Attachment 0006 - 2024-3910 - SOW - Appendix E - Structural Calculations.pdf

PDF 7 MB Posted

Attached to
Quarters 1 - Southwest Patio Repair
Solicitation number
W519TC-25-R-A009
Issued by

About this file

This document is a Structural Calculations Appendix (Appendix E) for the Quarters 1 Southwest Patio Repair project at Rock Island Arsenal. The detailed technical document provides comprehensive structural engineering calculations and design specifications for a comprehensive patio repair and renovation, including deck repair, beam reinforcement, and retaining wall construction. Key design objectives include creating a composite concrete deck with a specific slope, designing built-up section deck beams utilizing existing deck beams, designing a CMU lintel for a new entrance, designing entranceway beams to support the new sloped deck, and designing both basement and ramp retaining walls.

The structural calculations cover multiple design aspects with rigorous engineering analysis, including load combinations, material properties, concrete and steel specifications, and detailed reinforcement requirements. The project involves complex structural modifications, such as welding built-up tee sections to existing W8x18 beams, incorporating concrete incasement, and designing retaining walls with varying base widths and stem heights. The calculations demonstrate compliance with multiple engineering standards including AISC Steel Construction Manual, ACI Concrete Standards, Building Code Requirements, and International Building Code (IBC 2021), with comprehensive checks for structural capacity, shear resistance, bending moments, and reinforcement adequacy across different wall and deck configurations.

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Project Title: ROCK ISLAND ARSENAL

Computation Title: QUARTER 1 PATIO REPAIR

Filename:

Computed by: D. SOLANO Computed on:

Last Saved:

Checked by: [F. LAST] Checked on:

01/24/2025

Q1 Deck Repair.mctx

QUARTERS 1 PATIO REPAIR

Objective:

• Design composite concrete Deck

• Design built-up section utilizing existing deck beams to account for deck slope

• Design CMU lentil for new CMU Entrance

• Design entranceway beams to support new slope deck

• Design entranceway retaining wall

• Design ramp retaining wall

Criteria:

The decking will have an additional slope and be of uniform depth, requiring support beams to maintain the required angle. Built-up Tee with varying depth will be welded to the center of the existing W8x18 to account for slope. The horizontal oriented deck beams near entryway to basement will be flipped to match the orientation of the built-up beams.

Additionally, entryway deck beams will be incased in concrete. Entryway CMU lentil will be design to support the wall in addition to the deck and it's associated loads.

References:

• AISC, Steel Construction Manual 15th Ed.

• ACI Standard, Building Code Requirements for Structural Concrete (ACI 318-19)

• Building Code Requirements and Specification for Masonry Structures (TMS 402/602)

• Minimum Design Loads and Associated Criteria for Buildings and Other Structures (ASCE/SEI 7-22)

• International Building Code (IBC 2021)

App en dix E

Filename:

Computed by: D. SOLANO Computed on:

Last Saved:

Checked by: [F. LAST] Checked on:

01/24/2025

Q1 Deck Repair.mctx

Drawings

App en

GENERAL NOTES

1. THE CONTRACTOR IS RESPONSIBLE FOR DESIGNING, FURNISHING, PLACING AND MAINTAINING ALL TEMPORARY

SUPPORT, BRACING, FORMWORK, AND OTHER SUPPORTS REQUIRED BY WORK.

2. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN ALL NECESSARY SAFEGUARDS TO PROTECT PUBLIC SAFETY AND

ADJOINING PROPERTIES.

3. THE CONTRACTOR SHALL COMPLY WITH ALL FEDERAL, STATE, COUNTY AND MUNICIPAL LAWS, ORDINANCES AND

REGULATIONS.

CONCRETE NOTES

1. ALL DECK CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 4500 PSI, REFER TO SPECIFICATION 03 30 00.

2. ALL CONCRETE GROUT TO HAVE A MINIMUM COMPRESSIVE STRENGTH OF

2000 PSI, REFER TO SPECIFICATION 03 30 00.

STEEL NOTES

1. ALL STRUCTURAL W-SECTION STEEL IS A992, UNLESS NOTED OTHERWISE.

ALL STRUCTURAL ANGLE STEEL IS A36, UNLESS NOTED OTHERWISE.

ALL REBAR STEEL IS A615, UNLESS NOTED OTHERWISE.

2. REMOVE DETERIORATED STEEL STRUCTURE ABOVE AFTER THE PATIO SLAB AND STEEL DECKING HAS BEEN

REMOVED.

3. ALL STRUCTURAL STEEL TO BE PAINTED, ONLY EXCEPTION ARE SURFACES OF STEEL COVER BY CONCRETE EITHER

FROM EMBEDMENT OR ENCASEMENT.

4. ALL WELDING SHALL BE IN ACCORDANCE WITH AWS D1.1. WORKMANSHIP AND TECHNIQUE SHALL CONFORM TO THE AMERICAN WELDING SOCIETY STRUCTURAL WELDING CODES. WELD PROCEDURES SPECIFICATIONS (WPS), PROCEDURE QUALIFICATION RECORDS (PQR) AND WELDING PERFORMANCE QUALIFICATIONS RECORDS (WPQR) SHALL BE IN ACCORDANCE WITH SPECIFICATION SECTION 05 50 14 BEFORE WELDING COMMENCES. SEE

SPECIFICATIONS.

5. WELDING SYMBOLS SHOWN ARE THOSE ADOPTED BY THE AMERICAN WELDING SOCIETY AND INDICATE ONLY SIZE

AND TYPE OF WELD REQUIRED.

E1 S-303

A4 S-301

E1 S-301

E1 S-302

A1 S-301

3'=1'-0"

PLAN VIEWA1

6'-0"5'-0"5'-0"5'-0"6'-0"4'-10"5'-8"5'-6"

W8X10 CONCRETE INCASED DECK BEAMS BUILT-UP VARIABLE DEPTH DECK BEAMS

BASEMENT STAIRS

1'-0"

2'-0"

2'- 9"

4'- 3"

4'- 3"

4'- 3"

3'-0"

1'- 8"

3'- 21 2"

5'-8"

6'- 91 2"

7'- 31 2"

28'-0"

5'-4"23'-8"

6'- 0"

'-0

5'-9"

38'-3"

26'-0"

1'-8"1'-8"

1'- 8"

EXISTING

INTERIOR WALL

BASEMENT

ENTRY

SUSPENDED DECKBASEMENT RETAINING WALL

CANTILEVER RETAINING WALL (TYP)

BASEMENT RETAINING

WALL FOOTING

BASEMENT RETAINING

WALL FOOTING

BASEMENT

RETAINING WALL

CANTILEVER RETAINING WALL FOOTING (TYP)

CANTILEVER RETAINING WALL

CANTILEVER RETAINING

WALL FOOTING

D

AT

E

AP

PR

M

AR

K D

ES

C

R

IP

TI

O

N

SU

BM

IT

TE

D B

Y:

IS

SU

E D

AT

E:

PR

O

JE

C

T N

O

D R

AW

IN

G N

O

U .S

. A R

M Y

G

AR

R

IS

O N

R

O C

K

IS

LA

N

D A

R

SE

N

AL

D

IR

EC

TO

R

AT

E O

F

PU

BL

IC

W O

R

KS

R O

C K

IS

LA

N D

, I L

9-

-3

XX

X-

XX

X

1/

/2

D

ES

IG

N

ED

B Y:

D . S

O

LA

N O

D R

AW

N

B Y:

D . S

O

LA

N O

AP

PR

O

VE

D B

Y:

G

. K O

SK

I, D

IR

EC

TO

R O

F

PU

BL

IC

W O

R

KS

S.

B

AC

H

, C H

IE

F

O F

EN

G

IN

EE

R

IN

G

R O

C K

IS

LA

N D

A R

SE

N

AL

Q

U

AR

TE

R

S

(B U

IL

D

IN

G

SO

U

TH

W

ES

T

PA

TI

O

R

EP

AI

R

A

B

C

D

E

F

G

C H

EC

KE

D B

Y:

H

D O

PRELIMINARY2

EXISTING

EXTERIOR WALL

S-101

PL

AN

V

IE

W

App en

BUILT-UP TEE SECTION

EXISTING WALLEXISTING W8X18

* 3 12" THICK COMPOSITE DECK SHALL BE ALLOWED TO

CURE FOR A MINIMUM OF 7 DAYS PRIOR TO ADDING

TOPPING CONCRETE.

** FIELD CUT 3 8" FROM BOTTOM OF BUILT-UP TEE WEB

STARTING FROM END OF THE EXISTING W8X18 TO END OF

BUILT-UP TEE. ADD AND CENTER A 51

4"X3

8" BEARING PLATE

ALONG THE CUT LENGTH. WELD BEARING PLATE TO

BUILT-UP TEE.

5'=1'-0"

EXTERIOR WALL DECKING SUPPORT DETAILA1

31 2"

VA

RI

ES

L4X3X1

4 END BRACING

TOPPING CONCRETE *

WATERPROOFING MEMBRANE

COMPOSITE SLAB *

2VLI DECK-36-20GAGE

#3 @ 12" C/C

TYP

4"X3

8" BEARING PLATE**

21 2"

8" THICK LINTEL

OVER WINDOW

FIELD

DIMENSION

4"X2" CONCRETE

STUDS @ 12" C/C

A6 S-301

A9 S-301

DECK SLOPE AT 1:64

3/4"=1'-0"

PATIO DECK ELEVATIONE1

END BUILT-UP TEE

AT FACE OF WALL

EXISTING W8X18 DECK BEAM

EXISTING INTERIOR WALLS EXISTING EXTERIOR STONE WALLS

COMPOSITE DECK W/

WATERPROOFING MEMBRANE

GROUT AFTER BUILT-UP TEE

INSTALLATION

TOPPING CONCRETE * A1

S-301

5'=1'-0"

DECK BEAM END SECTION OVER EXTERIOR WALLA6

BUILT-UP

TEE TO

EXISTING BEAM

W8X18

BUILT-UP TEE

L4X3X1

4 END BRACING

TYP

4"X3

8" BEARING

PLATE**

5'=1'-0"

DECK BEAM SECTION OVER INTERIOR WALLA9

BUILT-UP TEE

GROUT AFTER BUILT-UP TEE

INSTALLATION

INTERIOR WALL

W8X18

D

AT

E

AP

PR

M

AR

K D

ES

C

R

IP

TI

O

N

SU

BM

IT

TE

D B

Y:

IS

SU

E D

AT

E:

PR

O

JE

C

T N

O

D R

AW

IN

G N

O

U .S

. A R

M Y

G

AR

R

IS

O N

R

O C

K

IS

LA

N

D A

R

SE

N

AL

D

IR

EC

TO

R

AT

E O

F

PU

BL

IC

W O

R

KS

R O

C K

IS

LA

N D

, I L

9-

-3

XX

X-

XX

X

1/

/2

D

ES

IG

N

ED

B Y:

D . S

O

LA

N O

D R

AW

N

B Y:

D . S

O

LA

N O

AP

PR

O

VE

D B

Y:

G

. K O

SK

I, D

IR

EC

TO

R O

F

PU

BL

IC

W O

R

KS

S.

B

AC

H

, C H

IE

F

O F

EN

G

IN

EE

R

C K

IS

LA

N D

A R

SE

N

AL

Q

U

AR

TE

R

S

(B U

IL

D

IN

G

SO

U

TH

W

ES

T

PA

TI

O

R

EP

AI

R

A

B

C

D

E

F

G

C H

EC

KE

D B

Y:

H

D O

PRELIMINARY2

S-301

ST

R

U C

TU

R

AL

D

ET

AI

LS

App en

5'=1'-0"

INCASED DECK BEAM WALL POCKETA1

31 2"

1"1"

1"

WATERPROOFING MEMBRANE

TOPPING CONCRETE

W8X10

2VLI DECK-36-20GAGE

EXISTING STONE WALL

DRY PACK GROUT

CAST-IN-PLACE

CEMENT GROUT

A8 S-302

1"=10'-0"

BASEMENT ENTRY DOORA4

4" MIN.

1 4"

GA

P

BE

TW

EE

N

CM

U W

AL

L A

ND

IN

CA

SE

D

DE

CK

B

EA

M

2" CL

R.

1'-0"

1'- 0"

INCASED W8X10 DECK BEAM

#4 STRAIGHT BAR

W/ #3 HOOKED BARS

#4 STRAIGHT BAR

2"

4'=1'-0"

BASEMENT WALL REINFORCMENTA8

2" CL

R.

8"

4"

2-#4

2-#4

A1 S-302

BEAM SLOPE AT 1:64

6'=1'-0"

BASEMENT ENTRY PATIO DECK ELEVATION E1

4"

1" ALL AROUND (TYP)

4"

TYP MINIMUM

BEARING LENGTH

INTO STONE WALL

INCASED W8X10 DECK

BEAM

WALL POCKET

DRY PACK GROUT

CAST-IN-PLACE

CEMENT GROUT

WATERPROOFING MEMBRANE

(SEE ARCHITECTURAL DRAWINGS)

SET AND SHORE DECKING BEAMS IN PLACE PRIOR

TO CASTING CONCRETE WALL

NEW CONCRETE WALL

EXISTING WALL

LIMESTONE VENEER (TYP)

(SEE ARCHITECTURAL DRAWINGS

D

AT

E

AP

PR

M

AR

K D

ES

C

R

IP

TI

O

N

SU

BM

IT

TE

D B

Y:

IS

SU

E D

AT

E:

PR

O

JE

C

T N

O

D R

AW

IN

G N

O

U .S

. A R

M Y

G

AR

R

IS

O N

R

O C

K

IS

LA

N

D A

R

SE

N

AL

D

IR

EC

TO

R

AT

E O

F

PU

BL

IC

W O

R

KS

R O

C K

IS

LA

N D

, I L

9-

-3

XX

X-

XX

X

1/

/2

D

ES

IG

N

ED

B Y:

D . S

O

LA

N O

D R

AW

N

B Y:

D . S

O

LA

N O

AP

PR

O

VE

D B

Y:

G

. K O

SK

I, D

IR

EC

TO

R O

F

PU

BL

IC

W O

R

KS

S.

B

AC

H

, C H

IE

F

O F

EN

G

IN

EE

R

C K

IS

LA

N D

A R

SE

N

AL

Q

U

AR

TE

R

S

(B U

IL

D

IN

G

SO

U

TH

W

ES

T

PA

TI

O

R

EP

AI

R

A

B

C

D

E

F

G

C H

EC

KE

D B

Y:

H

D O

PRELIMINARY2

S-302

ST

R

U C

TU

R

AL

D

ET

AI

LS

App en

C7 S-303

*** DECK SLAB SHALL BE CAST AND CURED PRIOR TO

BACKFILLING BEHIND BASEMENT RETAINING WALL.

1/2"=1'-0"

ENTRY STAIR - SECTIONE1

A3 S-303

A3 S-303

A1 S-303

EXISTING WALL

INCASE DECK BEAM

COMPACTED AGGREGATE (TYP)

SUSPENDED SLAB***DECK SLAB

RAMP SLAB

***DECK SLAB

LIMESTONE VENEER (TYP)

(SEE ARCHITECTURAL DRAWINGS)

6'=1'-0"

BASEMENT RETAINING WALL DETAILSA1

BEDROCK

COMPACTED

SOIL

COMPACTED

AGGREGATE

11 2"

CL

EA

R

CO

VE

R (T

YP

8"

1'- 0"

6"

2"

CLR.

3" CL

R.

2" CL

R.

2"

#4 S

PA

" O

.C

2"

6"

1'-8"

#5 SPA. @ 6" C/C

#5 @ 6" C/C

SUSPENDED SLABDECK SLAB

EL. ±88'-0"

TOP OF

FOOTING

EL. ±87'-0"

6-#4 @ 6" C/C

BASE TRANSVERSE

REINFORCEMENT

1-1/2"=1'-0"

CANTILEVER RETAINING WALL DETAILSA3

COMPACTED SOIL

COMPACTED

AGGREGATE

**** FILL COVER SOIL DEPTH ON

BOTH SIDE OF CANTILEVER

RETAINING WALLS PRIOR TO

FILLING RETAINING DEPTH.

11 2"

CL

EA

R

CO

VE

R (T

YP

6"

1'- 0"

6"

3" CL

R.

2" CL

R.

2"

CLR.

2"

3'- 6"

* C

OV

ER

D

EP

TH

VA

RI

ES

RE

TA

IN

IN

G

DE

PT

H

#4

" C

/C

VARIES

(SEE PLAN VIEW FOR FOOTING WIDTH)

4"

#4 @ 12" C/C

BASE TRANSVERSE

REINFORCEMENT

( QUANTITY OF BARS

BASED ON WIDTH

OF BASE)

#5 @ 12" C/C

RAMP SLAB

COMPACTED

AGGREGATE

TYP.

#5 SPA. @ 6" C/C

A7 S-303

3"=1'-0"

SUSPENDED SLAB REINFORCEMENTC7

3"

6"

6'-0"

3"

7-#5 STRAIGHT BARS @ 12" C/C

6'-10"

SUSPENDED SLAB

2'- 0"

M

IN

2'-0" MIN. SPLICE

2'-0" MIN. SPLICE

1-1/2"=1'-0"

SUSPENDED SLAB REINFORCEMENT - SECTIONA7

2'- 0"

M

IN

PATIO RAMP

RETAINING WALL

BASEMENT

RETAINING WALL

#5 @ 12"

SUSPENDED SLAB

COMPOSITE

SLAB

CANTILEVER

RETAINING WALL

REINFORCEMENT

TYP.

#5 BENT

BAR @ 12"

#5 BENT BAR @ 12"

BASEMENT

RETAINING WALL

REINFORCEMENT

TYP.

D

AT

E

AP

PR

M

AR

K D

ES

C

R

IP

TI

O

N

SU

BM

IT

TE

D B

Y:

IS

SU

E D

AT

E:

PR

O

JE

C

T N

O

D R

AW

IN

G N

O

U .S

. A R

M Y

G

AR

R

IS

O N

R

O C

K

IS

LA

N

D A

R

SE

N

AL

D

IR

EC

TO

R

AT

E O

F

PU

BL

IC

W O

R

KS

R O

C K

IS

LA

N D

, I L

9-

-3

XX

X-

XX

X

1/

/2

D

ES

IG

N

ED

B Y:

D . S

O

LA

N O

D R

AW

N

B Y:

D . S

O

LA

N O

AP

PR

O

VE

D B

Y:

G

. K O

SK

I, D

IR

EC

TO

R O

F

PU

BL

IC

W O

R

KS

S.

B

AC

H

, C H

IE

F

O F

EN

G

IN

EE

R

C K

IS

LA

N D

A R

SE

N

AL

Q

U

AR

TE

R

S

(B U

IL

D

IN

G

SO

U

TH

W

ES

T

PA

TI

O

R

EP

AI

R

A

B

C

D

E

F

G

C H

EC

KE

D B

Y:

H

D O

PRELIMINARY2

S-303

ST

R

U C

TU

R

AL

D

ET

AI

LS

App en

C9 S-501

6"=1'-0"

BUILT-UP TEE BEAM ( 6 TOTAL)C1 6"=1'-0"

BUILT-UP TEE BEAM - SECTIONC9

61 4"

27'-2"

13 16

VA

RI

ES

MI

N 13 16

MA

X 61 4""

4"

3 8"

4"

3 8"

3 8"

4"3 8"

FIELD DIMENSION

TYP

4"⅊

BEARING

PLATE

BEARING PLATE

TYP

A9 S-501

1'=5'-0"

W8X10 DECK BEAM (3 TOTAL)A1 1'=5'-0"

W8X10 DECK BEAMS - SECTIONA9

8'-6"

W8X10

W8X10

E9 S-501

5'=1'-0"

BUILT-UP DECK BEAMS END BRACING ANGLE (1 TOTAL)E1 5'=1'-0"

END BRACING ANGLE - SECTIONE9

28'-8"

L4X3X1

L4X3X1

D

AT

E

AP

PR

M

AR

K D

ES

C

R

IP

TI

O

N

SU

BM

IT

TE

D B

Y:

IS

SU

E D

AT

E:

PR

O

JE

C

T N

O

D R

AW

IN

G N

O

U .S

. A R

M Y

G

AR

R

IS

O N

R

O C

K

IS

LA

N

D A

R

SE

N

AL

D

IR

EC

TO

R

AT

E O

F

PU

BL

IC

W O

R

KS

R O

C K

IS

LA

N D

, I L

9-

-3

XX

X-

XX

X

1/

/2

D

ES

IG

N

ED

B Y:

D . S

O

LA

N O

D R

AW

N

B Y:

D . S

O

LA

N O

AP

PR

O

VE

D B

Y:

G

. K O

SK

I, D

IR

EC

TO

R O

F

PU

BL

IC

W O

R

KS

S.

B

AC

H

, C H

IE

F

O F

EN

G

IN

EE

R

C K

IS

LA

N D

A R

SE

N

AL

Q

U

AR

TE

R

S

(B U

IL

D

IN

G

SO

U

TH

W

ES

T

PA

TI

O

R

EP

AI

R

A

B

C

D

E

F

G

C H

EC

KE

D B

Y:

H

D O

PRELIMINARY2

S-501

ST

R

U C

TU

R

AL

D

ET

AI

LS

App en

Filename:

Computed by: D. SOLANO

Computed on:

Last Saved:

Checked by: H. OCON

Checked on: 1/24/2025

01/24/2025

Q1 Deck Repair.mctx

Analysis and Design

App en

Filename:

Computed by: D. SOLANO

Computed on:

Last Saved:

Checked by: H. OCON

Checked on: 1/24/2025

01/24/2025

Q1 Deck Repair.mctx

Constants and Material Properties:

≔fc 4.0 ksi Concrete Compressive Strength

≔fy_re 60 ksi Rebar Yield Strength

≔fy 60 ksi Steel Yield Strength

≔E 29000 ksi Steel Elastic Modules

≔Dc 150 pcf Density of Concrete

≔Ds 490 pcf Density of Steel

≔εcu .003 Concrete Crushing Strain

≔εs .0075 Steel Strain for Sizing and Tension

Control requirements

Loads

≔LiveLoad 100 psf Live Load (ASCE 7 Table 4.3-1)

≔SnowLoad 20.8 psf Snow Load (See Appendix A)

≔DeckLoad 61.4 psf Deck Weight Per Foot of Width

LRFD Load Combinations:

=LC1 ⋅1.4 D Load Case 1

=LC2 ++⋅1.2 D ⋅1.6 L ⋅0.5 S Load Case 2

=LC3 ++⋅1.2 D ⋅1.0 L ⋅1.6 S Load Case 3

App en

Filename:

Computed by: D. SOLANO

Computed on:

Last Saved:

Checked by: H. OCON

Checked on: 1/24/2025

01/24/2025

Q1 Deck Repair.mctx

Composite Deck The concrete deck is split by a waterproofing membrane into a lower composite slab and a upper topping concrete. Only the the depth of the composite slab was used for calculating one-way slab bending and shear capacities. Required bending and shear stress where calculated using ENERCAL and checked against capacity from VULCRAFT Composite Deck-Slab Tool.

Geometry:

≔DeckSpan 6 ft Deck Max Span

Load Cases:

Loads are based on a unit tributary width

≔L =⋅LiveLoad 1 ft 100 plf Live Load

≔S =⋅SnowLoad 1 ft 20.8 plf Snow Load

≔D =⋅DeckLoad 1 ft 61.4 plf Dead Load

LRFD Load Combinations:

≔LC1 =⋅1.4 D 0.09 klf Load Case 1

≔LC2 =++⋅1.2 D ⋅1.6 L ⋅0.5 S 0.24 klf Load Case 2

≔LC3 =++⋅1.2 D ⋅1.0 L ⋅1.6 S 0.21 klf Load Case 3

≔LCgov =max (( ,,LC1 LC2 LC3)) 0.24408 klf Governing Load Case

App en

Filename:

Computed by: D. SOLANO

Computed on:

Last Saved:

Checked by: H. OCON

Checked on: 1/24/2025

01/24/2025

Q1 Deck Repair.mctx

ENERCALC:

General Beam analysis was used to determine the maximum bending and axial forces on a 1ft width section. The slab was supported at each beam and subjected to ASCE 7-16 load combinations, including snow, live, and dead loads Automatic unbalanced live load placement was used. ENERCALC forces will be used to check against VULCRAFT calculated capacities including deflection limits.(See Appendix B for full ENERCALC print out)

≔Mu_pos ⋅0.846 kip ― ft ft Maximum Positive Bending per Foot of

Slab

(ENERCALC)

≔Mu_neg ⋅-0.846 kip ― ft ft Maximum Negative Bending per Foot of Slab

(ENERCALC)

≔Vu 0.873 ―― kip ft Maximum Shear per Foot of Slab

(ENERCALC)

App en

Filename:

Computed by: D. SOLANO

Computed on:

Last Saved:

Checked by: H. OCON

Checked on: 1/24/2025

01/24/2025

Q1 Deck Repair.mctx

VULCRAFT Composite Deck-Slab Tool :

Capacity of Deck was extracted from VULCRAFT Composite Deck and compared to the beam results from ENERCALC.

Bending, Shear, and deflection limits where checked for congruences against required capacities. (See Appendix C for full

VULCRAFT print out). Additionally, VULCRAFT checks for maximum allowable span prior to composite action.

≔ϕMn_pos ⋅2.77 kip ― ft ft Positive Bending Capacity per Foot of

Slab (VULCRAFT Tool)

≔ϕMn_neg ⋅1.1 kip ― ft ft Negative Bending Capacity per Foot of

Slab (VULCRAFT Tool)

≔ϕVn 3.26 ―― kip ft Shear Capacity per Foot of Slab

(VULCRAFT Tool)

≔Spanmax +6 ft 3 in Maximum Unshored Span for a 22 gage 1.5VL-36 Steel Deck Prior to

Composite Action

=if ⎛⎝ ,,>ϕMn_pos Mu_pos “GOOD” “NG”⎞⎠ “GOOD” Positive Bending Check

=if ⎛⎝ ,,>ϕMn_neg Mu_neg “GOOD” “NG”⎞⎠ “GOOD” Negative Bending Check

=if ⎛⎝ ,,>ϕVn Vu “GOOD” “NG”⎞⎠ “GOOD” Shear Check

=if ⎛⎝ ,,>Spanmax DeckSpan “GOOD” “NG”⎞⎠ “GOOD” Steel Deck Allowable Span Check

App en

Filename:

Computed by: D. SOLANO

Computed on:

Last Saved:

Checked by: H. OCON

Checked on: 1/24/2025

01/24/2025

Q1 Deck Repair.mctx

Built-Up Deck Beam The deck beams will have an additional built-up tee section welded along the top center of the upper flange of the existing

W8x18. The built-up tee will be composed of a 1/2" thick web plate with variable height along its length and a 3/8"x5-1/2" flange plate. Conservatively the beam was checked only using the built-up beam depth at center span of exterior and interior wall. Weld design is based on the section the produces the maximum shear flow. STADD Model was created to calculate the bending and shear forces.

Geometry:

Conservatively set built-up tee flange size to match existing W8x18.

≔Trib_Beam 5.5 ft Deck Max Tributary Width

≔d =+8.14 in 2.86 in 11 in Depth of Beam

≔tw 0.23 in Beam Web Thickness

≔bf 5.25 in Beam Flange Width

≔tf 0.33 in Beam Flange Thickness

≔A 5.9205 in

Area of Beam

≔Ixx 121.9 in

Moment of Inertia About the X axis

≔Iyy 7.97 in

Moment of Inertia About the Y axis

≔Zx 25.02 in

Plastic Section Modules

≔Sx 22.15 in

Elastic Section Modules

≔ry 1.16 in Radii of Gyration

≔Cw 225.27 in

Warping Constant

≔Lb 216 in Unbraced Length

≔J 0.183 in

Torsional Constant

App en

Filename:

Computed by: D. SOLANO

Computed on:

Last Saved:

Checked by: H. OCON

Checked on: 1/24/2025

01/24/2025

Q1 Deck Repair.mctx

Load Cases:

≔DLW18x18 18 plf W8x18 Self-Weight

≔DLTee 12.5 plf Built-Up Tee Self-Weight

≔DLdeck =⋅DeckLoad Trib_Beam 337.7 plf Decking

≔L =⋅LiveLoad Trib_Beam 550 plf Live Load

≔S =⋅SnowLoad Trib_Beam 114.4 plf Snow Load

≔D =++DLdeck DLW18x18 DLTee 368.2 plf Dead Load

LRFD Load Combinations:

≔LC1 =⋅1.4 D 0.52 klf Load Case 1

≔LC2 =++⋅1.2 D ⋅1.6 L ⋅0.5 S 1.38 klf Load Case 2

≔LC3 =++⋅1.2 D ⋅1.0 L ⋅1.6 S 1.17 klf Load Case 3

≔LCgov =max (( ,,LC1 LC2 LC3)) 1.37904 klf Governing Load Case

App en

Filename:

Computed by: D. SOLANO

Computed on:

Last Saved:

Checked by: H. OCON

Checked on: 1/24/2025

01/24/2025

Q1 Deck Repair.mctx

STAAD Model

All boundary conditions are vertical compression only springs.

≔Mu ⋅41.032 kip ft Maximum Bending

(STAAD)

≔MA ⋅-31.628 kip ft Bending at First Quarter of Span 1

(STAAD)

≔MB ⋅-35.333 kip ft Bending at Mid Span of Span 1

(STAAD)

≔MC ⋅-11.112 kip ft Bending at Third Quarter of Span 1

(STAAD)

≔Vu -14.692 kip Maximum Shear

(STAAD)

≔Cb =―――――――――――――――― ⋅12.5 abs ⎛⎝Mu

+++⋅2.5 abs ⎛⎝Mu

⎞⎠ ⋅3 abs ⎛⎝MA ⎞⎠ ⋅4 abs ⎛⎝MB

⎞⎠ ⋅3 abs ⎛⎝MC

1.38 LTB Modification Factor

Section Slenderness (AISC F1)

≔h =-d ⋅2 tf 10.34 in

=if h tw ⋅3.76

E fy

“C” if h tw ⋅5.7

E fy

“S” “NC”

“C”

=if

⋅bf .5 tf ⋅.38

E fy

“C” if

⋅bf .5 tf ⋅1 fy “S” “NC”

“C”

App en

Filename:

Computed by: D. SOLANO

Computed on:

Last Saved:

Checked by: H. OCON

Checked on: 1/24/2025

01/24/2025

Q1 Deck Repair.mctx

Flexural Check (AISC F2)

≔ϕ 0.9

Yielding

≔Mn_yield =⋅fy Zx 125.1 ⋅kip ft

Lateral-Torsional Buckling

≔rts =

‾‾‾‾‾⋅Iyy Cw

Sx

1.38 in

≔c 1

≔ho =-d ― tf

10.84 in

≔Lp =⋅⋅1.76 ry

E fy

44.88 in

≔Lr =⋅⋅⋅1.95 rts ―― E

⋅0.7 fy

⋅J c

⋅Sx ho

⋅J c

⋅Sx ho

⋅6.76

⋅0.7 fy

E

126.36 in

≔Fcr =⋅――― ⋅⋅Cb π

E

Lb rts

+1 ⋅⋅0.078 ――

⋅J c

⋅Sx ho

Lb rts

25.32 ksi

≔ϕMLTB =⋅if else if else

≤Lb Lp

‖ Mn_yield

>Lb Lr

‖ ⋅Fcr Sx

⋅Cb

-Mn_yield ⋅⎛⎝ -Mn_yield ⋅⋅0.7 fy Sx

-Lb Lp

-Lr Lp

.9 42.06 ⋅kip ft

=if ⎛⎝ ,,>min ⎛⎝ ,ϕMLTB Mn_yield ⎞⎠ abs ⎛⎝Mu

⎞⎠ “GOOD” “NG”⎞⎠ “GOOD” Bending Check

Mu ϕMLTB

0.98 Unity Ratio

App en

Filename:

Computed by: D. SOLANO

Computed on:

Last Saved:

Checked by: H. OCON

Checked on: 1/24/2025

01/24/2025

Q1 Deck Repair.mctx

Shear Check (AISC G2)

≔ϕv 0.9

≔h =-d ⋅2 tw 10.54 in

≔kv 5.34

≔Cv1 =if else h tw ⋅1.1

⋅kv ― E fy ‖ 1

⋅1.1

⋅kv ― E fy h tw

≔ϕVn =⋅⋅⋅⋅ϕv 0.6 fy d tw 81.97 kip

=if ⎛⎝ ,,>ϕVn abs ⎛⎝Vu⎞⎠ “GOOD” “NG”⎞⎠ “GOOD” Shear Check abs ⎛⎝Vu⎞⎠ ϕVn

0.18 Unity Ratio

Weld Check

≔dmin =+8.14 in 2.12 in 10.26 in Minimum Section Depth

≔ATop_flange =⋅tf bf 1.73 in

Area of Top Flange

≔yc_top_flange =― tf

0.17 in Centroid of Top Flange

≔Imin =-――― ⋅dmin bf

⋅⎛⎝ -dmin ⋅2 tf⎞⎠ 3 ⎛⎝ -bf tw⎞⎠

102.41 in

Moment of Inertia about the X-axis of Section

≔yc_beam =―― dmin

5.13 in Centroid of Section

≔Q =⋅⎛⎝ -yc_beam yc_top_flange⎞⎠ ATop_flange 8.6 in

First Moment of Area of Top

Flange

App en

Filename:

Computed by: D. SOLANO

Computed on:

Last Saved:

Checked by: H. OCON

Checked on: 1/24/2025

01/24/2025

Q1 Deck Repair.mctx

≔q =abs

⋅Q Vu

Imin

1.23 ―― kip in Shear Flow

≔Beam_Length =+27 ft 2 in 27.17 ft Total Beam Length

≔Ru_total =⋅Beam_Length q 402.32 kip Shear Acting Along the Entire

Length of Beam (Conservative)

≔Rn =⋅0.928 3 ―― kip in

2.78 ―― kip in Shear Capacity of a 3/16" Weld

Treated as a Line

≔Weld_length =――― Ru_total

⋅Rn 2

6.02 ft Required Length of Weld

≔Nweld_Lines 26 Number of Welds on Each side of beam

≔Sweld 10 in Spacing Between Welds

≔Weldlength =――――――――――― -Beam_Length ⋅Sweld ⎛⎝ -Nweld_Lines 1⎞⎠ Nweld_Lines

2.92 in Length of Each Weld Line

≔Rn_total =⋅⋅⋅2 Nweld_Lines Weldlength Rn 423.17 kip Total Shear Capacity

=if ⎛⎝ ,,>Rn_total Ru_total “GOOD” “NG”⎞⎠ “GOOD” Shear Flow Check

At minimum, use a 3/16 weld, 3 inches in length every 10 inches for all welds

App en

Filename:

Computed by: D. SOLANO

Computed on:

Last Saved:

Checked by: H. OCON

Checked on: 1/24/2025

01/24/2025

Q1 Deck Repair.mctx

Entryway Deck Beam

Entryway Deck Beam are to be placed between new CMU doorway and basement stairway, beams are composed of a W-section incased in concrete. Beam have been design only using the steel and do not rely on the concrete for strength or serviceability constrains (See Appendix D).

Geometry

≔Span =+7 ft 8 in 7.67 ft Beam Span

≔TribDeck_beam 5 ft Deck Beam Tributary Width

Load Cases:

Load are based on a unit tributary width

≔D =⋅⋅1.2 DeckLoad TribDeck_beam 368.4 plf Decking Load Including Incased

Concrete

≔L =⋅LiveLoad TribDeck_beam 500 plf Live Load

≔S =⋅SnowLoad TribDeck_beam 104 plf Snow Load

LRFD Load Combinations:

≔LC1 =⋅1.4 D 0.52 klf Load Case 1

≔LC2 =++⋅1.2 D ⋅1.6 L ⋅0.5 S 1.29 klf Load Case 2

≔LC3 =++⋅1.2 D ⋅1.0 L ⋅1.6 S 1.11 klf Load Case 3

≔LCgov =max (( ,,LC1 LC2 LC3)) 1.29408 klf Governing Load Case

App en

Filename:

Computed by: D. SOLANO

Computed on:

Last Saved:

Checked by: H. OCON

Checked on: 1/24/2025

01/24/2025

Q1 Deck Repair.mctx

ENERCALC

Capacities are based on W8x10 Section

≔Mu_Deck_Beam ⋅9.602 kip ft Moment Requirements

(ENERCALC)

≔Vu_Deck_Beam 5 kip Shear Requirements

(ENERCALC)

≔Mn_Deck_Beam ⋅22.53 kip ft Moment Capacity

(ENERCALC)

≔Vn_Deack_beam 40.24 kip Shear Capacity

(ENERCALC)

≔δLive 0.044 in Transient Load Deflection

(ENERCALC)

≔δLive&Dead 0.077 in Total Load Deflection

(ENERCALC)

≔δLive_Allowed =―― Span

0.26 in Allowable Transient

Deflection

≔δLive&Dead_Allowed =―― Span

0.51 in Allowable Total Deflection

=if ⎛⎝ ,,>Mn_Deck_Beam Mu_Deck_Beam “GOOD” “NG”⎞⎠ “GOOD” Negative Bending Check

=if ⎛⎝ ,,>Vn_Deack_beam Vu_Deck_Beam “GOOD” “NG”⎞⎠ “GOOD” Shear Check

=if ⎛⎝ ,,>δLive_Allowed δLive “GOOD” “NG”⎞⎠ “GOOD” Transient Deflection

Check

=if ⎛⎝ ,,>δLive&Dead_Allowed δLive&Dead “GOOD” “NG”⎞⎠ “GOOD” Total Deflection Check

App en

Filename:

Computed by: D. SOLANO

Computed on:

Last Saved:

Checked by: H. OCON

Checked on: 1/24/2025

01/24/2025

Q1 Deck Repair.mctx

Concrete Lentil The concrete lentil/wall and decking are assumed to not act monolithic, however conservatively the lentil has been design to support the wall and 20% of decking live and snow loads. ENERCALC software was use to determine the required reinforcing

(See Appendix E).

Geometry

≔Cc 2 in Reinforcement Clear Cover

≔Wallh 3.5 ft Height of Wall Above Door

≔Wallt 8 in Wall Thickness

≔Lentilt =Wallt 8 in Lentil Thickness

≔Triblent 5.5 ft Deck Tributary Width

≔Span =+7 ft 8 in 7.67 ft Concrete Lentil Beam Span

Load Cases:

Load are based on a unit tributary width

≔D =⋅⋅Wallh Wallt Dc 350 plf Masonry Wall

≔L =⋅⋅LiveLoad Triblent 0.2 110 plf Live Load

≔S =⋅⋅SnowLoad Triblent 0.2 22.88 plf Snow Load

LRFD Load Combinations:

≔LC1 =⋅1.4 D 0.49 klf Load Case 1

≔LC2 =++⋅1.2 D ⋅1.6 L ⋅0.5 S 0.61 klf Load Case 2

≔LC3 =++⋅1.2 D ⋅1.0 L ⋅1.6 S 0.57 klf Load Case 3

≔LCgov =max (( ,,LC1 LC2 LC3)) 0.60744 klf Governing Load Case

App en

Filename:

Computed by: D. SOLANO

Computed on:

Last Saved:

Checked by: H. OCON

Checked on: 1/24/2025

01/24/2025

Q1 Deck Repair.mctx

ENERCALC

≔Mu_lent ⋅4.46 kip ft Moment Requirements

(ENERCALC)

≔Vu_lent 2.4 kip Shear Requirements

(ENERCALC)

≔Mn_lent ⋅12.8 kip ft Moment Capacity

(ENERCALC)

≔Vn_lent =⋅⋅⋅.75 ‾‾‾‾‾⋅fc psi Wallt Wallt 3.04 kip Shear Capacity

(ENERCALC)

=if ⎛⎝ ,,>Mn_lent Mu_lent “GOOD” “NG”⎞⎠ “GOOD” Negative Bending Check

=if ⎛⎝ ,,>Vn_lent Vu_lent “GOOD” “NG”⎞⎠ “GOOD” Shear Check

App en

Filename:

Computed by: D. SOLANO

Computed on:

Last Saved:

Checked by: H. OCON

Checked on: 1/24/2025

01/24/2025

Q1 Deck Repair.mctx

Basement Retaining Wall Basement wall has heavy deterioration requiring demolition, A new retaining wall is proposed. Wall constraints included minimizing size of base and thickness of stem wall as well as base soil cover depth to prevent frost heaving. The wall has been design base on a pin-pin support at bottom and top decking slabs, therefor both decks are to be casted prior to backfilling wall. The following pages are snippets of Tedds software calculator for retaining basement wall. Outputted calculation have been attached on appendix F.

Geometry

App en

Filename:

Computed by: D. SOLANO

Computed on:

Last Saved:

Checked by: H. OCON

Checked on: 1/24/2025

01/24/2025

Q1 Deck Repair.mctx

Load Cases:

App en

Filename:

Computed by: D. SOLANO

Computed on:

Last Saved:

Checked by: H. OCON

Checked on: 1/24/2025

01/24/2025

Q1 Deck Repair.mctx

LRFD Load Combinations:

App en

Filename:

Computed by: D. SOLANO

Computed on:

Last Saved:

Checked by: H. OCON

Checked on: 1/24/2025

01/24/2025

Q1 Deck Repair.mctx

Wall Capacity Check:

App en

Filename:

Computed by: D. SOLANO

Computed on:

Last Saved:

Checked by: H. OCON

Checked on: 1/24/2025

01/24/2025

Q1 Deck Repair.mctx

Ramp Retaining Wall Proposed ramp is to have a retaining wall along parameter. Constraints included minimizing size of base and thickness of stem wall as well as base cover depth to prevent frost heaving. No mechanical connection has been design between retaining wall to ramp slab, therefor, wall is design to act as a cantilever (pinned at the toe). Sizing and capacity checks have been conducted on the tallest section of wall. Due to variable retaining soil height, 4 different base width are use to minimize required concrete pour, all constraint by stability . The following pages are snippets of Tedds software calculator for cantilever retaining wall.

Outputted calculation have been attached on appendix G.

Geometry

Wall Dimensions

2ft base with max stem height of 5.75ft

(soil bearing pressure 1500 psf)

2.75ft base with max stem height of 6.75ft

(soil bearing pressure 1500 psf)

3ft base with max stem height of 7.6ft

(Base on Bedrock)

4.25ft base with max stem height of 5ft

(soil bearing pressure 1500 psf)

App en

Filename:

Computed by: D. SOLANO

Computed on:

Last Saved:

Checked by: H. OCON

Checked on: 1/24/2025

01/24/2025

Q1 Deck Repair.mctx

Load Cases:

Worst Case Show - 4.25ft Width Base

LRFD Load Combinations:

App en

Filename:

Computed by: D. SOLANO

Computed on:

Last Saved:

Checked by: H. OCON

Checked on: 1/24/2025

01/24/2025

Q1 Deck Repair.mctx

Strength Checks

Stem Reinforcement (Worst Case Show - 4.25ft Width Base)

Base Reinforcement (Worst Case Show - 4.25ft Width Base)

App en

Filename:

Computed by: D. SOLANO

Computed on:

Last Saved:

Checked by: H. OCON

Checked on: 1/24/2025

01/24/2025

Q1 Deck Repair.mctx

Transverse Reinforcement (Worst Case Show - 4.25ft Width Base)

Design Summary

App en

Filename:

Computed by: D. SOLANO

Computed on:

Last Saved:

Checked by: H. OCON

Checked on: 1/24/2025

01/24/2025

Q1 Deck Repair.mctx

Stability Check:

2ft base with max stem height of 5.75ft

2.75ft base with max stem height of 6.75ft

3ft base with max stem height of 7.6ft

4.25ft base with max stem height of 5ft

App en

Filename:

Computed by: D. SOLANO Computed on:

Last Saved:

Checked by: [F. LAST] Checked on:

01/15/2025

Q1 References.mcdx

References

App en

Filename:

Computed by: D. SOLANO Computed on:

Last Saved:

Checked by: [F. LAST] Checked on:

01/15/2025

Q1 References.mcdx

References A

App en

ASCE 7-16 Snow Loads LIC# : KW-06014737, Build:20.22.4.26 USACE (c) ENERCALC INC 1983-2022

DESCRIPTION: --None--

Project File: q1 deck.ec6

Project Title:

Engineer:

Project ID:

Project Descr:

Flat Roof Snow Loads Description : Q1 Snow Load per ASCE 7-16, Chapter 7

Ground Snow Load, per Fig 7.2-1 31.00 B (see ASCE 7-16 Section 26.7)Terrain Category

Partially ExposedExposure of Roof 1.00Ce : Exposure Factor, Table 7.3-1

Ct : Thermal Factor1.2 : Unheated and open air structures Risk Category, per Table 1.5-1 I

Importance Factor, Is, Table 1.5-2 0.80

Roof Slope, Sec .7.3.4 0.00

16.00 psfpm, Minimum required pf, Calculated Snow Load per Equation 7-1 20.83 psf psf MonoslopeRoof Configuration pf, Design Snow Load Max(pm min, pf calc) 20.83 psf

App en

Filename:

Computed by: D. SOLANO Computed on:

Last Saved:

Checked by: [F. LAST] Checked on:

01/15/2025

Q1 References.mcdx

References B

App en

General Beam Analysis

DESCRIPTION: --None--

Project File: q1 deck.ec6

Project Title:

Engineer:

Project ID:

Project Descr:

General Beam Properties Elastic Modulus ksi29,000.0

2.860Span #1 in^4Area = in^2 Moment of Inertia =Span Length = 30.406.0 ft 2.860Span #2 in^4Area = in^2 Moment of Inertia =Span Length = 30.405.0 ft 2.860Span #3 in^4Area = in^2 Moment of Inertia =Span Length = 30.405.0 ft 2.860Span #4 in^4Area = in^2 Moment of Inertia =Span Length = 30.405.0 ft 2.860Span #5 in^4Area = in^2 Moment of Inertia =Span Length = 30.406.0 ft

.Service loads entered. Load Factors will be applied for calculations.Applied Loads Loads on all spans...

Uniform Load on ALL spans : D = 0.06140, L = 0.10, S = 0.02083 k/ft, Tributary Width = 1.0 ft

.DESIGN SUMMARY

Maximum Bending =

Load Combination +1.20D+1.60L+0.50S Span # where maximum occurs Span # 1 Location of maximum on span 6.000 ft

0.8732 k

Span # where maximum occurs Location of maximum on span

Span # 1 Load Combination +1.20D+1.60L+0.50S

Maximum Shear =

6.000 ft

0.846 k-ft

Maximum Deflection Max Downward Transient Deflection 0.020 in 3617 Max Upward Transient Deflection -0.002 in 32472 Max Downward Total Deflection 0.032 in 2241 Max Upward Total Deflection -0.003 in 20118

Load Combination Support 1 Support 2 Support 3 Support 4 Support 5 Support 6 Vertical Reactions Support notation : Far left is #1 Values in KIPS

Overall MAXimum 1.0340.391 0.7541.034 0.754 0.391 Overall MINimum +D+L 1.0340.391 0.7541.034 0.754 0.391 D Only 0.3940.149 0.2870.394 0.287 0.149 +D+S 0.5270.199 0.3840.527 0.384 0.199 +D+0.750L 0.8740.330 0.6370.874 0.637 0.330 +D+0.750L+0.750S 0.9740.368 0.7100.974 0.710 0.368 +0.60D 0.2360.089 0.1720.236 0.172 0.089 L Only 0.6410.242 0.4670.641 0.467 0.242 S Only 0.1330.050 0.0970.133 0.097 0.050

App en

Filename:

Computed by: D. SOLANO Computed on:

Last Saved:

Checked by: [F. LAST] Checked on:

01/15/2025

Q1 References.mcdx

References C

App en

More than 2 Spans 6 0

28.14

100.00 0.00

20.80 0.00 0.00 0.00

0.100

180 Not Supporting Glass

Not Considered Not Considered

60 ksi #3 Bars

1.00 12.00

Composite Deck-Slab Multi-Span 1.5VL-36 Composite Steel Deck-Slab (Imperial & LRFD Only) with 3.5 in. 150 pcf 3500 psi NWC

Input additional design criteria for multi‑span calculation:

Span Condition:

Select Deck Gage:

Input Span Length: ft ‑ in.

Note: Per ACI 318‑19 Section 6.5.1 (e), the multi span calculation is permitted for spans ranging from 5'‑0" to 6'‑ 0".

Superimposed Uniform Loads Total Weight, w1 (psf) 33.26 Superimposed Dead Load, DL‑sup (psf) Total Dead Load, DL (psf) 61.40 DL = w1 + DL‑sup Live Load, LL (psf) Roof Live Load, Lr (psf) Snow Load, S (psf) Rain Load, R (psf) Inward Wind Component & Cladding, Wi (psf) Uplift Wind Component & Cladding, Wu (psf) For Deflection, 0.42Wi (psf) 0.00 For Deflection, 0.42Wu (psf) 0.00 Seismic SDS Only required for SDS > 0.125 Earthquake Load, E (psf) 0.000 E = 0.20 x SDS x DL

Serviceability Live Load Deflection l / Snow or Wind Load Deflection l / Total Load Deflection l / Time Dependent Deflection for Dead Load Time Dependent Deflection for Live Load

Reinforcing for Negative Moment Negative Reinforcing Type Rebar Rebar Grade, fy Rebar Size Area of Rebar, As (in.²/bar) 0.110 Reinforcement Depth from Top of Slab, d' (in.) 0.94 ≤ ≤ 1.06 Design Rebar Spacing, s (in. o.c.) 1.38 ≤ ≤ 15.56 Max. Aggregate Size, dagg (in.) 0.67

Note: Developmental length of negative reinforcing in accordance with ACI 318‑19 on last page of this calculation.

Summary of Results Vertical Shear Capacity Pass Positive Moment Capacity Pass Reinforcement for Negative Moment Pass Slab Serviceability (Deflection) Pass

App en

Composite Deck-Slab Multi-Span 1.5VL-36 Composite Steel Deck-Slab (Imperial & LRFD Only) with 3.5 in. 150 pcf 3500 psi NWC

Load Combinations

Load Factors and Combinations (Stress) Per ACI 318‑14 Table 5.3.1

Governing LC (GL+) 244.08 psf Governing LC (GL‑) 0.00 psf LRFD (1) 1.4DL 85.95 psf LRFD (2) 1.2DL+1.6LL+0.5(Lr or S or R) 244.08 psf Controlling Positive LRFD (3) 1.2DL+1.6(Lr or S or R)+(1.0LL or 0.5Wi) 206.96 psf LRFD (4) 1.2DL+1.0Wi+1.0LL+0.5(Lr or S or R) 184.08 psf LRFD (5) 1.2DL+1.0E+1.0LL+0.2S 177.84 psf LRFD (6) 0.9DL‑1.0Wu 55.26 psf LRFD (7) 0.9DL‑1.0E 55.26 psf

Shear & Moment in Composite Slab

Moment and shear values are calculated following ACI 318‑19 Table 6.5.2 and Table 6.5.4 respectively.

At End Span: (+) Inward Loading (‑) Outward Loading

Unrestrained End Span:

(GL+) l²

= 799 lbs‑ft/ft (GL‑) l²

= 0 lbs‑ft/ft 11 11

Exterior Face of First Exterior Support:

(GL+) l²

= ‑879 lbs‑ft/ft (GL‑) l²

= 0 lbs‑ft/ft 10 10

Shear at the face of the first interior support:

1.15 (GL+) l

= 842 lbs/ft

1.15 (GL‑) l

= 0 lbs/ft 2 2

At Interior Span:

Face of All Other Supports:

(GL+) l²

= ‑799 lbs‑ft/ft (GL‑) l²

= 0 lbs‑ft/ft 11 11

Interior Spans:

(GL+) l²

= 549 lbs‑ft/ft (GL‑) l²

= 0 lbs‑ft/ft 16 16

Shear at interior support:

(GL+) l

= 732 lbs/ft (GL‑) l

= 0 lbs/ft 2 2

Governing Positive Moment, M + 799 lbs‑ft/ft Governing Negative Moment, M ‑ ‑879 lbs‑ft/ft Governing Vertical Shear, V 842 lbs/ft

App en with 3.5 in. 150 pcf 3500 psi NWC

Checking Slab for Vertical Shear Capacity Pass ɸVno = 3.26 kip/ft = 3264 lbs/ft > V = 842 lbs/ft OK ɸVno is imported from the LRFD "Composite Steel Deck‑Slab Properties" table from the Summary tab.

22 Gage 1.5VL‑36 is acceptable for vertical shear.

Checking Deck for Positive Moment Capacity Pass ɸMno = 2.77 kip‑ft/ft = 2774 lbs‑ft/ft > M + = 799 lbs‑ft/ft OK ɸMno is imported from the LRFD "Composite Steel Deck‑Slab Properties" table from the Summary tab.

22 Gage 1.5VL‑36 is acceptable for positive moment reinforcement.

Design Reinforcement for Negative Moment Pass

Maximum Negative Moment, Mu 879 lbs‑ft/ft Specified Yield Strength of Reinforcement, fy 60000 psi Concrete Strength, f'c 3500 psi Total Slab Depth, h 3.50 in.

Depth of reinforcement steel from top of slab, d' 1.00 in.

d = h ‑ d' 2.50 in.

Total width of compression, b 12.00 in./ft Pitch of Deck, D 6.00 in.

Nominal Top Flange Width, f 3.50 in.

Nominal Bottom Flange Width, 2e 1.75 in.

Effective width of concrete in compression, bc 4.25 in./ft

Min. Neg. Area of Reinforcement:

Ku = Mu / ( bc d ² ) 397 psi

0.0080

Req. Area of Steel to Resist the Neg. Moment, As min = bc d ρ 0.085 in.²/ft Area of Rebar, As 0.110 in.²/bar Design Rebar Spacing, s 12.00 in. o.c.

Number of Rebar per foot 1.00 per ft.

Area of Steel to Resist Negative Moment, As 0.110 in.²/ft

As = 0.110 in.²/ft > As min = 0.085 in.²/ft OK

App en with 3.5 in. 150 pcf 3500 psi NWC

Design Limitations:

Nominal Diameter of Selected Bar or Wire, db 0.38 in.

Concrete Height, hc 2.00 in.

Panel Height, dd 1.50 in.

(a) Reinforcement Depth from Top of Slab, d' (in.):

Min. d' = 3/4 + 1/2 (db) = 0.94 in. ACI 318‑19 Table 20.5.1.3.1 Max. d' = hc ‑ (0.75 + 0.50 db ) = 1.06 in.

(b) Design Rebar Spacing (in. o.c.):

Min. Rebar Spacing = Max. (1.0 , db) + db = 1.38 in. ACI 318‑19 Section 25.2.1 Max. Rebar Spacing = Min. (s₁ , s₂) = 15.56 in.

s₁ = Max. (18 , 5 (hc + 1/2 dd)) = 18.00 in. ACI 318‑19 Section 12.7.2.2 s₂ = (As / As‑min ) x 12 = 15.56 in.

(c) Max. Aggregate Size, dagg (in.):

Per ACI 318‑19 Section 26.4.2.1(a)(4)

(ii) 1/3 hc = 0.67 in.

(iii) 3/4 the Min. Specified Clear Spacing Between Individual Reinforcing Bars or Wires Clear Spacing = s ‑ db = 11.63 in.

Max. dagg Size = 3/4 (Clear Spacing) = 8.72 in.

Max. dagg = Min. of (ii) & (iii) = 0.67 in.

Check Negative Moment Capacity:

Area of Steel to Resist Negative Moment, As 0.110 in.²/ft Tension‑Controlled Reduction Factor, ɸ 0.90 ACI 318‑19 Table 21.2.2

0.522 in.

ɸMn = ɸ As fy ( d ‑ a / 2 ) 1108 lbs‑ft/ft ɸMn = 1108 lbs‑ft/ft > ‑(M ‑) = 879 lbs‑ft/ft OK

For Tension Control:

β1 = 0.85 ACI 318‑19 Table 22.2.2.4.3 c = a / β1 0.61 in. ACI 318‑19 Eq. 22.2.2.4.1

0.003 ( d ‑ c ) / c = 0.009 > 0.005 OK

The selected negative moment reinforcing steel is acceptable.

App en with 3.5 in. 150 pcf 3500 psi NWC

Checking for Slab Serviceability Pass

Per 2021 IBC Table 1604.3: (LL or Lr) is checked for Live Load deflection limits and (D + LL) is checked for Total Load deflection limits.

Governing Positive Service Load Combination (GLD+) 161.40 psf Per ASCE 7‑16 Governing Negative Service Load Combination (GLD‑) 0.00 psf ASD (1) DL 61.40 psf ASD (2) DL+L 161.40 psf Controlling Positive ASD (3) DL+(Lr or S or R) 82.20 psf ASD (4) DL+0.75L+0.75(Lr or S or R) 152.00 psf ASD (5) DL+(0.6Wi or 0.7E) 61.40 psf ASD (6a) DL+0.75L+0.75(0.6Wi)+0.75(Lr or S or R) 152.00 psf ASD (6b) DL+0.75L+0.75(0.7E)+0.75S 152.00 psf ASD (7) 0.6DL‑0.6Wu 36.84 psf ASD (8) 0.6DL‑0.7E 36.84 psf

Service Load Shear & Moment in Composite Slab

Moment and shear values are calculated following ACI 318‑14 Table 6.5.2 and Table 6.5.4 respectively.

End Span: (+) Inward Loading (‑) Outward Loading

Unrestrained End Span:

(GLD+) l²

= 528 lbs‑ft/ft (GLD‑) l²

= 0 lbs‑ft/ft 11 11

Exterior Face of First Exterior Support:

(GLD+) l²

= ‑581 lbs‑ft/ft (GLD‑) l²

= 0 lbs‑ft/ft 10 10

Interior Span:

Face of All Other Supports:

(GLD+) l²

= ‑528 lbs‑ft/ft (GLD‑) l²

= 0 lbs‑ft/ft 11 11

Interior Spans:

(GLD+) l²

= 363 lbs‑ft/ft (GLD‑) l²

= 0 lbs‑ft/ft 16 16

Governing Negative Moment, M s‑ ‑581 lbs‑ft/ft

App en with 3.5 in. 150 pcf 3500 psi NWC

Effective Moment of Inertia for Nonprestressed Members, Ie, for Negative Bending Over Support(s)

When Ma ≤(2/3)Mcr Ie = Ig ACI 318‑19 Section 24.2.3.5

Ma >(2/3)Mcr

Where, 1.912 in.⁴/ft

Cracking Moment, Mcr = fr ( Ig ) / yt 118.16 lbs‑ft/ft ACI 318‑19 Table 24.2.3.5 Max. Moment due to Service Loads at Def., Ma = ‑(M s‑) 581 lbs‑ft/ft Moment of Inertia of Gross Concrete Section about Centroidal Axis, Neglecting Reinforcement, Ig

2.860 in.⁴/ft

Moment of Inertia of a Cracked Section, Icr 1.900 in.⁴/ft From Summary tab Modulus of Rupture of Concrete, fr = 7.5 sqrt(f'c) = 443.71 psi ACI 318‑19 Section 19.2.3.1 (for NWC = 1.0, for LWC = 0.75) 1.00 ACI 318‑19 Table 19.2.4.2

Span Length, l 6.00 ft.

ρ' for Composite Steel Deck at Mid‑Span 0.015 Modulus of Elasticity of Steel, Es 29500 ksi

Distance from Centroidal Axis of Gross Section, Neglecting Reinforcement, to Tension Face, yt = yb

0.90 in. From Comp. Strength Calc tab

Moment of Inertia for Deflection of Steel Deck, Id 2.86 in.⁴/ft From Comp. Strength Calc tab Moment of Inertia for Multi‑Span Design, Im = (Ie + Id) / 2 = 1.43 in.⁴/ft ACI 318‑19 Section 24.2.3.6

Service Load Combinations (Deflection) Total Dead Load, DL 61.40 psf Live Load, LL 100.000 psf Roof Live Load, Lr 0.000 psf Maximum of LL and Lr is used for serviceability check.

Snow Load, S 20.80 psf Wind Load, W = Max ( Wi ‑ Def, Wu ‑ Def ) 0.00 psf

Check for Live Load Deflection:

Δmax = l / 360 0.20 in.

ΔLL =

LL (l⁴)

= 0.037 in.

145 Es Im

ΔLL = 0.037 in. < Δmax = 0.20 in. OK

Check for Snow or Wind Deflection:

Δmax = l / 180 0.40 in.

Δ(S or W) = (S or W)(l⁴)

= 0.008 in.

145 Es Im

Δ(S or W) = 0.008 in. < Δmax = 0.40 in. OK

App en with 3.5 in. 150 pcf 3500 psi NWC

Check for Total Load Deflection:

Δmax = l / 240 0.30 in.

ΔTL =

(DL+LL)(l⁴)

= 0.059 in.

145 Es Im

ΔTL = 0.059 in. < Δmax = 0.300 in. OK

Time Dependent Deflection

Deflection factor, з, for Not Considered n/a ACI 318‑19 Table 24.2.4.1.3 Factor for long‑term deflection, Δ = з / ( 1 + 50 ρ' ) 1.00 ACI 318‑19 Section 24.2.4.1.1 λΔ (DL) = λΔ (DL) (l⁴)

= 0.022 in.

145 Es Im

Deflection factor, з, for Not Considered n/a ACI 318‑19 Table 24.2.4.1.3 Factor for long‑term deflection, Δ = з / ( 1 + 50 ρ' ) 1.000 ACI 318‑19 Section 24.2.4.1.1 λΔLL = λΔ (LL) (l⁴)

= 0.037 in.

145 Es Im λΔTL = λΔDL + λΔLL = 0.059 in.

λΔTL = 0.059 in. < Δmax = 0.30 in. OK

22 Gage 1.5VL‑36 is acceptable for serviceability.

App en with 3.5 in. 150 pcf 3500 psi NWC

Rebar Developmental and Splice Length

Per ACI 318‑14 Section 25.4.2.1 & 25.4.2.3

12.00 in. ≥ 12 in. ACI 318‑19 Eq. 25.4.2.3a

Where, (cb + Ktr ) / db = 2.50 ≤ 2.5 Transverse Reinforcement Index, Ktr 0 in. ACI 318‑19 Section 25.4.2.4 Nominal Diameter of Selected Bar, db 0.38 in.

Specified Yield Strength of Reinforcement, fy 60000 psi Concrete Strength, f'c 3500 psi (for NWC = 1.0, for LWC = 0.75) 1.00 ACI 318‑19 Table 25.4.2.5 ψt, Casting Position 1.00 ACI 318‑19 Table 25.4.2.5 ψe, Uncoated or Zinc Coated (Galvanized) Reinforcement 1.00 ACI 318‑19 Table 25.4.2.5 ψs, 1.0 for ≥ #7, 0.8 for #6 and Smaller Bars 0.80 ACI 318‑19 Table 25.4.2.5

Min. of (a) & (b), cb 1.00 in.

(a) The Distance From Center of a Bar to Nearest Concrete Surface 1.00 in.

ACI 318‑19 Section 2.2

(b) One‑Half the Center‑to‑Center Spacing of Bars Being Developed 6.00 in.

Lap Splice Lengths of Deformed Bars in Tension ACI 318‑19 Section 25.5.2.1

As, provided / As, reqd.

Maximum Percent of As Spliced Within Required

Lap Length Splice Type

Length of Splice, Over Length of Splice lst

≥ 2.0 50 Class A 1.0 (ld) = 12.0 ≥ 12 in

100 Class B 1.3 (ld) = 15.6 ≥ 12 in < 2.0 All Cases Class B

Composite Deck‑Slab V5.6 is based on: Date: 12/23/2024 ANSI/SDI C‑2017, IAPMO UES ER‑0652, and IAPMO UES ER‑0423

NOTICE: Design defects that could cause injury or death may result from relying on the information in this document without independent verification by a qualified professional. The information in this document is provided “AS IS”. Nucor Corporation and its affiliates expressly disclaim: (i) any and all representations, warranties and conditions and (ii) all liability arising out of or related to this document and the information in it.

App en

Filename:

Computed by: D. SOLANO Computed on:

Last Saved:

Checked by: [F. LAST] Checked on:

01/15/2025

Q1 References.mcdx

References D

App en

Steel Beam

DESCRIPTION: --None--

Project File: q1 deck.ec6

Project Title:

Engineer:

Project ID:

Project Descr:

CODE REFERENCES

Calculations per AISC 360-16, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set : ASCE 7-16

Material Properties Analysis Method :

ksi Bending Axis : Major Axis Bending

Completely Unbraced Load Resistance Factor Design Fy : Steel Yield : 50.0 ksi

Beam Bracing : E: Modulus : 29,000.0

.Service loads entered. Load Factors will be applied for calculations.Applied Loads Beam self weight calculated and added to loading Loads on all spans...

Uniform Load on ALL spans : D = 0.3680, L = 0.50, S = 0.1040 k/ft

.Design OKDESIGN SUMMARY Maximum Bending Stress Ratio = 0.426 : 1

Load Combination +1.20D+1.60L+0.50S

Span # where maximum occurs Span # 1

5.007 k Mn * Phi : Allowable 22.531 k-ft Vn * Phi : Allowable

W8x10Section used for this span

Span # where maximum occurs Location of maximum on span

Span # 1

Load Combination +1.20D+1.60L+0.50S

40.239 k

Section used for this span W8x10 Mu : Applied

Maximum Shear Stress Ratio = 0.124 : 1

7.670 ft

9.602 k-ft Vu : Applied

0 <360

Ratio = 0 <180

Maximum Deflection Max Downward Transient Deflection 0.044 in 2,101Ratio = >=360 Max Upward Transient Deflection 0.000 in Ratio = Max Downward Total Deflection 0.077 in Ratio = >=180 Max Upward Total Deflection 0.000 in

Span: 1 : L Only Span: 1 : +D+L

Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections

+D+L 1 0.0769 3.857 0.0000 0.000

Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS

Overall MAXimum 3.367 3.367 Overall MINimum 0.399 0.399 D Only 1.450 1.450 +D+L 3.367 3.367 +D+S 1.849 1.849 +D+0.750L 2.888 2.888 +D+0.750L+0.750S 3.187 3.187 +0.60D 0.870 0.870 L Only 1.918 1.918 S Only 0.399 0.399

App en

Filename:

Computed by: D. SOLANO Computed on:

Last Saved:

Checked by: [F. LAST] Checked on:

01/15/2025

Q1 References.mcdx

References E

App en

Concrete Beam

DESCRIPTION: --None--

Project File: Q1 deck.ec6

Project Title:

Engineer:

Project ID:

Project Descr:

CODE REFERENCES

Calculations per ACI 318-14, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set : ASCE 7-16

Material Properties 3.0

7.50 145.0

Elastic Modulus 3,122.0 ksi

60.0 29,000.0 3=

= 0.90 0.750 f'c ksi fy - Main Rebar ksi

Density

1/2 fr = f'c * 410.792 pcf

E - Main Rebar ksi psi

= 1.0LtWt Factor Fy - Stirrups ksi

E - Stirrups ksi

0.850

Shear :

Stirrup Bar Size #

Number of Resisting Legs Per Stirrup

Phi Values Flexure :

.Cross Section & Reinforcing Details Rectangular Section, Width = 8.0 in, Height = 8.0 in Span #1 Reinforcing

2-#5 at 2.50 in from Bottom, from 0.0 to 7.667 ft in this span

Load for Span Number 1 Uniform Load : D = 0.350, L = 0.110, S = 0.02275 k/ft, Tributary Width = 1.0 ft

.Design OKDESIGN SUMMARY Maximum Bending Stress Ratio = 0.349 : 1

Span # where maximum occurs Span # 1 Location of maximum on span 3.840 ft

Mn * Phi : Allowable 12.801 k-ft

Typical SectionSection used for this span Mu : Applied 4.463 k-ft

Maximum Deflection

0 <360.0

Ratio = 0 <180.0

Max Downward Transient Deflection 0.008 in 11469Ratio = >=360.0 Max Upward Transient Deflection 0.000 in Ratio = Max Downward Total Deflection 0.041 in Ratio = >=180.0 Max Upward Total Deflection 0.000 in

S Only L Only Span: 1 : +D+L Span: 1 : +D+L

App en

Filename:

Computed by: D. SOLANO Computed on:

Last Saved:

Checked by: [F. LAST] Checked on:

01/15/2025

Q1 References.mcdx

References F

App en

Project Job Ref.

Section Sheet no./rev.

Calc. by

B Date

1/14/2025 Chk'd by Date App'd by Date

RETAINING BASEMENT WALL ANALYSIS & DESIGN

In accordance with ACI 318-19 (22) Tedds calculation version 1.0.01

Design summary

Overall design status; PASS

Overall design utilization; 0.866

Analysis - Combination D + H + L

Description Unit Provided Required Utilization Result Bearing pressure psf 4000 3464.89 0.866 PASS

Design - Combination 1.2D + 1.6H + 1.6L + 0.5Lr

Description Unit Provided Required Utilization Result Pure axial capacity kips/ft 187.79 4.13 0.022 PASS Bending capacity kips_ft/ft 10.52 -6.91 0.657 PASS Shear capacity kips/ft 4.52 3.68 0.814 PASS Foot. bending capacity kips_ft/ft 26.88 0.37 0.014 PASS

Basement wall details

Stem height; hstem = 11 ft

Thickness of stem; tstem = 8 in

Stem area; Astem = hstem tstem = 7.33 ft2

Density; stem = 150 pcf

Fixity at base of the wall; Pinned

Angle to rear face of basement wall; = 90

Retained soil height; hret = 7 ft

Backfill soil angle; = 0

Groundwater level; hwater = 7 ft

Water density; water = 62.3 pcf

Strip footing details

Footing depth; hfooting = 12 in

Toe length; ltoe = 0.58 ft

Heel length; lheel = 0.58 ft

Total length; ltotal = 1.83 ft

Footing area; Afooting = ltotal hfooting = 1.83 ft2

Density; footing = 150 pcf

Footing rotation; Not prevented

Total height; htotal = hstem + hfooting = 12 ft

Effective soil height; heff = hret + hfooting = 8 ft

App en

Calc. by

B Date

1/14/2025 Chk'd by Date App'd by Date

G.L.G.W.L.

8"

11'

7" 7"

1'

1' 10"

7'7'

Loading details

Axial dead load on top of wall ; PD = 0.8 kips/ft

Moment dead load on top of wall; MD = 0.4 kips_ft/ft

Axial live load on top of wall ; PL = 1.1 kips/ft

Moment live load on top of wall; ML = 0.5 kips_ft/ft

Live surcharge load; pL,sur = 200 psf

Axial snow load on top of wall ; PS = 0.2 kips/ft

Moment snow load on top of wall; MS = 0.1 kips_ft/ft

Retained soil properties

Soil type; Soft sandy clay

Moist density; mr = 110 pcf

Moist soil height; hmoist = 0 ft

Saturated density; sr = 110 pcf

Saturated soil height; hsat = 7 ft

Effective internal resistance angle; r = 26

Effective wall friction angle; r = 13

Base soil properties

Gross allowable bearing pressure; Pbearing.Gross = 4000 psf

Using Coulomb theory

At rest pressure coefficient; K0 = 1 - sin(r) = 0.562

ASCE 7-22 load combinations (ASD)

D + H (0.639)

D + H + L (0.866)

D + H + S (0.671)

App en

Calc. by

B Date

1/14/2025 Chk'd by Date App'd by Date

D + H + 0.75L + 0.525S (0.826)

Critical ASD combination results: D + H + L

Lateral pressure

Live surcharge pressure; pL.Surch.Press = K0 cos (r) pL,sur = 109.4 psf

Dead surcharge pressure; pD.Surch.Press = K0 cos (r) pD,sur = 0 psf

Soil pressure at top of retained soil pSoil.Top = 0 psf

Soil pressure at groundwater level pSoil.WaterLevel = K0 cos (r) hmoist mr = 0 psf

Soil pressure at footing; pSoil.Footing = K0 cos (r) (hmoist mr + (hret + hfooting - hmoist) (sr - water)) =

208.8 psf

Water pressure at footing; pWater.Footing = water (hwater + hfooting) = 498.4 psf

G.W.L.

109 psf

728 psf

817 psf

109 psf 200 psf

1.96 kips/ft

0.85 kips_ft/ft

796 psf 3465 psf

Reactions at base of stem (from 2D analysis model)

Axial RV.StemBase = 3064 plf

Shear RH.StemBase = 2306 plf

Moment RM.StemBase = 0 lb_ft/ft

Bearing pressure check

Vertical forces

Stem; FV.Stem = Astem stem = 1100 plf

Footing; FV.Footing = Afooting footing = 275 plf

Retained soil; FV.Soil = hmoist lheel mr + hsat lheel (sr - water) = 195 plf

Surcharge load; FV.Surch = pL,sur lheel = 117 plf

Applied axial loads; FV.Applied = PD + PL = 1964 plf

Water; FV.Water = hwater lheel water = 254 plf

Total; FV.Total = FV.Stem + FV.Footing + FV.Soil + FV.Surch + FV.Applied + FV.Water = 3905 plf

App en

Calc. by

B Date

1/14/2025 Chk'd by Date App'd by Date

Horizontal forces

Stem; FH.Stem = RH.StemBase = 2306 plf

Retained soil; FH.Soil = (pSoil.WallBase + 0.5 (pSoil.Footing - pSoil.WallBase)) hfooting = 196 plf

Distance; DFH.Soil = hfooting (2 / 3 pSoil.WallBase + pSoil.Footing / 3) / (pSoil.WallBase + pSoil.Footing)

= 0.489 ft

Surcharge load; FH.Surch = pL.Surch.Press hfooting = 109 plf

Water; FH.Water = (pWater.WallBase + 0.5 (pWater.Footing - pWater.WallBase)) hfooting = 467 plf

Distance; DFH.Water = hfooting (2 / 3 pWater.WallBase + pWater.Footing / 3) / (pWater.WallBase + pWater.Footing) = 0.489 ft

Prop; FH.Prop = FH.Stem + FH.Soil + FH.Surch + FH.Water = 3079 plf

Total; FH.Total = FH.Stem + FH.Soil + FH.Surch + FH.Water - FH.Prop = 0 plf

Moments

Stem; MStem = RV.StemBase (ltoe + tstem / 2) - RH.StemBase hfooting - RM.StemBase = 502 lb_ft/ft

Footing; MFooting = FV.Footing ltotal / 2 = 252 lb_ft/ft

Retained soil; MSoil = FV.Soil (ltoe + tstem + lheel / 2) - FH.Soil DFH.Soil = 204 lb_ft/ft

Surcharge load; MSurch = FV.Surch (ltoe + tstem + lheel / 2) - FH.Surch hfooting / 2 = 125 lb_ft/ft

Water; MWater = FV.Water (ltoe + tstem + lheel / 2) - FH.Water DFH.Water = 163 lb_ft/ft

Horizontal base prop; MH.Prop = FH.Prop hfooting = 3079 lb_ft/ft

Total; MTotal = MStem + MFooting + MSoil + MSurch + MWater + MH.Prop = 4325 lb_ft/ft

Bearing pressure check

Distance to reaction; x = MTotal / FV.Total = 1.11 ft

Eccentricity of reaction; e = x - ltotal / 2 = 0.19 ft

Loaded length of base; LLoad = ltotal = 1.83 ft

Bearing pressure at toe; qtoe = FV.Total / ltotal (1 - 6 e / ltotal) = 796 psf

Bearing pressure at heel; qheel = FV.Total / ltotal (1 + 6 e / ltotal) = 3465 psf

Gross allowable bearing pressure; Pbearing.Gross = 4000 psf

Allowable bearing pressure capacity; qallow = Pbearing.Gross = 4000 psf max(qtoe,qheel) / qallow = 0.866

PASS - Allowable bearing capacity exceeds maximum applied bearing pressure

Basement wall design

Concrete properties

Compressive strength of concrete; f'c = 4000 psi

Concrete modification factor; = 1

Concrete modulus of elasticity - cl 19.2.2.1; Ec = (stem / 1 lb/ft3)1.5 33 (f'c 1 psi) = 3834254 psi

Reinforcement properties

Reinforcement yield strength; fy = 60000 psi

Reinforcement modulus of elasticity; Es = 29000000 psi

Compression-controlled strain limit; ty = 0.002

Max. usable strain at ext. concrete comp. fiber; cu = 0.003

Nominal cover to wall front reinforcement; cnom.front = 3.38 in

Nominal cover to footing top reinforcement; cnom.foot.top = 1.5 in

App en

Calc. by

B Date

1/14/2025 Chk'd by Date App'd by Date

Nominal cover to footing bottom reinforcement; cnom.foot.bot = 1.5 in

Wall vertical reinforcement details

Reinforcement provided; 1 Layer of No. 5 bars at 6 in c/c

Bar diameter; Stem.V = 0.625 in

Area of reinforcement provided; As.prov.Stem.V = 1 Stem.V 2 / (4 sStem.V) = 0.614 in2/ft

Maximum allowable spacing - cl. 11.7.2.1; smax.Stem.V = min(3 tstem, 18 in) = 18 in

PASS - Maximum allowable spacing exceeds reinforcement spacing

Min.area required per foot length - Table 11.6.1; As.min.Stem.V = 0.0012 tstem = 0.115 in2/ft

PASS - Reinforcement provided exceeds minimum reinforcement required

Wall horizontal reinforcement details

Reinforcement provided; 1 Layer of No. 4 bars at 12 in c/c

Bar diameter; Stem.H = 0.5 in

Area of reinforcement provided; As.prov.Stem.H = 1 Stem.H 2 / (4 sStem.H) = 0.196 in2/ft

Maximum allowable spacing - cl. 11.7.3.1; smax.Stem.H = min(3 tstem, 18 in) = 18 in

PASS - Maximum allowable spacing exceeds reinforcement spacing

Min.area required per foot length - Table 11.6.1; As.min.Stem.H = 0.0020 tstem = 0.192 in2/ft

PASS - Reinforcement provided exceeds minimum reinforcement required

Footing longitudinal reinforcement details

Reinforcement provided; No. 5 bars at 6 in c/c

Bar diameter; Foot.long = 0.625 in

Area of reinforcement provided; As.prov.Foot.long = Foot.long 2 / (4 sFoot.long) = 0.614 in2/ft

Maximum allowable spacing - cl. 7.7.2.3; smax.Foot.long = min(3 hfooting, 18 in) = 18 in

PASS - Maximum allowable…