Attachment 0010e.3 – E092 thru E101 Wkstn Display-FMECA.xlsx

XLSX spreadsheet 40 KB Posted

Attached to
RFP for Integrated Battle Command System (IBCS) LRIP/FRP Federal contract opportunity
Solicitation number
W31P4Q-20-R-0015
Issued by
Department of the Army Materiel Command Contracting Command Redstone Arsenal

About this file

This document contains a Failure Modes and Effects Criticality Analysis (FMECA) for workstation displays that are part of an Integrated Battle Command System (IBCS). The FMECA identifies 40 potential failure modes across 10 displays with probabilities of 0.0000911 for each failure mode. The displays are designated as E092 through E101 and are categorized as Category III failures. The FMECA was conducted for the IBCS Collaborative Environment to support the Army's solicitation for IBCS Low Rate Initial Production/Full Rate Production. The solicitation seeks hardware production of IBCS end items along with associated software and firmware updates, cybersecurity, and authority to operate. Questions regarding the solicitation are due by December 10, 2020 at 4pm Central Standard Time. The opportunity is open only to contractors that met entrance criteria through the SAM portal and were approved by the Integrated Fires Mission Command Project Office. The Department of the Army is the contracting agency.

View the file

Other files for this federal contract opportunity

Other files attached to RFP for Integrated Battle Command System (IBCS) LRIP/FRP, newest first.
File Type Posted
EXHIBIT A - CONTRACT DATA ITEM REQUIREMENTS LIST (CDRL) - 24NOV2020.pdf PDF
Exhibit C- IBCS DSL - 24NOV2020.docx DOCX document
Attachment 0002 - AIAMD System of Systems (SoS)(MIS-PRF-56500).pdf PDF
Attachment 0004b - Relay Acceptance Test Procedures_FINAL.docx DOCX document
Attachment 0004d - Operator Procedures For IFMC GSIL.docx DOCX document
Attachment 0005 - Software Installation Instructions.docx DOCX document
Attachment 0008 - AIAMD IUID Plan Appendix A - IUID Candidates List Data Items.pdf PDF
Attachment 0009 - R and M Prediction Report.docx DOCX document
Attachment 0010a.3 – R003 KG-250X-FMECA.xlsx XLSX spreadsheet
Attachment 0010a.7 – R007 Relay Network Switch-Parvus Switch-FMECA.xlsx XLSX spreadsheet
Attachment 0010a.9 – R015 PDU Assembly-FMECA.xlsx XLSX spreadsheet
Attachment 0010a.13 – R031 Black Router--FMECA.xlsx XLSX spreadsheet
Attachment 0010c.3 – E048 HRFU-FMECA.xlsx XLSX spreadsheet
Attachment 0010c.8 – E053 Shelter Time Server-FMECA.xlsx XLSX spreadsheet
Attachment 0010c.9 – E059 Shelter Switch – 01-FMECA.xlsx XLSX spreadsheet
Attachment 0010d.7 – E153 RS112 Server -06 Shelter with PT-FMECA.xlsx XLSX spreadsheet
Attachment 0010d.8 – E153 RS112 Server -07 Shelter with PT-FMECA.xlsx XLSX spreadsheet
Attachment 0010e.9 – E147 – Table 3 Assembly-FMECA.xlsx XLSX spreadsheet
Attachment 0012 - Risk Management Plan.pdf PDF
Attachment 0013c - IBCS-A301-003 Vol II Instructor Guide_redacted.pdf PDF
Attachment 0013f - D-IBCS-0428-001_Delta_Software_SG_redacted.pdf PDF
Attachment 0013g - D-IBCS-0471_Delta2_Suppl_PE_redacted.pdf PDF
Attachment 0014 RevC - Technical Library.docx DOCX document
Attachment 0016 - Example Cage Code and Cognizant DCMA DCAA Information.xlsx XLSX spreadsheet
Attachment 0022a - CASS to PDRS.docx DOCX document
Attachment 0022a.1.e - ALH-215333 00 S-280 CASS INSTALLA.pdf PDF
Attachment 0022a.1.h - PL-ALH-211130 00 CABLE ASSEMBLY C.pdf PDF
Attachment 0022a.4 - CASS Task Purpose.v2.pptx PPTX presentation
Attachment 0025 - DD254.pdf PDF
Attachment 0010b.6 – E030 KVM Console-FMECA.xlsx XLSX spreadsheet
Attachment 0010a.5 – R005 SCIM-FMECA.xlsx XLSX spreadsheet
Attachment 0013i - D-IBCS-0473_Adv_NetMgr.pdf PDF
W31P4Q-20-R-0015- LRIP FRP - 25NOV2020.pdf PDF
Exhibit B - LRIP FRP TO 0001 DD1423 CDRLs_24NOV2020.pdf PDF
Attachment 0001 - IBCS LRIP FRP Statement of Work - 24NOV2020.docx DOCX document
Attachment 0010a.1 – R001 HRFU-FMECA.xlsx XLSX spreadsheet
Attachment 0010a.2 – R002 BPU-FMECA.xlsx XLSX spreadsheet
Attachment 0010a.6 – R006 TIMING UNIT-FMECA.xlsx XLSX spreadsheet
Attachment 0010a.12 – R030 PFPU SSHD-1—FMECA.xlsx XLSX spreadsheet
Attachment 0010a.14 – R032 Media Converter Module 11-FMECA.xlsx XLSX spreadsheet
Attachment 0010b.1 – E001 28VDC Pwr Supply Shelter Power-FMECA.xlsx XLSX spreadsheet
Attachment 0010b.10 – E034 R112 Shelter – Server Stack – 04-FMECA.xlsx XLSX spreadsheet
Attachment 0010c.6 – E051 IGRM-FMECA.xlsx XLSX spreadsheet
Attachment 0010c.11 – E061 Isolation Router Red-FMECA.xlsx XLSX spreadsheet
Attachment 0010c.12 – E062 Shelter Router-Red-FMECA.xlsx XLSX spreadsheet
Attachment 0010c.16 – E069 Media Converter 03 - FMECA.xlsx XLSX spreadsheet
Attachment 0010d.1 – E123 TMSS – ECU-FMECA.xlsx XLSX spreadsheet
Attachment 0010d.4 – E151 – Media Converter 04-FMECA.xlsx XLSX spreadsheet
Attachment 0010d.6 – E153 RS112 Server -05 Shelter with PT-FMECA.xlsx XLSX spreadsheet
Attachment 0010e.5 – E122 – EMI Tent PDU-FMECA.xlsx XLSX spreadsheet
Show all 50

RFP for Integrated Battle Command System (IBCS) LRIP/FRP has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Pivot Table

W31P4Q-20-R-0015
ATTACHMENT 0010e.3
TAB 1 OF 4
Row LabelsSum of CmCount of Failure Mode Description
Failure to operate at a prescribed time9.11E-0510
Non-normal operation9.11E-0510
Premature operation9.11E-0510
Shorted Input Power9.11E-0510
Grand Total3.64E-0440

Prelim Analysis

W31P4Q-20-R-0015
ATTACHMENT 0010e.3
TAB 2 OF 4
Major End Item:ICBS Colaborative Environment (ICE)
PRELIMINARY ANALYSIS:Parent LRU:E092 thru E101-ICE Workstation Display #1 thru #10
Component:TL-351 20.1" RUGGED DISPLAY
Mission Phase-Operational Mode:All Phases
Cr = ∑Cm =3.64E-04
Failure ModesCount of
Failure ModesSeverity ClassificationsCount of

Seveverity Classification Failure Modes Sum of Cm Count of Failure Modes

Failure to operate at a prescribed time1025.00%Category III40Failure to operate at a prescribed time9.11E-0510
Non-normal operation1025.00%Failure to operate at a prescribed time10Non-normal operation9.11E-0510
Premature operation1025.00%Non-normal operation10Premature operation9.11E-0510
Shorted Input Power1025.00%Premature operation10Shorted Input Power9.11E-0510
Grand Total40Shorted Input Power10Grand Total3.64E-0440
Grand Total40

Cat I and Cat II

W31P4Q-20-R-0015
ATTACHMENT 0010e.3
TAB 3 OF 4
No Category I and Category II Classifications

Data

W31P4Q-20-R-0015
ATTACHMENT 0010e.3
TAB 4 OF 4
Major End Item:ICBS Colaborative Environment (ICE)
Parent LRU:E092 thru E101-ICE Workstation Display #1 thru #10
Component:TL-351 20.1" RUGGED DISPLAY
Mission Phase-Operational Mode:All Phases
FPMH:10.124(20.247)
t:72hr72
Cr = ∑Cm =3.64E-05
Modified Cr =3.64E-05
Due to the k-of-10 Configuration of the ICE (k = 4) a Failure Rate Adjustmust of 50% was performed.
No Category I and Category II Classifications due to the k-of-n configuration of the ICE
Failure Effect atFailure Detection MethodCompensating Provisions
ID#Parent LRUFunctionFailure Mode DescriptionFailure CauseLocal Failure EffectsNext Higher Level Failure EffectsMajor End Item Failure EffectsSafety
ConsiderationSafety
ImpactOperator ObservationVisual IndicatorC-Bit
CapabilitiesSeveverity
ClassificationAlternate Design
ModificationsModified Severity
ClassificationββmodαλPCmMod Cm
3216E092-ICE Display #1Workstation DisplayFailure to operate at a prescribed timeHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-31 (ICE Workstation #1 Power Indicator is OFF)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3217E092-ICE Display #1Workstation DisplayShorted Input PowerHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20N/ATBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3218E092-ICE Display #1Workstation DisplayNon-normal operationHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-41 (ICE Display #1 Relocation Test)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3219E092-ICE Display #1Workstation DisplayPremature operationHardware FailureInadvertent operationPossible loss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-51 (ICE Display #1 Image Problem or Fault Light Indication)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3220E093-ICE Display #2Workstation DisplayFailure to operate at a prescribed timeHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-32 (ICE Workstation #2 Power Indicator is OFF)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3221E093-ICE Display #2Workstation DisplayShorted Input PowerHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20N/ATBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3222E093-ICE Display #2Workstation DisplayNon-normal operationHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-42 (ICE Display #2 Relocation Test)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3223E093-ICE Display #2Workstation DisplayPremature operationHardware FailureInadvertent operationPossible loss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-52 (ICE Display #2 Image Problem or Fault Light Indication)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3224E094-ICE Display #3Workstation DisplayFailure to operate at a prescribed timeHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-33 (ICE Workstation #3 Power Indicator is OFF)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3225E094-ICE Display #3Workstation DisplayShorted Input PowerHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20N/ATBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3226E094-ICE Display #3Workstation DisplayNon-normal operationHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-43 (ICE Display #3 Relocation Test)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3227E094-ICE Display #3Workstation DisplayPremature operationHardware FailureInadvertent operationPossible loss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-53 (ICE Display #3 Image Problem or Fault Light Indication)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3228E095-ICE Display #4Workstation DisplayFailure to operate at a prescribed timeHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-34 (ICE Workstation #4 Power Indicator is OFF)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3229E095-ICE Display #4Workstation DisplayShorted Input PowerHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20N/ATBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3230E095-ICE Display #4Workstation DisplayNon-normal operationHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-44 (ICE Display #4 Relocation Test)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3231E095-ICE Display #4Workstation DisplayPremature operationHardware FailureInadvertent operationPossible loss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-54 (ICE Display #4 Image Problem or Fault Light Indication)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3232E096-ICE Display #5Workstation DisplayFailure to operate at a prescribed timeHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-35 (ICE Workstation #5 Power Indicator is OFF)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3233E096-ICE Display #5Workstation DisplayShorted Input PowerHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20N/ATBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3234E096-ICE Display #5Workstation DisplayNon-normal operationHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-45 (ICE Display #5 Relocation Test)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3235E096-ICE Display #5Workstation DisplayPremature operationHardware FailureInadvertent operationPossible loss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-55 (ICE Display #5 Image Problem or Fault Light Indication)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3236E097-ICE Display #6Workstation DisplayFailure to operate at a prescribed timeHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-36 (ICE Workstation #6 Power Indicator is OFF)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3237E097-ICE Display #6Workstation DisplayShorted Input PowerHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20N/ATBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3238E097-ICE Display #6Workstation DisplayNon-normal operationHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-46 (ICE Display #6 Relocation Test)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3239E097-ICE Display #6Workstation DisplayPremature operationHardware FailureInadvertent operationPossible loss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-56 (ICE Display #6 Image Problem or Fault Light Indication)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3240E098-ICE Display #7Workstation DisplayFailure to operate at a prescribed timeHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-37 (ICE Workstation #7 Power Indicator is OFF)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3241E098-ICE Display #7Workstation DisplayShorted Input PowerHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20N/ATBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3242E098-ICE Display #7Workstation DisplayNon-normal operationHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-47 (ICE Display #7 Relocation Test)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3243E098-ICE Display #7Workstation DisplayPremature operationHardware FailureInadvertent operationPossible loss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-57 (ICE Display #7 Image Problem or Fault Light Indication)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3244E099-ICE Display #8Workstation DisplayFailure to operate at a prescribed timeHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-38 (ICE Workstation #8 Power Indicator is OFF)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3245E099-ICE Display #8Workstation DisplayShorted Input PowerHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20N/ATBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3246E099-ICE Display #8Workstation DisplayNon-normal operationHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-48 (ICE Display #8 Relocation Test)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3247E099-ICE Display #8Workstation DisplayPremature operationHardware FailureInadvertent operationPossible loss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-58 (ICE Display #8 Image Problem or Fault Light Indication)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3248E100-ICE Display #9Workstation DisplayFailure to operate at a prescribed timeHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-39 (ICE Workstation #9 Power Indicator is OFF)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3249E100-ICE Display #9Workstation DisplayShorted Input PowerHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20N/ATBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3250E100-ICE Display #9Workstation DisplayNon-normal operationHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-49 (ICE Display #9 Relocation Test)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3251E100-ICE Display #9Workstation DisplayPremature operationHardware FailureInadvertent operationPossible loss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-59 (ICE Display #9 Image Problem or Fault Light Indication)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3252E101-ICE Display #10Workstation DisplayFailure to operate at a prescribed timeHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-40 (ICE Workstation #10 Power Indicator is OFF)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3253E101-ICE Display #10Workstation DisplayShorted Input PowerHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20N/ATBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3254E101-ICE Display #10Workstation DisplayNon-normal operationHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-50 (ICE Display #10 Relocation Test)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3255E101-ICE Display #10Workstation DisplayPremature operationHardware FailureInadvertent operationPossible loss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-60 (ICE Display #10 Image Problem or Fault Light Indication)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06