Attach J.3 - Drawings - 4 Pages.pdf

PDF 1 MB Posted

Attached to
Price Yard Building Electrical and Heating Federal contract opportunity
Solicitation number
1240LT25Q0042
Issued by
Department of Agriculture Forest Service

About this file

The file is a set of technical drawings for the Price Yard Storage Electrical and Heating project for the USDA Forest Service's Manti-La Sal National Forest in Carbon County, Utah. The four-page drawing set covers electrical and heating system details for a fire storage building, including a site plan, electrical floor plan, and heating system specifications.

Key technical details include a new electrical service lateral, a Square D panelboard with 120/240 VAC single-phase power, 12 total luminaires (9 surface/ceiling LED lights and 3 wall-mounted LED lights), GFCI receptacles, rollup door operators, and a Modine Effinity unit heater mounted 14 feet above the floor. The drawings specify installation requirements such as underground conduit, concrete-encased grounding, and gas line connections, with operational requirements including a thermostat set to 40°F and an override capability to 68°F for 1-4 hour periods.

View the file

Other files for this federal contract opportunity

Other files attached to Price Yard Building Electrical and Heating, newest first.
File Type Posted
Attach J.7 - Past Performance Form.pdf PDF
SF1442 1240LT25Q0042 - Final.pdf PDF
Attach J.2 - SOW and Specifications - 42 Pages.pdf PDF
Attach J.1 - Schedule of Items.pdf PDF
Attach J.6 - Question and Answer Sheet.pdf PDF
Attach J.5 - Contractor Experience Questionaire - Pages.pdf PDF
Attach J.4 - WD UT20250070 dtd 5-23-25.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PROJECT LOCATION

VICINITY MAP

TRAVEL DIRECTIONS:

SHEET OF

United States Department of Agriculture

Forest Service

INDEX OF SHEETS

SHEET SHEET TITLE NO

G001 COVER SHEET 1

E100 GENERAL 2

E200 ELECTRICAL FLOOR PLAN 3

M100 BID OPTION 2: HEATING SYSTEM 4

FROM THE MANTI-LA SAL SUPERVISORS OFFICE (599 WEST PRICE

RIVER DRIVE, PRICE, UT) HEAD WEST ON WEST PRICE RIVER DRIVE.

TURN RIGHT ONTO W 100 N/W 1ST N ST FOR ABOUT A MILE. TURN

LEFT ONTO N 300 E FOR ONE MILE. TURN RIGHT ONTO E 8TH N,

FOLLOW FOR 0.6 MI. TURN LEFT ONTO N 100 E, THE PRICE YARD IS

ON THE LEFT.

RECOMMENDED BY:

APPROVED:

DIRECTOR OF ENGINEERING

DATE

FOREST SUPERVISOR DATE

PRICE YARD FIRE STORAGE:

ELECTRICAL AND HEATING

UTAH

CARBON COUNTY

MANTI-LA SAL NATIONAL FOREST

(R04) INTERMOUNTAIN REGION

JarenMcCourt Stamp caseymiller Stamp

O E

O E

O E

O E

O E

O E

O E

E

E

50' 0 100' 200'

DRAWN

DESIGNER

STAMPS, LOGOS, AND SEALS

PROJECT NAME

DRAWING TITLE

CHECKED

ARCHIVE NO.

DATE

PROJECT NO.

DRAWING SHEET NO.

DATENO.

REVISION / ISSUE

OFSHEET

United States Department of Agriculture Forest Service

/30

/24

:5 0 J

AR

EN

MC

CO

UR

T C :\U

SE

RS

\JA

RE

NM

CC

OU

RT

\B

OX

\E

NG

DE

SI

GN

\M

AN

TI

LA

SA

L\

PR

IC

E.

YA

RD

.F

IR

EE

NG

IN

EB

UI

LD

IN

G.

\D W

G\

DR

AW

IN

GS

.E

LE

C_

RE

V1

.D W

G

R-4

INTERMOUNTAIN REGION

PRICE YARD

STORAGE:

ELECTRICAL

MANTI-LASAL NATIONAL

FOREST

PRICE RANGER DISTRICT

GENERAL

10/05/2021

S.BROWN

S.BROWN

D.JEPPSEN

E100 002 004

LUMINAIRE SCHEDULE

TYPE DESCRIPTION MANUFACTURER MODEL # LAMPS MOUNTING

Qty

NOTES:

A 4' LINEAR LED LITHONIA CLX L48 10000LM SEF MVOLT 35K 80CRI WH 77W LED SURFACE/CEILING 9 TWO ARE CHAIN MOUNTED AT LOWER ELEVATION

B WALL PACK LED LITHONIA WPX2 LED 30K MVOLT PE DDBXD 47W LED SURFACE/WALL 2

(E) INDICATES WIRE TO SECURITY/EMERGENCY CIRCUIT

C WALL PAK LED LITHONIA WPX1 LED P1 30K MVOLT PE DDBXD 11W LED SURFACE/WALL 1 UNSWITCHED

TOTAL 12

GENERAL LEGEND

COMBINATION METER MAIN/PANELBOARD "X"

4X4 OR 6X6 METAL WIRE TROUGH, 24" LONG

MINIMUM

UNDERGROUND ELECTRICAL LINE, NEW

OVERHEAD ELECTRICAL LINE, EXISTING

USED TO INDICATE BID OPTION EQUIPMENT

CONNECTIONS

THERMOSTAT CONTROLS IN BID OPTION 2

LINEAR LUMINAIRE, TYPE "X", LOWER CASE LETTER

INDICATES SWITCH GROUP. MOUNTING STYLE:

SURFACE AND SUSPENDED

LUMINAIRE, TYPE "X", LOWER CASE LETTER

INDICATES SWITCH GROUP. MOUNTING STYLE: WALL

SWITCH, SINGLE POLE. TYPICAL: LOWER CASE

LETTERS INDICATE SWITCH CONTROL GROUP

SWITCH, 3-WAY

SWITCH, 4-WAY

DISCONNECT SWITCH, LOCKABLE IN BID OPTION 2

RECEPTACLE, DUPLEX, MOUNT AT 36-INCHES

HARDWIRED AC CARBON MONOXIDE ALARM WITH

DIGITAL DISPLAY, KIDDE KN-COP-IC, MOUNT AT

52-INCHES

X-#

CIRCUIT TAG: "X" INDICATES PANEL, AND "#" IS THE

CIRCUIT NUMBER

BRANCH CIRCUIT: o - INDICATES GROUND, LONG LINE

- "NEUTRAL" OR "GROUNDED CONDUCTOR" AND THE

SHORT LINE - "HOT" OR "LINE" CONDUCTORS

M

PANEL X

E

OE

J

T a

X a

X

X a

S a

S

S

S

L

S

C

PANEL A SCHEDULE

TYPE: SQUARE D [QC3040M200S]

120/240 VAC

1 PHASE

A.I.C.: 22,000

FLUSH MOUNT

UNDERGROUND SERVICE: PROVIDE TRENCH

(24" MIN. TO TOP OF CONDUIT) AND SIZE 3

CONDUIT FROM POLE

GROUNDING: #4 CU GRD TO EXISTING CONCRETE ENCASED

ELECTRODE, SEE SPECIFICATIONS

CKT LOAD DESCRIPTION WATTS BREAKER AWG

LOAD

(WATTS)

AWG BREAKER WATTS LOAD DESCRIPTION CKT

A B

1 RECEPTACLES - EAST WALL SOUTH TWO 360 QO120GFI 12 1160 14 QO115 800 LIGHTS 2

3 RECEPTACLE - ICE MACHINE 1500 QO120GFI 12 1500 4

5 RECEPTACLES - AT NORTH ROLLUP DOOR 360 QO120GFI 12 360 6

7 RECEPTACLES - WEST WALL 360 QO120GFI 12 360 8

9 RECEPTACLES - AT SOUTH ROLLUP DOOR 360 QO120GFI 12 360 10

11 #### 12

13 #### 14

15 #### 16

17 #### 18

19 #### 20

21 #### 22

23 #### 24

25 #### 26

27 #### 28

29 #### 30

CODE CALCULATED TOTAL LOAD (WATTS):

LOAD PER PHASE:

(WATTS)

1880 1860

SITE PLAN

FIRE STORAGE BUILDING

GRAVEL

PAD

ASPHALT REPAIR

UTILITY POLE

E

A S

T

INSTALLATION NOTES

1. THE CONTRACTOR SHALL COORDINATE WORK WITH PRICE CITY UTILITIES

FOR THE INSTALLATION OF A NEW ELECTRICAL SERVICE TO THE FIRE

STORAGE BUILDING. SERVICE TRENCH AND CONDUIT SHALL MEET

REQUIREMENTS OF ROCKY MOUNTAIN POWER "ELECTRICAL SERVICE

REQUIREMENTS" CHAPTER 5. METER BASE AND OTHER REQUIREMENTS OF

ROCKY MOUNTAIN POWER GUIDELINES DO NOT APPLY, THEY ARE NOT THE

PROVIDING UTILITY.

2. SERVICE RISER SHALL INCLUDE AN EXPANSION SLEEVE (SCHEDULE 80) AT

THE BUILDING.

3. ELECTRICAL POWER CONNECTION FEES SHALL BE PAID FOR DIRECTLY BY

THE GOVERNMENT.

4. INSTALL ELECTRICAL AS CALLED FOR. CONCRETE ENCASED ELECTRODE

CONNECTION IS EXISTING BROUGHT UP FROM FOOTING. GFCI

RECEPTACLES ARE NOT ALLOWED AS A SUBSTITUTION FOR GFCI

BREAKERS.

DOOR OPERATORS

5. INSTALL TWO ROLLUP DOOR OPERATORS. SIZE OPERATORS FOR THE TYPE,

SIZE AND WEIGHT OF THE EXISTING NORTH AND SOUTH ROLLUP DOORS,

EITHER 120 OR 240 VAC SINGLE PHASE. INSTALL EACH WITH AN INDIVIDUAL

CIRCUIT INCLUDING PROPER BREAKER. ROLLUP DOOR OPENER SHALL

INCLUDE HARDWIRED OPEN/CLOSE/ STOP 3 BUTTON CONTROL MOUNTED

ON EAST SIDE OF DOOR, SAFETY CONTROLS, INCLUDING REVERSING IF AN

OBSTACLE IS ENCOUNTERED.

HEATING SYSTEM

6. INSTALL HEATING SYSTEM WITH GAS LINE AND EQUIPMENT TO BUILDING AS

DESCRIBED ON SHEET M100.

NEW ELECTRICAL

SERVICE LATERAL

G G

G

NEW GAS SERVICE LATERAL N.I.C.

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text V

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

AutoCAD SHX Text

14'-0"

3'-0"

30'-0"

RECEPTACLE FLOOR PLAN

FIRE ENGINE BUILDING EAST ELEVATION

FIRE ENGINE BUILDING NORTH ELEVATION FIRE ENGINE BUILDING SOUTH ELEVATION

LUMINAIRE HEIGHT MAY BE

ADJUSTED TO AVOID ROLL UP

DOOR INTERIOR MECHANISMS.

LUMINAIRE HEIGHT MAY BE

ADJUSTED TO AVOID ROLL UP

DOOR INTERIOR MECHANISMS.

LUMINAIRE

M

P A

N E

L

A

COMBINATION METER

PANELBOARD

LIGHTING FLOOR PLAN

J

J

B b

B c

C

S c

S b

WORK AREA

ICE MACHINE

A a

A a

A a

A a

A a

A a

A a

A a

A a

KEYNOTES

SEE ELEVATIONS FOR MOUNTING HEIGHT, THE

PERSONNEL DOOR LUMINAIRE IS A SECURITY LIGHT

ONLY CONTROLLED BY THE BUILT IN

PHOTOCONTROLLER

CHAIN SUSPENSION MOUNT AT 12 FEET ABOVE

FINISHED FLOOR, SUSPENSION ATTACHMENT POINT

MAY NEED TO BE ADJUSTED FOR SOUTH LUMINAIRE DO

TO UNIT HEATER.

WIRING TROUGH PROVIDED FOR FUTURE EXPANSION,

SHALL INCLUDE AT LEAST ONE 2-INCH NIPPLE FROM

COMBINATION PANELBOARD

SURFACE MOUNTING MAY REQUIRE MOVING THE

FIXTURE EAST OR WEST TO BE ON A BEAM

AT ROLL UP DOOR MOTOR AT TOP OF OPENING (SIDE

MAY REVERSE) WITH FLEXIBLE CONNECTION TO MOTOR

CONTROLS NEAR LIGHT SWITCH ON EAST SIDE OF ROLL

UP DOOR

SEE MECHANICAL PLANS FOR HEATING OPTION POWER

CONNECTIONS

C

S a

S

3 a

S

3 a

J

M

P A

N E

L

A

A-1

A-1

A-3

A-9

A-5A-5

A-7

A-7

A-9

A-2

DRAWN

DESIGNER

STAMPS, LOGOS, AND SEALS

PROJECT NAME

DRAWING TITLE

CHECKED

ARCHIVE NO.

DATE

PROJECT NO.

DRAWING SHEET NO.

DATENO.

REVISION / ISSUE

OFSHEET

United States Department of Agriculture Forest Service

/30

/24

:5 0 J

AR

EN

MC

CO

UR

T C :\U

SE

RS

\JA

RE

NM

CC

OU

RT

\B

OX

\E

NG

DE

SI

GN

\M

AN

TI

LA

SA

L\

PR

IC

E.

YA

RD

.F

IR

EE

NG

IN

EB

UI

LD

IN

G.

\D W

G\

DR

AW

IN

GS

.E

LE

C_

RE

V1

.D W

G

R-4

INTERMOUNTAIN REGION

PRICE YARD

STORAGE:

ELECTRICAL

MANTI-LASAL NATIONAL

FOREST

PRICE RANGER DISTRICT

ELECTRICAL FLOOR

PLAN

10/05/2021

S.BROWN

S.BROWN

D.JEPPSEN

E200 003 004

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text V

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

FIRE ENGINE BUILDING FLOOR PLAN

UH

T

S

L

G G

G

GAS METER BY OTHERS, N.I.C.

LOCATION MAY VARY

UNIT HEATER SCHEDULE

4 OZ 30x18x28 90115/1MODINE EFFINITY

PTC 55

ONE-STAGE THERMOSTAT (SEE OPERATIONAL REQUIREMENTS), DISCONNECT MAY BE UNIT MOUNTED, HORIZONTAL CONCENTRIC VENT, CONDENSATE DRAIN. MOUNT 14' ABOVE FINISHED FLOOR. USE UNISTRUT

TO SPAN BETWEEN BEAMS FOR HEATER SUPPORT.

FUEL

MANUFACTURER

& MODEL #MARK

HEATING

DIMENSIONS

(W"xH"xD")VOLTS/

PH

REMARKS

UH

1 NG1097

CFM

55 51

INPUT

BTU

INPUT

BTU

FUEL

PRESS.

H.P.

1/8

ELECTRICAL

WT

(LBS)

THERMOSTAT

CONTROLS @48" A.F.F.

UNIT HEATER

DISCONNECT

UNIT HEATER MANUFACTURERS

SCREENED/CAPPED CONCENTRIC VENT FOR

INTAKE AIR AND EXHAUST THROUGH

EXTERIOR WALL.

GAS LINE SIZE PER HEATER

MFG REQUIREMENTS

GENERAL MECHANICAL NOTES

1. THE CONTRACTOR WILL COORDINATE WITH THE

UTILITY COMPANY FOR CONNECTION TO A NEW GAS

SERVICE LATERAL TO THE BUILDING WITH METER.

2. THE DESIGN LAYOUT IS AS A GENERAL PROPOSED

MECHANICAL SYSTEM. GAS LINE AND DUCT SIZING

IS THE RESPONSIBILITY OF THE CONTRACTOR.

3. SOLID MOUNT UNIT HEATER AT 12 FOOT ABOVE

FINISHED FLOOR TO TOP OF UNIT.

4. ELECTRICAL CIRCUIT SHALL BE INCLUDE A 15 AMP

SINGLE POLE BREAKER (120VAC), SIZE 0.5 CONDUIT,

2#14 AND 1#14 GROUND.

5. THERMOSTAT/CONTROL CABLE SHALL BE TYPE TC,

SUNLIGHT RESISTANT AND PROTECTED FROM

DAMAGE TO 8FEET ABOVE FINISHED FLOOR. PVC

SLEEVING ALLOWED.

OPERATIONAL REQUIREMENTS

THERMOSTAT CONTROLS FOR UNIT HEATER SHALL BE SET

FOR 40°F FOR NORMAL OPERATION.

OCCUPANT MAY OVERRIDE TEMPERATURE TO 68°F FOR

USER SELECTABLE 1 TO 8 HOURS IN A MAXIMUM OF HOUR

INCREMENTS UP THROUGH 4 HOURS.

M

P A

N E

L

A

DRAWN

DESIGNER

STAMPS, LOGOS, AND SEALS

PROJECT NAME

DRAWING TITLE

CHECKED

ARCHIVE NO.

DATE

PROJECT NO.

DRAWING SHEET NO.

DATENO.

REVISION / ISSUE

OFSHEET

United States Department of Agriculture Forest Service

/30

/24

:5 0 J

AR

EN

MC

CO

UR

T C :\U

SE

RS

\JA

RE

NM

CC

OU

RT

\B

OX

\E

NG

DE

SI

GN

\M

AN

TI

LA

SA

L\

PR

IC

E.

YA

RD

.F

IR

EE

NG

IN

EB

UI

LD

IN

G.

\D W

G\

DR

AW

IN

GS

.E

LE

C_

RE

V1

.D W

G

R-4

INTERMOUNTAIN REGION

PRICE YARD

STORAGE:

ELECTRICAL

MANTI-LASAL NATIONAL

FOREST

PRICE RANGER DISTRICT

HEATING SYSTEM

10/05/2021

S.BROWN

S.BROWN

D.JEPPSEN

M100 004 004

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text V

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

Sheets and Views
Drawings.Elec_Rev1-General
Drawings.Elec_Rev1-Elect FP
Drawings.Elec_Rev1-MechFP
PriceFSElecDwgsFinalSigned.pdf
Sheets and Views
Coversheet_Elec-Cover
Drawings.Elec-General
Drawings.Elec-Elect FP
Drawings.Elec-MechFP
PriceFSElecDwgsFinalSigned_Rev1.pdf
Sheets and Views
Coversheet_Elec-Cover
Drawings.Elec-General
Drawings.Elec-Elect FP
Drawings.Elec-MechFP

File details come from the government source that posted it. Updated .