This document appears to be a set of schematic plans for the rehabilitation of the Green Knob Fire Tower in the Pisgah National Forest, Appalachian Ranger District. The plans detail the required repairs and security improvements, including installing new bracing, replacing windows and the door, and adding galvanized chain-link security panels. The plans also specify replacing trim and sills with cellular PVC, painting the building, deck, and railings, and removing and replacing the existing exterior door.

The associated federal contract opportunity, Solicitation Number 12445224R0018, is a request for proposals for the Green Knob Fire Tower Rehab project. The contractor shall provide all labor, materials, equipment, and other incidentals necessary to perform the work as outlined in the Statement of Work and the attached schematic plans. A site visit is scheduled for April 26, 2024, and questions are due by April 30, 2024. The project is historical in nature and requires specific experience, which must be submitted on the provided Construction Experience Data Sheet.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CROATAN NF

PISGAH N.F.

NANTAHALA NF

ASHEVILLE

UWHARRIE NF

GRANDFATHER RD

CHARLOTTE

WINSTON-SALEM

RALEIGH

GREENSBORO 17

- STATE MAP -

HICKORY

MORGANTON

ROBBINSVILLE

PROJECT SITE

PISGAH N.F.

NO. DATEBYREVISION DESCRIPTION

SHEET NO.

DATE: 02/16/2024

NATIONAL FORESTS IN NORTH CAROLINA

GREEN KNOB FIRE TOWER REHABILITATION

SCHEMATIC PLANS FOR

U.S. DEPARTMENT OF AGRICULTURE

FOREST SERVICE

REGION EIGHT

PISGAH NATIONAL FOREST

APPALACHIAN RANGER DISTRICT

SHEET INDEX

TITLE SHEET

APPROVED BY:

RECOMMENDED BY:

FOREST SUPERVISOR

NATIONAL FORESTS IN NC

DATE

APPROVED BY:

FOREST ENGINEER

NATIONAL FORESTS IN NC

DATE

DISTRICT RANGER

APPALACHIAN RANGER DISTRICT

SHEET 1

C-01 SHEET 2

AutoCAD SHX Text C:\Users\TimothyHeim\Box\SO~EngHeritageRec~Engineering\From K\Infra\Projects\2300_recreation\01_PROJECTS\Appalachian\2024_GreenKnobRehab\1_Development\Design_CAD\C-00-TITLE-NFsNC Green Knob Fire Tower Rehab.dwg

AutoCAD SHX Text

GREEN KNOB FIRE TOWER

DRAWN

DESIGNER

STAMPS, LOGOS, AND SEALS

PROJECT NAME

DRAWING TITLE

CHECKED

ARCHIVE NO.DATE

PROJECT NO.

DRAWING SHEET NO.

DATENO.

REVISION / ISSUE

OFSHEET

United States Department of Agriculture Forest Service

2/1 2/2

4 1 6:

T

IM

OT

HY

HE

IM

C

:\U

SE

RS

\T

IM

OT

HY

HE

IM

\B

OX

\S

O~

EN

GH

ER

IT

AG

ER

EC

~E

NG

IN

EE

RI

NG

\F

RO

M K\

IN

FR

A\

PR

OJ

EC

TS

\23

_R

EC

RE

AT

IO

N\

_P

RO

JE

CT

S\

AP

PA

LA

CH

IA

N\

_G

RE

EN

KN

OB

RE

HA

B\ 1_

DE

VE

LO

PM

EN

T\

DE

SI

GN

_C

AD

\C

-0 1-

C-

F

SN

C

GR

EE

N

KN

OB

F

IR

E

TO

W

ER

R

EH

AB

.D

W G;

(R08)

SOUTHERN

GREEN KNOB

FIRE TOWER

REHABILITATION

& SECURITY

IMPROVEMENT

PISGAH NATIONAL

FOREST

APPALACHIAN RANGER DISTRICT

REPAIR AND SECURITY

IMPROVEMENT PLAN

02/15/2024

T.HEIM

T.HEIM

C.DAVIS

C-01 002 002

INSTALL NEW P.T. 4IN.x 4IN. BRACING

TO MATCH EXIST.

INSTALL GALV. CHAIN-LINK SECURITY PANEL

SECURED TO UNDERSIDE OF WOOD BRACES

REPLACE DOOR & HARDWARE

APPROX. 36-IN. X 79-IN.

REPLACE ALL 15 WINDOWS, TRIM

& FLASHING PER DETAILS (TYP.)

APPROX. 36-IN. X 48-IN. EA.

INSTALL NEW WOOD BRACING

& GALV. CHAIN-LINK SECURITY PANEL

PLAN VIEW

1" = 4'

SOUTH ELEV.

1" = 4'

EX

. A

C C

ES

S

H

AT

C H

REPLACEMENT WINDOW SECTION

NTS

PROVIDE GLAZING SEALANT ALL EDGES

INSTALL PAINTED ALUMINUM PAN

FLASHING WITH DRIP EDGE.

PROVIDE CAULKING AROUND

FULL PERIMETER OF CASING

REMOVE AND REPLACE APPROX. 8 LF 2x4 TOP RAIL...

3' -1

2'-2"

4' -1

0" 5'

-9

4' -5

2'-3"

PROPOSED POWDER COATED

WINDOW FRAMING, MATCH

EXISTING PROFILE AND COLOR.

1/4" LEXAN PANE GLAZING

REPLACE ALL TRIM AND SILLS

WITH SOLID CELLULAR PVC (TYP.)

SLOPE INTERIOR AND

EXTERIOR SILLS TO DRAIN

SECURITY PANEL FASTENING DETAIL – PLAN VIEW

NTS

SECURITY PANEL FASTENING DETAIL

NTS

CHAIN-LINK FENCING

TENSION BAR (TYP.)

¼-IN. HOOK BOLTS W/FLAT

& LOCK WASHERS (TYP.)

TENSION BAR

REINFORCING WIRE

WIRE TWIST ENLARGEMENT

NEW ¼-IN. GALV. BOLTS. FLAT

WASHERS & LOCK WASHERS (TYP.)

PROVIDE NEW GALV. ANGLES

BOLT TO EXIST. POSTS &

PAINT TO MATCH (TYP.)

REPLACE ALL TRIM AND SILLS

WITH SOLID CELLULAR PVC (TYP.)

REPLACE ALL 15 WINDOWS, TRIM

& FLASHING PER DETAILS (TYP.)

APPROX. 36-IN. X 48-IN. EA.

(BID ALTERNATE)

REMOVE AND REPLACE EXIST. DOOR. NEW DOOR SHALL BE

EXTERIOR GRADE STEEL CLAD FOAM CORE, WITH A 1/4” UV RESISTANT

LEXAN POLYCARBONATE WINDOW WITH TRIM AND MULLIONS APPROPRIATE

MATCH TO EXISTING WINDOWS PROFILES

DRILL HOLES AS NECESSARY & PAINT TO MATCH PRIOR

TO INSTALLATION.

7 GA. VINYL COATED STEEL WIRE TWIST 24-IN. O.C. TOP &

BOTTOM - TWIST ENDS ON OUTSIDE (TYP.)

CLEAN, PREP AND PAINT BUILDING, DECK

AND RAILINGS. (BID ALTERNATE)

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text V

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

AutoCAD SHX Text E

C-00-TITLE-NFsNC Green Knob Fire Tower Rehab
Sheets and Views
11x17
C-01 FsNC Green Knob Fire Tower Rehab
Sheets and Views
C-01
OLE1

File details come from the government source that posted it. Updated .