Att. H - 1631931dwg3of4.pdf
PDF 10 MB Posted
- Solicitation number
- N6247021R0003
About this file
This document provides details on a federal solicitation opportunity. The solicitation number is N6247021R0003 and concerns the construction of an Entry Control Point at Aviano Air Base in Italy. The Naval Facilities Engineering Command within the Department of the Navy is the contracting agency. Responses to the solicitation are due based on the dates and instructions provided in solicitation number N6247021R0003 and its accompanying attachments, which include drawing number 1631931dwg3of4. The opportunity is for the construction services required to build the Entry Control Point at the specified military base in Italy.
View the file
Other files
Show all 49
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E
INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR.
NO.
SHEET
NAVFAC DRAWING
NO.
DES DRW CHK
OF
EPROJECT
NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
Y
E N
G
IN
E E
R
IN
G S
Y S
T E
M C
O M
M A
N D
NAVFAC METRIC DRAWFORM REVISION: 07 AUGUST 2018
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
Y E
N G
IN
E
E R
IN
G
S Y
S T
E M
C O
M M
A N
D
A T
L A
N T
IC
N
O R
F O
L K
V
IR
G
IN
IA
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
A V
IA
N
O A
IR
B
A S
E A
V
IA
N O
, I T
A
LY
A R
E A
A
E N
T R
Y C
O N
T R
O L
P O
IN
T
LET/JSL
DPS
1917 SOUTH 67TH STREET
OMAHA, NE 68106
/6
/2
:2
:5
P M
B
IM
/1
N
A V
F A
C A
D e s ig n A v ia n o
It a ly
/1
-S -G e n e ra l_ v
.r v t
S-001
G E
N E
R A
L S
T R
U C
TU
R
A L
N O
TE
S
NO
TE
G
EN
ER
AL
I S
TR
UT
TU
RA
LI
SKM
14090079
ARA JMH
22 MARCH, 2021
APPROVED BY SCOTT KIBLER
VIA E-MAIL
1631931
N62470-21-C-0003
A T
L A
N T
IC
D
E S
IG
N
A N
D C
O N
S T
R U
C T
IO
N
RICHARD STEPHENS, PE
JTW
GENERAL NOTES
APPLICABLE CODES AND STANDARDS
1. INTERNATIONAL BUILDING CODE 2018.
2. BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE ACI-318-14.
3. MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES ASCE7-16.
4. AMERICAN INSTITUTE OF STEEL CONSTRUCTION AISC STEEL CONSTRUCTION
MANUAL, 14TH ED.
5. STEEL DECK INSTITUTE SPECIFICATIONS AND LOAD TABLES.
6. AISI SPECIFICATION FOR DESIGN OF COLD FORMED STEEL STRUCTURAL
MEMBERS.
7. AMERICAN WELDING SOCIETY (AWS) D1.1, D1.3, D1.4.
8. ASTM MATERIAL STANDARDS AS NOTED.
9. UFC 1-200-01 GENERAL BUILDING REQUIREMENTS
(OCTOBER 2019)
10.UFC 3-301-01 STRUCTURAL ENGINEERING
(OCTOBER 2019)
11.UFC 4-010-01 DOD MINIMUM ANTITERRORISM STANDARDS
FOR BUILDINGS
(DECEMBER 2018, W/ CHANGE 1 AUG 2020)
12.UFC 4-022-01 ENTRY CONTROL FACILITIES ACCESS CONTROL POINTS
(JULY 2017)
13.LAW NO. 1086 DATED 11/5/71 REGARDING REINFORCED CONCRETE AND PRE-
STRESSED REINFORCED CONCRETE STRUCTURES AND STEEL STRUCTURES.
14.SEISMIC DESIGN FOR BUILDINGS - ACT NO 64 DATED 2/2/74
15.DM 17 -01-2018 NEW TECHNICAL NORMS FOR BUILDING CONSTRUCTIONS
16.CIRC. 21 JANUARY 2019 N. 7/C.S.LL.PP.
17.EUROCODE
EXISTING CONDITIONS
1. NOTIFY CONTRACTING OFFICER IMMEDIATELY IF EXISTING CONDITIONS DO
NOT MATCH, OR SEEM IN CONFLICT WITH INFORMATION SHOWN ON THE
DRAWINGS.
GENERAL NOTES
1. THE DRAWINGS REPRESENT THE FINISHED STRUCTURE, NOT THE METHOD
OF CONSTRUCTION. SAFETY AND STRUCTURAL STABILITY DURING
CONSTRUCTION ARE THE SOLE REPSONSIBILITY OF THE CONTRACTOR. THE
CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE
STRUCTURE DURING CONSTRUCTION, INCLUDING BUT NOT LIMITED TO,
BRACING, SHORING, FOR CONSTRUCTION LOADS AND EQUIPMENT, ETC.
2. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH THE
ARCHITECTURAL, MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR
LOCATION AND SIZE OF OPENINGS, BLOCK OUTS, FLOOR DEPRESSIONS,
CURBS, DIMENSIONS, ETC. NOT INDICATED ON THE STRUCTURAL DRAWINGS.
THE LOCATION AND SIZE OF MECHANICAL AND ELECTRICAL OPENINGS IN
SLABS, WALLS AND DECKS SHALL BE COORDINATED BY THE CONTRACTOR.
PROVIDE ALL ADDITIONAL FRAMING OR REINFORCING TO ACCOMMODATE
OPENINGS AS REQUIRED BY THE APPLICABLE STANDARD DETAILS, SECTIONS
AND NOTES AS SHOWN ON THE STRUCTURAL DRAWINGS.
3. THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND ELEVATIONS
OF EXISTING CONSTRUCTION AS REQUIRED TO COORDINATE NEW
CONSTRUCTION. SUBMIT REQUIRED CHANGES FOR APPROVAL.
4. CONTRACTOR IS TO ESTABLISH AND VERIFY EMBEDS AND INSERTS ITEMS TO
BE INSTALLED BY OTHER TRADES PRIOR TO SUBMITTAL OF SHOP DRAWINGS
AND CONSTRUCTION.
5. CONSTRUCTION MATERIAL AND EQUIPMENT PLACED ON FRAMED
CONSTRUCTION SHALL BE SUCH THAT THE LOAD DOES NOT EXCEED THE
DESIGN LIVE LOAD OF THE CONSTRUCTIONS. PROVIDE SHORING OF
CONSTRUCTIONS WHERE NECESSARY FOR THE LOADS.
6. DETAILS AND SECTIONS THAT ARE NOTED AS “TYP” ON DETAIL TITLES ARE TO
BE APPLIED TO THE PROJECT CONSTRUCTION AS GENERAL CONSTRUCTION
METHODS UNLESS NOTED OTHERWISE. THESE DETAILS ARE NOT CUT AT ALL
LOCATIONS THEY OCCUR AND MAY BE NOT CUT AT ALL.
7. CONTRACTOR TO SUBMIT FOR REVIEW ALL EQUIPMENT SIZES, OPERATING
WEIGHTS, VIBRATIONAL FORCES, SUPPORTED LOCATIONS, ALONG WITH ANY
FLOOR OPENINGS, NOTCHES, AND RECESSED REQUIRED BY SUCH
EQUIPMENT. CONCRETE SUPPORT PADS AND / OR FRAMING REQUIRED TO
SUPPORT SAID EQUIPMENT SHALL NOT BE FABRICATED AND PLACED UNTIL
THE CONCRETE SUPPORT PADS AND / OR FRAMING IS APPROVED TO
SUPPORT THE EQUIPMENT.
BUILDING OCCUPANCY CATEGORY – RISK FACTOR
1. RISK FACTOR: II
SNOW LOAD
1. GATEHOUSE AND SEARCH OFFICE
a. SNOW LOADS IN ACCORDANCE WITH THE BUILDING CODE LISTED ABOVE
b. EXPOSURE FACTOR, CE: 1.0
c. SNOW LOAD IMPORTANCE FACTOR, IS: 1.0
d. THERMAL FACTOR, CT: 1.0
e. GROUND SNOW LOAD, PG: 1.68 kPa
f. RAIN-ON-SNOW: 0 kPa
g. FLAT ROOF SNOW LOAD, PF: 1.2 kPa
2. CANOPY AND METAL BUILDINGS
a. SNOW LOADS IN ACCORDANCE WITH THE BUILDING CODE LISTED ABOVE.
b. EXPOSURE FACTOR, CE: 1.0
c. SNOW LOAD IMPORTANCE FACTOR, IS: 1.0
d. THERMAL FACTOR, CT: 1.2
e. GROUND SNOW LOAD, PG: 1.68 kPa
f. RAIN-ON-SNOW: 0 kPa
g. FLAT ROOF SNOW LOAD, PF: 1.40kPa
LIVE LOAD ON FLOOR
1. OFFICE: 3.0 kPa
2. MECHANICAL: 6.0 kPa
3. ELECTRICAL: 6.0 kPa
4. PUBLIC ROOMS, LOBBIES, FIRST FLOOR CORRIDORS: 4.8 kPa
5. STORAGE: 6.0 kPa
6. GUARD HOUSE 3.6 kPa
LIVE LOAD ON ROOF 1.00 kPa & SOLAR PANEL
LOADS
WIND LOAD
1. WIND LOADS IN ACCORDANCE WITH THE BUILDING CODE LISTED ABOVE.
2. BASIC WIND SPEED- (3 SECOND GUST)- ULTIMATE: 148km/h
3. EXPOSURE CATEGORY: C
4. INTERNAL PRESSURE COEFFICIENT: 0.18
WIND LOAD (ITALIAN CODE)
1. REFERENCE WIND SPEED: vb=25 m/s
2. EXPOSURE CATEGORY: III
3. REFERENCE KINETIC PRESSURE: 0.39 kPa
4. DYNAMIC COEFFICIENT: cd=1.0
SEISMIC LOAD
1. SEISMIC LOADS IN ACCORDANCE WITH THE BUILDING CODE LISTED ABOVE
2. IMPORTANCE FACTOR, IE: 1.0
3. SPECTRAL RESPONSE ACCELERATIONS, SS: 1.25G
4. SPECTRAL RESPONSE ACCELERATIONS, S1: 0.5G
5. SEARCH OFFICE AND GATEHOUSE:
a. SITE CLASS: C
b. SPECTRAL RESPONSE COEFFICIENT, SDS: 0.833
c. SPECTRAL RESPONSE COEFFICIENT, SD1: 0.5
d. SEISMIC DESIGN CATEGORY: D
e. SEISMIC RESPONSE COEFFICIENT, CS: 0.167
f. SEISMIC FORCE RESISTING SYSTEM: SPECIAL REINFORCED
CONCRETE SHEAR
WALLS
6. ID CHECK CANOPY:
a. SITE CLASS: C
b. SPECTRAL RESPONSE COEFFICIENT, SDS: 0.833
c. SPECTRAL RESPONSE COEFFICIENT, SD1: 0.5
d. SEISMIC DESIGN CATEGORY: D
e. SEISMIC RESPONSE COEFFICIENT, CS: 0.185
f. SEISMIC FORCE RESISTING SYSTEM: ORDINARY STEEL
MOMENT FRAMES
7. RESPONSE MODIFICATION FACTOR, R:
a. GATEHOUSE AND SEARCH OFFICE 5
b. CANOPY 3.5
8. ANALYSIS PROCEDURE: EQUIVALENT LATERAL
FORCE
SEISMIC LOADS (ITALIAN CODE)
1. LATITUDE: 46.07
2. LONGITUDE: 12.58
3. SITE CLASS: B
4. SERVICEABILITY LIFE: Vn=50 years
5. OCCUPANCY CLASS: II
6. OCCUPANCY FACTOR: Cu=1.0
7. REFERENCE LIFE: 50 years
8. SOIL ACCELERATION PARAMETERS SLV: ag/g=0.2425 F0=2.42 Tc=0.33
9. RETURN PERIOD SLV: 475 years
NOTE GENERALI
NORMATIVA E STANDARD APPLICABILI
1. NORME INTERNAZIONALI DELLE COSTRUZIONI 2018
2. REQUISITI DI PROGETTO PER CALCESTRUZZO ARMATO ACI-318-14
3. CARICHI MINIMI DI PROGETTO PER EDIFICI ED ALTRE STRUTTURE ASCE7-16.
4. ISTITUTO AMERICANO DI COSTRUZIONI IN ACCIAIO AISC MANUALE DI
COSTRUZIONI IN ACCIAIO, 14a EDIZIONE
5. SPECIFICHE E TABELLE DI CARICO ISTITUTO DI LAMIERE DI ACCIAIO
6. AISI SPECIFICHE PER IL PROGETTO DI ELEMENTI STRUTTURALI DI ACCIAIO
PROFILATI A FREDDO.
7. SOCIETA' AMERICANA SALDATURE (AWS) D1.1, D1.3, D1.4.
8. MATERIALI STANDARD ASTM COME INDICATO.
9. UFC 1-200-01 REQUISITI GENERALI DELLE STRUTTURE
(OTTOBRE 2019)
10.UFC 3-301-01 INGEGNERIA STRUTTURALE
(OTTOBRE 2019)
11.UFC 4-010-01 STANDARD MINIMI ANTITERRORISMO PER EDIFICI
(DICEMBRE 2018 CON CAMBIO 1 AGOSTO 2020)
12.UFC 4-022-01 STRUTTURE DI CONTROLLO DI INGRESSO PUNTI DI
CONTROLLO ACCESSO (LUGLIO 2017)
13.LEGGE NO. 1086 5/11/1971 NORME TECNICHE PER IL CALCOLO L'ESECUZIONE
E IL COLLAUDO DI STRUTTURE IN CALCESTRUZZO ARMATO NORMALE E
PRECOMPRESSO E DI STRUTTURE IN ACCIAIO.
14.NORME TECNICHE PER LE COSTRUZIONI IN ZONA SISMICA- LEGGE 64 -
2/2/1974)
15.DM 17-01-2018 AGGIORNAMENTO ALLE NORME TECNICHE PER LE
COSTRUZIONI.
16.CIRC. 21/2/2019 ISTRUZIONI PER L'APPLICAZIONE DELLE NUOVE NORME
TECNICHE PER LE COSTRUZIONI
17.EUROCODICI
CONDIZIONI ESISTENTI
1. NOTIFICARE L'UFFICIALE CONTRAENTE IMMEDIATAMENTE SE LE CONDIZIONI
NON CORRISPONDONO O APPAIONO IN CONFLITTO CON LE INFORMAZIONI
INDICATE NEI DISEGNI.
NOTE GENERALI
1. I DISEGNI RAPPRESENTANO LA STRUTTURA FINITA, NON IL METODO DI
COSTRUZIONE. LA SICUREZZA E LA STABILITA' DURANTE LA COSTRUZIONE
SARANNO RESPONSABILITA' UNICA DELL'APPALTATORE. L'APPALTATORE
DOVRA' PREDISPORRE TUTTE LE MISURE NECESSARIE A PROTEGGERE LA
STRUTTURA DURANTE LA COSTRUZIONE, INCLUSE MA NON LIMITATE A
CONTROVENTATURE, SUPPORTI PER CARICHI DA COSTRUZIONE, IMPIANTI,
ECC.
2. LE TAVOLE STRUTTURALI DOVRANNO ESSERE USATE INSIEME ALLE TAVOLE
ARCHITETTONICHE, MECCANICHE, ELETTRICHE E IDRAULICHE PER
POSIZIONE E DIMENSIONI DI APERTURE, CHIUSURE, DEPRESSIONI SOLETTE,
BORDI, DIMENSIONI ECC. NON INDICATE NELLE TAVOLE STRUTTURALI.
POSIZIONE E DIMENSIONI DI FORI MECCANICI ED ELETTRICI IN SOLAI, PARETI
E SOLETTE SARA' COORDINATA CON L'APPALTATORE. FORNIRE TUTTI I TELAI
E ARMATURE ADDIZIONALI PER REALIZZARE I FORI COME RICHIESTO DAI
DETTAGLI STANDARD APPLICABILI, SEZIONI E NOTE, INDICATI NELLE TAVOLE
STRUTTURALI.
3. L'APPALTATORE DOVRA' VERIFICARE IN CANTIERE TUTTE LE DIMENSIONI E
QUOTE DELLA COSTRUZIONE ESISTENTE COME RICHIESTO PER COORDINARE
LA NUOVA COSTRUZIONE. SOTTOMETTERE PER APPROVAZIONE I CAMBI
NECESSARI.
4. L'APPALTATORE DOVRA' STABILIRE E VERIFICARE GLI INSERTI E GLI INCASSI
PER GLI ELEMENTI DA ISTALLARE SECONDO LE ALTRE DISCIPLINE PRIMA
DELLA SOTTOMISSIONE DEGLI SHOP DRAWINGS E DELLA COSTRUZIONE.
5. I MATERIALI DI COSTRUZIONE E GLI IMPIANTI POSIZIONATI SU COSTRUZIONI
INTELAIATE SARANNO TALI DA NON ECCEDERE IL CARICO ACCIDENTALE DI
PROGETTO DELLE COSTRUZIONI. PREDISPORRE PUNTELLAMENTI DELLE
STRUTTURE LADDOVE NECESSARIO PER I CARICHI.
6. DETTAGLI E SEZIONI CHE SONO INDICATE CON "TYP" SUI TITOLI DEL
DETTAGLIO SARANNO DA APPLICARE ALLA COSTRUZIONE DEL PROGETTO
COME METODI GENERALI DI COSTRUZIONE SALVO DIVERSA INDICAZIONE.
TALI DETTAGLI NON SONO INDICATI A TUTTE LE POSIZIONI DOVE SI TROVANO
E POTREBBERO NON TROVARSI AFFATTO.
7. L'APPALTATORE DOVRA' SOTTOMETTERE PER REVISIONE TUTTE LE
DIMENSIONI, CARICHI AGENTI, FORZE DI VIBRAZIONE, POSIZIONI DEI
SUPPORTI DEGLI IMPIANTI, INSIEME A QUALSIASI FORO NEI SOLAI, INTAGLIO E
RIENTRANZA RICHIESTA DA TALE IMPIANTO. I BASAMENTI IN CLS DI
SUPPORTO E/O INTELAIATURE NECESSARIE PER IL SUPPORTO NON
DOVRANNO ESSERE FABBRICATE E POSIZIONATA FINO A CHE I BASAMENTI DI
CLS E/O INTELAIATURE SIANO STATE APPROVATE PER SOSTENERE GLI
IMPIANTI.
BUILDING OCCUPANCY CATEGORY – RISK FACTOR
1. FATTORE DI RISCHIO: II
CARICO DA NEVE
1. CORPO DI GUARDIA E UFFICIO CONTROLLI
a. CARICHI DA NEVE IN ACCORDO CON LE NORMATIVE DI COSTRUZIONE
SUINDICATE.
b. ATTORE DI ESPOSIZIONE CE 1.0
c. FATTORE DI IMPORTANZA CARICO DA NEVE, IS: 1.0
d. FATTORE TERMICO, CT: 1.0
e. CARICO DA NEVE AL SUOLO, PG 1.68 kPa
f. PIOGGIA SU NEVE: 0 kPa
g. CARICO DA NEVE SU COPERTURA, PF: 1.2 kPa
2. EDIFICI METALLICI E PENSILINE
a. CARICHI DA NEVE IN ACCORDO CON LE NORMATIVE DI COSTRUZIONE
SUINDICATE.
b. FATTORE DI ESPOSIZIONE CE 1.0
c. FATTORE DI IMPORTANZA CARICO DA NEVE, IS: 1.0
d. FATTORE TERMICO, CT: 1.2
e. CARICO DA NEVE AL SUOLO, PG 1.68 kPa
f. PIOGGIA SU NEVE: 0 kPa
g. CARICO DA NEVE SU COPERTURA, PF: 1.4 kPa
CARICHI ACCIDENTALI SU SOLAI
1. UFFICI 3.0 kPa
2. LOCALI MECCANICI 6.0 kPa
3. LOCALI ELETTRICI 6.0 kPa
4. LOCALI PUBBLICI, HALL, CORRIDOI PIANO TERRA 4.8 kPa
5. MAGAZZINI 6.0 kPa
6. CORPO DI GUARDIA 3.6 kPa
CARICHI ACCIDENTALI SU COPERTURA 1.0 kPa E CARICHI
PANNELLI SOLARI
CARICHI DA VENTO
1. CARICHI DA VENTO IN ACCORDO CON LE NORMATIVE SUINDICATE.
2. VELOCITA' VENTO DI BASE -(RAFFICA 3-SEC) ULTIMO: 148km/h
3. CATEGORIA DI ESPOSIZIONE: C
4. COEFFICIENTE DI PRESSIONE INTERNA: 0.18
CARICHI DA VENTO (NORME ITALIANE)
1. VELOCITA' VENTO DI RIFERIMENTO vb=25m/s
2. CATEGORIA DI ESPOSIZIONE III
3. PRESSIONE CINETICA DI RIFERIMENTO 0.39 kPa
4. COEFFICIENTE DINAMICO cd=1.0
CARICHI SISMICI
1. CARICHI SISMICI IN ACCORDO CON LE NORMATIVE SUINDICATE
2. FATTORE DI IMPORTANZA, IE: 1.0
3. ACCELERAZIONE SPETTRALE, SS: 1.25G
4 ACCELERAZIONE SPETTRALE, S1: 0.5G
5. UFFICIO CONTROLLI E CORPO DI GUARDIA
a. CATEGORIA TERRENO: C
b. COEFFICIENTE DI RISPOSTA SPETTRALE, SDS 0.833
c. COEFFICIENTE DI RISPOSTA SPETTRALE, SD1 0.5
d. CATEGORIA SISMICA DI PROGETTO D
e. COEFFICIENTE DI RISPOSTA SISMICO, CS 0.167
f. SISTEMA RESISTENTE FORZE SISMICHE PARETI SPECIALI A
TAGLIO IN CLS ARMATO
6. PENSILINA CONTROLLO PASS
a. CATEGORIA TERRENO: C
b. COEFFICIENTE DI RISPOSTA SPETTRALE, SDS 0.833
c. COEFFICIENTE DI RISPOSTA SPETTRALE, SD1 0.5
d. CATEGORIA SISMICA DI PROGETTO D
e. COEFFICIENTE DI RISPOSTA SISMICO, CS 0.185
f. SISTEMA RESISTENTE FORZE SISMICHE TELAIO ORDINARIO IN
ACCIAIO A MOMENTO
7. FATTORE DI RISPOSTA, R:
a. CORPO DI GUARDIA E UFFICIO CONTROLLI 5
b. PENSILINA 3.5
8 . PROCEDURA FORZA LATERALE
EQUIVALENTE
CARICHI SISMICI (NORMATIVA ITALIANA)
1. LATITUDINE: 46.07
2. LONGITUDINE: 12.58
3. CATEGORIA DI SUOLO B
4. VITA NOMINALE: Vn=50 anni
5. CLASSE D'USO: II
6. FATTORE D'USO: Cu=1.0
7. VITA DI RIFERIMENTO: 50 anni
8. COEFF. DI ACCELERAZIONE AL SUOLO IN SLV ag/g=0.2425 F0=2.42 Tc=0.33
9. PERIODO DI RITORNO IN SLV 475 anni
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E
INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR.
NO.
SHEET
NAVFAC DRAWING
NO.
DES DRW CHK
OF
EPROJECT
NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
Y
E N
G
IN
E E
R
IN
G S
Y S
T E
M C
O M
M A
N D
NAVFAC METRIC DRAWFORM REVISION: 07 AUGUST 2018
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
Y E
N G
IN
E
E R
IN
G
S Y
S T
E M
C O
M M
A N
D
A T
L A
N T
IC
N
O R
F O
L K
V
IR
G
IN
IA
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
A V
IA
N
O A
IR
B
A S
E A
V
IA
N O
, I T
A
LY
A R
E A
A
E N
T R
Y C
O N
T R
O L
P O
IN
T
LET/JSL
DPS
1917 SOUTH 67TH STREET
OMAHA, NE 68106
/6
/2
:2
:5
P M
B
IM
/1
N
A V
F A
C A
D e s ig n A v ia n o
It a ly
/1
-S -G e n e ra l_ v
.r v t
S-002
G E
N E
R A
L S
T R
U C
TU
R
A L
N O
TE
S
NO
TE
G
EN
ER
AL
I S
TR
UT
TU
RA
LI
SKM
14090080
ARA JMH
22 MARCH, 2021
APPROVED BY SCOTT KIBLER
VIA E-MAIL
1631931
N62470-21-C-0003
A T
L A
N T
IC
D
E S
IG
N
A N
D C
O N
S T
R U
C T
IO
N
RICHARD STEPHENS, PE
JTW
GENERAL NOTES
STEEL DECK:
1. THE DESIGN, FABRICATION, AND ERECTION OF METAL DECKING SHALL BE IN
ACCORDANCE WITH THE CURRENT EDITION OF THE SDI SPECIFICATIONS AND
THE SDI DIAPHRAGM MANUAL.
2. STEEL ROOF DECK IS 55mm DEEP X 0.8mm THICK WIDE RIB METAL DECK AS
SHOWN ON THE PLANS DESIGNED FOR THE LIVE LOAD GIVEN ABOVE AND 0.6
kPa DEAD LOAD. MINIMUM SECTION PROPERTIES ARE AS FOLLOWS:
Jy = 60.12 cm4/m, We,inf = 21.86 cm3/m, We,sup = 21.86 cm3/m, Fy = 345 MPa, MINIMUM.
3. STEEL ROOF DECK IS TO BE A STRUCTURAL DIAPHRAGM AND SHALL BE
CONNECTED TO THE STRUCTURE AS SHOWN ON DRAWINGS.
4. SUSPENDED CEILINGS, LIGHT FIXTURES, DUCTS, AND OTHER UTILITIES SHALL
NOT BE SUPPORTED FROM THE STEEL DECK.
STRUCTURAL STEEL
1. STRUCTURAL STEEL DESIGN PROPERTIES:
WIDE FLANGE AND TEE SHAPES –
UNI 5398, UNI 5397 CLASSES
S355 Fy= 355 MPa
ANGLES, CHANNELS AND PLATES –
UNI 5398, UNI 5397 CLASSES
S275 Fy= 275 MPa
STEEL PIPE – UNI 7811 CLASSES
S355 Fy= 355 MPa
COLD-FORMED HOLLOW STRUCTURAL SECTIONS –
UNI EN 10219 CLASSES
S235 Fy= 235 MPa S275 Fy= 275 MPa S355 Fy= 355 MPa
COLD-FORMED HOLLOW STRUCTURAL PIPE –
UNI EN 10219 CLASSES
S235 Fy= 235 MPa S275 Fy= 275 MPa S355 Fy= 355 MPa STAINLESS STEEL Fy= 230 MPa
BOLTS – EN 14399 CLASSES
6.8 Fy= 600 MPa
8.8 Fy= 800 MPa
10.9 Fy= 1000 MPa
ANCHOR RODS – CLASSES
S275 Fy= 275 MPa
LIGHT GAGE STEEL STUDS/JOIST – CLASSES
S235 Fy= 235 MPa S275 Fy= 275 MPa S355 Fy= 355 MPa
2. ALL WELDS AND WELDING PROCEDURES SHALL BE PERFORMED IN
ACCORDANCE WITH APPLICABLE PROVISIONS OF AISC AND AWS WELDING
PROCEDURES AND CODES OUTLINED IN THE SPECIFICATION. ALL WELDS
SHALL BE MADE WITH E-70XX ELECTRODES AND IN ACCORDANCE WITH AWS
FOR METAL ALLOY BEING WELDED UNLESS NOTED OTHERWISE.
3. WHEN FILLET WELDS SIZES ARE NOT INDICATED, PROVIDE MINIMUM WELD
SIZE IN ACCORDANCE WITH AISC SPECIFICATIONS, TABLE J2.4. OR 5mm, WHICHEVER IS GREATER.
4. ALL GROOVE WELDS INDICATED ON THE PLANS AND SECTIONS SHALL BE
COMPLETE JOINT PENETRATION WELDS (CJP) UNLESS SPECIFICALLY
INDICATED TO BE PARTIAL PENETRATION WELDS.
5. DIMENSIONS TO CENTERLINE OF COLUMNS AND BEAMS, TOP SURFACES OF
BEAMS AND TUBES AND BACKS OF CHANNELS AND ANGLES UNLESS NOTED
OTHERWISE.
6. ALL FIELD BOLTED CONNECTIONS SHALL BE MADE WITH M20 EN 14399
CLASSES 6.8, 8.8, 10.9 BOLTS, UNLESS NOTED OTHERWISE. ALL FIELD BOLTED
CONNECTIONS SHALL BE SNUG TIGHTENED UNLESS INDICATED AS
PRETENSIONED OR SLIP CRITICAL. PRETENSIONED AND SLIP CRITICAL
CONNECTIONS SHALL BE TIGHTENED USING DIRECT TENSION INDICATORS.
INSTALL HIGH STRENGTH BOLTS ACCORDING TO RCSC’S “SPECIFICATION FOR
STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS” FOR THE TYPE OF
JOINT SPECIFIED.
7. DOUBLE ANGLE MEMBERS SHALL HAVE INTERMITTENT FILLER PLATES AS
REQUIRED BY SECTION E6 OF THE AISC MANUAL OF STEEL CONSTRUCTION.
SOILS INVESTIGATION:
1. SOILS INVESTIGATION WAS MADE BY: GOLDER ASSOCIATES S.R.I.
2. PROJECT NO.: N62742-D-0004
3. DATED: JULY 2020
4. ALLOWABLE BEARING PRESSURE:
a. SEARCH OFFICE AND GATE HOUSE: 191 kN/m2
b. ID CHECK CANOPY: 191 kN/m2
5. SOIL EFFECTIVE UNIT WEIGHT: 17202 kN/m3
6. FRICTION ANGLE: 38°
CONCRETE NOTES
1. CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF
ACI 301 AND ACI 318.
2. REINFORCING STEEL SHALL BE B450C, GRADE 450. REINFORCING STEEL TO
BE WELDED SHALL BE B450C, GRADE 450 .
3. CONCRETE COVER REQUIREMENTS FOR REINFORCEMENT UNLESS NOTED
OTHERWISE ON THE DETAILS OR SECTIONS:
CONCRETE CAST AND PERMANENTLY EXPOSED TO EARTH: 75mm
CONCRETE EXPOSED TO EARTH OR WEATHER:
20mm BARS AND LARGER 50mm 12m BARS AND SMALLER 40mm
CONCRETE NOT EXPOSED TO EARTH OR WEATHER:
SLABS 40mm WALLS 50mm
4. REINFORCING BAR SPLICES SHALL BE IN ACCORDANCE WITH THE
REQUIREMENTS OF ACI 318 AND THE REINFORCING SPLICE LENGTHS
SCHEDULE ON THE DRAWINGS.
5. CAST-IN-PLACE CONCRETE TO BE CLASS C35/45:
LOCATION 28-DAY F’C AIR MAX W/C MAX SLUMP
FOOTINGS/
FOUNDATION WALLS 35 MPa 6%+/-1% 0.45 100mm SLABS 35 MPa - 0.40 100mm EXTERIOR CONCRETE 35 MPa 6%+/-1% 0.45 100mm
6. ALL REINFORCEMENT FOR CAST-IN-PLACE CONCRETE SHALL BE
ACCURATELY PLACED, SUPPORTED, TIED AND SECURED INTO PLACE PRIOR
TO PLACING CONCRETE. ALL REBAR DOWELS SHALL BE TIED IN PLACE PRIOR
TO CONCRETE PLACEMENT. REBAR DOWELS SHALL NOT BE EMBEDDED
AFTER CONCRETE PLACEMENT UNLESS INDICATED ON THE DRAWINGS.
7. REFER TO OTHER DISCIPLINE DRAWINGS PRIOR TO CONSTRUCTION FOR
EMBEDDED ITEMS AND PENETRATIONS NOT SHOWN ON THE STRUCTURAL
DRAWINGS AS REQUIRED TO ACCOMMODATE ALL WORK SHOWN OR
SPECIFIED IN THE CONTRACT DOCUMENTS AND OTHERWISE REQUIRED FOR
THE FURNISHING OF A FUNCTIONALLY COMPLETE PROJECT. REINFORCE
AROUND OPENINGS PER STANDARD STRUCTURAL DETAILS UNLESS
OTHERWISE SHOWN.
8. PROVIDE 20mm CHAMFERS AT ALL EXPOSED EDGES. NOT ALL CHAMFERS
MAY BE SHOWN.
9. ANCHOR BOLTS NOT SPECIFIED BY THE CONTRACT DRAWINGS SHALL BE
DESIGNED AND CERTIFIED BY A REGISTERED PROFESSIONAL ENGINEER,
RETAINED BY THE CONTRACTOR IN ACCORDANCE WITH THE APPLICABLE
PROJECT AND CODE REQUIREMENTS. SUBMIT AS A SHOP DRAWING FOR
REVIEW AND APPROVAL BY THE CONTRACTING OFFICER. COORDINATE
LOCATION, SIZE AND EMBEDMENT PRIOR TO CASTING CONCRETE.
10.ALL CAST-IN-PLACE AND POST-INSTALLED ANCHORS INDICATED IN THE
STRUCTURAL DOCUMENTS SHALL COMPLY WITH APPENDIX D OF ACI 318 AND
CHAPTER 19 OF THE IBC. ALL EXPANSION AND ADHESIVE ANCHORS SHALL
HAVE AN ICC REPORT SHOWING EQUIVALENT LOAD CAPACITY. SUBMIT AND
INSTALL PER THE ICC EVALUATION REPORT.
11.PRIOR TO INSTALLING POST INSTALLED ANCHORS INTO CONCRETE, THE
CONTRACTOR SHALL LOCATE REINFORCING. DO NOT DAMAGE CONCRETE
REINFORCING. ABSOLUTELY NO WELDING OF REINFORCING BARS OR
TORCHING TO BEND REINFORCING BARS SHALL BE ALLOWED WITHOUT
SPECIFIC APPROVAL FROM THE CONTRACTING OFFICER.
NOTE GENERALI
INDAGINI GEOGNOSTICHE:
1. LE INDAGINI GEOGNOSTICHE EFFETTUATE DA: GOLDER ASSOCIATES SRL
2. PROGETTO NO. N62742-D-0004
3. DATATO: LUGLIO 2020
4. CAPACITA' PORTANTE:
a. UFFICIO CONTROLLI E CORPO DI GUARDIA: 191 kN/m2
b. PENSILINA CONTROLLO PASS: 191 kN/m2
5. PESO SPECIFICO EFFICACE TERRENO 17202 kN/m3
6. ANGOLO D'ATTRITO 38°
NOTE DEL CALCESTRUZZO
1. I LAVORI IN CALCESTRUZZO SARANNO IN ACCORDO AI REQUISITI DI ACI 301 E
ACI 318.
2. LE ARMATURE DI ACCIAIO SARANNO B450C. ACCIAIO D'ARMATURA DA
SALDARE SARA' B450C.
3. I REQUISITI DI COPRIFERRO PER ARMATURA SALVO DIVERSA INDICAZIONE
SUI DETTAGLI O SEZIONI:
CLS GETTATO E PERMANENTEMENTE ESPOSTO CONTRO TERRA: 75mm
CALCESTRUZZO ESPOSTO AL TERRENO O ALLE INTEMPERIE:
BARRE 20mm O MAGGIORI 50mm BARRE 12mm O MINORI 40mm
CALCESTRUZZO NON ESPOSTO AL TERRENO O INTEMPERIE:
SOLAI 40mm PARETI 50mm
4. LE SOVRAPPOSIZIONI DI ARMATURE SARANNO IN ACCORDO CON I REQUISITI
DI ACI 318 E LE TABELLE DI LUNGHEZZE DI SOVRAPPOSIZIONE SUI DISEGNI.
5. CALCESTRUZZO GETTATO IN OPERA SARA' CLASSE C35/45:
POSIZIONE f'c 28-gg ARIA RAPP. A/C MAX SLUMP
MAX
PLINTI/
FOND. PARETI 35 MPa 6%+/-1% 0.45 100mm SOLETTE 35 MPa - 0.45 100mm CLS ESTERNO 35 MPa 6%+/-1% 0.45 100mm
6. TUTTE LE ARMATURE PER CLS IN OPERA SARANNO POSIZIONATE CON
PRECISIONE, MANTENUTE, LEGATE E ASSICURATE IN POSIZIONE PRIMA DEL
GETTO IN CLS. TUTTE LE BARRE, SPINOTTI NON DOVRANNO ESSERE
INCASSATI DOPO IL GETTO SALVO DIVERSAMENTE INDICATO NEI DISEGNI.
7. FAR RIFERIMENTO ALLE TAVOLE DELLE ALTRE DISCIPLINE PRIMA DELLA
COSTRUZIONE PER ELEMENTI INCASSATI E PENETRAZIONI NON MOSTRATE
SULLE TAVOLE STRUTTURALI COME RICHIESTO PER ACCOMODARE TUTTE LE
LAVORAZIONI MOSTRATE O SPECIFICATE NEI DOCUMENTI DI CONTRATTO E
ALTRIMENTI NECESSARIE PER LA FORNITURA DI UN'OPERA FUNZIONALMENTE
COMPLETA. RINFORZARE INTORNO ALLE APERTURE COME DA DETTAGLI
STRUTTURALI STANDARD SALVO MOSTRATO DIVERSAMENTE.
8. SMUSSARE DI 0mm TUTTI GLI SPIGOLI ESPOSTI. NON TUTTI GLI SMUSSI
POTREBBERO ESSERE MOSTRATI.
9 BULLONI DI ANCORAGGIO NON SPECIFICATI DAI DISEGNI DI CONTRATTO
SARANNO PROGETTATI E CERTIFICATI DA UN INGEGNERE QUALIFICATO
CONTRATTATO DALL'APPALTATORE IN ACCORDO CON I REQUISITI NORMATIVI
E DI PROGETTO. SOTTOMETTERE COME SHOP DRAWING PER REVISIONE ED
APPROVAZIONE DALL'UFFICIALE CONTRAENTE. COORDINARE POSIZIONE,
DIMENSIONE E INCASSO PRIMA DEL GETTO DI CLS.
10.TUTTI GLI ANCORAGGI POSTI IN OPERA E INSTALLATI SUCCESSIVAMENTE
INDICATI NEI DOCUMENTI STRUTTURALI DOVRANNO ESSERE IN CONFORMITA'
CON L'APPENDICE D DELL'ACI 318 E CAPITOLO 19 DELL'IBC. TUTTI GLI
ANCORAGGI AD ESPANSIONE E ADESIVI DOVRANNO AVERE UN CERTIFICATO
ICC CHE DIMOSTRI UNA CAPACITA' DI CARICO EQUIVALENTE.
11.PRIMA DELL'ISTALLAZIONE DEGLI ANCORAGGI POST-ISTALLATI NEL CLS
L'APPALTATORE DOVRA' INDIVIDUARE L'ARMATURA. NON DANNEGGIARE
L'ARMATURA DEL CLS. NON SARA' ASSOLUTAMENTE PERMESSA LA
SALDATURA DELLE BARRE NE' IL RISCALDAMENTO A CANNELLO PER LA LORO
PIEGATURA SENZA SPECIFICA APPROVAZIONE DELL'UFFICIALE CONTRAENTE.
LAMIERE DI ACCIAIO
1. IL PROGETTO, FABBRICAZIONE ED EREZIONE DELLE LAMIERE SARA' IN
CONFORMITA' CON L' EDIZIONE VIGENTE DELLE SPECIFICHE SDI E DEL
MANUALE DEI DIAFRAMMI SDI.
2. LA LAMIERA DI COPERTURA E' ALTA 55mm X 0.8mm SPESSORE CON
NERVATURE COME MOSTRATO SULLE TAVOLE PROGETTATE PER UN CARICO
ACCIDENTALE SU INDICATO E 0.6 kPa DI CARICO PERMANENTE. LE
PROPRIETA' MINIME DELLA SEZIONE SONO COME DI SEGUITO:
Jy = 60.12 cm4/m, We,inf = 21.86 cm3/m, We,sup = 21.86 cm3/m.
3. LA LAMIERA DOVRA' ESSERE UN DIAFRAMMA COLLEGATO ALLA STRUTTURA
COME MOSTRATO SUI DISEGNI.
4. CONTROSOFFITTI, CORPI ILLUMINANTI, CONDOTTE E ALTRI IMPIANTI NON
DOVRANNO ESSERE MANTENUTI DALLA LAMIERA D'ACCIAIO.
ACCIAIO STRUTTURALE
1. PROPRIETA' DI PROGETTO DELL'ACCIAIO STRUTTURALE:
PROFILI AD H E A T-
UNI 5398, UNI 5397 GRADO
S355 Fy = 355 MPa
PROFILI A L, A C E PIASTRE-
UNI 5398, UNI 5397 GRADO
S275 Fy = 275 MPa
TUBI IN ACCIAIO – UNI 7811 GRADO
S355 Fy = 355 MPa
SEZIONI STRUTTURALI CAVE PROFILATE A FREDDO –
UNI EN 10219 GRADI
S235 Fy = 235 MPa S275 Fy = 275 MPa S355 Fy = 355 MPa
TUBOLARI STRUTTURALI FORMATI A FREDDO –
UNI EN 10219 GRADI
S235 Fy = 235 MPa S275 Fy = 275 MPa S355 Fy = 355 MPa ACCIAIO INOSSIDABILE Fy = 230 MPa
BULLONI – EN 14399 CLASSI
6.8 Fy = 600 MPa
8.8 Fy = 800 MPa
10.9 Fy = 1000 MPa
BARRE DI ANCORAGGIO – GRADI
S275 Fy = 275 MPa
PRESSOPIEGATI IN ACCIAIO MONTANTI/TRAVETTI – GRADI
S235 Fy = 235 MPa S275 Fy = 275 MPa S355 Fy = 355 MPa
2. TUTTE LE SALDATURE E PROCEDURE DI SALTATURA SARANNO EFFETTUATI
IN CONFORMITA' CON LE PRESCRIZIONI APPLICABILI DELL'AISC E DELL'AWS E
NORMATIVE INDICATE IN SPECIFICA. TUTTE LE SALDATURE SARANNO
REALIZZATE CON ELETTRODI E-70XX A IN CONFORMITA' CON AWS PER
ALEAZIONI DI METALLO DA SALDARE SALVO INDICATO DIVERSAMENTE.
3. QUANDO LA DIMENSIONE DELLA SALDATURA A CORDONE D'ANGOLO NON E'
INDICATA, PREDISPORRE LA DIMENSIONE MINIMA SECONDO LE SPECIFICHE
AISC, TABELLA J2.4 OPPURE 5mm, IL VALORE MAGGIORE.
4. TUTTE LE SALDATURE A PENETRAZIONE INDICATE IN PIANTE E SEZIONI
SARANNO A PENETRAZIONE COMPLETA (CJP) SALVO SPECIFICAMENTE
INDICATO COME PENETRAZIONE PARZIALE.
5. LE QUOTATURE SI RITENGONO RISPETTO AGLI ASSI DI PILASTRI E TRAVI,
ALLE SUPERFICI SUPERIORI DI TRAVI E TUBI E FACCE POSTERIORI DI PROFILI
A C E ANGOLARI SALVO DIVERSA INDICAZIONE.
6. TUTTE LE UNIONI IMBULLONATE IN CANTIERE SARANNO REALIZZATE CON
BULLONI M20 EN 14399 CLASSI 6.8, 8.8, 10.9 SALVO INDICATO DIVERSAMENTE.
TUTTE LE UNIONI IMBULLONATE IN CANTIERE SARANNO A SERRAGGIO
NORMALE SALVO INDICATE COME PRECARICATE O A SERRAGGIO
CONTROLLATO. LE UNIONI PRECARICATE O A SERRAGGIO CONTROLLATO
SARANNO REALIZZATE CON RONDELLE DTI. ISTALLARE I BULLONI AD ALTA
RESISTENZA IN ACCORDO ALLE SPECIFICHE PER UNIONI STRUTTURALI DELLA
RCSC USANDO BULLONI ASTM A325 O A490 PER IL TIPO DI UNIONE
SPECIFICATA.
7. ELEMENTI AD ANGOLARI DOPPI SARANNO FORNITI DI PIASTRE DI
IMBOTTITURA INTERMITTENTI COME RICHIESTO DALLA SEZIONE E6 DEL
MANUALE DI CONSTRUZIONI DI ACCIAIO AISC.
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P
W12X26
W12X26
TOF x.x
FRAMING SIZE
DIMENSIONE PROFILO
EXISTING FRAMING SIZE
DIMENSIONE PROFILO ESISTENTE
X
BEAM TO BEAM MOMENT CONNECTION
UNIONE A MOMENTO TRAVE-TRAVE
TOP OF FOUNDATION
QUOTA ESTRADOSSO FONDAZIONE
COLUMN GRID MARK
ETICHETTA LINEA ASSE PILASTRO
BEAM TO HSS COLUMN MOMENT CONNECTION
UNIONE A MOMENTO TRAVE-PILASTRO TUBOLARE
NEW WORK KEY NOTE
NOTA CHIAVE LAVORAZIONE NUOVA
DEMOLITION KEY NOTE
NOTA CHIAVE DEMOLIZIONE
TOC x.x TOP OF CONCRETE
QUOTA ESTRADOSSO CLS
TOS x.x TOP OF STEEL
QUOTA ESTRADOSSO ACCIAIO
TOM x.x TOP OF MASONRY
QUOTA ESTRADOSSO MURATURA
x.x TOP OF SLAB SPOT ELEVATION
QUOTA PUNTUALE ESTRAD. SOLAIO
SPAN DIRECTION OF ROOF DECK
DIREZIONE ORDITURA LAMIERA D' ACCIAIO
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E
INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR.
NO.
SHEET
NAVFAC DRAWING
NO.
DES DRW CHK
OF
EPROJECT
NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
Y
E N
G
IN
E E
R
IN
G S
Y S
T E
M C
O M
M A
N D
NAVFAC METRIC DRAWFORM REVISION: 07 AUGUST 2018
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
Y E
N G
IN
E
E R
IN
G
S Y
S T
E M
C O
M M
A N
D
A T
L A
N T
IC
N
O R
F O
L K
V
IR
G
IN
IA
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
A V
IA
N
O A
IR
B
A S
E A
V
IA
N O
, I T
A
LY
A R
E A
A
E N
T R
Y C
O N
T R
O L
P O
IN
T
LET/JSL
DPS
1917 SOUTH 67TH STREET
OMAHA, NE 68106
/6
/2
:2
:5
P M
B
IM
/1
N
A V
F A
C A
D e s ig n A v ia n o
It a ly
/1
-S -G e n e ra l_ v
.r v t
S-003
G E
N E
R A
L S
T R
U C
TU
R
A L
N O
T E
S A
N D
P
LA
N L
E G
E N
D
NO
TE
G
EN
ER
AL
I S
TR
UT
TU
RA
LI
E
LE
GE
ND
A
DI
T
AV
OL
A
SKM
14090081
ARA JMH
22 MARCH, 2021
APPROVED BY SCOTT KIBLER
VIA E-MAIL
1631931
N62470-21-C-0003
A T
L A
N T
IC
D
E S
IG
N
A N
D C
O N
S T
R U
C T
IO
N
RICHARD STEPHENS, PE
JTW
GENERAL NOTES
LEGEND - LEGENDA
PRE-ENGINEERED METAL CANOPY NOTES CONT'D
10.THE FINAL COLUMN BASE REACTIONS, COLUMN LOCATIONS, ANCHOR ROD
SIZES, AND ANCHOR ROD SPACING SHALL BE SUBMITTED TO THE
CONTRACTING OFFICER FOR REVIEW. ALL FOOTINGS, FOUNDATIONS,
ANCHOR RODS, AND PILASTERS HAVE BEEN DESIGNED BASED ON ASSUMED
LOADINGS AND REACTIONS. FOOTINGS AND ANCHOR RODS SHALL BE
VERIFIED AND CONFIRMED BY THE CONTRACTOR’S STRUCTURAL ENGINEER.
LOAD REACTIONS THAT EXCEED THE REACTIONS LISTED PER THE “COLUMN
BASE REACTIONS” TABLES ON SA501 MAY NECESSITATE FOUNDATION
REDESIGN AND RELOCATIONS OF ANCHOR RODS. IF REDESIGN IS REQUIRED,
THE REDESIGN OF THE FOOTINGS AND ANCHOR RODS SHALL BE DONE AND
PAID FOR BY THE CONTRACTOR. THE FOUNDATION SHOP DRAWINGS SHALL
NOT BE SUBMITTED UNTIL THE PRE-ENGINEERED METAL CANOPY SHOP
DRAWINGS, THE COLUMN BASE REACTIONS, AND THE FOUNDATION
VERIFICATION HAVE BEEN APPROVED.
11.THE METAL CANOPY FRAMES AND ALL EXPOSED STRUCTURAL STEEL SHALL
BE GALVANIZED.
12.SEE CONTRACT SPECIFICATION 13 34 19 FOR ADDITIONAL INFORMATION.
SPECIAL STRUCTURAL INSPECTIONS
1. SPECIAL INSPECTIONS AND TESTS SHALL BE BY AN INDEPENDENT TESTING
AND INSPECTION AGENCY EMPLOYED BY THE CONTRACTOR AND APPROVED
BY THE CONTRACTING OFFICER. TEST AND INSPECTION REPORTS SHALL BE
SUBMITTED FOR REVIEW TO THE CONTRACTING OFFICER.
2. SPECIAL INSPECTIONS AND TESTS SHALL BE PERFORMED DURING
CONSTRUCTION IN ACCORDANCE WITH CHAPTER 17 AND SECTION 110 OF
THE 2018 INTERNATIONAL BUILDING CODE, STATEMENT OF SPECIAL
INSPECTION, SCHEDULE OF SPECIAL INSPECTIONS, AND THE CONTRACT
SPECIFICATIONS. THE CONTRACTOR SHALL NOTIFY AND ACCOMMODATE THE
APPLICABLE INSPECTOR DURING APPROPRIATE PHASES OF THE WORK AS
REQUIRED BY EACH TEST AND INSPECTION.
3. SPECIAL INSPECTION, SEE SPECIFICATION SECTION 01 45 35, SPECIAL
INSPECTIONS, STATEMENT OF SPECIAL INSPECTION, AND THE SCHEDULE OF
SPECIAL INSPECTIONS.
POST INSTALLED ANCHORS
1. POST INSTALLED ANCHORS SHALL ONLY BE USED WHERE SPECIFIED ON THE
CONTRACT DRAWINGS. THE CONTRACTOR SHALL OBTAIN APPROVAL FROM
THE CONTRACTING OFFICER BEFORE INSTALLING POST INSTALLED ANCHORS
FOR MISSING OR MISPLACED CAST-IN-PLACE ANCHORS.
2. CARE SHALL BE TAKEN IN PLACING POST– INSTALLED ANCHORS TO AVOID
CONFLICTS WITH THE EXISTING REBAR. HOLES SHALL BE DRILLED AND
CLEANED IN ACCORDANCE WITH THE MANUFACTURER’S WRITTEN
INSTRUCTIONS.
3. SUBSTITUTION REQUESTS FOR PRODUCTS OTHER THAN THOSE SPECIFIED
BELOW, SHALL BE SUBMITTED BY THE CONTRACTOR TO THE CONTRACTING
OFFICER ALONG WITH CALCULATIONS THAT ARE PREPARED AND SEALED BY
A REGISTERED PROFESSIONAL ENGINEER. THE CALCULATIONS SHALL
DEMONSTRATE THAT THE SUBSTITUTED PRODUCT IS CAPABLE OF ACHIEVING
THE PERTINENT EQUIVALENT DESIGN PERFORMANCE VALUES (MINIMUM)
OF THE SPECIFIED PRODUCT USING THE APPROPRIATE DESIGN PROCEDURE
AND/ OR STANDARDS(S). AS REQUIRED BY THE BUILDING CODE. PRODUCT
ICC-ES REPORTS SHALL BE INCLUDED WITH THE SUBMITTAL PACKAGE.
4. UNLESS NOTED OTHERWISE ON PLANS, ACCEPTABLE CONCRETE ANCHORS
PRODUCTS SHALL BE:
a. MECHANICAL ANCHORS FOR USE IN CRACKED AND UNCRACKED
CONCRETE SHALL HAVE BEEN TESTED AND QUALIFIED FOR USE IN
ACCORDANCE WITH ACI 355.2 AND ICC-ES AC193.
b. ADHESIVE ANCHORS FOR USE IN CRACKED AND UNCRACKED CONCRETE
SHALL HAVE BEEN TESTED AND QUALIFIED FOR USE IN ACCORDANCE
WITH ACI 308.
c. CONCRETE SCREW ANCHORS FOR USE IN CRACKED AND UNCRACKED
CONCRETE SHALL HAVE BEEN TESTED AND QUALIFIED FOR USE IN
ACCORDANCE WITH ACI 355.2 AND ICC-ES AC193.
PRE-ENGINEERED METAL CANOPY NOTES
1. RIGID FRAMES SHALL BE SPACED AS INDICATED ON THE DRAWINGS, BUT
OVERALL DIMENSIONS AND CONSTRUCTION DETAILS MAY VARY TO SUIT
MANUFACTURER’S STANDARD DESIGN.
2. THE CANOPY SHALL BE DESIGNED AND FABRICATED IN ACCORDANCE WITH
THE BUILDING CODE LISTED ABOVE AND CONTRACTOR SPECIFICATIONS.
3. THE DESIGN OF THE ANCHOR ROD SIZES, QUANTITIES AND LOCATIONS AS
WELL AS BASE PLATES SHALL BE CALCULATED FOR A PINNED BASE
SUPPORT.
4. THE DIMENSIONS, TOLERANCES OUTLINED IN THE AWS CODE UNDER
WORKMANSHIP AND TOLERANCES APPLICABLE TO HOT ROLLED UNDER THE
AISC “STANDARD MILL PRACTICE” SECTION SHALL BE REQUIRED IN THE
FABRICATION OF THE STEEL CANOPY FRAMES.
5. THE CANOPY FRAMES SHALL BE DESIGNED FOR A MAXIMUM LATERAL
DEFLECTION OF H/200 AT THE HIGHEST CANOPY EAVE HEIGHT FOR THE
BASIC WIND SPEED AND THE SEISMIC PARAMETERS LISTED ABOVE.
6. A COMPLETE DESIGN ANALYSIS THAT IS STAMPED BY A PROFESSIONAL
LICENSED ENGINEER IN THE STATE WHERE THE PROJECT IS LOCATED SHALL
BE SUBMITTED FOR INFORMATION ONLY. THE DESIGN ANALYSIS SHALL
INCLUDE A LIST OF THE DESIGN LOADS, LOADS TRANSMITTED TO THE
FOUNDATIONS, RIGID FRAME DESIGN, MISC BRACING, ANCHOR ROD SIZES,
ANCHOR ROD LAYOUT, LOCATION OF EMBEDDED ITEMS, AND ERECTION
DRAWINGS.
7. THE CANOPY SHALL BE DESIGNED TO SUPPORT ALL MECHANICAL AND
ELECTRICAL EQUIPMENT. ADDITIONAL GIRTS OR PURLINS SHALL BE PLACED
IN CONVENIENT LOCATIONS FOR ATTACHMENT OF MECHANICAL, ELECTRICAL,
AND SOLAR EQUIPMENT.
8. DESIGN LOADS SHALL CONFORM TO THE LIVE, WIND, AND SEISMIC LOAD
PARAMETERS GIVEN ABOVE AND PER THE CONTRACT SPECIFICATIONS. THE
ROOF DEAD LOAD SHALL INCLUDE SELF WEIGHT PLUS A UNIFORM 1kPa
COLLATERAL LOAD. BUILDING DEAD LOADS ARE WEIGHTS OF THE BUILDING
COMPONENTS. LOAD COMBINATIONS SHALL BE IN ACCORDANCE WITH THE
CODES LISTED ABOVE AND MBMA. THE BUILDING STRESSES SHALL BE BY DM
17-01-2018 AND COMPLY WITH AISC SPECIFICATIONS FOR STRUCTURAL
STEEL STRUCTURES.
9. RIGID FRAME ANCHOR ROD SIZES SHALL BE DESIGNED BY THE METAL
CANOPY MANUFACTURER AND FURNISHED BY THE CONTRACTOR. THE
ANCHOR ROD SIZES AND LAYOUT SHALL BE SUBMITTED FOR INFORMATION
ONLY.
GENERAL NOTES
ANCORAGGI POST-ISTALLATI
1. GLI ANCORAGGI POST-ISTALLATI SARANNO USATI SOLO LADDOVE
SPECIFICATO SUI DISEGNI DI CONTRATTO. L'APPALTATORE DOVRA'
OTTENERE L'APPROVAZIONE DELL'UFFICIALE CONTRAENTE PRIMA DI
INSTALLARE ANCORAGGI POST-ISTALLATI AL POSTO DI ANCORAGGI NEL
GETTO MANCANTI O MAL PREDISPOSTI.
2. L'ISTALLAZIONE DEGLI ANCORAGGI POST-ISTALLATI VA ESEGUITA CON
ATTENZIONE PER EVITARE CONFLITTI CON BARRE DI ARMATURA ESISTENTI. I
FORI SARANNO REALIZZATI E PULITI IN ACCORDO CON LE ISTRUZIONI
FORNITE DAL PRODUTTORE.
3. RICHIESTE DI SOSTITUZIONE CON PRODOTTI DIVERSI DA QUELLI SPECIFICATI
DI SEGUITO DOVRANNO ESSERE SOTTOMESSI DALL'APPALTATORE
ALL'UFFICIALE CONTRAENTE INSIEME AI CALCOLI PREPARATI E TIMBRATI DA
UN INGEGNERE QUALIFICATO ABILITATO. I CALCOLI DOVRANNO DIMOSTRARE
CHE IL PRODOTTO IN SOSTITUZIONE SIA CAPACE DI RAGGIUNGERE VALORI DI
PRESTAZIONE EQUIVALENTI DI PROGETTO A QUELLI (MINIMI) DEL PRODOTTO
SPECIFICATO USANDO LE PROCEDURE DI PROGETTO APPROPRIATE E/O
STANDARD COME RICHIESTO DALLE NORMATIVE DI COSTRUZIONE.
CERTIFICATI ICC-ES DOVRANNO ESSERE INCLUSI NEL PACCHETTO DI
SOTTOMISSIONE.
4. SALVO DIVERSAMENTE INDICATO NELLE TAVOLE, GLI ANCORAGGI IN CLS
ACCETTABILI DOVRANNO ESSERE:
a. ANCORAGGI MECCANICI PER USO IN CLS FESSURATO E NON FESSURATO
CHE SIANO STATI TESTATI E QUALIFICATI PER USO IN CONFORMITA' CON
ACI 355.2 E ICC-ES AC193.
b. ANCORAGGI ADESIVI PER USO IN CLS FESSURATO E NON FESSURATO
CHE SIANO STATI TESTATI E QUALIFICATI PER USO IN CONFORMITA' CON
ACI 308.
c. ANCORAGGI AVVITATI IN CLS PER USO IN CLS FESSURATO E NON
FESSURATO CHE SIANO STATI TESTATI E QUALIFICATI PER USO IN
CONFORMITA' CON ACI 355.2 E ICC-ES AC193.
NOTE SULLE PENSILINE PREFABBRICATE
1. I TELAI RIGIDI SARANNO SPAZIATI COME INDICATO NELLE TAVOLE, MA LE
DIMENSIONI TOTALI E I DETTAGLI DI COSTRUZIONE POTREBBERO VARIARE IN
FUNZIONE DEGLI STANDARD DI PROGETTO DEL PRODUTTORE.
2. LA PENSILINA DOVRA' ESSERE PROGETTATA E FABBRICATA IN CONFORMITA'
CON LE NORMATIVE SU INDICATE E LE SPECIFICHE DELL'APPALTATORE.
3. IL PROGETTO DELLE DIMENSIONI DELLE BARRE DI ANCORAGGIO, QUANTITA' E
POSIZIONI COSI' COME LE PIASTRE DI BASE SARANNO CALCOLATE PER UN
SUPPORTO VINCOLATO A CERNIERA.
4. NELLA FABBRICAZIONE DEI TELAI DI ACCIAIO DELLA PENSILINA SARANNO
RICHIESTE DIMENSIONI, TOLLERANZE INDICATE NELLA NORMATIVA AWS SU
LAVORAZIONI E TOLLERANZE APPLICABILI A PROFILI FORMATI A CALDO
SECONDO LA SEZIONE "PRATICHE STANDARD DI FABBRICAZIONE" DELL' AISC.
5. I TELAI DELLA PENSILINA DOVRANNO ESSERE PROGETTATI CON UNA
DEFORMAZIONE LATERALE MASSIMO DI H/200 AL PUNTO PIU' ALTO
DELL'IMPOSTA DELLA PENSILINA PER UNA VELOCITA' BASE DEL VENTO E I
PARAMETRI SISMICI SU ELENCATI.
6. L'ANALISI PROGETTUALE COMPLETA TIMBRATA DA UN INGEGNERE
QUALIFICATO ABILITATO NELLO STATO DOVE E' UBICATO IL PROGETTO SARA'
SOTTOMESSO SOLO PER INFORMAZIONE. LA RELAZIONE PROGETTUALE
DOVRA' INCLUDERE UNA LISTA DEI CARICHI DI PROGETTO, I CARICHI
TRASMESSI ALLE FONDAZIONI, IL PROGETTO DEL TELAIO RIGIDO,
CONTROVENTI VARI, DIMENSIONI DELLE BARRE DI ANCORAGGIO, LA
DISPOSIZIONE DEGLI ANCORAGGI, POSIZIONE DEGLI ELEMENTI INCASSATI E I
DISEGNI DI MONTAGGIO.
7. LA PENSILINA DOVRA' ESSERE PROGETTATA PER SOSTENERE TUTTI GLI
IMPIANTI MECCANICI ED ELETTRICI. ARCARECCI E TRAVI SECONDARIE
DOVRANNO ESSERE POSIZIONATI IN POSIZIONI CONVENIENTI PER IL
COLLEGAMENTO DEGLI IMPIANTI MECCANICI, ELETTRICI E SOLARI.
8. I CARICHI DI PROGETTO DOVRANNO ESSERE CONFORMI AI PARAMETRI DI
CARICO ACCIDENTALI, DA VENTO E DA SISMA FORNITI PRECEDENTEMENTE E
SECONDO LE SPECIFICHE DI CONTRATTO. IL CARICO PERMANENTE DELLA
COPERTURA DOVRA' INCLUDERE IL PESO PROPRIO PIU' UN CARICO
COLLATERALE UNIFORME DI 1 kPa. I CARICHI PERMANENTI SONO I PESI DEI
COMPONENTI DEL FABBRICATO. LE COMBINAZIONI DI CARICO SARANNO IN
ACCORDO CON LE NORMATIVE SU ELENCATE E MBMA. LE TENSIONI NEL
FABBRICATO SARANNO SECONDO IL DM 17-01-2018 E IN CONFORMITA' CON LE
SPECIFICHE AISC PER STRUTTURE IN ACCIAIO STRUTTURALE.
9. LE DIMENSIONI DELLE BARRE DI ANCORAGGIO SARANNO PROGETTATE DAL
PRODUTTORE DELLA PENSILINA DI METALLO E FORNITE DALL'APPALTATORE.
LE DIMENSIONI DELLE BARRE DI ANCORAGGIO E LA DISTRIBUZIONE SARANNO
SOTTOMESSE SOLO PER INFORMAZIONE.
NOTE SULLA PENSILINA PREFABBRICATA (CONT.)
10.LE REAZIONI FINALI ALLA BASE DEI PILASTRI, LE POSIZIONI DEI PILASTRI, LE
DIMENSIONI DELLE BARRE DI ANCORAGGIO E LA SPAZIATURA DELLE BARRE
DI ANCORAGGIO SARA' SOTTOMESSA ALL'UFFICIALE CONTRAENTE PER
REVISIONE. TUTTI I PLINTI, FONDAZIONI, BARRE DI ANCORAGGIO E
BASAMENTI SARANNO PROGETTATI IN BASE AI CARICHI E LE REAZIONI
IPOTIZZATI. I PLINTI E LE BARRE DI ANCORAGGIO SARANNO VERIFICATE E
CONFERMATE DALL'INGEGNERE STRUTTURISTA DELL'APPALTATORE. LE
REAZIONI CHE ECCEDONO QUELLE ELENCATE NELLE TABELLE "REAZIONI DI
BASE DEI PILASTRI" SU TAVOLA 2S-501 POTREBBERO AVERE BISOGNO DI
UNA REPROGETTAZIONE DELLA FONDAZIONE E RIPOSIZIONAMENTO DELLE
BARRE DI ANCORAGGIO. SE UNA RIPROGETTAZIONE FOSSE NECESSARIA, LA
RIPROGETTAZIONE DELLE FONDAZIONI E DELLE BARRE DI ANCORAGGIO
SARA' EFFETTUATA E PAGATA DALL'APPALTATORE. GLI SHOP DRAWINGS
DELLA FONDAZIONE NON SARANNO SOTTOMESSI FINCHE' NON SIANO STATI
APPROVATI GLI SHOP DRAWINGS DELLA PENSILINA E LE VERIFICHE DELLE
REAZIONI DI BASE E LE FONDAZIONI DEI PILASTRI.
11.I TELAI DELLA PENSILINA METALLICA E TUTTE LE STRUTTURE IN ACCIAIO
ESPOSTE SARANNO ZINCATE.
12.VEDI SPECIFICA DI CONTRATTO 13 34 19 PER INFORMAZIONI AGGIUNTIVE.
SPECIAL STRUCTURAL INSPECTIONS
1. SPECIAL INSPECTIONS AND TESTS SHALL BE BY AN INDEPENDENT TESTING
AND INSPECTION AGENCY EMPLOYED BY THE CONTRACTOR AND APPROVED
BY THE CONTRACTING OFFICER. TEST AND INSPECTION REPORTS SHALL BE
SUBMITTED FOR REVIEW TO THE CONTRACTING OFFICER.
2. SPECIAL INSPECTIONS AND TESTS SHALL BE PERFORMED DURING
CONSTRUCTION IN ACCORDANCE WITH CHAPTER 17 AND SECTION 110 OF
THE 2018 INTERNATIONAL BUILDING CODE, STATEMENT OF SPECIAL
INSPECTION, SCHEDULE OF SPECIAL INSPECTIONS, AND THE CONTRACT
SPECIFICATIONS. THE CONTRACTOR SHALL NOTIFY AND ACCOMMODATE THE
APPLICABLE INSPECTOR DURING APPROPRIATE PHASES OF THE WORK AS
REQUIRED BY EACH TEST AND INSPECTION.
3. SPECIAL INSPECTION, SEE SPECIFICATION SECTION 01 45 35, SPECIAL
INSPECTIONS, STATEMENT OF SPECIAL INSPECTION, AND THE SCHEDULE OF
SPECIAL INSPECTIONS.
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P
NOTES:
1. ALL REBAR SPLICE LENGTHS SHALL BE AS SHOWN UNDER HEADING "VERTICAL" EXCEPT
IF SPLICED BARS ARE HORIZONTAL BARS WITH 300mm OR MORE CONCRETE BELOW.
THEN SPLICE LENGTH SHALL BE AS SHOWN UNDER HEADING "OTHER".
2. AT SPLICES THE BAR SPACING IS THE CENTER TO CENTER DISTANCE BETWEEN
ADJACENT REBARS.
3. ALL SPLICES SHALL BE CONTACT SPLICES AND WIRED TOGETHER.
4. NO WELDED OR MECHANICAL SPLICES ARE PERMITTED UNLESS INDICATED OTHERWISE.
5. UNLESS OTHERWISE SHOWN, SPLICES FOR BOTTOM REINFORCING BARS IN BEAMS AND
SLABS SHALL BE CENTERED OVER THE SUPPORTS. SPLICES FOR TOP REINFORCING
BARS SHALL BE LOCATED ON CENTERLINE OF SPAN.
MINIMUM LAP SPLICE LENGTHS f'c = 35 MPa
BAR
BARRA
LAPS FOR BARS SPACED
GREATER THAN MIN BAR SPACING
SOVRAPPOSIZIONI PER BARRE A
DISTANZA MAGGIORE DEL MINIMO
LAPS FOR BARS SPACED CLOSER
THAN MIN BAR SPACING
SOVRAPPOSIZIONI PER BARRE A
DISTANZA MINORE DEL MINIMO
VERTICAL VERTICALI OTHER ALTRE
* MIN BAR
SPACING
DISTANZA
MIN. TRA
BARRE
Ø10
Ø12
Ø16
Ø20
Ø24
75mm
75mm
100mm
100mm
400mm 450mm
450mm400mm
75mm
500mm 600mm 650mm500mm
600mm 750mm 1250mm900mm
700mm 900mm 1450mm1100mm
1050mm 1400mm 1950mm1500mm
LUNGHEZZE DI SOVRAPPOSIZIONE MINIME f'c=35MPa
VERTICAL VERTICALI OTHER ALTRE
NOTE:
1. TUTTE LE LUNGHEZZE DI SOVRAPPOSIZIONE DELLE BARRE DOVRANNO ESSERE COME INDICATO SOTTO IL TITOLO "VERTICALE" SALVO SE LE BARRE SOVRAPPOSTE SONO ORIZZONTALI CON ALMENO 300mm O PIU' DI CLS AL DI SOTTO. IN QUEL CASO LA LUNGHEZZA DI SOVRAPPOSIZIONE SARA' COME
INDICATO NELLA COLONNA "ALTRE".
2. * NELLE SOVRAPPOSIZIONI LA DISTANZA TRA LE BARRE E' TRA GLI ASSI DI BARRE ADIACENTI.
3. TUTTE LE SOVRAPPOSIZIONI SARANNO IN CONTATTO E LEGATE INSIEME.
4. NON SONO PERMESSE SALDATURE O SOVRAPPOSIZIONI MECCANICHE SALVO INDICATO DIVERSAMENTE.
5. SALVO DIVERSA INDICAZIONE LE SOVRAPPOSIZIONI TRA BARRE DI ARMATURA INFERIORI NELLE TRAVI E
NEI SOLAI SARANNO CENTRATE SUI SUPPORTI. SOVRAPPOSIZIONI PER BARRE SUPERIORI SARANNO
SITUATE NEL CENTRO DELLE CAMPATE.
RECTANGULAR OPENING DETAIL
DETTAGLIO TIPICO FORO RETTANGOLARE
CIRCULAR OPENING DETAIL
DETTAGLIO TIPICO FORO CIRCOLARE
2- Ø16 X 1200mm EACH
FACE TYP 4 LOCATIONS
ADDITIONAL REINF
SEE NOTE 1
CL SYMM ABOUT OPENING
CL SYMM ABOUT OPENING
SIMMETRICO RISPETTO
AL FORO
NOTES:
1. PROVIDE ADDITIONAL REINFORCING THE SAME SIZE AS DISCONTINUOUS
REINFORCEMENT AT OPENING. QUANTITY OF REINFORCING IN EACH
DIRECTION SHALL BE EQUAL TO OR ONE GREATER THAN THE NUMBER OF
DISCONTINUOUS BARS. PLACE 1/2 OF ADDITIONAL REINFORCING BARS
EACH SIDE OF OPENING, PLACE ADDITIONAL REINFORCEMENT AT 75mm OC
(TYPICAL BOTH DIRECTIONS AND ALL LAYERS OF REINFORCEMENT). START
FIRST BAR 50mm CLEAR TO OPENING.
2. EXTEND ADDITIONAL REINFORCING BEYOND EDGE OF OPENING AS SHOWN
ABOVE. ADDITIONAL BARS MAY TERMINATE AT THE END OF THE WALL WITH
A STANDARD HOOK WHERE THE LENGTH OF THE WALL WILL NOT PERMIT
BARS TO EXTEND AS SHOWN ABOVE.
3. TYPICAL WALL OR SLAB REINFORCING NOT SHOWN FOR CLARITY. TERMINATE
TYPICAL REINFORCING 50mm CLEAR TO OPENING.
4. OPENINGS 300mm OR LESS IN SLABS AND WALLS, NO EXTRA REBARS ARE
REQUIRED UNLESS SHOWN OTHERWISE. TYPICAL REINFORCING SHALL BE
RESPACED (NOT CUT) TO ALLOW FOR OPENINGS TO BE MADE.
5. UNLESS SHOWN OTHERWISE ON DRAWINGS, PROVIDE EXTRA REINFORCING
AROUND OPENINGS AS SHOWN AND INDICATED ABOVE.
6. PROVIDE ADDITIONAL DOWELS PER NOTE 1 ABOVE FOR ALL OPENINGS NEAR
THE FLOOR SLAB, BASE SLAB, OR CORNERS.
L/2 +
LAP LENGTH, TYP W/2
W /2
LA
P L
E N
G
TH
, T Y
P L/
L/
D /2
LA
P L
E N
G
TH
, T Y
P D
D/2 +
LAP LENGTH, TYP
L/2 + LUNGH.
ANCORAGGIO TIP.
2 Ø16 X 1200mm AD OGNI
FACCIA TIP. 4 POSIZIONI
CL SYMM ABOUT OPENING
SIMMETRICO RISPETTO
AL FORO
D/2 + LUNGH.
ANCORAGGIO TIP.
SIMMETRICO RISPETTO AL
FORO
W /2
L
U N
G H
A
N C
O R
A G
G
IO
T
IP
D /2
L
U N
G H
A
N C
O R
A G
G
IO
T
IP
NOTE:
1. PREDISPORRE ARMATURA AGGIUNTIVA DELLA STESSA DIMENSIONE DELL'ARMATURA
DISCONTINUA IN CORRISPONDENZA DELLE APERTURE. LA QUANTITA' DI ARMATURA IN
OGNI DIREZIONE DOVRA' ESSERE UGUALE O MAGGIORE AL NUMERO DELLE BARRE
DISCONTINUE. POSIZIONARE 1/2 DELLE BARRE DI ARMATURA AGGIUNTIVA A CIASCUN
LATO DEL FORO, POSIZIONARE ARMATURA AGGIUNTIVA A INTERASSE 75mm (TIPICA
NELLE DUE DIREZIONI E TUTTI GLI STRATI DI ARMATURA). ISTALLARE LA PRIMA BARRA
50mm DAL BORDO DELL'APERTURA.
2. ESTENDERE L'ARMATURA AGGIUNTIVA OLTRE IL BORDO DEL FORO COME SU INDICATO.
BARRE AGGIUNTIVE POSSONO TERMINARE ALLA FINE DEL MURO CON UN GANCIO
STANDARD LADDOVE LA LUNGHEZZA DEL MUTO NON PERMETTA ALLE BARRE DI
ESTENDERSI OLTRE COME SU MOSTRATO.
3. ARMATURA TIPICA DELLA PARETE O SOLAIO NON MOSTRATA PER CHIAREZZA.
TERMINARE ARMATURA TIPICA 50mm DAL BORDO DEL FORO.
4. PER FORI DI 300mm O MENO NEI SOLAI E NELLE PARETI NON SONO RICHIESTE
BARRE AGGIUNTIVE SALVO DIVERSA INDICAZIONE. L'ARMATURA TIPICA SARA'
RIDISTRIBUITA (NON TAGLIATA) PER PERMETTERE LA REALIZZAZIONE DEL FORO.
5. SALVO DIVERSAMENTE INDICATO SULLE TAVOLE, PREDISPORRE ARMATURA
AGGIUNTIVA INTORNO AI FORI COME MOSTRATO SU.
6. DISPORRE BARRE DI ANCORAGGIO AGGIUNTIVE COME DA NOTA 1 SOPRA TUTTI I FORI
VICINO AL SOLAIO DI PIANO, BASE O ANGOLI.
STD HOOK
GANCIO STANDARD
STD HOOK
GANCIO STANDARD
NOTES:
1. ALL HOOKS SHALL BE STD 90 DEGREE HOOKS.
2. OPTIONAL LAP LOCATION. APPLIES TO BOTH DOUBLE AND SINGLE LAYER
CONDITIONS TYP.
NOTE:
1. TUTTI I GANCI SARANNO GANCI STANDARD A 90 GRADI.
2. POSIZIONE OPZIONALE DELLA SOVRAPPOSIZIONE. APPLICABILE A CONDIZIONI
CON ARMATURA IN STRATO SINGOLO E DOPPIO, TIP.
HOOK
ALTERNATE DIRECTION OF HOOKS
SEE DRAWINGS FOR REINF SIZE
AND LOCATION, TYP
SEE NOTE 2
VEDI NOTA 2
LA
P
S P
LI
C
E m m
OPTIONAL
LAP
1220mm
MIN, TYP
LAP SPLICE + 150mm
SOVRAPPOSIZIONE +150mm
S O
V R
A P
P O
S
IZ
IO
N
E
+1 m m
ALTERNARE DIREZIONE DEI GANCI
GANCIO
1220mm
MIN TIP.
SOVRAPP.
OPZIONALE
VEDI DISEGNI PER DIMENSIONI E
POSIZIONE DELL'ARMATURA, TIP.
OPTIONAL
CONST JOINT
CONCRETE FOOTING
FONDAZIONE IN CLS
GIUNTO DI COSTR.
OPZIONALE
OPTIONAL
CONST JOINT
CONCRETE FOOTING
FONDAZIONE IN CLS
GIUNTO DI COSTR.
OPZIONALE
INTERNAL CORNER
ANGOLO INTERNO
DISCONTINUOUS JOINT INTERSECTION
INTERSEZIONE GIUNTO DISCONTINUO
2- Ø12 x 600mm LONG 50mm BELOW SURFACE
2- Ø12 x 600mm LONG 50mm BELOW SURFACE
SLAB EDGE
BORDO SOLETTA
CJ
2- Ø12 x 600mm DI LUNG.
50mm AL DI SOTTO
DELLA SUPERFICIE
2- Ø12 x 600mm DI LUNG.
50mm AL DI SOTTO
DELLA SUPERFICIE
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E
INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR.
NO.
SHEET
NAVFAC DRAWING
NO.
DES DRW CHK
OF
EPROJECT
NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
Y
E N
G
IN
E E
R
IN
G S
Y S
T E
M C
O M
M A
N D
NAVFAC METRIC DRAWFORM REVISION: 07 AUGUST 2018
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
Y E
N G
IN
E
E R
IN
G
S Y
S T
E M
C O
M M
A N
D
A T
L A
N T
IC
N
O R
F O
L K
V
IR
G
IN
IA
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
A V
IA
N
O A
IR
B
A S
E A
V
IA
N O
, I T
A
LY
A R
E A
A
E N
T R
Y C
O N
T R
O L
P O
IN
T
LET/JSL
DPS
1917 SOUTH 67TH STREET
OMAHA, NE 68106
/6
/2
:2
:5
P M
B
IM
/1
N
A V
F A
C A
D e s ig n A v ia n o
It a ly
/1
-S -G e n e ra l_ v
.r v t
S-501
TY
P
IC
A
L S
T R
U C
TU
R
A L
C O
N C
R E
T E
D E
TA
IL
S
DE
TT
AG
LI
S
TR
UT
TU
RA
LI
T
IP
IC
I N
EL
CA
LC
ES
TR
UZ
ZO
SKM
14090082
ARA JMH
22 MARCH, 2021
APPROVED BY SCOTT KIBLER
VIA E-MAIL
1631931
N62470-21-C-0003
A T
L A
N T
IC
D
E S
IG
N
A N
D C
O N
S T
R U
C T
IO
N
RICHARD STEPHENS, PE
JTW
NOT TO SCALE
NON IN SCALA
C1
CONCRETE REINFORCING LAP SPLICE SCHEDULE
NOT TO SCALE
NON IN SCALA
B3
EXTRA REINFORCING AROUND OPENINGS
NOT TO SCALE
NON IN SCALA
A1
TYPICAL CONCRETE WALL
CORNER & INTERSECTION REINF
NOT TO SCALE
NON IN SCALA
B2
TYPICAL FOOTING
REINFORCING @ CORNER
NOT TO SCALE
NON IN SCALA
A2
TYPICAL FOOTING
REINFORCING @ INTERSECTION
NOT TO SCALE
NON IN SCALA
A3
TYPICAL SLAB ON GRADE REINFORCING DETAILS
TABELLA SOVRAPPOSIZIONI DELL'ARMATURA NEL CALCESTRUZZO NON IN SCALA
ARMATURA TIPICA
D'ANGOLO DI FONDAZIONE
ARMATURA AGGIUNTIVA INTORNO ALLE APERTURE
ARMATURA TIPICA D'ANGOLO E
INTERSEZIONE DI PARETI IN CLS
ARMATURA TIPICA D'INTERSEZIONE
DI FONDAZIONE
DETTAGLI D'ARMATURA TIPICA NELLA SOLETTA A TERRA
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P
13mm WIDE GROOVE W/ BACKER ROD
AND SEALANT AT EXPOSED FLOORS
SLAB ON GRADE
13mm EXP JT MATERIAL
MATERIAL GIUNTO
DILATAZ. 13mm
FACE OF WALL
SUPERFICIE PARETE
AT COLUMN
IN CORRISPONDENZA DEI PILASTRI
13mm WIDE x 13mm DEEP GROOVE
W/ SEALANT AT EXPOSED FLOORS
COLUMN
PILASTRO
"T
C
LR
GIUNTO LARGO 13mm CON CORDONE
DI SIGILLATURA E SIGILLANTE A
PAVIMENTI ESPOSTI
SOLETTA A TERRA GIUNTO LARGO 13mm CON CORDONE
DI SIGILLATURA E SIGILLANTE A
PAVIMENTI ESPOSTI
DIS
T.75 mm
85 MIN
AS REQ'D SEE NOTE 2 BELOW
COME RICHIESTO VEDI NOTA 2
SOTTO
Ø12/300 EW
Ø12/300 DUE DIREZ.
NOTES:
1. PROVIDE ABOVE PAD UNDER ALL ELECTRICAL AND MECHANICAL EQUIPMENT SUPPORTED ON
STRUCTURAL SLABS. ALSO PROVIDE FOR EQUIPMENT WEIGHING LESS THAN 2270kg
WHICH ARE SUPPORTED ON GRADE OR WHERE SPECIFICALLY NOTED ON PLANS.
2. PAD THICKNESS SHALL BE THE LARGER OF SLAB THICKNESS PLUS 90mm PROVIDE AN ADDITIONAL LAYER OF 12@300mm EACH WAY WITH 40mm CLEAR TOP AND BOTTOM FOR EACH 200mm ADDITIONAL PAD THICKNESS EXCEEDING THE 85mm MINIMUM THICKNESS.
ALTERNATIVELY, THICKEN SLAB ON GRADE BELOW EQUIPMENT PAD AS REQD TO MAINTAIN
MIN 75mm COVER ON ANCHOR BOLTS.
PAD NOTES:
1. ABOVE PAD DETAILS APPLY FOR SUPPORT OF ALL EQUIPMENT UNLESS INDICATED OTHERWISE
ON THE DRAWINGS.
2. 150mm MINIMUM PAD EDGE DIMENSION TO EQUIPMENT AB APPLIES FOR ALL EQUIPMENT SUPPORT PADS.
Ø12 CLOSED TIE ADDL CONT @ PERIMETER
STAFFE CHIUSE Ø12 AGGIUNTIVE CONTINUE
AL PERIMETRO
CONCRETE SURFACE SHALL BE CLEAN, FREE OF LAITANCE,
ROUGHENED TO A 6mm AMPLITUDE, & COATED W/ BONDING AGENT
LA SUPERFICIE DI CALCESTRUZZO DOVRA' ESSERE PULITA DA
POLVERI E RESA SCABRA CON LARGHEZZA 6mm E TRATTATA CON
UN AGENTE ADESIVO
20mm CHAMFER TYP SMUSSATURA TIP. 20mm
SEE PLAN FOR SLAB THICKNESS & REINFORCING
VEDI PIANTA PER SPESSORE SOLETTE E ARMATURA
EQUIP BASE
BASE
MACCHINA
Ø12/300 TYP PLACE VERT LEG IN 20mm DIA
DRILLED HOLE FILLED W/NON-SHRINK GROUT
OR Ø12/300 HOOKED EE CAST INTO SLAB
200mm LEG TYP PIEGATURA TIP. 200mm
EQUIP AB
ANCOR.
MACCHINA
100 MIN
150 MIN
C
LR
Ø12/300 TIP. POSIZIONARE PIEGA VERTICALE IN FORO
20mm DIAM. RIEMPITO CON MALTA ANTIRITIRO O Ø12/300
PIEGATO ALL'ESTREMITA' E GETTATO NELLA SOLETTA
NOTE:
1. PREDISPORRE TUTTE LE MACCHINE DI IMPIANTI ELETTRICI E MECCANICI MANTENUTI DA SOLAI STRUTTURALI SU BASAMENTI. FORNIRE ANCHE PER IMPIANTI CON PESO MINORE DI 2270 kg CHE SONO POGGIATI SUL TERRENO O
LADDOVE SPECIFICAMENTE ANNOTATO SULLE TAVOLE.
2. LO SPESSORE DEI BASAMENTI SARA' IL MAGGIORE DELLO SPESSORE DEL SOLAIO PIU' 90mm. FORNIRE UNO STRATO DI ARMATURA AGGIUNTIVA F12/300mmNELLE DUE DIREZIONI CON 40mm DI DISTANZA LIBERA SUPERIORE E INFERIORE PER OGNI 200mm DI SPESSORE DI BASAMENTO AGGIUNTIVO IN ECCESSO DI 85mm DI SPESSORE MINIMO. IN ALTERNATIVA, INSPESSIRE LA SOLETTA A TERRA AL DI SOTTO DELLA MACCHINA COME NECESSARIO PER MANTENERE 75mm DI COPRIFERRO MIN SULLE BARRE DI ANCORAGGIO.
NOTE BASAMENTI:
1. I DETTAGLI SUI BASAMENTI SONO APPLICABILI PER SUPPORTI DI TUTTE LE MACCHINE SALVO DIVERSA
INDICAZIONE SUI DISEGNI.
2. LA DIMENSIONE MINIMA DI 150mm DAL BORDO DEL BASAMENTO ALLA MACCHINA E' APPLICABILE A TUTTI I
SUPPORTI PER LE MACCHINE.
25mm MIN NON-SHRINK GROUT MALTA ANTIRITIRO 25mm MIN
AS INDICATED ON DWGS OR AS REQUIRED
BY EQUIPMENT FURNISHED 200mm MIN (UNO)
NOTES:
1. SEE PAD NOTES AT DETAIL C3 THIS SHEET.
2. PROVIDE PAD UNDER ELECTRICAL AND MECHANICAL EQUIPMENT
WEIGHING MORE THAN 2300kg, AND SUPPORTED ON GRADE
UNLESS NOTED OTHERWISE ON PLANS.
3. FOR EQUIPMENT FOUNDATIONS OUTSIDE ON GRADE SEE DETAIL C6
THIS SHEET.
EQUIPMENT BASE
BASE MACCHINA
Ø16/300 T&B
Ø16/300 SUP. E INF.
DOUBLE NUT
DOPPIO DADO
1:1 SLOPE TYP
TIP. PENDENZA 1:1
13mm EXP JT ALL AROUND GIUNTO DILATAZIONE 13mm INTORNO
ANCHOR BOLT
TIRAFONDO
SEE PLANS FOR SLAB THICKNESS AND REINFORCING
VEDI PIANTE PER SPESSORE SOLETTA E ARMATURA
Ø12 CLOSED TIES @ 150mm STAFFE Ø12 /150mm CHIUSE
50 CLR
100 MIN ALL AROUND
150 MIN
C
LR
100 MIN INTORNO
COME INDICATO SUI DISEGNO O COME
RICHIESTO DALLA MACCHINA FORNITA
200mm MIN (SALVO DIV. INDIC.)
NOTE:
1. VEDI NOTE BASAMENTI SUL DETTAGLIO C3 DI QUESTA TAVOLA.
2. FORNIRE BASAMENTI AL DI SOTTO DI IMPIANTI MECCANICI ED
ELETTRICI CON PESO MAGGIORE DI 2300kg E POGGIATI A TERRA S
ALVO DIVERSAMENTE INDICATO SUI DISEGNI.
3. PER FONDAZIONI DI MACCHINE NON POGGIATE A TERRA
VEDI DETTAGLIO C6 SU QUESTA TAVOLA.
NOTES:
1.
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .