Attach 2_Sasebo Price Schedule.xlsx

XLSX spreadsheet 23 KB Posted

Attached to
25R10 Sasebo Hazardous Waste Removal and Disposal
Solicitation number
SP450025R0010
Issued by

About this file

This is a price schedule template for hazardous waste disposal services at Base Sasebo, Japan. The schedule lists detailed line items for various waste management services including tank cleaning (ranging from 1,000 to 21,000 gallon capacities), transportation services, and disposal of numerous hazardous materials including: various types of batteries (alkaline, lithium, lead acid, etc.), acids, AFFF fire-fighting foam containing PFOA/PFOS, fluorescent lamps, mercury waste, used oil, asbestos materials, and reactive chemicals. The schedule includes specific quantity estimates for each waste stream, with major items including 50,110 lbs of oil filters, 38,165 lbs of friable asbestos, 22,740 lbs of fluorescent lamps, and 66,300 lbs of AFFF concentrate liquid.

The price schedule is part of solicitation SP450025R0010 for a 30-month base contract (October 2025 to November 2027) with a 30-month option period (November 2027 to May 2030). The Defense Logistics Agency is seeking these services under full and open competition with NAICS code 562211 and a $47M small business size standard. Proposals are due by 1500 EST on March 6, 2025, and should be submitted via email to specified DLA contracting officers.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Base

Sasebo HW Disposal - Price Schedule, Base
HINHIN DescriptionUoMEstimated QuantityPriceExtended Cost
6350AATank cleaning/services - above ground, up to 1,000 GL capacity. (See 3.3)EA7$ - 0
6350BBTank cleaning/cervices – above ground, 1,001 to 3,000 GL capacity. (See 3.3)EA5$ - 0
6350CCTank cleaning/services – above ground, 3,001 to 6,000 GL capacity. (See 3.3)EA5$ - 0
6350EETank cleaning/services – above ground, 6,001 to 12,000 GL capacity. (See 3.3)EA3$ - 0
6350FFTank cleaning/services – above ground, 12,001 to 21,000 GL capacity. (See 3.3)EA3$ - 0
6394SATransportation Returned Waste (See 3.3)EA3$ - 0
6395SATransportation Fee - Kanoya (See 3.1).EA3$ - 0
BA01C7Sludge, Alkaline Batteries, may be managed as IW/Regulated, for Recycling or Disposal. (See 1.2.8.2(h))LB22,000$ - 0
BA02C7Sludge, Calcium Chromate (CaCrO4) Thermal Batteries, Deactivated, may be managed as IW/Regulated, for Recycling or Disposal.LB2,500$ - 0
BA03C7Sludge, Carbon-Zinc (CZn) Batteries, Zinc Air, may be managed as IW/Regulated, for Recycling or Disposal.LB50$ - 0
BA04C7Sludge, Lead Acid Batteries, Wet, Dry or Gel Pack may be managed as IW/Regulated, for Recycling/Recovery Only.LB9,000$ - 0
BA05C7Sludge, Lithium Ion (Li-Ion) Batteries, may be managed as IW/Regulated, for Recycling or Disposal.LB1,265$ - 0
BA06C7Sludge, Lithium Iron Disulfide (Li2FeS2) Thermal Batteries, including fully discharged Lithium Alloy Thermal Batteries, Deactivated, may be managed as IW/Regulated, for Recycling or Disposal.LB50$ - 0
BA07C7Sludge, Lithium Manganese (LiMn and Oxides thereof) Batteries, may be managed as IW/Regulated, for Recycling or Disposal.LB50$ - 0
BA08C7Sludge, Lithium Sulfur Dioxide (LiSO2) Batteries, may be managed as IW/Regulated, for Recycling or Disposal.LB185$ - 0
BA10C7Sludge, Lithium Batteries, Mixed Types, Deactivated if Applicable, may be managed as IW/Regulated, for Recycling or Disposal.LB550$ - 0
BA12C7Sludge, Mercury (Hg) Batteries, may be managed as Regulated, for Recycling or Disposal.LB130$ - 0
BA13C7Sludge, Nickel Metal Hydride (NiMh) Batteries, Wet and Dry may be managed as IW/regulated, for Recycling/Recovery Only.LB50$ - 0
BA14C7Sludge, Nickel-Cadmium (NiCd) Batteries, Wet and Dry, may be managed as IW/regulated, for Recycling/Recovery Only.LB5,170$ - 0
CS01C7Waste Acids, Organic or Inorganic, other than HF and HNO3, pH 2.1 - 6.9, No Heavy Metals, Managed as IW.LB9,150$ - 0
CS02C7Waste Acids, Organic or Inorganic other than HF and HNO3, pH <7.0, May contain JEGS or GOJ waste codes, Managed as Regulated.LB250$ - 0
CS03C7Waste Acids, Corrosive Acids, Organic or Inorganic other than HF and HNO3, Concentrated, pH≤2.0,
May contain JEGS or GOJ waste codes. Managed as Regulated.LB2,100$ - 0
CS08C7Waste Acids, Non-Fuming, Hydrofluoric (HF) <40% and Nitric (HNO3), <25% in Water. Includes Inorganic acids. Managed as IW.LB250$ - 0
CS10C7Waste Alkaline, Organic or Inorganic, pH 7.1 - 12.4, No heavy metals. No Ammonia/Amines. Managed as IW.LB40,300$ - 0
CS11C7Waste Alkalines, Organic or Inorganic, May contain JEGS or GOJ Regulated Materials, pH >7.0. No Ammonia/Amines. Managed as Regulated.LB20,330$ - 0
CS12C7Waste Corrosive Ammonia/Amines, Organic/Inorganic, Liquids/Sludges/Solids/Debris, Flashpoint ≥158◦F. Managed as Regulated.LB200$ - 0
CS14C7Waste Corrosive Inorganic Acids or Bases with Debris and Free Liquids, No Ammonia/Amines, Non-Flammable, including broken lead acid batteries.LB400$ - 0
CY08C7Cylinders, Propane, Camping Physical State: Comp. Gas Permissible Waste Codes: As Appropriate to Each Gas. (See 2.6).LB300$ - 0
CY09C7Cylinders, Acetylene, including Empty cylinders Containing Asbestos.(See 2.6).LB450$ - 0
CY12C7Cartridges, Flammable Gas, AVGAS, Gas/Diesel Starting, for Disposal/Recycle. Diameter up to 3", Length up to 12". (See 2.6).LB45$ - 0
CY40C7Compressed gas cylinders, Inert, Graded Breathing Air, Non-Flammable Gases, May include fire extinguishers, No Halon. (See 2.6).LB5,000$ - 0
CY41C7Compressed gas cylinders, including cartridges, Flammable gases, Managed as Regulated. (See 2.6).LB530$ - 0
CY44C7Ozone Depleting Substances, JEGS or GOJ designated hazardous substances, Halon. Managed as Regulated. (See 2.6).LB4,606$ - 0
FL01C7Waste, Oil, Aerosols, Flammable/Combustible/Ignitable, Non-foaming, No isocyanates, reactives, or corrosives, may include JEGS or GOJ designated hazardous substances. Managed as IW/Regulated.LB23,800$ - 0
FL02C7Sludge, Industrial Waste, Flammable Debris, Contaminated with Common Solvents, Shreddable, e.g., absorbents, rags, PCP wood. No Free Liquids, No large metal, rock, No containers, or masonry components; Managed as IW/Regulated.LB450$ - 0
FL03C7Industrial Waste, Flammable, Liquids/Solids/Sludges/Debris, e.g., tank sludge, absorbents, lubricants, adhesives, rags, filters, PPE, miscellaneous debris, non-reactive paint waste with isocyanates, Primarily consists of incinerable, combustible material. Managed as IW/Regulated.LB1,500,000$ - 0
FL12C7Sludge, Flammable Solids/Sludges, Highly Chlorinated (>10%), solvents, Insecticides, Herbicides, and Pesticides. JEGS or GOJ Regulated, No PCBs, Dioxins, Furans, or Precursors. Managed as Regulated.LB250$ - 0
FL99C7Military Items, Demil-Required, Flammable Solids/Liquids/Debris, i.e. CDE Kits, Vials, Filters, PPE, etc. for Treatment and Disposal. Certificate of Disposal/Destruction Required.LB200$ - 0
NR90C7AFFF-Contaminated Solids/Sludges/Debris for Incineration, e.g., Soil, gravel, PPE, Filter Media. May contain some free liquids. Containing PFOA/PFOS. No empty containers. Certificate of Disposal/Destruction Required. Formerly NR91C7.LB8,530$ - 0
NR93B5AFFF Rinsates and other impacted waters for Incineration, Pumpable, Used or >90% water by volume. Containing PFOA/PFOS. Bulk removals may be from storage tanks, totes, containments, storm sewer, ground and surface waters. Certificate of Disposal/Destruction Required.GL5,000$ - 0
NR93C7AFFF Concentrate Liquid for Incineration, Unused or >10% AFFF Product, Pumpable. Containing PFOA/PFOS. GOJ Regulated. Certificate of Disposal/Destruction Required.LB66,300$ - 0
NR94B5AFFF Rinsates and other impacted waters for Incineration, Pumpable, Used or >90% water by volume. Containing PFOA/PFOS. Bulk removals may be from storage tanks, totes, containments, storm sewer, ground and surface waters. Certificate of Disposal/Destruction Required.GL5,000$ - 0
NR94C7AFFF Rinsates and other impacted waters for Incineration. Used or >90% water by volume. Containing PFOA/PFOS. Bulk removals may be from storage tanks, totes, containments, storm sewer, ground and surface waters. Certificate of Disposal/Destruction Required.LB4,500$ - 0
NR97C7Non-Regulated Solids/Sludges/Debris, for Incineration. May contain some free liquids. Not used for AFFF or other PFAS-related wastes. No empty containers, No Fire Extinguishers. CD required.LB15,000$ - 0
NR98C7Non-Regulated Military Articles, Demil-Required, i.e. Boots, Gloves, CDE Kits, Filters, Masks, MOPP Suits, etc. for incineration. Certificate of Disposal/Destruction Required. No Uniforms or submarine tiles.LB2,685$ - 0
RE01C7Sludge, Lamps, Fluorescent, Intact, Linear, CFLs, U-Bent, and Circulars. Managed as Regulated.LB22,740$ - 0
RE02C7Sludge, Lamps, Fluorescent, Crushed/Broken Lamps, may contain Filters and some debris.LB465$ - 0
RE05C7Sludge, Lamps, Mercury/Mercury Vapor (May include broken lamps).LB335$ - 0
RE09C7Sludge, Mercury, High, Liquid Mercury/Devices, Debris & Residues, Hg >1000 mg/Kg, i.e. Elemental Mercury Only. Managed as SHIW For Mandatory Recycling.LB15$ - 0
RE10C7Waste Oil, Antifreeze, Used and Unused for Recycling or Energy recovery.LB14,065$ - 0
RE13C7Used Oil Filters, Drained and Undrained, and/Fully Drained Fuel Filters.LB50,110$ - 0
RG01C7Waste Dispersible/Friable Asbestos, Building Maintenance ACM, GOJ Regulated, Generator Special Packaging Required. No Free Liquids. (See 2.4).LB38,165$ - 0
RG02C7Waste Non-Dispersible/Non-Friable Asbestos, Building Maintenance ACM, GOJ Regulated, Generator Special Packaging Required. No Free Liquids. (See 2.4).LB1,695$ - 0
RX06C7Sludge, Reactive Oxidizers, e.g., Nitrates, Nitrites, Persulfates, Inorganic Peroxides only.LB350$ - 0
RX08C7Sludge, Reactive Metals, e.g., Powders, Dusts, Fines. Air/Water Reactive. Shipped Under Oil and/or other Generator Required Special Packaging.LB3,150$ - 0
RX09C7Reactive Metals, Debris. Air/Water Reactive. Shipped Under Oil and/or other Generator Required Special Packaging. No burnt (burned) batteries.LB50$ - 0
RX10C7Sludge, Reactive Non-Metals, e.g., P-Coded, Temperature Sensitive, Poison Inhalation Hazards (PIHs), Air/Water Reactive. Generator special packaging may be required. Pyrophoric Metals, Spontaneous ignite when exposed to air, ex: T-Buli, Potassium Hydrida (KH), and white phosphoric Iron (Fes).LB50$ - 0
RX40C7Sludge, Liquids, Organic/Inorganic Peroxides. Managed as Regulated.LB155$ - 0
RX95C7Sludge, Reactive, Ignitable, and Toxic Solids, e.g., tank bottoms, sludge, and/or debris for Thermal Destruction. Contaminated with Mineral Spirits, Motor Oil, Alcohol, Solvents, and Otto Fuel. <1% Cyanide, <1% Alcohol, <1% Total Metals.LB135$ - 0
RX97C7Sludge, Reactive, Ignitable, and Toxic Liquid for Thermal Destruction. Contains Water, Mineral Spirits, Motor Oil, Alcohol, Solvents, and Otto Fuel. <1% Cyanide, <1% Alcohol, <1% Total Metals.LB150$ - 0
RX98C7Sludge, Oxygen Breathing Apparatus (OBA) Cannisters, Emergency Escape Breathing Device (EEBD) and Oxygen Candles, Potentially Reactive, Spent and/or Unspent. Generator Special packaging may be required.LB4,100$ - 0
TX12C7Sludge, Metals-Bearing Liquids, Low, <1% TCLP Metals or Japanese Leaching Test equivalent, Total Cr+6 <100 ppm, Total Hg <260 ppm.LB275$ - 0
TX20C7Sludge, Metals-Bearing Debris/Solids/Sludges with some Free Liquids, Contains JEGS/GOJ Regulated waste. Characteristic/Listed. Heavy Metals Contaminated Debris, Paint Booth filters, shop cleaning debris, range targets, etc.LB108,400$ - 0
TX22C7Organics in Solids/Sludges/Debris, i.e. soil, tank & still bottoms, some adhesives, filtercake, electro plating related shop waste (sludge). Not more toxic than common solvents. No Hg contaminated waste.LB23,000$ - 0
TX98C7Military Items, Toxic, Demil-required, i.e. CDE Kits, Tents, Filters, PPE, etc. for Treatment and Disposal. Certificate of Disposal/Destruction Required.LB50$ - 0
Total:$ - 0

Option

Sasebo HW Disposal - Price Schedule, Option
HINHIN DescriptionUoMEstimated QuantityPriceExtended Cost
6350AATank cleaning/services - above ground, up to 1,000 GL capacity. (See 3.3)EA7$ - 0
6350BBTank cleaning/cervices – above ground, 1,001 to 3,000 GL capacity. (See 3.3)EA5$ - 0
6350CCTank cleaning/services – above ground, 3,001 to 6,000 GL capacity. (See 3.3)EA5$ - 0
6350EETank cleaning/services – above ground, 6,001 to 12,000 GL capacity. (See 3.3)EA3$ - 0
6350FFTank cleaning/services – above ground, 12,001 to 21,000 GL capacity. (See 3.3)EA3$ - 0
6394SATransportation Returned Waste (See 3.3)EA3$ - 0
6395SATransportation Fee - Kanoya (See 3.1).EA3$ - 0
BA01C7Sludge, Alkaline Batteries, may be managed as IW/Regulated, for Recycling or Disposal. (See 1.2.8.2(h))LB22,000$ - 0
BA02C7Sludge, Calcium Chromate (CaCrO4) Thermal Batteries, Deactivated, may be managed as IW/Regulated, for Recycling or Disposal.LB2,500$ - 0
BA03C7Sludge, Carbon-Zinc (CZn) Batteries, Zinc Air, may be managed as IW/Regulated, for Recycling or Disposal.LB50$ - 0
BA04C7Sludge, Lead Acid Batteries, Wet, Dry or Gel Pack may be managed as IW/Regulated, for Recycling/Recovery Only.LB9,000$ - 0
BA05C7Sludge, Lithium Ion (Li-Ion) Batteries, may be managed as IW/Regulated, for Recycling or Disposal.LB1,265$ - 0
BA06C7Sludge, Lithium Iron Disulfide (Li2FeS2) Thermal Batteries, including fully discharged Lithium Alloy Thermal Batteries, Deactivated, may be managed as IW/Regulated, for Recycling or Disposal.LB50$ - 0
BA07C7Sludge, Lithium Manganese (LiMn and Oxides thereof) Batteries, may be managed as IW/Regulated, for Recycling or Disposal.LB50$ - 0
BA08C7Sludge, Lithium Sulfur Dioxide (LiSO2) Batteries, may be managed as IW/Regulated, for Recycling or Disposal.LB185$ - 0
BA10C7Sludge, Lithium Batteries, Mixed Types, Deactivated if Applicable, may be managed as IW/Regulated, for Recycling or Disposal.LB550$ - 0
BA12C7Sludge, Mercury (Hg) Batteries, may be managed as Regulated, for Recycling or Disposal.LB130$ - 0
BA13C7Sludge, Nickel Metal Hydride (NiMh) Batteries, Wet and Dry may be managed as IW/regulated, for Recycling/Recovery Only.LB50$ - 0
BA14C7Sludge, Nickel-Cadmium (NiCd) Batteries, Wet and Dry, may be managed as IW/regulated, for Recycling/Recovery Only.LB5,170$ - 0
CS01C7Waste Acids, Organic or Inorganic, other than HF and HNO3, pH 2.1 - 6.9, No Heavy Metals, Managed as IW.LB9,150$ - 0
CS02C7Waste Acids, Organic or Inorganic other than HF and HNO3, pH <7.0, May contain JEGS or GOJ waste codes, Managed as Regulated.LB250$ - 0
CS03C7Waste Acids, Corrosive Acids, Organic or Inorganic other than HF and HNO3, Concentrated, pH≤2.0,
May contain JEGS or GOJ waste codes. Managed as Regulated.LB2,100$ - 0
CS08C7Waste Acids, Non-Fuming, Hydrofluoric (HF) <40% and Nitric (HNO3), <25% in Water. Includes Inorganic acids. Managed as IW.LB250$ - 0
CS10C7Waste Alkaline, Organic or Inorganic, pH 7.1 - 12.4, No heavy metals. No Ammonia/Amines. Managed as IW.LB40,300$ - 0
CS11C7Waste Alkalines, Organic or Inorganic, May contain JEGS or GOJ Regulated Materials, pH >7.0. No Ammonia/Amines. Managed as Regulated.LB20,330$ - 0
CS12C7Waste Corrosive Ammonia/Amines, Organic/Inorganic, Liquids/Sludges/Solids/Debris, Flashpoint ≥158◦F. Managed as Regulated.LB200$ - 0
CS14C7Waste Corrosive Inorganic Acids or Bases with Debris and Free Liquids, No Ammonia/Amines, Non-Flammable, including broken lead acid batteries.LB400$ - 0
CY08C7Cylinders, Propane, Camping Physical State: Comp. Gas Permissible Waste Codes: As Appropriate to Each Gas. (See 2.6).LB300$ - 0
CY09C7Cylinders, Acetylene, including Empty cylinders Containing Asbestos.(See 2.6).LB450$ - 0
CY12C7Cartridges, Flammable Gas, AVGAS, Gas/Diesel Starting, for Disposal/Recycle. Diameter up to 3", Length up to 12". (See 2.6).LB45$ - 0
CY40C7Compressed gas cylinders, Inert, Graded Breathing Air, Non-Flammable Gases, May include fire extinguishers, No Halon. (See 2.6).LB5,000$ - 0
CY41C7Compressed gas cylinders, including cartridges, Flammable gases, Managed as Regulated. (See 2.6).LB530$ - 0
CY44C7Ozone Depleting Substances, JEGS or GOJ designated hazardous substances, Halon. Managed as Regulated. (See 2.6).LB4,606$ - 0
FL01C7Waste, Oil, Aerosols, Flammable/Combustible/Ignitable, Non-foaming, No isocyanates, reactives, or corrosives, may include JEGS or GOJ designated hazardous substances. Managed as IW/Regulated.LB23,800$ - 0
FL02C7Sludge, Industrial Waste, Flammable Debris, Contaminated with Common Solvents, Shreddable, e.g., absorbents, rags, PCP wood. No Free Liquids, No large metal, rock, No containers, or masonry components; Managed as IW/Regulated.LB450$ - 0
FL03C7Industrial Waste, Flammable, Liquids/Solids/Sludges/Debris, e.g., tank sludge, absorbents, lubricants, adhesives, rags, filters, PPE, miscellaneous debris, non-reactive paint waste with isocyanates, Primarily consists of incinerable, combustible material. Managed as IW/Regulated.LB1,500,000$ - 0
FL12C7Sludge, Flammable Solids/Sludges, Highly Chlorinated (>10%), solvents, Insecticides, Herbicides, and Pesticides. JEGS or GOJ Regulated, No PCBs, Dioxins, Furans, or Precursors. Managed as Regulated.LB250$ - 0
FL99C7Military Items, Demil-Required, Flammable Solids/Liquids/Debris, i.e. CDE Kits, Vials, Filters, PPE, etc. for Treatment and Disposal. Certificate of Disposal/Destruction Required.LB200$ - 0
NR90C7AFFF-Contaminated Solids/Sludges/Debris for Incineration, e.g., Soil, gravel, PPE, Filter Media. May contain some free liquids. Containing PFOA/PFOS. No empty containers. Certificate of Disposal/Destruction Required. Formerly NR91C7.LB8,530$ - 0
NR93B5AFFF Rinsates and other impacted waters for Incineration, Pumpable, Used or >90% water by volume. Containing PFOA/PFOS. Bulk removals may be from storage tanks, totes, containments, storm sewer, ground and surface waters. Certificate of Disposal/Destruction Required.GL5,000$ - 0
NR93C7AFFF Concentrate Liquid for Incineration, Unused or >10% AFFF Product, Pumpable. Containing PFOA/PFOS. GOJ Regulated. Certificate of Disposal/Destruction Required.LB66,300$ - 0
NR94B5AFFF Rinsates and other impacted waters for Incineration, Pumpable, Used or >90% water by volume. Containing PFOA/PFOS. Bulk removals may be from storage tanks, totes, containments, storm sewer, ground and surface waters. Certificate of Disposal/Destruction Required.GL5,000$ - 0
NR94C7AFFF Rinsates and other impacted waters for Incineration. Used or >90% water by volume. Containing PFOA/PFOS. Bulk removals may be from storage tanks, totes, containments, storm sewer, ground and surface waters. Certificate of Disposal/Destruction Required.LB4,500$ - 0
NR97C7Non-Regulated Solids/Sludges/Debris, for Incineration. May contain some free liquids. Not used for AFFF or other PFAS-related wastes. No empty containers, No Fire Extinguishers. CD required.LB15,000$ - 0
NR98C7Non-Regulated Military Articles, Demil-Required, i.e. Boots, Gloves, CDE Kits, Filters, Masks, MOPP Suits, etc. for incineration. Certificate of Disposal/Destruction Required. No Uniforms or submarine tiles.LB2,685$ - 0
RE01C7Sludge, Lamps, Fluorescent, Intact, Linear, CFLs, U-Bent, and Circulars. Managed as Regulated.LB22,740$ - 0
RE02C7Sludge, Lamps, Fluorescent, Crushed/Broken Lamps, may contain Filters and some debris.LB465$ - 0
RE05C7Sludge, Lamps, Mercury/Mercury Vapor (May include broken lamps).LB335$ - 0
RE09C7Sludge, Mercury, High, Liquid Mercury/Devices, Debris & Residues, Hg >1000 mg/Kg, i.e. Elemental Mercury Only. Managed as SHIW For Mandatory Recycling.LB15$ - 0
RE10C7Waste Oil, Antifreeze, Used and Unused for Recycling or Energy recovery.LB14,065$ - 0
RE13C7Used Oil Filters, Drained and Undrained, and/Fully Drained Fuel Filters.LB50,110$ - 0
RG01C7Waste Dispersible/Friable Asbestos, Building Maintenance ACM, GOJ Regulated, Generator Special Packaging Required. No Free Liquids. (See 2.4).LB38,165$ - 0
RG02C7Waste Non-Dispersible/Non-Friable Asbestos, Building Maintenance ACM, GOJ Regulated, Generator Special Packaging Required. No Free Liquids. (See 2.4).LB1,695$ - 0
RX06C7Sludge, Reactive Oxidizers, e.g., Nitrates, Nitrites, Persulfates, Inorganic Peroxides only.LB350$ - 0
RX08C7Sludge, Reactive Metals, e.g., Powders, Dusts, Fines. Air/Water Reactive. Shipped Under Oil and/or other Generator Required Special Packaging.LB3,150$ - 0
RX09C7Reactive Metals, Debris. Air/Water Reactive. Shipped Under Oil and/or other Generator Required Special Packaging. No burnt (burned) batteries.LB50$ - 0
RX10C7Sludge, Reactive Non-Metals, e.g., P-Coded, Temperature Sensitive, Poison Inhalation Hazards (PIHs), Air/Water Reactive. Generator special packaging may be required. Pyrophoric Metals, Spontaneous ignite when exposed to air, ex: T-Buli, Potassium Hydrida (KH), and white phosphoric Iron (Fes).LB50$ - 0
RX40C7Sludge, Liquids, Organic/Inorganic Peroxides. Managed as Regulated.LB155$ - 0
RX95C7Sludge, Reactive, Ignitable, and Toxic Solids, e.g., tank bottoms, sludge, and/or debris for Thermal Destruction. Contaminated with Mineral Spirits, Motor Oil, Alcohol, Solvents, and Otto Fuel. <1% Cyanide, <1% Alcohol, <1% Total Metals.LB135$ - 0
RX97C7Sludge, Reactive, Ignitable, and Toxic Liquid for Thermal Destruction. Contains Water, Mineral Spirits, Motor Oil, Alcohol, Solvents, and Otto Fuel. <1% Cyanide, <1% Alcohol, <1% Total Metals.LB150$ - 0
RX98C7Sludge, Oxygen Breathing Apparatus (OBA) Cannisters, Emergency Escape Breathing Device (EEBD) and Oxygen Candles, Potentially Reactive, Spent and/or Unspent. Generator Special packaging may be required.LB4,100$ - 0
TX12C7Sludge, Metals-Bearing Liquids, Low, <1% TCLP Metals or Japanese Leaching Test equivalent, Total Cr+6 <100 ppm, Total Hg <260 ppm.LB275$ - 0
TX20C7Sludge, Metals-Bearing Debris/Solids/Sludges with some Free Liquids, Contains JEGS/GOJ Regulated waste. Characteristic/Listed. Heavy Metals Contaminated Debris, Paint Booth filters, shop cleaning debris, range targets, etc.LB108,400$ - 0
TX22C7Organics in Solids/Sludges/Debris, i.e. soil, tank & still bottoms, some adhesives, filtercake, electro plating related shop waste (sludge). Not more toxic than common solvents. No Hg contaminated waste.LB23,000$ - 0
TX98C7Military Items, Toxic, Demil-required, i.e. CDE Kits, Tents, Filters, PPE, etc. for Treatment and Disposal. Certificate of Disposal/Destruction Required.LB50$ - 0
Total:$ - 0

File details come from the government source that posted it. Updated .