This is a technical bid specification document (#5430-0228448) from the California Department of Fish and Wildlife for the procurement of custom fish hauling tanks. The specification details requirements for two types of tanks: a 250-gallon single-compartment tank for Mad River and a 400-gallon single-compartment tank for Iron Gate Hatchery. Both tanks are to be mounted on flatbed trucks and used to transport and plant fish in California waters. The tanks must be newly built, fully welded, and leak-free, constructed with aluminum 5052 material featuring double-walled insulation, foam board insulation, and specific requirements for access lids, drain/discharge systems, oxygen delivery systems, and electrical components.
The technical requirements specify detailed construction parameters including wall thicknesses, insulation requirements, aerator systems, oxygen diffusers, and electrical control systems. Both tanks require specific accessories such as oxygen bottle holders, support tabs, grab rails, sight gauges, and picking eyes. The 250-gallon tank requires an 8-inch knife valve discharge system, while the 400-gallon tank requires a pneumatic knife valve discharge system with dimensions between 18"x12" and 18"x16". Both systems must include comprehensive oxygen delivery systems with pressure monitoring, air vents, aerators, and flow meters. The document does not specify pricing terms, set-asides, or funding requirements.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Att._2_Admin_Requirements.docx | DOCX document | |
| RFQ_3600-0000033763_CDFW_Fish_Hauling_Tanks.pdf | ||
| Att._1_Appendix_A_-_Bid_Specification.pdf | ||
| Att._2_Exhibit_A-Customer_Reference_Form_.docx | DOCX document | |
| Att._4_Narrative_Response.docx | DOCX document | |
| APP_Cover_Page.doc | DOC document | |
| Att._3_Cost_Worksheet.xlsx | XLSX spreadsheet | |
| Att._5_Work_Authorization_Form.docx | DOCX document | |
| Att._6_Shipping_List.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
State of California Bid Specification #5430-0228448
Fish Hauling Tanks Department of Fish and Wildlife
BU 3600 Event ID 0000033763
Attachment 1 baafsdadf
Wang, T Page 1 of 7 Dec 19, 2024
Table of Contents Table of Contents
1.0 Scope
2.0 Applicable Laws and Standards
2.1 Laws, Regulations, Policies
2.2 Standards
3.0 Technical Requirements
3.1 250 Gallon Tank, One Compartment (Mad River)
3.1.1. Tank Construction
3.1.2. Access Lid
3.1.3. Drain/Discharge
3.1.4. Oxygen Delivery and Aeration
3.1.5. Electrical System
3.2 400 Gallon Tank, One Compartment (Iron Gate Hatchery)
3.2.1. Tank Construction
3.2.2. Access Lid
3.2.3. Drain/Discharge
3.2.4. Oxygen Delivery and Aeration
3.2.5. Electrical System
3.2.6. Accessories
Fish Hauling Tanks Department of Fish and Wildlife
BU 3600 Event ID 0000033763
Attachment 1 baafsdadf
Wang, T Page 2 of 7 Dec 19, 2024
1.0 SCOPE
This Bid Specification #5430-34359 defines the requirements for custom fish hauling tanks (henceforth referred to as “tanks”) that will be mounted on flatbed trucks and used by the California Department of Fish and Wildlife to transport and plant fish in California waters.
2.0 APPLICABLE LAWS AND STANDARDS
Laws, regulations, policies, and standards listed in this section form a part of this bid specification as cited in the text.
2.1 LAWS, REGULATIONS, POLICIES
None listed.
2.2 STANDARDS
None listed.
3.0 TECHNICAL REQUIREMENTS
Tanks must be newly built, fully welded, and free from leaks. Figures found in Appendix A referenced throughout the text are for illustration purposes, the text requirements hereafter take precedence over the figures.
The minimum total tank capacity was approximated by multiplying exterior dimensions to determine volume after accounting for inner wall, outer wall, and insulation thickness (minus 3.75 inches to length and width). The change in volume from the 2-inch sloped floor was approximated by subtracting 5.75 inches from height (3.75 inches + 2 inches).
The resulting in3 is converted to gallons (231 in3 = 1 gallon).
3.1 250 GALLON TANK, ONE COMPARTMENT (MAD RIVER)
3.1.1. TANK CONSTRUCTION
a. Exterior dimensions (length x width x height): 43 inches x 43 inches x 34 inches
b. Total capacity: ≥ 250 gallons.
c. Number of compartments: One.
d. Walls, floor, and insulation
i. Double-walled with insulation.
(1) Insulation: 1.5-inch foam board.
(2) Inner wall thickness: 0.25-inch.
(3) Outer wall thickness: 0.125-inch.
ii. Material: Aluminum 5052.
iii. Floor: 2-inch double sloped bottom constructed with false flooring.
e. Exterior paint: White.
Fish Hauling Tanks Department of Fish and Wildlife
BU 3600 Event ID 0000033763
Attachment 1 baafsdadf
Wang, T Page 3 of 7 Dec 19, 2024
3.1.2. ACCESS LID
a. Dimensions (length x width): 38 inches x 24 inches
b. Insulation: 1.5-inch foam board.
c. Placement: Set centered along the width, 5-inch from back of tank.
d. Toggle clamps: Two.
e. Hinge: Front.
f. Lid seal material: Rubber.
g. Lid stops: Installed to prevent lid from falling when open and rest at a 45° angle.
h. Lid handle shape: D-handle.
3.1.3. DRAIN/DISCHARGE
a. Discharge point: Rear.
b. Discharge valve: One 8-inch knife valve.
c. Hose fitting: 8-inch Ring-Lock adapter, dust cap and locking ring.
(1) Ring-lock material: Aluminum.
d. Drain valve: One 2-inch valve.
3.1.4. OXYGEN DELIVERY AND AERATION
a. Oxygen pressure monitoring system: Included and mounted to the tank’s exterior.
b. Air vents
i. Type: AV300.
ii. Quantity: Two.
c. Aerators
i. Voltage: 12 volt.
ii. Pump capacity: ≥ 75 gallons per minute (GPM).
iii. Quantity: One aerator.
iv. Toggle clamps: Two clamps per aerator.
Reference brand/model number: Fresh-Flo TT or equivalent.
d. Oxygen diffusers (air stones)
i. Size: ≥ 12 inches.
ii. Quantity: Two.
iii. Placement: Mounted under the false floor.
iv. Flow rate: ≥ 4.5 liters per minute (LPM).
https://www.freshflo.com/transport-aerators/
Fish Hauling Tanks Department of Fish and Wildlife
BU 3600 Event ID 0000033763
Attachment 1 baafsdadf
Wang, T Page 4 of 7 Dec 19, 2024
Reference brand/model: Pentair Point Four Micro Bubble Diffuser - 1DMBDC300 or equivalent.
e. Flow meters
i. Quantity: Two.
ii. Flow rate: 0 – 15 LPM.
iii. Placement: Front of tank on driver’s side.
f. Oxygen regulator quantity: One.
g. Oxygen pressure switch: One, rated 15 pounds per square inch (psi).
3.1.5. ELECTRICAL SYSTEM
a. System: Fuses for aerators and all electrical components, wired for 12 volts.
b. Main electrical control box (See Appendix A Figure 1)
i. Weather tight.
ii. Installed on the exterior passenger’s side front wall.
iii. Green indicator lights and switches for aerators.
iv. 2-inch red LED low oxygen indicator:
(1) Visible from the truck’s rearview mirror.
(2) Alerts the driver when tank pressure is low.
3.1.6 Accessories
c. Oxygen bottle holder
i. Style: Double bottle.
ii. Orientation: Horizontal.
d. Support tabs: 2 inches x 2 inches x 0.25 inches mounting angle along front and back of tank.
e. Grab rails
i. Top: Installed on top of tank on both sides, along the length at 4-inch high.
ii. Back: Installed on either side of discharge, from top to bottom 4-inch out.
f. Sight gauge with protection wings
i. Quantity: One gauge.
ii. Placement: Rear exterior wall of tank.
g. Picking eyes
i. Quantity: Four.
ii. Size: 0.375-inch.
iii. Placement: One installed on each corner on the tank’s top.
https://pentairaes.com/point-four-micro-bubble-diffusers-mbd.html
Fish Hauling Tanks Department of Fish and Wildlife
BU 3600 Event ID 0000033763
Attachment 1 baafsdadf
Wang, T Page 5 of 7 Dec 19, 2024
h. Lifting: Forklift tubes.
3.2 400 GALLON TANK, ONE COMPARTMENT (IRON GATE HATCHERY)
3.2.1. TANK CONSTRUCTION
a. Exterior dimensions (length x width x height): 60 inches x 48 inches x 43 inches
b. Total capacity: ≥ 400 gallons.
c. Number of compartments: One.
d. Walls, floor, and insulation
i. Double-walled with insulation.
(1) Insulation: 1.5-inch foam board.
(2) Inner wall thickness: 0.25-inch.
(3) Outer wall thickness: 0.125-inch.
ii. Material: Aluminum 5052.
iii. Floor: 2-inch double sloped bottom constructed with false flooring.
e. Exterior paint: White.
3.2.2. ACCESS LID
a. Dimensions (length x width): 44 inches x 36 inches
b. Insulation: 1.5-inch foam board.
c. Placement: Centered.
d. Toggle clamps: Two.
e. Hinge: Front.
f. Lid seal material: Rubber.
g. Lid stops: Installed to prevent lid from falling when open and rest at a 45° angle.
h. Lid handle shape: D-handle.
3.2.3. DRAIN/DISCHARGE
a. Discharge point: Rear.
b. Discharge valve
i. Quantity: One.
ii. Minimum Dimensions (length x width): 18-inch x 12-inch.
iii. Maximum Dimensions (length x width): 18-inch x 16-inch.
iv. Type: Pneumatic knife valve.
Fish Hauling Tanks Department of Fish and Wildlife
BU 3600 Event ID 0000033763
Attachment 1 baafsdadf
Wang, T Page 6 of 7 Dec 19, 2024
c. Hose fitting: One ring-lock adapter, dust cap and locking ring matching discharge valve width in diameter.
i. Ring-lock material: Epoxy coated steel.
d. Additional discharge pipes
i. Include two 6.5-feet long pipes matching discharge valve width in diameter.
ii. Include support chain and attachment point on the ends of the pipe.
e. Drain valve: One 2-inch valve.
3.2.4. OXYGEN DELIVERY AND AERATION
a. Oxygen pressure monitoring system: Included and mounted to the tank’s exterior.
b. Air vents
i. Type: AV300.
ii. Quantity: Two.
c. Aerators
i. Voltage: 12 volt.
ii. Pump capacity: ≥ 75 GPM.
iii. Quantity: Two.
iv. Toggle clamps: Two clamps per aerator (four total).
Reference brand/model number: Fresh-Flo TT or equivalent.
d. Oxygen diffusers (air stones)
i. Size: ≥ 12 inches.
ii. Quantity: Two.
iii. Placement: Mounted under the false floor.
iv. Flow rate: ≥ 4.5 LPM.
Reference brand/model: Pentair Point Four Micro Bubble Diffuser - 1DMBDC300 or equivalent.
e. Flow meters
i. Quantity: Four.
ii. Flow rate: 0 – 15 LPM.
iii. Placement: Front of tank on driver’s side.
f. Oxygen regulator quantity: One.
g. Oxygen manifold
i. Quantity: One.
https://www.freshflo.com/transport-aerators/
Fish Hauling Tanks Department of Fish and Wildlife
BU 3600 Event ID 0000033763
Attachment 1 baafsdadf
Wang, T Page 7 of 7 Dec 19, 2024
ii. Ports: Four (one inlet, two outlet, one port for pressure monitor).
3.2.5. ELECTRICAL SYSTEM
a. System: Fuses for aerators and all electrical components, wired for 12 volts.
b. Main electrical control box (See Appendix A Figure 1)
i. Weather tight.
ii. Installed on the exterior driver’s side front wall.
iii. Green indicator lights and switches for aerators.
iv. 2-inch red LED low oxygen indicator:
(1) Visible from the truck’s rearview mirror.
(2) Alerts the driver when tank pressure is low.
3.2.6. ACCESSORIES
a. Oxygen bottle holder
i. Style: Double bottle.
ii. Orientation: Horizontal.
iii. Placement: Mounted to front of tank.
b. Support tabs: Two on the driver and two on the passenger side towards the corners (four total).
c. Grab rails
i. Top: Installed around the tank’s top perimeter 4 inches height. Leave a gap in front of the lid opening.
ii. Rear: Installed on either side of discharge. Rail to extend the full height of tank.
d. Sight gauge with protection wings
i. Quantity: One gauge.
ii. Placement: Rear exterior wall of tank.
e. Picking eyes: 0.375-inch thickness, one installed on all four corners on the tank’s top (four total).
f. Lifting: Forklift tubes.
| 5430-BS-0228448-1.pdf |
| Table of Contents |
| 1.0 Scope |
| 2.0 Applicable Laws and Standards |
| 2.1 Laws, Regulations, Policies |
| 2.2 Standards |
| 3.0 Technical Requirements |
| 3.1 250 Gallon Tank, One Compartment (Mad River) |
| 3.1.1. Tank Construction |
| 3.1.2. Access Lid |
| 3.1.3. Drain/Discharge |
| 3.1.4. Oxygen Delivery and Aeration |
| 3.1.5. Electrical System |
| 3.2 400 Gallon Tank, One Compartment (Iron Gate Hatchery) |
| 3.2.1. Tank Construction |
| 3.2.2. Access Lid |
| 3.2.3. Drain/Discharge |
| 3.2.4. Oxygen Delivery and Aeration |
| 3.2.5. Electrical System |
| 3.2.6. Accessories |
5430-BS-0228448-2.pdf
File details come from the government source that posted it. Updated .