This document contains a comply sheet for a pit tempering furnace solicitation from the Department of the Army Materiel Command Contracting Command Detroit Arsenal. The comply sheet lists over 100 technical requirements and specifications for a pit tempering furnace against specification number 12-22-3424. Offerors are required to indicate whether their solution complies with each requirement or provide justification for any non-compliance. The related federal contract opportunity provides additional details on solicitation number W911PT23Q0036 for one pit tempering furnace, with a response due date of March 17, 2023. The opportunity is posted by the Department of the Army Materiel Command Contracting Command Detroit Arsenal.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Attachment 0001- New Pit Tempering Furnace- WVA Spec.pdf | ||
| Exhibit A- CDRLs.pdf | ||
| 23Q0036.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Page 1 Pit Tempering Furnace
Spec Number 12-22-3424
1.0
1.1
3.1
3.2
3.3
3.3.1
3.3.2
3.4
3.5
3.6
3.7
3.7.1
3.7.2
FOR NON-COMPLIANCE, JUSTIFICATION OR ALTERNATIVE/EQUIVALENT
OFFER
NON-
COMPLY
COMPLYPARAGRAPH
OFFEROR'S STATEMENT OF COMPLIANCE
AUTHORIZED SIGNATURE
Page 2 Pit Tempering Furnace
FOR NON-COMPLIANCE, JUSTIFICATION OR ALTERNATIVE/EQUIVALENT
OFFER
NON-
COMPLY
COMPLYPARAGRAPH
OFFEROR'S STATEMENT OF COMPLIANCE
3.7.3
3.7.4
3.7.5
3.7.6
3.8
3.8.1
3.9
3.9.1
3.9.2
3.9.3
3.9.4
3.9.5
3.9.6
3.9.7
3.9.8
Page 3 Pit Tempering Furnace
FOR NON-COMPLIANCE, JUSTIFICATION OR ALTERNATIVE/EQUIVALENT
OFFER
NON-
COMPLY
COMPLYPARAGRAPH
OFFEROR'S STATEMENT OF COMPLIANCE
3.9.9
3.10
3.11
3.12
3.13
3.13.1
3.13.2
3.13.2.1
3.13.2.2
3.14
3.14.1
3.14.2
3.14.3
3.15
3.16
Page 4 Pit Tempering Furnace
FOR NON-COMPLIANCE, JUSTIFICATION OR ALTERNATIVE/EQUIVALENT
OFFER
NON-
COMPLY
COMPLYPARAGRAPH
OFFEROR'S STATEMENT OF COMPLIANCE
3.17
3.18
3.19
3.20
3.20.1
3.20.2
3.20.3
3.20.4
3.20.5
3.20.6
3.20.7
3.20.8
3.20.9
3.20.10
3.20.11
Page 5 Pit Tempering Furnace
FOR NON-COMPLIANCE, JUSTIFICATION OR ALTERNATIVE/EQUIVALENT
OFFER
NON-
COMPLY
COMPLYPARAGRAPH
OFFEROR'S STATEMENT OF COMPLIANCE
3.20.12
3.21
3.22
3.23
3.24
3.25
3.26
3.27
3.28
3.29
4.1
4.1.1
4.1.2
4.2
Page 6 Pit Tempering Furnace
FOR NON-COMPLIANCE, JUSTIFICATION OR ALTERNATIVE/EQUIVALENT
OFFER
NON-
COMPLY
COMPLYPARAGRAPH
OFFEROR'S STATEMENT OF COMPLIANCE
4.2.1
4.2.2
4.2.3
4.2.4
4.3
4.3.1
4.3.2
4.4
5.1
5.2
5.3
5.3.1
5.3.2
5.3.2.1
Page 7 Pit Tempering Furnace
FOR NON-COMPLIANCE, JUSTIFICATION OR ALTERNATIVE/EQUIVALENT
OFFER
NON-
COMPLY
COMPLYPARAGRAPH
OFFEROR'S STATEMENT OF COMPLIANCE
5.3.2.2
5.3.2.3
5.3.2.4
5.3.2.5
5.3.2.6
5.3.2.8
5.5
5.5.4
5.5.4.1
5.5.4.2
5.5.4.3
5.5.4.4
5.5.4.5
5.5.4.6
5.5.4.7
Page 8 Pit Tempering Furnace
FOR NON-COMPLIANCE, JUSTIFICATION OR ALTERNATIVE/EQUIVALENT
OFFER
NON-
COMPLY
COMPLYPARAGRAPH
OFFEROR'S STATEMENT OF COMPLIANCE
5.5.4.8
5.5.5
5.5.6
6.1
6.1.1
6.1.2
6.1.3
6.1.5
6.1.6
6.1.7
6.1.8
6.1.8.1
6.1.8.2
6.1.8.3
Page 9 Pit Tempering Furnace
FOR NON-COMPLIANCE, JUSTIFICATION OR ALTERNATIVE/EQUIVALENT
OFFER
NON-
COMPLY
COMPLYPARAGRAPH
OFFEROR'S STATEMENT OF COMPLIANCE
6.1.8.4
6.2
6.2.1
6.2.2
6.2.3
6.2.4
7.1
7.2
7.3
7.3.1
7.3.2
7.3.3
7.3.4
7.3.5
Page 10 Pit Tempering Furnace
FOR NON-COMPLIANCE, JUSTIFICATION OR ALTERNATIVE/EQUIVALENT
OFFER
NON-
COMPLY
COMPLYPARAGRAPH
OFFEROR'S STATEMENT OF COMPLIANCE
7.3.6
7.4
7.5
7.6
7.7
7.8
Enclosure A
Enclosure B
Enclosure C
Enclosure D
Enclosure E
Enclosure F
File details come from the government source that posted it. Updated .