Attachment 0001 - AED Req.pdf

PDF 6 KB Posted

Attached to
Overhaul of the CH-47 Drive Adapter Assembly
Solicitation number
W58RGZ-20-R-0068
Issued by

View the file

Other files

File Type Posted
W58RGZ20R0068-0002.pdf PDF
Attachment 0013 - Contractor Repair TAV-C Requirements.docx DOCX document
Attachment 0014 - AMC_LMP_TAVC_Portal_User_Access_Procedures.pdf PDF
W58RGZ-20-R-0068 Amend 0001.pdf PDF
Attachment 0010 - Small Business Participation Plan Evaluation.pdf PDF
W58RGZ20R0068.pdf PDF
Attachment 0002 - Frozen Plan Description and Guidance.pdf PDF
Attachment 0006 - Section M - Evaluation Factors For Award- Solicitation Provisions.docx DOCX document
Attachment 0008 - CAGE Code and Cognizant DCMA-DCAA Info.xlsx XLSX spreadsheet
Attachment 0007 - Pricing Template.xlsx XLSX spreadsheet
Attachment 0009 - Past Performance Evaluation Questionnaire Form.pdf PDF
A006 - DD Form 1348-1A.pdf PDF
Attachment 0005 - Section L- Proposal Preparation Instructions.docx DOCX document
A005 - Gov Property Inventory Report.pdf PDF
A007 - Process Plan.pdf PDF
Attachment 0011 - Report of Discrepancy Guidance.pdf PDF
Attachment 0012 - 1348-1A Guidance.pdf PDF
Attachment 0003 M and O Plan Guidance.xlsx XLSX spreadsheet
A001 - TAMMS A.pdf PDF
A004 - Report of Shipping and Packaging Discrepancy.pdf PDF
Attachment 0004 - Packaging.pdf PDF
A003 - Quality Deficiency Report.pdf PDF
A002 - Contract Depot Maintenance Production Report.pdf PDF
Show all 23

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

11/12/2019

M146PRID 145D3407-7Part Number

1615-01-140-6703NSN CH-47System

DRIVE ADAPTER ASSEMBLYNomenclature

YAdequate DMWR Available?

DMWR-55-1615-322DMWR ID

11/11/2016DMWR Date

DMWR Chg #

YPre-Award Survey Recommended?

NCorrelation Performance Study Required ? YPVA Recommended?

- DMWR 55-1615-322 dated 11 November 2016 is in IADS.

- Magnetic particle inspection is a critical characteristic. Magnetic particle inspection shall be done as per ASTM E1444 for cracks. None allowed.

- Component plating amd subsequent bake is a critical characteristic and is required per the overhaul process. Contractor shall acquire proper plating facilities and/or equipment to perform the outlined procedures.

- Shot peening coverage is a critical characteristic. An AMCOM/CCDEVCOM approved source shall be utilized when shot peening is a critical process. Approved sources shall be obtained from AMCOM.

- Balance of the assembly within limits and recording by serial number and part number is a critical characteristic.

- The applied torque during assembly is a critical characteristic as follows. Torque nut/bolt (P/N BACN10RJ9N) onto bolt (P/N 114D3053-3) to 1000 to 1100 inch-pounds (wet). Turn nut only. Hold bolt head firmly to prevent bolt from turning. Lubricate all threads with MIL-PRF-7808 or MIL-PRF-23699 oil.

Identify Any Special Processes, Test Procedures, and/or Instructions

YCritical Safety Item?

Per coordination with Cargo Division, there are no emerging airworthiness issues, new ECP affecting CSI, concerns over reliability, durability issues that would affect the overhaul of the subject item in its current configuration.

Special Airworthiness Considerations

FCDD-AMA-M-Sustainment has verified the CSI/NST status through the ARISE CIM on 25 June 2019 and the NHA is CSI and NST. The subcomponents are CSI and Non-NST. Endurance, Fatigue, and Interchange are not required for overhaul. Updated NHA table in ARISE database. No other changes. DEM

Other Requirements / Comments

If the item is not a CSI and no adequate DMWR is available, approved sources, if any, are listed by CAGE as follows:

NSpecial Post-Contract Award Requirements?

The Prime or OEM is required to submit a Frozen Plan 30 days after contract award to Engineering Directorate (ED) and Aviation Engineering Directorate (AED). The Frozen Plan will be reviewed and require approval by ED and AED prior to government acceptance of contract deliverable assets.

Other Requirements / Comments (Part II)

The applicable DMWR contains detailed procedures regarding IUID requirements for this component. These procedures can be found in MEOs D2106, D2107, and D2108.

Other Requirements / Comments (Part III)

FCDD-AMA-M-Sustainment has re-verified the CSI/NST status through the ARISE CIM on 7 August 2019 and the NHA is CSI and NST. The subcomponents are CSI and Non-NST. Endurance, Fatigue, and Interchange are not required for overhaul. No changes made. DEM

Other Requirements / Comments (Part IV)

Other Requirements / Comments (Part V)

YDoes QE-STD-2 Apply?

Y

Additional CSI Requirements

CSI Contains CSI Replacement Parts? YEngineering Testing Required?

The Contractor shall flow down the Critical Characteristics and QE-STD-1 to all Suppliers of CSIs.

The solicitation/RFP shall require that all proposals/responses include a special tooling and test equipment section that addresses the contractor's plan to meet all government special tooling and test equipment requirements with either:

1. Physical possession of the required tools, 2. Confirmed requisitions for the required tools, 3. Confirmed arrangements for subcontracting the processes requiring the special tools, or 4. Specific plans describing their technical approach to develop equivalent tools.

RStatus

YTDPL?

01/01/1987Approved Date

M&O AED REQUIREMENTS DATA

Commerciality Determination

Commercial Item? N NBest Commercial Practice Acceptable?

1615-01-140-6703NSN CH-47System

Special Post-Contract Award Requirements

RStatus

Correlation Performance Study Requirements

1615-01-140-6703NSN CH-47System

C4598

D1718

D2106

D2107

D2108

D2128A

D2133A

D2145

D2148

D2212

D2213

D2214

D2215

D2216

D2217

D2218

D2219

D2220A

D2221

D2222

D2223

D2224

D2225B

D2226A

D2227

D2228

D2229

D2230

D2231

D2232

D2233

D2234

D2235

D2236

D2237

D2238

D2283

D2466

D2501

D2517

D2556

D2576

D2579

D2584

D2598

D2635

See Table 2-1 Special Tools and Equipment and Table 2-2 Inspection and Test Equipment.

Critical Tools and Test and Inspection Equipment Requiring AED Approval for Substitutes

MEOs Required for Competitive Contract?

RStatus

File details come from the government source that posted it. Updated .