Attachment 03 - Drawings 573-20-604 95 pages.pdf
PDF 31 MB Posted
- Attached to
- Y1DA--BB - Renovate Common Area Restrooms
- Solicitation number
- 36C24825R0119
About this file
This document is a set of architectural and engineering drawings for a renovation project at the Malcom Randall VA Medical Center in Gainesville, Florida. The project involves renovating common area restrooms throughout the Basement and First Floor of Building 1, E-Wing and ACA, as well as the First Floor of Building 12. The comprehensive drawing set includes detailed plans for demolition, plumbing, HVAC, electrical, and architectural modifications across multiple building areas.
The drawings cover extensive renovation work, including replacing fixtures, updating electrical and plumbing systems, modifying ceiling layouts, and upgrading restroom facilities. The project scope involves precise demolition and reconstruction of restrooms, with specific attention to accessibility requirements, electrical connections, and mechanical systems. The contract period is 730 calendar days from the Notice to Proceed, and the work encompasses detailed modifications to multiple building areas, ensuring comprehensive upgrades to the medical center's restroom infrastructure.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHEET INDEX
G001
SHEET
NO. DRAWING TITLE
GENERAL
G002
ARCHITECTURAL
SHEET
NO.
COVER SHEET
GENERAL NOTES, DETAILS, ABBREVIATIONS AND LEGENDS
LOCATION MAP
NOT TO SCALE
AREA MAP
NOT TO SCALE
OVERALL FIRST FLOOR DEMO PLAN - AREA F & GAD106
TRUE
NORTH
TRUE
NORTH
RENOVATE COMMON AREA RESTROOMS
PROJECT NO. 573-20-604
FINAL CONTRACT SUBMITTAL
MALCOM RANDALL VA MEDICAL CENTER
GAINESVILLE, FL 32608
PLAN
NORTH
PLAN
NORTH
OVERALL BASEMENT DEMO PLAN - AREA A, B, C & DAD101
OVERALL BASEMENT DEMO PLAN - AREA F & G
OVERALL FIRST FLOOR DEMO PLAN - AREA A, B, C & DAD104
OVERALL FIRST FLOOR DEMO PLAN - AREA EAD105
AD103
OVERALL BASEMENT DEMO PLAN - AREA EAD102
AD107 OVERALL FIRST FLOOR DEMO PLAN - BUILDING 12
A101 OVERALL BASEMENT PLAN - AREA A, B, C & D
PROJECT AREAPROJECT AREA
A102 OVERALL BASEMENT PLAN - AREA E
A103 OVERALL BASEMENT PLAN - AREA F & G
A104 OVERALL FIRST FLOOR PLAN - AREA A, B, C & D
A105 OVERALL FIRST FLOOR PLAN - AREA E
A106 OVERALL FIRST FLOOR PLAN - AREA F & G
A107 OVERALL FIRST FLOOR PLAN - BUILDING 12
A401 ENLARGED FLOOR PLANS - AREA A, B, C & D
A402 ENLARGED FLOOR PLANS - AREA A, B, C & D
A403 ENLARGED FLOOR PLANS - AREA E
A404 ENLARGED FLOOR PLANS - AREA F & G
A405 ENLARGED FLOOR PLANS - BUILDING 12
PLUMBING
OVERALL BASEMENT PLUMBING PLAN - AREA EP102
OVERALL BASEMENT DEMO PLUMBING PLAN - AREA A, B, C & D PD101
OVERALL BASEMENT DEMO PLUMBING PLAN - AREAS F & G
OVERALL FIRST FLOOR DEMO PLUMBING PLAN - AREA A, B, C & D PD104
P101
PD103
OVERALL BASEMENT DEMO PLUMBING PLAN - AREA EPD102
P103 OVERALL BASEMENT PLUMBING PLAN - AREAS F & G
P104 OVERALL FIRST FLOOR PLUMBING PLAN - AREAS A, B, C & D
P105 OVERALL FIRST FLOOR PLUMBING PLAN - AREA E
P106 OVERALL FIRST FLOOR PLUMBING PLAN - AREAS F & G
P107 OVERALL FIRST FLOOR PLUMBING PLAN - BUILDING 12
P401 ENLARGED PLUMBING FLOOR PLANS - BUILDING 1 AREA ABCD
P402 ENLARGED PLUMBING FLOOR PLANS - BUILDING 1 AREA ABCD
P403 ENLARGED PLUMBING FLOOR PLANS - AREA E
P404 ENLARGED PLUMBING FLOOR PLANS BUILDING 1 - AREAS F & G
P405 ENLARGED PLUMBING FLOOR PLANS BUILDING 12
OVERALL BASEMENT PLUMBING PLAN - AREAS A, B, C & D
A601 SCHEDULES, TYPES AND DETAILS - AREA A, B, C & D
A602 SCHEDULES, TYPES AND DETAILS - AREA E
A603 SCHEDULES, TYPES AND DETAILS - AREA F & G
A604 SCHEDULES, TYPES AND DETAILS - BUILDING 12
OVERALL FIRST FLOOR DEMO PLUMBING PLAN - AREA E PD105
OVERALL FIRST FLOOR DEMO PLUMBING PLAN - AREAS F & GPD106
OVERALL FIRST FLOOR DEMO PLUMBING PLAN - BUILDING 12PD107
MECHANICAL
OVERALL BASEMENT HVAC PLAN - AREAS A, B, C & D M101
OVERALL BASEMENT HVAC PLAN - AREAS F & G
OVERALL FIRST FLOOR HVAC PLAN - AREA A, B, C & D M104
M103
OVERALL BASEMENT HVAC PLAN - AREA EM102
OVERALL FIRST FLOOR HVAC PLAN - AREA E M105
OVERALL FIRST FLOOR HVAC PLAN - AREAS F & GM106
OVERALL FIRST FLOOR HVAC PLAN - BUILDING 12M107
M401 ENLARGED HVAC FLOOR PLANS - BUILDING 1 AREA ABCD
M402 ENLARGED HVAC FLOOR PLANS - BUILDING 1 AREA ABCD
M403 ENLARGED HVAC FLOOR PLAN - AREA E
M404 ENLARGED HVAC FLOOR PLAN - AREA F & G
M405 ENLARGED HVAC FLOOR PLANS - BUILDING 12
M500 HVAC DETAILS
ELECTRICAL
ELECTRICAL LEGEND AND NOTESE001
OVERALL BASEMENT ELECTRICAL PLAN - AREA F & G
OVERALL FIRST FLOOR ELECTRICAL PLAN - AREAS A, B, C & D E104
E102
OVERALL BASEMENT ELECTRICAL PLAN - AREAS A, B, C & DE101
OVERALL FIRST FLOOR ELECTRICAL PLAN - AREA E E105
OVERALL FIRST FLOOR ELECTRICAL PLAN - AREA F & GE106
OVERALL FIRST FLOOR ELECTRICAL PLAN - BUILDING 12E107
E401 ENLARGED ELECTRICAL PLANS - BUILDING 1 AREAS ABCD
E402 ENLARGED ELECTRICAL PLANS - BUILDING 1 AREAS ABCD
E403 ENLARGED ELECTRICAL PLANS - AREA E
E404 ENLARGED ELECTRICAL PLANS - BUILDING 1 AREA F&G
E405 ENLARGED ELECTRICAL PLANS - BUILDING 12
OVERALL BASEMENT ELECTRICAL PLAN - AREA E
E103
A451 INTERIOR ELEVATIONS - AREA A, B, C & D
A452 INTERIOR ELEVATIONS - AREA A, B, C & D
INTERIOR ELEVATIONS - AREA A, B, C & DA453
INTERIOR ELEVATIONS - AREA EA454
INTERIOR ELEVATIONS - AREA F & GA455
INTERIOR ELEVATIONS - BUILDING 12A456
AD111 OVERALL BASEMENT DEMO RCP - AREA A, B, C & D
AD112 OVERALL BASEMENT DEMO RCP - AREA E
AD113 OVERALL BASEMENT DEMO RCP - AREA F & G
OVERALL FIRST FLOOR DEMO RCP - AREA A, B, C & DAD114
OVERALL FIRST FLOOR DEMO RCP - AREA EAD115
OVERALL FIRST FLOOR DEMO RCP - AREA F & GAD116
OVERALL FIRST FLOOR DEMO RCP - BUILDING 12AD117
A111 OVERALL BASEMENT RCP - AREA A, B, C & D
A112 OVERALL BASEMENT RCP - AREA E
A113 OVERALL BASEMENT RCP - AREA F & G
OVERALL FIRST FLOOR RCP - AREA A, B, C & DA114
OVERALL FIRST FLOOR RCP - AREA EA115
OVERALL FIRST FLOOR RCP - AREA F & GA116
OVERALL FIRST FLOOR RCP - BUILDING 12A117
A411 ENLARGED RCP - AREA A, B, C & D
A412 ENLARGED RCP - AREA A, B, C & D
A413 ENLARGED RCP - AREA E
A414 ENLARGED RCP - AREA F & G
A415 ENLARGED RCP - BUILDING 12
VA FORM 08-6231
1 2 3 4 5 6 7 8 9
Date:
Drawing Title:
Approved Project Director
Project Title:
1 2 3 4 5 6 7 8 9
FINAL CONTRACT
SUBMITTAL590 MEANS ST NW
Phase Project Number
Building Number
Drawing NumberLocation
Issue Date CheckedFULLY SPRINKLERED
STAMP
STE. 200
ATLANTA, GA 30318
ARCHITECT/ENGINEER OF RECORDCONSULTANT
A
B
C
D
E
F
U.S. Department of Veterans Affairs
Office of Construction and
Facilities Management
Drawn
1 & 12
SJ/EO/SMTS
573-20-604
COVER SHEET RENOVATE COMMON AREA
RESTROOMS
GAINESVILLE, FLORIDA
G001 03-21-2024 smittal Snapshot smittal Image smittal Text Box 03-21-2024
ARCHITECTURAL ABBREVIATIONS
GENERAL PROJECT NOTES
ALUMINUM COMPOSITE METAL PANELS
ACOUSTICAL CEILING TILE
ABOVE FINISH FLOOR
ALUMINUM
BATT INSULATION
BOTTOM OF
CEMENTITIOUS BACKER BOARD
CEMENTITIOUS CRYSTALLINE WATERPROOFING
COLD-FORMED METAL FRAMING
CORNER GUARD
CENTERLINE
CONCRETE MASONRY UNIT
CASED OPENING
COMMUNICATION
CONCRETE
SEALED CONCRETE
CONTINUOUS
CONTRACTING OFFICER'S REPRESENTATIVE
CERAMIC TILE
CERAMIC TILE BASE
CARPET
DIAMETER
EXPANSION JOINT
ELECTRICAL
EQUAL
EXPOSED STRUCTURE
ET CETERA
EXISTING
EXPOSED
FACTORY FINISH
FLOOR DRAIN
FIRE EXTINGUISHER CABINET
FIRE HOSE CABINET
FINISHED FLOOR
FINISH
FLOOR
FACE OF
FIELD VERIFY
FABRIC WALLCOVERING
GAGE
GRANITE
GYPSUM (WALL) BOARD
HANDICAPPED
HOLLOW METAL
HANDRAIL
HEATING VENTILATION AND AIR-CONDITIONING
MATERIAL
MAXIMUM
MECHANICAL
MANUFACTURER
MINIMUM
MASONRY OPENING
METAL
NOT IN CONTRACT
NOT TO SCALE
ON CENTER
OPPOSITE HAND
PLASTER
PLASTIC LAMINATE
PORCELAIN TILE
PAIR
PAINT
QUARRY TILE
RESILIENT BASE
REFRIGERATOR
REQUIRED
RESINOUS FLOORING
RESINOUS EPOXY WALL-CEILING
ROUGH OPENING
RUBBER FLOORING
RECESSED PAPER HOLDER
SEALED HIGH BUILD GLAZED COATING
SOLID CORE WOOD
SIMILAR
SPECIAL FACED
STAINLESS STEEL/ SOLID SURFACE
STEEL
SUBSTRATE
SHEET VINYL
SOLID VINYL TILE
TELEPHONE
TOP OF
TYPICAL
UNLESS NOTED OTHERWISE
VINYL COMPOSITION TILE
VINYL WALL COVERING
WALL COVERING
WALL PROTECTION
WOOD
WELDED SEAM SHEET FLOORING
ACMP
AT
AFF
AL
BATT
BO
CBB
CCW
CFMF
CG
C
CMU
CO
COMM
CONC
SCONC
CONT
COR
CT
CTB
CP
DIA
EJ
ELEC
EQ
ES
ETC
EXIST
EXP
FAC FIN
FD
FEC
FHC
FF
FIN
FLR
FO
FV
FWC
GA
GRA
GYP BD/GWB
HC
HM
HR
HVAC
MATL
MAX
MECH
MFR
MIN
MO
MTL
NIC
NTS
OC
OH
PLS
PL
PT
PR
P
QT
RB
REF
REQ'D
RES-3
RES-W
RO
RF
RPH
SC
SCW
SIM
SP
SS
STL
SUBS
SV
SVT
TELE
TO
TYP
UNO
VCT
VWC
WC
WP
WD
WSF
L
A. THE CONTRACTOR SHALL BE PREPARED TO STOP ANY WORK AND CLEAR UP THE
WORK AREA IF SO ASKED IN MEDICAL SITUATIONS REQURING SUCH ACTION.
B. THE CONTRACTOR SHALL NOT ORDER OR INSTALL ANY MATERIALS OR
EQUIPMENT UNTIL SUBMITTALS FOR SUCH HAVE BEEN APPROVED.
C. ALL TOOLS AND MATERIALS USED IN THIS PROJECT SHALL BE PROPERLY
SECURED AT ALL TIMES BY THE CONTRACTOR TO REDUCE POSSIBILITY OF
ANY OF THESE TOOLS BEING A HAZARD TO PATIENTS, VISITORS, OR
STAFF.
D. THE CONTRACTOR WILL BE RESPONSIBLE FOR ACQUIRING I.D. BADGES FOR
EACH MEMBER OF HIS WORK FORCE. VALID FORMS OF I.D. ARE REQUIRED
TO RECEIVE BADGES. COORDINATE WITH COR.
E. THE CONTRACTOR, AT HIS EXPENSE, WILL BE RESPONSIBLE FOR TRAINING
EACH MEMBER OF HIS WORK FORCE ON VA POLICIES FOR ON-SITE WORK
BEFORE ANY MEMBER WILL BE ALLOWED TO PERFORM WORK ON VA
PREMISES.
F. ABSOLUTELY NO VA TOOLS, MATERIALS, OR EQUIPMENT WILL BE LOANED OR
GIVEN BY THE VA TO ANY MEMBER OF THE CONTRACTOR'S WORK FORCE
AT ANY TIME.
G. ANY SMOKE DETECTORS HAVING ANY POTENTIAL FOR EXPOSURE TO CONSTRUCTION
SMOKE, DUST, AND DEBRIS SHALL BE SUITABLY PROTECTED TO PREVENT ACCIDENTAL
ALARM DURING CONSTRUCTION. ALL SUCH ACTION MUST BE FIRST COORDINATED AND
CLEARED WITH COR AND THE VA SAFETY OFFICER. ALL FUNCTIONAL FIRE ALARM
DEVICES SHALL BE ACTIVE WHENEVER CONTRACTOR'S FORCES ARE NOT PRESENT IN
WORK AREA.
H. THE CONTRACTOR MUST PROVIDE WRITTEN FIRE SAFETY CHECKLIST AT THE
END OF EVERY WORK DAY TO THE COR CERTIFYING THAT ALL WORK AREAS
HAVE BEEN SURVEYED AND FOUND TO BE SECURE, SAFE, AND FREE OF
ANY FLAMMABLE LIQUIDS.
I. CONTRACTOR SHALL COORDINATE ONLY WITH THE COR AND CONTRACTING
OFFICER.
J. SEE SPECIFICATION SECTION 01 00 00 AND 01 35 26 FOR INTERIM LIFE SAFETY MEASURES.
K. ALL FINISH COLORS TO BE SELECTED BY COR/ VA INTERIOR DESIGNER WHERE NOT
OTHERWISE INDICATED. CONTRACTOR SHALL SUBMIT THE COLORS FROM
MANUFACTURER'S FULL RANGE OF COLORS.
L.
M.
PROVIDE 24" x 24" ACCESS PANELS IN HARD CEILINGS WHERE DUCTS AND DAMPERS OR
OTHER PIPES REQUIRE ACCESS AS REQUIRED. COORDINATE EXACT LOCATION W/COR.
THE CONTRACTOR SHALL NOT OPERATE ANY EXISTING VA EQUIPMENT WITHOUT
AUTHORIZATION FROM THE VAMC ENGINEERING SERVICE, UNLESS AN EMERGENCY
SITUATION EXISTS.
CARD READERCR
HIGH-PRESSURE LAMINATEHPL
LUXURY VINYL TILELVT
EDGE OF DECKEOD
DOWNSPOUTDS
CONTROL JOINTCJ
DRINKING FOUNTAINDF
FIRE RETARDANT TREATEDFRT
EXTERIOR INSULATION FINISHING SYSTEMEIFS
WATER RESISTANTWR
ARCHITECTURAL LEGEND
A
GA4
A301
A201
A401
ROOM
NAME
+ 0'-6"
F.E.C.
FIRE EXTINGUISHER CABINET
ROOM NAME AND NUMBER
DOOR NUMBER
KEY NOTE
WINDOW TYPE
PARTITION TYPE
DETAIL CALLOUT
DETAIL NUMBER
SHEET WHERE DETAIL IS DRAWN
SECTION CALLOUT
VERTICAL ELEVATION
COLUMN CENTERLINE DESIGNATION
DEMOLITION KEY NOTE
DETAIL NUMBER
SHEET WHERE DETAIL IS DRAWN
ELEVATION CALLOUT
DETAIL NUMBER
SHEET WHERE DETAIL IS DRAWN
J1
SECTION CUT
HEAD/JAMB/SILL DETAIL NUMBER
EQUIPMENT JSN NUMBERX1045
N. CONTRACTOR SHALL MAINTAIN ALL FIRE-RATED ASSEMBLIES WITHIN THE PROJECT
AREA DURING PERFORMANCE OF THE WORK.
AIR CONDITIONINGAC
CARPET TILECPT
EPOXY FLOORINGEPY
REFLECTED CEILING PLANRCP
SOLID SURFACE MATERIALSSM
ACCESSORY TYPEA
O. CONTRACTOR SHALL PROVIDE AND MAINTAIN ALL REQUIRED EXIT LIGHTING AND
SIGNAGE REQUIRED FOR EGRESS WITHIN AND ADJACENT TO THE PROJECT AREA
DURING PERFORMANCE OF THE WORK.
P. INDICATED EXISTING CONDITIONS ARE BASED UPON LIMITED FIELD INVESTIGATION
AND DID NOT INCLUDE DESTRUCTIVE INVESTIGATION OR TESTING, CONTRACTOR
SHALL VERIFY ALL EXISTING CONDITIONS INCLUDING DIMENSIONS OF THE INSTALLED
CONSTRUCTION PRIOR TO COMMENCING WITH THE WORK. IF DISCREPANCIES ARE
DISCOVERED, THE CONTRACTOR SHALL NOTIFY THE COR FOR INTERPRETATION AND
DIRECTION PRIOR TO PROCEEDING WITH THE WORK.
Q. COORDINATE WORK WITH EQUIPMENT SUPPLIER/ INSTALLER CONTRACTED
SEPARATELY WITH THE GOVERNMENT.
FIRE PROTECTION GENERAL NOTES
1. INSTALLATION TO BE IN ACCORDANCE WITH NFPA 13, INTERNATIONAL BUILDING
CODE, LOCAL REQUIREMENTS AND STATE FIRE MARSHALL REQUIREMENTS.
2. ALL PIPING 1 1/2" AND SMALLER SHALL BE SCHEDULE 40 ASTMO52 BLACK STEEL
WITH THREADED FITTINGS AND SHALL COMPLY WITH ASME SEC. 13-1A. ALL
PIPING 2" AND LARGER SHALL BE SCHEDULE 10 ASTM STANDARD BLACK STEEL
PIPING. PLASTIC PIPING IS UNACCEPTABLE. MINIMUM 1" PIPE SHALL BE 1".
3. FIRE SPRINKLER SYSTEM TO BE TESTED @ 200 P.S.I. FOR A MINIMUM OF (2)-
HOURS OR 50 P.S.I. ABOVE STATIC PRESSURE IN EXCESS OF 150 P.S.I. FOR (2)-
HOURS.
4. HANGERS TO BE IN ACCORDANCE WITH NFPA 13, PARAGRAPH 2-6 AND SHALL
BE U.L. LISTED AND F.M. APPROVED WITH 3/8" MINIMUM ROD DIAMETER.
5. HANGER SHALL BE PROVIDED WHEN ARM-OVER IS OVER (1)-FOOT LONG.
6. SPRINKLER LAYOUT IS BASED ON LIGHT HAZARD OCCUPANCY, 0.15 GPM/S.F.
OVER 1,500 SQUARE FEET WITH A MAXIMUM COVERAGE OF 225 SQUARE FEET
PER HEAD.
7. SPRINKLER HEADS IN FINISHED AREAS TO BE 1/2", 1350 F. AS MANUFACTURED
BY VIKING OR APPROVED EQUAL, QUICK RESPONSE.
8. SPRINKLER HEADS IN AREAS WITHOUT CEILING OR IN COMBUSTIBLE
CONCEALED SPACE TO BE 1/2", 1350 F. BRASS UPRIGHT AS MANUFACTURED BY
VIKING OR APPROVED EQUAL, QUICK RESPONSE.
9. FLUSH ALL PIPES BEFORE SPRINKLER ARE IN STALL PER NFPA 13.
10. THE DESIGN INTENT IS FOR THE FIRE MAIN AND SPRINKLER PIPING TO BE
CONCEALED IN WALLS OR ABOVE CEILING CAVITY.
11. BEFORE ANY CUTTING OR WELDING OPERATIONS ARE STARTED CONTRACTOR
SHALL OBTAIN A PERMIT IN ACCORDANCE WITH NFPA 51B-3.2.
12. VALVES TO BE SUPERVISED IN ACCORDANCE WITH NFPA 13.
13. CONTRACTOR SHALL PROVIDE TO THE OWNER ALL LITERATURE AND
INSTRUCTIONS PROVIDED BY THE MANUFACTURER DESCRIBING DEVISES
INSTALLED, CONTRACTOR SHALL ADHERE TO NFPA 25, STANDARD FOR THE
INSPECTION, TESTING AND MAINTENANCE OF THE WATER-BASE FIRE
PROTECTION SYSTEMS.
14. USE 2120 F. HEADS IN NON-AIR CONDITIONED SPACES.
15. CONTRACTOR SHALL INDICATE TEMPERATURE RATING AND LOCATION OF HIGH-
TEMPERATURE SPRINKLER HEADS.
16. INSTALL SPRINKLER HEAD(S) IN CENTER OF CEILING TILES.
17. EXISTING SPRINKLER HEADS BEING REMOVED SHALL NOT BE REINSTALLED,
INSTALL NEW HEADS ONLY.
18. IN RENOVATION PROJECTS THE SPRINKLER SYSTEM SHALL BE MODIFIED TO
ACCOMMODATE THE NEW LAYOUT OF SPRINKLER HEADS, INSTALL NEW PIPING
AS REQUIRED.
FIRE ALARM GENERAL NOTES
A.
B.
C.
D.
E.
F.
EXISTING SYSTEM PRESERVATION
A.
B.
C.
D.
E.
ACTIVATE FIRE PROTECTION
A.
B.
C.
D.
DISRUPTION TO FIRE ALARM AND SPRINKLER SYSTEMS SHALL BE KEPT TO A MINIMUM
OR AVOIDED.
DELINEATE PHASING OF CONSTRUCTION TO ENSURE THAT INSTALLATION OF NEW
SYSTEMS ARE EXPEDITED, AND EXISTING SYSTEMS ARE KEPT IN SERVICE UNTIL THE
REPLACEMENT SYSTEM IS OPERATIONAL.
IF FIRE PROTECTION SYSTEMS ARE TO BE DISRUPTED, PROCEDURES SHALL BE
INCORPORATED INTO THE DESIGN TO MAINTAIN EQUIVALENT LEVELS OF FIRE
PROTECTION AND PROVIDE FORMAL NOTIFICATION TO THE FACILITY WHILE SYSTEMS
ARE DOWN.
AN ACTIVE SPRINKLER SYSTEM, EITHER TEMPORARY OR PERMANENT, SHALL BE IN
PLACE AND OPERATIONAL.
SMOKE DETECTORS SHOULD NOT BE INSTALLED WHERE CONSTRUCTION DUST IS
PRESENT.
REQUIRE THE USE OF "TEMPORARY CONSTRUCTION CONTAINMENT SYSTEMS" THAT
ARE GASKETED AT THE TOP AND BOTTOM TO CREATE AN AIRTIGHT SEAL WHICH
MEETS OR EXCEEDS ICRA CLASS IV REQUIREMENTS AND EXCEEDS ASTM E-84 CLASS A
STANDARDS FOR FLAME AND SMOKE SPREAD.
EXISTING SPRINKLER PROTECTION SHOULD REMAIN ACTIVE WHERE POSSIBLE.
SCHEDULED IMPAIRMENTS AND THEN RETURNED TO SERVICE.
THE EXISTING FIRE ALARM DETECTION AND NOTIFICATION SHALL REMAIN ACTIVE
WHERE POSSIBLE.
SCHEDULED IMPAIRMENTS AND THEN RETURNED TO SERVICE, POSSIBLY CHANGE
SMOKE DETECTORS TO HEAT DETECTORS FOR DURATION OF CONSTRUCTION.
PROVIDE OPTION TO CHANGE SMOKE DETECTORS TO HEAT DETECTORS DURING
DURATION OF CONSTRUCTION.
FIRE ALARM SYSTEM INSTALLATION SHOULD BE COORDINATED AND PLACED IN
SERVICE PRIOR TO FINAL INSPECTION.
MEANS OF NOTIFICATION REQUIRED THROUGHOUT CONSTRUCTION AREAS (NFPA 241
REQUIREMENT)
TEMPORARY SYSTEM MAY BE DESIRED IF THE NEW SYSTEM CANNOT BE INSTALLED AS
CONSTRUCTION PROGRESS.
ONCE INSTALLED, THE SYSTEM SHOULD BE ON EVEN IF PENDING ACCEPTANCE.
ARCHITECTURAL GENERAL NOTES
A. DIMENSIONS, UNLESS OTHERWISE INDICATED, ARE TO:
• FACE OF EXISTING WALL SURFACE
• FACE OF NEW MASONRY
• FACE OF NEW WALL STUDS
• TOP OF SLAB
• TOP OF MASONRY
• ALIGN NEW WALL WITH EXISTING WHERE NOT OTHERWISE INDICATED.
B. COORDINATE WITH ALL DISCIPLINES DOCUMENTS FOR ADDITIONAL REQUIREMENTS.
COORDINATE OPENINGS IN SLABS, ROOF, AND WALLS. WHERE NEW HOLES IN EXISTING
WALLS AND SLABS ARE CREATED FOR PENETRATIONS, COORDINATE SIZE AND LOCATION.
PATCH HOLES CAUSED BY THE REMOVAL OF EQUIPMENT, PIPING, CONDUIT, DUCT,
GRILLES, ETC. WITH MATERIALS MATCHING EXISTING SLAB OR WALL IN STRUCTURE,
MATERIAL, THICKNESS, ALIGNMENT, GRADES, AND QUALITY.
C. COORDINATE AND PROVIDE GALVANIZED METAL BACKER PLATE OR SOLID FIRE
RETARDANT TREATED WOOD BLOCKING FOR WALL-MOUNTED ITEMS. COORDINATE
LOCATIONS WITH COR FOR GOVERNMENT PROVIDED/CONTRACTOR INSTALLED
EQUIPMENT.
D. `PROVIDE' IS DEFINED AS PROVIDING MATERIALS, DELIVERY, STORAGE, HANDLING,
INSTALLATION, ADJUSTMENT, AND CLEANING FOR THE ITEM INDICATED.
E. SEAL PIPE PENETRATIONS THROUGH SLABS, MASONRY, SMOKE RATED PARTITIONS AND
FIRE-RATED PARTITIONS WITH THE APPROPRIATE FIRESTOP TO MAINTAIN THE RATING OF
THE WALL OR SLAB. SUBMIT CUT SHEETS AND SPECIFICATIONS TO THE COR FOR
APPROVAL PRIOR TO INSTALLATION. PROVIDE UL LISTED ASSEMBLES.
F. SKIM COAT ALL DAMAGED EXISTING WALL SURFACES THAT REQUIRE PAINTING.
G. REMOVE MATERIALS WHICH ARE INDICATED TO BE TURNED OVER TO THE COR SHALL BE
DELIVERED BY THE CONTRACTOR TO A PLACE INDICATED BY THE COR.
H.
I.
REMOVE COMPLETELY ALL MATERIALS AS INDICATED ON THE DRAWINGS AND
AS REQUIRED FOR NEW CONSTRUCTION. EDGES AND FACES OF DEMOLISHED AREAS
HALL BE REPAIRED TO ACCEPT NEAT INSTALLATION OF NEW CONSTRUCTION OR
FINISHES . WHERE EXISTING MATERIALS ARE TO BE REPLACED (WALLS, INSULATION,
FLOORING, ETC.) EXISTING MATERIALS, ADHESIVES, ETC. SHALL BE REMOVED AND
EXPOSED SURFACES SHALL BE PREPARED AS INDICATED OR SPECIFIED PRIOR TO
INSTALLATION OF NEW MATERIALS.
PREVENT DAMAGE TO MATERIALS AND FINISHES TO REMAIN. REPAIR DAMAGES FROM
CONSTRUCTION ACTIVITIES TO EXISTING ITEMS TO REMAIN, AT NO ADDITIONAL COST
WHERE SUCH EXPOSED MATERIALS OR FINISHES TO REMAIN ARE DAMAGED.
FIRE PROTECTION DEMOLITION NOTES
1. THESE NOTE ARE APPLICABLE TO THE FULL SET OF CONTRACT DRAWINGS.
2. EXISTING CONDITIONS ARE TAKEN FROM FILED OBSERVATIONS AND PRIOR
CONSTRUCTION DOCUMENTS WHEN AVAILABLE. THE LOCATIONS SHOWN MUST
BE CONSIDERED APPROXIMATE. OTHER SUCH WORK MAYEXIST, HOWEVER,
LOCATION AND SIZE ARE NOT PRESENTLY KNOW.
3. WHEN EXISTING CONSTRUCTION IS DAMAGED DURING WORK BY THIS
CONTRACTOR, REPAIN AND/OR REPLACE WITH SIMILAR OR LIKE MATERIALS AS
MUCH AS POSSIBLE, SUBJECT TO THE FUND AND ARCHITECTURAL APPORVAL.
4. DISPOSE OF ALL DEMOLITION AND/OR OTHER WASTE MATERIALS CAUSED BY
WORK OF THIS CONTRACTOR. LEGALLY DISPOSE ALL MATERIALS TO A
LOCATION OFF SITE.
5. ALL EXISTING PIPPING TO BE REMAIN SHALL BE RECONNECTED TO ACTIVE
SERVICE PIPING.
6. ALL PIPPING TO BE REMOVED SHALL BE REMOVED BACK TO THE ACTIVE
PIPPING AND CAPPED.
7. ALL PIPPING TO BE REMOVED THAT IS LOCATED WITHIN A WALL TO REMAIN MAY
BE ABANDONED IN PLACE PROVIDING THE PIPPING IS INACTIVE. NO DEAD LEGS
PERMITTED. REMOVE THE INACTIVE PIPPING BACK TO BEHIND THE FINISHED
WALL SURFACE AND CAPPED.
8. PATHCH HOLES IN EXISTING CONSTRUCTION LEFT BY THE REMOVAL OF PIPING
OR EQUIPMENT. MAINTAIN THE FIRE/SMOKE RATING OF THE EXSITING
CONSTRUCTION.
9. DEMOLITION SHALL INCLUDE, BUT NOT LIMITED TO: PIPING, VALVES,
EQUIPMENT, HANGERS, SUPPORTS, SPRINKLER HEADS, AND LEGAL DISPOSAL
OFF SITE.
10. ALL PIPING SYSTEMS THAT PASS THROUGH TE AREA OF WORK, WHICH SERVED
SPACES OUTSIDE OF THE AREA OF WORK, SHALL BE KEPT FULLY OPERABLE
DURING CONSTRUCTION. SHUT DOWN OF THESE PIPING SYSTEMS FOR THE
PUPOSE OF RE-ROUTING AND RECONNECTION SHALL BE SCHEDULED WITH THE
OWNER'S REPRESENTATIVE FIVE WORKING DAYS IN ADVANCE. NEW PIPING
SHALL BE PRE-INSTALLED, TESTED, AND READY FOR CONNECTION INA MANNER
TO ALLOW FOR A PRE-SCEDULED ONE DAY SHUTDOWN.
R. LOCATE EXISTING SLAB REINFORCING(TOP AND BOTTOM) THROUGH NON-
DESTRUCTIVE MEANS PRIOR TO SUBMISSION OF PIPING LAYOUT SHOP DRAWINGS FOR
REVIEW. DO NOT CUT EXISTING REINFORCING(TOP OR BOTTOM) OF SLAB DURING
PENETRATION INSTALLATION. COORDINATE PLUMBING PENETRATIONS WITH
PLUMBING.
J. CONTRACTOR SHALL REMOVE ALL THE EXISTING GYP BOARD TO THE EXISTING STUDS.
METAL STUDS WILL BE RPLACED IF DAMAGED OR REQUIRED DURING CONSTRUCTION.
MOUNTING HEIGHTS
PROVIDE BLOCKING AT ALL WALL MOUNTED EQUIPMENT AND ACCESSORIES.
(NOT ALL ITEMS ARE INCLUDED IN THE WORK)
ACCESSIBILITY REQUIREMENTS
FRONT APPROACHES
HINGE-SIDE APPROACHES
LATCH-SIDE APPROACHES
USE EITHER
OPTION 1 OR
OPTION 2
ALL DOOR ASSEMBLIES SHALL BE CONSTRUCTED TO MEET THE
INDICATED MINIMUM CLEARANCES AS APPLICABLE.
1'-0" IF DOOR HAS BOTH
A CLOSER AND A
LATCH
5' -0
1'-6"
3' -6
4'-6"
4' -0
O P
TI
O
N
5' -0
OPTION 1
3'-0"
O P
TI
O
N
4' -6
OPTION 2
3'-6"
2'-0"
4' -0
2'-0"
3' -6
4' -0
4' -6
W / C
LO
S
E R
4' -0
W / C
LO
S
E R
W /C
LO
S
E R
A N
D L
A
TC
H
ALL WORK SHALL COMPLY WITH FEDERAL ABA,
LOCAL, AND STATE ACCESSIBILITY CODES AND
REQUIREMENTS.
DOOR LOCATIONS
TYPICAL DETAILS
TYP DOOR LOCATION
SEE DOOR SCHEDULE
4"
TYP
TYP. HANDRAIL / CRASH
RAIL ELEVATION
CRASH RAIL
HANDRAIL/WALL
GUARD RETURN
TO WALL @ END
4"4"
1'
2"
BASE AS SCHEDULED
CORNER GUARD
DOOR FRAME
OR OPENING
3' -0
M
A X
4"
1'
2"
4" TO INSIDE
CORNER
3'
4"
4'
" T Y
P 3'
4"
H C
2'
9"
2'
6" 3'
8"
CL
CL
FIRE
EXTINGUISHER
CABINET
MIRROR TYP
DF/EWC
HC
DF/EWC
GARMENT
HOOK
M
IN
3' - 0"MAX
2'
9" M
IN
3'
0" M
A X
-1
1' - 0"3' - 6"
SANITARY
NAPKIN
DISPOSAL
GRAB BAR
TP
DISPENSER
6" 3' - 0"
GRAB BAR
SEAT COVER
DISPENSER
MIRROR
4'
0"
2'
9" M
IN
3'
0" M
A X
1' - 6" 1' - 6"
3'
4" H
C
TYP TOILET ROOM
SHOWER
HEAD
SHOWER
CONTROL
GRAB BAR
RECESSED
SOAP DISH
GRAB BAR
2'
9" M
IN
3'
0" M
A X
3'
4"
2'
9" M
IN
3'
0" M
A X
EQ EQ
7'
0"
2'
9" M
IN
3'
0" M
A X
4'
0" M
A X
EQ EQ
TYP SHOWER
SOAP DISPENSER
PAPER
TOWEL
DISPENSER
3'
5"
3'
6"
SOAP
DISPENSER
2'
3' -0
M
A X
SS
SHELF
6'
6"
POSTURE
MIRROR
VA FORM 08-6231
1 2 3 4 5 6 7 8 9
Date:
Drawing Title:
Approved Project Director
Project Title:
1 2 3 4 5 6 7 8 9
FINAL CONTRACT
SUBMITTAL590 MEANS ST NW
Phase Project Number
Building Number
Drawing NumberLocation
Issue Date CheckedFULLY SPRINKLERED
STAMP
STE. 200
ATLANTA, GA 30318
ARCHITECT/ENGINEER OF RECORDCONSULTANT
A
B
C
D
E
F
U.S. Department of Veterans Affairs
Office of Construction and
Facilities Management
Drawn
1 & 12
SJ/EO/SMTS
573-20-604
GENERAL NOTES, DETAILS,
ABBREVIATIONS AND LEGENDS
RENOVATE COMMON AREA
RESTROOMS
GAINESVILLE, FLORIDA
G002 03-21-2024 smittal Snapshot smittal Image smittal
UP
A
B
C
D
E
F
G
H
J
K
L
M
N
P
R
123478910111213141516
ES
JN
8w
R.4
An
1'
4"
ELEVATOR
GAS
STORAGE
C077A-1
GAS
STORAGE
C077-1
ELEC
C073A-1
ELEC
A026-1
HAC
A025-1
RADIO
ISOTOPE
STORAGE
A020-1
TOILET
A021-1
CT SCAN
A018-1
STORAGE
A015-1
NUCLEAR
MAGNETIC
RESONANCE
A022-1
ELEC
A023A-1
CONTROL
A013-1
CAMERA
IMAGING
A016-1
VEST
A006-1
X-RAY
READING
A002-1LAB
A01-1
OFFICE
A01A-1
OFFICE
D125-1
LAB
D124-1
LAB
D121-1
STORAGE
D120-1
LAB
D117-1CARDIOVASCULAR
RESEARCH
LAB
D116-1
LAB
D112-1
CLEAN
ROOM
D110B-1
AUTOPSY
D095-1
OFFICE
D109-2
BIO-MED.
D111-1
BIO-MED
D110A-1
RESEARCH
COMMON
RESOURCE
D113-1 LAB
D114-1
LAB
D107A-1
HAC
D115-1
ELEC
D116B-1
COUNTING
ROOM
D116A-1
WATER
D119-1
DARK
ROOM
D119A-1
RESEARCH
COMMON
RESOURCE
D122-1
SURGERY
ANIMAL
D123-1
MILLION
VETERANS
PROGRAM
A063-1
OFFICE
A061-1
MICROSCOPE
A062-1
LAB
A003-1
DEXA SCAN
A004-1
RESTROOM
A220A-1
INJECTION
ROOM
A010-1
STER. PROC.
D104-1
LAB
D103-1
LAB
D102-1
STORAGE
D107-1
LAB
D105-1
LAB
D106-1
BREAK
ROOM
A005-1
NUCLEAR
MEDICINE
OFFICE
A011-1
STORAGE
A060B-1
ELECTRON
MICROSCOPE
A060-1
SPD.
STORAGE
A059-1
DATA
A027-1
CREDIT
UNION
A031-1
CREDIT
UNION
A031A-1
BREAK
ROOM
A032-1
WOMENS
LOUNGE
B033-1
STAFF
WOMENS
LOCKER
B055-1
STAFF
WOMENS
TOILET
A056-1
STAFF MENS
TOILET
A057-1
CONFERENCE/CLASSROOM
A030-1
STORAGE
A036B-1
VISITOR
WOMENS
TOILET
B035-1
VISITOR
MENS
TOILET
B034-1
RESEARCH
OFFICE
A024B-1 VEST
A024-1
VOLUNTEER
STORAGE
A024A-1
STORAGE
A029-1
AUDITORIUM
A036-1
OFFICE
B038-1
RECREATION
THERAPIST
OFFICE
B037-1
RECREATION
THERAPIST
OFFICE
B039-1
STORAGE
B039A-1
VEST
CB-6A
STORAGE
B040-1
HAC
B041-1
RETAIL
STORE
B046-1
VENDING
B065-1
SERVICE
ELEVATOR
LOBBY
C067-1
HAC
C069-1
DATA
C070-1
PATIENT
STORAGE
C071-1
CLEAN LINEN
DISTRIBUTION
C080B-1
COMPRESSOR
ROOM
C073-1
SEAMSTRESS
ROOM
C081-1
OFFICE
C083-1
OFFICE
C084-1
LOCKSMITH
C085A-1
REFRIGERATION
SHOP
C085-1
EMS
TRAINING
ROOM
C079-1 DIETICIAN
OFFICE
C068F-1
FREEZER
C059-1
REFRIGERATOR
C058-1
MEAT
FREEZER
C056-1
HAC
C068B-1
MAIN
ELECTRICAL
ROOM
D089-1
ESSENTIAL
SYSTEMS
ROOM
C087-1
ENGINEERING
PAINT SHOP
C086-1
STORAGE
C086B-1
SPS
SECRETARY
D092-1
ELEC
D093A-1
WOMENS
STAFF
TOILET
D093-1
MENS STAFF
TOILET
D094-1
FOREMAN
C068D-1
OFFICE
C064-1
OFFICE
B0491-1
B0468-1
CANTEEN
B049-1
VEGETABLE
PREPARATION
C068A-1
ELEC
B054G-1
OFFICE
B054C-1
STORAGE
B054A-1
MAIN
KITCHEN
C068-1OFFICE
C068E-1
STORAGE
C076-1
REFRIGERATOR
C060-1
ELEVATOR A
CB-9
SOILED
LINEN
D072-1
OFFICES
D100A-1
LAB
D101A-1
CLINICAL
RESEARCH
ELE. TECH
LAB
D101-1
ELECTRIC
SHOP
C086A-1
MACHINE
ROOM
C080C-1
OFFICE
C080A-1
HAC
D100U-1
RECEIVING
DECONTAMINATION
D100E-1
HAC
D100K-1
CART WASH
D100D-1
STERILIZATION
ROOM
D100L-1
HAC
D100R-1
MENS
TOILET
D100Q-1
WOMENS
TOILET
D100P-1
OFFICE
D099-1
CHIEF
D099A-1
OFFICE
D099B-1
CLEAN
RECEIVING
AREA
D100M-1
PREPARATION
AREA
D100N-1
SUPPLY
PROCESSING
AND
DISTRIBUTION
D100-1
SHOWER
D100G-1
TOILET
D100H-1
VEST
D100F-1
AUTOPSY
SUPPLY
D095A-1
TOILET
D095B-1
OFFICE
D108A-1
RESEARCH
INVESTIGATOR
D108-1
COLD ROOM
D095C-1
COMMON
RESEARCH
D096-1
LAB
D123A-1
LAB
A062A-1
STORAGE
D091-1
FILM
STORAGE
C080D-1
OFFICE
A060A-1
STORAGE
A026C-1
CREDIT
UNION
A031B-1
STORAGE
A036C-1
VENDING
B065A-1
DIET. TECH.
B050C-1
CORRIDOR
xxx
DIET SECY.
B050-1
CHIEF
DIETETICS
OFFICE
B050A-1
SOCIAL
WORK
B032A-1
VACANT
OFFICE
A030C-1
STORAGE
B054E-1
OFFICE
B054B-1
CLASSROOM
B054F-1
COFFEE
SHOP
B049J-1
NUTRIENT &
FOOD
SERVICES
C068C-1
DAIRY
REFRIGERATOR
C057-1
VEGETABLE
FREEZER
C055-1
STORAGE
B054D-1
FOOD STOCK
ROOM
B049H-1
FOOD
PREPARATION
AREA
B049C-1
CORRIDOR
A156-205
CORRIDOR
A156-206
RETAIL
RECEIVING
SECURE
STORAGE
B0498-1
OFFICE
B046D-1
OFFICE
B049E-1
STOCKROOM
B047-1
OFFICE
D114A-1
STORAGE
D100O-1
MECH
D100B-1
EQUIPMENT
SPD
D100C-1
SCANNER
ROOM
A019-1
CONTROL
A017-1
CONTROL
A014-1
CLOSET
EB52A-1
STAFF MENS
LOCKERS
A058A-1
STER. PROC.
SOILED
SCOPE
D104A-1
TOILET
A017A-1
WAITING
A012-1
DINING
ROOM
B049F-1
FEC
B-4-1
FEC
B-7-1
ELEC
C068H-1
FEC
B-9-1
DISH
WASHING
C480-1
DATA
C068G-1
PATIENTS
DINING
ROOM
B054-1
FEC
B-6-1
FEC
B-11-1
STORAGE
B048-1
STAGE
A036A-1
FEC
B-5-1
CLOSET
A024C-1
CLOSET
A024D-1
DATA
A026B-1
DATA
A026A-1
LOUNGE
A058-1
MECH
A059A-1
TRAYV.
D1001-1
LAUNDRY
SHOOT
D072A-1
ANTE ROOM
D100T-1
OFFICE
C086C-1
DATA
D098-1
STORAGE
D098A-1
FEC
B-14-1
FEC
B-13-1
CLOSET
A019A-1
CT SCAN
A023-1
EXAM
A009-1
FEC
B-2-1
STORAGE
D109A-1
ELEVATOR
D109-3
ELEVATOR
D109-4
ELEVATOR
D109-5
ELEVATOR
D109-6
ELEVATOR
D109-7
ELEVATOR
D109-8
STAIR
3-0
STAIR
2-0
STAIR
1-0STAIR
4-0
OFFICE
A006B-1
CHIEF
TECHNOLOGIST
A006A-1
OFFICE
A006C-1
LACTATION
ROOM
B055A-1
OFFICE
B050B-1
SPS NURSE
D092A-1
OFFICE
C080E-1
CORRIDOR
C080F-1
OFFICE
C080-1
ELEC
D109-9
ELEC
D109-10
MECH
B049K
CARBINATION
STORAGE
D109-11
TRANSFORMER
ROOM
C126-1
SWITCHGEAR
ROOM
C126A-1
TLT
D109-16
OFFICE
D109-15
BOILER
ROOM
D109-14
STORAGE
C078F-1
GRAPHICS
CONTROL
C078E-1
AIR
CONDITIONING
EQUIPMENT
CONTROL
ROOM
C078-1
MECH
C078D-1
LOCKER
ROOM &
BATH
C078G-1
CORRIDOR
D109-17
TYP
6 5
TYP
TYP
D A
C B
EF
G
KEY PLAN
TRUE
NORTH
PLAN
NORTH
DEMO PLAN GENERAL NOTES
A. CONTRACTOR SHALL GUT AND REMOVE ALL EXISTING CONSTRUCTION DOWN TO EXISTING STUDS/ STRUCTURE REQUIRED TO INSTALL NEW WORK AND SHALL DISPOSE OF ALL DEMOLISHED MATERIALS IN
AN APPROVED, OFFSITE LANDFILL EXCEPT WHERE OTHERWISE REQUIRED FOR SALVAGE OR
RECYCLING.
B. CONTRACTOR SHALL DEMOLISH ALL EXISTING MILLWORK, TOILET ACCESSORIES, GRAB BARS, COUNTERTOPS, AND TOILET PARTITIONS IN AREA OF WORK.
C. REFER TO AND COORDINATE WITH OTHER DICSIPINES DRAWINGS AND DOCUMENTS FOR ADDITIONAL
INFORMATION AND INSTRUCTIONS.
D. REMOVE AND STORE EXISTING SIGNAGE FOR REINSTALLATION.
E. DEMOLISH EXISTING FLOORING & BASE INCLUDING FLOORING UNDERLAYMENT IN AREA OF WORK AS
NEEDED TO INSTALL NEW WORK.
EXISTING DOOR, HARDWARE AND FRAME ASSEMBLY TO REMAIN. PREPARE SURFACE FOR NEW FINISH.
DEMO FLOOR PLAN KEY NOTES #
2 DEMOLISH EXISTING LOCKERS AND BENCHES.
3 DEMOLISH EXISTING WALL & FLOOR EXPANSION JOINT COVER IN AREA OF WORK AS INDICATED.
4 DEMOLISH EXISTING DOOR, FRAME ASSEMBLY AND HARDWARE AS INDICATED.
5 REMOVE EXISTING EQUIPMENT, RELOCATE AND STORE AT A APPROVED LOCATION FOR
REINSTALLATION.
DEMO PLAN LEGEND
EXISTING CONSTRUCTION
TO REMAIN
EXISTING CONSTRUCTION TO BE
DEMOLISHED
2-HOUR FIRE BARRIER
1-HOUR FIRE BARRIER
AREA OF WORK
VA FORM 08-6231
1 2 3 4 5 6 7 8 9
Date:
Drawing Title:
Approved Project Director
Project Title:
1 2 3 4 5 6 7 8 9
FINAL CONTRACT
SUBMITTAL590 MEANS ST NW
Phase Project Number
Building Number
Drawing NumberLocation
Issue Date CheckedFULLY SPRINKLERED
STAMP
STE. 200
ATLANTA, GA 30318
ARCHITECT/ENGINEER OF RECORDCONSULTANT
A
B
C
D
E
F
U.S. Department of Veterans Affairs
Office of Construction and
Facilities Management
Drawn
1 & 12
SJ/EO/SMTS
573-20-604
OVERALL BASEMENT DEMO PLAN -
AREA A, B, C & D
RENOVATE COMMON AREA
RESTROOMS
GAINESVILLE, FLORIDA
AD101
03-21-2024
1/16" = 1'-0"AD101
1 OVERALL BASEMENT DEMO PLAN - AREA A,B,C &D
SCALE:
0' 8' 16' 32' 48'
1/16" = 1' - 0" smittal Snapshot smittal Image smittal
B
C
D
E
F
G
H
J
K
L
25 24 23 22 21.2 20 19 18 17 16
D1
E1
K5
M
20.221.4
15 14
2710 SF
UPPER
MECHANICAL
ROOM
EB60-1
85 SF
OFFICE
EB62A-1
45 SF
FIRE ALARM
CLOSET
EB62-1
40 SF
ELEC
EB61-1
178 SF
ASST. CHIEF
HIMS
EB58-1
132 SF
OFFICE
EB56A-1
683 SF
VAVS &
STORAGE
EB55-1
456 SF
RELEASE OF
INFORMATION
EB54-1
238 SF
CHIEF HIMS
EB57B-1
88 SF
OFFICE
EB53-1
76 SF
OFFICE
EB54A-1
90 SF
OFFICE
EB52-1
275 SF
OFFICE
EB51-1
304 SF
OFFICE
EB32-1
166 SF
OFFICE
EB32B-1
84 SF
HAC
EB01-1
180 SF
MAIL ROOM
EB02-1
56 SF
FLAMMABLE
STORAGE
EB64-1
54 SF
FLAMMABLE
STORAGE
EB63-1
104 SF
MENS
TOILET
EB03-1
100 SF
WOMENS
TOILET
EB04-1
113 SF
OFFICE
EB06-1
101 SF
OFFICE
EB07-1
136 SF
OFFICE
EB09-1
22 SF
HAC
EB11-1
103 SF
OFFICE
EB12-1
104 SF
EXAM
EB14-1
21 SF
SOILED
STORAGE
EB16A-1
114 SF
WORK ROOM
EB13-1
319 SF
RECEPTION
EB18A-1
122 SF
EXAM
EB25-1
123 SF
EXAM
EB20-1
141 SF
OFFICE
EB19-1
42 SF
ELEC
EB08-1
184 SF
AUDIOLOGY
EXAM ROOM
EB26-1
90 SF
LOUNGE
EB27-1
202 SF
STAIR
6-B-1
92 SF
SPEECH
PATHOLOGY
OFFICE
EB34-1
92 SF
CHIEF
AUDIOLOGY
EB33-1
25 SF
HAC
EB35-1
28 SF
ELEC
EB47-1
99 SF
MENS
TOILET
EB46-1
93 SF
WOMENS
TOILET
EB45-1
127 SF
SPEECH
LANGUAGE
PATHOLOGIST
EB44-1
79 SF
APHASIA
EB43-1
101 SF
EXAM
EB42-1
74 SF
SPEECH
PATHOLOGY
OFFICE
EB41-1
147 SF
RECEPTION
EB36A-1
98 SF
OFFICE
EB37-1
193 SF
EXAM
EB40-1
115 SF
GROUP
THERAPY
EB39-1
76 SF
OFFICE
EB38-1
169 SF
TREATMENT
EB24-1
107 SF
EXAM
EB16-1
148 SF
TREATMENT
EB15-1
147 SF
SOUND TEST
EXAM
EB36E-1
156 SF
OFFICE
EB28-1
70 SF
UTLILTY
CLOSET
EB05-1
357 SF
WAITING
EB36-1
360 SF
STORAGE
EB81-1
302 SF
LAB
EB71-1
566 SF
STORAGE
EB67-1
790 SF
UPPER
TRANSFORMER
ROOM
EB66-1
498 SF
UPPER
GENERATOR
ROOM
EB65-1
255 SF
STAIR
7-1
9 SF
DATA
EB32A-1
618 SF
CORRIDOR
E213-70
369 SF
CORRIDOR
E213-71
458 SF
CORRIDOR
E213-72
623 SF
CORRIDOR
E213-73
193 SF
ELEVATOR B
E213-74
154 SF
CORRIDOR
E213-75
1688 SF
CORRIDOR
782 SF
CORRIDOR
EB68-1
42 SF
STORAGE
EB67B-1
78 SF
ELEVATOR
79 SF
ELEVATOR
76 SF
ELEVATOR
70 SF
ELEVATOR
1442 SF
PHARMACY
STORAGE
EB59D-1
472 SF
CONFERENCE
ROOM
EB91-1
455 SF
CLASSROOM
EB59B-1
784 SF
STORAGE
EB84-1
91 SF
SUPPLY
GENERAL
ENGI.
EB86-1
110 SF
TOILET
EB94-1
109 SF
TOILET
EB95-1
173 SF
COPY ROOM
EB93-1
113 SF
OFFICE
EB59G-1
87 SF
OFFICE
EB59F-1
98 SF
ARCHITECT
EB59E-1 1258 SF
ENGINEERING
EB59-1
92 SF
INDUSTRIAL
HYGENIST
EB59H-1
99 SF
OFFICE
EB59I-1
162 SF
VACANT
EB59A-1
125 SF
ENGIN. TECH
#4
EB59C-1
113 SF
ENGIN. TECH
#3
EB96-1
117 SF
ENGIN. TECH
#2
EB92-1
108 SF
ENGIN. TECH
#1
EB90-1
98 SF
SUPER.
GENERAL
ENGINEER
EB89-1
124 SF
ACCT. TECH.
EB88-1
117 SF
RECEPTION
EB105-1
136 SF
RECEPTION
EB103-1
108 SF
DIVISION
CHIEF
EB101-1
118 SF
ENERGY
ENGINEER
EB99-1
114 SF
SAFETY
OFFICER
EB97-1
145 SF
TRANSPORTATION
COORDINATOR
EB98-1
152 SF
SAFETY
SPECIALIST
EB100-1
109 SF
KITCHEN
EB102-1
159 SF
SYSTEM
CHIEF
ENGIN.
SERV.
EB104-1
371 SF
CONFERENCE
ROOM
EB106-1
610 SF
CARPENTER
EB29-1
107 SF
EXAM
EB17-1
111 SF
EXAM
EB23-1
17 SF
STORAGE
EB10-1
30 SF
CLEAN
STORAGE
EB16B-1
110 SF
NURSE
STATION
EB21-1
98 SF
OFFICE
EB38A-1
53 SF
SOUND
ROOM
EXAM
EB360-1
50 SF
SOUND
ROOM EXAM
EB36F-1
97 SF
EXAM
EB39A-4
123 SF
EXAM
EB76-1
145 SF
SOUND
ROOM EXAM
EB36C-1
60 SF
OFFICE
EB73-1
90 SF
OFFICE
EB72-1
88 SF
OFFICE
EB70-1
63 SF
OFFICE
EB69-1
299 SF
LAB
222 SF
CORRIDOR
EB36B-1
116 SF
EXAM
EB75-1
126 SF
EXAM
EB74A-1
284 SF
OFFICE
EB77-1
178 SF
CONFERENCE
ROOM
EB79-1
107 SF
COLD ROOM
EB82-1
53 SF
TOILET
EB78-1
91 SF
CLEAN
ROOM
EB80B-1
730 SF
BIO-MED.
SHOP
EB80-1
97 SF
OFFICE
EB80A-1
81 SF
DATA
EB80C-1
157 SF
OFFICE
EB55B-1
139 SF
OFFICE
EB55A-1
130 SF
BREAK
ROOM
EB55C-1
155 SF
OFFICE
EB56-1
85 SF
OFFICE
EB62B-1
174 SF
OFFICE
EB55D-1
227 SF
EB01A-1
61 SF
FILES
EB29B-1
72 SF
STORAGE
EB29A-1
121 SF
OFFICE
EB51A-1
135 SF
OFFICE
EB49-1
59 SF
TRAVEL
OFFICE
44 SF
DATA
EB57A-1
125 SF
OFFICE
EB57-1
158 SF
STORAGE
EB85-1
155 SF
EB67A-1
212 SF
STAIR
5-1
135 SF
CORRIDOR
6 SF
CLOSET
EB23A-1
156 SF
EXAM
EB74-1
49 SF
ELEVATOR B
TRUE
NORTH
PLAN
NORTH
D A
C B
EF
G
DEMO GENERAL NOTES
A. CONTRACTOR SHALL GUT AND REMOVE ALL EXISTING CONSTRUCTION DOWN TO EXISTING STUDS/ STRUCTURE REQUIRED TO INSTALL NEW WORK AND SHALL DISPOSE OF ALL DEMOLISHED MATERIALS IN
AN APPROVED, OFFSITE LANDFILL EXCEPT WHERE OTHERWISE REQUIRED FOR SALVAGE OR
RECYCLING.
B. CONTRACTOR SHALL DEMOLISH ALL EXISTING MILLWORK, TOILET ACCESSORIES, GRAB BARS, COUNTERTOPS, AND TOILET PARTITIONS IN AREA OF WORK.
C. REFER TO AND COORDINATE WITH OTHER DICSIPINES DRAWINGS AND DOCUMENTS FOR ADDITIONAL
INFORMATION AND INSTRUCTIONS.
D. REMOVE AND STORE EXISTING SIGNAGE FOR REINSTALLATION.
E. DEMOLISH EXISTING FLOORING & BASE INCLUDING FLOORING UNDERLAYMENT IN AREA OF WORK AS
NEEDED TO INSTALL NEW WORK.
DEMO FLOOR PLAN KEY NOTES #
1 EXISTING DOOR, HARDWARE AND FRAME ASSEMBLY TO REMAIN. PREPARE SURFACE FOR NEW FINISH.
0' 4' 8' 16' 24'
SCALE: 3/32" = 1'-0"
32'
DEMO PLAN LEGEND
EXISTING CONSTRUCTION
TO REMAIN
EXISTING CONSTRUCTION TO BE
DEMOLISHED
2-HOUR FIRE BARRIER
1-HOUR FIRE BARRIER
AREA OF WORK
VA FORM 08-6231
1 2 3 4 5 6 7 8 9
Date:
Drawing Title:
Approved Project Director
Project Title:
1 2 3 4 5 6 7 8 9
FINAL CONTRACT
SUMBITTAL590 MEANS ST NW
Phase Project Number
Building Number
Drawing NumberLocation
Issue Date CheckedFULLY SPRINKLERED
STAMP
STE. 200
ATLANTA, GA 30318
ARCHITECT/ENGINEER OF RECORDCONSULTANT
A
B
C
D
E
F
U.S. Department of Veterans Affairs
Office of Construction and
Facilities Management
Drawn
1 & 12
SJ/EO/SMTS
573-20-604
OVERALL BASEMENT DEMO PLAN -
AREA E
RENOVATE COMMON AREA
RESTROOMS
GAINESVILLE, FLORIDA
AD102
03-21-2024
3/32" = 1'-0"AD102
1 OVERALL BASEMENT PLAN - AREA E
KEY PLAN E
smittal Snapshot smittal Image smittal
26272829303132
B.2
C.2
D.2
E.2
E.7
F.5
G.7
J
K.3
M
M.6
N
E.8 j k l
ELEVATOR
S-12
ELEVATOR
S-11
REC. REV
FB23A-1
MAS
RECORDS/WK
AREA
FB23-1
FAC./BODY
STUDIO
FB11-1
ORTHO LAB
FB09-1
OFFICE
FB07-1
CORRIDOR
F-CB-4
OFFICE
FB08-1
OFFICE
FB16-1
OFFICE
FB16A-1
HAC
FB13-1
DATA
FB14-1
CORRIDOR
F-CB-6
CORRIDOR
F-CB-3
BRAIN
REHAB
RESEARCH
DEPARTMENT
FB06-1
OFFICE
FB05-1
MENS
TOILET
FB03C-1
MENS
LOCKER
ROOM
FB03B-1
VEST
FB03A-1
WOMENS
TOILET
FB02C-1
WOMENS
SHOWER
FB02D-1
WOMENS
LOCKER
ROOM
FB02B-1
VEST
FB02A-1
LOUNGE
FB01-1
HAC
FB04-1
STAIR
7-1
EXIT
CORRIDOR
F-CB-1
DISPENSING
FB15-1APPL.
STOR./MAILOUT
FB17-1
ELEVATOR
FB00-1
TOILET
FB18A-1
ELEC
FB20-1
STORAGE
FB21-1
STORAGE
FB22-1
ELEVATOR
LOBBY
F-CB-8
EXIT
CORRIDOR
F-CB-9
SUPERVISOR
FB25-1
PATIENT
LUGGAGE
FB24-1
COPY ROOM
FB27-1
HAC
FB28A-1
FENCED
STORAGE
FB28D-1
GENERAL
BUILDING
STORAGE
FB26-1
EXIT
CORRIDOR
WAREHOUSE
FB28-1
ELEC
FB30-1
DATA
FB28K-1
ELEC
FB28J-1
FLAMMABLE
GAS
FB31-1
MEDICAL
GAS
FB32-1
MEDICAL
GAS
FB33-1
WOMENS
TOILET
FB28H-1
MENS
TOILET
FB28G-1
DOCK
WAREHOUSE
SUPERVISOR
FB28F-1
CENTER
SUPERVISOR
FB28E-1
STAIR
8-1
OFFICE
FB08A-1
TREATMENT
ROOM
FB18-1
EXAM
FB18B-1
DATA
FB05B-1
OFFICE
FB05C-1
OFFICE
FB05A-1
OFFICE
FB05D-1
COOLERS
FB28B-1
COOLERS
FB28C-1
MENS
SHOWER
FB03D-1
UPPER
MECHANICAL
ROOM
FB29-1
FILE
STORAGE
FB17A-1
OFFICE
GC129-2
Room
GC129-3
Room
GC129-4
OFFICE
GC129-5
BREAK
ROOM
GC129-7
TYP
TYP
D A
C B
EF
G
TRUE
NORTH
PLAN
NORTH
DEMO GENERAL NOTES
A. CONTRACTOR SHALL GUT AND REMOVE ALL EXISTING CONSTRUCTION DOWN TO EXISTING STUDS/ STRUCTURE REQUIRED TO INSTALL NEW WORK AND SHALL DISPOSE OF ALL DEMOLISHED MATERIALS IN
AN APPROVED, OFFSITE LANDFILL EXCEPT WHERE OTHERWISE REQUIRED FOR SALVAGE OR
RECYCLING.
B. CONTRACTOR SHALL DEMOLISH ALL EXISTING MILLWORK, TOILET ACCESSORIES, GRAB BARS, COUNTERTOPS, AND TOILET PARTITIONS IN AREA OF WORK.
C. REFER TO AND COORDINATE WITH OTHER DICSIPINES DRAWINGS AND DOCUMENTS FOR ADDITIONAL
INFORMATION AND INSTRUCTIONS.
D. REMOVE AND STORE EXISTING SIGNAGE FOR REINSTALLATION.
E. DEMOLISH EXISTING FLOORING & BASE INCLUDING FLOORING UNDERLAYMENT IN AREA OF WORK AS
NEEDED TO INSTALL NEW WORK.
EXISTING DOOR, HARDWARE AND FRAME ASSEMBLY TO REMAIN. PREPARE SURFACE FOR NEW FINISH.
DEMO FLOOR PLAN KEY NOTES #
2 DEMOLISH EXISTING LOCKERS AND BENCHES.
0' 4' 8' 16' 24'
SCALE: 3/32" = 1'-0"
32'
DEMO PLAN LEGEND
EXISTING CONSTRUCTION
TO REMAIN
EXISTING CONSTRUCTION TO BE
DEMOLISHED
2-HOUR FIRE BARRIER
1-HOUR FIRE BARRIER
AREA OF WORK
VA FORM 08-6231
1 2 3 4 5 6 7 8 9
Date:
Drawing Title:
Approved Project Director
Project Title:
1 2 3 4 5 6 7 8 9
FINAL CONTRACT
SUBMITTAL590 MEANS ST NW
Phase Project Number
Building Number
Drawing NumberLocation
Issue Date CheckedFULLY SPRINKLERED
STAMP
STE. 200
ATLANTA, GA 30318
ARCHITECT/ENGINEER OF RECORDCONSULTANT
A
B
C
D
E
F
U.S. Department of Veterans Affairs
Office of Construction and
Facilities Management
Drawn
1 & 12
SJ/EO/SMTS
573-20-604
OVERALL BASEMENT DEMO PLAN -
AREA F & G
RENOVATE COMMON AREA
RESTROOMS
GAINESVILLE, FLORIDA
AD103
03-21-2024
3/32" = 1'-0"AD103
1 OVERALL BASEMENT DEMO PLAN - AREA F&G
smittal Snapshot smittal Image smittal
UP
A
B
C
D
E
F
G
H
J
K
L
M
N
P
R
123478910111213141516
ES
JN
2W8w
Ms
R.4
An
OFFICE
A164L-1
OFFICE
A164I-1
OFFICE
A164G-1
OFFICE
A164H-1
CONTROLLED
SUBSTANCE
VAULT
A165-1
MECH.
EQUIP. RM.
C298-1
CARDIAC
OPERATING
ROOM - C
C277-1
OPERATING
ROOM - D
C278-1
SOILED
UTILITY
C279-1
STORAGE
C282A-1
DEVELOPING
ROOM
C282-1
OPERATING
ROOM - B
C289-1
SOILED
HOLDING
C288-1
OPERATING
ROOM - A
C287-1
STORAGE
C282E-1
SCRUB
ROOM
C282D-1
CENTRAL
CORE
HAC
C284-1
MEN
LOCKERS
C283-1
MENS
TOILET
C283A-1
WOMENS
TOILET
C281-1
OFFICE
C268-1
OFFICE
C267-1
OFFICE
C258-1
OFFICE
C257-1
OFFICE
C269-1
OFFICE
C270-1
OFFICE
C251-1
BREAK
ROOM
C250-1
RECEPTION
C271-1
BLOOD
GAS LAB.
C248-1
OFFICE
C274-1
CATH LAB.
C254-1
TOILET
C252-1
CONTROL
ROOM
C254A-1
ELEC
STORAGE
C256-1
CATH. LAB
C255-1
OFFICE
C260-1
OFFICE
C259A-1
OFFICE
C259-1
X-RAY
CONSULTS
C295-1TOILET
C294A-1
X-RAY
ROOM 8
C294-1OFFICE
C297-1
X-RAY
D301-1
ELEC
D311A-1
CHEST
X-RAY
D308-1
FILM
STORAGE
D337-1
X-RAY
DIAGNOSTIC
VII
D300-1
CONTROL
D305A-1
X-RAY
DIAGNOSTIC
I
D305-1
STORAGE
D306-1
TOILET/
STORAGE
D304-1
TOILET
D304A-1
CENTRAL
HAC
B183-1
DOCTOR
B202-1
RECEPTION
B206-1
HAC
B207-1OFFICE
B181-1
STORAGE
B206A-1
OFFICE
B205-1
OFFICE
B204-1
OFFICE
B203-1
OFFICE
B200-1
RECEPTION
B199-1
STORAGE
B222B-1
STORAGE
B222A-1
WHIRLPOOL
TANK RM
B216-1
CHIEF O.T.
B220-1
P.T.
TREATMENT
ROOM
B222-1
PHYSICAL
THERAPY
B221-1
CORRECTIVE
THERAPY
B235-1
OFFICE
B235A-1
ELEC
CHAPLAIN
SERVICE
B229-1
EUCHARISTIC
B228-1
ADMIN
OFFICER
B217-1
EMG. LAB.
B223-1
HAC
B224-1
ADL ROOM
B226-1
MENS
TOILET
B234-1
WOMENS
TOILET
B233-1
OFFICE
B232-1
OFFICE
B231-1
CHAPEL
B230-1
OT WORK
ROOM
B219-1
REHAB. MED.
RECEPTION
B218-1
STAFF
PSYCHIATRIST
B214-1
STORAGE
A125A-1
OFFICE
B139B-1
GENERAL
/SURGERY
RECEPTION
B139-1
OFFICE
B138A-1
OFFICE
A140A-1
SURGERY
OFFICE
A140-1
CONFERENCE
ROOM
B209-1
WAITING
B208-1OFFICE
B144-1
SOCIAL
WORKER
B190-1
OFFICE
B142-1
SERVICE
LOBBY
TRASH
C262-1
SURGICAL
PATHOLOGY
C264-1
OFFICE
C285A-1
CYSTO 1
C265A-1
GENITO
URINARY
CLINIC
C197-1
CYSTO 1
C198-1
TOILET
C199-1
CLERKS
STATION
C265-1
SUPPLY
D335A-1
OFFICE
D363A-1
X-RAY
C203-1
EXAM
C204-1
STORAGE
D169-1
SOILED
UTILITY
D171-1
EXAM 9
D168-1
WOMENS
TOILET
A145-1
MENS
TOILET
A144-1
OFFICE
A147-1
PARALYZED
VET OF
AMERICA
A141-1
OFFICE
WOMENS
TOILET
A127-1
MENS
TOILET
A126-1
OFFICE
A129-1
OFFICE
A130-1
OFFICE
A133-1
OFFICE
A134A-1
EXECUTIVE
CONFERENCE
& M.I.C.
A125-1
HAC
A123-1
CHIEF OF
STAFF
A124-1
ADMIN ASST
A117-1
RECEPTION
A116A-1
QUI COORD
A115-1
OFFICE
A119-1
OFFICE
A120-1
OFFICE
A122-1
ASSOCIATE
DIRECTOR
A112-1
COPY FILES
A114-1
OFFICE
A107A-1
TOILET
A112C-1
HOSPITAL
DIRECTOR
A111-1
RECEPTION
A109-1
RECEPTION
A108-1
OFFICE
A106-1
OFFICE
A105-1
OFFICE
A107-1
OFFICE
A104-1
RECEPTION
A102-1
OFFICE
A101-1
MENS
TOILET
A160-1
WOMENS
TOILET
A159-1
EXAM 7
D371-1
FDVA OFFICE
D162-1
FDVA OFFICE
D163-1
ELEC
D166-1
OFFICE
D370A-1
OFFICE
D361-1
EXAM 8
OFFICE
D326A-1
OFFICE
D326B-1
OFFICE
D326C-1
STAFF ONLY
D352-1
OFFICE
D353-1
OFFICE
D355A-1
EXAM 1
D350-1
EXAM 2
D347-1
EXAM 3
D346-1
EXAM 4
D355B-1
EXAM 5
D358-1
OFFICE
D357-1
OFFICE
D355C-1
OFFICE
D355-1
OFFICE
D356-1
WAITING
D336-1
CLOSET
A111A-1
CLOSET
A112A-1
ELEC
A116B-1
OFFICE
A121-1
WOMENS
WET
BATHROOM
B215-1
OCCUPATIONAL
THERAPY
OFFICE
OFFICE
OFFICE
A114C-1
CONFERENCE
ROOM
A128-1
ASSISTANT
CHIEF
A151-1
CHIEF
A152-1
OFFICE
A153-1
OFFICE
A155-1
CONFERENCE
ROOM
A154-1
STERILE
PREP.
A164B-1
OFFICE
D323A-1
OFFICE
D324B-1
OFFICE
D324C-1
MENS
TOILET
D320-1
WOMENS
TOILET
D319-1
LOUNGE
D321-1
MICROSCOPE
ROOM
D325-1
PATHOLOGY
D329-1
CLERICAL
AUTOPSY/
PATHOLOGY
D318-1
STORAGE
D315-1
OFFICE
D316-1
OFFICE
D333-1
FLOW
CYTOMETRY
D314-1
MICROBIOLOGY
LAB
D334-1
WOMENS
TOILET
D311-1
MENS
TOILET
D310-1
BACTERIOLOGY
D312-1
RESTROOM
D351-1
HISTOLOGY
D341A-1
CYTOLOGY
D341B-1
SURGICAL
PATHOLOGY
LAB.
D340-1
CYTOLOGY
D339-1
HISTOLOGY
D341C-1
WORK ROOM
EXAM 6
D344-1
TOILET
D307B-1
EXAM
C317-1
TOILET
C318-1
LAB
D375-1
OFFICE
D376-1
CONSULT
D161B-1
OFFICE
D374-1
STORAGE
D373-1
PARALYZED
VET. OF
AMERICA
D161A-1
FDVA OFFICE
D161-1
WORK/LOUNGE
D372-1
X-RAY
D307-1
BIOMED
WORKSHOP
D366F-1
OFFICE
D343-1
OFFICE
OFFICE
D331-1
OFFICE
D332-1
OFFICE
RAD.
OFFICES
FILE ROOM
D337A-1
ISOLATION
C286B-1
SOILED
UTILITY
C286A-1
OFFICE
EXAM
C340-1
OFFICE
D363B-1
EXAM 2
D170-1
CLEAN
UTILITY
D167-1
EXAM
C344-1
OFFICE
C345-1
EXAM
C346-1
EXAM
C347-1
EXAM
C348-1
EXAM
C349-1
STORAGE
C263-1
DATA
C263A-1
BED 6
ISOLATION
C244A-1
BED 7
ISOLATION
C244B-1
BED 8
ISOLATION
C244C-1
LINEN
C244D-1
SICU
C244-1
OFFICE
C244F-1
CATH LAB
C246A-1
DARK ROOM
WORK ROOM
C244H-1
LOUNGE
C244G-1
BIO. HAZARD
STORAGE
C242-1
TOILET
C243A-1
KITCHEN
C243-1
COMPUTER
ROOM
C246C-1
CONTROL
ROOM
C246B-1
SPD
STORAGE
B189-1
STORAGE
B188A-1
SOILED
UTILITY
BED 5
ISOLATION
B193-1
BED 6
ISOLATION
B192-1
STORAGE
B195-1
OFFICE
B194-1
LOCKERS
B184-1
LOUNGE
B185B-1
CHARTING
B188C-1
ON-CALL
B187-1
LINEN
B186-1
TOILET
B185A-1
LOCKERS
B185C-1
TOILET
B187A-1
CCU & SICU
STORAGE.
B383-1
OFFICE
B182C-1
OFFICE
B198-1
OFFICE
B201-1
SURGICAL
ADMIN
B182A-1
OFFICE
B182B-1
OFFICE
B181D-1
OFFICE
B235B-1
CHIEF
SECURITY
B141A-1
RECEPTION
B141-1
OFFICE
B138B-1
OFFICE
B139A-1
OFFICE
B137C-1 RECEPTION
B137-1
CHIEF OF
SURGERY
B137A-1
RECEPTION
B138-1
OFFICE
A132A-1
DATA
A132-1
OFFICE
A134-1
INPATIENT
PHARMACY
A164-1
RESEARCH
A164E-1
OFFICE
A164D-1
OFFICE
LOUNGE
A103A-1 BREAK
ROOM
A114B-1
OFFICE
A114A-1
VEST
A116-1
OFFICE
A118-1
LOBBY
A100-1
OFFICE
C272-1
OFFICE
B196-1
PHARMACY
ADMINISTRATION
A150-1
STORAGE
B137B-1
WAITING
D420-1
CT SCAN
CONTROL
D421-1
CT SCAN 3
D422-1
OFFICE
A103-1
OFFICE/STORAGE
B226A-1
GENERAL
CLINIC
WAITING
AREA
FEC
TOILET
D370-1
SCRUB
C438-1
TOILET
D301B-1
CONTROL
D301A-1
CONTROL
NURSE
STATION
C286C-1
FEC
RECEPTION
C244E-1
FEC
DATA
C447-1
DATA
C448-1
DATA
C449-1DATA
C450-1
B451-1
ANTE ROOM
CTICU
B188-1
OFFICE
B225A-1
OFFICE
B217A-1
EXAM
B227-1
FEC
EXAM
B136A-1
OFFICE
B137D-1
FEC
DATA
DIRECTORS'
OFFICES
A110-1
FEC
BREAK
ROOM
A164F-1
X-RAY
DIAGNOSTIC
II
D338-1
LOUNGE
C265B-1
ELEVATOR
S-1
ELEVATOR
S-2
ELEVATOR
P-4
ELEVATOR
P-3
ELEVATOR
P-6
ELEVATOR
P-5
STAIR
3-1
STAIR
2-1
STAIR
1-1
STAIR
4-1
OFFICE
A114D-1
STORAGE
A164N-1
STORAGE
A164O-3
ANTE ROOM
STORAGE
STORAGE
A405-1
OFFICE
A140B-1
FEC
STORAGE
FEC
NURSE
STATION
B188B-1
STORAGE
C244J-1
STORAGE
C259C-1
PACU
C286-1
FEC
OFFICE
D364-1
OFFICE
D337B-1
FEC
CONTROL
D308A-1
CONTROL
D307A-1
OFFICE
D341E-1
RECEPTION
OFFICE
D324-1
OFFICE
D323-1
TCA1B
CORRIDOR
C1-26-1
FEC
POOL
VENDING
C1-26A-1
ELEVATOR A
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
1 1
4 4
2 TYP
TYP
1 1
MENS
RESTROOM
B212-1
WOMENS
RESTROOM
B211-1
6 5
D A
C B
EF
G
KEY PLAN
TRUE
NORTH
PLAN
NORTH
DEMO PLAN GENERAL NOTES
A. CONTRACTOR SHALL GUT AND REMOVE ALL EXISTING CONSTRUCTION DOWN TO EXISTING STUDS/ STRUCTURE REQUIRED TO INSTALL NEW WORK AND SHALL DISPOSE OF ALL DEMOLISHED MATERIALS IN
AN APPROVED, OFFSITE LANDFILL EXCEPT WHERE OTHERWISE REQUIRED FOR SALVAGE OR
RECYCLING.
B. CONTRACTOR SHALL DEMOLISH ALL EXISTING MILLWORK, TOILET ACCESSORIES, GRAB BARS, COUNTERTOPS, AND TOILET PARTITIONS IN AREA OF WORK.
C. REFER TO AND COORDINATE WITH OTHER DICSIPINES DRAWINGS AND DOCUMENTS FOR ADDITIONAL
INFORMATION AND INSTRUCTIONS.
D. REMOVE AND STORE EXISTING SIGNAGE FOR REINSTALLATION.
E. DEMOLISH EXISTING FLOORING & BASE INCLUDING FLOORING UNDERLAYMENT IN AREA OF WORK AS
NEEDED TO INSTALL NEW WORK.
EXISTING DOOR, HARDWARE AND FRAME ASSEMBLY TO REMAIN. PREPARE SURFACE FOR NEW FINISH.
DEMO FLOOR PLAN KEY NOTES #
2 DEMOLISH EXISTING LOCKERS AND BENCHES.
3 DEMOLISH EXISTING WALL & FLOOR EXPANSION JOINT COVER IN AREA OF WORK AS INDICATED.
4 DEMOLISH EXISTING DOOR, FRAME ASSEMBLY AND HARDWARE AS INDICATED.
5 REMOVE EXISTING EQUIPMENT, RELOCATE AND STORE AT A APPROVED LOCATION FOR
REINSTALLATION.
DEMO PLAN LEGEND
EXISTING CONSTRUCTION
TO REMAIN
EXISTING CONSTRUCTION TO BE
DEMOLISHED
2-HOUR FIRE BARRIER
1-HOUR FIRE BARRIER
AREA OF WORK
VA FORM 08-6231
1 2 3 4 5 6 7 8 9
Date:
Drawing Title:
Approved Project Director
Project Title:
1 2 3 4 5 6 7 8 9
FINAL CONTRACT
SUBMITTAL590 MEANS ST NW
Phase Project Number
Building Number
Drawing NumberLocation
Issue Date CheckedFULLY SPRINKLERED
STAMP
STE. 200
ATLANTA, GA 30318
ARCHITECT/ENGINEER OF RECORDCONSULTANT
A
B
C
D
E
F
U.S. Department of Veterans Affairs
Office of Construction and
Facilities Management
Drawn
1 & 12
SJ/EO/SMTS
573-20-604
OVERALL FIRST FLOOR DEMO
PLAN - AREA A, B, C & D
RENOVATE COMMON AREA
RESTROOMS
GAINESVILLE, FLORIDA
AD104
03-21-2024
1/16" = 1'-0"AD104
1 FIRST FLOOR DEMO PLAN - AERA A,B,C,D
SCALE:
0' 8' 16' 32' 48'
1/16" = 1' - 0" smittal Snapshot smittal Image smittal
B
C
D
E
F
G
H
J
K
L
25 24 23 22 21.2 20 19 18 17 16
D1
E1
K5
M
20.221.4
209 SF
OFFICE
E126E-1
37 SF
MECH
E126D-1
117 SF
LOUNGE
E126C-1
127 SF
OFFICE
E126A-1
960 SF
CORRIDOR
CE-8-1
169 SF
OFFICE
E182-1
144 SF
CHIEF
OFFICE
E181-1
99 SF
RECEPTION
E193A-1
5418 SF
CHEMISTRY
AND
MICROBIOLOGY
E126-1
20 SF
TOILET
E194B-1
25 SF
DRESS
E149A-1
234 SF
X-RAY
GENERAL
E149-1
599 SF
CORRIDOR
CE-9-1
34 SF
TOILET
E183-1
103 SF
OFFICE
E184-1
99 SF
OFFICE
E185-1
104 SF
OFFICE
E187-1
134 SF
LOUNGE
E188-1
91 SF
TOILET
E189-1
96 SF
OFFICE
E190-1
279 SF
READING
ROOM
E191-1 183 SF
MECH
E197-1
429 SF
OPERATING
ROOM E
E175-1
115 SF
SUB STERILE
E173-1
436 SF
OPERATING
ROOM F
E171-1
39 SF
HAC
E170A-1
57 SF
STORAGE
E170-1
212 SF
EQUIPMENT
ROOM
E179B-1
392 SF
TOMOGRAPHIC
TREATMENT
ROOM
E195B-1
115 SF
SCRUB
E171A-1
533 SF
CORRIDOR
CE-15-1
117 SF
SCRUB
E176A-1
147 SF
ELEC
E169-1
623 SF
OPERATING
ROOM H
E176-1
101 SF
SUB STERILE
E174-1
545 SF
OPERATING
ROOM G
E172-1
85 SF
STORAGE
E177-1
101 SF
GAS
STORAGE
E177A-1
383 SF
EMERGENCY
ENTERANCE
E-C1-1
1659 SF
WAITING
E100-1
211 SF
RECEPTION
A101A-1
100 SF
EXAM
E104-1
92 SF
EXAM
E105-1
69 SF
CORRIDOR
E-C1-6-1
61 SF
TOILET
E106-1
181 SF
CORRIDOR
E-C1-5-1
150 SF
OFFICE
E118-1 228 SF
ELEVATOR B
E-C1-7-1
119 SF
OFFICE
E103-1
154 SF
LOCKER
ROOM
E102-1
45 SF
TOILET
E102A-1
37 SF
HAC
E114-1
168 SF
CORRIDOR
E-C1-4-1
112 SF
SECURITY
E101-1
91 SF
MEDIC
E116-1
301 SF
LIFE
SUPPORT
E113-1
277 SF
ELEVATOR B
E-C1-14-1
60 SF
RESTROOM
E108-1
369 SF
NURSE
STATION
E115-1
123 SF
CLEAN
SUPPLY
E112-1
93 SF
SOILED
UTILITY
E111-1
74 SF
TOILET
E117B-1
100 SF
ON-CALL
E117-1
291 SF
MINOR
OPERATING
ROOM
E110-1
1047 SF
CORRIDOR
E-C1-11-1
107 SF
CORRIDOR
E-C1-15-1 67 SF
INTERVIEW
ROOM
E128-1
576 SF
CORRIDOR
E-CQ-16-1
182 SF
SOILED
HOLDING
E135-1
86 SF
ELEC
E155-1
128 SF
DATA
E156-1 131 SF
PERIOPERATIVE
EDUCATION
E154-1 162 SF
CORRIDOR
E-C1-12
37 SF
TOILET
E153-1
130 SF
OFFICE
E152-1
52 SF
VEST
E151C-1
477 SF
MENS
LOCKER
ROOM
E151-1
321 SF
WOMENS
LOCKER
ROOM
E150-1
183 SF
DRESSING
ROOM
E150D-1
87 SF
VEST
E150A-1
173 SF
WOMENS
TOILET
E150B
59 SF
DICTATION
268 SF
MENS
TOILET
E151B-1
50 SF
VEST
E151A-1
168 SF
STORAGE
E142C-1
41 SF
TOILET
E140B-1
161 SF
NURSE
STATION
E140-1
52 SF
HAC
E141-1
69 SF
STORAGE
E141A-1
538 SF
OPERATING
ROOM K
E142-1
351 SF
STERILE
STORAGE
E148-1
86 SF
OFFICE
E146-1
478 SF
OPERATING
ROOM J
E144-1
760 SF
CLEAN CORR
1-C1-21
249 SF
SUB-STERILE
E145-1
483 SF
OPERATING
ROOM I
E143-1
212 SF
STORAGE
E147-1
90 SF
CORRIDOR
E-C1-22-1
153 SF
CORRIDOR
E-C1-23-1
144 SF
CORRIDOR
E-C1-24-1
99 SF
BED 4
E109-1
1434 SF
CORRIDOR
E-C1-8-1
210 SF
STAIR
1-5
206 SF
STAIR
1-6
80 SF
ELEVATOR
73 SF
ELEVATOR
73 SF
ELEVATOR
77 SF
ELEVATOR
106 SF
SECLUSION
E109A-1
91 SF
BED 5
12 SF
ELEC
E109B-1
79 SF
PATIENT
VALUABLES
E107-1
88 SF
STORAGE
E142A-1
159 SF
CONTROL
E140A-1
30 SF
NUTRITION
1705 SF
RECOVERY
462 SF
WORK ROOM
STORAGE
E178A-1
90 SF
CONTROL
E195A-1
115 SF
CONTROL
E179A-1
397 SF
SCAN ROOM
E179-1
279 SF
STORAGE
E136-1
84 SF
RECEPTION
E193B-1
119 SF
OFFICE
E126B-1
256 SF
STORAGE
16 SF
DATA
E170B-1
16 SF
46 SF
LOCKERS
E128A-1
136 SF
STORAGE
92 SF
BED 3
96 SF
BED 2
96 SF
BED 1
69 SF
REFRIGERATOR
56 SF
REFRIGERATOR
51 SF
STORAGE
D A
C B
EF
G
TRUE
NORTH
PLAN
NORTH
DEMO GENERAL NOTES
A. CONTRACTOR SHALL GUT AND REMOVE ALL EXISTING CONSTRUCTION DOWN TO EXISTING STUDS/ STRUCTURE REQUIRED TO INSTALL NEW WORK AND SHALL DISPOSE OF ALL DEMOLISHED MATERIALS IN
AN APPROVED, OFFSITE LANDFILL EXCEPT WHERE OTHERWISE REQUIRED FOR SALVAGE OR
RECYCLING.
B. CONTRACTOR SHALL DEMOLISH ALL EXISTING MILLWORK, TOILET ACCESSORIES, GRAB BARS, COUNTERTOPS, AND TOILET PARTITIONS IN AREA OF WORK.
C. REFER TO AND COORDINATE WITH OTHER DICSIPINES DRAWINGS AND DOCUMENTS FOR ADDITIONAL
INFORMATION AND INSTRUCTIONS.
D. REMOVE AND STORE EXISTING SIGNAGE FOR REINSTALLATION.
E. DEMOLISH EXISTING FLOORING & BASE INCLUDING FLOORING UNDERLAYMENT IN AREA OF WORK AS
NEEDED TO INSTALL NEW WORK.
DEMO FLOOR PLAN KEY NOTES #
1 EXISTING DOOR, HARDWARE AND FRAME ASSEMBLY TO REMAIN. PREPARE SURFACE FOR NEW FINISH.
0' 4' 8' 16' 24'
SCALE: 3/32" = 1'-0"
32'
DEMO PLAN LEGEND
EXISTING CONSTRUCTION
TO REMAIN
EXISTING CONSTRUCTION TO BE
DEMOLISHED
2-HOUR FIRE BARRIER
1-HOUR FIRE BARRIER
AREA OF WORK
VA FORM 08-6231
1 2 3 4 5 6 7 8 9
Date:
Drawing Title:
Approved Project Director
Project Title:
1 2 3 4 5 6 7 8 9
FINAL CONTRACT
SUMBITTAL590 MEANS ST NW
Phase Project Number
Building Number
Drawing NumberLocation
Issue Date CheckedFULLY SPRINKLERED
STAMP
STE. 200
ATLANTA, GA 30318
ARCHITECT/ENGINEER OF RECORDCONSULTANT
A
B
C
D
E
F
U.S. Department of Veterans Affairs
Office of Construction and
Facilities Management
Drawn
1 & 12
SJ/EO/SMTS
573-20-604
OVERALL FIRST FLOOR DEMO
PLAN - AREA E
RENOVATE COMMON AREA
RESTROOMS
GAINESVILLE, FLORIDA
AD105
03-21-2024
3/32" = 1'-0"AD105
1 OVERALL FIRST FLOOR DEMO PLAN - AREA E
KEY PLAN E
smittal Snapshot smittal Image smittal
2526272829303132
B.2
C.2
D.2
E.2
333435
E.7
F.5
G.7
J
K.3
M
M.6
N
E.8 j k l
SOILED
UTILITY
F107-1
VEST
F103I-1
UNOCCUPIED
F108-1
UNOCCUPIED
F109-1
UNOCCUPIED
F110-1
UNOCCUPIED
F111-1
ASSIST.
CHIEF
PATIENT
PROCESSING
F102-1
ADMISSIONS
F101-1
CORRIDOR
F-C1-5
SOCIAL
WORK
F104-1
SOCIAL
WORK
F105-1
WAITING
F-C1-3
LOBBY
F-C1-2
VEST
F-C1-1
RELEASE OF
INFORMATION
F138-1
TRAVEL
F139-1
STAIR
RECEPTION
F-C1-7
CORRIDOR
F-C1-8
TOILET
F120-1
CORRIDOR
F-C1-10
ASSIST.
NURSE
MANAGER
EDUCATOR
F114-1
EXAM
F115-1
CHIEF
PRIMARY
CARE
F116-1
NURSE
MANAGER
F117-1
SECRETARY
PRIMARY
CARE
F118-1
CHIEF
MEDICAL
OFFICER
F119-1
ADMIN.
OFFICER
PRIMARY
CARE
F121-1
ACOS CHIEF
NURSE PCO
F123-1
CHIEF
F123A-1
ADMIN.
OFFICER
PRIMARY
CARE
F125-1
ASSIST.
CHIEF
NURSE
F127-1
SUPERVISORY
PROG
SUPPORT
ASSISTANT
F129-1
ELEC
F137-1
STORAGE/FUT.
ELEV.
F136-1
MENS
TOILET
F135-1
WOMENS
TOILET
F134-1
DATA
F122-1
FACILITY
TELEHEALTH
COOD/
MANAGEMENT
& PROG
ANALYST
F124-1
HEALTH
PROMOTION
DISEASE
PREVENTION
F126-1
VETERANS
HEALTH
EDUCATION
COOR
F128-1
PCMM
COORDINATOR
F130-1
ELEVATOR
LOBBY
F-C1-14
CORRIDOR
F-C1-13
PRIMARY
CARE
CONFERENCE
F131-1
SUPERVISORY
PROG
SPECIALIST
F132-1
LEAD
MEDICAL
SUPPORT
ASSIST.
F133-1
CORRIDOR
F-C1-11
CORRIDOR
F-C1-12
WAITING
C-G1-17-1
NUTR. CLINIC
G167-1
OFFICE
G168K-1
DIET. O.
G169-1
DIET. O.
G170-1
PHARMACIST
CONSULTATION
G171-1
OFFICE
G168L-1
CORRIDOR
GC116-1
PHARMACIST
G100-1
EXAM
G101-1
EXAM
G102-1
EXAM
G103-1
EXAM
G104-1
EXAM
G105-1
EXAM
G106-1
EXAM
G107-1
EXAM
G108-1
EXAM
G109-1
EXAM
G110-1
PROCEDURE
G111-1
CLEAN
SUPPLY
G112-1
CORRIDOR
GC113-1
MENS
TOILET
G113-1
WOMENS
TOILET
G114-1
VENDING
F-C1-15
WAITING
GC12-1
WORK ROOM
GC15A-1
RECEPTION
GC15-1
EXAM
G116-1
EXAM
G117-1
EXAM
G118-1
EXAM
G119-1
EXAM
G120-1
EXAM
G121-1
EXAM
G122-1
EXAM
G123-1
EXAM
G124-1
EXAM
G125-1
CONF.
CENTER
G126-1
STAFF
LOUNGE
G127-1
PHARMACIST
GC15B-1
EXAM
GC129-1
EXAM
G130-1
EXAM
G131-1
EXAM
G132-1
EXAM
G133-1
EXAM
G134-1
EXAM
G135-1
EXAM
G136-1
CONSULT
(TB)
G137-1
SOILED
UTILITY
G138-1
HAC
G139-1
MENS
TOILET
G140-1
WOMENS
TOILET
G141-1
TOILET
G142-1
WORK ROOM
G117A-1
EXAM
G144-1
EXAM
G145-1
EXAM
G146-1
EXAM
G147-1
EXAM
G148-1
EXAM
G149-1
EXAM
G150-1
EXAM
G151-1
EXAM
G152-1
PC3
NURSING
G153-1
EXAM
G154-1
WORK ROOM
G117B-1
EXAM
G156-1
WORK ROOM
G119A-1
EXAM
G158-1
WORK ROOM
G119B-1
EXAM
G160-1
EXAM
G111A-1
CONSULT
(TB)
G162-1
ELEC
G163-1
RADIOLOGY
SUITE
G164-1
PROC.(CAST)
G165-1
MED. &
TREAT.
G166-1
OFFICE
G111B-1
EXAM
G155-1
CONSULT
G157-1
TOILET
G159-1
DATA
G161-1
TOILET
G164A-1
CORRIDOR
CORRIDOR
GC114-1
CORRIDOR
GC110-1
CORRIDOR
GC118-1
CORRIDOR
CORRIDOR
CONFERENCE
ROOM
G168J-1
WOMENS
TOILET
G168H-1
MENS
TOILET
G168G-1
HAC
G168F-1
TOILET
G127A-1
ONCOLOGY
G168E-1
OFFICE
GC115-1
OFFICE
G168D-1
CHIEF OF
OPERATIONS
G168C-1
OUTPATIENT
PHARMACY
SUPERVISOR
G168B-1
ORDER
ENTRY
G168A-1
OUTPATIENT
PHARMACY
G168-1
RECEPTION
GC117-1
RECEPTION
GC119-1
RECEPTION
GC111-1
WAITING
GC112-1
STAIR
WAITING
GC11-1
ADMISSIONS
OFFICE
F112-1
CLEAN
UTILITY
F103G-1
ALCOVE
MED ROOM
F103F-1
EXAM 5
F103E-1
EXAM 4
F103D-1EXAM 3
F103C-1
EXAM 2
F103B-1
EXAM 1
F103A-1
EXAM
F103-1
TOILET
F106-1
E.R. / CHEST
PAIN UNIT
F103H-1
COPY
F131A-1
CONTROL
ROOM
G164B-1
EXAM
EXAM
OFFICE
F143-1
OFFICE
F141-1
8' - 7 3/16"
1 1
D A
C B
EF
G
TRUE
NORTH
PLAN
NORTH
0' 4' 8' 16' 24'
SCALE: 3/32" = 1'-0"
32'
DEMO PLAN LEGEND
EXISTING CONSTRUCTION
TO REMAIN
EXISTING CONSTRUCTION TO BE
DEMOLISHED
2-HOUR FIRE BARRIER
1-HOUR FIRE BARRIER
AREA OF WORK
DEMO GENERAL NOTES
A. CONTRACTOR SHALL GUT AND REMOVE ALL EXISTING CONSTRUCTION DOWN TO EXISTING STUDS/ STRUCTURE REQUIRED TO INSTALL NEW WORK AND SHALL DISPOSE OF ALL DEMOLISHED MATERIALS IN
AN APPROVED, OFFSITE LANDFILL EXCEPT WHERE OTHERWISE REQUIRED FOR SALVAGE OR
RECYCLING.
B. CONTRACTOR SHALL DEMOLISH ALL EXISTING MILLWORK, TOILET ACCESSORIES, GRAB BARS, COUNTERTOPS, AND TOILET PARTITIONS IN AREA OF WORK.
C. REFER TO AND COORDINATE WITH OTHER…
This is the start of the file's text. The full file is on GovTribe.