Attach-2-Drawings.pdf
PDF 6 MB Posted
- Attached to
- ARTHUR -DEMO & CONSTRUCT NEW METAL OBSERVATION TOW Federal contract opportunity
- Solicitation number
- 140F0122R0120
About this file
This package includes construction drawings and specifications for a new metal observation tower at the Arthur R. Marshall Loxahatchee National Wildlife Refuge in Boynton Beach, Florida. Key details include demolishing an existing timber walk and observation deck and constructing a new tower structure with transfer level, ramps, landings, and stairs to access two observation floors. The project also involves concrete repairs and application of a polymer sealer to existing concrete pads. Structural steel, aluminum, and galvanized metal materials will be used for erection of the tower, guardrails, and plank grating. Special inspections will be required during welding, bolting, concrete work and installation of post-installed anchors. The response due date is not provided.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Sol_140F0122R0120_Amd_0001.pdf | ||
| Attach-6-Past_Performance__and_Clauses.pdf | ||
| Attach-3-Design_Analysis.pdf | ||
| Sol_140F0122R0120.pdf | ||
| Attach-5-DBA_Min__Wage_Rates.pdf | ||
| Attach-4-Price_Sheet.xlsx | XLSX spreadsheet | |
| Attach-1-SOW.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
F
LO
R
ID
A
L
IC
E N
S E
R
E O
B R
S A
S
IO
N A
N
GIN
E
L E
T S
B A
N o.
ER
PROF ES
S T
A T
E O
F
METRIC CONVERSION TABLES
INCHES
CENTIMETERS
2.54 5.08 7.62 10.16 12.70 15.24 17.78 20.32 22.86
FEET
METERS
0.305 0.610 0.914 1.219 1.524 1.829 2.134 2.438 2.743
MILES
KILOMETERS
1.609 3.219 4.828 6.437 8.047 9.656 11.265 12.875 14.484
CENTIMETERS
METERS
KILOMETERS
INCHES
0.934 0.787 1.181 1.574 1.969 2.362 2.756 3.150 3.543
FEET
3.281 6.562 9.843 13.123 16.404 19.6805 22.966 26.247 29.528
MILES
0.621 1.243 1.864 2.485 3.107 3.728 4.350 4.971 5.592
PROJECT
LOCATION
LOCATION MAP
DRAWN:
CHECK:
SHT. NO.
SHEET TITLE
REV. NO.
DESIGN:
DATE:
COMM NO:
123456
E
D
A
B
C
123456
P e a c h tr e e D u n w o o d y R o a d
B u ild in g C
S u it e
A tl a n ta
G
.3
.1 w ile y w ils o n .c o m
E m p lo y e e -O w n e d
/2
/2
:4
:5
P
M
C U s e rs
\s g e rh a rd t\ D o c u m e n ts
\2
L o x O b T o w e r_
R
C e n S tr u c s g e rh a rd tM J S
D W
.r v t
LEE ROAD - COVER
SHEET
U N
IT
E
D S
T A
T E
S F
IS
H
W
IL
D
L
IF
E S
E R
V
IC
E
RAB
SNG
02/25/2022
220146
G-001
SNG
L E
E R
O A
D S
IT
E
B
O Y
N T
O N
B E
A C
H
F L
O R
ID
A
A R
M L
O X
A H
A T
C H
E E
N A
T
IO
N A
L W
IL
D
L
IF
E R
E F
U G
E
L -4
O
B S
E R
V A
T
IO
N T
O W
E R
CONSTRUCTION DOCUMENTS
FEBRUARY 25, 2022
ARCHITECTURAL GRAPHIC
SCALES
ENGINEERING GRAPHIC
SCALES
32'16'8'0'
SCALE: 1/16"=1'-0"
24'16'8'0'
SCALE: 3/32"=1'-0"
16'8'4'0'
SCALE: 1/8"=1'-0"
12'8'4'0'
SCALE: 3/16"=1'-0"
8'4'2'0'
SCALE: 1/4"=1'-0"
6'4'2'0'
SCALE: 3/8"=1'-0"
4'2'1'0'
SCALE: 1/2"=1'-0"
3'2'1'0'
SCALE: 3/4"=1'-0"
2'1'6"0'
SCALE: 1"=1'-0"
9"6"3"0'
SCALE: 3"=1'-0"
ARM LOXAHATCHEE NATIONAL
WILDLIFE REFUGE
L-40 OBSERVATION TOWER
0 1.3 m 2.5 m 5.0 m
SCALE: 1:100
0 12.5 m 25.0 m 50.0 m
SCALE: 1:1000
0 0.1 m 0.3 m 0.5 m
SCALE: 1:10
BOYNTON BEACH, FLORIDA
SOUTH ATLANTIC-GULF & MISSISSIPPI BASIN REGION
M R
K D
A T
E R
E V
I S
IO
N D
E S
C R
IP
T
IO
N
R
ID
A
L
IC
E N
S E
R
E O
B R
S A
S
IO
N A
N
GIN
E
L E
T S
B A
N o.
ER
PROF ES
S T
A T
E O
F
ABBREVIATIONS
O
OC - ON CENTER
OD - OUTSIDE DIAMETER
OPNG - OPENING
OPP - OPPOSITE
OPH - OPPOSITE HAND
OA - OVERALL
P
PR - PAIR
PSF - POUNDS PER SQUARE FOOT
PNL - PANEL
PL OR ⅊ - PLATE
PREFIN - PREFINISH
PRMLD - PREMOLDED
PART - PARTIAL
R
REINF - REINFORCED
REQ - REQUIRE
REQD - REQUIRED
REFL - REFLECT
REPL - REPLACE
R - RISER/RADIUS
RND - ROUND
RO - ROUGH OPENING
S
SCHED - SCHEDULE
SGL - SINGLE
SECT - SECTION
SHT - SHEET
SIM - SIMILAR
SPEC(S) - SPECIFICATIONS
SF - SQUARE FOOT(FEET)
SQ - SQUARE
SQ IN - SQUARE INCH
ST - STREET, STAIRS
STD - STANDARD
STL - STEEL
STR - STRUCTURAL
SST - STAINLESS STEEL
SUSP - SUSPEND, SUSPENDED
G
GALV - GALVANIZED
GA - GAUGE
GEN - GENERAL
GOV'T - GOVERNMENT
H
HC - HANDICAP
HNDRL - HANDRAIL
HDR - HEADER
HGT - HEIGHT
HORIZ - HORIZONTAL
HR - HOUR
H - HIGH
I
INSTL - INSTALL
INV - INVERT
IBC - INTERNATIONAL BUILDING CODE
J
JT - JOINT
JST - JOIST
L
LRG - LARGE
LT GA - LIGHT GAGE
LOC - LOCATION
M
MFR - MANUFACTURER
MAX - MAXIMUM
MIN - MINIMUM
MISC - MISCELLANEOUS
MTL - METAL
MOD - MODEL, MODIFY
N
N - NORTH
NA - NOT APPLICABLE
NIC - NOT IN CONTRACT
NO - NUMBER
NOM - NOMINAL
NTS - NOT TO SCALE
D
D - DEEP
DBL - DOUBLE
DET - DETAIL
DEG - DEGREE
DEMO - DEMOLITION
DIAG - DIAGONAL
DIM - DIMENSION
DUPL - DUPLICATE
DIST - DISTANCE
DN - DOWN
DS - DOW N SPOUT
DWG - DRAW ING
E
EA - EACH
EW - EACH WAY
EL - ELEVATION
EJ - EXPANSION JOINT
ELEC - ELECTRICAL, ELECTRIC
ENGR - ENGINEER
ENVIR - ENVIRONMENT
EQ - EQUAL
EQUIP - EQUIPMENT
ETC - ETCETERA, AND SO FORTH
EXIST - EXISTING
EXP - EXPANSION, EXPAND
EXT - EXTERIOR
F
FIN FLR - FINISH FLOOR
FF EL - FINISH FLOOR ELEVATION
FSTNR - FASTENER
FT - FEET
FRMG - FRAMING
FLASH - FLASHING
FIN - FINISH
FLR - FLOOR
FDTN - FOUNDATION
A
AB - ANCHOR BOLT
ABBRV - ABBREVIATION
ACC - ACCESSIBLE
ADDM - ADDENDUM
AFF - ABOVE FINISH FLOOR
ADJ - ADJUSTABLE, ADJACENT
ALUM - ALUMINUM
& - AND
@ - AT
ARCH - ARCHITECT(URAL)
ALT - ALTERNATE
ASWG - AMERICAN STEEL WIRE GAUGE
ADA - AMERICAN WITH DISABILITIES ACT
∠ - ANGLE
ANOD - ANODIZE
APPROX - APPROXIMATE
B
BM - BEAM
BMS - BEAMS
BRG - BEARING
BRG PL - BEARING PLATE
BLDG - BUILDING
BLW - BELOW
BTWN - BETWEEN
BS - BOTH SIDES
BW - BOTH WAYS
BOT - BOTTOM
BDRY - BOUNDARY
BLDG - BUILDING
BAT - BATTEN, BATTERY
C
CEM - CEMENT
CTR - CENTER
CJ - CONSTRUCTION JOINT, CONTROL JOINT
COV - COVER
CIR - CIRCLE
CL. ℄ - CENTER LINE
C TO C - CENTER TO CENTER
CLR - CLEAR
COL - COLUMN
CONC - CONCRETE
CONT - CONTINUOUS
COTR - CONTRACTING OFFICER'S TECHNICAL
REPRESENTATIVE
CONST - CONSTRUCTION
COORD - COORDINATE
CTG - COATING
U
UON - UNLESS OTHERWISE NOTED
UNO - UNLESS NOTED OTHERWISE
V
VAR - VARIES
VEST - VESTIBULE
VERT - VERTICAL
VIF - VERIFY IN FIELD
W
WWF - WELDED WIRE FABRIC
W - WIDE
WB - WOOD BASE
WF - WIDE FLANGE
W/ - WITH
W/O - WITHOUT
WR - WATER RESISTANT
WP - WORK POINT
T
T - TREAD
THRESD - THRESHOLD
TC - TOP OF CURB
TEMP - TEMPORARY
TOB - TOP OF BEAM
TOC - TOP OF CONCRETE
TOF - TOP OF FLOOR
TOS - TOP OF SLAB, TOP OF STEEL
TYP - TYPICAL
XX
XXXX
XX
XXXX
1st FLOOR
EL. XX'-0"
FLOOR ELEVATION TARGET
OR TOP OF MATERIAL
DESIGNATION
BUILDING DATUM
ELEVATION
TITLE NAME
SCALE:
XX
XXXX
SECTION NUMBER
REFERENCE
SHEET NUMBER
DRAWING SYMBOLS
DETAIL NUMBER
REFERENCE
SHEET NUMBER
SECTION
INDICATOR
XX
XXXX
ELEVATION
NUMBER
REFERENCE
SHEET NUMBER
ELEVATION
INDICATOR
XX
XXXX
DETAIL NUMBER
REFERENCE
SHEET NUMBER
DETAIL SECTION
INDICATOR
X
XXX
DETAIL
INDICATOR
INTERIOR
ELEVATION
INDICATOR
DRAWING
ELEVATION IS
SHOWN
ELEVATION NUMBER
NORTH
ARROW
PLAN
NORTH
DRAWN:
CHECK:
SHT. NO.
SHEET TITLE
REV. NO.
DESIGN:
DATE:
COMM NO:
123456
E
D
A
B
C
123456
P e a c h tr e e D u n w o o d y R o a d
B u ild in g C
S u it e a n ta
.3
.1 y w ils o n .c o m
E m p lo y e e -O w n e d
/2
/2
:4
:5
P
M
C U s e rs
\s g e rh a rd t\ D o c u m e n ts
\2
L o x O b T o w e r_
R
C e n S tr u c s g e rh a rd tM J S
D W
.r v t
LEE ROAD - SHEET INDEX,
SYMBOLS, &
ABBREVIATIONS
U N
IT
E
D S
T A
T E
S F
IS
H
W
IL
D
L
IF
E S
E R
V
IC
E
RAB
SNG
02/25/2022
220146
G-002
SNG
L E
E R
O A
D S
IT
E
B
O Y
N T
O N
B E
A C
H
F L
O R
ID
A
A R
M L
O X
A H
A T
C H
E E
N A
T
IO
N A
L W
IL
D
L
IF
E R
E F
U G
E
L -4
O
B S
E R
V A
T
IO
N T
O W
E R
INDEX OF DRAWINGS
SHEET NUMBER SHEET NAME
G-001 LEE ROAD - COVER SHEET
G-002 LEE ROAD - SHEET INDEX, SYMBOLS, & ABBREVIATIONS
1 SPECIFIC PURPOSE SURVEY
C-001 LEE ROAD - ABBREVIATIONS, LEGEND, AND NOTES
C-002 LEE ROAD - VICINITY AND LOCATIONS MAPS
C-101 LEE ROAD - EXISTING CONDITIONS AND DEMOLITION PLAN
C-102 LEE ROAD - SITE PLAN
S-000 LEE ROAD - 3-DIMENSIONAL VIEW
S-001 LEE ROAD - STRUCTURAL GENERAL NOTES
S-002 LEE ROAD - SPECIAL INSPECTIONS
S-003 LEE ROAD - SPECIAL INSPECTIONS
S-100 FOUNDATION PLAN
S-101 LEE ROAD - TRANSFER LEVEL PLAN
S-102 LEE ROAD - RAMP PLAN
S-103 LEE ROAD - FIRST & SECOND FLOOR FRAMING PLANS
S-104 LEE ROAD - STAIR LANDING FRAMING
S-201 LEE ROAD - ELEVATIONS
S-202 LEE ROAD - ELEVATIONS
S-203 LEE ROAD - RAMP ELEVATIONS
S-204 LEE ROAD - RAMP ELEVATIONS
S-301 LEE ROAD - STRUCTURAL SECTIONS
S-302 LEE ROAD - STRUCTURAL SECTIONS
S-303 LEE ROAD - STAIR SECTIONS
S-304 LEE ROAD - STRUCTURAL FRAMING SECTIONS
S-305 LEE ROAD - STRUCTURAL FRAMING SECTIONS
S-306 LEE ROAD - TRANSFER SECTIONS
S-307 LEE ROAD - TRANSFER SECTIONS
S-308 LEE ROAD - TRANSFER SECTIONS
S-309 LEE ROAD - TRANSFER SECTIONS
S-310 STRUCTURAL SECTIONS & DETAILS
M R
K D
A T
E R
E V
I S
IO
N D
E S
C R
IP
T
L
N D S C A P E A
R C H
IT
E C T U R E
S U R V E Y
IN
G
C A U L F
IE
L D
W H E E L E R
IN
C
C
IV
IL
E
N G
IN
E E R
IN
P H O N E 1) -3
-1
F A X 1) -7
-1
G
L A D E S R
O A D
S U
IT
E
B O C A R
A T O N F L O R
ID
A
AutoCAD SHX Text
EOP
AutoCAD SHX Text
EOP
AutoCAD SHX Text
EOP
AutoCAD SHX Text
EOP
AutoCAD SHX Text
CONC SLAB
AutoCAD SHX Text
POSTED SIGN PARKING
AutoCAD SHX Text
TIMBER WALK
AutoCAD SHX Text
CONC WALK
AutoCAD SHX Text
CONC WALK
AutoCAD SHX Text
TIMBER WALK
AutoCAD SHX Text
CONC WALK
AutoCAD SHX Text
TIMBER WALK
AutoCAD SHX Text
TIMBER WALK
AutoCAD SHX Text
CONC SLAB
AutoCAD SHX Text
CONC SLAB
AutoCAD SHX Text
GUARD RAIL
AutoCAD SHX Text
SWING GATE
AutoCAD SHX Text
GUARD RAIL
AutoCAD SHX Text
POSTED SIGN TRAFFIC
AutoCAD SHX Text
OBSERVATION DECK
AutoCAD SHX Text
POSTED SIGN PARKING
AutoCAD SHX Text
BENCH MARK (3" CONC DISK) STAMPED "1-40-14" ELEVATION 22.72' (NAVD-88)
AutoCAD SHX Text
EDGE OF WATER (15.2' NAVD) 11/16/2020
AutoCAD SHX Text
TOP OF BANK
AutoCAD SHX Text
TOP OF BANK
AutoCAD SHX Text
GRASS
AutoCAD SHX Text
EDGE OF WATER (15.2' NAVD) 11/16/2020
AutoCAD SHX Text
OF SHEETS
AutoCAD SHX Text
JOB #
AutoCAD SHX Text
SHT.NO.
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text
F.B./ PG.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
FILE NAME
AutoCAD SHX Text
DATE
AutoCAD SHX Text
BY
AutoCAD SHX Text
AutoCAD SHX Text
AS SHOWN
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ELEC
AutoCAD SHX Text 11/30/20
AutoCAD SHX Text
SC
AutoCAD SHX Text
9135 BID ITEM 4 NAVD
AutoCAD SHX Text SPECIFIC PURPOSE SURVEY A PORTION OF SECTION 1, TOWNSHIP 46 SOUTH, RANGE 41 EAST PALM BEACH COUNTY, FLORIDA
AutoCAD SHX Text
SURVEY
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
LOCATION MAP (NTS) PALM BEACH COUNTY, FLORIDA
AutoCAD SHX Text
SITE
AutoCAD SHX Text
L-40 CANAL
AutoCAD SHX Text
AutoCAD SHX Text
INTENDED TO BE DISPLAYED AT
AutoCAD SHX Text
THE ABOVE SCALE OR SMALLER
AutoCAD SHX Text
HORIZONTAL SCALE: 1" = 10'
AutoCAD SHX Text 5'
AutoCAD SHX Text 10'
AutoCAD SHX Text 20'
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
LEE ROAD
AutoCAD SHX Text
SPECIFIC PURPOSE SURVEY, US FISH AND WILDLIFE SERVICE (BID ITEM #3)
AutoCAD SHX Text SURVEY NOTES: 1. REFER TO CAULFIELD AND WHEELER, INC. PROJECT NUMBER 9135 REFER TO CAULFIELD AND WHEELER, INC. PROJECT NUMBER 9135 2. THIS IS NOT A BOUNDARY SURVEY THIS IS NOT A BOUNDARY SURVEY 3. THIS SPECIFIC PURPOSE SURVEY WAS CONDUCTED NOVEMBER 16TH, 2020 AND PREFORMED TO PROVIDE CERTAIN LOCATIONS IN THE THIS SPECIFIC PURPOSE SURVEY WAS CONDUCTED NOVEMBER 16TH, 2020 AND PREFORMED TO PROVIDE CERTAIN LOCATIONS IN THE VICINITY OF THE LOXAHATCHEE NATIONAL WILDLIFE REFUGE, PALM BEACH COUNTY, FLORIDA AS DIRECTED BY THE CLIENT AND DEPICTED ON THE SURVEY MAP. 4. THE HORIZONTAL DATUM FOR THIS PROJECT REFERENCES THE FLORIDA EAST ZONE (901), TRANSVERSE MERCATOR PROJECTION OF THE THE HORIZONTAL DATUM FOR THIS PROJECT REFERENCES THE FLORIDA EAST ZONE (901), TRANSVERSE MERCATOR PROJECTION OF THE NORTH AMERICA DATUM OF 1983 (NAD 83/2007 ADJUSTMENT). COORDINATES PROVIDED ARE IN THE U.S. SURVEY FOOT UNIT OF MEASUREMENT. 5. THE VERTICAL DATUM REFERENCES THE NORTH AMERICA VERTICAL DATUM 1988 (NAVD-88) AND IS IN THE U.S. SURVEY FOOT UNIT OF THE VERTICAL DATUM REFERENCES THE NORTH AMERICA VERTICAL DATUM 1988 (NAVD-88) AND IS IN THE U.S. SURVEY FOOT UNIT OF MEASUREMENT. 6. PROJECT CONTROL: PROJECT CONTROL: 3" SURVEY DISK STAMPED STAMPED "1-40-14" STAMPED "1-40-14" N=787,578.62' E=910,685.62' ELEVATION=22.72' (NAVD-88) 7. THE VERTICAL AND HORIZONTAL DATA ARE RELATIVE TO FLORIDA DEPARTMENT OF TRANSPORTATION'S PERMANENT REFERENCE NETWORK THE VERTICAL AND HORIZONTAL DATA ARE RELATIVE TO FLORIDA DEPARTMENT OF TRANSPORTATION'S PERMANENT REFERENCE NETWORK 8. OTHER THAN THOSE SHOWN, NO BELOW GROUND IMPROVEMENTS OR FOUNDATIONS WERE LOCATED AS PART OF THIS SURVEY OTHER THAN THOSE SHOWN, NO BELOW GROUND IMPROVEMENTS OR FOUNDATIONS WERE LOCATED AS PART OF THIS SURVEY 9. THE INFORMATION DEPICTED HERON REPRESENTS THE RESULTS OF THE SURVEY ON THE DATE INDICATED AND CAN ONLY BE CONSIDERED AS INDICATING THE GENERAL CONDITIONS EXISTING AT THAT TIME. 9. LANDS SHOWN HEREON ARE NOT ABSTRACTED FOR RIGHTS OF WAY, EASEMENTS OWNERSHIPS, OR OTHER INSTRUMENTS OF RECORD, FURTHER THIS SURVEY DOES NOT IDENTIFY THE LIMITS OR EXTENT OF POTENTIAL JURISDICTIONAL BOUNDARIES. 10. THIS MAP IS NOT VALID WITHOUT THE SIGNATURE AND ORIGINAL SEAL OF FLORIDA LICENSED SURVEYOR AND MAPPER. 11. ADDITIONS OR DELETIONS TO THIS REPORT OR REFERENCED DIGITAL FILES BY OTHER THAN THE SIGNING PARTY IS PROHIBITED WITHOUT WRITTEN CONSENT OF THE UNDERSIGNED. CERTIFICATION I HEREBY CERTIFY TO THE BEST OF MY KNOWLEDGE AND BELIEF THAT THIS SPECIFIC PURPOSE SURVEY MEETS REQUIREMENTS SET FORTH IN RULE 5J-17 (STANDARDS OF PRACTICE) ADOPTED BY THE FLORIDA BOARD OF PROFESSIONAL SURVEYORS AND MAPPERS, PURSUANT TO FLORIDA STATUTE 472.027 AS SURVEYED UNDER MY DIRECTION. DAVID P. LINDLEY, VICE PRESIDENT PROFESSIONAL LAND SURVEYOR, REGISTRATION NO. 5005 LICENSED BUSINESS NUMBER 3591 NOVEMBER 30TH, 2020
220146
CAT
SMS
SMS
C-001
LEE ROAD - ABBREVIATIONS,
LEGEND AND NOTES
1. ALL WORK MUST BE PERFORMED IN STRICT COMPLIANCE WITH THE MOST CURRENT APPLICABLE FEDERAL, STATE , AND LOCAL LAWS AND REGULATIONS, INCLUDING BUT NOT LIMITED TO, ENVIRONMENTAL PROTECTION AGENCY (EPA), OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA), NATIONAL EMISSIONS STANDARDS FOR HAZARDOUS AIR POLLUTANTS (NESHAPS), AND NATIONAL INSTITUTE OF OCCUPATIONAL SAFETY AND HEALTH (NIOSH).
2. WHEN DURING THE COURSE OF CONSTRUCTION, ANY OBJECT OF AN UNUSUAL NATURE IS ENCOUNTERED, CEASE
WORK IN THAT AREA AND IMMEDIATELY NOTIFY THE CONTRACTING OFFICER.
3. DEMOLITION AND CONSTRUCTION OF THE PROJECT MUST NOT COMMENCE UNTIL THE APPROPRIATE EROSION AND
SEDIMENT CONTROL MEASURES ARE IN PLACE AS SPECIFIED ON THIS PLAN.
4. PROVIDE POSITIVE DRAINAGE AWAY FROM STRUCTURES IN ALL GRADED AREAS.
5. IF PORTABLE TOLIETS ARE NECESSARY FOR THE CONSTRUCTION OF THE PROJECT, LOCATE A MINIMUM OF 25 FEET
AWAY FROM THE NEAREST STORMWATER FEATURE (INLET, SWALE, POND, ETC.).
6. ALL SOLID WASTE, HAZARDOUS WASTE, AND HAZARDOUS MATERIALS MUST BE MANAGED IN ACCORDANCE WITH ALL
APPLICABLE FEDERAL, STATE, AND LOCAL ENVIRONMENTAL REGULATIONS.
7. ALL EXISTING UTILITIES MAY OR MAY NOT BE SHOWN IN THEIR EXACT LOCATION. CONTRACTOR TO VERIFY LOCATIONS
OF EXISTING UTILITIES PRIOR TO START OF DEMOLITION OR CONSTRUCTION.
8. REPAIR ANY ACTIVE UTILITIES DAMAGED DURING DEMOLITION OR CONSTRUCTION AND NOTIFY THE CONTRACTING
OFFICER OF THE DAMAGE.
9. LENGTHS OF LINES INDICATED ON THE DRAWINGS FOR UTILITY SYSTEMS ARE APPROXIMATE ONLY. DETERMINE THE EXACT AMOUNT OF PIPING REQUIRED TO FURNISH A COMPLETE WORKING SYSTEM IN ACCORDANCE WITH THE INTENT
OF THE DRAWINGS.
10. PHASE CONSTRUCTION IN ORDER TO MINIMIZE DISRUPTION TO UTILITIES DURING INSTALLATION, DEMOLITION, AND
REMOVAL.
11. CANAL CENTERLINE SHOWN BASED ON AHED CANALS AND STREAMS DATA SET DATED 01/22/2021 AND CANAL EDGE SHOWN BASED ON AHED WATERBODIES DATA SET DATED 01/22/2021 FROM THE SOUTH FLORIDA WATER MANAGEMENT DISTRICT GEOSPATIAL OPEN DATA WEBSITE AT HTTPS://GEO-SFWMD.HUB.ARCGIS.COM/. NO ACTUAL FIELD SURVEY
WAS PERFORMED TO LOCATE THESE FEATURES.
12. CANAL RIGHT OF WAY SHOWN BASED ON FIELD SURVEY INCLUDED ON SHEET V-001.
GENERAL CIVIL NOTES
THE PURPOSE OF THE EROSION CONTROL MEASURES SHOWN ON THESE PLANS IS TO
PRECLUDE THE TRANSPORT OF ALL WATERBORNE SEDIMENTS RESULTING FROM
CONSTRUCTION ACTIVITIES FROM ENTERING ONTO ADJACENT PROPERTIES OR STATE
WATERS. IF FIELD INSPECTION REVEALS THE INADEQUACY OF THE PLAN TO CONFINE
SEDIMENT TO THE PROJECT SITE, APPROPRIATE MODIFICATIONS WILL BE MADE TO
CORRECT ANY PLAN DEFICIENCIES.
1. THE CONTRACTOR MUST BE THOROUGHLY FAMILIAR WITH ALL APPROVED
PROCEDURES, WHICH MAY BE PERTINENT TO THE PROJECT. MAINTENANCE WILL
INCLUDE THE REPAIR OF MEASURES DAMAGED BY ANY SUBCONTRACTOR INCLUDING
THOSE OF THE PUBLIC UTILITY COMPANIES.
2. SEDIMENT CONTROL DEVICES NOT LOCATED IN PROPOSED FILL OR EXCAVATION
AREAS MUST BE CONSTRUCTED PRIOR TO ALL OTHER LAND DISTURBANCE.
3. SURFACE FLOWS OVER CUT AND FILL SLOPES MUST BE CONTROLLED BY REDIRECTING
FLOWS FROM TRAVERSING THE SLOPES.
4. SEDIMENT CONTROL MEASURES MAY REQUIRE MINOR FIELD ADJUSTMENTS AT THE
TIME OF CONSTRUCTION TO ENSURE THEIR INTENDED PURPOSE IS ACCOMPLISHED.
CONTRACTING OFFICER APPROVAL WILL BE REQUIRED FOR OTHER DEVIATION FROM
THE APPROVED PLANS.
5. TEMPORARY STOCKPILES OF SOIL / TOPSOIL EXCAVATED DURING SITE CONSTRUCTION
MUST BE KEPT ONSITE AT A TEMPORARY LOCATION IN ACCORDANCE WITH STATE AND
FEDERAL LAW.
6. TEMPORARY VEGETATIVE COVER MUST BE PROVIDED IN ALL AREAS WHICH ARE NOT
DESIGNATED FOR PAVING, UNDERGROUND UTILITIES, OR STRUCTURAL USES. SUCH
AREAS MUST NOT BE EXPOSED FOR PERIODS EXCEEDING 30 DAYS. TEMPORARY
VEGETATIVE COVER MAY BE ELIMINATED IN FAVOR OF FINAL VEGETATIVE COVER IF
CONSTRUCTION AND SEASONAL CONDITIONS PERMIT.
7. ALL AREAS DESIGNATED FOR PAVING, UNDERGROUND UTILITIES, AND STRUCTURAL
USE MUST BE COMPACTED, SEEDED, AND MULCHED AS SOON AS POSSIBLE BUT NOT
EXCEEDING 14 DAYS FOLLOWING INSTALLATION. NO MORE THAN 500' OF UTILITY
TRENCHES ARE TO BE OPEN AT ONE TIME.
8. THE TERM SEEDING, FINAL VEGETATIVE COVER OR STABILIZATION, ON THIS PLAN MUST
MEAN THE SUCCESSFUL GERMINATION AND ESTABLISHMENT OF A STABLE GRASS
COVER FROM A PROPERLY PREPARED SEEDBED CONTAINING THE SPECIFIED
AMOUNTS OF SEED, LIME, AND FERTILIZER. IRRIGATION MUST BE REQUIRED AS
NECESSARY TO ENSURE ESTABLISHMENT OF GRASS COVER.
9. INLET PROTECTION MUST BE PROVIDED FOR ALL CULVERTS AS SOON AS PRACTICAL.
10. BASE COURSE MATERIAL MUST BE PLACED IN ALL PAVED AREAS WITHIN 30 DAYS OF
FINAL GRADING.
11. TEMPORARY EROSION CONTROL MEASURES ARE NOT TO BE REMOVED UNTIL ALL
DISTURBED AREAS ARE STABILIZED. AFTER STABILIZATION IS COMPLETE, ALL
MEASURES MUST BE REMOVED WITHIN 30 DAYS. TRAPPED SEDIMENT MUST BE SPREAD
AND SEEDED.
12. SEED AND MULCH AND PROVIDE TOPSOIL TO ALL DISTURBED AREAS THAT WILL NOT BE
COVERED WITH PAVEMENT.
GENERAL EROSION AND SEDIMENT CONTROL NOTESABBREVIATIONS
DRAWN:
CHECK:
U N
IT
ED
S
TA
TE
S
FI
SH
W
IL
D
LI
FE
S
ER
VI
C
E
A.
R
.M . L
O
XA
H
AT
C H
EE
N
AT
IO
N
AL
W
IL
D
LI
FE
R
EF
U
G E
Pl ot
D at e:
/2 4/
0:
:3
AM
M R
K D
AT
E
R
EV
IS
IO
N D
ES
C
R
IP
TI
O
N
Fi le
P at h:
X
:\2
0\
F W
S Lo xa ha tc he e Sv cs \C
AD
\C iv il\
Sh ee ts \2
6A
_S 3C
1.
dw g
SHT. NO.
SHEET TITLE
REV. NO.
DESIGN:
DATE:
COMM NO:
123456
E
D
A
B
C
123456
P ea ch tre e D un w oo dy
R oa d, B ui ld in g
C
Su ite
At la nt a, G A
8.
0.
w ile yw ils on .c om
0%
E m pl oy ee -O w ne d
LE
E R
O
AD
S
IT
E, B
O
YN
TO
N
B
EA
C H
, F
LO
R
ID
A
- L
-4
O
BS
ER
VA
TI
O
N T
O W
ER
CBS CONCRETE BLOCK STRUCTURE
CLF CHAIN LINK FENCE
CLP CONCRETE LIGHT POLE
CMP CORRUGATED METAL PIPE
COE CORPS OF ENGINEERS
CONC CONCRETE
DE DRAINAGE EASEMENT
EOP EDGE OF PAVEMENT
EOW EDGE OF WATER
FH FIRE HYDRANT
INV INVERT
L LENGTH
LB LICENSED BUSINESS
LF LINEAR FEET
NAD-83 NORTH AMERICAN DATUM OF 1983
NAD-88 NORTH AMERICAN VERTICAL DATUM OF 1988
NGVD 29 NATIONAL GEODETIC VERTICAL DATUM OF 1929
NR NON RADIAL
NTS NOT TO SCALE
OHW OVERHEAD WIRES
ORB OFFICIAL RECORD BOOK
O/S BUILDING OFFSET
PBCR PALM BEACH COUNTY RECORDS
PG PAGE
PLS PROFESSIONAL LAND SURVEYOR
PP POWER POLE
R RADIUS
R/W RIGHT OF WAY
SFWMD SOUTH FLORIDA WATER
MANAGEMENT DISTRICT
SR STATE ROAD
TOB TOP OF BANK
TOE TOPE OF SLOPE
TYP TYPICAL
UE UTILITY EASEMENT
W WATER VALVE
Δ DELTA ANGLE
LEGEND AND SYMBOLS
TIMBER WALK
02/25/2022 x x x
TOP OF BANK
EDGE OF WATER
FENCE
TOE OF SLOPE
RIP-RAP
CONCRETE
BENCHMARK
EXISTING DESIGN
BOLLARD
SIGN
MAJOR CONTOURS
MINOR CONTOURS
CANAL CENTERLINE
sschad Image
© 2021 Microsoft Corporation © 2021 Maxar ©CNES (2021) Distribution Airbus DS
PROJECT SITE
220146
CAT
SMS
SMS
C-002
LEE ROAD - VICINITY AND
LOCATION MAPS
DRAWN:
CHECK:
U N
IT
ED
S
TA
TE
S
FI
SH
W
IL
D
LI
FE
S
ER
VI
C
E
A.
R
.M . L
O
XA
H
AT
C H
EE
N
AT
IO
N
AL
W
IL
D
LI
FE
R
EF
U
G E
Pl ot
D at e:
/2 4/
0:
:4
AM
M R
K D
AT
E
R
EV
IS
IO
N D
ES
C
R
IP
TI
O
N
Fi le
P at h:
X
:\2
0\
F W
S Lo xa ha tc he e Sv cs \C
AD
\C iv il\
Sh ee ts \2
6A
_S 3C
2.
dw g
SHT. NO.
SHEET TITLE
REV. NO.
DESIGN:
DATE:
COMM NO:
123456
E
D
A
B
C
123456
P ea ch tre e D un w oo dy
R oa d, B ui ld in g
C
Su ite
At la nt a, G A
8.
0.
w ile yw ils on .c om
0%
E m pl oy ee -O w ne d
LE
E R
O
AD
S
IT
E, B
O
YN
TO
N
B
EA
C H
, F
LO
R
ID
A
- L
-4
O
BS
ER
VA
TI
O
N T
O W
ER
VICINITY MAP
SCALE: 1" = 10,000'1 LOCATION MAP - PROJECT SITE
SCALE: 1" = 50'2
0 50' 100'
SCALE: 1" = 50'
IF THIS DRAWING IS REDUCED,
GRAPHIC SCALE MUST BE USED.
10000'0 20000'
SCALE: 1" = 10000'
02/25/2022
DRAWN:
CHECK:
U N
IT
ED
S
TA
TE
S
FI
SH
W
IL
D
LI
FE
S
ER
VI
C
E
A.
R
.M . L
O
XA
H
AT
C H
EE
N
AT
IO
N
AL
W
IL
D
LI
FE
R
EF
U
G E
Pl ot
D at e:
/2 4/
0:
:5
AM
M R
K D
AT
E
R
EV
IS
IO
N D
ES
C
R
IP
TI
O
N
Fi le
P at h:
X
:\2
0\
F W
S Lo xa ha tc he e Sv cs \C
AD
\C iv il\
Sh ee ts \2
6A
_S 3C
1.
dw g
SHT. NO.
SHEET TITLE
REV. NO.
DESIGN:
DATE:
COMM NO:
123456
E
D
A
B
C
123456
P ea ch tre e D un w oo dy
R oa d, B ui ld in g
C
Su ite
At la nt a, G A
8.
0.
w ile yw ils on .c om
0%
E m pl oy ee -O w ne d
LE
E R
O
AD
S
IT
E, B
O
YN
TO
N
B
EA
C H
, F
LO
R
ID
A
- L
-4
O
BS
ER
VA
TI
O
N T
O W
ER
02/25/2022
220146
CAT
SMS
SMS
C-101
LEE ROAD - EXISTING
CONDITIONS AND
DEMOLITION PLAN
GENERAL PLAN NOTES
1. SEE SHEET C-001 FOR SITE NOTES, LEGENDS, AND
ABBREVIATIONS
2. EXISTING TOWER FOUNDATION TO REMAIN. CONCRETE
FOUNDATION MUST BE PROTECTED DURING
DEMOLITION FOR REUSE. ANY DAMAGE TO THE
FOUNDATION WILL BE THE RESPONSIBILITY OF THE
CONTRACTOR TO REPAIR. SEE STRUCTURAL
DRAWINGS FOR FURTHER INFORMATION.
WORK NOTES
DETAIL
1 REMOVE TIMBER WALK N/A
2 REMOVE OBSERVATION DECK N/A
3 REMOVE EXISTING OBSERVATION SCOPE
AND RETAIN FOR INSTALLATION ON NEW
OBSERVATION TOWER
N/A
4 RETAIN AND PROTECT EXISTING
CONCRETE FOUNDATIONS N/A
5 REMOVE ALL VEGETATION WITHIN 5 FEET
OF FOUNDATIONS AND ENSURE WORK
DOES NOT UNDERMINE OR DAMAGE
EXISTING FOUNDATIONS. IF UNDERMINING
OR DAMAGE OCCURS, NOTIFY THE
CONTRACTING OFFICER AND FIX
IMMEDIATELY AT NO COST TO THE OWNER.
N/A
X
0 10' 20'
SCALE: 1" = 10'
IF THIS DRAWING IS REDUCED,
GRAPHIC SCALE MUST BE USED.
DRAWN:
CHECK:
U N
IT
ED
S
TA
TE
S
FI
SH
W
IL
D
LI
FE
S
ER
VI
C
E
A.
R
.M . L
O
XA
H
AT
C H
EE
N
AT
IO
N
AL
W
IL
D
LI
FE
R
EF
U
G E
Pl ot
D at e:
/2 4/
0:
:0
AM
M R
K D
AT
E
R
EV
IS
IO
N D
ES
C
R
IP
TI
O
N
Fi le
P at h:
X
:\2
0\
F W
S Lo xa ha tc he e Sv cs \C
AD
\C iv il\
Sh ee ts \2
6A
_S 3C
2.
dw g
SHT. NO.
SHEET TITLE
REV. NO.
DESIGN:
DATE:
COMM NO:
123456
E
D
A
B
C
123456
P ea ch tre e D un w oo dy
R oa d, B ui ld in g
C
Su ite
At la nt a, G A
8.
0.
w ile yw ils on .c om
0%
E m pl oy ee -O w ne d
LE
E R
O
AD
S
IT
E, B
O
YN
TO
N
B
EA
C H
, F
LO
R
ID
A
- L
-4
O
BS
ER
VA
TI
O
N T
O W
ER
02/25/2022
220146
CAT
SMS
SMS
C-102
LEE ROAD - SITE PLAN
GENERAL PLAN NOTES
1. SEE SHEET C-001 FOR SITE NOTES, LEGENDS, AND
ABBREVIATIONS
WORK NOTES
DETAIL
1 RAMP AND TOWER S3-S101
X
0 10' 20'
SCALE: 1" = 10'
IF THIS DRAWING IS REDUCED,
GRAPHIC SCALE MUST BE USED.
R
ID
A
L
IC
E N
S E
R
E O
B R
S A
S
IO
N A
N
GIN
E
L E
T S
B A
N o.
ER
PROF ES
S T
A T
E O
F
NOTE: CONTRACTOR IS RESPONSIBLE TO PROVIDE PROPER PROTECTION SUCH AS A TURBIDITY BARRIER, FENCING, AND WARNING SIGNAGE TO PROTECT ADJACENT PROPERTY/LEVEE FROM CONTAMINATION
OR HARM DUE TO CONSTRUCTION OPERATIONS.
DRAWN:
CHECK:
SHT. NO.
SHEET TITLE
REV. NO.
DESIGN:
DATE:
COMM NO:
123456
E
D
A
B
C
123456
P e a c h tr e e D u n w o o d y R o a d
B u ild in g C
S u it e a n ta
.3
.1 y w ils o n .c o m
E m p lo y e e -O w n e d
/2
/2
:4
:5
P
M
C U s e rs
\s g e rh a rd t\ D o c u m e n ts
\2
L o x O b T o w e r_
R
C e n S tr u c s g e rh a rd tM J S
D W
.r v t
LEE ROAD -
3-DIMENSIONAL VIEW
U N
IT
E
D S
T A
T E
S F
IS
H
W
IL
D
L
IF
E S
E R
V
IC
E
RAB
SNG
02/25/2022
220146
S-000
SNG
L E
E R
O A
D S
IT
E
B
O Y
N T
O N
B E
A C
H
F L
O R
ID
A
A R
M L
O X
A H
A T
C H
E E
N A
T
IO
N A
L W
IL
D
L
IF
E R
E F
U G
E
L -4
O
B S
E R
V A
T
IO
N T
O W
E R
M R
K D
A T
E R
E V
I S
IO
N D
E S
C R
IP
T
R
ID
A
L
IC
E N
S E
R
E O
B R
S A
S
IO
N A
N
GIN
E
L E
T S
B A
N o.
ER
PROF ES
S T
A T
E O
F
A. GENERAL
1. STRUCTURAL GENERAL NOTES ARE INTENDED TO HIGHLIGHT OR IN SOME CASES SUPPLEMENT
PROJECT SPECIFICATIONS. REFER TO THE PROJECT SPECIFICATIONS FOR COMPLETE WORK
COVERAGE.
2. THE DESIGN OF THE STRUCTURE COMPLIES WITH THE INTERNATIONAL BUILDING CODE 2018
AND FLORIDA BUILDING CODE 2020.
3. GRAVITY DESIGN LOADS ARE AS FOLLOWS:
A. DEAD LOADS
a. PLANK GRATING .....................................................................10 PSF
b. MISCELLANEOUS COMPONENTS.........................................5 PSF
B. LIVE LOADS
a. TYPICAL PLATFORM/RAMPS/STAIRS...................................100 PSF
b. HANDRAILS & GUARDRAILS
• TOP RAIL..................................50 PLF IN ANY DIRECTION AND 200 LB POINT LOAD IN ANY
DIRECTION NOT ACTING CONCURRENTLY
• INTERMEDIATE RAILS............50 LB HORIZONTAL NORMAL LOAD
• PANEL FILLERS.......................50 LB HORIZONTAL NORMAL LOAD ON ANY AREA NOT TO
EXCEED 12"X12"
4. IN ACCORDANCE WITH INTERNATIONAL BUILDING CODE’S SECTION 1607.4, THE FLOOR SYSTEM
IS DESIGNED TO WITHSTAND CONCENTRATED LOADS ASSUMED ACTING UNIFORMLY ON A 2-1/2
FEET SQUARE AREA AND LOCATED TO PRODUCE THE MAXIMUM EFFECT IN STRUCTURAL
MEMBERS.
5. LIVE LOADINGS HAVE BEEN REDUCED FOR ITEMS CARRYING MULTIPLE FLOORS (COLUMNS &
FOOTINGS), BUT NOT REDUCED FOR BEAMS AND PLANK GRATING DUE TO EXCEEDING 100 PSF
(REQUIREMENT IN ACCORDANCE WITH INTERNATIONAL BUILDING CODE 2018, SECTION
1607.9.1.)
6. THE DESIGN OF THE STRUCTURE TO RESIST SNOW LOADS IN ACCORDANCE WITH THE
INTERNATIONAL BUILDING CODE SECTION 1608 AND ASCE 7 CHAPTER 7. DESIGN INFORMATION
IS AS FOLLOWS
A. GROUND SNOW LOAD.................................................................Pg = 0 PSF B. FLAT ROOF/PLATFORM SNOW LOAD........................................Pf = 0 PSF
7. THE DESIGN OF THE STRUCTURE TO RESIST RAIN LOADS IN ACCORDANCE WITH
INTERNATIONAL BUILDING CODE’S SECTION 1611 AND ASCE 7 CHAPTER 8. THE RAIN INTENSITY, i, IS 4.04 IN/HR.
8. THE DESIGN OF THE STRUCTURE TO RESIST WIND PRESSURES IS IN ACCORDANCE WITH
INTERNATIONAL BUILDING CODE’S SECTION 1609.0, WHICH IS BASED ON ASCE 7, CHAPTER 26.
DESIGN INFORMATION IS AS FOLLOWS:
A. BASIC 3 SECOND GUST WIND SPEED (FIGURE 26.5-1B)........170 MILES PER HOUR
B. WIND EXPOSURE CATEGORY FOR MAIN WIND FORCE RESISTING SYSTEM.....C
C. INTERNAL PRESSURE COEFFICIENT....................................GCpi = +/-0.00 (OPEN STRUCTURE)
9. THE DESIGN OF THE STRUCTURE TO RESIST SEISMIC FORCES IS IN ACCORDANCE WITH
INTERNATIONAL BUILDING CODE’S SECTION 1613 AND ASCE 7.
A. OCCUPANCY CATEGORY............................................................II B. SEISMIC IMPORTANCE FACTOR (TABLE 1.5-2)........................Ie = 1.0
C. SPECTRAL RESPONSE ACCELERATIONS (USGS SEISMIC HAZARDS PROGRAM)
a. AT SHORT PERIODS................................................................Ss = 0.046g
b. AT ONE SECOND PERIOD......................................................S1 = 0.023g
D. SITE CLASS (TABLE 20.3-1)..........................................................D
E. SPECTRAL RESPONSE COEFFICIENTS
a. AT SHORT PERIODS................................................................Sds = 0.049 g
b. AT ONE SECOND PERIODS....................................................Sd1 = 0.037g
F. SEISMIC DESIGN CATEGORY (TABLES 11.6-1 & 11.6-2)...........A
G. BASIC SEISMIC FORCE RESISTING SYSTEM (TABLE 12.2-1)...STEEL SYSTEM NOT SPECIFICALLY
DETAILED FOR SEISMIC RESISTANCE
H. RESPONSE MODIFICATION FACTOR (TABLE 12.2-1)...............R = 3
I. SEISMIC RESPONSE COEFFICIENT............................................Cs = 0.016 J. DESIGN BASE SHEAR...................................................................V = 0.72 KIPS K. ANALYSIS PROCEDURE...............................................................EQUIVALENT LATERAL FORCE
10. IMPOSED CONSTRUCTION LOADS, INCLUDING CRANE LOADS, IN EXCESS OF STATED DESIGN
LOADS MUST BE APPROVED BY THE STRUCTURAL ENGINEER PRIOR TO THE IMPOSITION OF
SUCH LOADS OR CONTRACTOR SHALL PROVIDE PROPER DISTRIBUTION ELEMENTS IN ORDER
TO ENSURE THAT LIVE LOAD IS NOT EXCEEDED.
11. THE GENERAL CONTRACTOR AND SUB-CONTRACTORS SHALL DETERMINE THE SCOPE OF THE
STRUCTURAL WORK FROM THE CONTRACT DOCUMENTS TAKEN AS A WHOLE. THE
STRUCTURAL DRAWINGS SHALL NOT BE CONSIDERED SEPARATELY FOR PURPOSES OF
BIDDING THE WORK. DUE CONSIDERATION SHALL BE GIVEN TO OTHER STRUCTURAL WORK
OR WORK RELATED TO THE STRUCTURE, INCLUDING NECESSARY COORDINATION DESCRIBED
OR IMPLIED BY THE OTHER DISCIPLINES DRAWINGS.
12. THE REPRODUCTION OF THE STRUCTURAL CONTRACT DOCUMENTS IN ANY FASHION AS
STRUCTURAL SHOP DRAWING DOCUMENTS IS PROHIBITED.
13. SCALES NOTED ON THE DRAWINGS ARE FOR GENERAL INFORMATION ONLY. NO DIMENSIONAL
INFORMATION SHALL BE OBTAINED BY DIRECT SCALING OF THE DRAWINGS.
14. DETAILS, SECTIONS, AND NOTES SHOWN ON THESE DRAWINGS ARE INTENDED TO BE TYPICAL
AND SHALL APPLY TO SIMILAR CONDITIONS ELSEWHERE, EVEN IF NOT SPECIFICALLY
REFERENCED, UNLESS OTHERWISE SHOWN OR NOTED.
15. ANY SUBSTITUTIONS RESULTING IN REVISIONS TO THE STRUCTURE SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE WITH THE STRUCTURAL ENGINEER. AS
AN ALTERNATIVE ANY ALTERNATE DESIGNS MUST BE ACCOMPANIED BY A FULL ANALYSIS FOR
ALL AFFECTED COMPONENTS WHICH IS STAMPED BY AN ENGINEER LICENSED IN THE STATE OF
FLORIDA FOR CONTRACTING OFFICER REVIEW.
16. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF ALL RESULTING
REVISIONS TO THE STRUCTURAL SYSTEM AS A RESULT OF ACCEPTANCE OF CONTRACTOR
PROPOSED ALTERNATIVES OR SUBSTITUTIONS.
17. THE GENERAL CONTRACTOR (OR CONSTRUCTION MANAGER) SHALL SUBMIT SHOP DRAWINGS
FOR ALL STRUCTURAL ELEMENTS SHOWN ON THE CONTRACT DOCUMENTS FOR APPROVAL.
THE CONTRACTING OFFICER OR STRUCTURAL ENGINEER WILL NOT BE RESPONSIBLE FOR THE
STRUCTURAL CERTIFICATION AND DESIGN OF THE PROJECT IF THE GENERAL CONTRACTOR
FAILS TO OBTAIN APPROVAL OF THE SHOP DRAWINGS. SHOP DRAWINGS ARE REVIEWED AS A
CONVENIENCE TO THE GENERAL CONTRACTOR AND ARE NOT A CONTRACT DOCUMENT. THE
GENERAL CONTRACTOR SHALL STATE ON THE SHOP DRAWINGS THAT CONTRACT DOCUMENT
REQUIREMENTS HAVE BEEN MET AND THAT ALL DIMENSIONS, CONDITIONS AND QUANTITIES
HAVE BEEN REVIEWED AND VERIFIED AS SHOW N AND/OR CORRECTED ON THE SHOP
DRAWINGS.
18. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING TEMPORARY BRACING AND
SHORING, AS REQUIRED, TO ENSURE VERTICAL AND LATERAL STABILITY OF THE ENTIRE
STRUCTURE OR PORTION THEREOF DURING CONSTRUCTION FOR FULL DESIGN LOADINGS.
19. INFORMATION SHOWN REGARDING EXISTING CONDITIONS HAS BEEN OBTAINED BY LIMITED
OBSERVATIONS. AREAS NOT VISIBLE HAVE BEEN ASSUMED TYPICAL WITH OBSERVED EXISTING
CONDITIONS.
20. THE CONTRACTOR SHALL MEASURE AND PROVIDE ALL DIMENSIONS, ELEVATIONS AND
CONDITIONS AT THE JOB SITE PRIOR TO THE SUBMISSION OF SHOP DRAWINGS AND
CONSTRUCTION OR FABRICATION OF ANY ELEMENTS AND SHALL NOTIFY THE CONTRACTING
OFFICER IMMEDIATELY OF ANY DISCREPANCIES.
21. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR FITTING NEW WORK WITH EXISTING
CONSTRUCTION. INFORMATION ON EXISTING FOUNDATIONS SHOW N IN THESE DRAWINGS WAS
BASED UPON THE INFORMATION SUPPLIED TO WILEY WILSON, INC. THIS INFORMATION IS NOT
AS-BUILT DATA AND THE ACTUAL AS-BUILT CONSTRUCTION MAY DIFFER FROM THAT
REPRESENTED IN THE DRAWINGS. CONTRACTOR SHALL VERIFY ALL INFORMATION.
VARIATIONS FROM THE DIMENSIONS INDICATED ON THE CONTRACT DOCUMENTS SHALL BE
BROUGHT TO THE ATTENTION OF THE CONTRACTING OFFICER. CONTRACTOR IS RESPONSIBLE
FOR ANY COST OF REWORK ACCRUED DUE TO LACK OF VERIFICATION OF AS-BUILT
CONDITIONS.
22. METHODS, PROCEDURES, AND SEQUENCES OF CONSTRUCTION ARE THE RESPONSIBILITY OF
THE CONTRACTOR. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO
MAINTAIN AND INSURE THE INTEGRITY OF THE FOUNDATIONS AND THE LEVEE AT ALL STAGES
OF CONSTRUCTION.
23. CONTRACTOR MUST FABRICATE AND ERECT STEEL IN ACCORDANCE WITH OSHA’S SAFETY
REQUIREMENTS, 29 CFR 1926 SAFETY STANDARDS FOR STEEL ERECTION; FINAL RULE.
24. A REGISTERED ENGINEER SHALL DESIGN ALL NON-PRIMARY STRUCTURAL ELEMENTS SUCH AS
STAIRS, RAILINGS, AND PLANK GRATING TO MEET THE REQUIREMENTS OF THE LOCAL
GOVERNING JURISDICTION. SUBMIT CALCULATIONS AND SHOP DRAWINGS WITH THE
RESPONSIBLE ENGINEER’S SEAL AND SIGNATURE FOR THE STATE OF FLORIDA.
B. DEMOLITION
1. ALL WORK SHALL BE IN GENERAL COMPLIANCE WITH THE INTERNATIONAL BUILDING CODE 2018
AND 2020 FLORIDA BUILDING CODE.
2. FURNISH ALL LABOR AND MATERIALS NECESSARY TO PERFORM THE DEMOLITION WORK IN A
COMPLETED MANNER SUCH THAT NEW WORK CAN BE INSTALLED WITH MINIMUM PREPARATION.
3. SEE CIVIL DRAWING FOR EXISTING PLATFORM EXTENTS TO BE DEMOLISHED.
4. CONTRACTOR SHALL INCLUDE IN THE SCOPE OF WORK ALL ASPECTS OF REQUIRED DEMOLITION, SHORING OF EXISTING STRUCTURE, STAGING THE REPAIR TASKS AND SCHEDULING THE WORK
IN A MANNER APPROVED BY THE GOVERNMENT, CLEAN UP AFTER PORTIONS OF WORK ARE
PERFORMED AND CLEAN UP AFTER THE ENTIRE REPAIR IS COMPLETED.
5. CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL TEMPORARY SHORING AND BRACING
REQUIRED FOR DEMOLITION OPERATIONS. CONTRACTOR SHALL BE RESPONSIBLE FOR THE
DESIGN OF AND PROCEDURES FOR THE REQUIRED TEMPORARY SHORING. TEMPORARY
SHORING SHALL BE IN CONFORMANCE WITH OSHA REGULATIONS.
6. THE CONTRACTOR SHALL TAKE PRECAUTIONS TO PREVENT DAMAGE OF THE EXISTING
STRUCTURE (FOOTINGS) TO REMAIN AND SHALL TAKE CARE TO PREVENT ANY DAMAGE TO THE
LEVEE. IN THE EVENT OF DAMAGE, CONTRACTOR SHALL PROVIDE TEMPORARY SHORING AND
CONTACT THE CONTRACTING OFFICER FOR ASSESSMENT OF THE DAMAGE.
7. EXISTING BRACKETS MUST BE REMOVED, BUT EXISTING FOUNDATION ANCHOR BOLTS MAY
REMAIN IN PLACE IF THEY DO NOT INTERFERE WITH NEW CONSTRUCTION. THE AREA AROUND
THE BOLTS MUST BE CHIPPED DOWN AND PATCHED BACK IN ORDER TO PROTECT IT FROM THE
ENVIRONMENT.
8. SCHEDULE ALL WORK IN A CAREFUL MANNER WITH ALL NECESSARY CONSIDERATION FOR
ADJACENT FACILITY OPERATIONS, ACCESS OPERATIONS, AND GOVERNMENT PERSONNEL. ANY
DAMAGE TO PERSON OR PROPERTY AS A RESULT OF DEMOLITION AND RELATED WORK SHALL
BE THE RESPONSIBILITY OF THE CONTRACTOR.
9. ERECT BARRIERS FENCES, GUARDRAILS, WARNING DEVICES AND SHORING TO PROTECT
PERSONNEL WORKING IN THE AREA AND ADJACENT AREAS. IF ACCESS TO ANY ADJACENT AREAS
MUST BE SHUT DOWN FOR PUBLIC SAFETY THE CONTRACTOR MUST NOTIFY THE GOVERNMENT
IN WRITING A MINIMUM OF SEVEN (7) DAYS PRIOR TO SUSPENSION OF OPERATIONS.
10. SUBMIT PROCEDURES AND SCHEDULE PROPOSED FOR THE ACCOMPLISHMENT OF THE
DEMOLITION WORK TO THE CONTRACTING OFFICER FOR REVIEW. INCLUDE SAFE CONDUCT OF
THE WORK, DISPOSITION OF MATERIALS, PROTECTION OF REMAINING PROPERTY AND
COORDINATION WITH OTHER WORK.
11. THE CONTRACTOR SHALL TAKE MEASURES TO COORDINATE THE CONSTRUCTION SUCH THAT
INTERFERENCE OF EXISTING REINFORCING STEEL WITH PLACEMENT OF NEW ANCHORS
(DOWELS, EXPANSION BOLTS, ADHESIVE ANCHORS) DOES NOT OCCUR. IF EXISTING
REINFORCING STEEL IS ENCOUNTERED DURING DRILLING, ADJUST THE ANCHOR LOCATION IF
POSSIBLE AND NOTIFY THE CONTRACTING OFFICER. ABANDONED HOLES SHALL BE FILLED WITH
NON-METALLIC NON-SHRINK GROUT. ANCHORS SHALL BE SET WITHIN 3 INCHES OF THEIR
SPECIFIED LOCATION, BUT AT LEAST 1 INCH FROM ANY ABANDONED HOLE. CARE SHALL BE
TAKEN NOT TO BREAK OR DAMAGE REINFORCING STEEL DURING DRILLING, UNLESS OTHERWISE
DIRECTED BY THE CONTRACTING OFFICER.
C. CONCRETE
1. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH ACI 301, ACI 318, AND ACI 302.
2. ALL CONCRETE SHALL BE INSPECTED FOR CRACKS OR DEFICITS PRIOR TO START OF ERECTION OF NEW STEEL STRUCTURE. IF ANY CRACKS OR SPALLING IS VISIBLE CONTRACTOR SHALL NOTIFY
THE CONTRACTING OFFICER TO DETERMINE FURTHER ACTION PRIOR TO PROCEEDING.
3. SEE SPECIFICATIONS FOR ADDITIONAL INFO REGARDING CONCRETE MAINTENANCE. ASSUME 10
SQUARE FEET OF REPAIR FOR BIDDING PURPOSES.
4. PROVIDE CONCRETE WITH A MINIMUM COMPRESSIVE STRENGTH (f’c) OF 5000 PSI AT 28 DAYS AND
A MAXIMUM WATER/CEMENT RATIO OF 0.40. USE NORMAL WEIGHT AGGREGATES CONFORMING
TO ASTM C33 AND TYPE I/II PORTLAND CEMENT CONFORMING TO ASTM C150. CONCRETE SHALL
MEET THE FOLLOWING DURABILITY EXPOSURE CATEGORIES: F1, S0, W1, C2.
5. THE USE OF GROUND GRANULATED BLAST-FURNACE SLAG IS NOT PERMITTED.
6. FLY ASH CONFORMING TO ASTM C618, TYPE C OR F MAY BE USED AS TO REPLACE A PORTION OF
THE PORTLAND CEMENT IN A CONCRETE MIX. THE AMOUNT OF PORTLAND CEMENT CONTENT
SHALL NOT BE LESS THAN 70 PERCENT OF THE TOTAL AMOUNT OF CEMENTITIOUS MATERIAL IN
THE MIX.
7. CONCRETE REINFORCEMENT BARS SHALL CONFORM TO ASTM A615, GRADE 60. REINFORCEMENT
BARS SHALL NOT BE TACK WELDED, HEATED OR CUT UNLESS INDICATED ON THE CONTRACT
DOCUMENTS OR APPROVED BY THE STRUCTURAL ENGINEER.
8. GROUT UNDER ALL COLUMN BASE PLATES AND BEAM BEARING PLATES WITH NON-SHRINK, NON-
METALLIC GROUT SHALL CONFORM TO CORPS OF ENGINEERS SPECIFICATION CRD-C 621-82 OR
ASTM C1107.
9. DETAILING OF CONCRETE REINFORCEMENT BARS AND ACCESSORIES SHALL CONFORM TO THE
RECOMMENDATIONS OF ACI 315 “DETAILS AND DETAILING OF CONCRETE REINFORCEMENT” AND
ACI SP-66 “DETAILING MANUAL”. PLACING OF REINFORCING BARS SHALL CONFORM TO THE
RECOMMENDATIONS OF ACI 315R “MANUAL OF ENGINEERING AND PLACING DRAWINGS FOR
REINFORCED CONCRETE STRUCTURES” AND CRSI “MANUAL OF STANDARD PRACTICE”.
10. PROVIDE CONCRETE COVER PROTECTION OF REINFORCEMENT PER ACI 318 SECTION 20.6.1 WITH
STANDARD BAR CHAIRS AND SPACERS REQUIRED TO MAINTAIN MINIMUM CONCRETE
PROTECTION. COMMON MINIMUM CONCRETE COVERS WHICH APPLY TO THIS PROJECT:
A. CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH......3 INCHES
B. CONCRETE EXPOSED TO EARTH OR WEATHER
a. #6 BARS AND LARGER...............................................................2 INCHES
b. #5 BARS AND SMALLER.............................................................1-1/2 INCHES
11. REINFORCEMENT DESIGNATED AS “CONTINUOUS” SHALL LAP 48 BAR DIAMETERS AT SPLICES, UNLESS NOTED OTHERWISE.
12. TIE DOW ELS IN PLACE BEFORE PLACING CONCRETE. DO NOT STAB OR “WET-SET” DOWELS.
13. PRIOR TO PLACING NEW CONCRETE, ROUGHEN THE LOWER CONTACT SURFACE WITH ABOUT A ¼
INCH AMPLITUDE. REMOVE ANY LAITANCE FROM THE HARDENED CONTACT SURFACE AND
MAINTAIN A CLEAN CONTACT SURFACE FOR THE ADJOINING POUR.
14. CHAMFER EXPOSED EDGES OF CONCRETE ¾” UNLESS OTHERWISE NOTED.
15. PROTECT AND CURE ALL CONCRETE SURFACES. BEGIN CURING IMMEDIATELY AFTER STRIPPING
FORMS AND FLATWORK IMMEDIATELY AFTER FINISHING. CONCRETE CURING OF FORMED
SURFACES SHALL BE ACHIEVED BY MOISTURE RETAINING MATERIALS OR PLASTIC FILM IF THE
FORMS ARE REMOVED BEFORE THE END OF THE CURING PERIOD.
16. CONCRETE FINISHING OF CONCRETE SLAB SHALL CONSIST OF FINE BROOM FINISH.
D. POST-INSTALLED ANCHORS
1. POST-INSTALLED ANCHORS SHALL ONLY BE USED WHERE SPECIFIED ON THE CONSTRUCTION
DOCUMENTS.
2. ANCHORAGE TO CONCRETE:
A. MECHANICAL ANCHORS SHALL HAVE BEEN TESTED AND QUALIFIED FOR USE IN
ACCORDANCE W ITH ACI 355.2 AND ICC-ES AC193 FOR CRACKED AND UNCRACKED CONCRETE
RECOGNITION.
B. ADHESIVE ANCHORS SHALL HAVE BEEN TESTED AND QUALIFIED FOR USE IN ACCORDANCE
WITH ACE 355.4 AND ICC-ES AC 308 FOR CRACKED AND UNCRACKED CONCRETE
RECOGNITION.
3. INSTALL ANCHORS PER THE MANUFACTURER INSTRUCTIONS, AS INCLUDED IN THE ANCHOR
PACKAGING.
4. ANCHOR CAPACITY IS DEPENDANT UPON SPACING BETWEEN ADJACENT ANCHORS AND
PROXIMITY OF ANCHORS TO EDGE OF CONCRETE. INSTALL ANCHORS IN ACCORDANCE WITH
SPACING AND EDGE CLEARANCES INDICATED ON THE DRAWINGS. IF ANCHORS CANNOT BE
INSTALLED PER DIMENSIONS SHOWN THE CONTRACTOR SHALL NOTIFY THE CONTRACTING
OFFICER PRIOR TO PROCEEDING.
5. THE CONTRACTOR SHALL TAKE MEASURES TO COORDINATE THE CONSTRUCTION SUCH THAT
INTERFERENCE OF EXISTING REINFORCING STEEL W ITH PLACEMENT OF NEW ANCHORS
(DOWELS, EXPANSION BOLTS, ADHESIVE ANCHORS) DOES NOT OCCUR. IF EXISTING
REINFORCING STEEL IS ENCOUNTERED DURING DRILLING, ADJUST THE ANCHOR LOCATION IF
POSSIBLE AND NOTIFY THE CONTRACTING OFFICER. ABANDONED HOLES SHALL BE FILLED
WITH GROUT. ANCHORS SHALL BE SET WITHIN 3 INCHES OF THEIR SPECIFIED LOCATION, BUT
AT LEAST 1 INCH FROM ANY ABANDONED HOLE. CARE SHALL BE TAKEN NOT TO BREAK OR
DAMAGE REINFORCING STEEL DURING DRILLING, UNLESS OTHERWISE DIRECTED.
E. STRUCTURAL STEEL
1. UNLESS NOTED OTHERWISE, STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING:
A. ANCHOR BOLTS............................................ASTM F1554, GRADE 55
B. ANGLES..........................................................ASTM A36
C. PLATES...........................................................ASTM A572 (Fy = 50 KSI) D. HSS RECTANGULAR.....................................ASTM A500, GRADE B (Fy = 46 KSI) E. HSS ROUND...................................................ASTM A500, GRADE B (Fy = 42 KSI) F. STEEL PIPE....................................................ASTM A53, GRADE B (Fy = 35 KSI)
G. ROUND BAR...................................................ASTM A36
H. SUBMIT MILL TEST REPORTS FOR REVIEW.
2. BOLTS FOR STRUCTURAL STEEL CONNECTIONS SHALL BE HIGH STRENGTH BOLTS PER THE
REQUIREMENTS OF ASTM A325, TYPE N, X, or SC. UNLESS NOTED OTHERWISE, PROVIDE BOLTS DESIGNED AS BEARING TYPE BOLTS AND INSTALL PER THE “SNUG TIGHT” CONDITION. IF SLOTTED
CONNECTIONS ARE USED FOR EASE OF ERECTION, CONNECTIONS MUST BE A MINIMUM OF PRE-
TENSIONED CONNECTIONS THROUGH USE OF TENSION INDICATOR WASHERS OR TWIST OFF
TENSION INDICATOR BOLTS. INSTALL A HARDENED W ASHER UNDER THE ELEMENT TO BE
TIGHTENED. FOR "SLIP CRITICAL" TYPE CONNECTIONS, USE COMPRESSIBLE WASHERS
COMPLYING WITH ASTM F959 TYPE 325-3 DIRECT TENSION INDICATORS.
3. DETAIL, FABRICATE, AND ERECT STRUCTURAL STEEL PER THE AISC “SPECIFICATION FOR
STRUCTURAL STEEL BUILDINGS,” THE AISC “CODE OF STANDARD PRACTICE FOR STEEL
BUILDINGS AND BRIDGES” AND THE SAFETY REQUIREMENTS OF THE OCCUPATIONAL SAFETY
AND HEALTH ADMINISTRATION AND THE LOCAL JURISDICTION. PROVIDE TEMPORARY SEATS TO
FACILITATE SAFE ERECTION.
4. THE FABRICATOR SHALL PREPARE THE SHOP DRAWINGS BASED ON DESIGN LOADS PROVIDED
OR CONNECTION DESIGN INFORMATION SHOWN IN THE TYPICAL DETAILS. THE FABRICATOR IS
RESPONSIBLE FOR CHOOSING, DESIGNING AND DETAILING ALL CONNECTIONS PARTIALLY
DETAILED IN THE CONTRACT DRAWINGS IN ACCORDANCE WITH PART 10 OF THE AISC “MANUAL
OF STEEL CONSTRUCTION” THIRTEENTH EDITION.
5. FABRICATOR'S EXPERIENCED STEEL DETAILER SHALL SELECT OR COMPLETE CONNECTIONS IN
ACCORDANCE WITH ANSI/AISC 303. CONNECTIONS SHALL BE COMPLETED USING SCHEMATIC
DETAILS INDICATED AND ANSI/AISC 360. LOADS INDICATED IN THE DRAWINGS ARE ALLOWABLE
STRESS DESIGN AND ARE GIVEN AT SERVICE LOAD LEVEL.
6. IF THE FABRICATOR USES ALTERNATE CONNECTION DESIGNS, A PROFESSIONAL ENGINEER
REGISTERED IN THE STATE OF FLORIDA SHALL SEAL AND SIGN THE CONNECTION DESIGNS AND
SUBMIT WITH THE SHOP DRAWINGS.
7. PERFORM WELDING IN ACCORDANCE WITH THE AMERICAN WELDING SOCIETY STANDARD D1.1.
PROVIDE ELECTRODES FOR SHOP AND FIELD WELDS IN ACCORDANCE WITH AW S A5.1 OR AWS
A5.5, CLASS E70XX, LOW HYDROGEN. ALL WELDS SHALL USE FILLER METAL WITH A MINIMUM CVN
VALUE OF 20 FT-LBS AT -20 DEGREES FAHRENHEIT.
8. ALL SHOP AND FIELD WELDING SHALL BE EXECUTED BY WELDERS AND WELDING OPERATORS
WHO HAVE BEEN PREVIOUSLY QUALIFIED BY TEST AS PRESCRIBED IN AWS D1.1 OF THE
AMERICAN WELDING SOCIETY TO PERFORM THE TYPES OF WELDS REQUIRED ON THE PROJECT.
9. SHOP OR FIELD W ELDS AT NON-BOLTED CONNECTIONS THAT ARE NOT SPECIFICALLY DETAILED
SHALL BE 3/16” CONTINUOUS FILLETS AT EACH CONTACT EDGE OR SURFACE. FIELD WELDING
SHALL BE AVOIDED AND CONTRACTOR SHALL NOTIFY CONTRACTING OFFICER PRIOR TO FIELD
WELDING IF IT CAN NOT BE AVOIDED.
10. RETURN ALL WELDS AT CORNERS TWICE THE NOMINAL SIZE OF THE WELD MINIMUM, UNLESS
OTHERW ISE NOTED.
11. ALL COPES, BLOCKS, CUT OUTS, AND OTHER CUTTING OF STRUCTURAL MEMBERS SHALL HAVE
ALL RE-ENTRANT CORNERS SHAPED, NOTCHED FREE TO A RADIUS OF AT LEAST ½”.
12. SEE OTHER DRAWINGS FOR MISCELLANEOUS STEEL NOT SHOWN ON THE STRUCTURAL
DRAWINGS.
13. NO FABRICATION SHALL PROCEED PRIOR TO SHOP DRAWING APPROVAL.
14. NO OPENINGS IN BEAMS OR COLUMNS ARE PERMITTED WITHOUT CONTRACTING OFFICER’S
WRITTEN APPROVAL.
15. SPLICING OF STRUCTURAL STEEL MEMBERS WHERE NOT DETAILED ON THE CONTRACT
DOCUMENTS IS PROHIBITED WITHOUT PRIOR APPROVAL OF THE STRUCTURAL ENGINEER AS TO
LOCATION, TYPE OF SPLICE AND CONNECTION TO BE MADE.
16. THE CONTRACTOR SHALL NOTIFY CONTRACTING OFFICER OF ANY MISFABRICATION
STRUCTURAL STEEL PRIOR TO ERECTION OF SAME.
17. WHERE NO UPWARD CAMBER IS SHOWN ON THE CONTRACT DOCUMENTS, ANY MILL CAMBER
SHALL BE DETAILED UPWARD IN THE BEAMS.
18. ALL STEEL SHALL BE HOT DIPPED GALVANIZED. STEEL SHAPES, PLATES AND BARS SHALL BE
GALVANIZED PER ASTM A123. STEEL BOLTS, NUTS AND WASHERS SHALL BE GALVANIZED PER
ASTM A153, CLASS C. DAMAGED AND UNCOATED AREAS SHALL BE REPAIRED PER ASTM A780.
19. ALL TUBE STEEL SHALL HAVE A MINIMUM OF 3/8" CAP PLATES, TYPICAL. CONTRACTOR/STEEL
FABRICATOR/GALVANIZER IS RESPONSIBLE FOR PROPER VENTING OF TUBE STEEL DURING
GALVANIZATION PROCESS. CONTRACTOR/STEEL ERECTOR ARE RESPONSIBLE FOR CAPPING
VENT HOLES THROUGH USE OF FREEZE PLUGS OR OTHER MEANS AFTER GALVANIZING HAS
TAKEN PLACE AND PRIOR TO SUBSTANTIAL COMPLETION.
20. WORK POINTS SHALL BE AT INTERSECTIONS OF BEAM, COLUMN, AND BRACE CENTERLINES, UNO. SEE DETAILS FOR SPECIFIC DIMENSIONS. FOR MEMBERS WHICH ARE NOT DOUBLY
SYMMETRIC THE CENTROID OF THE MEMBER SHALL BE USED.
F. STRUCTURAL ALUMINUM
1. UNLESS NOTED OTHERWISE, STRUCTURAL ALUMINUM SHALL MEET THE REQUIREMENTS OF
ALUMINUM ALLOY TYPE 6061-T6. SUBMIT MILL TEST REPORTS FOR REVIEW.
2. BOLTS FOR STRUCTURAL ALUMINUM CONNECTIONS SHALL BE ALUMINUM ALLOY TYPE 2024-T4, UNLESS NOTED OTHERWISE. PROVIDE BOLTS DESIGNED AS BEARING TYPE BOLTS AND INSTALL
PER THE “SNUG-TIGHT” CONDITION. NUTS SHALL BE ALUMINUM ALLOY TYPE 6061-T6 AND FLAT
WASHERS SHALL BE ALUMINUM ALLOY ALCLAD 2024-T4. INSTALL A WASHER UNDER THE
ELEMENT TO BE TIGHTENED.
3. AS AN ALTERNATE, BOLTS USED TO CONNECT STEEL AND ALUMINUM COMPONENTS MAY BE
STRONGWELL FIBREBOLT WITH FIBERGLASS STUDS AND NUTS OR APPROVED EQUIVALENT.
4. DETAIL, FABRICATE, AND ERECT STRUCTURAL ALUMINUM PER THE ALUMINUM DESIGN MANUAL
AND THE SAFETY REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION
AND THE LOCAL JURISDICTION.
5. ALL WELDING SHALL CONFORM WITH AWS D1.2, LATEST STRUCTURAL WELDING CODE-
ALUMINUM.
6. WHERE THE CONTACT OF DISSIMILAR METALS MAY CAUSE CORROSION OR WHERE ALUMINUM
WILL COME IN CONTACT W ITH CONCRETE, MORTAR, OR PLASTER, THE CONTACT SURFACE OF
THE ALUMINUM SHALL BE COATED WITH 1 COAT OF ZINC CHROMATE PRIMER AND ONE HEAVY
COAT OF ALUMINUM PIGMENTED ASPHALT PAINT.
7. NEOPRENE BEARING PADS BETWEEN MATERIALS SHALL HAVE A MINIMUM SHORE A DUROMETER
HARDNESS OF 60 AND A YOUNG'S MODULUS OF 635 PSI.
DRAWN:
CHECK:
SHT. NO.
SHEET TITLE
REV. NO.
DESIGN:
DATE:
COMM NO:
123456
E
D
A
B
C
123456
P e a c h tr e e D u n w o o d y R o a d
B u ild in g C
S u it e a n ta
.3
.1 y w ils o n .c o m
E m p lo y e e -O w n e d
/2
/2
:4
:5
P
M
C U s e rs
\s g e rh a rd t\ D o c u m e n ts
\2
L o x O b T o w e r_
R
C e n S tr u c s g e rh a rd tM J S
D W
.r v t
LEE ROAD - STRUCTURAL
GENERAL NOTES
U N
IT
E
D S
T A
T E
S F
IS
H
W
IL
D
L
IF
E S
E R
V
IC
E
RAB
SNG
02/25/2022
220146
S-001
SNG
L E
E R
O A
D S
IT
E
B
O Y
N T
O N
B E
A C
H
F L
O R
ID
A
A R
M L
O X
A H
A T
C H
E E
N A
T
IO
N A
L W
IL
D
L
IF
E R
E F
U G
E
L -4
O
B S
E R
V A
T
IO
N T
O W
E R
M R
K D
A T
E R
E V
I S
IO
N D
E S
C R
IP
T
R
ID
A
L
IC
E N
S E
R
E O
B R
S A
S
IO
N A
N
GIN
E
L E
T S
B A
N o.
ER
PROF ES
S T
A T
E O
F
DRAWN:
CHECK:
SHT. NO.
SHEET TITLE
REV. NO.
DESIGN:
DATE:
COMM NO:
123456
E
D
A
B
C
123456
P e a c h tr e e D u n w o o d y R o a d
B u ild in g C
S u it e a n ta
.3
.1 y w ils o n .c o m
E m p lo y e e -O w n e d
/2
/2
:4
:5
P
M
C U s e rs
\s g e rh a rd t\ D o c u m e n ts
\2
L o x O b T o w e r_
R
C e n S tr u c s g e rh a rd tM J S
D W
.r v t
LEE ROAD - SPECIAL
INSPECTIONS
U N
IT
E
D S
T A
T E
S F
IS
H
W
IL
D
L
IF
E S
E R
V
IC
E
RAB
SNG
02/25/2022
220146
S-002
SNG
L E
E R
O A
D S
IT
E
B
O Y
N T
O N
B E
A C
H
F L
O R
ID
A
A R
M L
O X
A H
A T
C H
E E
N A
T
IO
N A
L W
IL
D
L
IF
E R
E F
U G
E
L -4
O
B S
E R
V A
T
IO
N T
O W
E R
11. DOCUMENT ACCEPTANCE OR
REJECTION OF ALL BOLTED
CONNECTIONS
DOCUMENT
TASK
INSPECTION
TYPE
DESCRIPTION
STEEL INSPECTION AFTER BOLTING-VERIFY THE FOLLOWING ARE IN COMPLIANCE WITH IBC 2015 1705.2.1, AISC 360-10: TABLE C-N5.6-3
10. BOLTS ARE PRETENSIONED IN
ACCORDANCE WITH RCSC
SPECIFICATION, PROGRESSING
SYSTEMATICALLY FROM THE MOST
RIGID POINT TOWARD THE FREE
EDGES
OBSERVE
9. FASTENER COMPONENT NOT TURNED
BY THE WRENCH PREVENTED FROM
ROTATING
OBSERVE
8. JOINT BROUGHT TO THE SNUG-TIGHT
CONDITION PRIOR TO PRETENSIONING
OPERATION
OBSERVE
7. FASTENER ASSEMBLIES OF SUITABLE
CONDITION PLACED IN ALL HOLES AND
WASHERS (IF REQUIRED) ARE
POSITIONED AS REQUIRED
OBSERVE
TASK
INSPECTION
TYPE
DESCRIPTION
STEEL INSPECTION DURING BOLTING-VERIFY THE FOLLOWING ARE IN COMPLIANCE WITH IBC 1705.2.1, AISC 360-10: TABLE C-N5.6-2
6. PROPER STORAGE PROVIDED FOR
BOLTS, NUTS, WASHERS, AND OTHER
FASTENER COMPONENTS
OBSERVE
5. CONNECTING ELEMENTS, INCLUDING
APPROPRIATE FAYING SURFACE
CONDITION AND HOLE PREPARATION,
IF SPECIFIED, MEET APPLICABLE
REQUIREMENTS
OBSERVE
4. PROPER BOLTING PROCEDURE
SELECTED FOR JOINT DETAIL OBSERVE
3. PROPER FASTENERS SELECTED FOR
JOINT DETAIL GRADE, TYPE, BOLT
LENGTH IF THREADS ARE TO BE
EXCLUDED FROM SHEAR PLANE)
OBSERVE
2. FASTENERS MARKED IN ACCORDANCE
WITH ASTM REQUIREMENTS OBSERVE
1. MANUFACTURER'S CERTIFICATIONS
AVAILABLE FOR FASTENER MATERIALS PERFORM
TASK
INSPECTION
TYPE
DESCRIPTION
STEEL INSPECTION PRIOR TO BOLTING-VERIFY THE FOLLOWING ARE IN COMPLIANCE WITH IBC 1705.2.1, AISC 360-10: TABLE C-N5.6-1
STRUCTURAL STEEL- BOLTING SECTION
Y
10. INSPECT FORMWORK FOR SHAPE,
LOCATION, AND DIMENSIONS OF THE
CONCRETE MEMBER BEING FORMED
OBSERVE
Y
9. VERIFY MAINTENANCE OF SPECIFIED
CURING TEMPERATURE AND TECHNIQUE
OBSERVE
INSPECT CURING, COLD WEATHER PROTECTION, AND HOT
WEATHER PROTECTION PROCEDURES
Y
8. INSPECT CONCRETE PLACEMENT FOR
PROPER APPLICATION TECHNIQUES
CONTINUOUS
VERIFY PROPER APPLICATION TECHNIQUES ARE USED
DURING CONCRETE CONVEYANCE AND DEPOSITING AVOIDS
SEGREGATION OR CONTAMINATION. VERIFY THAT CONCRETE
IS PROPERLY CONSOLIDATED
Y
7. PRIOR TO CONCRETE PLACEMENT,
FABRICATE SPECIMENS FOR STRENGTH
TESTS, PERFORM SLUMP AND AIR
CONTENT TESTS, AND DETERMINE THE
TEMPERATURE OF THE CONCRETE
CONTINUOUS
AT THE TIME FRESH CONCRETE IS SAMPLED TO FABRICATE
SPECIMENS FOR STRENGTH TEST VERIFY THESE TESTS ARE
PERFORMED BY QUALIFIED TECHNICIANS
Y 6. VERIFY USE OF REQUIRED MIX DESIGN OBSERVE
VERIFY THAT ALL MIXES USED COMPLY WITH THE APPROVED
CONSTRUCTION DOCUMENTS
Y
5. POST-INSTALLED ADHESIVE ANCHORS IN
HORIZONTAL OR UPWARD INCLINED
ORIENTATION
CONTINUOUS
& DOCUMENT
-INSPECT AS REQUIRED PER APPROVED ICC-ES REPORT
-VERIFY THAT INSTALLER IS CERTIFIED FOR INSTALLATION OF
HORIZONTAL AND OVERHEAD APPLICATIONS
-INSPECT PROOF LOADING AS REQUIRED BY THE CONTRACT
DOCUMENTS
Y 4.
CAST IN PLACE ANCHORS AND POST
INSTALLED DRILLED ANCHORS
(DOWNWARD INCLINED)
OBSERVE
VERIFY PRIOR TO PLACING CONCRETE THAT CAST IN PLACE
ANCHOR AND POST INSTALLED DRILLED ANCHORS HAVE
PROPER EMBEDMENT, SPACING, AND EDGE DISTANCE
N
3. ALL OTHER WELDING
CONTINUOUS
VISUALLY INSPECT ALL WELDS IN ACCORDANCE WITH AWS
D1.4
N
2. REINFORCING BAR WELDING
OBSERVE
-VERIFY WELDABILITY OF REINFORCING BARS OTHER THAN
ASTM A 706
-INSPECT SINGLE-PASS FILLET WELDS, MAXIMUM 5/16" IN
ACCORDANCE WITH AWS D1.4
Y
1. INSPECT REINFORCEMENT AND VERIFY
PLACEMENT
OBSERVE
VERIFY PRIOR TO PLACING CONCRETE THAT REINFORCING IS
OF SPECIFIED TYPE, GRADE AND SIZE; THAT IT IS FREE OF
OIL, DIRT AND UNACCEPTABLE RUST; THAT IS LOCATED AND
SPACED PROPERLY; THAT HOOKS, BENDS, TIES, STIRRUPS
AND SUPPLEMENTAL REINFORCEMENT ARE PLACED
CORRECTLY; THAT LAP LENGTHS, STAGGER AND OFFSETS
ARE PROVIDED; AND THAT ALL MECHANICAL CONNECTIONS
ARE INSTALLED PER THE MANUFACTURER'S INSTRUCTIONS
AND/OR EVALUATION REPORT
INSPECTION
REQ (Y/N)
TASK
INSPECTION
TYPE
DESCRIPTION
CONCRETE CONSTRUCTION, INCLUDING COMPOSITE DECK - VERIFY THE FOLLOWING ARE IN COMPLIANCE
IBC 1705.3, 1(ACI 318 REFERENCES NOTED IN IBC TABLE)
STRUCTURAL - CONCRETE CONSTRUCTION SECTION
M R
K D
A T
E R
E V
I S
IO
N D
E S
C R
IP
T
IO
N
NOTE:
CONTRACTOR IS RESPONSIBLE TO HIRE A THIRD PARTY/INDEPENDENT SPECIAL INSPECTOR AT CONTRACTOR'S EXPENSE. SPECIAL INSPECTOR MUST BE NOTIFIED ONE WEEK PRIOR TO BEGINNING ANY WORK REQUIRING INSPECTION. ANY WORK COMPLETED WITHOUT PROPER INSPECTION IS SUBJECT TO REMOVAL. IT WILL BE AT THE COR'S DISCRETION ON WHETHER ADDITIONAL TESTING MUST BE CONDUCTED AT THE CONTRACTOR'S EXPENSE OR IF WORK MUST BE REMOVED AND RECONSTRUCTED.
REPORTS MUST BE COMPLETED AND ISSUED TO THE COR FOR REVIEW WITHIN A WEEK OF THE INSPECTION.
ACCEPTABLE INSPECTOR AVAILABLE, BUT NOT LIMITED TO:
NOVA ENGINEERING & ENVIRONMENTAL, 201 SOUTH BISCAYNE BOULEVARD, 28TH FLOOR, MIAMI, FLORIDA 33131 - OFFICE 954-424-2520
SPECIAL INSPECTOR QUALIFICATIONS MUST BE SUBMITTED TO COR FOR REVIEW PRIOR TO INSPECTIONS BEING CONDUCTED. SPECIAL INSPECTOR MUST HAVE A MINIMUM
OF FIVE (5) YEARS SPECIAL INSPECTION EXPERIENCE.
R
ID
A
L
IC
E N
S E
R
E O
B R
S A
S
IO
N A
N
GIN
E
L E
T S
B A
N o.
ER
PROF ES
S T
A T
E O
F
DRAWN:
CHECK:
SHT. NO.
SHEET TITLE
REV. NO.
DESIGN:
DATE:
COMM NO:
123456
E
D
A
B
C
123456
P e a c h tr e e D u n w o o d y R o a d
B u ild in g C
S u it e a n ta
.3
.1 y w ils o n .c o m
E m p lo y e e -O w n e d
/2
/2
:4
:5
P
M
C U s e rs
\s g e rh a rd t\ D o c u m e n ts
\2
L o x O b T o w e r_
R
C e n S tr u c s…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .