Att. H - 1631931dwg3of4.pdf

PDF 10 MB Posted

Attached to
Construction of Entry Control Point at Aviano Air Base
Solicitation number
N6247021R0003
Issued by

About this file

This document provides details on a federal solicitation opportunity. The solicitation number is N6247021R0003 and concerns the construction of an Entry Control Point at Aviano Air Base in Italy. The Naval Facilities Engineering Command within the Department of the Navy is the contracting agency. Responses to the solicitation are due based on the dates and instructions provided in solicitation number N6247021R0003 and its accompanying attachments, which include drawing number 1631931dwg3of4. The opportunity is for the construction services required to build the Entry Control Point at the specified military base in Italy.

View the file

Other files

File Type Posted
N6247021R0003 Amend 0009.pdf PDF
N6247021R0003 Amend 0008.pdf PDF
N6247021R0003 Amend 0007.pdf PDF
Attachment N - Anti-Mafia Self-Certification Form for Contracts between 150K and 5.3M.pdf PDF
Attachment O - Anti-Mafia Self-Certification Form for Contracts greater than 5.3M.pdf PDF
N6247021R0003 Amend 0006.pdf PDF
Attachment M - 01 33 00 Addendum 04-01-2022.pdf PDF
N6247021R0003 Amend 0005.pdf PDF
N6247021R0003 Amend 0004.pdf PDF
Attachment L - P23005 Site Visit Attendance List.pdf PDF
N6247021R0003 Amend 0003.pdf PDF
Attachment K - Engineering Calculations_P23005.pdf PDF
N6247021R0003 Amend 0002.pdf PDF
N6247021R0003 Amend 0001.pdf PDF
Att. G - 1631931_SupplementalAttachment_SitePhotographs_2of3.pdf PDF
Att. I - MASW_srt5.pdf PDF
Att. I - Utilities survey.pdf PDF
Att. H - 1631931dwg2of4.pdf PDF
Att. G - 1631931_SupplementalAttachment_SitePhotographs_1of3.pdf PDF
Attachment E - SEC-NAV_5512_1_11787 Form.pdf PDF
Att. H - 1631931dwg4of4.pdf PDF
Att. I - Appendix B - Photographic annex.pdf PDF
N6247021R0003 Solicitation.pdf PDF
Att. G - 1631931spc1of1.pdf PDF
Attachment C - Construction Experience Project Data Sheet.pdf PDF
Attachment J- Environmental and Hazardous Material Report.pdf PDF
Att. G - P23005_Final_Relazione Copertura Search Office_Roof Report.pdf PDF
Att. G - P23005_Final_Relazione Copertura Canopy_Roof Report.pdf PDF
Attachment F - LRA Commercial Vehicle Inspection Procedures.pdf PDF
Att. I - MASW_srt6.pdf PDF
Att. I - Appendix C - Geotechnical parameters charts.pdf PDF
Att. I - Geophysics Report.pdf PDF
Att. I - MASW_srt4.pdf PDF
Att. G - P23005_Final_Relazione Copertura Gatehouse_Roof Report.pdf PDF
Att. I - MASW_srt2.pdf PDF
Att. I - Appendix D - Geotechnical lab reports.pdf PDF
Att. G - P23005_Final_PSC_SafetyPlan.pdf PDF
Attachment B- Schedule B Price Proposal Form.pdf PDF
Att. H - 1631931dwg1of4.pdf PDF
Att. I - MASW_srt3.pdf PDF
Att. G - 1631931_SupplementalAttachment_SitePhotographs_3of3.pdf PDF
Att. I - MASW_srt9.pdf PDF
Attachment A - Pre-Proposal Inquiry Form.xls XLS spreadsheet
Att. I - MASW_srt8.pdf PDF
Att. I - Appendix A - Boring logs.pdf PDF
Att. I - SRT Graphs.pdf PDF
Att. I - MASW_srt1.pdf PDF
Attachment D - Past Performance Questionnaire (PPQ).pdf PDF
Att. I - MASW_srt7.pdf PDF
Show all 49

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E

INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR.

NO.

SHEET

NAVFAC DRAWING

NO.

DES DRW CHK

OF

EPROJECT

NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

Y

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

NAVFAC METRIC DRAWFORM REVISION: 07 AUGUST 2018

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

Y E

N G

IN

E

E R

IN

G

S Y

S T

E M

C O

M M

A N

D

A T

L A

N T

IC

N

O R

F O

L K

V

IR

G

IN

IA

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

A V

IA

N

O A

IR

B

A S

E A

V

IA

N O

, I T

A

LY

A R

E A

A

E N

T R

Y C

O N

T R

O L

P O

IN

T

LET/JSL

DPS

1917 SOUTH 67TH STREET

OMAHA, NE 68106

/6

/2

:2

:5

P M

B

IM

/1

N

A V

F A

C A

D e s ig n A v ia n o

It a ly

/1

-S -G e n e ra l_ v

.r v t

S-001

G E

N E

R A

L S

T R

U C

TU

R

A L

N O

TE

S

NO

TE

G

EN

ER

AL

I S

TR

UT

TU

RA

LI

SKM

14090079

ARA JMH

22 MARCH, 2021

APPROVED BY SCOTT KIBLER

VIA E-MAIL

1631931

N62470-21-C-0003

A T

L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

RICHARD STEPHENS, PE

JTW

GENERAL NOTES

APPLICABLE CODES AND STANDARDS

1. INTERNATIONAL BUILDING CODE 2018.

2. BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE ACI-318-14.

3. MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES ASCE7-16.

4. AMERICAN INSTITUTE OF STEEL CONSTRUCTION AISC STEEL CONSTRUCTION

MANUAL, 14TH ED.

5. STEEL DECK INSTITUTE SPECIFICATIONS AND LOAD TABLES.

6. AISI SPECIFICATION FOR DESIGN OF COLD FORMED STEEL STRUCTURAL

MEMBERS.

7. AMERICAN WELDING SOCIETY (AWS) D1.1, D1.3, D1.4.

8. ASTM MATERIAL STANDARDS AS NOTED.

9. UFC 1-200-01 GENERAL BUILDING REQUIREMENTS

(OCTOBER 2019)

10.UFC 3-301-01 STRUCTURAL ENGINEERING

(OCTOBER 2019)

11.UFC 4-010-01 DOD MINIMUM ANTITERRORISM STANDARDS

FOR BUILDINGS

(DECEMBER 2018, W/ CHANGE 1 AUG 2020)

12.UFC 4-022-01 ENTRY CONTROL FACILITIES ACCESS CONTROL POINTS

(JULY 2017)

13.LAW NO. 1086 DATED 11/5/71 REGARDING REINFORCED CONCRETE AND PRE-

STRESSED REINFORCED CONCRETE STRUCTURES AND STEEL STRUCTURES.

14.SEISMIC DESIGN FOR BUILDINGS - ACT NO 64 DATED 2/2/74

15.DM 17 -01-2018 NEW TECHNICAL NORMS FOR BUILDING CONSTRUCTIONS

16.CIRC. 21 JANUARY 2019 N. 7/C.S.LL.PP.

17.EUROCODE

EXISTING CONDITIONS

1. NOTIFY CONTRACTING OFFICER IMMEDIATELY IF EXISTING CONDITIONS DO

NOT MATCH, OR SEEM IN CONFLICT WITH INFORMATION SHOWN ON THE

DRAWINGS.

GENERAL NOTES

1. THE DRAWINGS REPRESENT THE FINISHED STRUCTURE, NOT THE METHOD

OF CONSTRUCTION. SAFETY AND STRUCTURAL STABILITY DURING

CONSTRUCTION ARE THE SOLE REPSONSIBILITY OF THE CONTRACTOR. THE

CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE

STRUCTURE DURING CONSTRUCTION, INCLUDING BUT NOT LIMITED TO,

BRACING, SHORING, FOR CONSTRUCTION LOADS AND EQUIPMENT, ETC.

2. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH THE

ARCHITECTURAL, MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR

LOCATION AND SIZE OF OPENINGS, BLOCK OUTS, FLOOR DEPRESSIONS,

CURBS, DIMENSIONS, ETC. NOT INDICATED ON THE STRUCTURAL DRAWINGS.

THE LOCATION AND SIZE OF MECHANICAL AND ELECTRICAL OPENINGS IN

SLABS, WALLS AND DECKS SHALL BE COORDINATED BY THE CONTRACTOR.

PROVIDE ALL ADDITIONAL FRAMING OR REINFORCING TO ACCOMMODATE

OPENINGS AS REQUIRED BY THE APPLICABLE STANDARD DETAILS, SECTIONS

AND NOTES AS SHOWN ON THE STRUCTURAL DRAWINGS.

3. THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND ELEVATIONS

OF EXISTING CONSTRUCTION AS REQUIRED TO COORDINATE NEW

CONSTRUCTION. SUBMIT REQUIRED CHANGES FOR APPROVAL.

4. CONTRACTOR IS TO ESTABLISH AND VERIFY EMBEDS AND INSERTS ITEMS TO

BE INSTALLED BY OTHER TRADES PRIOR TO SUBMITTAL OF SHOP DRAWINGS

AND CONSTRUCTION.

5. CONSTRUCTION MATERIAL AND EQUIPMENT PLACED ON FRAMED

CONSTRUCTION SHALL BE SUCH THAT THE LOAD DOES NOT EXCEED THE

DESIGN LIVE LOAD OF THE CONSTRUCTIONS. PROVIDE SHORING OF

CONSTRUCTIONS WHERE NECESSARY FOR THE LOADS.

6. DETAILS AND SECTIONS THAT ARE NOTED AS “TYP” ON DETAIL TITLES ARE TO

BE APPLIED TO THE PROJECT CONSTRUCTION AS GENERAL CONSTRUCTION

METHODS UNLESS NOTED OTHERWISE. THESE DETAILS ARE NOT CUT AT ALL

LOCATIONS THEY OCCUR AND MAY BE NOT CUT AT ALL.

7. CONTRACTOR TO SUBMIT FOR REVIEW ALL EQUIPMENT SIZES, OPERATING

WEIGHTS, VIBRATIONAL FORCES, SUPPORTED LOCATIONS, ALONG WITH ANY

FLOOR OPENINGS, NOTCHES, AND RECESSED REQUIRED BY SUCH

EQUIPMENT. CONCRETE SUPPORT PADS AND / OR FRAMING REQUIRED TO

SUPPORT SAID EQUIPMENT SHALL NOT BE FABRICATED AND PLACED UNTIL

THE CONCRETE SUPPORT PADS AND / OR FRAMING IS APPROVED TO

SUPPORT THE EQUIPMENT.

BUILDING OCCUPANCY CATEGORY – RISK FACTOR

1. RISK FACTOR: II

SNOW LOAD

1. GATEHOUSE AND SEARCH OFFICE

a. SNOW LOADS IN ACCORDANCE WITH THE BUILDING CODE LISTED ABOVE

b. EXPOSURE FACTOR, CE: 1.0

c. SNOW LOAD IMPORTANCE FACTOR, IS: 1.0

d. THERMAL FACTOR, CT: 1.0

e. GROUND SNOW LOAD, PG: 1.68 kPa

f. RAIN-ON-SNOW: 0 kPa

g. FLAT ROOF SNOW LOAD, PF: 1.2 kPa

2. CANOPY AND METAL BUILDINGS

a. SNOW LOADS IN ACCORDANCE WITH THE BUILDING CODE LISTED ABOVE.

b. EXPOSURE FACTOR, CE: 1.0

c. SNOW LOAD IMPORTANCE FACTOR, IS: 1.0

d. THERMAL FACTOR, CT: 1.2

e. GROUND SNOW LOAD, PG: 1.68 kPa

f. RAIN-ON-SNOW: 0 kPa

g. FLAT ROOF SNOW LOAD, PF: 1.40kPa

LIVE LOAD ON FLOOR

1. OFFICE: 3.0 kPa

2. MECHANICAL: 6.0 kPa

3. ELECTRICAL: 6.0 kPa

4. PUBLIC ROOMS, LOBBIES, FIRST FLOOR CORRIDORS: 4.8 kPa

5. STORAGE: 6.0 kPa

6. GUARD HOUSE 3.6 kPa

LIVE LOAD ON ROOF 1.00 kPa & SOLAR PANEL

LOADS

WIND LOAD

1. WIND LOADS IN ACCORDANCE WITH THE BUILDING CODE LISTED ABOVE.

2. BASIC WIND SPEED- (3 SECOND GUST)- ULTIMATE: 148km/h

3. EXPOSURE CATEGORY: C

4. INTERNAL PRESSURE COEFFICIENT: 0.18

WIND LOAD (ITALIAN CODE)

1. REFERENCE WIND SPEED: vb=25 m/s

2. EXPOSURE CATEGORY: III

3. REFERENCE KINETIC PRESSURE: 0.39 kPa

4. DYNAMIC COEFFICIENT: cd=1.0

SEISMIC LOAD

1. SEISMIC LOADS IN ACCORDANCE WITH THE BUILDING CODE LISTED ABOVE

2. IMPORTANCE FACTOR, IE: 1.0

3. SPECTRAL RESPONSE ACCELERATIONS, SS: 1.25G

4. SPECTRAL RESPONSE ACCELERATIONS, S1: 0.5G

5. SEARCH OFFICE AND GATEHOUSE:

a. SITE CLASS: C

b. SPECTRAL RESPONSE COEFFICIENT, SDS: 0.833

c. SPECTRAL RESPONSE COEFFICIENT, SD1: 0.5

d. SEISMIC DESIGN CATEGORY: D

e. SEISMIC RESPONSE COEFFICIENT, CS: 0.167

f. SEISMIC FORCE RESISTING SYSTEM: SPECIAL REINFORCED

CONCRETE SHEAR

WALLS

6. ID CHECK CANOPY:

a. SITE CLASS: C

b. SPECTRAL RESPONSE COEFFICIENT, SDS: 0.833

c. SPECTRAL RESPONSE COEFFICIENT, SD1: 0.5

d. SEISMIC DESIGN CATEGORY: D

e. SEISMIC RESPONSE COEFFICIENT, CS: 0.185

f. SEISMIC FORCE RESISTING SYSTEM: ORDINARY STEEL

MOMENT FRAMES

7. RESPONSE MODIFICATION FACTOR, R:

a. GATEHOUSE AND SEARCH OFFICE 5

b. CANOPY 3.5

8. ANALYSIS PROCEDURE: EQUIVALENT LATERAL

FORCE

SEISMIC LOADS (ITALIAN CODE)

1. LATITUDE: 46.07

2. LONGITUDE: 12.58

3. SITE CLASS: B

4. SERVICEABILITY LIFE: Vn=50 years

5. OCCUPANCY CLASS: II

6. OCCUPANCY FACTOR: Cu=1.0

7. REFERENCE LIFE: 50 years

8. SOIL ACCELERATION PARAMETERS SLV: ag/g=0.2425 F0=2.42 Tc=0.33

9. RETURN PERIOD SLV: 475 years

NOTE GENERALI

NORMATIVA E STANDARD APPLICABILI

1. NORME INTERNAZIONALI DELLE COSTRUZIONI 2018

2. REQUISITI DI PROGETTO PER CALCESTRUZZO ARMATO ACI-318-14

3. CARICHI MINIMI DI PROGETTO PER EDIFICI ED ALTRE STRUTTURE ASCE7-16.

4. ISTITUTO AMERICANO DI COSTRUZIONI IN ACCIAIO AISC MANUALE DI

COSTRUZIONI IN ACCIAIO, 14a EDIZIONE

5. SPECIFICHE E TABELLE DI CARICO ISTITUTO DI LAMIERE DI ACCIAIO

6. AISI SPECIFICHE PER IL PROGETTO DI ELEMENTI STRUTTURALI DI ACCIAIO

PROFILATI A FREDDO.

7. SOCIETA' AMERICANA SALDATURE (AWS) D1.1, D1.3, D1.4.

8. MATERIALI STANDARD ASTM COME INDICATO.

9. UFC 1-200-01 REQUISITI GENERALI DELLE STRUTTURE

(OTTOBRE 2019)

10.UFC 3-301-01 INGEGNERIA STRUTTURALE

(OTTOBRE 2019)

11.UFC 4-010-01 STANDARD MINIMI ANTITERRORISMO PER EDIFICI

(DICEMBRE 2018 CON CAMBIO 1 AGOSTO 2020)

12.UFC 4-022-01 STRUTTURE DI CONTROLLO DI INGRESSO PUNTI DI

CONTROLLO ACCESSO (LUGLIO 2017)

13.LEGGE NO. 1086 5/11/1971 NORME TECNICHE PER IL CALCOLO L'ESECUZIONE

E IL COLLAUDO DI STRUTTURE IN CALCESTRUZZO ARMATO NORMALE E

PRECOMPRESSO E DI STRUTTURE IN ACCIAIO.

14.NORME TECNICHE PER LE COSTRUZIONI IN ZONA SISMICA- LEGGE 64 -

2/2/1974)

15.DM 17-01-2018 AGGIORNAMENTO ALLE NORME TECNICHE PER LE

COSTRUZIONI.

16.CIRC. 21/2/2019 ISTRUZIONI PER L'APPLICAZIONE DELLE NUOVE NORME

TECNICHE PER LE COSTRUZIONI

17.EUROCODICI

CONDIZIONI ESISTENTI

1. NOTIFICARE L'UFFICIALE CONTRAENTE IMMEDIATAMENTE SE LE CONDIZIONI

NON CORRISPONDONO O APPAIONO IN CONFLITTO CON LE INFORMAZIONI

INDICATE NEI DISEGNI.

NOTE GENERALI

1. I DISEGNI RAPPRESENTANO LA STRUTTURA FINITA, NON IL METODO DI

COSTRUZIONE. LA SICUREZZA E LA STABILITA' DURANTE LA COSTRUZIONE

SARANNO RESPONSABILITA' UNICA DELL'APPALTATORE. L'APPALTATORE

DOVRA' PREDISPORRE TUTTE LE MISURE NECESSARIE A PROTEGGERE LA

STRUTTURA DURANTE LA COSTRUZIONE, INCLUSE MA NON LIMITATE A

CONTROVENTATURE, SUPPORTI PER CARICHI DA COSTRUZIONE, IMPIANTI,

ECC.

2. LE TAVOLE STRUTTURALI DOVRANNO ESSERE USATE INSIEME ALLE TAVOLE

ARCHITETTONICHE, MECCANICHE, ELETTRICHE E IDRAULICHE PER

POSIZIONE E DIMENSIONI DI APERTURE, CHIUSURE, DEPRESSIONI SOLETTE,

BORDI, DIMENSIONI ECC. NON INDICATE NELLE TAVOLE STRUTTURALI.

POSIZIONE E DIMENSIONI DI FORI MECCANICI ED ELETTRICI IN SOLAI, PARETI

E SOLETTE SARA' COORDINATA CON L'APPALTATORE. FORNIRE TUTTI I TELAI

E ARMATURE ADDIZIONALI PER REALIZZARE I FORI COME RICHIESTO DAI

DETTAGLI STANDARD APPLICABILI, SEZIONI E NOTE, INDICATI NELLE TAVOLE

STRUTTURALI.

3. L'APPALTATORE DOVRA' VERIFICARE IN CANTIERE TUTTE LE DIMENSIONI E

QUOTE DELLA COSTRUZIONE ESISTENTE COME RICHIESTO PER COORDINARE

LA NUOVA COSTRUZIONE. SOTTOMETTERE PER APPROVAZIONE I CAMBI

NECESSARI.

4. L'APPALTATORE DOVRA' STABILIRE E VERIFICARE GLI INSERTI E GLI INCASSI

PER GLI ELEMENTI DA ISTALLARE SECONDO LE ALTRE DISCIPLINE PRIMA

DELLA SOTTOMISSIONE DEGLI SHOP DRAWINGS E DELLA COSTRUZIONE.

5. I MATERIALI DI COSTRUZIONE E GLI IMPIANTI POSIZIONATI SU COSTRUZIONI

INTELAIATE SARANNO TALI DA NON ECCEDERE IL CARICO ACCIDENTALE DI

PROGETTO DELLE COSTRUZIONI. PREDISPORRE PUNTELLAMENTI DELLE

STRUTTURE LADDOVE NECESSARIO PER I CARICHI.

6. DETTAGLI E SEZIONI CHE SONO INDICATE CON "TYP" SUI TITOLI DEL

DETTAGLIO SARANNO DA APPLICARE ALLA COSTRUZIONE DEL PROGETTO

COME METODI GENERALI DI COSTRUZIONE SALVO DIVERSA INDICAZIONE.

TALI DETTAGLI NON SONO INDICATI A TUTTE LE POSIZIONI DOVE SI TROVANO

E POTREBBERO NON TROVARSI AFFATTO.

7. L'APPALTATORE DOVRA' SOTTOMETTERE PER REVISIONE TUTTE LE

DIMENSIONI, CARICHI AGENTI, FORZE DI VIBRAZIONE, POSIZIONI DEI

SUPPORTI DEGLI IMPIANTI, INSIEME A QUALSIASI FORO NEI SOLAI, INTAGLIO E

RIENTRANZA RICHIESTA DA TALE IMPIANTO. I BASAMENTI IN CLS DI

SUPPORTO E/O INTELAIATURE NECESSARIE PER IL SUPPORTO NON

DOVRANNO ESSERE FABBRICATE E POSIZIONATA FINO A CHE I BASAMENTI DI

CLS E/O INTELAIATURE SIANO STATE APPROVATE PER SOSTENERE GLI

IMPIANTI.

BUILDING OCCUPANCY CATEGORY – RISK FACTOR

1. FATTORE DI RISCHIO: II

CARICO DA NEVE

1. CORPO DI GUARDIA E UFFICIO CONTROLLI

a. CARICHI DA NEVE IN ACCORDO CON LE NORMATIVE DI COSTRUZIONE

SUINDICATE.

b. ATTORE DI ESPOSIZIONE CE 1.0

c. FATTORE DI IMPORTANZA CARICO DA NEVE, IS: 1.0

d. FATTORE TERMICO, CT: 1.0

e. CARICO DA NEVE AL SUOLO, PG 1.68 kPa

f. PIOGGIA SU NEVE: 0 kPa

g. CARICO DA NEVE SU COPERTURA, PF: 1.2 kPa

2. EDIFICI METALLICI E PENSILINE

a. CARICHI DA NEVE IN ACCORDO CON LE NORMATIVE DI COSTRUZIONE

SUINDICATE.

b. FATTORE DI ESPOSIZIONE CE 1.0

c. FATTORE DI IMPORTANZA CARICO DA NEVE, IS: 1.0

d. FATTORE TERMICO, CT: 1.2

e. CARICO DA NEVE AL SUOLO, PG 1.68 kPa

f. PIOGGIA SU NEVE: 0 kPa

g. CARICO DA NEVE SU COPERTURA, PF: 1.4 kPa

CARICHI ACCIDENTALI SU SOLAI

1. UFFICI 3.0 kPa

2. LOCALI MECCANICI 6.0 kPa

3. LOCALI ELETTRICI 6.0 kPa

4. LOCALI PUBBLICI, HALL, CORRIDOI PIANO TERRA 4.8 kPa

5. MAGAZZINI 6.0 kPa

6. CORPO DI GUARDIA 3.6 kPa

CARICHI ACCIDENTALI SU COPERTURA 1.0 kPa E CARICHI

PANNELLI SOLARI

CARICHI DA VENTO

1. CARICHI DA VENTO IN ACCORDO CON LE NORMATIVE SUINDICATE.

2. VELOCITA' VENTO DI BASE -(RAFFICA 3-SEC) ULTIMO: 148km/h

3. CATEGORIA DI ESPOSIZIONE: C

4. COEFFICIENTE DI PRESSIONE INTERNA: 0.18

CARICHI DA VENTO (NORME ITALIANE)

1. VELOCITA' VENTO DI RIFERIMENTO vb=25m/s

2. CATEGORIA DI ESPOSIZIONE III

3. PRESSIONE CINETICA DI RIFERIMENTO 0.39 kPa

4. COEFFICIENTE DINAMICO cd=1.0

CARICHI SISMICI

1. CARICHI SISMICI IN ACCORDO CON LE NORMATIVE SUINDICATE

2. FATTORE DI IMPORTANZA, IE: 1.0

3. ACCELERAZIONE SPETTRALE, SS: 1.25G

4 ACCELERAZIONE SPETTRALE, S1: 0.5G

5. UFFICIO CONTROLLI E CORPO DI GUARDIA

a. CATEGORIA TERRENO: C

b. COEFFICIENTE DI RISPOSTA SPETTRALE, SDS 0.833

c. COEFFICIENTE DI RISPOSTA SPETTRALE, SD1 0.5

d. CATEGORIA SISMICA DI PROGETTO D

e. COEFFICIENTE DI RISPOSTA SISMICO, CS 0.167

f. SISTEMA RESISTENTE FORZE SISMICHE PARETI SPECIALI A

TAGLIO IN CLS ARMATO

6. PENSILINA CONTROLLO PASS

a. CATEGORIA TERRENO: C

b. COEFFICIENTE DI RISPOSTA SPETTRALE, SDS 0.833

c. COEFFICIENTE DI RISPOSTA SPETTRALE, SD1 0.5

d. CATEGORIA SISMICA DI PROGETTO D

e. COEFFICIENTE DI RISPOSTA SISMICO, CS 0.185

f. SISTEMA RESISTENTE FORZE SISMICHE TELAIO ORDINARIO IN

ACCIAIO A MOMENTO

7. FATTORE DI RISPOSTA, R:

a. CORPO DI GUARDIA E UFFICIO CONTROLLI 5

b. PENSILINA 3.5

8 . PROCEDURA FORZA LATERALE

EQUIVALENTE

CARICHI SISMICI (NORMATIVA ITALIANA)

1. LATITUDINE: 46.07

2. LONGITUDINE: 12.58

3. CATEGORIA DI SUOLO B

4. VITA NOMINALE: Vn=50 anni

5. CLASSE D'USO: II

6. FATTORE D'USO: Cu=1.0

7. VITA DI RIFERIMENTO: 50 anni

8. COEFF. DI ACCELERAZIONE AL SUOLO IN SLV ag/g=0.2425 F0=2.42 Tc=0.33

9. PERIODO DI RITORNO IN SLV 475 anni

S Y

M D

E S

C R

IP

TI

O N

D A

TE

A

P P

R

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E

INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR.

NO.

SHEET

NAVFAC DRAWING

NO.

DES DRW CHK

OF

EPROJECT

NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

Y

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

NAVFAC METRIC DRAWFORM REVISION: 07 AUGUST 2018

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

Y E

N G

IN

E

E R

IN

G

S Y

S T

E M

C O

M M

A N

D

A T

L A

N T

IC

N

O R

F O

L K

V

IR

G

IN

IA

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

A V

IA

N

O A

IR

B

A S

E A

V

IA

N O

, I T

A

LY

A R

E A

A

E N

T R

Y C

O N

T R

O L

P O

IN

T

LET/JSL

DPS

1917 SOUTH 67TH STREET

OMAHA, NE 68106

/6

/2

:2

:5

P M

B

IM

/1

N

A V

F A

C A

D e s ig n A v ia n o

It a ly

/1

-S -G e n e ra l_ v

.r v t

S-002

G E

N E

R A

L S

T R

U C

TU

R

A L

N O

TE

S

NO

TE

G

EN

ER

AL

I S

TR

UT

TU

RA

LI

SKM

14090080

ARA JMH

22 MARCH, 2021

APPROVED BY SCOTT KIBLER

VIA E-MAIL

1631931

N62470-21-C-0003

A T

L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

RICHARD STEPHENS, PE

JTW

GENERAL NOTES

STEEL DECK:

1. THE DESIGN, FABRICATION, AND ERECTION OF METAL DECKING SHALL BE IN

ACCORDANCE WITH THE CURRENT EDITION OF THE SDI SPECIFICATIONS AND

THE SDI DIAPHRAGM MANUAL.

2. STEEL ROOF DECK IS 55mm DEEP X 0.8mm THICK WIDE RIB METAL DECK AS

SHOWN ON THE PLANS DESIGNED FOR THE LIVE LOAD GIVEN ABOVE AND 0.6

kPa DEAD LOAD. MINIMUM SECTION PROPERTIES ARE AS FOLLOWS:

Jy = 60.12 cm4/m, We,inf = 21.86 cm3/m, We,sup = 21.86 cm3/m, Fy = 345 MPa, MINIMUM.

3. STEEL ROOF DECK IS TO BE A STRUCTURAL DIAPHRAGM AND SHALL BE

CONNECTED TO THE STRUCTURE AS SHOWN ON DRAWINGS.

4. SUSPENDED CEILINGS, LIGHT FIXTURES, DUCTS, AND OTHER UTILITIES SHALL

NOT BE SUPPORTED FROM THE STEEL DECK.

STRUCTURAL STEEL

1. STRUCTURAL STEEL DESIGN PROPERTIES:

WIDE FLANGE AND TEE SHAPES –

UNI 5398, UNI 5397 CLASSES

S355 Fy= 355 MPa

ANGLES, CHANNELS AND PLATES –

UNI 5398, UNI 5397 CLASSES

S275 Fy= 275 MPa

STEEL PIPE – UNI 7811 CLASSES

S355 Fy= 355 MPa

COLD-FORMED HOLLOW STRUCTURAL SECTIONS –

UNI EN 10219 CLASSES

S235 Fy= 235 MPa S275 Fy= 275 MPa S355 Fy= 355 MPa

COLD-FORMED HOLLOW STRUCTURAL PIPE –

UNI EN 10219 CLASSES

S235 Fy= 235 MPa S275 Fy= 275 MPa S355 Fy= 355 MPa STAINLESS STEEL Fy= 230 MPa

BOLTS – EN 14399 CLASSES

6.8 Fy= 600 MPa

8.8 Fy= 800 MPa

10.9 Fy= 1000 MPa

ANCHOR RODS – CLASSES

S275 Fy= 275 MPa

LIGHT GAGE STEEL STUDS/JOIST – CLASSES

S235 Fy= 235 MPa S275 Fy= 275 MPa S355 Fy= 355 MPa

2. ALL WELDS AND WELDING PROCEDURES SHALL BE PERFORMED IN

ACCORDANCE WITH APPLICABLE PROVISIONS OF AISC AND AWS WELDING

PROCEDURES AND CODES OUTLINED IN THE SPECIFICATION. ALL WELDS

SHALL BE MADE WITH E-70XX ELECTRODES AND IN ACCORDANCE WITH AWS

FOR METAL ALLOY BEING WELDED UNLESS NOTED OTHERWISE.

3. WHEN FILLET WELDS SIZES ARE NOT INDICATED, PROVIDE MINIMUM WELD

SIZE IN ACCORDANCE WITH AISC SPECIFICATIONS, TABLE J2.4. OR 5mm, WHICHEVER IS GREATER.

4. ALL GROOVE WELDS INDICATED ON THE PLANS AND SECTIONS SHALL BE

COMPLETE JOINT PENETRATION WELDS (CJP) UNLESS SPECIFICALLY

INDICATED TO BE PARTIAL PENETRATION WELDS.

5. DIMENSIONS TO CENTERLINE OF COLUMNS AND BEAMS, TOP SURFACES OF

BEAMS AND TUBES AND BACKS OF CHANNELS AND ANGLES UNLESS NOTED

OTHERWISE.

6. ALL FIELD BOLTED CONNECTIONS SHALL BE MADE WITH M20 EN 14399

CLASSES 6.8, 8.8, 10.9 BOLTS, UNLESS NOTED OTHERWISE. ALL FIELD BOLTED

CONNECTIONS SHALL BE SNUG TIGHTENED UNLESS INDICATED AS

PRETENSIONED OR SLIP CRITICAL. PRETENSIONED AND SLIP CRITICAL

CONNECTIONS SHALL BE TIGHTENED USING DIRECT TENSION INDICATORS.

INSTALL HIGH STRENGTH BOLTS ACCORDING TO RCSC’S “SPECIFICATION FOR

STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS” FOR THE TYPE OF

JOINT SPECIFIED.

7. DOUBLE ANGLE MEMBERS SHALL HAVE INTERMITTENT FILLER PLATES AS

REQUIRED BY SECTION E6 OF THE AISC MANUAL OF STEEL CONSTRUCTION.

SOILS INVESTIGATION:

1. SOILS INVESTIGATION WAS MADE BY: GOLDER ASSOCIATES S.R.I.

2. PROJECT NO.: N62742-D-0004

3. DATED: JULY 2020

4. ALLOWABLE BEARING PRESSURE:

a. SEARCH OFFICE AND GATE HOUSE: 191 kN/m2

b. ID CHECK CANOPY: 191 kN/m2

5. SOIL EFFECTIVE UNIT WEIGHT: 17202 kN/m3

6. FRICTION ANGLE: 38°

CONCRETE NOTES

1. CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF

ACI 301 AND ACI 318.

2. REINFORCING STEEL SHALL BE B450C, GRADE 450. REINFORCING STEEL TO

BE WELDED SHALL BE B450C, GRADE 450 .

3. CONCRETE COVER REQUIREMENTS FOR REINFORCEMENT UNLESS NOTED

OTHERWISE ON THE DETAILS OR SECTIONS:

CONCRETE CAST AND PERMANENTLY EXPOSED TO EARTH: 75mm

CONCRETE EXPOSED TO EARTH OR WEATHER:

20mm BARS AND LARGER 50mm 12m BARS AND SMALLER 40mm

CONCRETE NOT EXPOSED TO EARTH OR WEATHER:

SLABS 40mm WALLS 50mm

4. REINFORCING BAR SPLICES SHALL BE IN ACCORDANCE WITH THE

REQUIREMENTS OF ACI 318 AND THE REINFORCING SPLICE LENGTHS

SCHEDULE ON THE DRAWINGS.

5. CAST-IN-PLACE CONCRETE TO BE CLASS C35/45:

LOCATION 28-DAY F’C AIR MAX W/C MAX SLUMP

FOOTINGS/

FOUNDATION WALLS 35 MPa 6%+/-1% 0.45 100mm SLABS 35 MPa - 0.40 100mm EXTERIOR CONCRETE 35 MPa 6%+/-1% 0.45 100mm

6. ALL REINFORCEMENT FOR CAST-IN-PLACE CONCRETE SHALL BE

ACCURATELY PLACED, SUPPORTED, TIED AND SECURED INTO PLACE PRIOR

TO PLACING CONCRETE. ALL REBAR DOWELS SHALL BE TIED IN PLACE PRIOR

TO CONCRETE PLACEMENT. REBAR DOWELS SHALL NOT BE EMBEDDED

AFTER CONCRETE PLACEMENT UNLESS INDICATED ON THE DRAWINGS.

7. REFER TO OTHER DISCIPLINE DRAWINGS PRIOR TO CONSTRUCTION FOR

EMBEDDED ITEMS AND PENETRATIONS NOT SHOWN ON THE STRUCTURAL

DRAWINGS AS REQUIRED TO ACCOMMODATE ALL WORK SHOWN OR

SPECIFIED IN THE CONTRACT DOCUMENTS AND OTHERWISE REQUIRED FOR

THE FURNISHING OF A FUNCTIONALLY COMPLETE PROJECT. REINFORCE

AROUND OPENINGS PER STANDARD STRUCTURAL DETAILS UNLESS

OTHERWISE SHOWN.

8. PROVIDE 20mm CHAMFERS AT ALL EXPOSED EDGES. NOT ALL CHAMFERS

MAY BE SHOWN.

9. ANCHOR BOLTS NOT SPECIFIED BY THE CONTRACT DRAWINGS SHALL BE

DESIGNED AND CERTIFIED BY A REGISTERED PROFESSIONAL ENGINEER,

RETAINED BY THE CONTRACTOR IN ACCORDANCE WITH THE APPLICABLE

PROJECT AND CODE REQUIREMENTS. SUBMIT AS A SHOP DRAWING FOR

REVIEW AND APPROVAL BY THE CONTRACTING OFFICER. COORDINATE

LOCATION, SIZE AND EMBEDMENT PRIOR TO CASTING CONCRETE.

10.ALL CAST-IN-PLACE AND POST-INSTALLED ANCHORS INDICATED IN THE

STRUCTURAL DOCUMENTS SHALL COMPLY WITH APPENDIX D OF ACI 318 AND

CHAPTER 19 OF THE IBC. ALL EXPANSION AND ADHESIVE ANCHORS SHALL

HAVE AN ICC REPORT SHOWING EQUIVALENT LOAD CAPACITY. SUBMIT AND

INSTALL PER THE ICC EVALUATION REPORT.

11.PRIOR TO INSTALLING POST INSTALLED ANCHORS INTO CONCRETE, THE

CONTRACTOR SHALL LOCATE REINFORCING. DO NOT DAMAGE CONCRETE

REINFORCING. ABSOLUTELY NO WELDING OF REINFORCING BARS OR

TORCHING TO BEND REINFORCING BARS SHALL BE ALLOWED WITHOUT

SPECIFIC APPROVAL FROM THE CONTRACTING OFFICER.

NOTE GENERALI

INDAGINI GEOGNOSTICHE:

1. LE INDAGINI GEOGNOSTICHE EFFETTUATE DA: GOLDER ASSOCIATES SRL

2. PROGETTO NO. N62742-D-0004

3. DATATO: LUGLIO 2020

4. CAPACITA' PORTANTE:

a. UFFICIO CONTROLLI E CORPO DI GUARDIA: 191 kN/m2

b. PENSILINA CONTROLLO PASS: 191 kN/m2

5. PESO SPECIFICO EFFICACE TERRENO 17202 kN/m3

6. ANGOLO D'ATTRITO 38°

NOTE DEL CALCESTRUZZO

1. I LAVORI IN CALCESTRUZZO SARANNO IN ACCORDO AI REQUISITI DI ACI 301 E

ACI 318.

2. LE ARMATURE DI ACCIAIO SARANNO B450C. ACCIAIO D'ARMATURA DA

SALDARE SARA' B450C.

3. I REQUISITI DI COPRIFERRO PER ARMATURA SALVO DIVERSA INDICAZIONE

SUI DETTAGLI O SEZIONI:

CLS GETTATO E PERMANENTEMENTE ESPOSTO CONTRO TERRA: 75mm

CALCESTRUZZO ESPOSTO AL TERRENO O ALLE INTEMPERIE:

BARRE 20mm O MAGGIORI 50mm BARRE 12mm O MINORI 40mm

CALCESTRUZZO NON ESPOSTO AL TERRENO O INTEMPERIE:

SOLAI 40mm PARETI 50mm

4. LE SOVRAPPOSIZIONI DI ARMATURE SARANNO IN ACCORDO CON I REQUISITI

DI ACI 318 E LE TABELLE DI LUNGHEZZE DI SOVRAPPOSIZIONE SUI DISEGNI.

5. CALCESTRUZZO GETTATO IN OPERA SARA' CLASSE C35/45:

POSIZIONE f'c 28-gg ARIA RAPP. A/C MAX SLUMP

MAX

PLINTI/

FOND. PARETI 35 MPa 6%+/-1% 0.45 100mm SOLETTE 35 MPa - 0.45 100mm CLS ESTERNO 35 MPa 6%+/-1% 0.45 100mm

6. TUTTE LE ARMATURE PER CLS IN OPERA SARANNO POSIZIONATE CON

PRECISIONE, MANTENUTE, LEGATE E ASSICURATE IN POSIZIONE PRIMA DEL

GETTO IN CLS. TUTTE LE BARRE, SPINOTTI NON DOVRANNO ESSERE

INCASSATI DOPO IL GETTO SALVO DIVERSAMENTE INDICATO NEI DISEGNI.

7. FAR RIFERIMENTO ALLE TAVOLE DELLE ALTRE DISCIPLINE PRIMA DELLA

COSTRUZIONE PER ELEMENTI INCASSATI E PENETRAZIONI NON MOSTRATE

SULLE TAVOLE STRUTTURALI COME RICHIESTO PER ACCOMODARE TUTTE LE

LAVORAZIONI MOSTRATE O SPECIFICATE NEI DOCUMENTI DI CONTRATTO E

ALTRIMENTI NECESSARIE PER LA FORNITURA DI UN'OPERA FUNZIONALMENTE

COMPLETA. RINFORZARE INTORNO ALLE APERTURE COME DA DETTAGLI

STRUTTURALI STANDARD SALVO MOSTRATO DIVERSAMENTE.

8. SMUSSARE DI 0mm TUTTI GLI SPIGOLI ESPOSTI. NON TUTTI GLI SMUSSI

POTREBBERO ESSERE MOSTRATI.

9 BULLONI DI ANCORAGGIO NON SPECIFICATI DAI DISEGNI DI CONTRATTO

SARANNO PROGETTATI E CERTIFICATI DA UN INGEGNERE QUALIFICATO

CONTRATTATO DALL'APPALTATORE IN ACCORDO CON I REQUISITI NORMATIVI

E DI PROGETTO. SOTTOMETTERE COME SHOP DRAWING PER REVISIONE ED

APPROVAZIONE DALL'UFFICIALE CONTRAENTE. COORDINARE POSIZIONE,

DIMENSIONE E INCASSO PRIMA DEL GETTO DI CLS.

10.TUTTI GLI ANCORAGGI POSTI IN OPERA E INSTALLATI SUCCESSIVAMENTE

INDICATI NEI DOCUMENTI STRUTTURALI DOVRANNO ESSERE IN CONFORMITA'

CON L'APPENDICE D DELL'ACI 318 E CAPITOLO 19 DELL'IBC. TUTTI GLI

ANCORAGGI AD ESPANSIONE E ADESIVI DOVRANNO AVERE UN CERTIFICATO

ICC CHE DIMOSTRI UNA CAPACITA' DI CARICO EQUIVALENTE.

11.PRIMA DELL'ISTALLAZIONE DEGLI ANCORAGGI POST-ISTALLATI NEL CLS

L'APPALTATORE DOVRA' INDIVIDUARE L'ARMATURA. NON DANNEGGIARE

L'ARMATURA DEL CLS. NON SARA' ASSOLUTAMENTE PERMESSA LA

SALDATURA DELLE BARRE NE' IL RISCALDAMENTO A CANNELLO PER LA LORO

PIEGATURA SENZA SPECIFICA APPROVAZIONE DELL'UFFICIALE CONTRAENTE.

LAMIERE DI ACCIAIO

1. IL PROGETTO, FABBRICAZIONE ED EREZIONE DELLE LAMIERE SARA' IN

CONFORMITA' CON L' EDIZIONE VIGENTE DELLE SPECIFICHE SDI E DEL

MANUALE DEI DIAFRAMMI SDI.

2. LA LAMIERA DI COPERTURA E' ALTA 55mm X 0.8mm SPESSORE CON

NERVATURE COME MOSTRATO SULLE TAVOLE PROGETTATE PER UN CARICO

ACCIDENTALE SU INDICATO E 0.6 kPa DI CARICO PERMANENTE. LE

PROPRIETA' MINIME DELLA SEZIONE SONO COME DI SEGUITO:

Jy = 60.12 cm4/m, We,inf = 21.86 cm3/m, We,sup = 21.86 cm3/m.

3. LA LAMIERA DOVRA' ESSERE UN DIAFRAMMA COLLEGATO ALLA STRUTTURA

COME MOSTRATO SUI DISEGNI.

4. CONTROSOFFITTI, CORPI ILLUMINANTI, CONDOTTE E ALTRI IMPIANTI NON

DOVRANNO ESSERE MANTENUTI DALLA LAMIERA D'ACCIAIO.

ACCIAIO STRUTTURALE

1. PROPRIETA' DI PROGETTO DELL'ACCIAIO STRUTTURALE:

PROFILI AD H E A T-

UNI 5398, UNI 5397 GRADO

S355 Fy = 355 MPa

PROFILI A L, A C E PIASTRE-

UNI 5398, UNI 5397 GRADO

S275 Fy = 275 MPa

TUBI IN ACCIAIO – UNI 7811 GRADO

S355 Fy = 355 MPa

SEZIONI STRUTTURALI CAVE PROFILATE A FREDDO –

UNI EN 10219 GRADI

S235 Fy = 235 MPa S275 Fy = 275 MPa S355 Fy = 355 MPa

TUBOLARI STRUTTURALI FORMATI A FREDDO –

UNI EN 10219 GRADI

S235 Fy = 235 MPa S275 Fy = 275 MPa S355 Fy = 355 MPa ACCIAIO INOSSIDABILE Fy = 230 MPa

BULLONI – EN 14399 CLASSI

6.8 Fy = 600 MPa

8.8 Fy = 800 MPa

10.9 Fy = 1000 MPa

BARRE DI ANCORAGGIO – GRADI

S275 Fy = 275 MPa

PRESSOPIEGATI IN ACCIAIO MONTANTI/TRAVETTI – GRADI

S235 Fy = 235 MPa S275 Fy = 275 MPa S355 Fy = 355 MPa

2. TUTTE LE SALDATURE E PROCEDURE DI SALTATURA SARANNO EFFETTUATI

IN CONFORMITA' CON LE PRESCRIZIONI APPLICABILI DELL'AISC E DELL'AWS E

NORMATIVE INDICATE IN SPECIFICA. TUTTE LE SALDATURE SARANNO

REALIZZATE CON ELETTRODI E-70XX A IN CONFORMITA' CON AWS PER

ALEAZIONI DI METALLO DA SALDARE SALVO INDICATO DIVERSAMENTE.

3. QUANDO LA DIMENSIONE DELLA SALDATURA A CORDONE D'ANGOLO NON E'

INDICATA, PREDISPORRE LA DIMENSIONE MINIMA SECONDO LE SPECIFICHE

AISC, TABELLA J2.4 OPPURE 5mm, IL VALORE MAGGIORE.

4. TUTTE LE SALDATURE A PENETRAZIONE INDICATE IN PIANTE E SEZIONI

SARANNO A PENETRAZIONE COMPLETA (CJP) SALVO SPECIFICAMENTE

INDICATO COME PENETRAZIONE PARZIALE.

5. LE QUOTATURE SI RITENGONO RISPETTO AGLI ASSI DI PILASTRI E TRAVI,

ALLE SUPERFICI SUPERIORI DI TRAVI E TUBI E FACCE POSTERIORI DI PROFILI

A C E ANGOLARI SALVO DIVERSA INDICAZIONE.

6. TUTTE LE UNIONI IMBULLONATE IN CANTIERE SARANNO REALIZZATE CON

BULLONI M20 EN 14399 CLASSI 6.8, 8.8, 10.9 SALVO INDICATO DIVERSAMENTE.

TUTTE LE UNIONI IMBULLONATE IN CANTIERE SARANNO A SERRAGGIO

NORMALE SALVO INDICATE COME PRECARICATE O A SERRAGGIO

CONTROLLATO. LE UNIONI PRECARICATE O A SERRAGGIO CONTROLLATO

SARANNO REALIZZATE CON RONDELLE DTI. ISTALLARE I BULLONI AD ALTA

RESISTENZA IN ACCORDO ALLE SPECIFICHE PER UNIONI STRUTTURALI DELLA

RCSC USANDO BULLONI ASTM A325 O A490 PER IL TIPO DI UNIONE

SPECIFICATA.

7. ELEMENTI AD ANGOLARI DOPPI SARANNO FORNITI DI PIASTRE DI

IMBOTTITURA INTERMITTENTI COME RICHIESTO DALLA SEZIONE E6 DEL

MANUALE DI CONSTRUZIONI DI ACCIAIO AISC.

S Y

M D

E S

C R

IP

TI

O N

D A

TE

A

P

W12X26

W12X26

TOF x.x

FRAMING SIZE

DIMENSIONE PROFILO

EXISTING FRAMING SIZE

DIMENSIONE PROFILO ESISTENTE

X

BEAM TO BEAM MOMENT CONNECTION

UNIONE A MOMENTO TRAVE-TRAVE

TOP OF FOUNDATION

QUOTA ESTRADOSSO FONDAZIONE

COLUMN GRID MARK

ETICHETTA LINEA ASSE PILASTRO

BEAM TO HSS COLUMN MOMENT CONNECTION

UNIONE A MOMENTO TRAVE-PILASTRO TUBOLARE

NEW WORK KEY NOTE

NOTA CHIAVE LAVORAZIONE NUOVA

DEMOLITION KEY NOTE

NOTA CHIAVE DEMOLIZIONE

TOC x.x TOP OF CONCRETE

QUOTA ESTRADOSSO CLS

TOS x.x TOP OF STEEL

QUOTA ESTRADOSSO ACCIAIO

TOM x.x TOP OF MASONRY

QUOTA ESTRADOSSO MURATURA

x.x TOP OF SLAB SPOT ELEVATION

QUOTA PUNTUALE ESTRAD. SOLAIO

SPAN DIRECTION OF ROOF DECK

DIREZIONE ORDITURA LAMIERA D' ACCIAIO

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E

INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR.

NO.

SHEET

NAVFAC DRAWING

NO.

DES DRW CHK

OF

EPROJECT

NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

Y

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

NAVFAC METRIC DRAWFORM REVISION: 07 AUGUST 2018

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

Y E

N G

IN

E

E R

IN

G

S Y

S T

E M

C O

M M

A N

D

A T

L A

N T

IC

N

O R

F O

L K

V

IR

G

IN

IA

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

A V

IA

N

O A

IR

B

A S

E A

V

IA

N O

, I T

A

LY

A R

E A

A

E N

T R

Y C

O N

T R

O L

P O

IN

T

LET/JSL

DPS

1917 SOUTH 67TH STREET

OMAHA, NE 68106

/6

/2

:2

:5

P M

B

IM

/1

N

A V

F A

C A

D e s ig n A v ia n o

It a ly

/1

-S -G e n e ra l_ v

.r v t

S-003

G E

N E

R A

L S

T R

U C

TU

R

A L

N O

T E

S A

N D

P

LA

N L

E G

E N

D

NO

TE

G

EN

ER

AL

I S

TR

UT

TU

RA

LI

E

LE

GE

ND

A

DI

T

AV

OL

A

SKM

14090081

ARA JMH

22 MARCH, 2021

APPROVED BY SCOTT KIBLER

VIA E-MAIL

1631931

N62470-21-C-0003

A T

L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

RICHARD STEPHENS, PE

JTW

GENERAL NOTES

LEGEND - LEGENDA

PRE-ENGINEERED METAL CANOPY NOTES CONT'D

10.THE FINAL COLUMN BASE REACTIONS, COLUMN LOCATIONS, ANCHOR ROD

SIZES, AND ANCHOR ROD SPACING SHALL BE SUBMITTED TO THE

CONTRACTING OFFICER FOR REVIEW. ALL FOOTINGS, FOUNDATIONS,

ANCHOR RODS, AND PILASTERS HAVE BEEN DESIGNED BASED ON ASSUMED

LOADINGS AND REACTIONS. FOOTINGS AND ANCHOR RODS SHALL BE

VERIFIED AND CONFIRMED BY THE CONTRACTOR’S STRUCTURAL ENGINEER.

LOAD REACTIONS THAT EXCEED THE REACTIONS LISTED PER THE “COLUMN

BASE REACTIONS” TABLES ON SA501 MAY NECESSITATE FOUNDATION

REDESIGN AND RELOCATIONS OF ANCHOR RODS. IF REDESIGN IS REQUIRED,

THE REDESIGN OF THE FOOTINGS AND ANCHOR RODS SHALL BE DONE AND

PAID FOR BY THE CONTRACTOR. THE FOUNDATION SHOP DRAWINGS SHALL

NOT BE SUBMITTED UNTIL THE PRE-ENGINEERED METAL CANOPY SHOP

DRAWINGS, THE COLUMN BASE REACTIONS, AND THE FOUNDATION

VERIFICATION HAVE BEEN APPROVED.

11.THE METAL CANOPY FRAMES AND ALL EXPOSED STRUCTURAL STEEL SHALL

BE GALVANIZED.

12.SEE CONTRACT SPECIFICATION 13 34 19 FOR ADDITIONAL INFORMATION.

SPECIAL STRUCTURAL INSPECTIONS

1. SPECIAL INSPECTIONS AND TESTS SHALL BE BY AN INDEPENDENT TESTING

AND INSPECTION AGENCY EMPLOYED BY THE CONTRACTOR AND APPROVED

BY THE CONTRACTING OFFICER. TEST AND INSPECTION REPORTS SHALL BE

SUBMITTED FOR REVIEW TO THE CONTRACTING OFFICER.

2. SPECIAL INSPECTIONS AND TESTS SHALL BE PERFORMED DURING

CONSTRUCTION IN ACCORDANCE WITH CHAPTER 17 AND SECTION 110 OF

THE 2018 INTERNATIONAL BUILDING CODE, STATEMENT OF SPECIAL

INSPECTION, SCHEDULE OF SPECIAL INSPECTIONS, AND THE CONTRACT

SPECIFICATIONS. THE CONTRACTOR SHALL NOTIFY AND ACCOMMODATE THE

APPLICABLE INSPECTOR DURING APPROPRIATE PHASES OF THE WORK AS

REQUIRED BY EACH TEST AND INSPECTION.

3. SPECIAL INSPECTION, SEE SPECIFICATION SECTION 01 45 35, SPECIAL

INSPECTIONS, STATEMENT OF SPECIAL INSPECTION, AND THE SCHEDULE OF

SPECIAL INSPECTIONS.

POST INSTALLED ANCHORS

1. POST INSTALLED ANCHORS SHALL ONLY BE USED WHERE SPECIFIED ON THE

CONTRACT DRAWINGS. THE CONTRACTOR SHALL OBTAIN APPROVAL FROM

THE CONTRACTING OFFICER BEFORE INSTALLING POST INSTALLED ANCHORS

FOR MISSING OR MISPLACED CAST-IN-PLACE ANCHORS.

2. CARE SHALL BE TAKEN IN PLACING POST– INSTALLED ANCHORS TO AVOID

CONFLICTS WITH THE EXISTING REBAR. HOLES SHALL BE DRILLED AND

CLEANED IN ACCORDANCE WITH THE MANUFACTURER’S WRITTEN

INSTRUCTIONS.

3. SUBSTITUTION REQUESTS FOR PRODUCTS OTHER THAN THOSE SPECIFIED

BELOW, SHALL BE SUBMITTED BY THE CONTRACTOR TO THE CONTRACTING

OFFICER ALONG WITH CALCULATIONS THAT ARE PREPARED AND SEALED BY

A REGISTERED PROFESSIONAL ENGINEER. THE CALCULATIONS SHALL

DEMONSTRATE THAT THE SUBSTITUTED PRODUCT IS CAPABLE OF ACHIEVING

THE PERTINENT EQUIVALENT DESIGN PERFORMANCE VALUES (MINIMUM)

OF THE SPECIFIED PRODUCT USING THE APPROPRIATE DESIGN PROCEDURE

AND/ OR STANDARDS(S). AS REQUIRED BY THE BUILDING CODE. PRODUCT

ICC-ES REPORTS SHALL BE INCLUDED WITH THE SUBMITTAL PACKAGE.

4. UNLESS NOTED OTHERWISE ON PLANS, ACCEPTABLE CONCRETE ANCHORS

PRODUCTS SHALL BE:

a. MECHANICAL ANCHORS FOR USE IN CRACKED AND UNCRACKED

CONCRETE SHALL HAVE BEEN TESTED AND QUALIFIED FOR USE IN

ACCORDANCE WITH ACI 355.2 AND ICC-ES AC193.

b. ADHESIVE ANCHORS FOR USE IN CRACKED AND UNCRACKED CONCRETE

SHALL HAVE BEEN TESTED AND QUALIFIED FOR USE IN ACCORDANCE

WITH ACI 308.

c. CONCRETE SCREW ANCHORS FOR USE IN CRACKED AND UNCRACKED

CONCRETE SHALL HAVE BEEN TESTED AND QUALIFIED FOR USE IN

ACCORDANCE WITH ACI 355.2 AND ICC-ES AC193.

PRE-ENGINEERED METAL CANOPY NOTES

1. RIGID FRAMES SHALL BE SPACED AS INDICATED ON THE DRAWINGS, BUT

OVERALL DIMENSIONS AND CONSTRUCTION DETAILS MAY VARY TO SUIT

MANUFACTURER’S STANDARD DESIGN.

2. THE CANOPY SHALL BE DESIGNED AND FABRICATED IN ACCORDANCE WITH

THE BUILDING CODE LISTED ABOVE AND CONTRACTOR SPECIFICATIONS.

3. THE DESIGN OF THE ANCHOR ROD SIZES, QUANTITIES AND LOCATIONS AS

WELL AS BASE PLATES SHALL BE CALCULATED FOR A PINNED BASE

SUPPORT.

4. THE DIMENSIONS, TOLERANCES OUTLINED IN THE AWS CODE UNDER

WORKMANSHIP AND TOLERANCES APPLICABLE TO HOT ROLLED UNDER THE

AISC “STANDARD MILL PRACTICE” SECTION SHALL BE REQUIRED IN THE

FABRICATION OF THE STEEL CANOPY FRAMES.

5. THE CANOPY FRAMES SHALL BE DESIGNED FOR A MAXIMUM LATERAL

DEFLECTION OF H/200 AT THE HIGHEST CANOPY EAVE HEIGHT FOR THE

BASIC WIND SPEED AND THE SEISMIC PARAMETERS LISTED ABOVE.

6. A COMPLETE DESIGN ANALYSIS THAT IS STAMPED BY A PROFESSIONAL

LICENSED ENGINEER IN THE STATE WHERE THE PROJECT IS LOCATED SHALL

BE SUBMITTED FOR INFORMATION ONLY. THE DESIGN ANALYSIS SHALL

INCLUDE A LIST OF THE DESIGN LOADS, LOADS TRANSMITTED TO THE

FOUNDATIONS, RIGID FRAME DESIGN, MISC BRACING, ANCHOR ROD SIZES,

ANCHOR ROD LAYOUT, LOCATION OF EMBEDDED ITEMS, AND ERECTION

DRAWINGS.

7. THE CANOPY SHALL BE DESIGNED TO SUPPORT ALL MECHANICAL AND

ELECTRICAL EQUIPMENT. ADDITIONAL GIRTS OR PURLINS SHALL BE PLACED

IN CONVENIENT LOCATIONS FOR ATTACHMENT OF MECHANICAL, ELECTRICAL,

AND SOLAR EQUIPMENT.

8. DESIGN LOADS SHALL CONFORM TO THE LIVE, WIND, AND SEISMIC LOAD

PARAMETERS GIVEN ABOVE AND PER THE CONTRACT SPECIFICATIONS. THE

ROOF DEAD LOAD SHALL INCLUDE SELF WEIGHT PLUS A UNIFORM 1kPa

COLLATERAL LOAD. BUILDING DEAD LOADS ARE WEIGHTS OF THE BUILDING

COMPONENTS. LOAD COMBINATIONS SHALL BE IN ACCORDANCE WITH THE

CODES LISTED ABOVE AND MBMA. THE BUILDING STRESSES SHALL BE BY DM

17-01-2018 AND COMPLY WITH AISC SPECIFICATIONS FOR STRUCTURAL

STEEL STRUCTURES.

9. RIGID FRAME ANCHOR ROD SIZES SHALL BE DESIGNED BY THE METAL

CANOPY MANUFACTURER AND FURNISHED BY THE CONTRACTOR. THE

ANCHOR ROD SIZES AND LAYOUT SHALL BE SUBMITTED FOR INFORMATION

ONLY.

GENERAL NOTES

ANCORAGGI POST-ISTALLATI

1. GLI ANCORAGGI POST-ISTALLATI SARANNO USATI SOLO LADDOVE

SPECIFICATO SUI DISEGNI DI CONTRATTO. L'APPALTATORE DOVRA'

OTTENERE L'APPROVAZIONE DELL'UFFICIALE CONTRAENTE PRIMA DI

INSTALLARE ANCORAGGI POST-ISTALLATI AL POSTO DI ANCORAGGI NEL

GETTO MANCANTI O MAL PREDISPOSTI.

2. L'ISTALLAZIONE DEGLI ANCORAGGI POST-ISTALLATI VA ESEGUITA CON

ATTENZIONE PER EVITARE CONFLITTI CON BARRE DI ARMATURA ESISTENTI. I

FORI SARANNO REALIZZATI E PULITI IN ACCORDO CON LE ISTRUZIONI

FORNITE DAL PRODUTTORE.

3. RICHIESTE DI SOSTITUZIONE CON PRODOTTI DIVERSI DA QUELLI SPECIFICATI

DI SEGUITO DOVRANNO ESSERE SOTTOMESSI DALL'APPALTATORE

ALL'UFFICIALE CONTRAENTE INSIEME AI CALCOLI PREPARATI E TIMBRATI DA

UN INGEGNERE QUALIFICATO ABILITATO. I CALCOLI DOVRANNO DIMOSTRARE

CHE IL PRODOTTO IN SOSTITUZIONE SIA CAPACE DI RAGGIUNGERE VALORI DI

PRESTAZIONE EQUIVALENTI DI PROGETTO A QUELLI (MINIMI) DEL PRODOTTO

SPECIFICATO USANDO LE PROCEDURE DI PROGETTO APPROPRIATE E/O

STANDARD COME RICHIESTO DALLE NORMATIVE DI COSTRUZIONE.

CERTIFICATI ICC-ES DOVRANNO ESSERE INCLUSI NEL PACCHETTO DI

SOTTOMISSIONE.

4. SALVO DIVERSAMENTE INDICATO NELLE TAVOLE, GLI ANCORAGGI IN CLS

ACCETTABILI DOVRANNO ESSERE:

a. ANCORAGGI MECCANICI PER USO IN CLS FESSURATO E NON FESSURATO

CHE SIANO STATI TESTATI E QUALIFICATI PER USO IN CONFORMITA' CON

ACI 355.2 E ICC-ES AC193.

b. ANCORAGGI ADESIVI PER USO IN CLS FESSURATO E NON FESSURATO

CHE SIANO STATI TESTATI E QUALIFICATI PER USO IN CONFORMITA' CON

ACI 308.

c. ANCORAGGI AVVITATI IN CLS PER USO IN CLS FESSURATO E NON

FESSURATO CHE SIANO STATI TESTATI E QUALIFICATI PER USO IN

CONFORMITA' CON ACI 355.2 E ICC-ES AC193.

NOTE SULLE PENSILINE PREFABBRICATE

1. I TELAI RIGIDI SARANNO SPAZIATI COME INDICATO NELLE TAVOLE, MA LE

DIMENSIONI TOTALI E I DETTAGLI DI COSTRUZIONE POTREBBERO VARIARE IN

FUNZIONE DEGLI STANDARD DI PROGETTO DEL PRODUTTORE.

2. LA PENSILINA DOVRA' ESSERE PROGETTATA E FABBRICATA IN CONFORMITA'

CON LE NORMATIVE SU INDICATE E LE SPECIFICHE DELL'APPALTATORE.

3. IL PROGETTO DELLE DIMENSIONI DELLE BARRE DI ANCORAGGIO, QUANTITA' E

POSIZIONI COSI' COME LE PIASTRE DI BASE SARANNO CALCOLATE PER UN

SUPPORTO VINCOLATO A CERNIERA.

4. NELLA FABBRICAZIONE DEI TELAI DI ACCIAIO DELLA PENSILINA SARANNO

RICHIESTE DIMENSIONI, TOLLERANZE INDICATE NELLA NORMATIVA AWS SU

LAVORAZIONI E TOLLERANZE APPLICABILI A PROFILI FORMATI A CALDO

SECONDO LA SEZIONE "PRATICHE STANDARD DI FABBRICAZIONE" DELL' AISC.

5. I TELAI DELLA PENSILINA DOVRANNO ESSERE PROGETTATI CON UNA

DEFORMAZIONE LATERALE MASSIMO DI H/200 AL PUNTO PIU' ALTO

DELL'IMPOSTA DELLA PENSILINA PER UNA VELOCITA' BASE DEL VENTO E I

PARAMETRI SISMICI SU ELENCATI.

6. L'ANALISI PROGETTUALE COMPLETA TIMBRATA DA UN INGEGNERE

QUALIFICATO ABILITATO NELLO STATO DOVE E' UBICATO IL PROGETTO SARA'

SOTTOMESSO SOLO PER INFORMAZIONE. LA RELAZIONE PROGETTUALE

DOVRA' INCLUDERE UNA LISTA DEI CARICHI DI PROGETTO, I CARICHI

TRASMESSI ALLE FONDAZIONI, IL PROGETTO DEL TELAIO RIGIDO,

CONTROVENTI VARI, DIMENSIONI DELLE BARRE DI ANCORAGGIO, LA

DISPOSIZIONE DEGLI ANCORAGGI, POSIZIONE DEGLI ELEMENTI INCASSATI E I

DISEGNI DI MONTAGGIO.

7. LA PENSILINA DOVRA' ESSERE PROGETTATA PER SOSTENERE TUTTI GLI

IMPIANTI MECCANICI ED ELETTRICI. ARCARECCI E TRAVI SECONDARIE

DOVRANNO ESSERE POSIZIONATI IN POSIZIONI CONVENIENTI PER IL

COLLEGAMENTO DEGLI IMPIANTI MECCANICI, ELETTRICI E SOLARI.

8. I CARICHI DI PROGETTO DOVRANNO ESSERE CONFORMI AI PARAMETRI DI

CARICO ACCIDENTALI, DA VENTO E DA SISMA FORNITI PRECEDENTEMENTE E

SECONDO LE SPECIFICHE DI CONTRATTO. IL CARICO PERMANENTE DELLA

COPERTURA DOVRA' INCLUDERE IL PESO PROPRIO PIU' UN CARICO

COLLATERALE UNIFORME DI 1 kPa. I CARICHI PERMANENTI SONO I PESI DEI

COMPONENTI DEL FABBRICATO. LE COMBINAZIONI DI CARICO SARANNO IN

ACCORDO CON LE NORMATIVE SU ELENCATE E MBMA. LE TENSIONI NEL

FABBRICATO SARANNO SECONDO IL DM 17-01-2018 E IN CONFORMITA' CON LE

SPECIFICHE AISC PER STRUTTURE IN ACCIAIO STRUTTURALE.

9. LE DIMENSIONI DELLE BARRE DI ANCORAGGIO SARANNO PROGETTATE DAL

PRODUTTORE DELLA PENSILINA DI METALLO E FORNITE DALL'APPALTATORE.

LE DIMENSIONI DELLE BARRE DI ANCORAGGIO E LA DISTRIBUZIONE SARANNO

SOTTOMESSE SOLO PER INFORMAZIONE.

NOTE SULLA PENSILINA PREFABBRICATA (CONT.)

10.LE REAZIONI FINALI ALLA BASE DEI PILASTRI, LE POSIZIONI DEI PILASTRI, LE

DIMENSIONI DELLE BARRE DI ANCORAGGIO E LA SPAZIATURA DELLE BARRE

DI ANCORAGGIO SARA' SOTTOMESSA ALL'UFFICIALE CONTRAENTE PER

REVISIONE. TUTTI I PLINTI, FONDAZIONI, BARRE DI ANCORAGGIO E

BASAMENTI SARANNO PROGETTATI IN BASE AI CARICHI E LE REAZIONI

IPOTIZZATI. I PLINTI E LE BARRE DI ANCORAGGIO SARANNO VERIFICATE E

CONFERMATE DALL'INGEGNERE STRUTTURISTA DELL'APPALTATORE. LE

REAZIONI CHE ECCEDONO QUELLE ELENCATE NELLE TABELLE "REAZIONI DI

BASE DEI PILASTRI" SU TAVOLA 2S-501 POTREBBERO AVERE BISOGNO DI

UNA REPROGETTAZIONE DELLA FONDAZIONE E RIPOSIZIONAMENTO DELLE

BARRE DI ANCORAGGIO. SE UNA RIPROGETTAZIONE FOSSE NECESSARIA, LA

RIPROGETTAZIONE DELLE FONDAZIONI E DELLE BARRE DI ANCORAGGIO

SARA' EFFETTUATA E PAGATA DALL'APPALTATORE. GLI SHOP DRAWINGS

DELLA FONDAZIONE NON SARANNO SOTTOMESSI FINCHE' NON SIANO STATI

APPROVATI GLI SHOP DRAWINGS DELLA PENSILINA E LE VERIFICHE DELLE

REAZIONI DI BASE E LE FONDAZIONI DEI PILASTRI.

11.I TELAI DELLA PENSILINA METALLICA E TUTTE LE STRUTTURE IN ACCIAIO

ESPOSTE SARANNO ZINCATE.

12.VEDI SPECIFICA DI CONTRATTO 13 34 19 PER INFORMAZIONI AGGIUNTIVE.

SPECIAL STRUCTURAL INSPECTIONS

1. SPECIAL INSPECTIONS AND TESTS SHALL BE BY AN INDEPENDENT TESTING

AND INSPECTION AGENCY EMPLOYED BY THE CONTRACTOR AND APPROVED

BY THE CONTRACTING OFFICER. TEST AND INSPECTION REPORTS SHALL BE

SUBMITTED FOR REVIEW TO THE CONTRACTING OFFICER.

2. SPECIAL INSPECTIONS AND TESTS SHALL BE PERFORMED DURING

CONSTRUCTION IN ACCORDANCE WITH CHAPTER 17 AND SECTION 110 OF

THE 2018 INTERNATIONAL BUILDING CODE, STATEMENT OF SPECIAL

INSPECTION, SCHEDULE OF SPECIAL INSPECTIONS, AND THE CONTRACT

SPECIFICATIONS. THE CONTRACTOR SHALL NOTIFY AND ACCOMMODATE THE

APPLICABLE INSPECTOR DURING APPROPRIATE PHASES OF THE WORK AS

REQUIRED BY EACH TEST AND INSPECTION.

3. SPECIAL INSPECTION, SEE SPECIFICATION SECTION 01 45 35, SPECIAL

INSPECTIONS, STATEMENT OF SPECIAL INSPECTION, AND THE SCHEDULE OF

SPECIAL INSPECTIONS.

S Y

M D

E S

C R

IP

TI

O N

D A

TE

A

P

NOTES:

1. ALL REBAR SPLICE LENGTHS SHALL BE AS SHOWN UNDER HEADING "VERTICAL" EXCEPT

IF SPLICED BARS ARE HORIZONTAL BARS WITH 300mm OR MORE CONCRETE BELOW.

THEN SPLICE LENGTH SHALL BE AS SHOWN UNDER HEADING "OTHER".

2. AT SPLICES THE BAR SPACING IS THE CENTER TO CENTER DISTANCE BETWEEN

ADJACENT REBARS.

3. ALL SPLICES SHALL BE CONTACT SPLICES AND WIRED TOGETHER.

4. NO WELDED OR MECHANICAL SPLICES ARE PERMITTED UNLESS INDICATED OTHERWISE.

5. UNLESS OTHERWISE SHOWN, SPLICES FOR BOTTOM REINFORCING BARS IN BEAMS AND

SLABS SHALL BE CENTERED OVER THE SUPPORTS. SPLICES FOR TOP REINFORCING

BARS SHALL BE LOCATED ON CENTERLINE OF SPAN.

MINIMUM LAP SPLICE LENGTHS f'c = 35 MPa

BAR

BARRA

LAPS FOR BARS SPACED

GREATER THAN MIN BAR SPACING

SOVRAPPOSIZIONI PER BARRE A

DISTANZA MAGGIORE DEL MINIMO

LAPS FOR BARS SPACED CLOSER

THAN MIN BAR SPACING

SOVRAPPOSIZIONI PER BARRE A

DISTANZA MINORE DEL MINIMO

VERTICAL VERTICALI OTHER ALTRE

* MIN BAR

SPACING

DISTANZA

MIN. TRA

BARRE

Ø10

Ø12

Ø16

Ø20

Ø24

75mm

75mm

100mm

100mm

400mm 450mm

450mm400mm

75mm

500mm 600mm 650mm500mm

600mm 750mm 1250mm900mm

700mm 900mm 1450mm1100mm

1050mm 1400mm 1950mm1500mm

LUNGHEZZE DI SOVRAPPOSIZIONE MINIME f'c=35MPa

VERTICAL VERTICALI OTHER ALTRE

NOTE:

1. TUTTE LE LUNGHEZZE DI SOVRAPPOSIZIONE DELLE BARRE DOVRANNO ESSERE COME INDICATO SOTTO IL TITOLO "VERTICALE" SALVO SE LE BARRE SOVRAPPOSTE SONO ORIZZONTALI CON ALMENO 300mm O PIU' DI CLS AL DI SOTTO. IN QUEL CASO LA LUNGHEZZA DI SOVRAPPOSIZIONE SARA' COME

INDICATO NELLA COLONNA "ALTRE".

2. * NELLE SOVRAPPOSIZIONI LA DISTANZA TRA LE BARRE E' TRA GLI ASSI DI BARRE ADIACENTI.

3. TUTTE LE SOVRAPPOSIZIONI SARANNO IN CONTATTO E LEGATE INSIEME.

4. NON SONO PERMESSE SALDATURE O SOVRAPPOSIZIONI MECCANICHE SALVO INDICATO DIVERSAMENTE.

5. SALVO DIVERSA INDICAZIONE LE SOVRAPPOSIZIONI TRA BARRE DI ARMATURA INFERIORI NELLE TRAVI E

NEI SOLAI SARANNO CENTRATE SUI SUPPORTI. SOVRAPPOSIZIONI PER BARRE SUPERIORI SARANNO

SITUATE NEL CENTRO DELLE CAMPATE.

RECTANGULAR OPENING DETAIL

DETTAGLIO TIPICO FORO RETTANGOLARE

CIRCULAR OPENING DETAIL

DETTAGLIO TIPICO FORO CIRCOLARE

2- Ø16 X 1200mm EACH

FACE TYP 4 LOCATIONS

ADDITIONAL REINF

SEE NOTE 1

CL SYMM ABOUT OPENING

CL SYMM ABOUT OPENING

SIMMETRICO RISPETTO

AL FORO

NOTES:

1. PROVIDE ADDITIONAL REINFORCING THE SAME SIZE AS DISCONTINUOUS

REINFORCEMENT AT OPENING. QUANTITY OF REINFORCING IN EACH

DIRECTION SHALL BE EQUAL TO OR ONE GREATER THAN THE NUMBER OF

DISCONTINUOUS BARS. PLACE 1/2 OF ADDITIONAL REINFORCING BARS

EACH SIDE OF OPENING, PLACE ADDITIONAL REINFORCEMENT AT 75mm OC

(TYPICAL BOTH DIRECTIONS AND ALL LAYERS OF REINFORCEMENT). START

FIRST BAR 50mm CLEAR TO OPENING.

2. EXTEND ADDITIONAL REINFORCING BEYOND EDGE OF OPENING AS SHOWN

ABOVE. ADDITIONAL BARS MAY TERMINATE AT THE END OF THE WALL WITH

A STANDARD HOOK WHERE THE LENGTH OF THE WALL WILL NOT PERMIT

BARS TO EXTEND AS SHOWN ABOVE.

3. TYPICAL WALL OR SLAB REINFORCING NOT SHOWN FOR CLARITY. TERMINATE

TYPICAL REINFORCING 50mm CLEAR TO OPENING.

4. OPENINGS 300mm OR LESS IN SLABS AND WALLS, NO EXTRA REBARS ARE

REQUIRED UNLESS SHOWN OTHERWISE. TYPICAL REINFORCING SHALL BE

RESPACED (NOT CUT) TO ALLOW FOR OPENINGS TO BE MADE.

5. UNLESS SHOWN OTHERWISE ON DRAWINGS, PROVIDE EXTRA REINFORCING

AROUND OPENINGS AS SHOWN AND INDICATED ABOVE.

6. PROVIDE ADDITIONAL DOWELS PER NOTE 1 ABOVE FOR ALL OPENINGS NEAR

THE FLOOR SLAB, BASE SLAB, OR CORNERS.

L/2 +

LAP LENGTH, TYP W/2

W /2

LA

P L

E N

G

TH

, T Y

P L/

L/

D /2

LA

P L

E N

G

TH

, T Y

P D

D/2 +

LAP LENGTH, TYP

L/2 + LUNGH.

ANCORAGGIO TIP.

2 Ø16 X 1200mm AD OGNI

FACCIA TIP. 4 POSIZIONI

CL SYMM ABOUT OPENING

SIMMETRICO RISPETTO

AL FORO

D/2 + LUNGH.

ANCORAGGIO TIP.

SIMMETRICO RISPETTO AL

FORO

W /2

L

U N

G H

A

N C

O R

A G

G

IO

T

IP

D /2

L

U N

G H

A

N C

O R

A G

G

IO

T

IP

NOTE:

1. PREDISPORRE ARMATURA AGGIUNTIVA DELLA STESSA DIMENSIONE DELL'ARMATURA

DISCONTINUA IN CORRISPONDENZA DELLE APERTURE. LA QUANTITA' DI ARMATURA IN

OGNI DIREZIONE DOVRA' ESSERE UGUALE O MAGGIORE AL NUMERO DELLE BARRE

DISCONTINUE. POSIZIONARE 1/2 DELLE BARRE DI ARMATURA AGGIUNTIVA A CIASCUN

LATO DEL FORO, POSIZIONARE ARMATURA AGGIUNTIVA A INTERASSE 75mm (TIPICA

NELLE DUE DIREZIONI E TUTTI GLI STRATI DI ARMATURA). ISTALLARE LA PRIMA BARRA

50mm DAL BORDO DELL'APERTURA.

2. ESTENDERE L'ARMATURA AGGIUNTIVA OLTRE IL BORDO DEL FORO COME SU INDICATO.

BARRE AGGIUNTIVE POSSONO TERMINARE ALLA FINE DEL MURO CON UN GANCIO

STANDARD LADDOVE LA LUNGHEZZA DEL MUTO NON PERMETTA ALLE BARRE DI

ESTENDERSI OLTRE COME SU MOSTRATO.

3. ARMATURA TIPICA DELLA PARETE O SOLAIO NON MOSTRATA PER CHIAREZZA.

TERMINARE ARMATURA TIPICA 50mm DAL BORDO DEL FORO.

4. PER FORI DI 300mm O MENO NEI SOLAI E NELLE PARETI NON SONO RICHIESTE

BARRE AGGIUNTIVE SALVO DIVERSA INDICAZIONE. L'ARMATURA TIPICA SARA'

RIDISTRIBUITA (NON TAGLIATA) PER PERMETTERE LA REALIZZAZIONE DEL FORO.

5. SALVO DIVERSAMENTE INDICATO SULLE TAVOLE, PREDISPORRE ARMATURA

AGGIUNTIVA INTORNO AI FORI COME MOSTRATO SU.

6. DISPORRE BARRE DI ANCORAGGIO AGGIUNTIVE COME DA NOTA 1 SOPRA TUTTI I FORI

VICINO AL SOLAIO DI PIANO, BASE O ANGOLI.

STD HOOK

GANCIO STANDARD

STD HOOK

GANCIO STANDARD

NOTES:

1. ALL HOOKS SHALL BE STD 90 DEGREE HOOKS.

2. OPTIONAL LAP LOCATION. APPLIES TO BOTH DOUBLE AND SINGLE LAYER

CONDITIONS TYP.

NOTE:

1. TUTTI I GANCI SARANNO GANCI STANDARD A 90 GRADI.

2. POSIZIONE OPZIONALE DELLA SOVRAPPOSIZIONE. APPLICABILE A CONDIZIONI

CON ARMATURA IN STRATO SINGOLO E DOPPIO, TIP.

HOOK

ALTERNATE DIRECTION OF HOOKS

SEE DRAWINGS FOR REINF SIZE

AND LOCATION, TYP

SEE NOTE 2

VEDI NOTA 2

LA

P

S P

LI

C

E m m

OPTIONAL

LAP

1220mm

MIN, TYP

LAP SPLICE + 150mm

SOVRAPPOSIZIONE +150mm

S O

V R

A P

P O

S

IZ

IO

N

E

+1 m m

ALTERNARE DIREZIONE DEI GANCI

GANCIO

1220mm

MIN TIP.

SOVRAPP.

OPZIONALE

VEDI DISEGNI PER DIMENSIONI E

POSIZIONE DELL'ARMATURA, TIP.

OPTIONAL

CONST JOINT

CONCRETE FOOTING

FONDAZIONE IN CLS

GIUNTO DI COSTR.

OPZIONALE

OPTIONAL

CONST JOINT

CONCRETE FOOTING

FONDAZIONE IN CLS

GIUNTO DI COSTR.

OPZIONALE

INTERNAL CORNER

ANGOLO INTERNO

DISCONTINUOUS JOINT INTERSECTION

INTERSEZIONE GIUNTO DISCONTINUO

2- Ø12 x 600mm LONG 50mm BELOW SURFACE

2- Ø12 x 600mm LONG 50mm BELOW SURFACE

SLAB EDGE

BORDO SOLETTA

CJ

2- Ø12 x 600mm DI LUNG.

50mm AL DI SOTTO

DELLA SUPERFICIE

2- Ø12 x 600mm DI LUNG.

50mm AL DI SOTTO

DELLA SUPERFICIE

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E

INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR.

NO.

SHEET

NAVFAC DRAWING

NO.

DES DRW CHK

OF

EPROJECT

NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

Y

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

NAVFAC METRIC DRAWFORM REVISION: 07 AUGUST 2018

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

Y E

N G

IN

E

E R

IN

G

S Y

S T

E M

C O

M M

A N

D

A T

L A

N T

IC

N

O R

F O

L K

V

IR

G

IN

IA

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

A V

IA

N

O A

IR

B

A S

E A

V

IA

N O

, I T

A

LY

A R

E A

A

E N

T R

Y C

O N

T R

O L

P O

IN

T

LET/JSL

DPS

1917 SOUTH 67TH STREET

OMAHA, NE 68106

/6

/2

:2

:5

P M

B

IM

/1

N

A V

F A

C A

D e s ig n A v ia n o

It a ly

/1

-S -G e n e ra l_ v

.r v t

S-501

TY

P

IC

A

L S

T R

U C

TU

R

A L

C O

N C

R E

T E

D E

TA

IL

S

DE

TT

AG

LI

S

TR

UT

TU

RA

LI

T

IP

IC

I N

EL

CA

LC

ES

TR

UZ

ZO

SKM

14090082

ARA JMH

22 MARCH, 2021

APPROVED BY SCOTT KIBLER

VIA E-MAIL

1631931

N62470-21-C-0003

A T

L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

RICHARD STEPHENS, PE

JTW

NOT TO SCALE

NON IN SCALA

C1

CONCRETE REINFORCING LAP SPLICE SCHEDULE

NOT TO SCALE

NON IN SCALA

B3

EXTRA REINFORCING AROUND OPENINGS

NOT TO SCALE

NON IN SCALA

A1

TYPICAL CONCRETE WALL

CORNER & INTERSECTION REINF

NOT TO SCALE

NON IN SCALA

B2

TYPICAL FOOTING

REINFORCING @ CORNER

NOT TO SCALE

NON IN SCALA

A2

TYPICAL FOOTING

REINFORCING @ INTERSECTION

NOT TO SCALE

NON IN SCALA

A3

TYPICAL SLAB ON GRADE REINFORCING DETAILS

TABELLA SOVRAPPOSIZIONI DELL'ARMATURA NEL CALCESTRUZZO NON IN SCALA

ARMATURA TIPICA

D'ANGOLO DI FONDAZIONE

ARMATURA AGGIUNTIVA INTORNO ALLE APERTURE

ARMATURA TIPICA D'ANGOLO E

INTERSEZIONE DI PARETI IN CLS

ARMATURA TIPICA D'INTERSEZIONE

DI FONDAZIONE

DETTAGLI D'ARMATURA TIPICA NELLA SOLETTA A TERRA

S Y

M D

E S

C R

IP

TI

O N

D A

TE

A

P

13mm WIDE GROOVE W/ BACKER ROD

AND SEALANT AT EXPOSED FLOORS

SLAB ON GRADE

13mm EXP JT MATERIAL

MATERIAL GIUNTO

DILATAZ. 13mm

FACE OF WALL

SUPERFICIE PARETE

AT COLUMN

IN CORRISPONDENZA DEI PILASTRI

13mm WIDE x 13mm DEEP GROOVE

W/ SEALANT AT EXPOSED FLOORS

COLUMN

PILASTRO

"T

C

LR

GIUNTO LARGO 13mm CON CORDONE

DI SIGILLATURA E SIGILLANTE A

PAVIMENTI ESPOSTI

SOLETTA A TERRA GIUNTO LARGO 13mm CON CORDONE

DI SIGILLATURA E SIGILLANTE A

PAVIMENTI ESPOSTI

DIS

T.75 mm

85 MIN

AS REQ'D SEE NOTE 2 BELOW

COME RICHIESTO VEDI NOTA 2

SOTTO

Ø12/300 EW

Ø12/300 DUE DIREZ.

NOTES:

1. PROVIDE ABOVE PAD UNDER ALL ELECTRICAL AND MECHANICAL EQUIPMENT SUPPORTED ON

STRUCTURAL SLABS. ALSO PROVIDE FOR EQUIPMENT WEIGHING LESS THAN 2270kg

WHICH ARE SUPPORTED ON GRADE OR WHERE SPECIFICALLY NOTED ON PLANS.

2. PAD THICKNESS SHALL BE THE LARGER OF SLAB THICKNESS PLUS 90mm PROVIDE AN ADDITIONAL LAYER OF 12@300mm EACH WAY WITH 40mm CLEAR TOP AND BOTTOM FOR EACH 200mm ADDITIONAL PAD THICKNESS EXCEEDING THE 85mm MINIMUM THICKNESS.

ALTERNATIVELY, THICKEN SLAB ON GRADE BELOW EQUIPMENT PAD AS REQD TO MAINTAIN

MIN 75mm COVER ON ANCHOR BOLTS.

PAD NOTES:

1. ABOVE PAD DETAILS APPLY FOR SUPPORT OF ALL EQUIPMENT UNLESS INDICATED OTHERWISE

ON THE DRAWINGS.

2. 150mm MINIMUM PAD EDGE DIMENSION TO EQUIPMENT AB APPLIES FOR ALL EQUIPMENT SUPPORT PADS.

Ø12 CLOSED TIE ADDL CONT @ PERIMETER

STAFFE CHIUSE Ø12 AGGIUNTIVE CONTINUE

AL PERIMETRO

CONCRETE SURFACE SHALL BE CLEAN, FREE OF LAITANCE,

ROUGHENED TO A 6mm AMPLITUDE, & COATED W/ BONDING AGENT

LA SUPERFICIE DI CALCESTRUZZO DOVRA' ESSERE PULITA DA

POLVERI E RESA SCABRA CON LARGHEZZA 6mm E TRATTATA CON

UN AGENTE ADESIVO

20mm CHAMFER TYP SMUSSATURA TIP. 20mm

SEE PLAN FOR SLAB THICKNESS & REINFORCING

VEDI PIANTA PER SPESSORE SOLETTE E ARMATURA

EQUIP BASE

BASE

MACCHINA

Ø12/300 TYP PLACE VERT LEG IN 20mm DIA

DRILLED HOLE FILLED W/NON-SHRINK GROUT

OR Ø12/300 HOOKED EE CAST INTO SLAB

200mm LEG TYP PIEGATURA TIP. 200mm

EQUIP AB

ANCOR.

MACCHINA

100 MIN

150 MIN

C

LR

Ø12/300 TIP. POSIZIONARE PIEGA VERTICALE IN FORO

20mm DIAM. RIEMPITO CON MALTA ANTIRITIRO O Ø12/300

PIEGATO ALL'ESTREMITA' E GETTATO NELLA SOLETTA

NOTE:

1. PREDISPORRE TUTTE LE MACCHINE DI IMPIANTI ELETTRICI E MECCANICI MANTENUTI DA SOLAI STRUTTURALI SU BASAMENTI. FORNIRE ANCHE PER IMPIANTI CON PESO MINORE DI 2270 kg CHE SONO POGGIATI SUL TERRENO O

LADDOVE SPECIFICAMENTE ANNOTATO SULLE TAVOLE.

2. LO SPESSORE DEI BASAMENTI SARA' IL MAGGIORE DELLO SPESSORE DEL SOLAIO PIU' 90mm. FORNIRE UNO STRATO DI ARMATURA AGGIUNTIVA F12/300mmNELLE DUE DIREZIONI CON 40mm DI DISTANZA LIBERA SUPERIORE E INFERIORE PER OGNI 200mm DI SPESSORE DI BASAMENTO AGGIUNTIVO IN ECCESSO DI 85mm DI SPESSORE MINIMO. IN ALTERNATIVA, INSPESSIRE LA SOLETTA A TERRA AL DI SOTTO DELLA MACCHINA COME NECESSARIO PER MANTENERE 75mm DI COPRIFERRO MIN SULLE BARRE DI ANCORAGGIO.

NOTE BASAMENTI:

1. I DETTAGLI SUI BASAMENTI SONO APPLICABILI PER SUPPORTI DI TUTTE LE MACCHINE SALVO DIVERSA

INDICAZIONE SUI DISEGNI.

2. LA DIMENSIONE MINIMA DI 150mm DAL BORDO DEL BASAMENTO ALLA MACCHINA E' APPLICABILE A TUTTI I

SUPPORTI PER LE MACCHINE.

25mm MIN NON-SHRINK GROUT MALTA ANTIRITIRO 25mm MIN

AS INDICATED ON DWGS OR AS REQUIRED

BY EQUIPMENT FURNISHED 200mm MIN (UNO)

NOTES:

1. SEE PAD NOTES AT DETAIL C3 THIS SHEET.

2. PROVIDE PAD UNDER ELECTRICAL AND MECHANICAL EQUIPMENT

WEIGHING MORE THAN 2300kg, AND SUPPORTED ON GRADE

UNLESS NOTED OTHERWISE ON PLANS.

3. FOR EQUIPMENT FOUNDATIONS OUTSIDE ON GRADE SEE DETAIL C6

THIS SHEET.

EQUIPMENT BASE

BASE MACCHINA

Ø16/300 T&B

Ø16/300 SUP. E INF.

DOUBLE NUT

DOPPIO DADO

1:1 SLOPE TYP

TIP. PENDENZA 1:1

13mm EXP JT ALL AROUND GIUNTO DILATAZIONE 13mm INTORNO

ANCHOR BOLT

TIRAFONDO

SEE PLANS FOR SLAB THICKNESS AND REINFORCING

VEDI PIANTE PER SPESSORE SOLETTA E ARMATURA

Ø12 CLOSED TIES @ 150mm STAFFE Ø12 /150mm CHIUSE

50 CLR

100 MIN ALL AROUND

150 MIN

C

LR

100 MIN INTORNO

COME INDICATO SUI DISEGNO O COME

RICHIESTO DALLA MACCHINA FORNITA

200mm MIN (SALVO DIV. INDIC.)

NOTE:

1. VEDI NOTE BASAMENTI SUL DETTAGLIO C3 DI QUESTA TAVOLA.

2. FORNIRE BASAMENTI AL DI SOTTO DI IMPIANTI MECCANICI ED

ELETTRICI CON PESO MAGGIORE DI 2300kg E POGGIATI A TERRA S

ALVO DIVERSAMENTE INDICATO SUI DISEGNI.

3. PER FONDAZIONI DI MACCHINE NON POGGIATE A TERRA

VEDI DETTAGLIO C6 SU QUESTA TAVOLA.

NOTES:

1.

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .