Attachment 04 - MH-107-0518101-ATL SBT Mechanical Penthouse.pdf

PDF 673 KB Posted

Attached to
C223--Replace Community Living Center and South Bed Tower Chillers
Solicitation number
36C24822R0086
Issued by

About this file

This sources sought notice requests Standard Form 330 qualification packages from architecture and engineering firms for the replacement of chillers at the VA Caribbean Healthcare System in San Juan, Puerto Rico. Firms must be SDVOSB certified and licensed in Puerto Rico. The project scope involves design and construction documents for replacing the Community Living Center and South Bed Tower chillers. The construction value is estimated between $2-5 million. Responses are due by April 28, 2022 and firms will be evaluated on their qualifications, specialized experience with healthcare and renovation projects, capacity, past performance, location, reputation, and claims history. The selected firm may also provide construction period services.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

S7-3

STAIR

S7-1

S7-2

PH-6

SWITCHGEAR ROOM

EMERGENCY

PH-2

SWITCHGEAR ROOM

CPH-1

CORRIDOR

PH-1

ELEVATOR

MACHINE ROOM

PH-3

MECHANICAL ROOM

PH-4

CONTROL ROOM

FEC

FE

FE

FEC

FEC

FE

FE

FE

FEC

A B C D E F G H J K L MA.8 K.8

1.2

1.3

F.3

T

J J

TT

AHU-1

AHU-2 AHU-3

AHU-4

AHU-5

AHU-6 AHU-7

CH-1

CH-2

CT-2

CT-1

DUCT, DN

18X26 EA

DUCT, DN

18X26 EA

& CHEMICALS

CONTROLS

WATER T’MT

12" CWR

16" CWS

10" CHR

O/A PLENUM

O/A PLENUM O/A PLENUM O/A PLENUM

DN

12" CWS

12" CWR

4" BYPASS

10" INLET

12" OUTLET

BOD=10’-0"

56X44 44X31

3’-9"

BOD=

56X40

FD

TO ROOF

DUCT, DN

18X24 EA

TO ROOF

BOD=10’-6"

34X36

BOD=10’-6"

34X36

FD

BOD=10’-6"

36X34

BOD=10’-6"

36X34

BOD=10’-6"

36X34

B O

D

X

BOD=10’-6"

36X34

FOT

6" MPS

2"PCR

10" CHWR TO CENTRAL PLANT - RUN HIGH

10" CHWS FROM CENTRAL PLANT - RUN HIGH

3" CWR - RUN HIGH

3" CWS - RUN HIGH

4" HWR - RUN LOW

4" HWS - RUN LOW

PLUMBING PIPE, SEE PLUMBING FOR INFO

4"HWS

4"HWR

CHEM TM’T

4" MPS

5"MPS

C W

S

R

FD

FD

FD

FD

FD

FDFDFD

FD

FDFD

FD

FD

FD

FDFD

FD

FD

BOD=10’-6"

36X34

BOD=11’-4"

36X34

BOD=10’-6"

34X36

BOD=10’-6"

36X34

BOD=10’-6"

36X34

FDFD

BOD=10’-6"

36X34

FDFD

BOD=10’-6"

36X34

BOD=10’-6"

34X36

GEF-1

BOD=3’-6"

90X24

ROOM MONITORING PANEL

SCBA CABINET AND REFRIGERATION

EPO

EPO

EPO

ALARM HORN AND STROBE (TYP.)

EMERGENCY POWER OFF SWITCH,

O/A PLENUM

SSCU-2

SSFCU-2

SLOPE TO PRV STATION

4" HPS (100#) FROM BOILER PLANT - RUN LOW,

SLOPE TO SHAFT

2" PUMPED COND. RETURN TO BOILER PLANT - RUN LOW,

REDUCING STATION

STEAM PRESSURE

BOD=10’-6"

34X36

H

S

FD

PLUMBING

SEE

HEATERS

WATER

DOMES.

RISE

RISE RISE

10" CHR

R

S

RISE

8" CHS

10" CHS FROM CEP

CONNECTION

12" EQUALIZER

FD

FLOOR

ABOVE

9’-7"

SG-3

FLOOR

LOW TO

RG-3

ON FLOOR

SSFCU-3,

(BELOW PIPING)

30X22, BOD=9’-6"

DN

10" CHS

R

E Q

U A

L

IZ

E R

AS-1

CHP-1

CHP-2

ET-1

CHP VSD’S

CP-3CP-2CP-1

FM

FM

FM

S

R

S

R

8"CHS

8"CHR

6" CHR

6" CHS

4" CHS

4" CHR

DP

4"

R.O. (TYP.)

3" CHS&R

4" MPS

DN

10" CHR TO CEP

RR

HWP-2

HWP-1

AS-2

CRU-1

ET-2

HX-1

BF-2

FH-4

IEF-4 IEF-5

FH-5

IEF-6 FH-6

V-1

GEF-2

AHU-12

AHU-11

AHU-10

FH-2

IEF-2

FH-1

IEF-1

FM

FM-4

FM-1

FH-3

IEF-3

FM-3

FM-2

ROOF

DUCT TO

DUCT, DOWN

18X24 EA

BOD=10’-6"

36X34

ROOF

DUCT TO

DUCT, DN

12X14 EA

TO ROOF

DUCT

TO ROOF

DUCT, DN

18X36 EA

DOWN TO FLOOR

3’-0" DEEP SHEETMETAL PLENUM BEHIND,

BOTTOM 8’-0" ABOVE FLOOR. PROVIDE

7’-0"X8’-0" LOUVER WITH BIRDSCREEN

THROUGH ROOF

SRV 6" DISCHARGE

BOD=11’-4"

36X34

BEHIND, DOWN TO FLOOR

4’-0" DEEP SHEETMETAL PLENUM

BOTTOM 5’-0" ABOVE FLOOR. PROVIDE

21’-4"X4’-0" LOUVER W/BIRDSCREEN,

BEHIND, DOWN TO FLOOR

4’-0" DEEP SHEETMETAL PLENUM

BOTTOM 5’-0" ABOVE FLOOR. PROVIDE

21’-4"X4’-0" LOUVER W/BIRDSCREEN,

BEHIND, DOWN TO FLOOR

3’-0" DEEP SHEETMETAL PLENUM

BOTTOM 5’-0" ABOVE FLOOR. PROVIDE

9’-0"X4’-0" LOUVER W/BIRDSCREEN,

BEHIND, DOWN TO FLOOR

3’-0" DEEP SHEETMETAL PLENUM

BOTTOM 5’-0" ABOVE FLOOR. PROVIDE

9’-0"X4’-0" LOUVER W/BIRDSCREEN,

BEHIND, DOWN TO FLOOR

4’-0" DEEP SHEETMETAL PLENUM

BOTTOM 5’-0" ABOVE FLOOR. PROVIDE

21’-4"X4’-0" LOUVER W/BIRDSCREEN,

BOD=12’-10"

56X44

FOT

2’-0" DEEP SHEETMETAL PLENUM BEHIND

BOTTOM 12’-0" ABOVE FLOOR. PROVIDE

16’-0"X4’-0" LOUVER W/BIRDSCREEN,

DOWN TO FLOOR

3’-0" DEEP SHEETMETAL PLENUM BEHIND,

BOTTOM 8’-0" ABOVE FLOOR. PROVIDE

12’-0"X8’-0" LOUVER W/BIRDSCREEN

BDD

(TYP)

STOBE AND HORN

REFRIGERANT ALARM

(TYP. 2)

MONITOR

REFRIGERANT

R

IS

E

BOD=13’-5"

56X44

RAF-12

RAF-11

RAF-10RAF-9

RAF-6

RAF-4

RAF-3

RAF-2

RAF-1

90X12

90X12

BOD=8’-0"

90X24

8’-0"

BOD=

90X24

PLENUM BEHIND, DOWN TO FLOOR

4’-0" DEEP X10’-6" TALL SHEETMETAL

BOTTOM 5’-0" ABOVE FLOOR. PROVIDE

25’-0"X4’-0" LOUVER W/BIRDSCREEN,

PLENUM BEHIND, DOWN TO FLOOR

4’-0" DEEP X10’-6" TALL SHEETMETAL

BOTTOM 5’-0" ABOVE FLOOR. PROVIDE

19’-0"X4’-0" LOUVER W/BIRDSCREEN,

EPO

(4)

SR

B O

D

X

SSFCU-1, ON FLOOR

S-3SA

36X36

36X34

36X34

S

S A

36X36

36X36

AND AAV

VACUUM BREAKER

AND AAV

BREAKER

VACUUM

FD

M

M M

2" RS, 1-3/8" RL

O/A PLENUM

O/A PLENUM

3/4" RS

3/8" RL,

AHU-9AHU-8

RAF-8

ROOF CURB

FLASHABLE

STRUCTURAL

ATTACH TO A

SSCU-4

ROOF CURB

FLASHABLE

STRUCTURAL

ATTACHED TO A

3" CHWS&R

DOWN

OGEE

BOD=7’-9"

56X96

BOD=12’-6"

130X20

3"

BOTTOM 4’-0" ABOVE FLOOR

12’-0"X12’-0" LOUVER W/BIRDSCREEN,

PIPING HIGH

ROUTE REFRIGERANT

TO SSFCU-4

X

X

20X16

X

(4) 12X12

SG-2

12X6

SG-2

12X6

SG-2

12X6

SG-2

SSFCU-4

(TYP. 2)

16X18 DOWN

44X56

BOD=8’-10"

30X18, SR

M

A

M

M

FA

G

EXISTING VA HOSPITAL

ADDITION

Office of

Facilities

Management

FULLY SPRINKLERED

SHEET TITLE PROJECT NUMBER

BUILDING NUMBER

DRAWING NUMBERSCALE

NORTH

PROJECT

NORTH

TRUE

DATE

DRAWN

STAMPKEY PLANDATE

CHECKED

CONSULTANTS: PROJECT NAME

ATLANTA, GEORGIA 30309

999 PEACHTREE STREET, NE

HEERY INTERNATIONAL, INC.

0 8’ 16’

1/8" = 1’-0"

NEW

SALEM, IN 47167

601 ANSON STREET, SUITE 101

DEARINGER CENTER

EQUIPMENT SYSTEMS PLANNING, INC.

SAN JUAN, PUERTO RICO

NEW PATIENT BED BUILDING

DEPARTMENT OF VETERANS AFFAIRS

N/A

05181-01

ISSUES

EQUIPMENT SYSTEMS PLANNING, INC.

08/21/06

FINAL SUBMITTAL

o n e e ig h t h in c h o n e f o o t 1

B

A

C

D

E

F t h r e e in c h e s e f o o t o n e a d a lf in c h s e f o o t o n e in e f o o t t h r q u a r t e r s in e f o o t o a lf in e f o o t t h r e e e ig h t h s in e f o o t o q u a r t e r in e f o o t

VA FORM 08-6231, OCT 1978

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

MH-107

KDM

HMS

08/21/06

HVAC PLAN

30% SUBMITTAL PENTHOUSE FLOOR

95% SUBMITTAL 10/09/06

KEYED NOTES:

131313

MH-302

MH-302

MH-301

MH-301

15 15

171717

FINAL SUBMITTAL 11/11/06

19 18

24 1

1 REVISION #1 02/14/07

27 27 27

2 REVISION #4 04/15/08

3 REVISION #5 05/26/08

4 REVISION #6 07/04/08

5 MSK7 03/10/09

6 MSK9 03/10/09

RECORD DOCUMENT 12/25/09

7 06/15/10POST-TURNOVER REVISION

(APPLIES TO MH-107 ONLY)

SEE DRAWING 2/AF-201. SEE MH-701.

PROVIDE TWO 6’-0" LONG X 3’-0" HIGH HOISTWAY VENT LOUVERS AND MOTORIZED DAMPERS.

IN ROOM PH-6)

TRANSFORMERS

(TYPICAL 4

FAN SPEED.

STRUT-MOUNTED VARIABLE FREQUENCY DRIVE, CONTROLLER IS ISOLATION ROOMS’ EXHAUST

COORDINATE DUCT ROUTING WITH ELEVATOR EQUIPMENT FOOTPRINTS.

STRUT-MOUNTED VARIABLE FREQUENCY DRIVE, CONTROLLING RETURN FAN SPEED.

WALL-MOUNTED VARIABLE FREQUENCY DRIVE, CONTROLLING RETURN FAN SPEED.

SEE DRAWINGS ON AF-201.

STRUT-MOUNTED VARIABLE FREQUENCY DRIVE, CONTROLLING HEATING-WATER PUMP SPEED.

WALL-MOUNTED VARIABLE FREQUENCY DRIVE, CONTROLLING CHILLED-WATER PUMP SPEED.

STRUT-MOUNTED VARIABLE FREQUENCY DRIVE, CONTROLLING ADJACENT AIR HANDLER FAN SPEED.

WALL-MOUNTED VARIABLE FREQUENCY DRIVE, CONTROLLING ADJACENT AIR HANDLER FAN SPEED.

WALL-MOUNTED VARIABLE FREQUENCY DRIVE, CONTROLLING TOWER FAN SPEED.

LOCATION OF MAIN HVAC CONTROL PANELS.

LOCATION OF POWER MONITORING CONTROL SERVER. SEE EP-107.

LOCATION OF ECC (ONE OF TWO), ON DESK. SEE 15902.

(DELETED).

(DELETED)

SEE "TYPICAL PIPE ANCHOR/SUPPORT DETAIL" ON MH-502.

PROVIDE PIPE ANCHOR AT ELEVATOR MACHINE ROOM FLOOR SLAB (APPROX. EL.=175’).

SEE MH-402

THERMOSTAT OPERATING FAN V-1 SPEED.

LOUVER , INTERLOCKED WITH FAN V-1, TO OPEN WHEN FAN V-1 OPERATES AT ITS HIGH SPEED.

PROVIDE A 144X96 MOTORIZED OPERATING DAMPER IN SHEETMETAL COLLAR HIGH BEHIND

STRUT-MOUNTED VARIABLE FREQUENCY DRIVE, CONTROLLING FAN V-1.

PIPE AIR-CONDITIONING UNIT CONDENSATE FROM P-TRAP TO SPILL INTO FLOOR DRAIN.

ISOLATE TRANSFORMER WITH 0.30-INCH STATIC DEFLECTION ELASTOMERIC PAD-TYPE ISOLATORS.

(2) 1-1/8" RS AND (2) 3/8" RL. SPLIT SYSTEM MANUFACTURER TO CONFIRM PIPE SIZES.

ATTACH FAN-COIL TO A 4" HIGH CONCRETE HOUSEKEEPING PAD.

HOUSEKEEPING PAD.

ATTACH FAN-COIL UNIT TO A 8" TALL FLOORSTAND, IT ATTACHED TO A 4" HIGH CONCRETE

PROVIDE 6" WIDE FLEXIBLE FABRIC DUCT CONNECTOR AT FAN-COIL UNIT OUTLET COLLAR.

SPLIT SYSTEM MANUFACTURER TO CONFIRM PIPE SIZES.

SEE MH-108 FOR CONTINUATION.

REFRIGERANT PIPING TO SSFCU-3.

SEE DRAWING 3/AF-201. SEE MH-701.

PROVIDE ONE 6’-0" LONG X 3’-0" HIGH HOISTWAY VENT LOUVERS AND MOTORIZED DAMPERS.

VHASAJMARTIJ35

Text Box

SBT MECH PENTHOUSE

References
gg_ab01, gg_ab01-0518101-ATL.dgn, Default
s_nsg01, C:
_HII_PRJ
new-job
s_nsg01-0518101-ATL.dgn, Default
a_ncp04, C:
_HII_PRJ
new-job
a_ncp07-0518101-ATL.dgn, Default
a_nfp04, C:
_HII_PRJ
new-job
a_nfp07-0518101-ATL.dgn, Default
s_ncp04, C:
_HII_PRJ
new-job
s_ncp07-0518101-ATL.dgn, Default
a_nc08, a_ncp08-0518101-ATL.dgn, Default
m_nhp07, C:
_HII_PRJ
new-job
m_nhp07-0518101-ATL.dgn, Default
m_dee, EE-401-0518101-ATL.dgn, Default
m_dee02, EE-401-0518101-ATL.dgn, Default