Att3_Conceptual Floor Plan.pdf
PDF 170 KB Posted
- Attached to
- Lome Emergency Operations Center, Togo
- Solicitation number
- W912GB22R0022
- Issued by
-
Department of the Army European Command
About this file
This document contains a pre-solicitation announcement and conceptual floor plan for the proposed construction of a National Emergency Operations Center in Lome, Togo. The U.S. Army Corps of Engineers plans to solicit proposals for a design-build contract to construct a single-story administrative building to serve as the Togo National EOC. The project includes site preparation, construction of the EOC building, backup generator shelter, sentry box, and perimeter security fencing. Site improvements will include extending utility connections and accommodating parking. The conceptual floor plan depicts the proposed layout of the EOC building. The pre-solicitation provides estimated contract value between $500,000-$750,000 and a performance period of approximately 425 days after award. Interested parties are encouraged to submit responses with company information and a SAM registration is required to be eligible for award.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| A.02.10_IEU-22-0003 Sources Sought Questionnaire_Lome Togo_fillable.xlsx | XLSX spreadsheet | |
| A.02.10 IEU-22-0003 Pre SOL_Lome Emergency Ops_Togo.docx | DOCX document | |
| SOW_Togo_011010.pdf | ||
| Section 01 22 00_Operations Center_Lome Togo.docx | DOCX document | |
| Att1_Location Map.pdf | ||
| Att2_Conceptual Site Plan.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
20.5 m²
MAIN ENTRANCE PATIO
30.3 m²
RECEPTION
10.0 m²
PRIVATE OFFICE
27.6 m²
MEDIA ROOM
56.3 m²
MEETING ROOM 2
40.0 m²
BREAK ROOM
29.9 m²
OPEN OFFICE
60.8 m²
MEETING ROOM 1
21.0 m²
INCIDENT MANAGER'S
OFFICE
27.1 m²
COMMANDER'S OFFICE
56.3 m²
OPERATIONS ROOM
33.1 m²
TECHNICAL ROOM FOR
INFORMATION
TECHNOLOGY (IT)
14.5 m²
SERVER ROOM
116B
.0
34.500
13.9 m²
STORAGE
118.9 m²
CORRIDOR
10.0 m²
PRIVATE OFFICE
8.2 m²
TOI. FEMALE
8.2 m²
TOI. MALE
4.0 m²
TOI. & SHOWER
113B
4.0 m²
TOIL. /
DOUCHE
112B
8.2 m²
TOI. & SHOWER
10.0 m²
RESTING ROOM
10.0 m²
RESTING ROOM
5.1 m²
ELECTRICAL ROOM
110B
233 2 2 2
3 3
2 2 2 2 2
3 3
2 2 2
2 2
2 2
3 3
4 4 4
4 4 4
4 4
4 4
4 4
KI
TE
C H
EN
ET
TE
18.6 m²
PATIO
102C
18.6 m²
PATIO
102B
1.000 TYP.
19.5 m²
CORRIDOR
102D
Not Enclosed
GUARD SHACK
(LOCATION SEE SITE
PLAN)
102E
1.650
1.
Roof Overhang 50cm
3.6 m²
JANITOR
102F
1 : 75A-101
1 EOC ONE-STORY FLOOR PLAN
# NOTE
1 CONCRETE APRON, 1.0 m WIDE ALL AROUND
2 SLIDING WINDOW
3 GLASS LAMELLA WINDOW
4 WALL-MOUNTED TELEVISION
5 CEILING-MOUNTED PROJECTOR SCREEN
6 METAL SECURITY DOOR
ATTACHMENT #3: CONCEPTUAL FLOOR PLAN
US Army Corps of Engineers ®
SHEET OF
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
A-101
C O
N C
ET
U
AL
F
LO
O
R P
LA
N
N
AT
IO
N
AL
E
M
ER
G
EN
C Y
O
PE
R
AT
IO
N
S C
EN
TE
R (E
O C
LO
M É, T O
G O
EU
R
O
PE
D
IS
TR
IC
T W
IE
SB
AD
EN
, G
ER
M
AN
Y
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
NOTE: DRAWINGS ARE PROVIDED FOR REFERENCE ONLY.
CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL
EXISTING CONDITIONS. CONTRACTOR IS RESPONSIBLE
FOR PROVIDING A DESIGN THAT MEETS ALL APPLICABLE
CODES AND REQUIREMENTS OF THE SOW.
SCALE = 1:75
0 5 m
N
1 2 43
GUARD SHACK FLOOR PLAN
Note: Movable Furniture Shown, is NOT in the Scope of this Project.
| Sheets |
| A-101 - CONCETUAL FLOOR PLAN |
File details come from the government source that posted it. Updated .