Attachment 0007 MO AED REQUIREMENTS DATA REV1.pdf
PDF 8 KB Posted
- Solicitation number
- W58RGZ-22-B-0009
View the file
Other files
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
11/23/2021
M746-02PRID 234PS459-1Part Number
6620-01-128-4462NSN CH-47FSystem
TRANSMITTER, RATENomenclature
YAdequate DMWR Available?
DMWR-55-6620-326DMWR ID
10/15/1990DMWR Date
1DMWR Chg #
YPre-Award Survey Recommended?
NCorrelation Performance Study Required ? YPVA Recommended?
NCritical Safety Item?
There are no emerging airworthiness issues, no issues related to ECPs affecting the CSI status, and no concerns over reliability/durability for the CH-47 Transmitter, Rate at the time of this review.
Special Airworthiness Considerations
DMWR along with the cited 13-qty meos are adequate to support a full M&O program. Per FCDD-AMR-AM, no issue of airworthiness impacting the m&o process.
Other Requirements / Comments
If the item is not a CSI and no adequate DMWR is available, approved sources, if any, are listed by CAGE as follows:
NSpecial Post-Contract Award Requirements?
Special Post-Contract Award Requirements
29 Aug 2021 - FCDD-AMR-AM-Sustainment has verified through the ARISE CIM database on 29 Aug 2021 and the part is Non-CSI and Non-NST. DEM
Other Requirements / Comments (Part II)
The applicable DMWR contains detailed procedures regarding IUID requirements for this component. These procedures can be found in MEO(s) D2112, D2113, D2114.
Other Requirements / Comments (Part III)
21 Sept 2021 - FCDD-AMR-MS has re-verified through the ARISE CIM database on 21 Sept 2021 and the part is Non-CSI and Non-NST. DEM
Other Requirements / Comments (Part IV)
Other Requirements / Comments (Part V)
NDoes QE-STD-2 Apply?
N
Additional CSI Requirements
CSI Contains CSI Replacement Parts? NEngineering Testing Required?
Identify Any Special Processes, Test Procedures, and/or Instructions per DMWR requirement
RStatus
YTDPL?
Approved Date
M&O AED REQUIREMENTS DATA
Correlation Performance Study Requirements
Commerciality Determination
Commercial Item? N NBest Commercial Practice Acceptable?
11/23/2021
M746-02PRID 234PS459-1Part Number
6620-01-128-4462NSN CH-47FSystem
C1343
C1351A
C3189A
C4598
C5833
C6572
C6984
C7002
C7160
D2112
D2113
D2114
T1356D per DMWR requirement
Critical Tools and Test and Inspection Equipment Requiring AED Approval for Substitutes
MEOs Required for Competitive Contract?
RStatus
File details come from the government source that posted it. Updated .