About this file
This is a Salient Characteristics & Pricing Schedule for a federal contract opportunity at Fairchild Air Force Base, Washington. The 92 Civil Engineering Squadron (92 CES) requires supplies to repair and upgrade a transformer in the Structures Shop, with the objective of providing a stable and robust power supply capable of handling high-draw equipment to ensure mission readiness and prevent damage to critical tools and infrastructure.
The contract requires twelve line items of electrical and structural components to be provided as brand name or equal in salient characteristics. Items include EMT conduit and fittings (elbows, couplings, connectors, and 10-foot lengths of steel conduit), a 36"x36"x14" NEMA 3R enclosure with screw cover, deep strut support materials with elongated holes, threaded rod and end angles, mechanical lugs for conductors, universal strut straps, and 1,280 units of 400 MCM THHN/THWN-2 stranded copper wire in black (2,500-foot spool). Unit prices and total cost columns are provided in the pricing schedule but are blank, indicating this is a template for contractor response. The document is dated April 2026 and specifies delivery to Fairchild AFB, WA.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 26QA243 Amendment 0001.pdf | ||
| Attach. 1 – Salient Characteristics and Pricing Schedule Rev 01.pdf | ||
| Attach. 2 – Air Force Specific Terms and Conditions.pdf | ||
| 26QA243 Combo.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SALIENT CHARACTERISTICS & PRICING SCHEDULE
FOR
Transformer Upgrade Supplies
April 2026
Salient Characteristics & Pricing Schedule For
Transformer Upgrade Supplies
Fairchild AFB, WA
1. BACKGROUND:
The 92 CES requires supplies to repair and upgrade the transformer in the Structures Shop.
2. OBJECTIVES:
Upgrading the transformer will provide the 92 CE Structures shop with a stable and robust power supply, capable of handling high-draw equipment. This ensures mission readiness and prevents damage to critical tools and infrastructure
3. REQUIREMENTS:
Contractor shall provide and deliver the parts listed below as Brand Name or Equal in salient characteristics.
4. PARTS LIST:
ITEM
PART
NUMBER or
EQUAL
DESCRIPTION or EQUAL QTY Unit Unit $ Total $
1 980020020304 4”EMT 90 Degree Elbow 2 Ea 2 784564104694 4” EMT Set Screw Coupling 10 Ea 3 783510145170 36”x36”x14” Nema 3R
Enclosure, screw cover 1 Ea
4 980010020109 4” EMT Conduit, Steel, 10’ length
100 Ea
5 702316501027 Deep strut, elongated holes, steel pre-galvanized, 1-5/8”x1- 5/8”x10’
20 Ea
6 702316501164 Two Hole End angle, steel electro-galvanized, 9/16”, 8 bolt
8 Ea
7 702316528925 All Threaded rod, Zinc-plated, 3/8”x10’
20 Ea
8 784564104595 4” EMT Set Screw Connector 4 Ea 9 980010001108 4” Rigid Steel Conduit, 10’ length 20 Ea
10 783669005684 Mechanical Lug, 1-hole, 2 conductor, 2AWG-600 MCM, ½” stud size, aluminum
4 Ea
11 616013140819 Universal Strut Strap, 4”, Hot dipped, galvanized
10 Ea
12 048243539062 400 MCM THHN/THWN-2
Stranded Copper, Black 2500'
1280 Ea