Attach. 3.1 B710 FOCUS Floor Plans.pdf

PDF 680 KB Posted

Attached to
B710 Architect Design Repair Emergency Services
Solicitation number
FA663326QA004
Issued by

About this file

This document is a facility floor plan for Building 710, an Aerial Port Training Facility located at Minneapolis-St. Paul Air Reserve Station in Minnesota. The document consists of two sheets showing the layout of Floor 1 and Floor 2, each with detailed room designations and square footage measurements.

Floor 1 contains 12,303 User NSF (Net Square Feet) across multiple functional areas including three Aerial Delivery spaces (100-1, 100-2, and 113-1 totaling 5,942 SF), Equipment Staging (107-1, 1,918 SF), a Main Entry (106-1, 171 SF), mechanical and restroom facilities, stairwells, and administrative spaces such as a Command Center, First Sergeant office, and various support areas. The total NSF for Floor 1 is 12,303 SF with an overall facility NSF of 17,379 SF. Floor 2 contains 5,076 User NSF with specialized operational spaces including an Alternate EOC (551 SF), Aircrew Training Ops Center (ATOC, 388 SF), training room (401 SF), flight operations areas, equipment and supply storage, and additional Aerial Delivery space (223-1, 164 SF). The facility has a High Bay height of 20 feet and an approximate wall thickness of 2.032 feet. Total Facility Gross Square Footage is 22,686 GSF with Real Property GSF of 20,493.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

114-1 Aerial Delivery

3201 SF

112-1

JC

53 SF

103-1

CSS

211 SF

108-1 Hall

275 SF

100-3 Stairs

21 SF

113-1 Aerial Delivery

2302 SF

110-1 Mech

131 SF

105-1 Supt

131 SF

122-1 Aerial Delivery

96 SF

107-1 Equip Staging

1918 SF

119-1

RR

191 SF

106-1 Main Entry

171 SF

103-2 Hall

121 SF

109-1

1st Sgt

137 SF

100-2 Aerial Delivery

1933 SF

104-1

ATSEV

112 SF

117-2 Sec Mgr

70 SF

101-1 Stairs

83 SF

121-1 Aerial Delivery

110 SF

114-2 Stairs

159 SF

102-1

CC

132 SF

100-1 Aerial Delivery

1707 SF

118-1

RR

198 SF

113-3 Hall

154 SF

100-4 Stairs

23 SF

111-1 Stairs

133 SF

117-1

UDM

70 SF

113-2 Stairs

23 SF

115-1 Mech

24 SF

116-1 Break Rm

173 SF

High Bay = 20 ft

Ü

Minneapolis-St. Paul ARS, MN

0 7 14 Feet

Floor: Sheet: of1 1 2

Date: 7/22/2020

212-1 Mech

142 SF

205-2 Load Planning

353 SF

224-1 Aerial Delivery

71 SF

204-1 Alt EOC

551 SF

213-1 Stairs

133 SF

221-1 Equip & Supplies

125 SF

215-1

PAX

172 SF

205A-2 Load Planning

44 SF

200-1

ATOC

388 SF

226-1 Mobility Stge

233 SF

203-1

APOS

122 SF

206-1 Flt CC

163 SF

211-1 Hall

69 SF

230-1 Stairs

21 SF

228-1 Stairs

37 SF

217-1 Sect Ch

221 SF

205A-1 Special Handling

44 SF

219-1 Fleet

89 SF

209-1 Trng Rm

401 SF

207-1 Ops O

168 SF

216-1 Cargo

154 SF

227-1 Hall

153 SF

218-1 Special Programs

297 SF

220-1 Stairs

120 SF

223-1 Aerial Delivery

164 SF

229-1 Stairs

13 SF

205-1 Special Handling

270 SF

202-1 Hall

745 SF

222-1 Equip & Supplies

259 SF

208-1 Hall

62 SF

210-1 Ramp

152 SF

201-1 Supt

126 SF

225-1 Mobility Stge

371 SF

214-1

MHE

138 SF

Ü

Minneapolis-St. Paul ARS, MN

0 6.5 13 Feet

Floor: Sheet: of2 2 2

Date: 7/22/2020

File details come from the government source that posted it. Updated .