Attachment 0002- Pit Tempering Furnace Comply Sheet- WVA Spec.pdf
PDF 31 KB Posted
- Attached to
- Pit Tempering Furnace Solicitation Federal contract opportunity
- Solicitation number
- W911PT23Q0036
About this file
This document contains a comply sheet for a pit tempering furnace solicitation from the Department of the Army Materiel Command Contracting Command Detroit Arsenal. The comply sheet lists over 100 technical requirements and specifications for a pit tempering furnace against specification number 12-22-3424. Offerors are required to indicate whether their solution complies with each requirement or provide justification for any non-compliance. The related federal contract opportunity provides additional details on solicitation number W911PT23Q0036 for one pit tempering furnace, with a response due date of March 17, 2023. The opportunity is posted by the Department of the Army Materiel Command Contracting Command Detroit Arsenal.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 23Q0036.docx | DOCX document | |
| Attachment 0001- New Pit Tempering Furnace- WVA Spec.pdf | ||
| Exhibit A- CDRLs.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Page 1 Pit Tempering Furnace
Spec Number 12-22-3424
1.0
1.1
3.1
3.2
3.3
3.3.1
3.3.2
3.4
3.5
3.6
3.7
3.7.1
3.7.2
FOR NON-COMPLIANCE, JUSTIFICATION OR ALTERNATIVE/EQUIVALENT
OFFER
NON-
COMPLY
COMPLYPARAGRAPH
OFFEROR'S STATEMENT OF COMPLIANCE
AUTHORIZED SIGNATURE
Page 2 Pit Tempering Furnace
FOR NON-COMPLIANCE, JUSTIFICATION OR ALTERNATIVE/EQUIVALENT
OFFER
NON-
COMPLY
COMPLYPARAGRAPH
OFFEROR'S STATEMENT OF COMPLIANCE
3.7.3
3.7.4
3.7.5
3.7.6
3.8
3.8.1
3.9
3.9.1
3.9.2
3.9.3
3.9.4
3.9.5
3.9.6
3.9.7
3.9.8
Page 3 Pit Tempering Furnace
FOR NON-COMPLIANCE, JUSTIFICATION OR ALTERNATIVE/EQUIVALENT
OFFER
NON-
COMPLY
COMPLYPARAGRAPH
OFFEROR'S STATEMENT OF COMPLIANCE
3.9.9
3.10
3.11
3.12
3.13
3.13.1
3.13.2
3.13.2.1
3.13.2.2
3.14
3.14.1
3.14.2
3.14.3
3.15
3.16
Page 4 Pit Tempering Furnace
FOR NON-COMPLIANCE, JUSTIFICATION OR ALTERNATIVE/EQUIVALENT
OFFER
NON-
COMPLY
COMPLYPARAGRAPH
OFFEROR'S STATEMENT OF COMPLIANCE
3.17
3.18
3.19
3.20
3.20.1
3.20.2
3.20.3
3.20.4
3.20.5
3.20.6
3.20.7
3.20.8
3.20.9
3.20.10
3.20.11
Page 5 Pit Tempering Furnace
FOR NON-COMPLIANCE, JUSTIFICATION OR ALTERNATIVE/EQUIVALENT
OFFER
NON-
COMPLY
COMPLYPARAGRAPH
OFFEROR'S STATEMENT OF COMPLIANCE
3.20.12
3.21
3.22
3.23
3.24
3.25
3.26
3.27
3.28
3.29
4.1
4.1.1
4.1.2
4.2
Page 6 Pit Tempering Furnace
FOR NON-COMPLIANCE, JUSTIFICATION OR ALTERNATIVE/EQUIVALENT
OFFER
NON-
COMPLY
COMPLYPARAGRAPH
OFFEROR'S STATEMENT OF COMPLIANCE
4.2.1
4.2.2
4.2.3
4.2.4
4.3
4.3.1
4.3.2
4.4
5.1
5.2
5.3
5.3.1
5.3.2
5.3.2.1
Page 7 Pit Tempering Furnace
FOR NON-COMPLIANCE, JUSTIFICATION OR ALTERNATIVE/EQUIVALENT
OFFER
NON-
COMPLY
COMPLYPARAGRAPH
OFFEROR'S STATEMENT OF COMPLIANCE
5.3.2.2
5.3.2.3
5.3.2.4
5.3.2.5
5.3.2.6
5.3.2.8
5.5
5.5.4
5.5.4.1
5.5.4.2
5.5.4.3
5.5.4.4
5.5.4.5
5.5.4.6
5.5.4.7
Page 8 Pit Tempering Furnace
FOR NON-COMPLIANCE, JUSTIFICATION OR ALTERNATIVE/EQUIVALENT
OFFER
NON-
COMPLY
COMPLYPARAGRAPH
OFFEROR'S STATEMENT OF COMPLIANCE
5.5.4.8
5.5.5
5.5.6
6.1
6.1.1
6.1.2
6.1.3
6.1.5
6.1.6
6.1.7
6.1.8
6.1.8.1
6.1.8.2
6.1.8.3
Page 9 Pit Tempering Furnace
FOR NON-COMPLIANCE, JUSTIFICATION OR ALTERNATIVE/EQUIVALENT
OFFER
NON-
COMPLY
COMPLYPARAGRAPH
OFFEROR'S STATEMENT OF COMPLIANCE
6.1.8.4
6.2
6.2.1
6.2.2
6.2.3
6.2.4
7.1
7.2
7.3
7.3.1
7.3.2
7.3.3
7.3.4
7.3.5
Page 10 Pit Tempering Furnace
FOR NON-COMPLIANCE, JUSTIFICATION OR ALTERNATIVE/EQUIVALENT
OFFER
NON-
COMPLY
COMPLYPARAGRAPH
OFFEROR'S STATEMENT OF COMPLIANCE
7.3.6
7.4
7.5
7.6
7.7
7.8
Enclosure A
Enclosure B
Enclosure C
Enclosure D
Enclosure E
Enclosure F