This document is the Salient Characteristics for a requirement to fabricate and deliver mobile guard shacks. The key details are:

The guard shack must meet specific requirements, including being constructed of bulletproof metal, having ballistic-rated windows and gun ports, internal and external lighting, air conditioning, a generator, and a lightweight trailer for mobility. The dimensions, weight, and other technical specifications are provided. The applicable directives are UFC 4-022-01, UFC 4-010-01, UFC 3-530-01, and UFC 4-023-07.

This salient characteristics document is related to Federal Contract Opportunity FA557024QB003 issued by the Department of the Air Force United States Air Forces in Europe - Air Forces Africa for the Fabrication and Delivery of Mobile Guard Sheds. Proposals are due by September 18, 2024 at 1500 GMT.

View the file

Other files for this federal contract opportunity

Show all 11

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Salient Characteristics Overview: 1 (one) secure Guard Shack affixed to a metal trailer. The Guard Shack and Trailer shall consist of the following equipment as described below:

A. Guard Shack Material: Bulletproof metal flat sheets welded onto the frame (Entire Structure), Including the protection of the external air conditioning unit. Material shall be UFC 4-022-01 Level 5 Compliant.

B. Guard Shack Dimensions: Must meet internal measurements of 1.5 m width by 1.5 m length by

2.25 m height.

C. Ballistic Rated Windows: One (1) window for each wall. Each window shall be no less than one meter in height from the floor of the unit and shall be centered on wall. Windows shall be UFC 4-

23-07 compliant.

D. Ballistic Rated Window Dimensions: Must meet (1) meter in height and 75 mm in width.

E. Ballistic Rated Sliding Window: The window above the Internal Shelf shall slide open.

F. Internal Shelf: Shall be centered and securely fixed to the wall across from the door. Shall be fixed no higher than 85 mm from the floor of the structure.

1. Shall be made of corrosion resistant metal. Support a minimum of 60 Kg.

2. Face up surface shall be textured for grip.

G. Internal floor: Shall be aluminum sheet anti slip.

H. Door: Must open outward with a vision panel and gun port. Door shall be UFC 4-023-07 and UFC 4-022-01 Level 5 Compliant.

I. Self Defense Gun Ports: Four (4) gun ports total: One (1) gun port under each window and one

(1) under the vision panel on the door. Gun ports must be UCF 4-022-01 para 5-7.5.1 compliant.

J. External Paint:

1. Primer coating

2. two (2) paint coatings

3. electrostatically applied.

4. Paint color must be Coyote Brown or equal.

5. Paint must be weather resistant.

K. Air Conditioning Split System: 1 (one) unit with the minimum specifications:

1. 9,000 btu, Inverter type with Noiseless operation 21dB(A) R-32, Cooling and Heating

2. Internal Unit Shall be wall mounted.

L. External Lighting: Shall be installed on the four corners of the structure. Provide Vehicle Traffic area lighting IAW UFC 3-530-01. Lights shall be able to be manually controlled from inside the structure.

M. Internal Lighting: Must comply with UFC 3-530-01 Design: Interior and Exterior Lighting and Controls, to include two (2) dimmable LED ceiling lights and one (1) Emergency light with a kinetic rechargeable battery.

N. External Electrical: All entrances of cables are ballistically protected. All cable housing must have IP65 Weatherproof Protection.

O. Internal Electrical: Two (2) sockets, Standard UK 3 pin 220v Type G. Both sockets shall be installed above the Metal Shelf. Shall comply with UFC 4-023-07.

P. Silent Generator: 7 Kw Generator, Petrol, maximum noise rating of 60 DB. Shall be connected to an external plug that will power the entire structure.

1. Generator shall be located on the hitch side of the trailer bed.

2. Shall be fixed to the bed of the trailer.

3. Fuel capacity: 6 hours at full output.

Q. Fire extinguisher: Shall comply with DAFMAN 91-203, paragraph 6.2.6.4.

1. Shall be a minimum of 10 Lbs.

2. Request DOD Safe Link for approved companies

3. Shall be ABC Dry Powder/chemical

R. Lightweight Trailer:

1. Must be registered with UK Department for Transport and Vehicle Standard Agency laws.

2. Shall not have a gross weight including sentry cabin of more than 3.5 tons.

3. Shall be able to carry mobile Guard Shack in the upright position with all equipment as listed above.

4. Shall have braking system.

5. Shall have a 2 Inch ball hitch for towing.

S. Floor Plan: for the guard shacks shall be electronically submitted upon delivery of all guard shacks.

Applicable Directives:

UFC 4-022-01 - Security Engineering: Entry Control Facilities / Access Control Points UFC 4-010-01 - DOD Minimum Antiterrorism Standards for Buildings UFC 3-530-01 - Interior and Exterior Lighting and Controls UFC 4-023-07 – Design to Resist Direct Fire Weapons Effects