This document is a Statement of Work (SOW) for a Purchase Order to replace the existing Synergy Lighting Control System in Building 91029 at Hurlburt Field, Florida. The contractor shall remove the existing control panels, one-button switches, and power supply, and install a new Unison EchoTouch Dimmer Control System, including all associated equipment and electrical connections. The work shall be performed during normal duty hours, and the contractor shall coordinate with the Contracting Officer and Facility Manager prior to and during execution. The requirement is set aside for small businesses under NAICS code 238210, with a size standard of $19M. The procurement method is lowest priced technically acceptable evaluation of commercial items.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Title: Replace Dimmer Control System 492 SOTRSS B91029, Hurlburt Field, FL

Date: 23 July 2024

Statement of Work

1. GENERAL

1.0 The following Statement of Work is for a Purchase Order to be accomplished by the contractor in accordance with commercial building and electrical codes.

1.1 The contractor shall provide all plant, labor, materials, equipment, design, and supervision necessary to “Remove and Replace an existing Dimmer Control System”. All work shall be done in accordance with commercial building and electrical codes.

1.2 Contractor shall coordinate with the Bldg 91029 Facility Manager PRIOR to start of work.

1.3 Contractor shall coordinate work closely with Contracting Officer or representative, as well as the CE Electrical Shop on all issues pertaining to work phasing, scheduling, planning, and execution (if required).

1.4 The contractor will provide the names of all workers to the building manager and Contracting Officer prior to start of work.

1.5 All workers from the contractor and sub-contractors will be informed on the specific security issues and operating practices of the building and will comply.

1.6 All work will be performed during normal duty hours; weekends or holidays will be coordinated with Contracting Officer and facility manager and may be approved at no additional cost to the Government.

2. LOCATION

2.0 The project site is located on Hurlburt Field, Florida at building(s) 91029.

3. MATERIALS

3.0 Contractor to provide technical data sheets for all equipment and/or materials if providing an “Or Equal” substitute.

4. PROJECT ELEMENTS

4.0 The project will contain, but is not limited to the following elements:

4.1 Demo

4.1.1 The contractor shall be responsible for removal of the existing Synergy Lighting Control System to include:

4.1.2 Two (2) main touch control panels identified on attached drawing as XXX in room 104 and on the main stage at the front of the auditorium.

4.1.3 Two (2) one-button control switches identified on attached drawing as X located at each of the two front entrance doors of the auditorium.

4.1.4 One (1) power supply breaker box identified on attached drawing as XX located in electrical room 117. See attached photos of Synergy box (Image 1) and electrical room (Image 2).

4.2 Dimmer Control Install

4.2.1 The contractor shall provide and install a EchoTouch Dimmer Control System (OR EQUAL) consisting of the following items:

4.2.2 Equipment shall be installed at the same, or approximate location as equipment being removed. Any changes to location shall be coordinated with the facility manager prior to installation.

4.3 Electrical – Power connection

4.3.1 The contractor shall provide and install new relay panel in Electrical Room

Line Item

Item

U/M

QTY

0001 ETS-5 Unison EchoTouch Mk2 Controller with white finish. P/N 7186A1119-5

EA 2

0002 ETS-SBB EchoTouch Surface-Mount Box, Black P/N 7186A1116-4

EA 2

0003 E1001-5 Echo Inspire Button Station with white finish. P/N 7186A1001-5

- 100-240VAC Power Input

- Provides 24VDC Aux Power

-DIN8 Enclosure

EA 2

0004 IQ12 – Sensor IQ Wall Mount panel P/N 7131A1025

3-Phaase 120/208V, 100A; 12 Pole Breaker sub panel with no breakers. 5 – 2x250MCM Main Lugs with option for main breaker.

EA 1

0005 IQ Panel Door 120-12S ML - Door for surface mount 12-circuit MLO panel

P/N 7131A1512

EA 1

0006 IQ SM B20 – Sensor IQ 120V 20A single pole intelligent breaker with relay, include reporting for current, breaker trip and relay state.

P/N CB852-2

EA 12

117 and make all connections.

4.4 System Start-up/Training

4.4.1 The contractor shall ensure dimmer system is operational upon completion of installation.

4.4.2 The contractor shall provide training on system operation and shut-down.

END OF STATEMENT OF WORK