Att3_Conceptual Floor Plan.pdf

PDF 170 KB Posted

Attached to
Lome Emergency Operations Center, Togo
Solicitation number
W912GB22R0022
Issued by

About this file

This document contains a pre-solicitation announcement and conceptual floor plan for the proposed construction of a National Emergency Operations Center in Lome, Togo. The U.S. Army Corps of Engineers plans to solicit proposals for a design-build contract to construct a single-story administrative building to serve as the Togo National EOC. The project includes site preparation, construction of the EOC building, backup generator shelter, sentry box, and perimeter security fencing. Site improvements will include extending utility connections and accommodating parking. The conceptual floor plan depicts the proposed layout of the EOC building. The pre-solicitation provides estimated contract value between $500,000-$750,000 and a performance period of approximately 425 days after award. Interested parties are encouraged to submit responses with company information and a SAM registration is required to be eligible for award.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

20.5 m²

MAIN ENTRANCE PATIO

30.3 m²

RECEPTION

10.0 m²

PRIVATE OFFICE

27.6 m²

MEDIA ROOM

56.3 m²

MEETING ROOM 2

40.0 m²

BREAK ROOM

29.9 m²

OPEN OFFICE

60.8 m²

MEETING ROOM 1

21.0 m²

INCIDENT MANAGER'S

OFFICE

27.1 m²

COMMANDER'S OFFICE

56.3 m²

OPERATIONS ROOM

33.1 m²

TECHNICAL ROOM FOR

INFORMATION

TECHNOLOGY (IT)

14.5 m²

SERVER ROOM

116B

.0

34.500

13.9 m²

STORAGE

118.9 m²

CORRIDOR

10.0 m²

PRIVATE OFFICE

8.2 m²

TOI. FEMALE

8.2 m²

TOI. MALE

4.0 m²

TOI. & SHOWER

113B

4.0 m²

TOIL. /

DOUCHE

112B

8.2 m²

TOI. & SHOWER

10.0 m²

RESTING ROOM

10.0 m²

RESTING ROOM

5.1 m²

ELECTRICAL ROOM

110B

233 2 2 2

3 3

2 2 2 2 2

3 3

2 2 2

2 2

2 2

3 3

4 4 4

4 4 4

4 4

4 4

4 4

KI

TE

C H

EN

ET

TE

18.6 m²

PATIO

102C

18.6 m²

PATIO

102B

1.000 TYP.

19.5 m²

CORRIDOR

102D

Not Enclosed

GUARD SHACK

(LOCATION SEE SITE

PLAN)

102E

1.650

1.

Roof Overhang 50cm

3.6 m²

JANITOR

102F

1 : 75A-101

1 EOC ONE-STORY FLOOR PLAN

# NOTE

1 CONCRETE APRON, 1.0 m WIDE ALL AROUND

2 SLIDING WINDOW

3 GLASS LAMELLA WINDOW

4 WALL-MOUNTED TELEVISION

5 CEILING-MOUNTED PROJECTOR SCREEN

6 METAL SECURITY DOOR

ATTACHMENT #3: CONCEPTUAL FLOOR PLAN

US Army Corps of Engineers ®

SHEET OF

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

A-101

C O

N C

ET

U

AL

F

LO

O

R P

LA

N

N

AT

IO

N

AL

E

M

ER

G

EN

C Y

O

PE

R

AT

IO

N

S C

EN

TE

R (E

O C

LO

M É, T O

G O

EU

R

O

PE

D

IS

TR

IC

T W

IE

SB

AD

EN

, G

ER

M

AN

Y

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

NOTE: DRAWINGS ARE PROVIDED FOR REFERENCE ONLY.

CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL

EXISTING CONDITIONS. CONTRACTOR IS RESPONSIBLE

FOR PROVIDING A DESIGN THAT MEETS ALL APPLICABLE

CODES AND REQUIREMENTS OF THE SOW.

SCALE = 1:75

0 5 m

N

1 2 43

GUARD SHACK FLOOR PLAN

Note: Movable Furniture Shown, is NOT in the Scope of this Project.

Sheets
A-101 - CONCETUAL FLOOR PLAN

File details come from the government source that posted it. Updated .