SAJU 256256 087100 - 1
SAJU DOOR LOCKS AND HARDWARE
SECTION 087100 – SAJU DOOR LOCKS AND HARDWARE
PART 1 – GENERAL
1.01 SUMMARY
A. This Section includes the following:
1. Keys.
2. Lock cores.
3. Lock core housings.
4. Mechanical door locks and exit devices.
5. Electrified door locks and exit devices.
6. Electrified door strikes.
7. Door hardware.
1.02 SUBMITTALS
A. Product Data: For each type of product indicated.
B. Product certificates and test reports.
C. Shop Drawings: Details of electrified door hardware, including wiring diagrams.
D. Keying Schedule: Schedule of door lock locations and planned installation configuration.
E. Project Schedule: Schedule of project tasks and timeframes.
1.03 QUALITY ASSURANCE
A. Installer Qualifications: An Installer is an employer of workers trained and approved by lock manufacturer.
1. The Installer is responsible for supplying and installing keys, locks, exit devices and door hardware.
2. The Installer shall have a minimum of five years of experience specific to installing and servicing lock systems and door hardware.
B. Source Limitations: Provide electrified door hardware from the same manufacturer as existing mechanical door hardware, unless otherwise indicated.
C. Keying Conference: Conduct conference at Project site location to review project tasks and associated timeframes. Incorporate decisions into Project Schedule.
1.04 DELIVERY, STORAGE, AND HANDLING
A. Deliver keys to manufacturer of key control system for subsequent delivery to Owner.
1. San Juan National Historic Site, Law Enforcement Division.
PART 2 - PRODUCTS
2.01 KEYING
A. Keying System: Factory registered, complying with guidelines in BHMA A156.28. Incorporate decisions made in keying conference into master key system.
B. Keys: Nickel silver; permanently inscribed with a visual key type and assigned control number.
Inscribed with "DO NOT DUPLICATE" and “U.S. GOVERNMENT.”
1. Identification: Each key shall be inscribed with key type as identified by Park Keying
Schedule. Each key type series shall be sequentially numbered to provide a unique identifying inscription on each key.
2. Delivery: Keys shall be delivered to the Owner’s Key Management Office.
SAJU 256256 087100 - 2
2.02 LOCK CORE
A. General:
High security lock cylinders provide resistance to picking and drilling defeat. A patented key system provides enhanced protection against unauthorized duplication for a specified period.
B. Requirements:
1. Form Factor: BEST - SFIC Interchangeable Core.
2. Number of Pins: Seven (7) pin.
3. Certifications: BHMA A156.5 Grade 1 certified core. Listed as complying with pick- and drill-resistant testing requirements of UL 437.
4. Utility Patent: 2027 or later.
5. Finish: BEST #626 Satin Chrome.
C. Identification: External face of core inscribed with key control number.
D. Manufacturer:
1. BEST Access; A Stanley Security Company.
E. Products:
1. BEST High Security CORMAX X-Series Core. Substitutions not permitted.
F. Lubricant:
1. Only to be lubricated with General Purpose Dry Lubricant
a. Lubricant Base: Graphite
b. 50 State VOC Compliant
c. VOC Content: 0 %
d. Non-Flammable
2.03 LOCK CYLINDERS
A. Rim Exit Device Lock Cylinder
1. Core Housing: 7-Pin BEST SFIC Interchangeable Core.
2. Cylinder Diameter: 1-5/32”.
3. Finish: BEST #626 Satin Chrome
4. Products: BEST 12E Series.
B. Mortise Exit Device Lock Cylinder
1. Core Housing: 7-Pin BEST SFIC Interchangeable Core.
2. Cylinder Diameter: 1-5/32”.
3. Finish: BEST #626 Satin Chrome.
4. Products: BEST 1E Series.
2.04 MECHANICAL LOCKS
A. Standard Cylindrical Lock:
1. Certifications: ANSI/BHMA A156.13 Series 4000—Grade 1, ANSI A117.1 section 404.2.6, Accessibility Code (ADA compliant), UL listed for three hours on A label doors.
2. Lock Function: Storeroom (D) ANSI F07.
3. Outside Lever: Always Locked, Cannot be Unlocked.
4. Inside Lever: Always Unlocked, Cannot be Locked.
5. Core Housing: 7-Pin BEST SFIC Interchangeable Core.
6. Door Thickness Suitability: 1-3/4” standard, up to 2-1/4” thick.
7. Door Prep: ANSI A115.2.
8. Backset: 2-3/4” Standard, field conditions to be verified by installer.
9. Latch: Deadlocking Stainless Steel 9/16” throw.
10. Strike: BEST 8KS3 type 4-7/8” x 1-1/4” with curved lip.
11. Lever Handle: BEST type 15D with 3-1/2” diameter BEST D type rose.
12. Finish: BEST #626 Satin Chrome.
SAJU 256256 087100 - 3
13. Products: BEST 9K Series Heavy Duty Cylindrical Locks. Substitutions not permitted.
B. Deadbolt Lock:
1. Lock Function: Classroom One-way deadbolt, ANSI E2171.
2. Lock Operation: Turning key in outside cylinder only.
3. Unlock Operation: Turning key in outside cylinder and turning inside turn lever.
4. Core Housing: 7-Pin BEST SFIC Interchangeable Core.
5. Door Thickness: 1-3/4”.
6. Bolt Throw: 1”.
7. Strike: Standard Strike 1-1/8” x 2-3/4”.
8. Finish: BEST #626 Satin Chrome.
9. Products: BEST T Series Tubular Deadbolts. Substitutions not permitted.
C. Standard Mortise Lock:
1. Certifications: ANSI/BHMA A156.13 Series1000—Grade 1, ANSI A117.1 section
404.2.6, Accessibility Code (ADA compliant) UL listed for three hours on A label doors.
2. Lock Function: Storeroom (D) ANSI F07.
3. Outside Lever: Always Locked, Cannot be Unlocked.
4. Inside Lever: Always Unlocked, Cannot be Locked.
5. Core Housing: 7-Pin BEST SFIC Interchangeable Core.
6. Door Thickness Suitability: 1-3/4” standard, up to 5” thick.
7. Door Prep: ANSI Type 86 cutout.
8. Case: 5-7/8” x 7/8” x 4/1/16” Cold Rolled Steel, Zinc plated for corrosion resistance.
9. Backset: 2-3/4” Standard, installer to verify field conditions.
10. Latch: Stainless Steel ¾” throw; Reversible.
11. Strike: Standard Strike and Strike Box ANSI A115.1.
12. Lever Hardware: BEST 15 type lever with type J escutcheon.
13. Finish: BEST #626 Satin Chrome.
14. Products: BEST Heavy Duty Mortise Locks 47H Series. Substitutions not permitted.
D. Secure Mortise Lock:
1. Certifications: ANSI/BHMA A156.13 Series1000—Grade 1, ANSI A117.1 section
404.2.6, Accessibility Code (ADA compliant) UL listed for three hours on A label doors.
2. Lock Function: Dormitory (TD) configured with latch and deadbolt.
3. Outside Lever: Always Locked, Cannot be Unlocked.
4. Inside Lever: Always Unlocked, Cannot be Locked.
5. Core Housing: 7-Pin BEST SFIC Interchangeable Core.
6. Door Thickness Suitability: 1-3/4” standard, up to 5” thick.
7. Door Prep: ANSI Type 86 cutout.
8. Case: 5-7/8” x 7/8” x 4/1/16” Cold Rolled Steel, Zinc plated for corrosion resistance.
9. Backset: 2-3/4” Standard.
10. Latch: Stainless Steel ¾” throw; Reversible.
11. Strike: Latchbolt / Deadbolt strike.
12. Lever Hardware: BEST 15 type lever with type J escutcheon.
13. Finish: BEST #626 Satin Chrome.
14. Products: BEST Heavy Duty Mortise Locks 47H Series. Substitutions not permitted.
E. Rim Exit Device:
1. Certifications: UL 305 Panic Hardware, ANSI/BHMA A156.3-2008 Grade 1.
2. Operation: Mechanical latch retraction
3. Materials: Aluminum.
4. Push Bar Length: Per design requirements.
5. Handing: Non-handed.
6. Door Thickness: 1-3/4” Standard upto 2-1/4”.
7. Stile Width: 2” or Greater.
8. Projection: 2-5/8”.
9. Cylinder: 1-5/32” Rim Cylinder. See Rem Exit Device Lock Cylinder Housing
SAJU 256256 087100 - 4
requirements.
10. Exterior Lever Handle: BEST 15 type lever with type J escutcheon.
11. Finish: Satin Chrome.
12. Warranty: 5 year or Greater
13. Products: Adams Rite 8700 or 8800 Series Rim Exit Device or Approved Equal.
F. Flushbolt Lock:
1. Lock Cylinder: Accepts 1-5/32” diameter mortise cylinder.
2. Cylinder Backset: 1-1/4”.
3. Cylinder Height: 13-1/2”.
4. Bolt: Stainless Steel 3/8” Diameter or Greater.
5. Bolt Throw: 11/16”
6. Finish: Satin Chrome or Stainless Steel.
7. Products: Adams Rite 1870 or Approved Equal.
G. Padlocks:
1. Case: Solid extruded brass.
2. Core Housing: seven (7) pin, BEST SFIC Interchangeable Core.
3. Shackle: Stainless Steel, 1/4” Diameter, Locking at Heal and Toe.
4. Identification: Inscribed with Padlock Number.
5. Finish: BEST 626 Satin Chrome.
6. Products: BEST B Series Padlocks. Substitutions not permitted.
2.05 ELECTRIC LOCKS
A. Electric Mortise Lock
1. Certifications: ANSI/BHMA A156.13—Grade 1, ANSI A117.1, Accessibility Code (ADA compliant), UL 10C listed for three hours on A label doors.
2. Lock Function: Single key latch, Fail-Secure (DEU).
3. Outside Lever: Always Locked, Cannot be Unlocked.
4. Inside Lever: Always Unlocked, Cannot be Locked.
5. Core Housing: 7-Pin BEST SFIC Interchangeable Core.
6. Door Thickness Suitability: 1-3/4” standard, up to 2-1/4” thick.
7. Door Prep: ANSI A115.1 door cutout.
8. Case: 5-7/8” x 7/8” x 4/1/16” Cold Rolled Steel, Zinc plated for corrosion resistance.
9. Backset: 2-3/4” Standard.
10. Latch: Stainless Steel ¾” throw; Reversible.
11. Strike: Standard Latchbolt.
12. Lever Hardware: BEST 15 type lever with type J escutcheon.
13. Finish: BEST #626 Satin Chrome.
14. Products: BEST 40HW Electro-mechanical Mortise Lock. Substitutions not permitted.
B. Electric Mortise Exit Device
1. Certifications: UL 305 Panic Hardware.
2. Operation: Solenoid electric latch retraction.
3. Strike: Standard Latchbolt.
4. Materials: Aluminum
5. Push Bar Length: Per design requirements.
6. Handing: Per design requirements.
7. Door Thickness: 1-3/4” Standard up to 2-1/4”.
8. Stile Width: 2” or Greater.
9. Projection: 2-5/8”.
10. Cylinder: Furnish with 1-5/32” Mortise Exit Device Lock Cylinder.
11. Exterior Lever Hardware: BEST 15 type lever with type J escutcheon.
12. Finish: Satin Chrome.
13. Warranty: 5 year or Greater.
SAJU 256256 087100 - 5
14. Products: Adam Rite 8300 or 8400 Series Rim Exit Device with Electric Latch Retraction (LR) or Approved Equal.
C. Electric Rim Exit Device
1. Certifications: UL 305 Panic Hardware, ANSI/BHMA A156.3-2008 Grade 1.
2. Operation: Solenoid electric latch retraction.
3. Strike: Standard Rim Strike.
4. Materials: Aluminum.
5. Push Bar Length: Per design requirements.
6. Handing: Non-handed.
7. Door Thickness: 1-3/4” Standard.
8. Stile Width: 2” or Greater.
9. Projection: 2-5/8”.
10. Cylinder: Furnish with 1-5/32” Rim Exit Device Lock Cylinder.
11. Warranty: 5 year or Greater
12. Products: Adam Rite 8700 or 8800 Series Rim Exit Device with Electric Latch Retraction
(EL) or Approved Equal.
2.06 ELECTRIC STRIKES
A. Electric Strike for Cylindrical Lock
1. Strike Function: Fail-Secure.
2. Lock Compatibility: Cylindrical, Narrowline Aluminum.
3. Configuration: Low Profile Universal with Monitoring.
4. Construction: Stainless Steel.
5. Faceplate: 1-1/4” W x 4-7/8” H
6. Insert Depth: 1-3/4”.
7. Latch Projection: ½”.
8. Strength: 1500lbf Static or Greater.
9. Certifications: UL 294 Listed for Access Control Unit Accessory (6th Edition) UL 1034 burglary-resistant Listed UL 10C Certified to ANSI/BHMA standard A156.31, Grade 1, endurance 500,000 cycles rated.
10. Power: 12/24VDC Field-selectable.
11. Warranty: 5 year limited
12. Products: BEST 6 Series Centerline Strikes Model# BES-L65ULMKM furnish with Latch
Monitor or Approved Equal. Substitutions permitted based on product properties and compatibility with existing lock systems.
B. Electric Strike for Mortise Lock
1. Strike Function: Fail-Secure.
2. Lock Compatibility: Mortise, Cylindrical, Exit Device.
3. Configuration: Deadbolt Keeper and Deadlatch Ramp.
4. Construction: Stainless Steel.
5. Faceplate: 1-1/4” W x 4-7/8” H
6. Insert Depth: 1-3/4”.
7. Latch Projection: ½” to ¾”.
8. Deadbolt Projection: 1”.s
9. Strength: 1500lbf Static or Greater.
10. Certifications: UL 294 Listed for Access Control Unit Accessory (6th Edition) UL 1034 burglary-resistant Listed UL 10C, 3-hour fire-rating Listed3 CAN/ULC S104, 3-hour fire-rating Listed3 Certified to ANSI/BHMA standard A156.31, Grade 1, endurance 500,000 cycles.
11. Power: 12/24VDC Field-selectable.
12. Warranty: 5 year limited
13. Products: BEST All-in-One Strikes Model# BES-F2164, furnish with Latch Monitor
SAJU 256256 087100 - 6
BEST Model# BES-F2LM or Approved Equal. Substitutions permitted based on product properties and compatibility with existing lock systems.
C. Electric Strike for Rim Exit Device
1. Strike Function: Fail-Secure.
2. Lock Compatibility: Pullman Rim Exit Device.
3. Configuration: Conventional keeper with Latch Monitor.
4. Construction: Stainless Steel.
5. Insert Depth: Surface Mount.
6. Latch Projection: ½” to ¾”.
7. Strength: 1500lbf Static or Greater.
8. Certifications: UL 294 Listed for Access Control Unit Accessory (6th Edition) UL 1034 burglary-resistant Listed UL 10C, 3-hour fire-rating Listed CAN/ULC S104, 3-hour fire-rating Listed.
9. Power: 12/24VDC Field-selectable.
10. Warranty: 5 year limited
11. Products: BEST ¾” Rim Strikes with Latch Monitor Model# BES-0162LM or Approved
Equal. Substitutions permitted based on product properties and compatibility with existing lock systems.
2.07 OPERATING TRIM
A. Standard: BHMA A156.6.
B. Materials: Fabricate from stainless steel, unless otherwise indicated. Trim for installation on custom fabricated wood doors shall match existing look and material to best fit possible.
2.08 CLOSERS
A. Accessibility Requirements: Comply with the following maximum opening-force requirements:
1. Interior, Non-Fire-Rated Hinged Doors: 5 lbf (22.2 N) applied perpendicular to door.
2. Fire Doors: Minimum opening force allowable by authorities having jurisdiction.
B. Door Closers for Means of Egress Doors: Comply with NFPA 101. Door closers shall not require more than 30 lbf (133 N) to set door in motion and not more than 15 lbf (67 N) to open door to minimum required width.
C. Flush Floor Plates: Provide finish cover plates for floor closers unless thresholds are indicated.
Match door hardware finish, unless otherwise indicated.
D. Recessed Floor Plates: Provide recessed floor plates with insert of floor finish material for floor closers unless thresholds are indicated. Provide extended closer spindle to accommodate thickness of floor finish.
E. Size of Units: Unless otherwise indicated, comply with manufacturer's written recommendations for size of door closers depending on size of door, exposure to weather, and anticipated frequency of use. Provide factory-sized closers, adjustable to meet field conditions and requirements for opening force.
F. Surface Closers: BHMA A156.4, Grade 1 unless Grade 2 is indicated. Provide type of arm required for closer to be located on non-public side of door, unless otherwise indicated.
1. Manufacturers:
a. Corbin Russwin Architectural Hardware; an ASSA ABLOY Group company (CR).
b. LCN Closers; an Ingersoll-Rand Company (LCN).
c. SARGENT Manufacturing Company; an ASSA ABLOY Group company (SGT).
d. Yale Commercial Locks and Hardware; an ASSA ABLOY Group company
(YAL).
G. Concealed Closers: BHMA A156.4, Grade 1 unless Grade 2 is indicated.
1. Manufacturers:
a. Corbin Russwin Architectural Hardware; an ASSA ABLOY Group company (CR).
SAJU 256256 087100 - 7
b. LCN Closers; an Ingersoll-Rand Company (LCN).
c. SARGENT Manufacturing Company; an ASSA ABLOY Group company (SGT).
H. Closer Holder Release Devices: BHMA A156.15.
1. Life-Safety Type: On release of hold open, door becomes self-closing. Automatic release is activated by smoke detection system.
2. Manufacturers:
a. Corbin Russwin Architectural Hardware; an ASSA ABLOY Group company (CR).
b. LCN Closers; an Ingersoll-Rand Company (LCN).
c. SARGENT Manufacturing Company; an ASSA ABLOY Group company (SGT).
I. Coordinators: BHMA A156.3.
2.09 PROTECTIVE TRIM UNITS
A. Size: 1-1/2 inches (38 mm) less than door width on push side and 1/2 inch (13 mm) less than door width on pull side, by height specified in door hardware sets.
1. Metal Protective Trim Units: BHMA A156.6; beveled top and 2 sides; fabricated from material indicated in door hardware sets, or the following material: 0.050-inch- (1.3-mm- ) thick stainless steel.
2. Manufacturers:
a. American Floor Products Co., Inc. (AFP).
b. Hager Companies (HAG).
c. Rockwood Manufacturing Company (RM).
d. Trimco (TBM).
B. Plastic Protective Trim Units: BHMA A156.6; beveled 4 sides; fabricated from material indicated in door hardware sets, or the following material:
1. Plastic Laminate: 1/8 inch (3.2 mm) thick; NEMA LD 3, Grade HGS.
2. Rigid Plastic: 0.060-inch- (1.5-mm-) thick, PVC or acrylic-modified vinyl plastic.
3. Acrylic: 1/8 inch (3.2 mm) thick.
4. Color and Texture: As selected by Architect/Engineer from manufacturer's full range.
5. Manufacturers:
a. Balco Inc. (BAL).
b. Hager Companies (HAG).
c. Trimco (TBM).
2.10 STOPS AND HOLDERS
A. Stops and Bumpers: BHMA A156.16, Grade 1 unless Grade 2 is indicated.
1. Provide floor stops for doors unless wall or other type stops are scheduled or indicated.
Do not mount floor stops where they will impede traffic. Where floor or wall stops are not appropriate, provide overhead holders.
B. Mechanical Door Holders: BHMA A156.16, Grade 1 unless Grade 2 is indicated.
C. Combination Floor and Wall Stops and Holders: BHMA A156.8, Grade 1 unless Grade 2 is indicated.
D. Combination Overhead Stops and Holders: BHMA A156.8, Grade 1 unless Grade 2 is indicated.
E. Electromagnetic Door Holders: BHMA A156.15.
F. Silencers for Door Frames: BHMA A156.16, Grade 1; neoprene or rubber; fabricated for drilled-in application to frame.
G. Manufacturers:
1. Baldwin Hardware Corporation (BH).
2. Glynn-Johnson; an Ingersoll-Rand Company (GJ).
3. Hager Companies (HAG).
4. SARGENT Manufacturing Company; an ASSA ABLOY Group company (SGT).
SAJU 256256 087100 - 8
5. Stanley Commercial Hardware; Div. of The Stanley Works (STH).
6. Trimco (TBM).
2.11 DOOR GASKETING
A. Standard: BHMA A156.22.
B. General: Provide continuous weather-strip gasketing on exterior doors and provide smoke, light, or sound gasketing on interior doors where indicated or scheduled. Provide noncorrosive fasteners for exterior applications and elsewhere as indicated.
1. Perimeter Gasketing: Apply to head and jamb, forming seal between door and frame.
2. Meeting Stile Gasketing: Fasten to meeting stiles, forming seal when doors are closed.
3. Door Bottoms: Apply to bottom of door, forming seal with threshold when door is closed.
C. Smoke-Labeled Gasketing: Assemblies complying with NFPA 105 that are listed and labeled by a testing and inspecting agency acceptable to authorities having jurisdiction, for smoke- control ratings indicated, based on testing according to UL 1784.
1. Provide smoke-labeled gasketing on 20-minute-rated doors and on smoke-labeled doors.
D. Sound-Rated Gasketing: Assemblies that are listed and labeled by a testing and inspecting agency, for sound ratings indicated, based on testing according to ASTM E 1408.
E. Replaceable Seal Strips: Provide only those units where resilient or flexible seal strips are easily replaceable and readily available from stocks maintained by manufacturer.
F. Gasketing Materials: ASTM D 2000 and AAMA 701/702.
G. Manufacturers:
1. Hager Companies (HAG).
2. National Guard Products (NGP).
3. Pemko Manufacturing Co. (PEM).
2.12 THRESHOLDS
A. Standard: BHMA A156.21.
B. Accessibility Requirements: Bevel raised thresholds with a slope of not more than 1:2. Provide thresholds not more than 1/4 inch (13 mm) high for exterior doors.
C. Thresholds for Means of Egress Doors: Comply with NFPA 101. Maximum 1/4 inch (13 mm) high.
D. Manufacturers:
1. Hager Companies (HAG).
2. National Guard Products (NGP).
3. Pemko Manufacturing Co. (PEM).
2.13 MISCELLANEOUS DOOR HARDWARE
A. Boxed Power Supplies: Modular unit in NEMA ICS 6, Type 4 enclosure; filtered and regulated;
voltage rating and type matching requirements of door hardware served; and listed and labeled for use with fire alarm systems.
B. Auxiliary Hardware: BHMA A156.16, Grade 1 unless Grade 2 is indicated.
1. Manufacturers:
a. Baldwin Hardware Corporation (BH).
b. Hager Companies (HAG).
c. Stanley Commercial Hardware; Div. of The Stanley Works (STH).
d. Trimco (TBM).
2.14 FABRICATION
A. Base Metals: Produce door hardware units of base metal, fabricated by forming method
SAJU 256256 087100 - 9
indicated, using manufacturer's standard metal alloy, composition, temper, and hardness.
Furnish metals of a quality equal to or greater than that of specified door hardware units and BHMA A156.18. Do not furnish manufacturer's standard materials or forming methods if different from specified standard.
B. Fasteners: Provide screws according to commercially recognized industry standards for application intended, except aluminum fasteners are not permitted. Provide Phillips flat-head screws with finished heads to match surface of door hardware, unless otherwise indicated.
1. Comply with NFPA 80 for fasteners of door hardware in fire-rated applications.
C. Finishes: BHMA A156.18, as indicated in door hardware sets.
PART 3 - EXECUTION
3.01 INSTALLATION
A. Electronic Access Control Systems:
1. Doors that swing outward from “Safe” area require that electric lock or latch be placed at interior on the protected side of door. The following configurations may be utilized to satisfy this requirement:
a. Electric Mortise Exit Device with Standard Strike.
b. Pullman Rim Exit Device with Electric Strike for Rim Exit Device.
c. Electric Mortise Lock with Standard Strike.
2. Doors that swing inward to “Safe” area shall be configured with mechanical Cylindrical or Mortise type locks. A lock specific electric strike shall be installed at door frame, unless specified elsewhere.
B. Steel Doors and Frames: Comply with DHI A115 Series. Drill and tap doors and frames for surface-applied door hardware according to ANSI A250.6.
C. Wood Doors: Comply with DHI A115-W Series.
D. Mounting Heights: Mount door hardware units at heights indicated as follows unless otherwise indicated or required to comply with governing regulations.
1. Standard Steel Doors and Frames: DHI's "Recommended Locations for Architectural
Hardware for Standard Steel Doors and Frames."
2. Custom Steel Doors and Frames: DHI's "Recommended Locations for Builders'
Hardware for Custom Steel Doors and Frames."
3. Wood Doors: DHI WDHS.3, "Recommended Locations for Architectural Hardware for
Wood Flush Doors."
E. Install each door hardware item to comply with manufacturer's written instructions. Where cutting and fitting are required to install door hardware onto or into surfaces that are later to be painted or finished in another way, coordinate removal, storage, and reinstallation of surface protective trim units with finishing work specified in Division 09 Sections. Do not install surface-mounted items until finishes have been completed on substrates involved.
F. Boxed Power Supplies: Locate power supplies as indicated or, if not indicated, in storage room.
Verify location with Architect/Engineer and Owner.
1. Configuration: Provide one power supply for each door opening.
2. Configuration: Provide the least number of power supplies required to adequately serve doors with electrified door hardware.
G. Thresholds: Set thresholds for exterior and acoustical doors in full bed of sealant complying with requirements specified in Division 07 Section "Joint Sealants."
H. Adjustment: Adjust and check each operating item of door hardware and each door to ensure proper operation or function of every unit. Replace units that cannot be adjusted to operate as intended. Adjust door control devices to compensate for final operation of heating and ventilating equipment and to comply with referenced accessibility requirements.
1. Spring Hinges: Adjust to achieve positive latching when door is allowed to close freely
SAJU 256256 087100 - 10
from an open position of 30 degrees.
2. Door Closers: Unless otherwise required by authorities having jurisdiction, adjust sweep period so that, from an open position of 70 degrees, the door will take at least 3 seconds to move to a point 3 inches from the latch, measured to the leading edge of the door.
END OF SECTION 087100
SAJU 256256 323119 - 1
DECORATIVE METAL FENCES AND GATES
SECTION 323119 - DECORATIVE METAL FENCES AND GATES
PART 1 – GENERAL
1.01 SECTION INCLUDES
A. Stainless steel gates
1.02 QUALITY ASSURANCE
A. Manufacturer’s Qualifications: Company specializing in manufacturing products specified in this section with minimum five years documented experience.
B. Source limitations: Obtain system components through one source from a single manufacturer.
Obtain manufacturer’s approval for any products not available through manufacturer.
C. Installer Qualifications: Experienced with type of construction involved and materials and techniques specified and approved by gate manufacturer.
1.03 DELIVERY, STORAGE AND HANDLING
A. Package and store products under cover in manufacturer’s unopened packaging until ready for installation.
B. Store prefinished material off ground and protect from weather. Prevent twisting, bending, or abrasion, and provide ventilation to stored materials.
C. Prevent contact with materials that may cause discoloration of staining of products.
1.04 WARRANTY
A. Correct defective Construction work within a one-year period after the Date of Substantial Completion.
1.05 SUBMITTALS
A. Shop Drawings: Indicate plan layout, spacing of components, post foundation dimensions, hardware anchorage, gates, and schedule of components.
B. Product Data: Submit data on fabric, posts, accessories, fittings and hardware.
C. Manufacturer's Installation Instructions: Submit installation requirements and post foundation anchor bolt templates.
D. Welding certificates.
PART 2 – PRODUCTS
2.01 MANUFACTURERS
A. Manufacturer shall be a qualified technical specialist in the manufacturing of decorative metal and stainless steel gates.
2.02 GATES
A. Materials
1. 316L Marine grade stainless steel.
B. Accessories
SAJU 256256 323119 - 2
DECORATIVE METAL FENCES AND GATES
1. Hardware: Provide manufacturer’s hardware as required unless indicated otherwise.
2.03 FABRICATION
A. Field measurement will be taken prior to fabrication, to ensure proper fitting of the new B. gate.
C. Fabricate and preassemble components in the shop to the greatest extent possible.
D. Mill joints to tight, hairline fit. Accurately fit joints; make joints flush, hairline and weatherproof.
E. Supply components required for anchorage of fabrications. Fabricate anchors and related components of the same material and finish as fabrication, except where specifically noted otherwise.
F. Attach gate to anchors with solid welds. Spot weld are not acceptable. All welds shall be ground to provide uniform smooth surface, blending with adjoining surfaces.
G. Design gates in accordance with the International Building Code.
H. Spacing on gates shall be such that a 4-inch sphere cannot pass through the gate.
PART 3 - EXECUTION
3.01 EXAMINATION
A. Do not begin installation until foundations have been properly installed and prepared.
B. If foundation installation is the responsibility of another installer, notify Contracting Officer of unsatisfactory preparation before proceeding.
3.02 INSTALLATION
A. Install in accordance with manufacturer’s instructions.
B. Install gates level, plumb, and secure for full opening without interference. Attach hardware using tamper-resistant or concealed means. Adjust hardware for smooth operation and lubricate where necessary.
3.03 CLEANING
A. Clean jobsite of excess materials; scatter excess material from installation process.
B. Clean gate with mild household detergent and clean water, rinse well.
C. Touch up scratched surfaces using materials recommended by manufacturer.
3.04 PROTECTION
A. Protect installed products until completion of project.
B. Touch-up, repair, or replace damaged products before Date of Substantial Completion.
END OF SECTION 323119
Gate Entrance to Tunnel at Santa Teresa North (18.46793°N, 66.10974°W) http://maps.google.com/?q=18.46793393749898,-66.10974589438132
Gate Entrance to Tunnel at Santa Teresa East (18.46773°N, 66.10989°W) http://maps.google.com/?q=18.467732319184982,-66.10989810974674
Gate Entrance to Tunnel at Abanico (18.46750°N, 66.10761°W);
http://maps.google.com/?q=18.467500,-66.107610