Attachment 01 - Concrete.pdf
PDF 903 KB Posted
- Attached to
- AAC-RFQ-24-014 Fuel Concrete Pad (Concrete)
- Solicitation number
- AAC-RFQ-24-014 Fuel Concrete Pad (Concrete)
- Issued by
- Dillingham Census Area, Alaska
About this file
This document is a set of civil engineering specifications for the demolition and rebuild of an existing launch pad, grading, paving, site fencing, drainage and deluge containment system for the Area 3 launch pad at the Alaska Aerospace Corporation's Pacific Spaceport Complex-Alaska. The project scope involves the demolition and rebuild of the existing launch pad, along with associated site work such as grading, paving, fencing, drainage, and a deluge containment system. The contractor is required to submit red-lined as-built drawings upon completion and comply with all applicable local, state, and federal regulations. Material and testing requirements are specified, including for concrete, earthwork, and utilities. The contractor is responsible for establishing survey control, maintaining site security, and managing traffic during construction.
The specifications detail requirements for concrete strengths, reinforcement, steel, and welding. Specific requirements are provided for silt fencing, chain link fencing, gates, and joint sealants. The contractor must utilize materials and methods that conform to relevant ASTM, AWWA, and ADOT/PF standards. Pricing, set-asides, and funding sources are not addressed in this document, which focuses on the technical specifications for the civil construction and site work.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 25-N1045C ITB.pdf | ||
| Attachment 01 - Concrete.pdf.crdownload | CRDOWNLOAD file | |
| BAAF BLDG. #47420 BOILER REPLACEMENT ITB.pdf | ||
| RFQ Fuel Concrete Slab - Concrete.docx | DOCX document | |
| RFQ 2524C097 Lime Village (2AK) Rural Airport Maintenance - Amendment Two.pdf | ||
| Fuel Concrete Slab (ANLY3) - CONCRETE.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
P:
\C
5.0
.00
AA
C
- A
RE
A 3 P
AD
C
R
EB
UI
LD
EN
G
SU
PP
OR
T\
SH
EE
TS
\C -0
.D
W G
5/1 7/2
4 1
1:3 8 A
M
C06885.030.00
CIVIL GENERAL
NOTES, LEGEND &
ABBREVIATIONS
C-001 54321 6
A
B
C
D
E
Architects Engineers, Inc.
These plans are protected by Federal Copyright protection. Unauthorized use may result in an infringement action.
www.brph.com Copyright © 2024
19020 33rd Ave W| Suite 500 Lynnwood | Washington | 98036 425-255-1095
Professional Licensing Division: AECC736
Offices in Melbourne, Orlando, Atlanta, Boca Raton, Lynnwood, and Charleston
DOCUMENT HISTORY
RECORD DOCUMENTS
REV DATE DESCRIPTION
AR
EA
P
AD
C
R
EB
U
IL
D N
A
RR
O W
C A
PE
KO
D
IA
K
IS
LA
N D
A
LA
SK
A
AL
AS
KA
A
ER
O
SP
AC
E
CO
RP
O
RA
TI
O N
DRAWING NO.
TITLE
PROJECT NUMBER
DRAWN BY
DESIGNED BY
ARCH/ENGR OF RECORD
DATE
05/09/2024
R
EC ORD
D
RA W IN
G
STATEMENT OF WORK
THE SCOPE OF THIS PROJECT IS COMPRISED OF THE DEMOLITION AND REBUILD OF AN EXISTING LAUNCH PAD, GRADING, PAVING, SITE FENCING, DRAINAGE AND DELUGE CONTAINMENT SYSTEM, RELATED TO THE AREA 3 LAUNCH PAD C AT ALASKA AEROSPACE CORPORATION'S PACIFIC
SPACEPORT COMPLEX-ALASKA.
CIVIL GENERAL NOTES
1. AFTER THE CONCLUSION OF CONSTRUCTION THE CONTRACTOR SHALL SUBMIT RED LINED DRAWINGS TO REFLECT THE AS-BUILT CONDITION
TO THE ALASKA AEROSPACE CORPORATION (AAC) CONTRACTING OFFICERS' TECHNICAL REPRESENTATIVE (COTR) TO BE USED TO DEVELOP
RECORD DOCUMENTS.
2. COMPLY WITH APPLICABLE LOCAL, STATE, AND FEDERAL REGULATIONS.
3. COMPLY WITH PERMIT CONDITIONS AND POST A COPY OF PROJECT PERMITS ONSITE ON A WEATHERPROOF DISPLAY BOARD.
4. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATIONS AND CRITICAL ELEVATIONS OF UTILITIES AND COORDINATE WITH THE APPROPRIATE AUTHORITIES AND UTILITY OWNERS PRIOR TO CONSTRUCTION. UTILITY CONFLICTS OR DISCREPANCIES ON THE DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO CONSTRUCTION.
5. NOTIFY THE AAC COTR FOR EXISTING UTILITY COORDINATION/VERIFICATION IN THE AREA AT LEAST 48 HOURS PRIOR TO CONSTRUCTION.
6. THE CONTRACTOR IS RESPONSIBLE FOR ESTABLISHING HORIZONTAL AND VERTICAL CONTROL FOR SITE CONSTRUCTION. THE CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OF SURVEY MONUMENTATION. DISTURBED SURVEY MONUMENTATION SHALL BE REPLACED BY A
SURVEYOR LICENSED IN THE STATE OF ALASKA.
7. DURING PHASES OF CONSTRUCTION, IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE SAFETY MARKINGS, BARRICADES, AND
TEMPORARY FENCING TO MAINTAIN JOBSITE SAFETY.
8. CONTRACTOR SHALL CONTRACT A CERTIFIED CONSTRUCTION MATERIALS TESTING LABORATORY TO PROVIDE MATERIALS AND DENSITY TESTING IN ACCORDANCE WITH ADOT STANDARDS. TESTING REPORTS SHALL BE PROVIDED TO THE ENGINEER OF RECORD PRIOR TO
CONSTRUCTION.
9. AREAS OUTSIDE THE LIMITS OF CONSTRUCTION THAT ARE DISTURBED BY THE CONTRACTOR SHALL BE RESTORED TO THEIR ORIGINAL
CONDITION AT NO COST TO THE OWNER.
10. TRAFFIC CONTROL DEVICES SHALL MEET THE REQUIREMENTS OF THE ALASKA DOT & PF. (DEPARTMENT OF TRANSPORTATION AND PUBLIC
FACILITIES)
11. EXISTING OFFSITE DRAINAGE PATTERNS SHALL BE MAINTAINED DURING CONSTRUCTION.
12. COORDINATE WITH THE OWNER'S REPRESENTATIVE TO MINIMIZE THE EXTENT OF CLEARED AND DISTURBED AREAS IN CONFORMANCE WITH
THE CONSTRUCTION PLANS.
13. DRAINAGE PIPES WITHIN THE PROJECT BOUNDARY SHALL BE CLEANED OF SAND, SILT, DEBRIS, ETC. DURING AND AT THE END OF
CONSTRUCTION TO MAINTAIN POSITIVE DRAINAGE.
14. EXISTING SITE SECURITY MUST NOT BE COMPROMISED. THE CONTRACTOR SHALL COORDINATE REMOVAL OF EXISTING FENCING AND
INSTALLATION OF FENCING TO MAINTAIN SECURITY.
15. THE CONTRACTOR IS RESPONSIBLE FOR AROUND-THE-CLOCK MAINTENANCE OF TRAFFIC BOTH ONSITE AND ON ADJOINING ROADWAYS DURING CONSTRUCTION. MAINTENANCE OF TRAFFIC AND ASSOCIATED NOTIFICATIONS SHALL COMPLY WITH ALASKA DOT & PF
REQUIREMENTS.
SITE CLEARING
1. REMOVE TREES, SHRUBS, GRASS AND OTHER VEGETATION, IMPROVEMENTS, OR OBSTRUCTIONS, WITHIN AREA OF WORK, TO PERMIT
INSTALLATION OF CONSTRUCTION. REMOVE SIMILAR ITEMS ELSEWHERE ON SITE OR PREMISES AS SPECIFICALLY INDICATED.
2. TOPSOIL IS DEFINED AS FRIABLE CLAY LOAM SURFACE SOIL, BROWN FIBROUS PEAT AS DEFINED IN THE GEOTECHNICAL ENGINEERING
REPORT BY R & M CONSULTANTS, INC., DATED JUNE 15, 2009.
3. STRIP TOPSOIL TO DEPTHS ENCOUNTERED IN A MANNER TO PREVENT INTERMINGLING WITH UNDERLYING SUBSOIL OR OTHER
OBJECTIONABLE MATERIAL
4. CONTRACTOR SHALL BE RESPONSIBLE TO ADHERE TO THE PROVISIONS FOR PROTECTION AND RESTORATION OF PROPERTY AND LANDSCAPE AS CONTAINED IN SECTION 107, PARAGRAPH 107.1.11 OF THE ALASKA DOT AND PUBLIC FACILITIES STANDARDS FOR HIGHWAY
CONSTRUCTION, 2017.
EARTHWORK
1. THE PROJECT GEOTECHNICAL REPORT WAS PERFORMED BY R & M CONSULTANTS, INC., DATED JUNE 15, 2009. THE BORING LOGS SHOW
SUBSURFACE CONDITIONS AT THE DATES AND LOCATIONS INDICATED, AND IT IS NOT WARRANTED THAT THEY ARE REPRESENTATIVE OF SUBSURFACE CONDITIONS AT OTHER LOCATIONS AND TIMES. THE CONTRACTOR SHALL COMPLY WITH THE RECOMMENDATIONS OF THE
GEOTECHNICAL REPORT.
2. COMPLY WITH APPLICABLE REQUIREMENTS OF NFPA 495 - EXPLOSIVE MATERIALS CODE.
3. SUBMIT MATERIAL TEST REPORTS, MATERIAL CERTIFICATES, AND COMPACTION TEST REPORTS, SIGNED AND SEALED BY AN ALASKA LICENSED PROFESSIONAL ENGINEER, TO THE ENGINEER OF RECORD & OWNER'S REPRESENTATIVE. NOT PERFORMED.
4. MATERIALS:
SAND:
DEFINED AS "BEACH SAND" ORIGINATING FROM THE BOAT BAY MATERIAL SITE.
STRUCTURAL FILL:
AGGREGATE BASE COURSE CONFORMING TO SECTION 703-2.03 OF THE ALASKA DEPARTMENT OF TRANSPORTATION AND PUBLIC FACILITIES STANDARD SPECIFICATIONS FOR HIGHWAY CONSTRUCTION, LATEST EDITION FOR D-1 BASE COURSE OR 8" MINUS PIT RUN. BOTH D-1 BASE COURSE AND 8" MINUS PIT RUN SHALL HAVE A MAXIMUM 6% BY WEIGHT PASSING THE NO. 200 SIEVE AND A
MAXIMUM 65% BY WEIGHT PASSING THE NO. 4 SIEVE.
5. THE TERM "BEDROCK" AS USED IN THESE DRAWINGS SHALL MEAN THE MODERATELY WEATHERED ROCK OF THE NARROW CAPE FORMATION
AS DEFINED IN TABLE 6 OF THE REFERENCED GEOTECHNICAL REPORT.
6. EXCAVATIONS BELOW SLABS-ON-GRADE AND SPREAD FOOTINGS SHALL BE MADE TO BEDROCK.
7. STRUCTURAL FILL TO BE USED BELOW SLABS AND LAUNCH PADS SHALL CONFORM TO THE DEFINITIONS AND REQUIREMENTS IN THE
ABOVE-REFERENCED GEOTECHNICAL REPORT.
8. STRUCTURAL FILL SHALL BE COMPACTED TO 95 PERCENT MAXIMUM DENSITY PER ASTM D 1557 (MODIFIED PROCTOR TEST) IN 9 INCH
MAXIMUM LIFTS.
9. SOIL MATERIAL CLASSIFICATION GROUPS GC, SC, ML, MH, CL, CH, OL, OH AND PT SHALL NOT BE USED UNDER STRUCTURES.
10. DEWATER SITE AS NECESSARY TO PREVENT SURFACE, SUBSURFACE OR GROUND WATER FROM ENTERING EXCAVATIONS.
11. COMPLY WITH LOCAL CODES, ORDINANCES, AND REQUIREMENTS OF AUTHORITIES HAVING JURISDICTION TO MAINTAIN STABLE
EXCAVATIONS.
12. PROVIDE APPROVED BORROW SOIL MATERIALS FROM OFF-SITE WHEN SUFFICIENT APPROVED SOIL MATERIALS ARE NOT AVAILABLE FROM
EXCAVATIONS.
13. SILT FENCE: GEOTEXTILES FOR SEDIMENT CONTROL SHALL BE IN ACCORDANCE WITH SECTION 633 OF THE ADOT/PF STANDARD
SPECIFICATIONS FOR HIGHWAY CONSTRUCTION, LATEST EDITION.
14. PROTECT SUBGRADES AND FOUNDATION SOILS AGAINST FREEZING TEMPERATURES OR FROST. PROVIDE PROTECTIVE INSULATING
MATERIALS.
15. PROVIDE EROSION CONTROL MEASURES TO PREVENT EROSION OR DISPLACEMENT OF SOILS AND DISCHARGE OF SOIL-BEARING WATER
RUNOFF OR AIRBORNE DUST TO ADJACENT PROPERTIES AND WALKWAYS.
16. PREVENT SURFACE WATER AND SUBSURFACE OR GROUNDWATER FROM ENTERING EXCAVATIONS, FROM PONDING ON PREPARED
SUBGRADES, AND FROM FLOODING THE PROJECT SITE AND SURROUNDING AREA.
17. PROTECT SUBGRADES, EXPOSED BEDROCK, AND FOUNDATION SOILS FROM SOFTENING AND DAMAGE BY CONSTRUCTION ACTIVITIES, CONSTRUCTION EQUIPMENT, AND RAIN OR WATER ACCUMULATION. NECESSARY REMEDIAL WORK SHALL BE PERFORMED AT NO ADDITIONAL
COST TO THE OWNER.
18. EXCAVATIONS FOR FOOTINGS AND FOUNDATIONS: DO NOT DISTURB BOTTOM OF EXCAVATION. EXCAVATE BY HAND TO FINAL GRADE AND COMPACT TO 95 PERCENT MAXIMUM DENSITY PER ASTM D 1557 BEFORE PLACING CONCRETE REINFORCEMENT. TRIM BOTTOMS TO REQUIRED
LINES AND GRADES TO LEAVE SOLID BASE TO RECEIVE OTHER WORK.
19. EXCAVATION FOR UNDERGROUND TANKS, BASINS, AND MECHANICAL OR ELECTRICAL APPURTENANCES: EXCAVATE TO ELEVATIONS AND DIMENSIONS INDICATED WITHIN A TOLERANCE OF PLUS OR MINUS 0.10 FOOT. DO NOT DISTURB BOTTOM OF EXCAVATIONS INTENDED FOR BEARING SURFACE. COMPACT UNDERLYING SOIL TO 95 PERCENT MAXIMUM DENSITY PER ASTM D 1557 PRIOR TO STRUCTURE/EQUIPMENT
INSTALLATION.
20. EXCAVATE UTILITY TRENCHES TO INDICATED SLOPES, LINES, DEPTHS AND INVERT ELEVATIONS SHOWN ON THE PROJECT PLANS. EXCAVATE
TRENCHES TO ALLOW INSTALLATION OF TOP OF PIPE BELOW FROST LINE.
21. TRENCH BOTTOMS: EXCAVATE AND SHAPE TRENCH BOTTOMS TO PROVIDE UNIFORM BEARING AND SUPPORT OF PIPES AND CONDUIT.
PROVIDE A MINIMUM 6" OF BEDDING SURROUNDING PIPING AND CONDUIT. SHAPE SUBGRADE TO PROVIDE CONTINUOUS SUPPORT FOR BELLS, JOINTS, AND BARRELS OR PIPES FOR JOINTS, FITTINGS AND BODIES OF CONDUIT. REMOVE STONES AND SHARP OBJECTS TO AVOID POINT
LOADING.
21.1. FOR PIPES AND CONDUIT 6 INCHES OR LARGER IN NOMINAL DIAMETER, SHAPE BOTTOM OF TRENCH TO SUPPORT BOTTOM 90 DEGREES
OF PIPE CIRCUMFERENCE. FILL DEPRESSIONS WITH TAMPED SAND BACKFILL.
21.2. WHERE ENCOUNTERING ROCK OR ANOTHER UNYIELDING BEARING SURFACE, CARRY TRENCH EXCAVATION 6 INCHES BELOW INVERT
ELEVATION TO RECEIVE BEDDING COURSE.
21.3. CONDUIT BEDDING SHALL BE COMPRISED OF BEACH SAND. OTHER UTILITIES/PIPING SHALL UTILIZE D-1 AGGREGATE BASE COURSE FOR
BEDDING.
22. RECONSTRUCT SUBGRADES DAMAGED BY FREEZING TEMPERATURES, FROST, RAIN, ACCUMULATED WATER, OR CONSTRUCTION ACTIVITIES, AS DIRECTED BY THE OWNER'S REPRESENTATIVE, AT NO ADDITIONAL COST TO THE OWNER.
23. STOCKPILE EXCAVATED MATERIALS ACCEPTABLE FOR BACKFILL AND FILL SOIL MATERIALS, INCLUDING ACCEPTABLE BORROW MATERIALS.
STOCKPILE SOIL MATERIALS WITHOUT INTERMIXING. PLACE, GRADE, AND SHAPE STOCKPILES TO DRAIN SURFACE WATER.
24. CONTRACTOR SHALL PROVIDE DETECTABLE WARNING TAPE MADE FROM ACID- AND ALKALI-RESISTANT POLYETHYLENE FILM TO MARK AND IDENTIFY UNDERGROUND UTILITIES. TAPE SHALL BE 6 INCHES WIDE AND 4 MILS THICK, CONTINUOUSLY INSCRIBED WITH A DESCRIPTION OF THE UTILITY, WITH A METALLIC CORE ENCASED IN A PROTECTIVE JACKET FOR CORROSION PROTECTION, DETECTABLE BY METAL DETECTOR WHEN TAPE IS BURIED UP TO 12" DEEP OVER NON FERROUS PIPE. PROVIDE TAPE COLORS TO MATCH UTILITIES AS FOLLOWS:
24.1. RED:....................ELECTRIC
24.2. ORANGE:...........FIBER AND OTHER COMMUNICATIONS
24.3. BLUE:.................WATER SYSTEMS
25. UTILITY TRENCH BACKFILL: PLACE AND COMPACT INITIAL BACKFILL OF SATISFACTORY SOIL MATERIAL OR SUBBASE MATERIAL, FREE OF PARTICLES LARGER THAN 1 INCH, TO A HEIGHT OF 12 INCHES OVER THE UTILITY PIPE OR CONDUIT.
26. CAREFULLY COMPACT MATERIAL UNDER PIPE HAUNCHES AND BRING BACKFILL EVENLY UP ON BOTH SIDES AND ALONG THE FULL LENGTH OF
UTILITY PIPING OR CONDUIT TO AVOID DAMAGE OR DISPLACEMENT OF UTILITY SYSTEM.
27. PLACE AND COMPACT FINAL BACKFILL OF SATISFACTORY SOIL MATERIAL TO FINAL SUBGRADE.
28. WHEN SUBGRADE OR EXISTING GROUND SURFACE TO RECEIVE FILL HAS A DENSITY LESS THAN THAT REQUIRED FOR FILL, BREAK UP GROUND SURFACE TO DEPTH REQUIRED, PULVERIZE, MOISTURE-CONDITION OR AERATE SOIL AND RECOMPACT TO REQUIRED DENSITY.
29. PROTECT NEWLY GRADED AREAS FROM TRAFFIC, FREEZING AND EROSION. KEEP FREE OF TRASH AND DEBRIS.
30. DISPOSAL: TRANSPORT SURPLUS SATISFACTORY SOIL TO DESIGNATED STORAGE ON THE OWNER'S PROPERTY. STOCKPILE OR SPREAD SOIL AS DIRECTED BY THE OWNER'S REPRESENTATIVE. REMOVE WASTE MATERIAL, INCLUDING UNSATISFACTORY SOIL, TRASH AND DEBRIS AND
LEGALLY DISPOSE OF IT OFF THE OWNER'S PROPERTY.
31. EARTHWORK SHALL BE PERFORMED IN ACCORDANCE WITH APPLICABLE PORTIONS OF SECTION 203 OF THE ALASKA DOT AND PUBLIC
FACILITIES STANDARD SPECIFICATIONS FOR HIGHWAY CONSTRUCTION.
SURVEY
1. EXISTING SITE CONDITIONS SHOWN ARE BASED ON A TOPOGRAPHIC SURVEY BY WILLMAN LAND SURVEYING, DATED 04-13-23. THE
CONTRACTOR SHALL FIELD VERIFY EXISTING SITE INFORMATION SHOWN ON THE SURVEY PRIOR TO CONSTRUCTION.
a. VERTICAL CONTROL: ELEVATIONS ARE BASED ON NAVD 88 DATUM.
b. HORIZONTAL CONTROL: BASED UPON NAD83 ALASKA STATE PLANE, ZONE 5, US FOOT.
2. THE CONTRACTOR IS RESPONSIBLE FOR ESTABLISHING HORIZONTAL AND VERTICAL CONTROL FOR SITE CONSTRUCTION AND SHALL HIRE A SURVEYOR LICENSED IN THE STATE OF ALASKA. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF SURVEY MONUMENTATION. DISTURBED SURVEY MONUMENTATION SHALL BE REPLACED BY A SURVEYOR LICENSED IN THE STATE OF ALASKA AT THE
CONTRACTOR'S EXPENSE.
3. THE CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS INCLUDING THE SIZES, LOCATIONS AND ELEVATIONS OF ITEMS THAT AFFECT THE WORK. PRIOR TO THE START OF WORK, REPORT VARIATIONS TO THE OWNER'S REPRESENTATIVE.
UTILITIES
1. PROVIDE THE FOLLOWING TYPES OF PIPES AND TUBES, AS APPLICABLE.
a. DUCTILE-IRON PIPE: AWWA C151, CLASSES 150, 200 AND 250.
b. LINING: AWWA C104, CEMENT MORTAR, SEAL COATED.
c. GASKETS, GLANDS, BOLTS AND NUTS: AWWA C110. FUEL RESISTANT TYPE.
d. PIPE MARKING: NSF 14, "NSF-PW" OR "NSF-PVC CTO ONLY."
2. GATE VALVES SHALL BE NONRISING STEM, AWWA C509, RESILIENT SEATED; BRONZE STEM, CAST-IRON OR DUCTILE-IRON BODY AND BONNET, STEM NUT, 200-PSIG WORKING PRESSURE, FLANGED ENDS.
3. DUCTILE-IRON PIPE SHALL BE INSTALLED ACCORDING TO AWWA C600 AND AWWA M41.
4. MAINTAIN A MINIMUM 5' OF COVER ABOVE DUCTILE IRON PIPING
RANGE RADIO EQUIPMENT BUILDINGRREB
ANTENNA FIELD UTILITY BUILDINGAFUB
MAINTENANCE SUPPORT FACILITYMSF
JOINT
LATITUDE
LENGTH
JUNCTION BOX
LONGITUDE
LOW POINT
LINEAR FEET
KODIAK ELECTRIC ASSOCIATION
LAUNCH PAD 1
JT
KEA
JB
LAT
L
LONG
LP
LF
LP1
ADD ADDITIVE, ADDENDUM
ADJ
ALT
AL
ASTM
ADOT/PF
AT
APPROX
ARCH
ASSY
AVG
ASPH CONC
ADJACENT
ALTERNATE
ALUMINUM
APPROXIMATELY
ARCHITECTURAL
ASPHALTIC CONCRETE
ASSEMBLY
AVERAGE
AND PUBLIC FACILITIES
ALASKA DEPARTMENT OF TRANSPORTATION
AMERICAN SOCIETY FOR TESTING MATERIALS
MATERIAL
MAXIMUM
MAINTENANCE
MANUFACTURER
MECHANICAL
MINIMUM
NORTH
MISCELLANEOUS
NOT APPLICABLE
MECHANICAL JOINT BY PLAIN END
NUMBER
OPENING
NOT TO SCALE
ON CENTER
OVERHEAD
OUTSIDE DIAMETER
PAVEMENT
ORIGINAL
PAYLOAD PROCESSING FACILITY
NOT IN CONTRACT
MAINT
MFR
MATL
MAX
MECH
MJxMJ
MIN
MISC
N N/A
MJxPE
NTS
NO
OPNG
OC
OH
OD
PVMT
PPF
ORIG
NIC
POINT
POINT OF TANGENCY
POINT OF CURVATURE
POINT OF INTERSECTION
POINT OF REVERSE CURVE
POINT OF VERTICAL INTERSECTION
POST INDICATOR VALVE
POUNDS PER SQUARE FOOT
POUNDS PER SQUARE INCH
PLAIN END BY PLAIN END
POLYVINYL CHLORIDE PIPE
REDUCER
RADIUS
POWER POLE
REQUIRED
ROAD
RIGHT
REVISED, REVISION
REINFORCED
REFERENCE, REFUSAL
POWER
PNT
PC
PI
PRC
PExPE
PVI
PVC
PIV
PSF
PSI
PT
PP
RED
R
REF
REQ'D
REV
RD
RT
REINF
P
PERFORATEDPERF
BH
BL
BRG
BM
BIT
BO
BOT
BLDG
BLK
BORE HOLE
BASE LINE
BEARING
BENCH MARK
BITUMINUOUS
BLOCK
BLOW OFF
BOTTOM
BUILDING
CL
CO
CV
CHD
CLF
CONC
CONN
CONST
CJ
CONT
COL
CENTERLINE
CHECK VALVE
CHORD
COLUMN
CONCRETE
CONNECTION
CONSTRUCTION
CONSTRUCTION JOINT
CONTINUOUS
CHAIN LINK FENCE
CENTRAL ANGLED
COORD
CPEP
CU FT
CFM
CFS
CY
CRV
DEPT
DET
CU IN
COORDINATE
CUBIC FEET
CUBIC FEET PER MINUTE
CUBIC FEET PER SECOND
CUBIC INCH
CUBIC YARD
CURVE
DEPARTMENT
DETAIL
DIA
DIM
DIV
DBL
DS
EA
E
ELEC
DIP
DWG
DIAMETER
DIMENSION
DIVISION
DOUBLE
DOWNSPOUT
DRAWING
EACH
EAST
ELECTRIC
DUCTILE IRON PIPE
DIAG DIAGONAL
CONTR CONTRACTOR
CLEANOUT, CHANGE ORDER
CORRUGATED POLYETHYLENE PIPE
MECHANICAL JOINT BY MECHANICAL JOINT
SECTION
SCHEDULE
SANITARY SEWER
SLOPE
SOUTH
SQUARE
SPECIFICATION
SQUARE FEET
SHEET
TRANSFER STRUCTURE
SPACECRAFT AND ASSEMBLIES
STATION
STANDARD
STORAGE
STEEL
STORM DRAIN
SYMBOL
SYSTEM
TANGENT
TELEPHONE
SURFACE
SQUARE INCH
SECT
SCAT
SS
SCHED
SLP
S
SPEC
SQ
SF
SH
STD
STA
STL
STOR
SD
SYM
SYS
TAN
TEL
SURF
SQ IN
THICK
THROUGH
TYPICAL
UNITED STATES COAST GUARD
VERTICAL
VOLUME
WATER
UNLESS NOTED OTHERWISE
UNDERGROUND ELECTRICAL
WITH
WITHOUT
WATER METER, WATER MAIN
THK
THRU
TYP
UGE
USCG
VERT
VOL
W
UNO
W/ W/O
WM
TEMP TEMPORARY
EJ
EQUIP
EXIST
FF
FPS
FHA
FLXFL
FT
FINISH FLOOR
FEET PER SECOND
FEET
EXPANSION JOINT
EQUIPMENT
EXISTING
FM
FLR
FL
FTG
FDN
GCI
GPD
GPS
GALV
FUT
FORCE MAIN
FLOOR
FLOW LINE
FOOTING
FOUNDATION
FUTURE
GALLONS PER DAY
GALLONS PER SECOND
GALVANIZED
FLXPE
GSP
GV
GEN
GRD
GND
HD
HDCP
HB
HP
HORIZ
HDR
GALVANIZED STEEL
GATE VALVE
GENERAL
GRADE
GROUND
HEAD
HANDICAP
HOSE BIB
HORIZONTAL
HEADER
IPF
IN
INFO
ID
INV
INCH
INFORMATION
INSIDE DIAMETER
INVERT
GIP GALVANIZED IRON PIPE
INTEGRATION AND PROCESSING FACILITY
GCI COMMUNICATION CORPORATION
FIRE HYDRANT ASSEMBLY
HIGH POINT, HORSEPOWER
FLANGED JOINT BY FLANGED JOINT
FLANGED JOINT BY PLAIN END
EL
SAN
ELEVATION
SANITARY
NEWDESCRIPTION
STORM DRAIN
CONTOUR
FENCE
SPOT ELEVATION
POWER/COMMUNICATIONS VAULT
EXISTING
PRESSURE CONTROL VALVEPCV
HDPE HIGH DENSITY POLYETHYLENE
LEGEND
ABBREVIATIONS
AAC ALASKA AEROSPACE CORPORATION
IW INDUSTRIAL WASTE
LAUNCH PAD 2 (SUBORBITAL)LP2
LAUNCH PAD 3LP3
VEHICLE PROCESSING FACILITYVPF
ROCKET MOTOR STORAGE FACILITYRMSF
ROCKET STAGING FACILITYRSF
PACIFIC SPACEPORT COMPLEX ALASKAPSCA
NOTE: ALL ABBREVIATIONS SHOWN MAY NOT APPEAR IN THE DRAWINGS.
NATIONAL WETLANDS INVENTORYNWI
UTILITYUTIL
LIFE SUPPORT AREALSA
SILT FENCE
DEMOLITION
STOCK PILE
CONCRETE
AGGREGATE SURFACE
DOT DEPARTMENT OF TRANSPORTATION
RIP RAP
CONCRETE
1.
2. CONCRETE SHALL BE NORMAL WEIGHT CONCRETE EXCEPT AS NOTED. ALL CONCRETE STRENGTHS (AT 28 DAYS) SHALL BE AS
FOLLOWS:
FOUNDATIONS & SLABS ON GRADE 4500 PSI
CONCRETE WORK SHALL COMPLY WITH PROVISIONS OF ACI 318-19, ACI 315-18, AND ACI 301-16, AND THE INTERNATIONAL
BUILDING CODE 2021.
SLABS (CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH) 3 INCHES
STRUCTURAL ELEMENT CLEAR COVER
CONCRETE PROTECTION FOR REINFORCING BARS:4.
3. CALCIUM CHLORIDE SHALL NOT BE USED IN ANY FORM.
5.
REINFORCING STEEL SHALL BE PLACED WITHIN TOLERANCES SPECIFIED IN SECTIONS 7.5.2.1 AND 7.5.3.3 IN ACI 315-18.
6. TOP BARS ARE HORIZONTAL REINFORCEMENT PLACED SO THAT MORE THAN 12" OF FRESH CONCRETE IS CAST BELOW THE
BAR.
REINFORCING LAP SPLICE TABLE:
REINFORCING FOR CONTINUOUS FOUNDATIONS SHALL BE CONTINUOUS AT CORNERS AND INTERSECTIONS. PROVIDE CORNER LAP BARS AT CORNERS AND INTERSECTIONS. CORNER BARS SHALL HAVE LAP LENGTHS EQUAL TO THE STRAIGHT BAR LAP LENGTHS ON BOTH ENDS OF THE CORNER BARS. WHERE CONTINUOUS FOUNDATIONS INTERSECT COLUMN FOUNDATIONS, REBAR FROM CONTINUOUS FOUNDATION SHALL BE CONTINUOUS THROUGH 6'-0" AND SMALLER COLUMN FOUNDATIONS, AND SHALL EITHER BE CONTINUOUS THROUGH, OR EXTEND A MINIMUM OF 2'-6" (BUT NOT LESS THAN THE STRAIGHT BAR DEVELOPMENT LENGTH) INTO COLUMN FOUNDATIONS LARGER THAN 6'-0" WIDE.
REINFORCEMENT SHALL BE BENT COLD. REINFORCEMENT PARTIALLY EMBEDDED IN CONCRETE SHALL NOT BE FIELD BENT UNLESS APPROVED BY THE STRUCTURAL ENGINEER OF RECORD. HOOKS SHALL BE ACI STANDARD HOOKS IN
ACCORDANCE WITH CHAPTER 7 IN ACI 318. SEE REQUIRED EMBEDMENT CHARTS BELOW.
8.
9.
IT IS PERMITTED TO SUBSTITUTE MECHANICAL SPLICES (MEETING THE REQUIREMENTS OF SECTION 25.5.7 IN ACI 318-19) FOR LAP SPLICES AT NO ADDITIONAL COST. MECHANICAL SPLICES SHALL DEVELOP 125% (MIN) OF THE YIELD STRENGTH OF THE
REBAR IN TENSION OR COMPRESSION.
7.
DEFORMED
REBAR TYPE
MINIMUM INSIDE DIAMETER OF BEND
#3 #4 #5 #6 #7 #8 #9 #10
STIRRUPS & TIES 1.5" 2" 2.5" NA NA NA NA NA
OTHER BARS 2.25" 3" 3.75" 4.5" 5.25" 6" 9" 10.25"
DESCRIPTION
ACI MINIMUM STANDARD HOOK EXTENSION LENGTHS
#3 #4 #5 #6 #7 #8 #9 #10
STIRRUPS & TIES
2.5" 3" 3.75" NA NA NA NA NA
90° BEND PLUS
STIRRUPS & TIES
2.5" 3" 3.75" NA NA NA NA NA
135° BEND PLUS
OTHER BARS
4.5" 6" 7.5" 9" 10.5" 12" 13.75" 15.5"
90° BEND PLUS
OTHER BARS
2.5" 2.5" 2.5" 3" 3.5" 4" 4.75" 5.25"
180° BEND PLUS
AT THE TIME CONCRETE IS PLACED, REINFORCEMENT SHALL BE FREE FROM MUD, OIL OR OTHER NONMETALLIC COATINGS
THAT DECREASE BOND.
10.
LAP SPLICE LENGTH (4500 PSI CONCRETE) - NORMAL WEIGHT, NO EPOXY
BAR SIZES (#)
TO
P
BA
RS
OT
HE
R
3 4 5 6 7 8 9 10
3" 15" 20" 24" 29" 42" 48" 55" 65"
2" 15" 20" 24" 29" 46" 61" 77" 97"
1 1/2" 15" 20" 25" 36" 62" 81" 102" 130"
3/4" 18" 32" 50" 73" 106" 121" 136" 153"
3"
2"
1 1/2"
3/4"
12" 15" 19" 23" 33" 37" 42" 50"
12" 15" 19" 23" 36" 47" 59" 75"
12" 15" 20" 28" 48" 62" 79" 100"
14" 25" 39" 56" 81" 93" 105" 118"
80"
120"
160"
170"
62"
92"
123"
131"
REQUIRED EMBEDMENT DEPTH OF STANDARD ACI HOOKS INTO CONCRETE
CONCRETE TYPE
BAR SIZES (#)
3 4 5 6 7 8 9 10 11
4500 PSI 8" 10" 12" 15" 17" 19" 22" 25" 27"NORMAL
WEIGHT
#11
NA
NA
17"
5.75"
#11
NA
11.5"
LEAST CONCRETE
COVER AT BAR
WELDABLE DEFORMED REBAR (WHERE INDICATED): FY = 60 KSI (A706, GRADE 60)
DEFORMED REBAR (TYP UNO): FY = 60 KSI (A615, GRADE 60)
COTR CONTRACTING OFFICERS' TECHNICAL REPRESENTATIVE
CUTS, HOLES AND THEIR REINFORCEMENT (REQUIRED BY OTHER TRADES) SHALL BE SHOWN ON THE STRUCTURAL STEEL SHOP DRAWINGS AND SHALL BE MADE IN THE SHOP. FIELD BURNING OF HOLES & CUTS IN STRUCTURAL STEEL SHALL NOT BE PERMITTED EXCEPT BY WRITTEN PERMISSION FROM THE STRUCTURAL ENGINEER OF RECORD, UNLESS NOTED
OTHERWISE ON THE DRAWINGS.
7.
6.
5.
4.
3. STRUCTURAL STEEL SHALL HAVE THE FOLLOWING ASTM SPECIFICATION AND YIELD STRENGTHS UNO:
PLATE STEEL FY = 36 KSI (A36)
DETAILING, FABRICATION AND ERECTION SHALL CONFORM TO THE LATEST EDITION OF THE AISC STEEL CONSTRUCTION
MANUAL.
FILLET WELDS SHALL BE 3/16" UNO, BUT NOT LESS THAN AISC MINIMUM, SEE CHART BELOW:
WELDING ELECTRODES SHALL BE E70XX, UNO. WELDING SHALL BE PERFORMED BY AWS CERTIFIED WELDERS AND
SHALL CONFORM TO AWS D1.1/D1.1M STRUCTURAL WELDING CODE - STEEL, LATEST EDITION.
THE FABRICATOR SHALL FURNISH A STRUCTURAL SUBMITTAL WHICH SHALL BE CHECKED BY THE CONTRACTOR FOR COMPLETENESS AND CONTENT PRIOR TO SUBMITTAL TO THE STRUCTURAL ENGINEER OF RECORD FOR REVIEW. THE SUBMITTAL SHOULD INCLUDE FABRICATION AND ERECTION DRAWINGS. FABRICATION SHALL NOT COMMENCE UNTIL THIS
REVIEW IS COMPLETED.
MINIMUM SIZE FOR FILLET WELDS
MATERIAL THICKNESS OF THINNER
PART JOINED (INCHES)
TO 1/4" INCLUSIVE
MINIMUM SIZE OF
FILLET WELD (INCHES)
1/8"
OVER 1/4" TO 1/2" 3/16"
OVER 1/2" TO 3/4" 1/4"
OVER 3/4" 5/16"
10.
9. SIZE AND SHAPE OF STRUCTURAL STEEL SHALL BE AS SHOWN ON DRAWINGS. SUBSTITUTES MAY BE USED IF PRE-
APPROVED IN WRITING BY THE STRUCTURAL ENGINEER OF RECORD.
8.
1. DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL SHALL BE IN ACCORDANCE WITH THE AISC STEEL CONSTRUCTION MANUAL, 14TH EDITION. THE STRUCTURAL FRAME FABRICATOR SHALL BE AISC CERTIFIED FOR STEEL BUILDING STRUCTURES (STD) OR INCLUDE, AT THE FABRICATORS EXPENSE, INSPECTION SERVICES NECESSARY TO INSURE THAT THE SHOP PROCEDURES AND FABRICATION COMPLIES WITH DRAWINGS AND SPECIFICATIONS. SPECIFICALLY, BOLTED AND WELDED CONNECTIONS FOR TRUSSES, MOMENT CONNECTIONS AND VERTICAL BRACED FRAME COMPONENTS SHALL BE INSPECTED AND TESTED BY A CERTIFIED TESTING AGENCY RETAINED BY THE FABRICATOR. COMPLIANCE REPORTS
SHALL BE SENT TO THE STRUCTURAL ENGINEER OF RECORD.
PROVIDE 3" MINIMUM CONCRETE COVER AROUND STEEL BELOW GRADE OR COATED WITH ASPHALTIC OR BITUMASTIC PAINT.2.
11.
WELDING WORK SHALL FOLLOW INFORMATION IN AN APPROVED WELDING PROCEDURE SPECIFICATION SUPPORTED BY A PRE-QUALIFICATION RECORD, FOLLOWING REQUIREMENTS IN THE CURRENT BUILDING CODE ADOPTED VERSION OF THE AMERICAN WELDING SOCIETY (AWS) D1.1 - STRUCTURAL WELDING CODE STEEL. WELDING WORK SHALL BE PERFORMED BY WELDERS CERTIFIED TO PERFORM WELDING WORK IN ACCORDANCE WITH THE GOVERNING WPS.
STEEL SHALL BE HOT DIPPED GALVANIZED
STRUCTURAL STEEL:
BRPH
BRPH
BRPH
RANGE CONTROL CENTERRCC
SAWCUT JOINT, FILL WITH SEALANT,
SEE DETAIL 4 ON THIS SHEET
8"
3"
CONCRETE SLAB REINFORCED
WITH #6 @ 24" O.C. EACH WAY
SUBGRADE, PLACED IN MAXIMUM 9" LOOSE LIFTS AND
COMPACTED TO 95 PERCENT MAXIMUM
DRY DENSITY PER ASTM D 1557 (MODIFIED PROCTOR)
FINISHED GRADE
3"
BRACE RAILS 3/8" DIA TRUSS ROD
LINE POST
6"
3'- 0"
10'-0" MAX SPACING
TYPICAL DOUBLE SWING GATE ELEVATION
2"
POST CAPTOP RAIL
BRACE RAILS3/8" DIA TRUSS ROD
LINE POST
6" 3'-
0"
10'-0" MAX SPACING
2"
GATE HINGE WITH OPPOSING BARREL
PINS.
GATE HINGE WITH OPPOSING
BARREL PINS
GATE HINGE WITH OPPOSING
BARREL PINS
PLAN - DOUBLE SWING GATE
STANDARD GATE LATCH. SEE
SPECIFICATIONS
3"
CHAIN LINK FABRIC
(TYPICAL)
BARBED WIRE
PROVIDE CONCRETE FOOTING.
DIAMETER OF FOOTING SHALL BE
4X POST DIAMETER (TYP UON)
TIE WIRES (TYP) ALONG TOP RAILS
AND POSTS
GATE POST (TYP UON)
3/8" DIA TRUSS
ROD (TYP UON)
GATE UPRIGHT FOR
FRAME (TYP UON)
SEE PLANS
7'
- 0
2'- 0"
2'- 0"
1'-4" 1'-4"
POST CAP
6" 3'-
0"
2"
POST CAP
2"
PLAN PEDESTRIAN GATE
3/8" DIA TRUSS
ROD (TYP UON)
TOP RAIL
(TYP UON)
BRACE RAILS (TYP UON)
GATE HINGE WITH OPPOSING
BARREL PINS.
3/8" DIA TRUSS
ROD (TYP UON)
KEYED ACCESS ON THE
UNSECURED SIDE OF GATE
SEE PLANS
7'-
2'
- 0
1'
- 0
1'-4"
HORIZONTAL
BRACE
D1
D1
30' 15'
P:
\C
5.0
.00
AA
C
- A
RE
A 3 P
AD
C
R
EB
UI
LD
EN
G
SU
PP
OR
T\
SH
EE
TS
\C -5
.D
W G
5/1 7/2
4 1
1:3 9 A
M
BRPH
BRPH
BRPH
C06885.030.00
DETAILS
C-501 54321 6
A
B
C
D
E
Architects Engineers, Inc.
These plans are protected by Federal Copyright protection. Unauthorized use may result in an infringement action.
www.brph.com Copyright © 2024
19020 33rd Ave W| Suite 500 Lynnwood | Washington | 98036 425-255-1095
Professional Licensing Division: AECC736
Offices in Melbourne, Orlando, Atlanta, Boca Raton, Lynnwood, and Charleston
DOCUMENT HISTORY
RECORD DOCUMENTS
REV DATE DESCRIPTION
AR
EA
P
AD
C
R
EB
U
IL
D N
A
RR
O W
C A
PE
KO
D
IA
K
IS
LA
N D
A
LA
SK
A
AL
AS
KA
A
ER
O
SP
AC
E
CO
RP
O
RA
TI
O N
DRAWING NO.
TITLE
PROJECT NUMBER
DRAWN BY
DESIGNED BY
ARCH/ENGR OF RECORD
DATE
05/09/2024
R
EC ORD
D
RA W IN
G
LOOP GEOTEXTILE FABRIC
OVER POSTS AND WIRE
FASTENER
WOVEN WIRE FENCE
GEOTEXTILE FABRIC
POST
COMPACTED SOIL
GRADE
FLOW
" M
IN
" M
IN
6" M
IN
. 6" MIN
GROUND LINE
HOG WIRE FASTENERS EVERY 2 FT.
TRENCH 8" MIN.
" M
IN
" M
IN
4' O.C.
STEEL POSTS
WOVEN WIRE
FENCE BACKING
FRONT VIEW
(NTS)
SIDE VIEW
(NTS)
NOTES:
1. WOVEN WIRE FENCE SHALL BE A MINIMUM 14 GAUGE, 6" x 6"
2. WOVEN WIRE FENCING SHALL BE FASTENED TO THE UPSTREAM SIDE OF POSTS BY STAPLES OR WIRE TIES.
3. GEOTEXTILE FABRIC SHALL BE SECURELY FASTENED TO THE WOVEN WIRE FENCING.
4. MACHINE TRENCHED GEOTEXTILE SHALL BE TRENCHED VERTICAL AT LEAST 8" DEEP.
8"
8 SILT FENCING DETAIL
N.T.S.C-101 C-500
1 PROPELLANT STORAGE SLAB DETAIL
N.T.S.C-141 C-501
3/4"
3/8
3/8
POURED JOINT SEALANT,
SEE NOTE 1
PAVEMENT SURFACE
SAWED JOINT FACE
1" BACKER ROD
3/4" JOINT FILLER
2" T
O 2-
3/8
4 JOINT SEAL DETAIL (NIC, FUTURE)
N.T.S.C-501 C-501
NOTES:
1. JOINT SEALANT SHALL BE SIKAFLEX-2C BY SIKA, CEILCOTE CJ3 BY INTERNATIONAL, OR EQUIVALENT.
2 FUEL PAD JOINTING PLAN (NIC, FUTURE)
N.T.S.C-141 C-501
3 PLANE OF WEAKNESS JOINT (D1) DETAIL
N.T.S.C-141 C-501
0'- 2"
BARBED WIRE GALVANIZED
3 STRANDS, 4 POINT
1'- 0"
1'-0"
END BAY 10'-0" ORMULTIPLES OF 10'-0"
0'- 6"
7'- 0"
0'- 6"
15" CONCRETE
LINE POST
CORNER BAY
18" CONCRETE
CORNER POST
WIRE TIES
FABRIC
CHAIN LINK
(3/8" MIN)
TRUSS ROD
BAR
STRETCHER
BRACE
CHAIN LINK FENCE W/ BARBED WIRE
7 GA. TENSION WIRE
OVERBURDEN
BEDROCK
3'- 0"
TY
P
2'- 0"
NOTES:
1. CONCRETE SHALL BE 4,500 PSI COMPRESSIVE STRENGTH.
2. GALVANIZED STEEL WOVEN WIRE FABRIC TO BE STRETCHED TAUT WITH STRETCHER BARS & STRAPS AND
FASTENED TOP & BOTTOM AND AT LINE POSTS WITH GALV PIG RING TIES.
3. INSTALL TEMPORARY GUYS OR BRACES AS REQUIRED TO HOLD POSTS IN PROPER POSITION UNTIL
CONCRETE HAS SET SUFFICIENTLY TO HOLD POSTS.
OR BRACE RAIL
3/8" MINIMUM
TRUSS ROD
CONCRETE BASE
CLAMP FOR TOP
TRUSS ROD AND BAND
SECURELY FASTENED TOGETHER
OR COLUMN AND ENDS SHALL BE
MUST COMPLETELY ENCIRCLE POST
FABRIC TIES, CLAMPS OR BANDS
NOTE:
WIRE TIES FOR POSTS
BAND FOR WIRE STRETCHING
PLAN AT BANDS
DETAIL - END OR GATE POST
STRETCHER BAR
SPACED 15" O.C. MAX.
TOP AND BOTTOM AND
TO BE 4" MAX. FROM
STRETCHER BAR BAND
LINK
ENGAGE EACH FABRIC
STRETCHER BAR TO
FABRIC
CARRIAGE BOLT
(WIRE SIMILAR)
EACH SIDE (SPACE 2'-0" MAX.
WIRE TIES CLOSE TO POST
AS RECOMMENDED BY MFR.
TAUT AND FASTEN SECURELY
3 STRANDS BARBED WIRE-PULL
POINT OUTWARD AT A 45° ANGLE
PRESSED STEEL OR WROUGHT IRON
EXTENSION ARMS TO BE 12 GAGE
ON INSIDE OF FENCE
POSITIVE FASTENING
OTHER APPROVED
THRU BOLT OR
FABRIC
TOP RAIL
7 PEDESTRIAN GATE DETAIL
N.T.S.C-141 C-501
6 DOUBLE LEAF SWING GATE DETAIL
N.T.S.C-141 C-501
5 CHAIN LINK FENCING DETAILS
N.T.S.C-141 C-501
1. FABRIC: THE STANDARD FENCE FABRIC SHALL BE GALVANIZED ZINC WIRE CHAIN LINK WITH MESH OPENINGS NOT LARGER THAN TWO INCHES PER SIDE AND A TWISTED AND BARBED SELVAGE AT TOP AND BOTTOM.
2. FABRIC TIES: ONLY 11-GAUGE STEEL TIES SHALL BE USED. COATING OR PLATING WILL BE
ELECTROLYTICALLY COMPATIBLE WITH THE FENCE FABRIC TO INHIBIT CORROSION.
3. REINFORCEMENT: TENSION WIRES SHALL BE INSTALLED AND INTERWOVEN (OR AFFIXED WITH FABRIC TIES)
ALONG THE TOP & BOTTOM OF THE FENCE FOR STABILIZATION OF THE FENCE FABRIC.
4. FENCE HEIGHT: CHAIN LINK FABRIC SHALL BE 7' HIGH WITH AN ADDITIONAL 1' IN HEIGHT COMPOSED OF 3
STRANDS OF BARBED WIRE.
5. GROUND CLEARANCE: BOTTOM OF THE FENCE FABRIC SHALL BE WITHIN TWO INCHES OF FIRM GRADE.
6. TOP GUARDS: A TOP GUARD IS AN OVERHANG OF BARBED WIRED ALONG THE TOP OF A FENCE, FACING OUTWARD (AWAY FROM PROTECTED SITE) AND UPWARD AT APPROX. 45 ANGLE. TOP GUARD SUPPORTING ARMS WILL BE PERMANENTLY AFFIXED TO THE TOP OF FENCE POSTS TO INCREASE THE OVERALL HEIGHT OF THE FENCE AT LEAST 1 FOOT. THREE STRANDS OF 12-GAUGE BARBED WIRE, EQUALLY SPACED, SHALL BE
INSTALLED ON THE SUPPORTING ARMS.
7. FENCE POSTS: SHALL BE ASTM F1043 OR F1083 ROUND PIPE AND SHALL BE GALVANIZED IN ACCORDANCE WITH THE SPECIFICATIONS. FENCE POST SPACING AND SIZE (DIAMETER) SHALL BE DETERMINED IN ACCORDANCE WITH CHAIN LINK FENCE MANUFACTURERS' INSTITUTE (WLG 2445). SPACING SHALL NOT
EXCEED 10'-0" OC. SIZE (DIAMETER) SHALL NOT BE LESS THAN THAT SPECIFIED.
CHAIN LINK FENCING NOTES
N
NOTES:
1. FOR STRUCTURAL PERFORMANCE OF CHAIN LINK FENCE, FOUNDATIONS AND GATE FRAMEWORKS, CONTRACTOR SHALL PROVIDE SHOP DRAWINGS SIGNED AND SEALED BY AN ALASKA REGISTERED P.E..
NOT PERFORMED.
15" 18"
THIS WORK EXCEPT CONCRETE WAS
PERFORMED UNDER A SEPARATE
FENCING CONTRACT, NOT PART OF THE
PHASE 1 CIVIL WORKS.
NOTE: STANDARD LOCKABLE GATE HASP PROVIDED.
NOTE: BY PHASE 1 CIVIL WORKS CONTRACTOR.
(NIC, FUTURE)
| Sheets and Views |
| G-001 COVER SHEET |
| PLOT-42x30 |
| PLOT-36x24 |
| PLOT-34x22 |
| PLOT-17x11 |
| PLOT-11x17 |
| PLOT-11x8.5 |
| PLOT-8.5x11 |
| PLOT-48x36 |
| PLOT-40x28 |
| C-001 CIVIL GENERAL NOTES, LEGEND & ABBREVIATIONS |
| PLOT-42x30 |
| PLOT-36x24 |
| PLOT-34x22 |
| PLOT-17x11 |
| PLOT-11x17 |
| PLOT-11x8.5 |
| PLOT-8.5x11 |
| PLOT-48x36 |
| PLOT-40x28 |
| C-101 DEMOLITION PLAN |
| PLOT-42x30 |
| PLOT-36x24 |
| PLOT-34x22 |
| PLOT-17x11 |
| PLOT-11x17 |
| PLOT-11x8.5 |
| PLOT-8.5x11 |
| PLOT-48x36 |
| PLOT-40x28 |
| C-141 SITE, GRADING AND DRAINAGE PLAN |
| PLOT-42x30 |
| PLOT-36x24 |
| PLOT-34x22 |
| PLOT-17x11 |
| PLOT-11x17 |
| PLOT-11x8.5 |
| PLOT-8.5x11 |
| PLOT-48x36 |
| PLOT-40x28 |
| C-201 PROFILES |
| C-501 DETAILS |
| PLOT-42x30 |
| PLOT-36x24 |
| PLOT-34x22 |
| PLOT-17x11 |
| PLOT-11x17 |
| PLOT-11x8.5 |
| PLOT-8.5x11 |
| PLOT-48x36 |
| PLOT-40x28 |
C-502 DETAILS