 to 12 m/s) for both forward and reverse flow in all sensor sizes. Full scale continuously adjustable between –39 and 39 ft/s (–12 to 12 m/s).

Conductivity limits

Process liquid must have a conductivity of 5 microSiemens/cm (5 micromhos/cm) or greater.

Power supply

90 - 250 VAC, 50/60 Hz or 12 - 42 VDC

Line power fuses

90-250 VAC systems

1A, 250V, I2t ≥ 1.5 A2s Rating, Fast Acting

Bussman AGC-1, Littelfuse 31201.5HXP

12-42 VDC systems

3 Amp, 250V, I2t ≥ 14 A2s Rating, Fast Acting

Bel Fuse 3AG 3-R, Littelfuse 312003P, Schurter 0034.5135

Power consumption

15 W…