This is a Statement of Work (SOW) for the repair of a tower elevator system located at the ASDE Remote Tower (FAA) facility in Houston, Texas at 18210 Aldine Westfield Road, Houston, TX 77032. The elevator is an Alimak Rack & Pinion model that has experienced operational issues requiring repair, specifically a sticking and overheating brake caused by normal wear, environmental exposure, and continued operational use. The project objective is to restore the elevator to safe, reliable, and fully operational condition in compliance with applicable codes and standards.
The contractor shall provide all labor, materials, tools, equipment, transportation, and supervision necessary to complete inspection and diagnostics of the existing system; repair or replacement of defective mechanical, electrical, and control components; adjustment, alignment, lubrication, and calibration of elevator components; and functional and load testing with safety verification. All contractor personnel require FAA-escorted access at the on-site work location. Deliverables include a report of findings and remediation, a certificate of occupancy and load rating, and completion of joint acceptance testing once the vendor notifies the FAA that work is complete. All deliverables shall be provided electronically. No response dates, award dates, or pricing information is specified in this SOW.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SERVICES
STATEMENT OF WORK
For IAH-R ASDR Tower Elevator Repair
1. Introduction and Overview
This SOW defines the scope, responsibilities, and requirements for the repair of the tower elevator system located at ASDE Remote Tower (FAA) – IAH, 18210 Aldine Westfield Rd, Houston, TX 77032. The purpose of this project is to restore the elevator to a safe, reliable, and fully operational condition in compliance with applicable codes and standards.
2. Background
The tower elevator at the subject site is an Alimak Rack & Pinion elevator and has experienced operational issues and requires repair to ensure safe, reliable access to tower infrastructure. One of the known issues is a sticking and overheating brake. Due to normal wear, environmental exposure, and continued operational use, certain elevator components have degraded and no longer perform as intended. Timely repair is necessary to restore full functionality, maintain compliance with applicable safety standards, and support ongoing site operations.
3. Scope of Work
The Contractor shall provide all labor, materials, tools, equipment, transportation, and supervision necessary to complete the following:
• Inspection, diagnostics, and assessment of the existing tower elevator system
• Repair or replacement of defective mechanical, electrical, and control components
• Adjustment, alignment, lubrication, and calibration of elevator components
• Functional testing, load testing, and safety verification
• Documentation and reporting of completed work
4. Location of Work
Work shall be performed at the ASDE Remote Tower (FAA) – IAH 18210 Aldine Westfield Rd, Houston, TX 77032, (29°58'56.84"N 95°21'49.23"W) including all associated tower elevator equipment, control systems, and related infrastructure. Contractor personnel will perform work on-site at the tower location.
5. References N/A
6. Other Considerations
• FAA escorted access required for all personnel
7. Progress / Compliance
• Provide report of findings and remediation
• Provide certificate of occupancy and load rating
• Joint Acceptance Testing will be completed once vendor informs FAA work is complete
8. Transmittal / Delivery / Accessibility
All deliverables shall be provided electronically only as applicable.