Attachment 03 - Drawings 573-20-604 95 pages.pdf

PDF 31 MB Posted

Attached to
Y1DA--BB - Renovate Common Area Restrooms
Solicitation number
36C24825R0119
Issued by

About this file

This document is a set of architectural and engineering drawings for a renovation project at the Malcom Randall VA Medical Center in Gainesville, Florida. The project involves renovating common area restrooms throughout the Basement and First Floor of Building 1, E-Wing and ACA, as well as the First Floor of Building 12. The comprehensive drawing set includes detailed plans for demolition, plumbing, HVAC, electrical, and architectural modifications across multiple building areas.

The drawings cover extensive renovation work, including replacing fixtures, updating electrical and plumbing systems, modifying ceiling layouts, and upgrading restroom facilities. The project scope involves precise demolition and reconstruction of restrooms, with specific attention to accessibility requirements, electrical connections, and mechanical systems. The contract period is 730 calendar days from the Notice to Proceed, and the work encompasses detailed modifications to multiple building areas, ensuring comprehensive upgrades to the medical center's restroom infrastructure.

View the file

Other files

Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SHEET INDEX

G001

SHEET

NO. DRAWING TITLE

GENERAL

G002

ARCHITECTURAL

SHEET

NO.

COVER SHEET

GENERAL NOTES, DETAILS, ABBREVIATIONS AND LEGENDS

LOCATION MAP

NOT TO SCALE

AREA MAP

NOT TO SCALE

OVERALL FIRST FLOOR DEMO PLAN - AREA F & GAD106

TRUE

NORTH

TRUE

NORTH

RENOVATE COMMON AREA RESTROOMS

PROJECT NO. 573-20-604

FINAL CONTRACT SUBMITTAL

MALCOM RANDALL VA MEDICAL CENTER

GAINESVILLE, FL 32608

PLAN

NORTH

PLAN

NORTH

OVERALL BASEMENT DEMO PLAN - AREA A, B, C & DAD101

OVERALL BASEMENT DEMO PLAN - AREA F & G

OVERALL FIRST FLOOR DEMO PLAN - AREA A, B, C & DAD104

OVERALL FIRST FLOOR DEMO PLAN - AREA EAD105

AD103

OVERALL BASEMENT DEMO PLAN - AREA EAD102

AD107 OVERALL FIRST FLOOR DEMO PLAN - BUILDING 12

A101 OVERALL BASEMENT PLAN - AREA A, B, C & D

PROJECT AREAPROJECT AREA

A102 OVERALL BASEMENT PLAN - AREA E

A103 OVERALL BASEMENT PLAN - AREA F & G

A104 OVERALL FIRST FLOOR PLAN - AREA A, B, C & D

A105 OVERALL FIRST FLOOR PLAN - AREA E

A106 OVERALL FIRST FLOOR PLAN - AREA F & G

A107 OVERALL FIRST FLOOR PLAN - BUILDING 12

A401 ENLARGED FLOOR PLANS - AREA A, B, C & D

A402 ENLARGED FLOOR PLANS - AREA A, B, C & D

A403 ENLARGED FLOOR PLANS - AREA E

A404 ENLARGED FLOOR PLANS - AREA F & G

A405 ENLARGED FLOOR PLANS - BUILDING 12

PLUMBING

OVERALL BASEMENT PLUMBING PLAN - AREA EP102

OVERALL BASEMENT DEMO PLUMBING PLAN - AREA A, B, C & D PD101

OVERALL BASEMENT DEMO PLUMBING PLAN - AREAS F & G

OVERALL FIRST FLOOR DEMO PLUMBING PLAN - AREA A, B, C & D PD104

P101

PD103

OVERALL BASEMENT DEMO PLUMBING PLAN - AREA EPD102

P103 OVERALL BASEMENT PLUMBING PLAN - AREAS F & G

P104 OVERALL FIRST FLOOR PLUMBING PLAN - AREAS A, B, C & D

P105 OVERALL FIRST FLOOR PLUMBING PLAN - AREA E

P106 OVERALL FIRST FLOOR PLUMBING PLAN - AREAS F & G

P107 OVERALL FIRST FLOOR PLUMBING PLAN - BUILDING 12

P401 ENLARGED PLUMBING FLOOR PLANS - BUILDING 1 AREA ABCD

P402 ENLARGED PLUMBING FLOOR PLANS - BUILDING 1 AREA ABCD

P403 ENLARGED PLUMBING FLOOR PLANS - AREA E

P404 ENLARGED PLUMBING FLOOR PLANS BUILDING 1 - AREAS F & G

P405 ENLARGED PLUMBING FLOOR PLANS BUILDING 12

OVERALL BASEMENT PLUMBING PLAN - AREAS A, B, C & D

A601 SCHEDULES, TYPES AND DETAILS - AREA A, B, C & D

A602 SCHEDULES, TYPES AND DETAILS - AREA E

A603 SCHEDULES, TYPES AND DETAILS - AREA F & G

A604 SCHEDULES, TYPES AND DETAILS - BUILDING 12

OVERALL FIRST FLOOR DEMO PLUMBING PLAN - AREA E PD105

OVERALL FIRST FLOOR DEMO PLUMBING PLAN - AREAS F & GPD106

OVERALL FIRST FLOOR DEMO PLUMBING PLAN - BUILDING 12PD107

MECHANICAL

OVERALL BASEMENT HVAC PLAN - AREAS A, B, C & D M101

OVERALL BASEMENT HVAC PLAN - AREAS F & G

OVERALL FIRST FLOOR HVAC PLAN - AREA A, B, C & D M104

M103

OVERALL BASEMENT HVAC PLAN - AREA EM102

OVERALL FIRST FLOOR HVAC PLAN - AREA E M105

OVERALL FIRST FLOOR HVAC PLAN - AREAS F & GM106

OVERALL FIRST FLOOR HVAC PLAN - BUILDING 12M107

M401 ENLARGED HVAC FLOOR PLANS - BUILDING 1 AREA ABCD

M402 ENLARGED HVAC FLOOR PLANS - BUILDING 1 AREA ABCD

M403 ENLARGED HVAC FLOOR PLAN - AREA E

M404 ENLARGED HVAC FLOOR PLAN - AREA F & G

M405 ENLARGED HVAC FLOOR PLANS - BUILDING 12

M500 HVAC DETAILS

ELECTRICAL

ELECTRICAL LEGEND AND NOTESE001

OVERALL BASEMENT ELECTRICAL PLAN - AREA F & G

OVERALL FIRST FLOOR ELECTRICAL PLAN - AREAS A, B, C & D E104

E102

OVERALL BASEMENT ELECTRICAL PLAN - AREAS A, B, C & DE101

OVERALL FIRST FLOOR ELECTRICAL PLAN - AREA E E105

OVERALL FIRST FLOOR ELECTRICAL PLAN - AREA F & GE106

OVERALL FIRST FLOOR ELECTRICAL PLAN - BUILDING 12E107

E401 ENLARGED ELECTRICAL PLANS - BUILDING 1 AREAS ABCD

E402 ENLARGED ELECTRICAL PLANS - BUILDING 1 AREAS ABCD

E403 ENLARGED ELECTRICAL PLANS - AREA E

E404 ENLARGED ELECTRICAL PLANS - BUILDING 1 AREA F&G

E405 ENLARGED ELECTRICAL PLANS - BUILDING 12

OVERALL BASEMENT ELECTRICAL PLAN - AREA E

E103

A451 INTERIOR ELEVATIONS - AREA A, B, C & D

A452 INTERIOR ELEVATIONS - AREA A, B, C & D

INTERIOR ELEVATIONS - AREA A, B, C & DA453

INTERIOR ELEVATIONS - AREA EA454

INTERIOR ELEVATIONS - AREA F & GA455

INTERIOR ELEVATIONS - BUILDING 12A456

AD111 OVERALL BASEMENT DEMO RCP - AREA A, B, C & D

AD112 OVERALL BASEMENT DEMO RCP - AREA E

AD113 OVERALL BASEMENT DEMO RCP - AREA F & G

OVERALL FIRST FLOOR DEMO RCP - AREA A, B, C & DAD114

OVERALL FIRST FLOOR DEMO RCP - AREA EAD115

OVERALL FIRST FLOOR DEMO RCP - AREA F & GAD116

OVERALL FIRST FLOOR DEMO RCP - BUILDING 12AD117

A111 OVERALL BASEMENT RCP - AREA A, B, C & D

A112 OVERALL BASEMENT RCP - AREA E

A113 OVERALL BASEMENT RCP - AREA F & G

OVERALL FIRST FLOOR RCP - AREA A, B, C & DA114

OVERALL FIRST FLOOR RCP - AREA EA115

OVERALL FIRST FLOOR RCP - AREA F & GA116

OVERALL FIRST FLOOR RCP - BUILDING 12A117

A411 ENLARGED RCP - AREA A, B, C & D

A412 ENLARGED RCP - AREA A, B, C & D

A413 ENLARGED RCP - AREA E

A414 ENLARGED RCP - AREA F & G

A415 ENLARGED RCP - BUILDING 12

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

Date:

Drawing Title:

Approved Project Director

Project Title:

1 2 3 4 5 6 7 8 9

FINAL CONTRACT

SUBMITTAL590 MEANS ST NW

Phase Project Number

Building Number

Drawing NumberLocation

Issue Date CheckedFULLY SPRINKLERED

STAMP

STE. 200

ATLANTA, GA 30318

ARCHITECT/ENGINEER OF RECORDCONSULTANT

A

B

C

D

E

F

U.S. Department of Veterans Affairs

Office of Construction and

Facilities Management

Drawn

1 & 12

SJ/EO/SMTS

573-20-604

COVER SHEET RENOVATE COMMON AREA

RESTROOMS

GAINESVILLE, FLORIDA

G001 03-21-2024 smittal Snapshot smittal Image smittal Text Box 03-21-2024

ARCHITECTURAL ABBREVIATIONS

GENERAL PROJECT NOTES

ALUMINUM COMPOSITE METAL PANELS

ACOUSTICAL CEILING TILE

ABOVE FINISH FLOOR

ALUMINUM

BATT INSULATION

BOTTOM OF

CEMENTITIOUS BACKER BOARD

CEMENTITIOUS CRYSTALLINE WATERPROOFING

COLD-FORMED METAL FRAMING

CORNER GUARD

CENTERLINE

CONCRETE MASONRY UNIT

CASED OPENING

COMMUNICATION

CONCRETE

SEALED CONCRETE

CONTINUOUS

CONTRACTING OFFICER'S REPRESENTATIVE

CERAMIC TILE

CERAMIC TILE BASE

CARPET

DIAMETER

EXPANSION JOINT

ELECTRICAL

EQUAL

EXPOSED STRUCTURE

ET CETERA

EXISTING

EXPOSED

FACTORY FINISH

FLOOR DRAIN

FIRE EXTINGUISHER CABINET

FIRE HOSE CABINET

FINISHED FLOOR

FINISH

FLOOR

FACE OF

FIELD VERIFY

FABRIC WALLCOVERING

GAGE

GRANITE

GYPSUM (WALL) BOARD

HANDICAPPED

HOLLOW METAL

HANDRAIL

HEATING VENTILATION AND AIR-CONDITIONING

MATERIAL

MAXIMUM

MECHANICAL

MANUFACTURER

MINIMUM

MASONRY OPENING

METAL

NOT IN CONTRACT

NOT TO SCALE

ON CENTER

OPPOSITE HAND

PLASTER

PLASTIC LAMINATE

PORCELAIN TILE

PAIR

PAINT

QUARRY TILE

RESILIENT BASE

REFRIGERATOR

REQUIRED

RESINOUS FLOORING

RESINOUS EPOXY WALL-CEILING

ROUGH OPENING

RUBBER FLOORING

RECESSED PAPER HOLDER

SEALED HIGH BUILD GLAZED COATING

SOLID CORE WOOD

SIMILAR

SPECIAL FACED

STAINLESS STEEL/ SOLID SURFACE

STEEL

SUBSTRATE

SHEET VINYL

SOLID VINYL TILE

TELEPHONE

TOP OF

TYPICAL

UNLESS NOTED OTHERWISE

VINYL COMPOSITION TILE

VINYL WALL COVERING

WALL COVERING

WALL PROTECTION

WOOD

WELDED SEAM SHEET FLOORING

ACMP

AT

AFF

AL

BATT

BO

CBB

CCW

CFMF

CG

C

CMU

CO

COMM

CONC

SCONC

CONT

COR

CT

CTB

CP

DIA

EJ

ELEC

EQ

ES

ETC

EXIST

EXP

FAC FIN

FD

FEC

FHC

FF

FIN

FLR

FO

FV

FWC

GA

GRA

GYP BD/GWB

HC

HM

HR

HVAC

MATL

MAX

MECH

MFR

MIN

MO

MTL

NIC

NTS

OC

OH

PLS

PL

PT

PR

P

QT

RB

REF

REQ'D

RES-3

RES-W

RO

RF

RPH

SC

SCW

SIM

SP

SS

STL

SUBS

SV

SVT

TELE

TO

TYP

UNO

VCT

VWC

WC

WP

WD

WSF

L

A. THE CONTRACTOR SHALL BE PREPARED TO STOP ANY WORK AND CLEAR UP THE

WORK AREA IF SO ASKED IN MEDICAL SITUATIONS REQURING SUCH ACTION.

B. THE CONTRACTOR SHALL NOT ORDER OR INSTALL ANY MATERIALS OR

EQUIPMENT UNTIL SUBMITTALS FOR SUCH HAVE BEEN APPROVED.

C. ALL TOOLS AND MATERIALS USED IN THIS PROJECT SHALL BE PROPERLY

SECURED AT ALL TIMES BY THE CONTRACTOR TO REDUCE POSSIBILITY OF

ANY OF THESE TOOLS BEING A HAZARD TO PATIENTS, VISITORS, OR

STAFF.

D. THE CONTRACTOR WILL BE RESPONSIBLE FOR ACQUIRING I.D. BADGES FOR

EACH MEMBER OF HIS WORK FORCE. VALID FORMS OF I.D. ARE REQUIRED

TO RECEIVE BADGES. COORDINATE WITH COR.

E. THE CONTRACTOR, AT HIS EXPENSE, WILL BE RESPONSIBLE FOR TRAINING

EACH MEMBER OF HIS WORK FORCE ON VA POLICIES FOR ON-SITE WORK

BEFORE ANY MEMBER WILL BE ALLOWED TO PERFORM WORK ON VA

PREMISES.

F. ABSOLUTELY NO VA TOOLS, MATERIALS, OR EQUIPMENT WILL BE LOANED OR

GIVEN BY THE VA TO ANY MEMBER OF THE CONTRACTOR'S WORK FORCE

AT ANY TIME.

G. ANY SMOKE DETECTORS HAVING ANY POTENTIAL FOR EXPOSURE TO CONSTRUCTION

SMOKE, DUST, AND DEBRIS SHALL BE SUITABLY PROTECTED TO PREVENT ACCIDENTAL

ALARM DURING CONSTRUCTION. ALL SUCH ACTION MUST BE FIRST COORDINATED AND

CLEARED WITH COR AND THE VA SAFETY OFFICER. ALL FUNCTIONAL FIRE ALARM

DEVICES SHALL BE ACTIVE WHENEVER CONTRACTOR'S FORCES ARE NOT PRESENT IN

WORK AREA.

H. THE CONTRACTOR MUST PROVIDE WRITTEN FIRE SAFETY CHECKLIST AT THE

END OF EVERY WORK DAY TO THE COR CERTIFYING THAT ALL WORK AREAS

HAVE BEEN SURVEYED AND FOUND TO BE SECURE, SAFE, AND FREE OF

ANY FLAMMABLE LIQUIDS.

I. CONTRACTOR SHALL COORDINATE ONLY WITH THE COR AND CONTRACTING

OFFICER.

J. SEE SPECIFICATION SECTION 01 00 00 AND 01 35 26 FOR INTERIM LIFE SAFETY MEASURES.

K. ALL FINISH COLORS TO BE SELECTED BY COR/ VA INTERIOR DESIGNER WHERE NOT

OTHERWISE INDICATED. CONTRACTOR SHALL SUBMIT THE COLORS FROM

MANUFACTURER'S FULL RANGE OF COLORS.

L.

M.

PROVIDE 24" x 24" ACCESS PANELS IN HARD CEILINGS WHERE DUCTS AND DAMPERS OR

OTHER PIPES REQUIRE ACCESS AS REQUIRED. COORDINATE EXACT LOCATION W/COR.

THE CONTRACTOR SHALL NOT OPERATE ANY EXISTING VA EQUIPMENT WITHOUT

AUTHORIZATION FROM THE VAMC ENGINEERING SERVICE, UNLESS AN EMERGENCY

SITUATION EXISTS.

CARD READERCR

HIGH-PRESSURE LAMINATEHPL

LUXURY VINYL TILELVT

EDGE OF DECKEOD

DOWNSPOUTDS

CONTROL JOINTCJ

DRINKING FOUNTAINDF

FIRE RETARDANT TREATEDFRT

EXTERIOR INSULATION FINISHING SYSTEMEIFS

WATER RESISTANTWR

ARCHITECTURAL LEGEND

A

GA4

A301

A201

A401

ROOM

NAME

+ 0'-6"

F.E.C.

FIRE EXTINGUISHER CABINET

ROOM NAME AND NUMBER

DOOR NUMBER

KEY NOTE

WINDOW TYPE

PARTITION TYPE

DETAIL CALLOUT

DETAIL NUMBER

SHEET WHERE DETAIL IS DRAWN

SECTION CALLOUT

VERTICAL ELEVATION

COLUMN CENTERLINE DESIGNATION

DEMOLITION KEY NOTE

DETAIL NUMBER

SHEET WHERE DETAIL IS DRAWN

ELEVATION CALLOUT

DETAIL NUMBER

SHEET WHERE DETAIL IS DRAWN

J1

SECTION CUT

HEAD/JAMB/SILL DETAIL NUMBER

EQUIPMENT JSN NUMBERX1045

N. CONTRACTOR SHALL MAINTAIN ALL FIRE-RATED ASSEMBLIES WITHIN THE PROJECT

AREA DURING PERFORMANCE OF THE WORK.

AIR CONDITIONINGAC

CARPET TILECPT

EPOXY FLOORINGEPY

REFLECTED CEILING PLANRCP

SOLID SURFACE MATERIALSSM

ACCESSORY TYPEA

O. CONTRACTOR SHALL PROVIDE AND MAINTAIN ALL REQUIRED EXIT LIGHTING AND

SIGNAGE REQUIRED FOR EGRESS WITHIN AND ADJACENT TO THE PROJECT AREA

DURING PERFORMANCE OF THE WORK.

P. INDICATED EXISTING CONDITIONS ARE BASED UPON LIMITED FIELD INVESTIGATION

AND DID NOT INCLUDE DESTRUCTIVE INVESTIGATION OR TESTING, CONTRACTOR

SHALL VERIFY ALL EXISTING CONDITIONS INCLUDING DIMENSIONS OF THE INSTALLED

CONSTRUCTION PRIOR TO COMMENCING WITH THE WORK. IF DISCREPANCIES ARE

DISCOVERED, THE CONTRACTOR SHALL NOTIFY THE COR FOR INTERPRETATION AND

DIRECTION PRIOR TO PROCEEDING WITH THE WORK.

Q. COORDINATE WORK WITH EQUIPMENT SUPPLIER/ INSTALLER CONTRACTED

SEPARATELY WITH THE GOVERNMENT.

FIRE PROTECTION GENERAL NOTES

1. INSTALLATION TO BE IN ACCORDANCE WITH NFPA 13, INTERNATIONAL BUILDING

CODE, LOCAL REQUIREMENTS AND STATE FIRE MARSHALL REQUIREMENTS.

2. ALL PIPING 1 1/2" AND SMALLER SHALL BE SCHEDULE 40 ASTMO52 BLACK STEEL

WITH THREADED FITTINGS AND SHALL COMPLY WITH ASME SEC. 13-1A. ALL

PIPING 2" AND LARGER SHALL BE SCHEDULE 10 ASTM STANDARD BLACK STEEL

PIPING. PLASTIC PIPING IS UNACCEPTABLE. MINIMUM 1" PIPE SHALL BE 1".

3. FIRE SPRINKLER SYSTEM TO BE TESTED @ 200 P.S.I. FOR A MINIMUM OF (2)-

HOURS OR 50 P.S.I. ABOVE STATIC PRESSURE IN EXCESS OF 150 P.S.I. FOR (2)-

HOURS.

4. HANGERS TO BE IN ACCORDANCE WITH NFPA 13, PARAGRAPH 2-6 AND SHALL

BE U.L. LISTED AND F.M. APPROVED WITH 3/8" MINIMUM ROD DIAMETER.

5. HANGER SHALL BE PROVIDED WHEN ARM-OVER IS OVER (1)-FOOT LONG.

6. SPRINKLER LAYOUT IS BASED ON LIGHT HAZARD OCCUPANCY, 0.15 GPM/S.F.

OVER 1,500 SQUARE FEET WITH A MAXIMUM COVERAGE OF 225 SQUARE FEET

PER HEAD.

7. SPRINKLER HEADS IN FINISHED AREAS TO BE 1/2", 1350 F. AS MANUFACTURED

BY VIKING OR APPROVED EQUAL, QUICK RESPONSE.

8. SPRINKLER HEADS IN AREAS WITHOUT CEILING OR IN COMBUSTIBLE

CONCEALED SPACE TO BE 1/2", 1350 F. BRASS UPRIGHT AS MANUFACTURED BY

VIKING OR APPROVED EQUAL, QUICK RESPONSE.

9. FLUSH ALL PIPES BEFORE SPRINKLER ARE IN STALL PER NFPA 13.

10. THE DESIGN INTENT IS FOR THE FIRE MAIN AND SPRINKLER PIPING TO BE

CONCEALED IN WALLS OR ABOVE CEILING CAVITY.

11. BEFORE ANY CUTTING OR WELDING OPERATIONS ARE STARTED CONTRACTOR

SHALL OBTAIN A PERMIT IN ACCORDANCE WITH NFPA 51B-3.2.

12. VALVES TO BE SUPERVISED IN ACCORDANCE WITH NFPA 13.

13. CONTRACTOR SHALL PROVIDE TO THE OWNER ALL LITERATURE AND

INSTRUCTIONS PROVIDED BY THE MANUFACTURER DESCRIBING DEVISES

INSTALLED, CONTRACTOR SHALL ADHERE TO NFPA 25, STANDARD FOR THE

INSPECTION, TESTING AND MAINTENANCE OF THE WATER-BASE FIRE

PROTECTION SYSTEMS.

14. USE 2120 F. HEADS IN NON-AIR CONDITIONED SPACES.

15. CONTRACTOR SHALL INDICATE TEMPERATURE RATING AND LOCATION OF HIGH-

TEMPERATURE SPRINKLER HEADS.

16. INSTALL SPRINKLER HEAD(S) IN CENTER OF CEILING TILES.

17. EXISTING SPRINKLER HEADS BEING REMOVED SHALL NOT BE REINSTALLED,

INSTALL NEW HEADS ONLY.

18. IN RENOVATION PROJECTS THE SPRINKLER SYSTEM SHALL BE MODIFIED TO

ACCOMMODATE THE NEW LAYOUT OF SPRINKLER HEADS, INSTALL NEW PIPING

AS REQUIRED.

FIRE ALARM GENERAL NOTES

A.

B.

C.

D.

E.

F.

EXISTING SYSTEM PRESERVATION

A.

B.

C.

D.

E.

ACTIVATE FIRE PROTECTION

A.

B.

C.

D.

DISRUPTION TO FIRE ALARM AND SPRINKLER SYSTEMS SHALL BE KEPT TO A MINIMUM

OR AVOIDED.

DELINEATE PHASING OF CONSTRUCTION TO ENSURE THAT INSTALLATION OF NEW

SYSTEMS ARE EXPEDITED, AND EXISTING SYSTEMS ARE KEPT IN SERVICE UNTIL THE

REPLACEMENT SYSTEM IS OPERATIONAL.

IF FIRE PROTECTION SYSTEMS ARE TO BE DISRUPTED, PROCEDURES SHALL BE

INCORPORATED INTO THE DESIGN TO MAINTAIN EQUIVALENT LEVELS OF FIRE

PROTECTION AND PROVIDE FORMAL NOTIFICATION TO THE FACILITY WHILE SYSTEMS

ARE DOWN.

AN ACTIVE SPRINKLER SYSTEM, EITHER TEMPORARY OR PERMANENT, SHALL BE IN

PLACE AND OPERATIONAL.

SMOKE DETECTORS SHOULD NOT BE INSTALLED WHERE CONSTRUCTION DUST IS

PRESENT.

REQUIRE THE USE OF "TEMPORARY CONSTRUCTION CONTAINMENT SYSTEMS" THAT

ARE GASKETED AT THE TOP AND BOTTOM TO CREATE AN AIRTIGHT SEAL WHICH

MEETS OR EXCEEDS ICRA CLASS IV REQUIREMENTS AND EXCEEDS ASTM E-84 CLASS A

STANDARDS FOR FLAME AND SMOKE SPREAD.

EXISTING SPRINKLER PROTECTION SHOULD REMAIN ACTIVE WHERE POSSIBLE.

SCHEDULED IMPAIRMENTS AND THEN RETURNED TO SERVICE.

THE EXISTING FIRE ALARM DETECTION AND NOTIFICATION SHALL REMAIN ACTIVE

WHERE POSSIBLE.

SCHEDULED IMPAIRMENTS AND THEN RETURNED TO SERVICE, POSSIBLY CHANGE

SMOKE DETECTORS TO HEAT DETECTORS FOR DURATION OF CONSTRUCTION.

PROVIDE OPTION TO CHANGE SMOKE DETECTORS TO HEAT DETECTORS DURING

DURATION OF CONSTRUCTION.

FIRE ALARM SYSTEM INSTALLATION SHOULD BE COORDINATED AND PLACED IN

SERVICE PRIOR TO FINAL INSPECTION.

MEANS OF NOTIFICATION REQUIRED THROUGHOUT CONSTRUCTION AREAS (NFPA 241

REQUIREMENT)

TEMPORARY SYSTEM MAY BE DESIRED IF THE NEW SYSTEM CANNOT BE INSTALLED AS

CONSTRUCTION PROGRESS.

ONCE INSTALLED, THE SYSTEM SHOULD BE ON EVEN IF PENDING ACCEPTANCE.

ARCHITECTURAL GENERAL NOTES

A. DIMENSIONS, UNLESS OTHERWISE INDICATED, ARE TO:

• FACE OF EXISTING WALL SURFACE

• FACE OF NEW MASONRY

• FACE OF NEW WALL STUDS

• TOP OF SLAB

• TOP OF MASONRY

• ALIGN NEW WALL WITH EXISTING WHERE NOT OTHERWISE INDICATED.

B. COORDINATE WITH ALL DISCIPLINES DOCUMENTS FOR ADDITIONAL REQUIREMENTS.

COORDINATE OPENINGS IN SLABS, ROOF, AND WALLS. WHERE NEW HOLES IN EXISTING

WALLS AND SLABS ARE CREATED FOR PENETRATIONS, COORDINATE SIZE AND LOCATION.

PATCH HOLES CAUSED BY THE REMOVAL OF EQUIPMENT, PIPING, CONDUIT, DUCT,

GRILLES, ETC. WITH MATERIALS MATCHING EXISTING SLAB OR WALL IN STRUCTURE,

MATERIAL, THICKNESS, ALIGNMENT, GRADES, AND QUALITY.

C. COORDINATE AND PROVIDE GALVANIZED METAL BACKER PLATE OR SOLID FIRE

RETARDANT TREATED WOOD BLOCKING FOR WALL-MOUNTED ITEMS. COORDINATE

LOCATIONS WITH COR FOR GOVERNMENT PROVIDED/CONTRACTOR INSTALLED

EQUIPMENT.

D. `PROVIDE' IS DEFINED AS PROVIDING MATERIALS, DELIVERY, STORAGE, HANDLING,

INSTALLATION, ADJUSTMENT, AND CLEANING FOR THE ITEM INDICATED.

E. SEAL PIPE PENETRATIONS THROUGH SLABS, MASONRY, SMOKE RATED PARTITIONS AND

FIRE-RATED PARTITIONS WITH THE APPROPRIATE FIRESTOP TO MAINTAIN THE RATING OF

THE WALL OR SLAB. SUBMIT CUT SHEETS AND SPECIFICATIONS TO THE COR FOR

APPROVAL PRIOR TO INSTALLATION. PROVIDE UL LISTED ASSEMBLES.

F. SKIM COAT ALL DAMAGED EXISTING WALL SURFACES THAT REQUIRE PAINTING.

G. REMOVE MATERIALS WHICH ARE INDICATED TO BE TURNED OVER TO THE COR SHALL BE

DELIVERED BY THE CONTRACTOR TO A PLACE INDICATED BY THE COR.

H.

I.

REMOVE COMPLETELY ALL MATERIALS AS INDICATED ON THE DRAWINGS AND

AS REQUIRED FOR NEW CONSTRUCTION. EDGES AND FACES OF DEMOLISHED AREAS

HALL BE REPAIRED TO ACCEPT NEAT INSTALLATION OF NEW CONSTRUCTION OR

FINISHES . WHERE EXISTING MATERIALS ARE TO BE REPLACED (WALLS, INSULATION,

FLOORING, ETC.) EXISTING MATERIALS, ADHESIVES, ETC. SHALL BE REMOVED AND

EXPOSED SURFACES SHALL BE PREPARED AS INDICATED OR SPECIFIED PRIOR TO

INSTALLATION OF NEW MATERIALS.

PREVENT DAMAGE TO MATERIALS AND FINISHES TO REMAIN. REPAIR DAMAGES FROM

CONSTRUCTION ACTIVITIES TO EXISTING ITEMS TO REMAIN, AT NO ADDITIONAL COST

WHERE SUCH EXPOSED MATERIALS OR FINISHES TO REMAIN ARE DAMAGED.

FIRE PROTECTION DEMOLITION NOTES

1. THESE NOTE ARE APPLICABLE TO THE FULL SET OF CONTRACT DRAWINGS.

2. EXISTING CONDITIONS ARE TAKEN FROM FILED OBSERVATIONS AND PRIOR

CONSTRUCTION DOCUMENTS WHEN AVAILABLE. THE LOCATIONS SHOWN MUST

BE CONSIDERED APPROXIMATE. OTHER SUCH WORK MAYEXIST, HOWEVER,

LOCATION AND SIZE ARE NOT PRESENTLY KNOW.

3. WHEN EXISTING CONSTRUCTION IS DAMAGED DURING WORK BY THIS

CONTRACTOR, REPAIN AND/OR REPLACE WITH SIMILAR OR LIKE MATERIALS AS

MUCH AS POSSIBLE, SUBJECT TO THE FUND AND ARCHITECTURAL APPORVAL.

4. DISPOSE OF ALL DEMOLITION AND/OR OTHER WASTE MATERIALS CAUSED BY

WORK OF THIS CONTRACTOR. LEGALLY DISPOSE ALL MATERIALS TO A

LOCATION OFF SITE.

5. ALL EXISTING PIPPING TO BE REMAIN SHALL BE RECONNECTED TO ACTIVE

SERVICE PIPING.

6. ALL PIPPING TO BE REMOVED SHALL BE REMOVED BACK TO THE ACTIVE

PIPPING AND CAPPED.

7. ALL PIPPING TO BE REMOVED THAT IS LOCATED WITHIN A WALL TO REMAIN MAY

BE ABANDONED IN PLACE PROVIDING THE PIPPING IS INACTIVE. NO DEAD LEGS

PERMITTED. REMOVE THE INACTIVE PIPPING BACK TO BEHIND THE FINISHED

WALL SURFACE AND CAPPED.

8. PATHCH HOLES IN EXISTING CONSTRUCTION LEFT BY THE REMOVAL OF PIPING

OR EQUIPMENT. MAINTAIN THE FIRE/SMOKE RATING OF THE EXSITING

CONSTRUCTION.

9. DEMOLITION SHALL INCLUDE, BUT NOT LIMITED TO: PIPING, VALVES,

EQUIPMENT, HANGERS, SUPPORTS, SPRINKLER HEADS, AND LEGAL DISPOSAL

OFF SITE.

10. ALL PIPING SYSTEMS THAT PASS THROUGH TE AREA OF WORK, WHICH SERVED

SPACES OUTSIDE OF THE AREA OF WORK, SHALL BE KEPT FULLY OPERABLE

DURING CONSTRUCTION. SHUT DOWN OF THESE PIPING SYSTEMS FOR THE

PUPOSE OF RE-ROUTING AND RECONNECTION SHALL BE SCHEDULED WITH THE

OWNER'S REPRESENTATIVE FIVE WORKING DAYS IN ADVANCE. NEW PIPING

SHALL BE PRE-INSTALLED, TESTED, AND READY FOR CONNECTION INA MANNER

TO ALLOW FOR A PRE-SCEDULED ONE DAY SHUTDOWN.

R. LOCATE EXISTING SLAB REINFORCING(TOP AND BOTTOM) THROUGH NON-

DESTRUCTIVE MEANS PRIOR TO SUBMISSION OF PIPING LAYOUT SHOP DRAWINGS FOR

REVIEW. DO NOT CUT EXISTING REINFORCING(TOP OR BOTTOM) OF SLAB DURING

PENETRATION INSTALLATION. COORDINATE PLUMBING PENETRATIONS WITH

PLUMBING.

J. CONTRACTOR SHALL REMOVE ALL THE EXISTING GYP BOARD TO THE EXISTING STUDS.

METAL STUDS WILL BE RPLACED IF DAMAGED OR REQUIRED DURING CONSTRUCTION.

MOUNTING HEIGHTS

PROVIDE BLOCKING AT ALL WALL MOUNTED EQUIPMENT AND ACCESSORIES.

(NOT ALL ITEMS ARE INCLUDED IN THE WORK)

ACCESSIBILITY REQUIREMENTS

FRONT APPROACHES

HINGE-SIDE APPROACHES

LATCH-SIDE APPROACHES

USE EITHER

OPTION 1 OR

OPTION 2

ALL DOOR ASSEMBLIES SHALL BE CONSTRUCTED TO MEET THE

INDICATED MINIMUM CLEARANCES AS APPLICABLE.

1'-0" IF DOOR HAS BOTH

A CLOSER AND A

LATCH

5' -0

1'-6"

3' -6

4'-6"

4' -0

O P

TI

O

N

5' -0

OPTION 1

3'-0"

O P

TI

O

N

4' -6

OPTION 2

3'-6"

2'-0"

4' -0

2'-0"

3' -6

4' -0

4' -6

W / C

LO

S

E R

4' -0

W / C

LO

S

E R

W /C

LO

S

E R

A N

D L

A

TC

H

ALL WORK SHALL COMPLY WITH FEDERAL ABA,

LOCAL, AND STATE ACCESSIBILITY CODES AND

REQUIREMENTS.

DOOR LOCATIONS

TYPICAL DETAILS

TYP DOOR LOCATION

SEE DOOR SCHEDULE

4"

TYP

TYP. HANDRAIL / CRASH

RAIL ELEVATION

CRASH RAIL

HANDRAIL/WALL

GUARD RETURN

TO WALL @ END

4"4"

1'

2"

BASE AS SCHEDULED

CORNER GUARD

DOOR FRAME

OR OPENING

3' -0

M

A X

4"

1'

2"

4" TO INSIDE

CORNER

3'

4"

4'

" T Y

P 3'

4"

H C

2'

9"

2'

6" 3'

8"

CL

CL

FIRE

EXTINGUISHER

CABINET

MIRROR TYP

DF/EWC

HC

DF/EWC

GARMENT

HOOK

M

IN

3' - 0"MAX

2'

9" M

IN

3'

0" M

A X

-1

1' - 0"3' - 6"

SANITARY

NAPKIN

DISPOSAL

GRAB BAR

TP

DISPENSER

6" 3' - 0"

GRAB BAR

SEAT COVER

DISPENSER

MIRROR

4'

0"

2'

9" M

IN

3'

0" M

A X

1' - 6" 1' - 6"

3'

4" H

C

TYP TOILET ROOM

SHOWER

HEAD

SHOWER

CONTROL

GRAB BAR

RECESSED

SOAP DISH

GRAB BAR

2'

9" M

IN

3'

0" M

A X

3'

4"

2'

9" M

IN

3'

0" M

A X

EQ EQ

7'

0"

2'

9" M

IN

3'

0" M

A X

4'

0" M

A X

EQ EQ

TYP SHOWER

SOAP DISPENSER

PAPER

TOWEL

DISPENSER

3'

5"

3'

6"

SOAP

DISPENSER

2'

3' -0

M

A X

SS

SHELF

6'

6"

POSTURE

MIRROR

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

Date:

Drawing Title:

Approved Project Director

Project Title:

1 2 3 4 5 6 7 8 9

FINAL CONTRACT

SUBMITTAL590 MEANS ST NW

Phase Project Number

Building Number

Drawing NumberLocation

Issue Date CheckedFULLY SPRINKLERED

STAMP

STE. 200

ATLANTA, GA 30318

ARCHITECT/ENGINEER OF RECORDCONSULTANT

A

B

C

D

E

F

U.S. Department of Veterans Affairs

Office of Construction and

Facilities Management

Drawn

1 & 12

SJ/EO/SMTS

573-20-604

GENERAL NOTES, DETAILS,

ABBREVIATIONS AND LEGENDS

RENOVATE COMMON AREA

RESTROOMS

GAINESVILLE, FLORIDA

G002 03-21-2024 smittal Snapshot smittal Image smittal

UP

A

B

C

D

E

F

G

H

J

K

L

M

N

P

R

123478910111213141516

ES

JN

8w

R.4

An

1'

4"

ELEVATOR

GAS

STORAGE

C077A-1

GAS

STORAGE

C077-1

ELEC

C073A-1

ELEC

A026-1

HAC

A025-1

RADIO

ISOTOPE

STORAGE

A020-1

TOILET

A021-1

CT SCAN

A018-1

STORAGE

A015-1

NUCLEAR

MAGNETIC

RESONANCE

A022-1

ELEC

A023A-1

CONTROL

A013-1

CAMERA

IMAGING

A016-1

VEST

A006-1

X-RAY

READING

A002-1LAB

A01-1

OFFICE

A01A-1

OFFICE

D125-1

LAB

D124-1

LAB

D121-1

STORAGE

D120-1

LAB

D117-1CARDIOVASCULAR

RESEARCH

LAB

D116-1

LAB

D112-1

CLEAN

ROOM

D110B-1

AUTOPSY

D095-1

OFFICE

D109-2

BIO-MED.

D111-1

BIO-MED

D110A-1

RESEARCH

COMMON

RESOURCE

D113-1 LAB

D114-1

LAB

D107A-1

HAC

D115-1

ELEC

D116B-1

COUNTING

ROOM

D116A-1

WATER

D119-1

DARK

ROOM

D119A-1

RESEARCH

COMMON

RESOURCE

D122-1

SURGERY

ANIMAL

D123-1

MILLION

VETERANS

PROGRAM

A063-1

OFFICE

A061-1

MICROSCOPE

A062-1

LAB

A003-1

DEXA SCAN

A004-1

RESTROOM

A220A-1

INJECTION

ROOM

A010-1

STER. PROC.

D104-1

LAB

D103-1

LAB

D102-1

STORAGE

D107-1

LAB

D105-1

LAB

D106-1

BREAK

ROOM

A005-1

NUCLEAR

MEDICINE

OFFICE

A011-1

STORAGE

A060B-1

ELECTRON

MICROSCOPE

A060-1

SPD.

STORAGE

A059-1

DATA

A027-1

CREDIT

UNION

A031-1

CREDIT

UNION

A031A-1

BREAK

ROOM

A032-1

WOMENS

LOUNGE

B033-1

STAFF

WOMENS

LOCKER

B055-1

STAFF

WOMENS

TOILET

A056-1

STAFF MENS

TOILET

A057-1

CONFERENCE/CLASSROOM

A030-1

STORAGE

A036B-1

VISITOR

WOMENS

TOILET

B035-1

VISITOR

MENS

TOILET

B034-1

RESEARCH

OFFICE

A024B-1 VEST

A024-1

VOLUNTEER

STORAGE

A024A-1

STORAGE

A029-1

AUDITORIUM

A036-1

OFFICE

B038-1

RECREATION

THERAPIST

OFFICE

B037-1

RECREATION

THERAPIST

OFFICE

B039-1

STORAGE

B039A-1

VEST

CB-6A

STORAGE

B040-1

HAC

B041-1

RETAIL

STORE

B046-1

VENDING

B065-1

SERVICE

ELEVATOR

LOBBY

C067-1

HAC

C069-1

DATA

C070-1

PATIENT

STORAGE

C071-1

CLEAN LINEN

DISTRIBUTION

C080B-1

COMPRESSOR

ROOM

C073-1

SEAMSTRESS

ROOM

C081-1

OFFICE

C083-1

OFFICE

C084-1

LOCKSMITH

C085A-1

REFRIGERATION

SHOP

C085-1

EMS

TRAINING

ROOM

C079-1 DIETICIAN

OFFICE

C068F-1

FREEZER

C059-1

REFRIGERATOR

C058-1

MEAT

FREEZER

C056-1

HAC

C068B-1

MAIN

ELECTRICAL

ROOM

D089-1

ESSENTIAL

SYSTEMS

ROOM

C087-1

ENGINEERING

PAINT SHOP

C086-1

STORAGE

C086B-1

SPS

SECRETARY

D092-1

ELEC

D093A-1

WOMENS

STAFF

TOILET

D093-1

MENS STAFF

TOILET

D094-1

FOREMAN

C068D-1

OFFICE

C064-1

OFFICE

B0491-1

B0468-1

CANTEEN

B049-1

VEGETABLE

PREPARATION

C068A-1

ELEC

B054G-1

OFFICE

B054C-1

STORAGE

B054A-1

MAIN

KITCHEN

C068-1OFFICE

C068E-1

STORAGE

C076-1

REFRIGERATOR

C060-1

ELEVATOR A

CB-9

SOILED

LINEN

D072-1

OFFICES

D100A-1

LAB

D101A-1

CLINICAL

RESEARCH

ELE. TECH

LAB

D101-1

ELECTRIC

SHOP

C086A-1

MACHINE

ROOM

C080C-1

OFFICE

C080A-1

HAC

D100U-1

RECEIVING

DECONTAMINATION

D100E-1

HAC

D100K-1

CART WASH

D100D-1

STERILIZATION

ROOM

D100L-1

HAC

D100R-1

MENS

TOILET

D100Q-1

WOMENS

TOILET

D100P-1

OFFICE

D099-1

CHIEF

D099A-1

OFFICE

D099B-1

CLEAN

RECEIVING

AREA

D100M-1

PREPARATION

AREA

D100N-1

SUPPLY

PROCESSING

AND

DISTRIBUTION

D100-1

SHOWER

D100G-1

TOILET

D100H-1

VEST

D100F-1

AUTOPSY

SUPPLY

D095A-1

TOILET

D095B-1

OFFICE

D108A-1

RESEARCH

INVESTIGATOR

D108-1

COLD ROOM

D095C-1

COMMON

RESEARCH

D096-1

LAB

D123A-1

LAB

A062A-1

STORAGE

D091-1

FILM

STORAGE

C080D-1

OFFICE

A060A-1

STORAGE

A026C-1

CREDIT

UNION

A031B-1

STORAGE

A036C-1

VENDING

B065A-1

DIET. TECH.

B050C-1

CORRIDOR

xxx

DIET SECY.

B050-1

CHIEF

DIETETICS

OFFICE

B050A-1

SOCIAL

WORK

B032A-1

VACANT

OFFICE

A030C-1

STORAGE

B054E-1

OFFICE

B054B-1

CLASSROOM

B054F-1

COFFEE

SHOP

B049J-1

NUTRIENT &

FOOD

SERVICES

C068C-1

DAIRY

REFRIGERATOR

C057-1

VEGETABLE

FREEZER

C055-1

STORAGE

B054D-1

FOOD STOCK

ROOM

B049H-1

FOOD

PREPARATION

AREA

B049C-1

CORRIDOR

A156-205

CORRIDOR

A156-206

RETAIL

RECEIVING

SECURE

STORAGE

B0498-1

OFFICE

B046D-1

OFFICE

B049E-1

STOCKROOM

B047-1

OFFICE

D114A-1

STORAGE

D100O-1

MECH

D100B-1

EQUIPMENT

SPD

D100C-1

SCANNER

ROOM

A019-1

CONTROL

A017-1

CONTROL

A014-1

CLOSET

EB52A-1

STAFF MENS

LOCKERS

A058A-1

STER. PROC.

SOILED

SCOPE

D104A-1

TOILET

A017A-1

WAITING

A012-1

DINING

ROOM

B049F-1

FEC

B-4-1

FEC

B-7-1

ELEC

C068H-1

FEC

B-9-1

DISH

WASHING

C480-1

DATA

C068G-1

PATIENTS

DINING

ROOM

B054-1

FEC

B-6-1

FEC

B-11-1

STORAGE

B048-1

STAGE

A036A-1

FEC

B-5-1

CLOSET

A024C-1

CLOSET

A024D-1

DATA

A026B-1

DATA

A026A-1

LOUNGE

A058-1

MECH

A059A-1

TRAYV.

D1001-1

LAUNDRY

SHOOT

D072A-1

ANTE ROOM

D100T-1

OFFICE

C086C-1

DATA

D098-1

STORAGE

D098A-1

FEC

B-14-1

FEC

B-13-1

CLOSET

A019A-1

CT SCAN

A023-1

EXAM

A009-1

FEC

B-2-1

STORAGE

D109A-1

ELEVATOR

D109-3

ELEVATOR

D109-4

ELEVATOR

D109-5

ELEVATOR

D109-6

ELEVATOR

D109-7

ELEVATOR

D109-8

STAIR

3-0

STAIR

2-0

STAIR

1-0STAIR

4-0

OFFICE

A006B-1

CHIEF

TECHNOLOGIST

A006A-1

OFFICE

A006C-1

LACTATION

ROOM

B055A-1

OFFICE

B050B-1

SPS NURSE

D092A-1

OFFICE

C080E-1

CORRIDOR

C080F-1

OFFICE

C080-1

ELEC

D109-9

ELEC

D109-10

MECH

B049K

CARBINATION

STORAGE

D109-11

TRANSFORMER

ROOM

C126-1

SWITCHGEAR

ROOM

C126A-1

TLT

D109-16

OFFICE

D109-15

BOILER

ROOM

D109-14

STORAGE

C078F-1

GRAPHICS

CONTROL

C078E-1

AIR

CONDITIONING

EQUIPMENT

CONTROL

ROOM

C078-1

MECH

C078D-1

LOCKER

ROOM &

BATH

C078G-1

CORRIDOR

D109-17

TYP

6 5

TYP

TYP

D A

C B

EF

G

KEY PLAN

TRUE

NORTH

PLAN

NORTH

DEMO PLAN GENERAL NOTES

A. CONTRACTOR SHALL GUT AND REMOVE ALL EXISTING CONSTRUCTION DOWN TO EXISTING STUDS/ STRUCTURE REQUIRED TO INSTALL NEW WORK AND SHALL DISPOSE OF ALL DEMOLISHED MATERIALS IN

AN APPROVED, OFFSITE LANDFILL EXCEPT WHERE OTHERWISE REQUIRED FOR SALVAGE OR

RECYCLING.

B. CONTRACTOR SHALL DEMOLISH ALL EXISTING MILLWORK, TOILET ACCESSORIES, GRAB BARS, COUNTERTOPS, AND TOILET PARTITIONS IN AREA OF WORK.

C. REFER TO AND COORDINATE WITH OTHER DICSIPINES DRAWINGS AND DOCUMENTS FOR ADDITIONAL

INFORMATION AND INSTRUCTIONS.

D. REMOVE AND STORE EXISTING SIGNAGE FOR REINSTALLATION.

E. DEMOLISH EXISTING FLOORING & BASE INCLUDING FLOORING UNDERLAYMENT IN AREA OF WORK AS

NEEDED TO INSTALL NEW WORK.

EXISTING DOOR, HARDWARE AND FRAME ASSEMBLY TO REMAIN. PREPARE SURFACE FOR NEW FINISH.

DEMO FLOOR PLAN KEY NOTES #

2 DEMOLISH EXISTING LOCKERS AND BENCHES.

3 DEMOLISH EXISTING WALL & FLOOR EXPANSION JOINT COVER IN AREA OF WORK AS INDICATED.

4 DEMOLISH EXISTING DOOR, FRAME ASSEMBLY AND HARDWARE AS INDICATED.

5 REMOVE EXISTING EQUIPMENT, RELOCATE AND STORE AT A APPROVED LOCATION FOR

REINSTALLATION.

DEMO PLAN LEGEND

EXISTING CONSTRUCTION

TO REMAIN

EXISTING CONSTRUCTION TO BE

DEMOLISHED

2-HOUR FIRE BARRIER

1-HOUR FIRE BARRIER

AREA OF WORK

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

Date:

Drawing Title:

Approved Project Director

Project Title:

1 2 3 4 5 6 7 8 9

FINAL CONTRACT

SUBMITTAL590 MEANS ST NW

Phase Project Number

Building Number

Drawing NumberLocation

Issue Date CheckedFULLY SPRINKLERED

STAMP

STE. 200

ATLANTA, GA 30318

ARCHITECT/ENGINEER OF RECORDCONSULTANT

A

B

C

D

E

F

U.S. Department of Veterans Affairs

Office of Construction and

Facilities Management

Drawn

1 & 12

SJ/EO/SMTS

573-20-604

OVERALL BASEMENT DEMO PLAN -

AREA A, B, C & D

RENOVATE COMMON AREA

RESTROOMS

GAINESVILLE, FLORIDA

AD101

03-21-2024

1/16" = 1'-0"AD101

1 OVERALL BASEMENT DEMO PLAN - AREA A,B,C &D

SCALE:

0' 8' 16' 32' 48'

1/16" = 1' - 0" smittal Snapshot smittal Image smittal

B

C

D

E

F

G

H

J

K

L

25 24 23 22 21.2 20 19 18 17 16

D1

E1

K5

M

20.221.4

15 14

2710 SF

UPPER

MECHANICAL

ROOM

EB60-1

85 SF

OFFICE

EB62A-1

45 SF

FIRE ALARM

CLOSET

EB62-1

40 SF

ELEC

EB61-1

178 SF

ASST. CHIEF

HIMS

EB58-1

132 SF

OFFICE

EB56A-1

683 SF

VAVS &

STORAGE

EB55-1

456 SF

RELEASE OF

INFORMATION

EB54-1

238 SF

CHIEF HIMS

EB57B-1

88 SF

OFFICE

EB53-1

76 SF

OFFICE

EB54A-1

90 SF

OFFICE

EB52-1

275 SF

OFFICE

EB51-1

304 SF

OFFICE

EB32-1

166 SF

OFFICE

EB32B-1

84 SF

HAC

EB01-1

180 SF

MAIL ROOM

EB02-1

56 SF

FLAMMABLE

STORAGE

EB64-1

54 SF

FLAMMABLE

STORAGE

EB63-1

104 SF

MENS

TOILET

EB03-1

100 SF

WOMENS

TOILET

EB04-1

113 SF

OFFICE

EB06-1

101 SF

OFFICE

EB07-1

136 SF

OFFICE

EB09-1

22 SF

HAC

EB11-1

103 SF

OFFICE

EB12-1

104 SF

EXAM

EB14-1

21 SF

SOILED

STORAGE

EB16A-1

114 SF

WORK ROOM

EB13-1

319 SF

RECEPTION

EB18A-1

122 SF

EXAM

EB25-1

123 SF

EXAM

EB20-1

141 SF

OFFICE

EB19-1

42 SF

ELEC

EB08-1

184 SF

AUDIOLOGY

EXAM ROOM

EB26-1

90 SF

LOUNGE

EB27-1

202 SF

STAIR

6-B-1

92 SF

SPEECH

PATHOLOGY

OFFICE

EB34-1

92 SF

CHIEF

AUDIOLOGY

EB33-1

25 SF

HAC

EB35-1

28 SF

ELEC

EB47-1

99 SF

MENS

TOILET

EB46-1

93 SF

WOMENS

TOILET

EB45-1

127 SF

SPEECH

LANGUAGE

PATHOLOGIST

EB44-1

79 SF

APHASIA

EB43-1

101 SF

EXAM

EB42-1

74 SF

SPEECH

PATHOLOGY

OFFICE

EB41-1

147 SF

RECEPTION

EB36A-1

98 SF

OFFICE

EB37-1

193 SF

EXAM

EB40-1

115 SF

GROUP

THERAPY

EB39-1

76 SF

OFFICE

EB38-1

169 SF

TREATMENT

EB24-1

107 SF

EXAM

EB16-1

148 SF

TREATMENT

EB15-1

147 SF

SOUND TEST

EXAM

EB36E-1

156 SF

OFFICE

EB28-1

70 SF

UTLILTY

CLOSET

EB05-1

357 SF

WAITING

EB36-1

360 SF

STORAGE

EB81-1

302 SF

LAB

EB71-1

566 SF

STORAGE

EB67-1

790 SF

UPPER

TRANSFORMER

ROOM

EB66-1

498 SF

UPPER

GENERATOR

ROOM

EB65-1

255 SF

STAIR

7-1

9 SF

DATA

EB32A-1

618 SF

CORRIDOR

E213-70

369 SF

CORRIDOR

E213-71

458 SF

CORRIDOR

E213-72

623 SF

CORRIDOR

E213-73

193 SF

ELEVATOR B

E213-74

154 SF

CORRIDOR

E213-75

1688 SF

CORRIDOR

782 SF

CORRIDOR

EB68-1

42 SF

STORAGE

EB67B-1

78 SF

ELEVATOR

79 SF

ELEVATOR

76 SF

ELEVATOR

70 SF

ELEVATOR

1442 SF

PHARMACY

STORAGE

EB59D-1

472 SF

CONFERENCE

ROOM

EB91-1

455 SF

CLASSROOM

EB59B-1

784 SF

STORAGE

EB84-1

91 SF

SUPPLY

GENERAL

ENGI.

EB86-1

110 SF

TOILET

EB94-1

109 SF

TOILET

EB95-1

173 SF

COPY ROOM

EB93-1

113 SF

OFFICE

EB59G-1

87 SF

OFFICE

EB59F-1

98 SF

ARCHITECT

EB59E-1 1258 SF

ENGINEERING

EB59-1

92 SF

INDUSTRIAL

HYGENIST

EB59H-1

99 SF

OFFICE

EB59I-1

162 SF

VACANT

EB59A-1

125 SF

ENGIN. TECH

#4

EB59C-1

113 SF

ENGIN. TECH

#3

EB96-1

117 SF

ENGIN. TECH

#2

EB92-1

108 SF

ENGIN. TECH

#1

EB90-1

98 SF

SUPER.

GENERAL

ENGINEER

EB89-1

124 SF

ACCT. TECH.

EB88-1

117 SF

RECEPTION

EB105-1

136 SF

RECEPTION

EB103-1

108 SF

DIVISION

CHIEF

EB101-1

118 SF

ENERGY

ENGINEER

EB99-1

114 SF

SAFETY

OFFICER

EB97-1

145 SF

TRANSPORTATION

COORDINATOR

EB98-1

152 SF

SAFETY

SPECIALIST

EB100-1

109 SF

KITCHEN

EB102-1

159 SF

SYSTEM

CHIEF

ENGIN.

SERV.

EB104-1

371 SF

CONFERENCE

ROOM

EB106-1

610 SF

CARPENTER

EB29-1

107 SF

EXAM

EB17-1

111 SF

EXAM

EB23-1

17 SF

STORAGE

EB10-1

30 SF

CLEAN

STORAGE

EB16B-1

110 SF

NURSE

STATION

EB21-1

98 SF

OFFICE

EB38A-1

53 SF

SOUND

ROOM

EXAM

EB360-1

50 SF

SOUND

ROOM EXAM

EB36F-1

97 SF

EXAM

EB39A-4

123 SF

EXAM

EB76-1

145 SF

SOUND

ROOM EXAM

EB36C-1

60 SF

OFFICE

EB73-1

90 SF

OFFICE

EB72-1

88 SF

OFFICE

EB70-1

63 SF

OFFICE

EB69-1

299 SF

LAB

222 SF

CORRIDOR

EB36B-1

116 SF

EXAM

EB75-1

126 SF

EXAM

EB74A-1

284 SF

OFFICE

EB77-1

178 SF

CONFERENCE

ROOM

EB79-1

107 SF

COLD ROOM

EB82-1

53 SF

TOILET

EB78-1

91 SF

CLEAN

ROOM

EB80B-1

730 SF

BIO-MED.

SHOP

EB80-1

97 SF

OFFICE

EB80A-1

81 SF

DATA

EB80C-1

157 SF

OFFICE

EB55B-1

139 SF

OFFICE

EB55A-1

130 SF

BREAK

ROOM

EB55C-1

155 SF

OFFICE

EB56-1

85 SF

OFFICE

EB62B-1

174 SF

OFFICE

EB55D-1

227 SF

EB01A-1

61 SF

FILES

EB29B-1

72 SF

STORAGE

EB29A-1

121 SF

OFFICE

EB51A-1

135 SF

OFFICE

EB49-1

59 SF

TRAVEL

OFFICE

44 SF

DATA

EB57A-1

125 SF

OFFICE

EB57-1

158 SF

STORAGE

EB85-1

155 SF

EB67A-1

212 SF

STAIR

5-1

135 SF

CORRIDOR

6 SF

CLOSET

EB23A-1

156 SF

EXAM

EB74-1

49 SF

ELEVATOR B

TRUE

NORTH

PLAN

NORTH

D A

C B

EF

G

DEMO GENERAL NOTES

A. CONTRACTOR SHALL GUT AND REMOVE ALL EXISTING CONSTRUCTION DOWN TO EXISTING STUDS/ STRUCTURE REQUIRED TO INSTALL NEW WORK AND SHALL DISPOSE OF ALL DEMOLISHED MATERIALS IN

AN APPROVED, OFFSITE LANDFILL EXCEPT WHERE OTHERWISE REQUIRED FOR SALVAGE OR

RECYCLING.

B. CONTRACTOR SHALL DEMOLISH ALL EXISTING MILLWORK, TOILET ACCESSORIES, GRAB BARS, COUNTERTOPS, AND TOILET PARTITIONS IN AREA OF WORK.

C. REFER TO AND COORDINATE WITH OTHER DICSIPINES DRAWINGS AND DOCUMENTS FOR ADDITIONAL

INFORMATION AND INSTRUCTIONS.

D. REMOVE AND STORE EXISTING SIGNAGE FOR REINSTALLATION.

E. DEMOLISH EXISTING FLOORING & BASE INCLUDING FLOORING UNDERLAYMENT IN AREA OF WORK AS

NEEDED TO INSTALL NEW WORK.

DEMO FLOOR PLAN KEY NOTES #

1 EXISTING DOOR, HARDWARE AND FRAME ASSEMBLY TO REMAIN. PREPARE SURFACE FOR NEW FINISH.

0' 4' 8' 16' 24'

SCALE: 3/32" = 1'-0"

32'

DEMO PLAN LEGEND

EXISTING CONSTRUCTION

TO REMAIN

EXISTING CONSTRUCTION TO BE

DEMOLISHED

2-HOUR FIRE BARRIER

1-HOUR FIRE BARRIER

AREA OF WORK

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

Date:

Drawing Title:

Approved Project Director

Project Title:

1 2 3 4 5 6 7 8 9

FINAL CONTRACT

SUMBITTAL590 MEANS ST NW

Phase Project Number

Building Number

Drawing NumberLocation

Issue Date CheckedFULLY SPRINKLERED

STAMP

STE. 200

ATLANTA, GA 30318

ARCHITECT/ENGINEER OF RECORDCONSULTANT

A

B

C

D

E

F

U.S. Department of Veterans Affairs

Office of Construction and

Facilities Management

Drawn

1 & 12

SJ/EO/SMTS

573-20-604

OVERALL BASEMENT DEMO PLAN -

AREA E

RENOVATE COMMON AREA

RESTROOMS

GAINESVILLE, FLORIDA

AD102

03-21-2024

3/32" = 1'-0"AD102

1 OVERALL BASEMENT PLAN - AREA E

KEY PLAN E

smittal Snapshot smittal Image smittal

26272829303132

B.2

C.2

D.2

E.2

E.7

F.5

G.7

J

K.3

M

M.6

N

E.8 j k l

ELEVATOR

S-12

ELEVATOR

S-11

REC. REV

FB23A-1

MAS

RECORDS/WK

AREA

FB23-1

FAC./BODY

STUDIO

FB11-1

ORTHO LAB

FB09-1

OFFICE

FB07-1

CORRIDOR

F-CB-4

OFFICE

FB08-1

OFFICE

FB16-1

OFFICE

FB16A-1

HAC

FB13-1

DATA

FB14-1

CORRIDOR

F-CB-6

CORRIDOR

F-CB-3

BRAIN

REHAB

RESEARCH

DEPARTMENT

FB06-1

OFFICE

FB05-1

MENS

TOILET

FB03C-1

MENS

LOCKER

ROOM

FB03B-1

VEST

FB03A-1

WOMENS

TOILET

FB02C-1

WOMENS

SHOWER

FB02D-1

WOMENS

LOCKER

ROOM

FB02B-1

VEST

FB02A-1

LOUNGE

FB01-1

HAC

FB04-1

STAIR

7-1

EXIT

CORRIDOR

F-CB-1

DISPENSING

FB15-1APPL.

STOR./MAILOUT

FB17-1

ELEVATOR

FB00-1

TOILET

FB18A-1

ELEC

FB20-1

STORAGE

FB21-1

STORAGE

FB22-1

ELEVATOR

LOBBY

F-CB-8

EXIT

CORRIDOR

F-CB-9

SUPERVISOR

FB25-1

PATIENT

LUGGAGE

FB24-1

COPY ROOM

FB27-1

HAC

FB28A-1

FENCED

STORAGE

FB28D-1

GENERAL

BUILDING

STORAGE

FB26-1

EXIT

CORRIDOR

WAREHOUSE

FB28-1

ELEC

FB30-1

DATA

FB28K-1

ELEC

FB28J-1

FLAMMABLE

GAS

FB31-1

MEDICAL

GAS

FB32-1

MEDICAL

GAS

FB33-1

WOMENS

TOILET

FB28H-1

MENS

TOILET

FB28G-1

DOCK

WAREHOUSE

SUPERVISOR

FB28F-1

MAIL

CENTER

SUPERVISOR

FB28E-1

STAIR

8-1

OFFICE

FB08A-1

TREATMENT

ROOM

FB18-1

EXAM

FB18B-1

DATA

FB05B-1

OFFICE

FB05C-1

OFFICE

FB05A-1

OFFICE

FB05D-1

COOLERS

FB28B-1

COOLERS

FB28C-1

MENS

SHOWER

FB03D-1

UPPER

MECHANICAL

ROOM

FB29-1

FILE

STORAGE

FB17A-1

OFFICE

GC129-2

Room

GC129-3

Room

GC129-4

OFFICE

GC129-5

BREAK

ROOM

GC129-7

TYP

TYP

D A

C B

EF

G

TRUE

NORTH

PLAN

NORTH

DEMO GENERAL NOTES

A. CONTRACTOR SHALL GUT AND REMOVE ALL EXISTING CONSTRUCTION DOWN TO EXISTING STUDS/ STRUCTURE REQUIRED TO INSTALL NEW WORK AND SHALL DISPOSE OF ALL DEMOLISHED MATERIALS IN

AN APPROVED, OFFSITE LANDFILL EXCEPT WHERE OTHERWISE REQUIRED FOR SALVAGE OR

RECYCLING.

B. CONTRACTOR SHALL DEMOLISH ALL EXISTING MILLWORK, TOILET ACCESSORIES, GRAB BARS, COUNTERTOPS, AND TOILET PARTITIONS IN AREA OF WORK.

C. REFER TO AND COORDINATE WITH OTHER DICSIPINES DRAWINGS AND DOCUMENTS FOR ADDITIONAL

INFORMATION AND INSTRUCTIONS.

D. REMOVE AND STORE EXISTING SIGNAGE FOR REINSTALLATION.

E. DEMOLISH EXISTING FLOORING & BASE INCLUDING FLOORING UNDERLAYMENT IN AREA OF WORK AS

NEEDED TO INSTALL NEW WORK.

EXISTING DOOR, HARDWARE AND FRAME ASSEMBLY TO REMAIN. PREPARE SURFACE FOR NEW FINISH.

DEMO FLOOR PLAN KEY NOTES #

2 DEMOLISH EXISTING LOCKERS AND BENCHES.

0' 4' 8' 16' 24'

SCALE: 3/32" = 1'-0"

32'

DEMO PLAN LEGEND

EXISTING CONSTRUCTION

TO REMAIN

EXISTING CONSTRUCTION TO BE

DEMOLISHED

2-HOUR FIRE BARRIER

1-HOUR FIRE BARRIER

AREA OF WORK

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

Date:

Drawing Title:

Approved Project Director

Project Title:

1 2 3 4 5 6 7 8 9

FINAL CONTRACT

SUBMITTAL590 MEANS ST NW

Phase Project Number

Building Number

Drawing NumberLocation

Issue Date CheckedFULLY SPRINKLERED

STAMP

STE. 200

ATLANTA, GA 30318

ARCHITECT/ENGINEER OF RECORDCONSULTANT

A

B

C

D

E

F

U.S. Department of Veterans Affairs

Office of Construction and

Facilities Management

Drawn

1 & 12

SJ/EO/SMTS

573-20-604

OVERALL BASEMENT DEMO PLAN -

AREA F & G

RENOVATE COMMON AREA

RESTROOMS

GAINESVILLE, FLORIDA

AD103

03-21-2024

3/32" = 1'-0"AD103

1 OVERALL BASEMENT DEMO PLAN - AREA F&G

smittal Snapshot smittal Image smittal

UP

A

B

C

D

E

F

G

H

J

K

L

M

N

P

R

123478910111213141516

ES

JN

2W8w

Ms

R.4

An

OFFICE

A164L-1

OFFICE

A164I-1

OFFICE

A164G-1

OFFICE

A164H-1

CONTROLLED

SUBSTANCE

VAULT

A165-1

MECH.

EQUIP. RM.

C298-1

CARDIAC

OPERATING

ROOM - C

C277-1

OPERATING

ROOM - D

C278-1

SOILED

UTILITY

C279-1

STORAGE

C282A-1

DEVELOPING

ROOM

C282-1

OPERATING

ROOM - B

C289-1

SOILED

HOLDING

C288-1

OPERATING

ROOM - A

C287-1

STORAGE

C282E-1

SCRUB

ROOM

C282D-1

CENTRAL

CORE

HAC

C284-1

MEN

LOCKERS

C283-1

MENS

TOILET

C283A-1

WOMENS

TOILET

C281-1

OFFICE

C268-1

OFFICE

C267-1

OFFICE

C258-1

OFFICE

C257-1

OFFICE

C269-1

OFFICE

C270-1

OFFICE

C251-1

BREAK

ROOM

C250-1

RECEPTION

C271-1

BLOOD

GAS LAB.

C248-1

OFFICE

C274-1

CATH LAB.

C254-1

TOILET

C252-1

CONTROL

ROOM

C254A-1

ELEC

STORAGE

C256-1

CATH. LAB

C255-1

OFFICE

C260-1

OFFICE

C259A-1

OFFICE

C259-1

X-RAY

CONSULTS

C295-1TOILET

C294A-1

X-RAY

ROOM 8

C294-1OFFICE

C297-1

X-RAY

D301-1

ELEC

D311A-1

CHEST

X-RAY

D308-1

FILM

STORAGE

D337-1

X-RAY

DIAGNOSTIC

VII

D300-1

CONTROL

D305A-1

X-RAY

DIAGNOSTIC

I

D305-1

STORAGE

D306-1

TOILET/

STORAGE

D304-1

TOILET

D304A-1

CENTRAL

HAC

B183-1

DOCTOR

B202-1

RECEPTION

B206-1

HAC

B207-1OFFICE

B181-1

STORAGE

B206A-1

OFFICE

B205-1

OFFICE

B204-1

OFFICE

B203-1

OFFICE

B200-1

RECEPTION

B199-1

STORAGE

B222B-1

STORAGE

B222A-1

WHIRLPOOL

TANK RM

B216-1

CHIEF O.T.

B220-1

P.T.

TREATMENT

ROOM

B222-1

PHYSICAL

THERAPY

B221-1

CORRECTIVE

THERAPY

B235-1

OFFICE

B235A-1

ELEC

CHAPLAIN

SERVICE

B229-1

EUCHARISTIC

B228-1

ADMIN

OFFICER

B217-1

EMG. LAB.

B223-1

HAC

B224-1

ADL ROOM

B226-1

MENS

TOILET

B234-1

WOMENS

TOILET

B233-1

OFFICE

B232-1

OFFICE

B231-1

CHAPEL

B230-1

OT WORK

ROOM

B219-1

REHAB. MED.

RECEPTION

B218-1

STAFF

PSYCHIATRIST

B214-1

STORAGE

A125A-1

OFFICE

B139B-1

GENERAL

/SURGERY

RECEPTION

B139-1

OFFICE

B138A-1

OFFICE

A140A-1

SURGERY

OFFICE

A140-1

CONFERENCE

ROOM

B209-1

WAITING

B208-1OFFICE

B144-1

SOCIAL

WORKER

B190-1

OFFICE

B142-1

SERVICE

LOBBY

TRASH

C262-1

SURGICAL

PATHOLOGY

C264-1

OFFICE

C285A-1

CYSTO 1

C265A-1

GENITO

URINARY

CLINIC

C197-1

CYSTO 1

C198-1

TOILET

C199-1

CLERKS

STATION

C265-1

SUPPLY

D335A-1

OFFICE

D363A-1

X-RAY

C203-1

EXAM

C204-1

STORAGE

D169-1

SOILED

UTILITY

D171-1

EXAM 9

D168-1

WOMENS

TOILET

A145-1

MENS

TOILET

A144-1

OFFICE

A147-1

PARALYZED

VET OF

AMERICA

A141-1

OFFICE

WOMENS

TOILET

A127-1

MENS

TOILET

A126-1

OFFICE

A129-1

OFFICE

A130-1

OFFICE

A133-1

OFFICE

A134A-1

EXECUTIVE

CONFERENCE

& M.I.C.

A125-1

HAC

A123-1

CHIEF OF

STAFF

A124-1

ADMIN ASST

A117-1

RECEPTION

A116A-1

QUI COORD

A115-1

OFFICE

A119-1

OFFICE

A120-1

OFFICE

A122-1

ASSOCIATE

DIRECTOR

A112-1

COPY FILES

A114-1

OFFICE

A107A-1

TOILET

A112C-1

HOSPITAL

DIRECTOR

A111-1

RECEPTION

A109-1

RECEPTION

A108-1

OFFICE

A106-1

OFFICE

A105-1

OFFICE

A107-1

OFFICE

A104-1

RECEPTION

A102-1

OFFICE

A101-1

MENS

TOILET

A160-1

WOMENS

TOILET

A159-1

EXAM 7

D371-1

FDVA OFFICE

D162-1

FDVA OFFICE

D163-1

ELEC

D166-1

OFFICE

D370A-1

OFFICE

D361-1

EXAM 8

OFFICE

D326A-1

OFFICE

D326B-1

OFFICE

D326C-1

STAFF ONLY

D352-1

OFFICE

D353-1

OFFICE

D355A-1

EXAM 1

D350-1

EXAM 2

D347-1

EXAM 3

D346-1

EXAM 4

D355B-1

EXAM 5

D358-1

OFFICE

D357-1

OFFICE

D355C-1

OFFICE

D355-1

OFFICE

D356-1

WAITING

D336-1

CLOSET

A111A-1

CLOSET

A112A-1

ELEC

A116B-1

OFFICE

A121-1

WOMENS

WET

BATHROOM

B215-1

OCCUPATIONAL

THERAPY

OFFICE

OFFICE

OFFICE

A114C-1

CONFERENCE

ROOM

A128-1

ASSISTANT

CHIEF

A151-1

CHIEF

A152-1

OFFICE

A153-1

OFFICE

A155-1

CONFERENCE

ROOM

A154-1

STERILE

PREP.

A164B-1

OFFICE

D323A-1

OFFICE

D324B-1

OFFICE

D324C-1

MENS

TOILET

D320-1

WOMENS

TOILET

D319-1

LOUNGE

D321-1

MICROSCOPE

ROOM

D325-1

PATHOLOGY

D329-1

CLERICAL

AUTOPSY/

PATHOLOGY

D318-1

STORAGE

D315-1

OFFICE

D316-1

OFFICE

D333-1

FLOW

CYTOMETRY

D314-1

MICROBIOLOGY

LAB

D334-1

WOMENS

TOILET

D311-1

MENS

TOILET

D310-1

BACTERIOLOGY

D312-1

RESTROOM

D351-1

HISTOLOGY

D341A-1

CYTOLOGY

D341B-1

SURGICAL

PATHOLOGY

LAB.

D340-1

CYTOLOGY

D339-1

HISTOLOGY

D341C-1

WORK ROOM

EXAM 6

D344-1

TOILET

D307B-1

EXAM

C317-1

TOILET

C318-1

LAB

D375-1

OFFICE

D376-1

CONSULT

D161B-1

OFFICE

D374-1

STORAGE

D373-1

PARALYZED

VET. OF

AMERICA

D161A-1

FDVA OFFICE

D161-1

WORK/LOUNGE

D372-1

X-RAY

D307-1

BIOMED

WORKSHOP

D366F-1

OFFICE

D343-1

OFFICE

OFFICE

D331-1

OFFICE

D332-1

OFFICE

RAD.

OFFICES

FILE ROOM

D337A-1

ISOLATION

C286B-1

SOILED

UTILITY

C286A-1

OFFICE

EXAM

C340-1

OFFICE

D363B-1

EXAM 2

D170-1

CLEAN

UTILITY

D167-1

EXAM

C344-1

OFFICE

C345-1

EXAM

C346-1

EXAM

C347-1

EXAM

C348-1

EXAM

C349-1

STORAGE

C263-1

DATA

C263A-1

BED 6

ISOLATION

C244A-1

BED 7

ISOLATION

C244B-1

BED 8

ISOLATION

C244C-1

LINEN

C244D-1

SICU

C244-1

OFFICE

C244F-1

CATH LAB

C246A-1

DARK ROOM

WORK ROOM

C244H-1

LOUNGE

C244G-1

BIO. HAZARD

STORAGE

C242-1

TOILET

C243A-1

KITCHEN

C243-1

COMPUTER

ROOM

C246C-1

CONTROL

ROOM

C246B-1

SPD

STORAGE

B189-1

STORAGE

B188A-1

SOILED

UTILITY

BED 5

ISOLATION

B193-1

BED 6

ISOLATION

B192-1

STORAGE

B195-1

OFFICE

B194-1

LOCKERS

B184-1

LOUNGE

B185B-1

CHARTING

B188C-1

ON-CALL

B187-1

LINEN

B186-1

TOILET

B185A-1

LOCKERS

B185C-1

TOILET

B187A-1

CCU & SICU

STORAGE.

B383-1

OFFICE

B182C-1

OFFICE

B198-1

OFFICE

B201-1

SURGICAL

ADMIN

B182A-1

OFFICE

B182B-1

OFFICE

B181D-1

OFFICE

B235B-1

CHIEF

SECURITY

B141A-1

RECEPTION

B141-1

OFFICE

B138B-1

OFFICE

B139A-1

OFFICE

B137C-1 RECEPTION

B137-1

CHIEF OF

SURGERY

B137A-1

RECEPTION

B138-1

OFFICE

A132A-1

DATA

A132-1

OFFICE

A134-1

INPATIENT

PHARMACY

A164-1

RESEARCH

A164E-1

OFFICE

A164D-1

OFFICE

LOUNGE

A103A-1 BREAK

ROOM

A114B-1

OFFICE

A114A-1

VEST

A116-1

OFFICE

A118-1

LOBBY

A100-1

OFFICE

C272-1

OFFICE

B196-1

PHARMACY

ADMINISTRATION

A150-1

STORAGE

B137B-1

WAITING

D420-1

CT SCAN

CONTROL

D421-1

CT SCAN 3

D422-1

OFFICE

A103-1

OFFICE/STORAGE

B226A-1

GENERAL

CLINIC

WAITING

AREA

FEC

TOILET

D370-1

SCRUB

C438-1

TOILET

D301B-1

CONTROL

D301A-1

CONTROL

NURSE

STATION

C286C-1

FEC

RECEPTION

C244E-1

FEC

DATA

C447-1

DATA

C448-1

DATA

C449-1DATA

C450-1

B451-1

ANTE ROOM

CTICU

B188-1

OFFICE

B225A-1

OFFICE

B217A-1

EXAM

B227-1

FEC

EXAM

B136A-1

OFFICE

B137D-1

FEC

DATA

DIRECTORS'

OFFICES

A110-1

FEC

BREAK

ROOM

A164F-1

X-RAY

DIAGNOSTIC

II

D338-1

LOUNGE

C265B-1

ELEVATOR

S-1

ELEVATOR

S-2

ELEVATOR

P-4

ELEVATOR

P-3

ELEVATOR

P-6

ELEVATOR

P-5

STAIR

3-1

STAIR

2-1

STAIR

1-1

STAIR

4-1

OFFICE

A114D-1

STORAGE

A164N-1

STORAGE

A164O-3

ANTE ROOM

STORAGE

STORAGE

A405-1

OFFICE

A140B-1

FEC

STORAGE

FEC

NURSE

STATION

B188B-1

STORAGE

C244J-1

STORAGE

C259C-1

PACU

C286-1

FEC

OFFICE

D364-1

OFFICE

D337B-1

FEC

CONTROL

D308A-1

CONTROL

D307A-1

OFFICE

D341E-1

RECEPTION

OFFICE

D324-1

OFFICE

D323-1

TCA1B

CORRIDOR

C1-26-1

FEC

POOL

VENDING

C1-26A-1

ELEVATOR A

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

1 1

4 4

2 TYP

TYP

1 1

MENS

RESTROOM

B212-1

WOMENS

RESTROOM

B211-1

6 5

D A

C B

EF

G

KEY PLAN

TRUE

NORTH

PLAN

NORTH

DEMO PLAN GENERAL NOTES

A. CONTRACTOR SHALL GUT AND REMOVE ALL EXISTING CONSTRUCTION DOWN TO EXISTING STUDS/ STRUCTURE REQUIRED TO INSTALL NEW WORK AND SHALL DISPOSE OF ALL DEMOLISHED MATERIALS IN

AN APPROVED, OFFSITE LANDFILL EXCEPT WHERE OTHERWISE REQUIRED FOR SALVAGE OR

RECYCLING.

B. CONTRACTOR SHALL DEMOLISH ALL EXISTING MILLWORK, TOILET ACCESSORIES, GRAB BARS, COUNTERTOPS, AND TOILET PARTITIONS IN AREA OF WORK.

C. REFER TO AND COORDINATE WITH OTHER DICSIPINES DRAWINGS AND DOCUMENTS FOR ADDITIONAL

INFORMATION AND INSTRUCTIONS.

D. REMOVE AND STORE EXISTING SIGNAGE FOR REINSTALLATION.

E. DEMOLISH EXISTING FLOORING & BASE INCLUDING FLOORING UNDERLAYMENT IN AREA OF WORK AS

NEEDED TO INSTALL NEW WORK.

EXISTING DOOR, HARDWARE AND FRAME ASSEMBLY TO REMAIN. PREPARE SURFACE FOR NEW FINISH.

DEMO FLOOR PLAN KEY NOTES #

2 DEMOLISH EXISTING LOCKERS AND BENCHES.

3 DEMOLISH EXISTING WALL & FLOOR EXPANSION JOINT COVER IN AREA OF WORK AS INDICATED.

4 DEMOLISH EXISTING DOOR, FRAME ASSEMBLY AND HARDWARE AS INDICATED.

5 REMOVE EXISTING EQUIPMENT, RELOCATE AND STORE AT A APPROVED LOCATION FOR

REINSTALLATION.

DEMO PLAN LEGEND

EXISTING CONSTRUCTION

TO REMAIN

EXISTING CONSTRUCTION TO BE

DEMOLISHED

2-HOUR FIRE BARRIER

1-HOUR FIRE BARRIER

AREA OF WORK

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

Date:

Drawing Title:

Approved Project Director

Project Title:

1 2 3 4 5 6 7 8 9

FINAL CONTRACT

SUBMITTAL590 MEANS ST NW

Phase Project Number

Building Number

Drawing NumberLocation

Issue Date CheckedFULLY SPRINKLERED

STAMP

STE. 200

ATLANTA, GA 30318

ARCHITECT/ENGINEER OF RECORDCONSULTANT

A

B

C

D

E

F

U.S. Department of Veterans Affairs

Office of Construction and

Facilities Management

Drawn

1 & 12

SJ/EO/SMTS

573-20-604

OVERALL FIRST FLOOR DEMO

PLAN - AREA A, B, C & D

RENOVATE COMMON AREA

RESTROOMS

GAINESVILLE, FLORIDA

AD104

03-21-2024

1/16" = 1'-0"AD104

1 FIRST FLOOR DEMO PLAN - AERA A,B,C,D

SCALE:

0' 8' 16' 32' 48'

1/16" = 1' - 0" smittal Snapshot smittal Image smittal

B

C

D

E

F

G

H

J

K

L

25 24 23 22 21.2 20 19 18 17 16

D1

E1

K5

M

20.221.4

209 SF

OFFICE

E126E-1

37 SF

MECH

E126D-1

117 SF

LOUNGE

E126C-1

127 SF

OFFICE

E126A-1

960 SF

CORRIDOR

CE-8-1

169 SF

OFFICE

E182-1

144 SF

CHIEF

OFFICE

E181-1

99 SF

RECEPTION

E193A-1

5418 SF

CHEMISTRY

AND

MICROBIOLOGY

E126-1

20 SF

TOILET

E194B-1

25 SF

DRESS

E149A-1

234 SF

X-RAY

GENERAL

E149-1

599 SF

CORRIDOR

CE-9-1

34 SF

TOILET

E183-1

103 SF

OFFICE

E184-1

99 SF

OFFICE

E185-1

104 SF

OFFICE

E187-1

134 SF

LOUNGE

E188-1

91 SF

TOILET

E189-1

96 SF

OFFICE

E190-1

279 SF

READING

ROOM

E191-1 183 SF

MECH

E197-1

429 SF

OPERATING

ROOM E

E175-1

115 SF

SUB STERILE

E173-1

436 SF

OPERATING

ROOM F

E171-1

39 SF

HAC

E170A-1

57 SF

STORAGE

E170-1

212 SF

EQUIPMENT

ROOM

E179B-1

392 SF

TOMOGRAPHIC

TREATMENT

ROOM

E195B-1

115 SF

SCRUB

E171A-1

533 SF

CORRIDOR

CE-15-1

117 SF

SCRUB

E176A-1

147 SF

ELEC

E169-1

623 SF

OPERATING

ROOM H

E176-1

101 SF

SUB STERILE

E174-1

545 SF

OPERATING

ROOM G

E172-1

85 SF

STORAGE

E177-1

101 SF

GAS

STORAGE

E177A-1

383 SF

EMERGENCY

ENTERANCE

E-C1-1

1659 SF

WAITING

E100-1

211 SF

RECEPTION

A101A-1

100 SF

EXAM

E104-1

92 SF

EXAM

E105-1

69 SF

CORRIDOR

E-C1-6-1

61 SF

TOILET

E106-1

181 SF

CORRIDOR

E-C1-5-1

150 SF

OFFICE

E118-1 228 SF

ELEVATOR B

E-C1-7-1

119 SF

OFFICE

E103-1

154 SF

LOCKER

ROOM

E102-1

45 SF

TOILET

E102A-1

37 SF

HAC

E114-1

168 SF

CORRIDOR

E-C1-4-1

112 SF

SECURITY

E101-1

91 SF

MEDIC

E116-1

301 SF

LIFE

SUPPORT

E113-1

277 SF

ELEVATOR B

E-C1-14-1

60 SF

RESTROOM

E108-1

369 SF

NURSE

STATION

E115-1

123 SF

CLEAN

SUPPLY

E112-1

93 SF

SOILED

UTILITY

E111-1

74 SF

TOILET

E117B-1

100 SF

ON-CALL

E117-1

291 SF

MINOR

OPERATING

ROOM

E110-1

1047 SF

CORRIDOR

E-C1-11-1

107 SF

CORRIDOR

E-C1-15-1 67 SF

INTERVIEW

ROOM

E128-1

576 SF

CORRIDOR

E-CQ-16-1

182 SF

SOILED

HOLDING

E135-1

86 SF

ELEC

E155-1

128 SF

DATA

E156-1 131 SF

PERIOPERATIVE

EDUCATION

E154-1 162 SF

CORRIDOR

E-C1-12

37 SF

TOILET

E153-1

130 SF

OFFICE

E152-1

52 SF

VEST

E151C-1

477 SF

MENS

LOCKER

ROOM

E151-1

321 SF

WOMENS

LOCKER

ROOM

E150-1

183 SF

DRESSING

ROOM

E150D-1

87 SF

VEST

E150A-1

173 SF

WOMENS

TOILET

E150B

59 SF

DICTATION

268 SF

MENS

TOILET

E151B-1

50 SF

VEST

E151A-1

168 SF

STORAGE

E142C-1

41 SF

TOILET

E140B-1

161 SF

NURSE

STATION

E140-1

52 SF

HAC

E141-1

69 SF

STORAGE

E141A-1

538 SF

OPERATING

ROOM K

E142-1

351 SF

STERILE

STORAGE

E148-1

86 SF

OFFICE

E146-1

478 SF

OPERATING

ROOM J

E144-1

760 SF

CLEAN CORR

1-C1-21

249 SF

SUB-STERILE

E145-1

483 SF

OPERATING

ROOM I

E143-1

212 SF

STORAGE

E147-1

90 SF

CORRIDOR

E-C1-22-1

153 SF

CORRIDOR

E-C1-23-1

144 SF

CORRIDOR

E-C1-24-1

99 SF

BED 4

E109-1

1434 SF

CORRIDOR

E-C1-8-1

210 SF

STAIR

1-5

206 SF

STAIR

1-6

80 SF

ELEVATOR

73 SF

ELEVATOR

73 SF

ELEVATOR

77 SF

ELEVATOR

106 SF

SECLUSION

E109A-1

91 SF

BED 5

12 SF

ELEC

E109B-1

79 SF

PATIENT

VALUABLES

E107-1

88 SF

STORAGE

E142A-1

159 SF

CONTROL

E140A-1

30 SF

NUTRITION

1705 SF

RECOVERY

462 SF

WORK ROOM

STORAGE

E178A-1

90 SF

CONTROL

E195A-1

115 SF

CONTROL

E179A-1

397 SF

SCAN ROOM

E179-1

279 SF

STORAGE

E136-1

84 SF

RECEPTION

E193B-1

119 SF

OFFICE

E126B-1

256 SF

STORAGE

16 SF

DATA

E170B-1

16 SF

46 SF

LOCKERS

E128A-1

136 SF

STORAGE

92 SF

BED 3

96 SF

BED 2

96 SF

BED 1

69 SF

REFRIGERATOR

56 SF

REFRIGERATOR

51 SF

STORAGE

D A

C B

EF

G

TRUE

NORTH

PLAN

NORTH

DEMO GENERAL NOTES

A. CONTRACTOR SHALL GUT AND REMOVE ALL EXISTING CONSTRUCTION DOWN TO EXISTING STUDS/ STRUCTURE REQUIRED TO INSTALL NEW WORK AND SHALL DISPOSE OF ALL DEMOLISHED MATERIALS IN

AN APPROVED, OFFSITE LANDFILL EXCEPT WHERE OTHERWISE REQUIRED FOR SALVAGE OR

RECYCLING.

B. CONTRACTOR SHALL DEMOLISH ALL EXISTING MILLWORK, TOILET ACCESSORIES, GRAB BARS, COUNTERTOPS, AND TOILET PARTITIONS IN AREA OF WORK.

C. REFER TO AND COORDINATE WITH OTHER DICSIPINES DRAWINGS AND DOCUMENTS FOR ADDITIONAL

INFORMATION AND INSTRUCTIONS.

D. REMOVE AND STORE EXISTING SIGNAGE FOR REINSTALLATION.

E. DEMOLISH EXISTING FLOORING & BASE INCLUDING FLOORING UNDERLAYMENT IN AREA OF WORK AS

NEEDED TO INSTALL NEW WORK.

DEMO FLOOR PLAN KEY NOTES #

1 EXISTING DOOR, HARDWARE AND FRAME ASSEMBLY TO REMAIN. PREPARE SURFACE FOR NEW FINISH.

0' 4' 8' 16' 24'

SCALE: 3/32" = 1'-0"

32'

DEMO PLAN LEGEND

EXISTING CONSTRUCTION

TO REMAIN

EXISTING CONSTRUCTION TO BE

DEMOLISHED

2-HOUR FIRE BARRIER

1-HOUR FIRE BARRIER

AREA OF WORK

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

Date:

Drawing Title:

Approved Project Director

Project Title:

1 2 3 4 5 6 7 8 9

FINAL CONTRACT

SUMBITTAL590 MEANS ST NW

Phase Project Number

Building Number

Drawing NumberLocation

Issue Date CheckedFULLY SPRINKLERED

STAMP

STE. 200

ATLANTA, GA 30318

ARCHITECT/ENGINEER OF RECORDCONSULTANT

A

B

C

D

E

F

U.S. Department of Veterans Affairs

Office of Construction and

Facilities Management

Drawn

1 & 12

SJ/EO/SMTS

573-20-604

OVERALL FIRST FLOOR DEMO

PLAN - AREA E

RENOVATE COMMON AREA

RESTROOMS

GAINESVILLE, FLORIDA

AD105

03-21-2024

3/32" = 1'-0"AD105

1 OVERALL FIRST FLOOR DEMO PLAN - AREA E

KEY PLAN E

smittal Snapshot smittal Image smittal

2526272829303132

B.2

C.2

D.2

E.2

333435

E.7

F.5

G.7

J

K.3

M

M.6

N

E.8 j k l

SOILED

UTILITY

F107-1

VEST

F103I-1

UNOCCUPIED

F108-1

UNOCCUPIED

F109-1

UNOCCUPIED

F110-1

UNOCCUPIED

F111-1

ASSIST.

CHIEF

PATIENT

PROCESSING

F102-1

ADMISSIONS

F101-1

CORRIDOR

F-C1-5

SOCIAL

WORK

F104-1

SOCIAL

WORK

F105-1

WAITING

F-C1-3

LOBBY

F-C1-2

VEST

F-C1-1

RELEASE OF

INFORMATION

F138-1

TRAVEL

F139-1

STAIR

RECEPTION

F-C1-7

CORRIDOR

F-C1-8

TOILET

F120-1

CORRIDOR

F-C1-10

ASSIST.

NURSE

MANAGER

EDUCATOR

F114-1

EXAM

F115-1

CHIEF

PRIMARY

CARE

F116-1

NURSE

MANAGER

F117-1

SECRETARY

PRIMARY

CARE

F118-1

CHIEF

MEDICAL

OFFICER

F119-1

ADMIN.

OFFICER

PRIMARY

CARE

F121-1

ACOS CHIEF

NURSE PCO

F123-1

CHIEF

F123A-1

ADMIN.

OFFICER

PRIMARY

CARE

F125-1

ASSIST.

CHIEF

NURSE

F127-1

SUPERVISORY

PROG

SUPPORT

ASSISTANT

F129-1

ELEC

F137-1

STORAGE/FUT.

ELEV.

F136-1

MENS

TOILET

F135-1

WOMENS

TOILET

F134-1

DATA

F122-1

FACILITY

TELEHEALTH

COOD/

MANAGEMENT

& PROG

ANALYST

F124-1

HEALTH

PROMOTION

DISEASE

PREVENTION

F126-1

VETERANS

HEALTH

EDUCATION

COOR

F128-1

PCMM

COORDINATOR

F130-1

ELEVATOR

LOBBY

F-C1-14

CORRIDOR

F-C1-13

PRIMARY

CARE

CONFERENCE

F131-1

SUPERVISORY

PROG

SPECIALIST

F132-1

LEAD

MEDICAL

SUPPORT

ASSIST.

F133-1

CORRIDOR

F-C1-11

CORRIDOR

F-C1-12

WAITING

C-G1-17-1

NUTR. CLINIC

G167-1

OFFICE

G168K-1

DIET. O.

G169-1

DIET. O.

G170-1

PHARMACIST

CONSULTATION

G171-1

OFFICE

G168L-1

CORRIDOR

GC116-1

PHARMACIST

G100-1

EXAM

G101-1

EXAM

G102-1

EXAM

G103-1

EXAM

G104-1

EXAM

G105-1

EXAM

G106-1

EXAM

G107-1

EXAM

G108-1

EXAM

G109-1

EXAM

G110-1

PROCEDURE

G111-1

CLEAN

SUPPLY

G112-1

CORRIDOR

GC113-1

MENS

TOILET

G113-1

WOMENS

TOILET

G114-1

VENDING

F-C1-15

WAITING

GC12-1

WORK ROOM

GC15A-1

RECEPTION

GC15-1

EXAM

G116-1

EXAM

G117-1

EXAM

G118-1

EXAM

G119-1

EXAM

G120-1

EXAM

G121-1

EXAM

G122-1

EXAM

G123-1

EXAM

G124-1

EXAM

G125-1

CONF.

CENTER

G126-1

STAFF

LOUNGE

G127-1

PHARMACIST

GC15B-1

EXAM

GC129-1

EXAM

G130-1

EXAM

G131-1

EXAM

G132-1

EXAM

G133-1

EXAM

G134-1

EXAM

G135-1

EXAM

G136-1

CONSULT

(TB)

G137-1

SOILED

UTILITY

G138-1

HAC

G139-1

MENS

TOILET

G140-1

WOMENS

TOILET

G141-1

TOILET

G142-1

WORK ROOM

G117A-1

EXAM

G144-1

EXAM

G145-1

EXAM

G146-1

EXAM

G147-1

EXAM

G148-1

EXAM

G149-1

EXAM

G150-1

EXAM

G151-1

EXAM

G152-1

PC3

NURSING

G153-1

EXAM

G154-1

WORK ROOM

G117B-1

EXAM

G156-1

WORK ROOM

G119A-1

EXAM

G158-1

WORK ROOM

G119B-1

EXAM

G160-1

EXAM

G111A-1

CONSULT

(TB)

G162-1

ELEC

G163-1

RADIOLOGY

SUITE

G164-1

PROC.(CAST)

G165-1

MED. &

TREAT.

G166-1

OFFICE

G111B-1

EXAM

G155-1

CONSULT

G157-1

TOILET

G159-1

DATA

G161-1

TOILET

G164A-1

CORRIDOR

CORRIDOR

GC114-1

CORRIDOR

GC110-1

CORRIDOR

GC118-1

CORRIDOR

CORRIDOR

CONFERENCE

ROOM

G168J-1

WOMENS

TOILET

G168H-1

MENS

TOILET

G168G-1

HAC

G168F-1

TOILET

G127A-1

ONCOLOGY

G168E-1

OFFICE

GC115-1

OFFICE

G168D-1

CHIEF OF

OPERATIONS

G168C-1

OUTPATIENT

PHARMACY

SUPERVISOR

G168B-1

ORDER

ENTRY

G168A-1

OUTPATIENT

PHARMACY

G168-1

RECEPTION

GC117-1

RECEPTION

GC119-1

RECEPTION

GC111-1

WAITING

GC112-1

STAIR

WAITING

GC11-1

ADMISSIONS

OFFICE

F112-1

CLEAN

UTILITY

F103G-1

ALCOVE

MED ROOM

F103F-1

EXAM 5

F103E-1

EXAM 4

F103D-1EXAM 3

F103C-1

EXAM 2

F103B-1

EXAM 1

F103A-1

EXAM

F103-1

TOILET

F106-1

E.R. / CHEST

PAIN UNIT

F103H-1

COPY

F131A-1

CONTROL

ROOM

G164B-1

EXAM

EXAM

OFFICE

F143-1

OFFICE

F141-1

8' - 7 3/16"

1 1

D A

C B

EF

G

TRUE

NORTH

PLAN

NORTH

0' 4' 8' 16' 24'

SCALE: 3/32" = 1'-0"

32'

DEMO PLAN LEGEND

EXISTING CONSTRUCTION

TO REMAIN

EXISTING CONSTRUCTION TO BE

DEMOLISHED

2-HOUR FIRE BARRIER

1-HOUR FIRE BARRIER

AREA OF WORK

DEMO GENERAL NOTES

A. CONTRACTOR SHALL GUT AND REMOVE ALL EXISTING CONSTRUCTION DOWN TO EXISTING STUDS/ STRUCTURE REQUIRED TO INSTALL NEW WORK AND SHALL DISPOSE OF ALL DEMOLISHED MATERIALS IN

AN APPROVED, OFFSITE LANDFILL EXCEPT WHERE OTHERWISE REQUIRED FOR SALVAGE OR

RECYCLING.

B. CONTRACTOR SHALL DEMOLISH ALL EXISTING MILLWORK, TOILET ACCESSORIES, GRAB BARS, COUNTERTOPS, AND TOILET PARTITIONS IN AREA OF WORK.

C. REFER TO AND COORDINATE WITH OTHER…