Att 2 TRSSF BCOES Specs NOT FOR CONSTRUCTION.pdf
PDF 16 MB Posted
- Attached to
- Construction of Training Support Squadron Facility (TRSS-F) at Langley AFB, Hampton, VA Federal contract opportunity
- Solicitation number
- W9123623R2002
About this file
This notice provides details for a construction project to build a Training Squadron Support Facility at Langley Air Force Base in Hampton, Virginia. The U.S. Army Corps of Engineers-Norfolk District intends to issue a Request for Proposal for a firm-fixed-price contract to construct an eight-bay facility to support additional F-22A flight crews. The facility will include classrooms, simulators, staff space, restrooms, briefing rooms, and building systems. The project scope also encompasses utilities, site work, security features, and supporting facilities. The contract completion date will be 1064 calendar days after notice to proceed. Prospective offerors should monitor sam.gov where the RFP will be posted on or about February 17, 2023. Offerors must be registered in SAM and remain so through final payment. Preliminary plans and specifications are attached for advance review.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Att 1-2of3 TRSSF BCOES Drawings NOT FOR CONSTRUCTION.pdf | ||
| Att 1-3of3 TRSSF BCOES Drawings NOT FOR CONSTRUCTION.pdf | ||
| Att 1-1of3 TRSSF BCOES Drawings NOT FOR CONSTRUCTION.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Training Support Squadron
Facility (TRSS-F)
Specifications
BCOES Design Submittal
January 19, 2023
Solicitation Number: F22 Formal Training Unit (FTU)
Construction Contract Number : Joint Base Langley-Eustis (JBLE)
W91236-20-F-0042 3012011031TRSSF
PROJECT TABLE OF CONTENTS Page 1
PROJECT TABLE OF CONTENTS
DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS
00 01 15 02/11 LIST OF DRAWINGS
Appendix: List of Drawings
00 22 13.00 20 02/14 SUPPLEMENTARY INSTRUCTIONS TO OFFERORS
DIVISION 01 - GENERAL REQUIREMENTS
01 11 00 03/20 SPECIAL CONDITIONS FOR MILCON
PROJECTS
01 14 00 11/11 WORK RESTRICTIONS
01 30 00 08/15 ADMINISTRATIVE REQUIREMENTS
01 32 01.00 10 02/15 PROJECT SCHEDULE
01 33 00 08/18 SUBMITTAL PROCEDURES
Appendix: Submittal Register
01 33 29 02/17 SUSTAINABILITY REPORTING
Appendix: Sustainability Scorecard
01 35 26 11/15 GOVERNMENTAL SAFETY REQUIREMENTS
01 42 00 02/19 SOURCES FOR REFERENCE PUBLICATIONS
01 45 00.00 10 11/16 QUALITY CONTROL
00.15
10 11/16
02/20
RESIDENT MANAGEMENT SYSTEM CONTRACTOR
MODE (RMS CM)
SPECIAL INSPECTIONS
Appendix A: Schedule of Special Inspections Appendix B: Statement of Special Inspections
13.00
05/18
07/06
TEMPORARY CONSTRUCTION FACILITIES AND
CONTROLS
EROSION AND SEDIMENT CONTROL
01 57 19 11/15 TEMPORARY ENVIRONMENTAL CONTROLS
Appendix: JBLE-Langley Environmental Special Conditions
01 58 00 08/19 PROJECT IDENTIFICATION
02/19
05/19
CONSTRUCTION WASTE MANAGEMENT AND
DISPOSAL
CLOSEOUT SUBMITTALS
01 78 23 08/15 OPERATION AND MAINTENANCE DATA
01 78 24.00 10 05/18 FACILITY DATA REQUIREMENTS
01 91 00.15 10 05/19 TOTAL BUILDING COMMISSIONING
Appendix: Construction Phase
Commissioning Plan
DIVISION 02 - EXISTING CONDITIONS
02 41 00
05/10
DEMOLITION
DIVISION 03 - CONCRETE
03 30 00
02/19
CAST-IN-PLACE CONCRETE
DIVISION 04 - MASONRY
04 20 00
11/15
UNIT MASONRY
DIVISION 05 - METALS
20.00
27 02/21
08/18
POST-INSTALLED CONCRETE AND MASONRY
ANCHORS
STRUCTURAL STEEL
PROJECT TABLE OF CONTENTS Page 2
05 21 00 05/15 STEEL JOIST FRAMING
05 30 00 05/15 STEEL DECKS
05 40 00 05/15 COLD-FORMED METAL FRAMING
05 50 13 05/17 MISCELLANEOUS METAL FABRICATIONS
05 50 14 08/18 STRUCTURAL METAL FABRICATIONS
05 51 00 02/17 METAL STAIRS
05 51 33 02/16 METAL LADDERS
05 52 00 02/18 METAL RAILINGS
DIVISION 06 - WOOD, PLASTICS, AND COMPOSITES
06 10 00 08/16 ROUGH CARPENTRY
06 41 16.00 10 08/10 PLASTIC-LAMINATE-CLAD ARCHITECTURAL
CABINETS AND WALL CLADDING
06 61 16 08/10 SOLID SURFACING FABRICATIONS
DIVISION 07 - THERMAL AND MOISTURE PROTECTION
07 05 23 08/19 PRESSURE TESTING AN AIR BARRIER SYSTEM
FOR AIR TIGHTNESS
07 21 13 02/16 BOARD AND BLOCK INSULATION
07 21 16 11/11 MINERAL FIBER BLANKET INSULATION
07 22 00 02/16 ROOF AND DECK INSULATION
07 27 10.00 10 08/19 BUILDING AIR BARRIER SYSTEM
07 27 36 05/17 SPRAY FOAM AIR BARRIERS
07 41 13 05/11, CHG 4: 02/21 METAL ROOF PANELS
07 52 00 05/12 MODIFIED BITUMINOUS MEMBRANE ROOFING
07 60 00 05/17 FLASHING AND SHEET METAL
07 84 00 05/10 FIRESTOPPING
07 92 00 08/16 JOINT SEALANTS
DIVISION 08 - OPENINGS
08 11 13 02/10 STEEL DOORS AND FRAMES
08 14 00 08/16 WOOD DOORS
08 31 00 05/17 ACCESS DOORS AND PANELS
08 34 73 11/19 SOUND CONTROL DOOR ASSEMBLIES
08 36 19 11/11 VERTICAL LIFT DOORS
08 41 13 08/18 ALUMINUM-FRAMED ENTRANCES AND
STOREFRONTS
08 44 00 05/19 CURTAIN WALL AND GLAZED ASSEMBLIES
08 56 19 02/16 PASS WINDOWS
08 71 00 02/16 DOOR HARDWARE
Appendix: Hardware List
08 81 00 05/19 GLAZING
08 91 00 05/11 METAL WALL LOUVERS
DIVISION 09 - FINISHES
09 22 00 02/10 SUPPORTS FOR PLASTER AND GYPSUM BOARD
09 29 00 08/16 GYPSUM BOARD
09 30 10 08/17 CERAMIC, QUARRY, AND GLASS TILING
09 51 00 08/17 ACOUSTICAL CEILINGS
09 62 38 08/17 STATIC-CONTROL FLOORING
09 65 00 08/10 RESILIENT FLOORING
09 66 23 08/16 RESINOUS MATRIX TERRAZZO FLOORING
09 67 23.13 11/19 STANDARD RESINOUS FLOORING
09 68 00 11/17 CARPETING
09 69 13 11/15 RIGID GRID ACCESS FLOORING
09 70 00 09/21 PLASTIC LAMINATE CLAD PANEL WALL SYSTEM
09 71 00 09/21 WALL FINISHES
09 72 00 08/17, CHG 1: 08/18 WALLCOVERINGS
PROJECT TABLE OF CONTENTS Page 3
09 84 20 08/16 ACOUSTICAL WALL PANELS
09 90 00 05/11 PAINTS AND COATINGS
DIVISION 10 - SPECIALTIES
10 14 00.20 08/17 INTERIOR SIGNAGE
10 21 13 08/17 TOILET COMPARTMENTS
10 22 39 08/17 FOLDING PANEL PARTITIONS
10 26 00 08/17 WALL AND DOOR PROTECTION
10 28 13 08/17 TOILET ACCESSORIES
10 44 16 11/19 FIRE EXTINGUISHERS
10 51 13 05/11 METAL LOCKERS
10 56 13 04/06 STEEL SHELVING
DIVISION 12 - FURNISHINGS
12 24 13 08/17 ROLLER WINDOW SHADES
12 48 13 08/17 ENTRANCE FLOOR MATS AND FRAMES
12 50 00.13 10 08/17 FURNITURE AND FURNITURE INSTALLATION
12 61 13 08/17 UPHOLSTERED AUDIENCE SEATING
12 93 00 08/17 SITE FURNISHINGS
DIVISION 14 - CONVEYING EQUIPMENT
14 24 23 05/16 HYDRAULIC PASSENGER ELEVATORS
DIVISION 21 - FIRE SUPPRESSION
21 13 13.00 10 05/09 WET PIPE SPRINKLER SYSTEM, FIRE
PROTECTION
DIVISION 22 - PLUMBING
22 00 00 11/15 PLUMBING, GENERAL PURPOSE
DIVISION 23 - HEATING, VENTILATING, AND AIR CONDITIONING (HVAC)
23 05 15 02/14 COMMON PIPING FOR HVAC
23 05 48.00 40 08/15 VIBRATION AND SEISMIC CONTROLS FOR
23 05 93
HVAC PIPING AND EQUIPMENT
TESTING, ADJUSTING, AND BALANCING FOR
23 07 00
02/13
HVAC
THERMAL INSULATION FOR MECHANICAL
23 09 00
SYSTEMS
INSTRUMENTATION AND CONTROL FOR HVAC
23 09 13
23 09 23
11/15 INSTRUMENTATION AND CONTROL DEVICES
FOR HVAC
DIRECT DIGITAL CONTROL FOR HVAC AND
23 11 20
05/20
OTHER BUILDING CONTROL SYSTEMS
FACILITY GAS PIPING
23 21 13.00 20 04/06 LOW TEMPERATURE WATER (LTW) HEATING
23 21 23
08/17
SYSTEM
HYDRONIC PUMPS
23 23 00 10/07 REFRIGERANT PIPING
23 25 00 11/08 CHEMICAL TREATMENT OF WATER FOR
23 30 00
05/20
MECHANICAL SYSTEMS
HVAC AIR DISTRIBUTION
23 52 00 04/08 HEATING BOILERS
23 64 10 11/16 WATER CHILLERS, VAPOR COMPRESSION TYPE
10 11 00 08/17 VISUAL DISPLAY UNITS
10 14 00.10 08/17 EXTERIOR SIGNAGE
PROJECT TABLE OF CONTENTS Page 4
23 64 26 08/09 CHILLED WATER PIPING SYSTEMS
23 81 00 05/18 DECENTRALIZED UNITARY HVAC EQUIPMENT
DIVISION 25 - INTEGRATED AUTOMATION
25 05 11.01 11/17 CYBERSECURITY FOR FACILITY-RELATED
HVAC CONTROL SYSTEMS
25 05 11.02 11/17 CYBERSECURITY FOR FACILITY-RELATED
FIRE ALARM CONTROL SYSTEMS
25 08 10 05/21 UTILITY MONITORING AND CONTROL SYSTEM
TESTING
25 10 10 02/19, CHG 1: 05/21 UTILITY MONITORING AND CONTROL SYSTEM
(UMCS) FRONT END AND INTEGRATION
DIVISION 26 - ELECTRICAL
26 08 00 08/08 APPARATUS INSPECTION AND TESTING
26 20 00 08/19 INTERIOR DISTRIBUTION SYSTEM
26 24 13 05/15 SWITCHBOARDS
Appendix: AMRS Meter Specifications
26 29 23 02/20 ADJUSTABLE SPEED DRIVE (ASD) SYSTEMS
UNDER 600 VOLTS
26 33 53 05/19 STATIC UNINTERRUPTIBLE POWER SUPPLY
(UPS)
26 41 00 11/13 LIGHTNING PROTECTION SYSTEM
26 42 14.00 10 08/09 CATHODIC PROTECTION SYSTEM
(SACRIFICIAL ANODE)
26 51 00 05/20 INTERIOR LIGHTING
26 56 00 05/20 EXTERIOR LIGHTING
DIVISION 27 - COMMUNICATIONS
27 05 13.43 05/20 TELEVISION DISTRIBUTION SYSTEM
27 10 00 08/11 BUILDING TELECOMMUNICATIONS CABLING
SYSTEM
Appendix: JBLE-Langley Telecommunication Building Cabling Systems
27 40 10 10/20 AUDIO-VISUAL GENERAL
27 40 90.01 11/20 AUDIO-VISUAL PERFORMANCE VERIFICATION
27 41 05 11/20 AUDIO-VISUAL EQUIPMENT ENCLOSURES AND
TECHNICAL FURNITURE
27 41 06 11/20 AUDIO-VISUAL POWER DISTRIBUTION AND
MANAGEMENT EQUIPMENT
27 41 10 11/20 MICROPHONES, CONFERENCING SYSTEM, AND
AUDIO SOURCE EQUIPMENT
27 41 11 11/20 AUTOMATED MIXING, PROCESSING AND
AMPLIFICATION EQUIPMENT
27 41 13 11/20 REINFORCEMENT AND PROGRAM AUDIO
LOUDSPEAKERS
27 41 23 11/20 VIDEO DISPLAY EQUIPMENT
27 41 26 11/20 PROJECTION SCREENS
27 41 31 11/20 AUDIO-VISUAL CONTROL SYSTEMS AND
PROGRAMMING
27 41 32 11/20 AUDIO-VISUAL NETWORK EQUIPMENT
27 41 40 11/20 AUDIO-VISUAL CABLING AND CONNECTORS.
27 51 16 05/20 PUBLIC ADDRESS SYSTEMS
DIVISION 28 - ELECTRONIC SAFETY AND SECURITY
28 31 76 08/11 INTERIOR FIRE ALARM AND MASS
NOTIFICATION SYSTEM
PROJECT TABLE OF CONTENTS Page 5
DIVISION 31 - EARTHWORK
31 00 00 08/08 EARTHWORK
31 05 19.13 02/21 GEOTEXTILES FOR EARTHWORK
31 11 00 11/18 CLEARING AND GRUBBING
DIVISION 32 - EXTERIOR IMPROVEMENTS
32 01 19.61 11/19 SEALING OF JOINTS IN RIGID PAVEMENT
32 05 33 08/17 LANDSCAPE ESTABLISHMENT
32 11 23 08/17 AGGREGATE BASE COURSES
32 12 13 05/17 BITUMINOUS TACK COAT
32 12 16 08/09 HOT-MIX ASPHALT (HMA) FOR ROADS
32 13 13.06 05/20 PORTLAND CEMENT CONCRETE PAVEMENT FOR
SITE FACILITIES INCLUDING SIGNAGE
32 16 19 05/18 CONCRETE CURBS, GUTTERS AND SIDEWALKS
32 31 13.53 02/20 ORNAMENTAL FENCE AND GATES
32 92 23 04/06 SODDING
32 93 00 08/17 EXTERIOR PLANTS
DIVISION 33 - UTILITIES
33 11 00 02/18 WATER UTILITY DISTRIBUTION PIPING
33 30 00 05/18 SANITARY SEWERAGE
33 32 16 11/19 PACKAGED UTILITY WASTEWATER PUMPING
STATIONS
33 40 00 02/10 STORM DRAINAGE UTILITIES
33 71 02 02/15 UNDERGROUND ELECTRICAL DISTRIBUTION
33 82 00 04/06 TELECOMMUNICATIONS OUTSIDE PLANT (OSP)
-- End of Project Table of Contents --
DOCUMENT 00 01 15
LIST OF DRAWINGS
02/11
PART 1 GENERAL
1.1 SUMMARY
This section lists the drawings for the project pursuant to contract clause "DFARS 252.236-7001, Contract Drawings, Maps and Specifications."
1.2 CONTRACT DRAWINGS
See List of Drawings attached to this specification section.
1.3 SUPPLEMENTARY DATA
These supplementary Data may not be a part of the contract but are included for information.
1.3.1 Boring Logs
The Government does not guarantee that borings indicate actual conditions, except for the exact locations and the time that they were made.
Subsurface data, not specified or indicated, have been obtained by the Government at this station.
1.3.2 Subsurface Data
The soils report is included as part of the solicitation.
00 01 15 LIST DRAWINGS APPENDIX
-- End of Document --
DOCUMENT 00 01 15 Page 1
COORD_SHEET INDEX FOR EXCEL
SHEET NUMBER SHEET NAME
00. GENERAL
G-001 COVER SHEET
G-002 SHEET INDEX
G-003 BUILDING AND LIFE SAFETY CODE EVALUATION
G-004 OCCUPANT LOAD ROOM SCHEDULES
GS101 CODE COMPLIANCE SITE PLAN
G-101 FIRST FLOOR LIFE SAFETY PLAN - OVERALL
G-102 SECOND FLOOR LIFE SAFETY PLAN - OVERALL
00. GENERAL: 7
02. SURVEY AND MAPPING
V-001 LEGENDS AND NOTES
VF100 OVERALL EXISTING CONDITIONS
VF101 EXISTING CONDITIONS
VF102 EXISTING CONDITIONS
02. SURVEY AND MAPPING: 4
04.CIVIL
C-001 LEGEND AND GENERAL NOTES
C-002 CONSTRUCTION ACCESS PLAN
C-003 EROSION AND SEDIMENT CONTROL PLAN INITIAL
C-004 EROSION AND SEDIMENT CONTROL PLAN FINAL
CD001 DEMOLITION LEGEND & NOTES
CD100 EXISTING CONDITIONS - OVERALL
CD101 EXISTING CONDITIONS AND DEMOLITION PLAN
CD102 EXISTING CONDITIONS AND DEMOLITION PLAN
CD103 EXISTING CONDITIONS, EROSION CONTROL AND DEMOLITION PLAN - OFFSITE
CS001 SITE LAYOUT LEGEND & CONTROL POINTS
CS101 SITE LAYOUT PLAN
CS102 SITE LAYOUT PLAN
CS103 SITE LAYOUT PLAN - OFFSITE
CS104 OVERALL JOINTING PLAN
CS401 ENLARGED JOINTING PLANS
CG001 GRADING LEGEND, STORM SCHEDULES & NOTES
CG101 GRADING PLAN
CG102 GRADING PLAN
CG103 GRADING PLAN - OFFSITE
CG201 STORM SEWER PROFILES
CG202 STORM SEWER PROFILES
CG203 STORM SEWER PROFILES
CG204 STORM SEWER PROFILES
CG205 STORM SEWER PROFILES
CG700 POST DEVELOPMENT DRAINAGE AREAS
CG701 STORMWATER MANAGEMENT CALCULATIONS
CG702 STORMWATER MANAGEMENT CALCULATIONS
CU001 UTILITY LEGEND, CONTROL POINTS & SCHEDULES
CU101 UTILITY PLAN
CU102 UTILITY PLAN
CU201 UTILITY PROFILES
CU202 UTILITY PROFILES
CU203 UTILITY PROFILES
C-501 EROSION AND SEDIMENT CONTROL DETAILS AND NOTES
RoseborS Text Box Appendix to 00 01 15 - List of Drawings
C-502 EROSION AND SEDIMENT CONTROL DETAILS AND NOTES
C-503 EROSION AND SEDIMENT CONTROL DETAILS AND NOTES
C-504 EROSION AND SEDIMENT CONTROL DETAILS AND NOTES
C-505 EROSION AND SEDIMENT CONTROL DETAILS
C-506 DETAILS
C-507 DETAILS
C-508 DETAILS
C-509 DETAILS
C-510 DETAILS
C-511 DETAILS
C-512 DETAILS
C-513 DETAILS
C-514 DETAILS
C-515 DETAILS
C-516 DETAILS
C-517 DETAILS
C-518 DETAILS
C-519 DETAILS
C-520 DETAILS
C-521 DETAILS
04.CIVIL: 54
05. LANDSCAPE
L-101 LANDSCAPE PLAN
L-102 LANDSCAPE PLAN
L-103 LANDSCAPE PLAN
L-104 LANDSCAPE PLAN
L-105 LANDSCAPE PLAN
L-501 LANDSCAPE DETAILS
05. LANDSCAPE: 6
06. STRUCTURAL
S-001 GENERAL STRUCTURAL NOTES - 1
S-002 GENERAL STRUCTURAL NOTES - 2
S-003 GENERAL STRUCTURAL NOTES - 3
S-004 GENERAL STRUCTURAL NOTES - 4
S-005 GENERAL STRUCTURAL NOTES - 5
S-101 FOUNDATION PLAN - OVERALL
S101A FOUNDATION PLAN - AREA A
S101B FOUNDATION PLAN - AREA B
S101C FOUNDATION PLAN - AREA C
S101D FOUNDATION PLAN - AREA D
S-102 SECOND FLOOR FRAMING PLAN - OVERALL
S102A SECOND FLOOR FRAMING PLAN - AREA A
S102B SECOND FLOOR FRAMING PLAN - AREA B
S102C SECOND FLOOR FRAMING PLAN - AREA C
S-103 ROOF FRAMING PLAN - OVERALL
S103A ROOF FRAMING PLAN - AREA A
S103B ROOF FRAMING PLAN - AREA B
S103C ROOF FRAMING PLAN - AREA C
S103D ROOF FRAMING PLAN - AREA D
S-201 LATERAL RESISTING SYSTEM ELEVATIONS - 1
S-202 LATERAL RESISTING SYSTEM ELEVATIONS - 2
S-203 LATERAL RESISTING SYSTEM ELEVATIONS - 3
S-204 LATERAL RESISTING SYSTEM ELEVATIONS - 4
S-301 FOUNDATION SECTIONS - 1
S-302 FOUNDATION SECTIONS - 2
S-303 FOUNDATION SECTIONS - 3
S-321 SECOND FLOOR FRAMING SECTIONS - 1
S-322 SECOND FLOOR FRAMING SECTIONS - 2
S-323 SECOND FLOOR FRAMING SECTIONS - 3
S-331 ROOF FRAMING SECTIONS - 1
S-332 ROOF FRAMING SECTIONS - 2
S-333 ROOF FRAMING SECTIONS - 3
S-334 ROOF FRAMING SECTIONS - 4
S-401 ENLARGED FRAMING PLANS
S-402 ENLARGED STAIR PLAN AND SECTIONS
S-403 ENLARGED CANOPY PLANS AND SECTIONS
S-404 ENLARGED MECH UNIT PLAN AND SECTIONS
S-405 ENLARGED CMU STAIR TOWER PLANS
S-406 ENLARGED BREAK AREA CANOPY PLAN AND SECTIONS
S-407 ENLARGED SITE SLAB PLANS AND SECTIONS
S-501 FOUNDATION DETAILS
S-502 MASONRY DETAILS
S-511 STEEL DETAILS - 1
S-512 STEEL DETAILS - 2
S-513 STEEL DETAILS - 3
S-601 SCHEDULES - 1
S-602 SCHEDULES - 2
S-603 SCHEDULES - 3
S-901 3D ISOMETRICS
06. STRUCTURAL: 49
07. ARCHITECTURAL
A-001 GENERAL NOTES
A-002 PARTITION TYPES
A-003 ACOUSTIC PENETRATION DETAILS
AS101 ARCHITECTURAL SITE PLAN
AS401 ENLARGED SITE PLANS
AS402 SITE DETAILS
A-101 FIRST FLOOR PLAN - OVERALL
A101A FIRST FLOOR PLAN - AREA A
A101B FIRST FLOOR PLAN - AREA B
A101C FIRST FLOOR PLAN - AREA C
A101D FIRST FLOOR PLAN - AREA D
A-102 SECOND FLOOR PLAN - OVERALL
A102A SECOND FLOOR PLAN - AREA A
A102B SECOND FLOOR PLAN - AREA B
A102C SECOND FLOOR PLAN - AREA C
A-103 ROOF PLAN - OVERALL
A103A ROOF PLAN - AREA A
A-104 FIRST FLOOR REFLECTED CEILING PLAN - OVERALL
A104A FIRST FLOOR REFLECTED CEILING PLAN - AREA A
A104B FIRST FLOOR REFLECTED CEILING PLAN - AREA B
A104C FIRST FLOOR REFLECTED CEILING PLAN - AREA C
A104D FIRST FLOOR REFLECTED CEILING PLAN - AREA D
A-105 SECOND FLOOR REFLECTED CEILING PLAN - OVERALL
A105A SECOND FLOOR REFLECTED CEILING PLAN - AREA A
A105B SECOND FLOOR REFLECTED CEILING PLAN - AREA B
A105C SECOND FLOOR REFLECTED CEILING PLAN - AREA C
A-141 FIRST FLOOR AIR BARRIER PLAN
A-142 SECOND FLOOR AIR BARRIER PLAN
A-143 AIR BARRIER SECTIONS
A-201 EXTERIOR BUILDING ELEVATIONS
A-202 EXTERIOR BUILDING ELEVATIONS
A-203 EXTERIOR BUILDING ELEVATIONS
A-204 EXTERIOR BUILDING ELEVATIONS
A-205 EXTERIOR BUILDING ELEVATIONS
A-301 BUILDING SECTIONS
A-302 BUILDING SECTIONS
A-303 BUILDING SECTIONS
A-304 BUILDING SECTIONS
A-305 BUILDING SECTIONS
A-306 BUILDING SECTIONS
A-307 BUILDING SECTIONS
A-308 BUILDING SECTIONS
A-311 WALL SECTIONS
A-312 WALL SECTIONS
A-313 WALL SECTIONS
A-314 WALL SECTIONS
A-315 WALL SECTIONS
A-316 WALL SECTIONS
A-317 WALL SECTIONS
A-318 WALL SECTIONS
A-319 WALL SECTIONS
A-401 ENLARGED PLANS AND INTERIOR ELEVATIONS
A-402 ENLARGED PLANS AND INTERIOR ELEVATIONS
A-403 ENLARGED PLANS AND INTERIOR ELEVATIONS
A-404 ENLARGED PLANS AND INTERIOR ELEVATIONS
A-405 ENLARGED PLAN ROOM 221
A-406 ENLARGED RCP ROOM 221
A-407 INTERIOR ELEVATIONS AND SECTION ROOM 221
A-408 MISCELLANEOUS CASEWORK ELEVATIONS AND SECTIONS
A-409 ENLARGED LOBBY PLAN AND INTERIOR ELEVATIONS
A-410 ENLARGED CANOPY PLANS, SECTIONS AND DETAILS
A-411 EXTERIOR WALL DETAILS
A-421 ABA MOUNTING HEIGHTS
A-451 STAIR 163 PLANS AND SECTION
A-452 STAIR 138 AND 152 PLANS AND SECTION
A-453 STAIR 163 AND 138 DETAILS
A-454 MEZZANINE STAIR PLAN, SECTION AND DETAILS
A-455 STAIR 107 DETAILS
A-456 STAIR 107 DETAILS
A-461 VERTICAL CIRCULATION - ELEVATOR PLANS, SECTIONS & DETAILS
A-501 CEILING AND RAISED ACCESS FLOORING DETAILS
A-521 LIGHT WEIGHT CAST STONE ROOF DETAILS
A-522 ROOF DETAILS
A-523 WALL SECTION DETAILS
A-524 WALL SECTION DETAILS
A-525 MISCELANEOUS DETAILS
A-531 VERTICAL RETRACTABLE PARTITION DETAILS
A-601 DOOR SCHEDULE
A-602 DOOR HEAD, JAMB AND SILL DETAILS
A-603 INTERIOR WINDOW AND STOREFRONT TYPES
07. ARCHITECTURAL: 80
08. INTERIORS
I101A FIRST FLOOR INTERIOR FINISH PLAN - AREA A
I101B FIRST FLOOR INTERIOR FINISH PLAN - AREA B
I101C FIRST FLOOR INTERIOR FINISH PLAN - AREA C
I101D FIRST FLOOR INTERIOR FINISH PLAN - AREA D
I102A SECOND FLOOR INTERIOR FINISH PLAN - AREA A
I102B SECOND FLOOR INTERIOR FINISH PLAN - AREA B
I102C SECOND FLOOR INTERIOR FINISH PLAN - AREA C
I-131 WALL PATTERN PLANS AND DETAILS
I-132 INTERIOR DETAILS
I-133 INTERIOR DETAILS
I-601 INTERIOR FINISH LEGEND AND DETAILS
I-602 INTERIOR ROOM FINISH SCHEDULE
IG101A FIRST FLOOR SIGNAGE PLAN - AREA A
IG101B FIRST FLOOR SIGNAGE PLAN - AREA B
IG101C FIRST FLOOR SIGNAGE PLAN - AREA C
IG101D FIRST FLOOR SIGNAGE PLAN - AREA D
IG102A SECOND FLOOR SIGNAGE PLAN - AREA A
IG102B SECOND FLOOR SIGNAGE PLAN - AREA B
IG102C SECOND FLOOR SIGNAGE PLAN - AREA C
IG401 SIGNAGE ELEVATIONS AND DETAILS
IG601 SIGNAGE SCHEDULE
IF100 GFGI FURNITURE SCHEDULE AND NOTES
IF101 FIRST FLOOR INTERIOR FURNITURE PLAN - OVERALL
IF101A FIRST FLOOR INTERIOR FURNITURE PLAN - AREA A
IF101B FIRST FLOOR INTERIOR FURNITURE PLAN - AREA B
IF101C FIRST FLOOR INTERIOR FURNITURE PLAN - AREA C
IF101D FIRST FLOOR INTERIOR FURNITURE PLAN - AREA D
IF102 SECOND FLOOR INTERIOR FURNITURE PLAN - OVERALL
IF102A SECOND FLOOR INTERIOR FURNITURE PLAN - AREA A
IF102B SECOND FLOOR INTERIOR FURNITURE PLAN - AREA B
IF102C SECOND FLOOR INTERIOR FURNITURE PLAN - AREA C
IF501 VISUAL DISPLAY DETAILS
IF601 FURNITURE SCHEDULE AND NOTES
IF602 FURNITURE SCHEDULE AND NOTES
08. INTERIORS: 34
10. FIRE PROTECTION
FA001 FIRE ALARM NOTES, LEGENDS, DETAILS & OPERATIONS MATRIX
FA002 FIRE ALARM OPERATIONS MATRIX (RFMCP)
FA003 FIRE ALARM / MASS NOTIFICATION SYSTEM RISER DIAGRAM
FA101 FIRST FLOOR FIRE ALARM PLAN - OVERALL
FA101A FIRST FLOOR FIRE ALARM PLAN - AREA A
FA101B FIRST FLOOR FIRE ALARM PLAN - AREA B
FA101C FIRST FLOOR FIRE ALARM PLAN - AREA C
FA101D FIRST FLOOR FIRE ALARM PLAN - AREA D
FA102 SECOND FLOOR FIRE ALARM PLAN - OVERALL
FA102A SECOND FLOOR FIRE ALARM PLAN - AREA A
FA102B SECOND FLOOR FIRE ALARM PLAN - AREA B
FA102C SECOND FLOOR FIRE ALARM PLAN - AREA C
FX001 FIRE SPRINKLER NOTES, LEGEND AND DETAILS
FX101 FIRST FLOOR FIRE SPRINKLER PLAN - OVERALL
FX101A FIRST FLOOR FIRE SPRINKLER PLAN - AREA A
FX101B FIRST FLOOR FIRE SPRINKLER PLAN - AREA B
FX101C FIRST FLOOR FIRE SPRINKLER PLAN - AREA C
FX101D FIRST FLOOR FIRE SPRINKLER PLAN - AREA D
FX102 SECOND FLOOR FIRE SPRINKLER PLAN - OVERALL
FX102A SECOND FLOOR FIRE SPRINKLER PLAN - AREA A
FX102B SECOND FLOOR FIRE SPRINKLER PLAN - AREA B
FX102C SECOND FLOOR FIRE SPRINKLER PLAN - AREA C
10. FIRE PROTECTION: 22
11. PLUMBING
P-001 PLUMBING GENERAL NOTES, SYMBOLS AND ABBREVIATIONS
P-101 FIRST FLOOR PRESSURE PIPING PLAN - OVERALL
P101A FIRST FLOOR PRESSURE PIPING PLAN - AREA A
P101B FIRST FLOOR PRESSURE PIPING PLAN - AREA B
P101C FIRST FLOOR PRESSURE PIPING PLAN - AREA C
P101D FIRST FLOOR PRESSURE PIPING PLAN - AREA D
P-102 SECOND FLOOR PRESSURE PIPING PLAN - OVERALL
P102B SECOND FLOOR PRESSURE PIPING PLAN - AREA B
P102C SECOND FLOOR PRESSURE PIPING PLAN - AREA C
P-111 FIRST FLOOR DRAIN WASTE VENT PIPING PLAN - OVERALL
P111A FIRST FLOOR DRAIN WASTE VENT PIPING PLAN - AREA A
P111B FIRST FLOOR DRAIN WASTE VENT PIPING PLAN - AREA B
P111C FIRST FLOOR DRAIN WASTE VENT PIPING PLAN - AREA C
P111D FIRST FLOOR DRAIN WASTE VENT PIPING PLAN - AREA D
P-112 SECOND FLOOR DRAIN WASTE VENT PIPING PLAN - OVERALL
P112A SECOND FLOOR DRAIN WASTE VENT PIPING PLAN - AREA A
P112B SECOND FLOOR DRAIN WASTE VENT PIPING PLAN - AREA B
P112C SECOND FLOOR DRAIN WASTE VENT PIPING PLAN - AREA C
P-121 ROOF DRAIN WASTE VENT PIPING PLAN - OVERALL
P121A ROOF DRAIN WASTE VENT PIPING PLAN - AREA A
P121B ROOF DRAIN WASTE VENT PIPING PLAN - AREA B
P121C ROOF DRAIN WASTE VENT PIPING PLAN - AREA C
P121D ROOF DRAIN WASTE VENT PIPING PLAN - AREA D
P-401 PLUMBING ENLARGED PLANS
P-402 PLUMBING ENLARGED PLANS
P-403 PLUMBING ENLARGED PLANS
P-501 PLUMBING DETAILS
P-502 PLUMBING DETAILS
P-701 PLUMBING SCHEDULES
P-901 PRESSURE PIPING RISER DIAGRAM - AREA A AND B
P-902 PRESSURE PIPING RISER DIAGRAM - AREA C AND D
P-903 ENLARGED PRESSURE PIPING RISER DIAGRAMS
P-904 DWV RISER DIAGRAM- AREA A, B, AND C
P-905 ENLARGED DWV RISER DIAGRAMS
11. PLUMBING: 34
13. MECHANICAL
M-001 MECHANICAL GENERAL NOTES, SYMBOLS AND ABBREVIATIONS
MD101 HVAC DEMOLITION PLAN GEO WELLS
MS100 MECHANICAL SITE PLAN
MS101 MECHANICAL YARD PLAN
M-101 FIRST FLOOR HVAC PLAN - OVERALL
M101A FIRST FLOOR HVAC PLAN - AREA A
M101B FIRST FLOOR HVAC PLAN - AREA B
M101C FIRST FLOOR HVAC PLAN - AREA C
M101D FIRST FLOOR HVAC PLAN - AREA D
M111A FIRST FLOOR AIRFLOW PLAN - AREA A
M111B FIRST FLOOR AIRFLOW PLAN - AREA B
M111C FIRST FLOOR AIRFLOW PLAN - AREA C
M111D FIRST FLOOR AIRFLOW PLAN - AREA D
M-102 SECOND FLOOR HVAC PLAN - OVERALL
M102A SECOND FLOOR HVAC PLAN - AREA A
M102B SECOND FLOOR HVAC PLAN - AREA B
M102C SECOND FLOOR HVAC PLAN - AREA C
M112A SECOND FLOOR AIRFLOW PLAN - AREA A
M112B SECOND FLOOR AIRFLOW PLAN - AREA B
M112C SECOND FLOOR AIRFLOW PLAN - AREA C
MP101 FIRST FLOOR HVAC PIPING PLAN - OVERALL
MP101A FIRST FLOOR HVAC PIPING PLAN - AREA A
MP101B FIRST FLOOR HVAC PIPING PLAN - AREA B
MP101C FIRST FLOOR HVAC PIPING PLAN - AREA C
MP101D FIRST FLOOR HVAC PIPING PLAN - AREA D
MP102 SECOND FLOOR HVAC PIPING PLAN - OVERALL
MP102A SECOND FLOOR HVAC PIPING PLAN - AREA A
MP102B SECOND FLOOR HVAC PIPING PLAN - AREA B
MP102C SECOND FLOOR HVAC PIPING PLAN - AREA C
M-103 ROOF HVAC & PIPING PLAN
M-401 HVAC ENLARGED PLANS
M-402 MECHANICAL SECTIONS
M-403 MECHANICAL SECTIONS
M-404 MECHANICAL SECTIONS
M-501 MECHANICAL DETAILS
M-502 MECHANICAL DETAILS
M-503 MECHANICAL DETAILS
M-601 MECHANICAL SCHEDULES
M-602 MECHANICAL SCHEDULES
M-603 MECHANICAL SCHEDULES
M-801 MECHANICAL CONTROLS SCHEMATICS
M-802 MECHANICAL CONTROLS SCHEMATICS
M-803 MECHANICAL CONTROLS SCHEMATICS
M-804 MECHANICAL CONTROLS SCHEMATICS
M-805 MECHANICAL CONTROLS SCHEMATICS
13. MECHANICAL: 45
14. ELECTRICAL
E-001 ELECTRICAL LEGEND, GENERAL NOTES AND ABBREVIATIONS
ES100 ELECTRICAL SITE KEY PLAN
ED101 ELECTRICAL SITE DEMOLITION PLAN
ED102 ELECTRICAL SITE DEMOLITION PLAN
ED103 ELECTRICAL SITE DEMOLITION PLAN
ES101 ELECTRICAL SITE PLAN
ES102 ELECTRICAL SITE PLAN
ES103 ELECTRICAL SITE PLAN
ES104 ELECTRICAL SITE PLAN
ES105 ELECTRICAL SITE PLAN
ES106 CATHODIC PROTECTION SITE PLAN
ES401 ELECTRICAL SITE ENLARGED PLANS
ES501 ELECTRICAL SITE DETAILS
ES502 ELECTRICAL SITE DETAILS
ES503 ELECTRICAL SITE DETAILS
ES504 ELECTRICAL SITE DETAILS
ES701 ELECTRICAL SITE DEMOLITION SINGLE LINE DIAGRAM
ES702 ELECTRICAL SITE SINGLE LINE DIAGRAM
EG101 LIGHTNING PROTECTION SYSTEM PLAN
EG501 LIGHTNING PROTECTION SYSTEM DETAILS
EL101A FIRST FLOOR LIGHTING PLAN - AREA A
EL101B FIRST FLOOR LIGHTING PLAN - AREA B
EL101C FIRST FLOOR LIGHTING PLAN - AREA C
EL101D FIRST FLOOR LIGHTING PLAN - AREA D
EL102A SECOND FLOOR LIGHTING PLAN - AREA A
EL102B SECOND FLOOR LIGHTING PLAN - AREA B
EL102C SECOND FLOOR LIGHTING PLAN - AREA C
EL501 LIGHTING DETAILS
EL502 LIGHTING DETAILS
EL503 LIGHTING DETAILS - PLATES
EL504 LIGHTING DETAILS - PLATES
EL601 LUMINAIRE SCHEDULE AND ENLARGED MEZZANINE PLANS
EP101A FIRST FLOOR POWER PLAN - AREA A
EP101B FIRST FLOOR POWER PLAN - AREA B
EP101C FIRST FLOOR POWER PLAN - AREA C
EP101D FIRST FLOOR POWER PLAN - AREA D
EP102A SECOND FLOOR POWER PLAN - AREA A
EP102B SECOND FLOOR POWER PLAN - AREA B
EP102C SECOND FLOOR POWER PLAN - AREA C
EP103 ROOF POWER PLAN - OVERALL
EP401 ENLARGED PLANS - ELECTRICAL ROOMS AND ELEVATED MEZZANINE
EP402 ENLARGED PLANS - UPS ROOMS
EP403 ENLARGED PLANS - TELECOMMUNICATIONS ROOMS
EP501 ELECTRICAL DETAILS
EP502 ELECTRICAL DETAILS
EP601 MECHANICAL EQUIPMENT SCHEDULE
EP602 PANELBOARD SCHEDULES
EP603 PANELBOARD SCHEDULES
EP604 PANELBOARD SCHEDULES
EP605 PANELBOARD SCHEDULES
EP606 PANELBOARD SCHEDULES
EP607 PANELBOARD SCHEDULES
EP608 PANELBOARD SCHEDULES
EP701 ELECTRICAL SINGLE-LINE DIAGRAM
EP702 ELECTRICAL UPS SUBSYSTEM DIAGRAM
14. ELECTRICAL: 55
16. TELECOMMUNICATIONS
T-001 TELECOMMUNICATIONS LEGEND, GENERAL NOTES AND ABBREVIATIONS
TS100 TELECOMMUNICATIONS SITE KEY PLAN
TD101 TELECOMMUNICATIONS SITE DEMOLITION PLAN
TS101 TELECOMMUNICATIONS SITE PLAN
TS102 TELECOMMUNICATIONS SITE PLAN
TS103 TELECOMMUNICATIONS SITE PLAN
TS104 TELECOMMUNICATIONS SITE PLAN
TS105 TELECOMMUNICATIONS SITE PLAN
TS501 TELECOMMUNICATIONS SITE DETAILS
TS502 TELECOMMUNICATIONS SITE DETAILS
T-101Z FIRST FLOOR TELECOMMUNICATIONS SERVING ZONES
T-101A FIRST FLOOR TELECOMMUNICATIONS PLAN - AREA A
T-101B FIRST FLOOR TELECOMMUNICATIONS PLAN - AREA B
T-101C FIRST FLOOR TELECOMMUNICATIONS PLAN - AREA C
T-101D FIRST FLOOR TELECOMMUNICATIONS PLAN - AREA D
T-102Z SECOND FLOOR TELECOMMUNICATIONS SERVING ZONES
T-102A SECOND FLOOR TELECOMMUNICATIONS PLAN - AREA A
T-102B SECOND FLOOR TELECOMMUNICATIONS PLAN - AREA B
T-102C SECOND FLOOR TELECOMMUNICATIONS PLAN - AREA C
T-201 TELECOMMUNICATIONS ELEVATIONS - COMM 104
T-202 TELECOMMUNICATIONS ELEVATIONS - COMM 129
T-203 TELECOMMUNICATIONS ELEVATIONS - IIQC 260
T-401 ENLARGED TELECOMMUNICATIONS PLANS - COMM ROOMS
T-402 ENLARGED TELECOMMUNICATIONS PLANS - SERVER ROOMS
T-403 ENLARGED PLAN - CABLE TRAY IN TRENCH AND UNDER RAF
T-404 ENLARGED PLAN - IIQC SECURE AREA LAN/SERVER ROOMS
T-501 TELECOMMUNICATIONS DETAILS
T-502 TELECOMMUNICATIONS DETAILS
T-503 TELECOM GROUNDING DETAILS
T-701 TELECOMMUNICATIONS RISER DIAGRAMS
T-702 TELECOMMUNICATIONS RISER DIAGRAMS
16. TELECOMMUNICATIONS: 31
17. SECURITY
X-001 SECURITY LEGEND AND ABBREVIATIONS
X-002 SECURITY GENERAL NOTES AND SCHEDULES
X-101 FIRST FLOOR SECURITY PLAN - OVERALL
X-101A FIRST FLOOR SECURITY PLAN - AREA A
X-101B FIRST FLOOR SECURITY PLAN - AREA B
X-101C FIRST FLOOR SECURITY PLAN - AREA C
X-101D FIRST FLOOR SECURITY PLAN - AREA D
X-102 SECOND FLOOR SECURITY PLAN - OVERALL
X-102A SECOND FLOOR SECURITY PLAN - AREA A
X-102B SECOND FLOOR SECURITY PLAN - AREA B
X-102C SECOND FLOOR SECURITY PLAN - AREA C
X-501 SECURITY DETAILS
X-502 CCTV DETAILS
X-503 CONDUIT MOUNTING ON PARTITION DETAILS
X-504 CONDUIT MOUNTING ON PARTITION DETAILS
X-505 CONDUIT MOUNTING ON PARTITION DETAILS
X-506 CONDUIT MOUNTING ON PARTITION DETAILS
X-507 CONDUIT MOUNTING ON PARTITION DETAILS
X-701 SECURITY RISER DIAGRAMS
17. SECURITY: 19
18.AUDIO VISUAL
TA001 AUDIO VISUAL LEGEND, GENERAL NOTES AND ABBREVIATIONS
TA101A FIRST FLOOR AUDIO VISUAL PLAN - AREA A
TA101B FIRST FLOOR AUDIO VISUAL PLAN - AREA B
TA101C FIRST FLOOR AUDIO VISUAL PLAN - AREA C
TA101D FIRST FLOOR AUDIO VISUAL PLAN - AREA D
TA102A SECOND FLOOR AUDIO VISUAL PLAN - AREA A
TA102B SECOND FLOOR AUDIO VISUAL PLAN - AREA B
TA102C SECOND FLOOR AUDIO VISUAL PLAN - AREA C
TA201A FIRST FLOOR AUDIO VISUAL RCP - AREA A
TA201D FIRST FLOOR AUDIO VISUAL RCP - AREA D
TA202B SECOND FLOOR AUDIO VISUAL RCP - AREA B
TA202C SECOND FLOOR AUDIO VISUAL RCP - AREA C
TA400 AUDIO VISUAL ELEVATIONS
TA401 AUDIO VISUAL ELEVATIONS
TA501 AUDIO VISUAL DETAILS
TA601 AUDIO VISUAL FUNCTIONAL DIAGRAMS
TA602 AUDIO VISUAL FUNCTIONAL DIAGRAMS
TA603 AUDIO VISUAL FUNCTIONAL DIAGRAMS
TA604 AUDIO VISUAL FUNCTIONAL DIAGRAMS
TA605 AUDIO VISUAL FUNCTIONAL DIAGRAMS
18.AUDIO VISUAL: 20
Grand total: 460
F22 FTU, Training Support Squadron Facility
Joint Base Langley-Eustis (JBLE)
00 22 13.00 20
SUPPLEMENTARY INSTRUCTIONS TO OFFERORS
OFFEROR’S NAME:
CONTRACT LINE ITEM SCHEDULE
CLIN Description Unit Unit
Amount
Base Proposal
0001 All work, labor, materials, and equipment required to construct the Training Support Squadron Facility (TRSS-
F), including all building related construction within the 5’ line, complete as prescribed in the construction documents excluding work described in all other CLINs.
Source of funding is MILCON.
LS
0002 All work, labor, materials, and equipment required to construct the TRSS-F site improvements, including all construction outside of the 5’ line, complete as prescribed in the construction documents excluding work described in all other CLINs.
0003 All work, labor, materials, and equipment by Dominion Energy required to construct electrical service to the new TRSS-F facility, including the 35kV pad-mounted switch, building pad-mounted transformer, 35kV conductors and terminations, and the connection to the existing JBLE 34.5kV electrical distribution system, complete as prescribed in the in the construction documents excluding work described in all other
CLINs.
0004 All work, labor, materials, and equipment required to construct natural gas service to the new TRSS-F facility by
Virginia Natural Gas, including the distribution system to the new facility, the meter, the regulator, and all connection fees, complete as prescribed in the in the construction documents excluding work described in all other CLINs.
0005 Provide unit price for all work, labor, materials, and equipment required to dispose and replace any unsatisfactory soils, complete as prescribed in the construction documents, excluding work described in all other CLINs. Option to be exercised within 365 days of contract Notice To Proceed in accordance with FAR 52.217-7.
For bidding purposes Offeror shall assume 1 lot equals 250CY and a total quantity of 1 Lot.
lot
CLIN Description Unit Unit
Amount
Total Base
0006 Bid Option 1
All work, labor, materials, and equipment required to furnish and install Audio-Visual (AV) Equipment complete as prescribed in the construction documents excluding work described in all other CLINs. Option to be exercised within 365 days of contract Notice To Proceed in accordance with FAR 52.217-7.
Source of funding is NON-MILCON.
0007 BID OPTION 2
All work, labor, materials, and equipment required to furnish and install Fixtures, Furniture and Equipment (FF&E) complete as prescribed in the construction documents excluding work described in all other CLINs. Option to be exercised within
365 days of contract Notice To Proceed in accordance with FAR
52.217-7.
Source of funding is NON-MILCON.
0008 BID OPTION 3
All work, labor, materials, and equipment required to construct Offsite Communications improvements from connection point at HH179E (including structure HH179E) to Building 330, with exception of 24 Strand Single Mode Fiber Option cable from TRSS-F to telcon room inside Bldg 330 (24 Strand FO Cable is base bid) complete as prescribed in the construction documents excluding work described in all other CLINs. Option to be exercised within 365 days of contract Notice To Proceed in accordance with FAR 52.217-7.
0009 BID OPTION 4
Provide unit price for all work, labor, materials, and equipment required to dispose any other-than-clean soil complete as prescribed in the construction documents, including but not limited to specification section 01 57 19
Temporary Environmental Controls 01 57 19 ATTACHMENT JBLE-
Langley Environmental Special Conditions para 1.1.2.2, excluding work described in all other CLINs. Option to be exercised within 365 days of contract Notice To Proceed in accordance with FAR 52.217-7.
For bidding purposes Offeror shall assume 1 lot equals 250CY and a total quantity of 1 Lot.
Unit Price for each Lot
Lot
TOTAL BASE AMOUNT (CLINS 0001, 0002, 0003,
0004, 0005)
TOTAL NON-MILCON OPTIONS (CLINS 0006, 0007)
CLIN Description Unit Unit
Amount
TOTAL MILCON OPTIONS (CLINS 0008, 0009)
NOTES FOR CONTRACT LINE ITEM (CLIN) SCHEDULE
NOTE NO. 1. To better facilitate the receipt and proposal process, all modifications to proposals are to be submitted on copies of the latest Contract Line Item
(CLIN) schedules as published in the solicitation or the latest amendment thereto. In lieu of indicating additions/deductions to line items, all Offerors should state their revised prices for each item.
NOTE NO. 2. Offerors must insert a price on all numbered items including unit prices and options of the CLIN Schedule. Failure to do so may result in the offer being unacceptable.
NOTE NO. 3. The Offeror’s Base Bid and all Options will be evaluated. In accordance with 52.217-5, Evaluation of Options, the Government will evaluate offers for award purposes by adding the total price for all options to the total price for the basic requirement. Evaluation of options will not obligate the Government to exercise the option(s).
End of Section
SECTION 01 11 00
SPECIAL CONDITIONS
FOR MILCON PROJECTS
PART 1 GENERAL
1.1 SUBMITTALS
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are for Contractor Quality Control approval. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government.
"G, AE" code is applied where Architect/Engineer review and approval is required. "G, RO" code is applied where government Resident Office review and approval is required. Submittals with an "S" are for inclusion in the Sustainability eNotebook, in conformance to this section. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:
SD-03 Product Data
Material Safety Data Sheets (MSDS)
Recycling Report
Trip tickets
Affirmative Procurement Report
Exemption Form, Annex B to LAFB Affirmative Procurement Plan 32-7080
All Employee Names and Social Security Numbers
Work Clearance Request (Air Force Form 103)
Quality Control (QC) Report
SD-11 Closeout Submittals
Survey Report
Metadata
Deliverables and Final As-Builts
Three copies of Computer-Aided Drafting and Design (CADD) digital final as-built drawings on CD's
"Redline" As-Built Drawings
Warranty of Construction
Equipment Warranty Certificate
SECTION 01 11 00 Page 1
Equipment Warranty/Guarantee Records
DD Form 1354 Acceptance and Transfer of Real Property Facilities
1.1.1 Submittal Procedures
1.1.1.1 Schedule of Material Submittals (Air Force Form 66)
Information, shop drawings, certificates, test data, etc., listed on the attached AF Form 66, Schedule of Material Submittals, shall be submitted for approval by the Contracting Officer, or his/her designated representative in accordance with the General Provisions. Whenever in this contract materials or drawings are required to be submitted by the Contractor to the Contracting Officer for approval and the material or drawings submitted are at variance with the specifications or Government drawings, but are, nevertheless, approved by the Contracting Officer, inadvertently and without consciousness of the variance, and regardless that a closer review could have revealed the variance, then such approval shall not be final unless the Contractor expressly noted in a memorandum to the Contracting Officer, on the material submittal or drawing that "this material or drawing varies from specifications in the following aspects" or uses other works of similar clear meaning. In the event of such an inadvertent, erroneous approval, the Contracting Officer, upon discovering the variance at any stage, have the right to require the Contractor to do such rework and/or material replacement as is necessary to obtain compliance with the specifications, and the expense of such rework and material replacement shall be borne solely by the Contractor.
a. Submittals for technical compliance of finishes may be made individually for each material. SUBMITTALS FOR PATTERN, COLOR, TEXTURE, ETC., SHALL BE MADE SIMULTANEOUSLY FOR EACH ROOM OR AREA.
Finishes shall be scheduled for each room/area to include surface, type material, manufacturer, brand name or product number, and space for the Government selection of pattern/color.
EXAMPLE:
Room 100 Floor: Vinyl Tarkett Reliant (62107 Adobe) Floor: Carpet Milliken Magistrate (21 Clan Henna) Wall: Paint Pittsburgh Spread-Flow (white #21) Wall: Vinyl Flex-Wall Pls. In a Roll (Rajah Blue) Wainscot: Paneling Masonic Fireguard (walnut) Ceiling: Acoustic Gold Bond Acoustinet (fissure #21) Trim: Paint Glidden Easy-Enamel (0021 blue)
1.2 SCOPE OF WORK
The work under this project consists of demolition of pavements, utilities and miscellaneous site features. Construction of the multi-story Training Support Squadron Facility (TRSS-F), pavements, utilities and incidental related work.
1.2.1 Work Hours
Normal duty hours for Langley AFB, JBLE are 0730 through 1630, Monday through Friday. Work on weekends, recognized Federal holidays, or other than normal duty hours must be coordinated with the Contracting Officer (CO) or his/her designated representative.
SECTION 01 11 00 Page 2
1.2.2 General Working Conditions
a. Work shall be performed in such a manner as to cause minimum disruption to the users in the area.
b. The Contractor shall notify the Contracting Officer or his/her designated representative when he intends to work so Government inspection can be provided while work is in progress.
c. Assume existing elevators are unavailable for contractor use.
1.3 ORDER OF WORK
The Contractor shall coordinate all work with the Contracting Officer, or his/her designated representative. Before starting work at the job site, provide five days' notice to the Contracting Officer or his/her designated representative.
1.4 APPLICABLE CODES AND REGULATIONS
The latest edition of the following Building Codes shall be used for all construction under this contract:
o Air Force Engineering Technical Letter ETL 01-1, Reliability and Maintainability (R&M) Design Checklist o American National Standards Institute (ANSI) o American Standards for Testing Materials (ASTM) o Americans with Disabilities Act (ADA) o ANSI C-2, National Electrical Safety Code (QIESC) o Applicable Unified Facilities Guide Specifications o Institute of Electrical and Electronics Engineers (IEEE) o International Building Code o International Code Council (ICC) International Plumbing Code o International Fire Code o International Mechanical Code o International Society of Automation (ISA) o Langley Air Force Base Design Compatibility Guidelines, March 2006 or most current verison.
o Langley AFB, JBLE Electrical, Fire, and Communications Design
Standards - latest edition o Unified Facilities Criteria (UFC) 1-200-02, High Performance and
Sustainment Building (HPSB) Requirements o Life Safety Code, NFPA 101 o MIL Handbook 1190 o National Electrical Code (NEC) o National Electrical Manufacturers Association (NEMA) o National Fire Protection Association (NFPA) o National Fire Protection Association Codes (NFPA) - latest edition o Supervisory Control and Data Acquisition (SCADA) o Underwriters Laboratories, Inc. (UL) o Unified Facilities Criteria (UFC) 3-600-01, Fire Protection
Engineering for Facilities o Unified Facilities Criteria (UFC) 4-020-01, DoD Security Engineering -
Facilities Planning Manual o 25AF/A4C Mission Critical Facility Engineering Standard (MCFES) 15-01:
Facility Electrical and Mechanical Infrastructure Redundancy Requirements, dated 27 Oct 2015 or most current version.
SECTION 01 11 00 Page 3
NOTE: If there is a conflict between these codes or regulations and these contract specifications, the most stringent requirements shall apply at all times.
1.5 CONSTRUCTION STANDARDS
1.5.1 General
The Contractor is reminded that the construction site must be operated and maintained according to these specifications and is subject to inspection and enforcement according to all federal, state and local codes/regulations.
1.5.2 Office Trailers and Storage Units
1.5.2.1 Office Trailers
If a trailer is required for work and at the discretion of the Government, an office trailer may be located at the project site. The Contractor shall request Contracting Officer approval for the trailer location. The Contractor shall make the request in writing at least fourteen calendar days prior to placement of trailer at site. All office trailers shall be located in areas as directed by the Contracting Officer or his/her designated representative. Any office trailer shall be provided with a skirt on all sides, in like new condition, and painted either Langley Brown (Federal Standard 595a, 20100), Langley Beige, or white. Office trailers in need of painting and / or repairs or that are in an unsightly condition will not be allowed at the project site. Displayed on the exterior of all trailers shall be a nameplate which has the name of the Contractor's company, name for Contractor's point(s) of contact (POC) and telephone number where he or she can be reached, contract number, project number, title and date trailer was placed on site where located.
1.5.2.2 Storage Units
The Contractor shall request Contracting Officer approval for the siting, size and color of Storage Units, CONNEX boxes and dumpsters. The Contractor shall not bring any such items to the job site without the Contracting Officer's approval. All storage units shall be painted Langley Brown (Federal Standard 595a, 20100), Langley Beige or white.
Displayed on the exterior of all storage units shall be a nameplate which has the name of the Contractor's company, name for Contractor's point(s) of contact (POC) and telephone number where he or she can be reached, contract number, project number, title and date unit was placed on site where located.
1.5.3 On-Site Storage Units
Availability and size of material lay down area shall be restricted as noted on the contract documents or as discussed during the preconstruction conference. The Contractor shall consolidate all bulk or large quantities of materials at the construction site in area(s) approved by the CO. All such items shall be stored neatly grouped together. Bulky or unsightly construction materials, heavy or light equipment or tanks shall not be delivered to or stored on the construction site for any period longer than seven calendar days prior to use, installation in the project or start of construction. The Contractor shall store all supplies and equipment on project site to preclude theft or damage. Protection and security for materials and equipment on site is the sole responsibility of the
SECTION 01 11 00 Page 4
Contractor. The Contractor shall not use any area(s) for material or equipment storage that has not been approved by the CO or his/her designated representative.
1.5.4 Fencing and Screening
Fencing and Screening, replace the paragraph to read "Contractor shall enclose the construction and material storage / lay down areas with a temporary chain link fence to a minimum height of six (6) feet or the area shall be secured with required physical barriers as otherwise required.
Temporary fencing shall be completely secured at the top and bottom to prevent access. These areas shall also be screened from view in accordance with base standards or as otherwise specified. Screening shall be fabricated of 100 percent Polypropylene, woven, 92 percent blockage fabric that has been mechanically attached to the fence for the full height of the fence. The edges of each section of screening fabric shall be finished with a reinforced hem. Attachment points shall be reinforced fabric built into the hem or metal grommets built into the hem. All fabric used for screening of the construction and material storage / lay down areas shall be UV rated and dark brown or dark bronze in color unless otherwise approved by the Base Civil Engineer (BCE). Fence screening fabric shall be inspected weekly to insure all sections remain properly in-stalled and taut at all times."
1.5.5 Locksets
If locksets are installed as a result of this project, the Contractor shall provide cylinders and cores for new locks. Cylinders and cores that the Contractor provides shall have seven-pin tumblers using the A2 system and WB keyway - except for dormitories, which use the A4 system and WC keyway. All cylinders will be from a single manufacturer. All cores will be stamped with a key control symbol in a concealed place on the core.
(For information only - the Best Premium WB Keyway, 7-pin core is part number 1CP7WB2.) The cylinders will be fully compatible with products of the Best Lock Corporation, which have interchangeable cores that are removable by special control keys.
Provide and submit a grand master keying system and a sub-master keying system for the building that is an extension of the existing Langley AFB, JBLE keying system. Best Lock Corporation can key cores and provide keys in accordance with the Langley AFB, JBLE grand master keying system; the base grand master keying system will not be made available to outside contractors. Key the equipment spaces and mechanical rooms separately from the building systems. Key them alike to the existing Langley AFB, JBLE systems for equipment and mechanical space doors. Prior to installing any lock cylinder or cores, the contractor shall coordinate with the Langley AFB, JBLE locksmith to ensure compliance with the grand master keying system and master keying sequence, and that the proposed lock hardware will meet requirements of this specification.
1.5.6 Communications
The Contractor shall design and install new communications in accordance with the most current version of 633d COMMUNICATIONS SQUADRON LANGLEY AIR FORCE BASE TELECOMMUNICATIONS BUILDING CABLING SYSTEMS STANDARDS (Langley AFB, JBLE), Attachment to Specification 27 10 00 BUILDING
TELECOMMUNICATIONS CABLING SYSTEM.
SECTION 01 11 00 Page 5
1.5.7 Electrical Identification
1.5.7.1 Panels
Distribution Panels are to be labeled in accordance with LANGLEY ELECTRICAL STANDARD - MEDIUM VOLTAGE LABELING DETAILS, sheets E-203 and E-204 dtd 12/13/2019 or newer. Consult the Base Civil Engineers Project Manager for newest revision.This labeling scheme is generally described in construction documents, drawing Sheet EP501.
1.5.7.2 Transformers, Switches, Cabling
Transformers, Switches, and Cabling are to be labeled in accordance with LANGLEY ELECTRICAL STANDARD- MEDIUM VOLTAGE LABELING DETAILS, sheets E-203 and E-204 dtd 12/13/2019 or newer. Consult the Base Civil Engineers Project Manager for newest revision. This labeling scheme for switches is generally described in construction documents, drawing sheet EP501. This labeling scheme for cabling is generally described in construction documents, in written specifications.
1.6 CONTRACTOR OPERATIONS
1.6.1 Grassy Areas
Grass and weed growth in excavated materials that are stockpiled on site shall be controlled or cut weekly. Weeds and grass within the construction site shall also be controlled or cut weekly and any bushes or shrubs shall be trimmed monthly. Areas disturbed by construction or those areas required by the plans to be "re-seeded" shall be re-established by hydroseeding only. Straw shall not be used as a cover for freshly seeded areas.
1.6.2 Privately Owned Vehicles (POVs)
POVs used by Contractor personnel to commute to work are required to park in existing parking lots. Contractor or Contractor's employees, including subcontractors, shall not park any personally owned vehicle (POV) or company or delivery vehicle on grassy areas near or in the construction site without prior approval from the Contracting Officer, or his/her designated representative. When allowed, parking on grassy areas will only be for short-term delivery purposes (to include heavy tools, equipment, construction materials, etc.). Use designated hard surfaces or existing parking lots near or within the project site for 1 of POVs or company or delivery vehicles. Tire and track impressions (ruts) created on wet or soft soil by vehicles or equipment used in the Contractor's operations shall not be left for more than one day after removal of such vehicle or equipment that caused the rutting. The Contractor shall restore the affected area(s) of the site to its original condition within that one-day period.
1.6.3 Site Cleanup
During construction, the Contractor shall maintain all areas in a neat and orderly manner. Contractor shall keep the construction site cleaned daily of all construction trash, trash generated by employees, debris or demolished building materials. If the work areas are not kept neat and orderly, the Contractor must return to the area to correct the
SECTION 01 11 00 Page 6 unacceptable condition. During the laying of asphalt roads, streets or parking surfaces, areas soiled by residual asphalt shall be cleaned daily. The Contractor shall treat with lime entrances and exits to asphalt work site at his/her own expense.
1.6.4 Access Routes
Access routes to this project shall be limited through the Base as shown on the plans. The Contractor shall not use the gates at King Street Bridge or LaSalle Gate (Nealy Avenue) for haul route entry or exit. When entering and exiting the base, the haul route shall be through the West Gate only.
1.6.5 Removal of Formwork
The Contractor shall remove all concrete formwork and boards within fourteen calendar days after concrete pour.
1.6.6 Noise Control
The Contractor shall comply with all applicable state, local and installation laws, ordinances and regulations relative to noise control, to include applicable quiet hours exclusive to Langley AFB, JBLE. Work site is in a residential area of Langley AFB, JBLE. There shall be absolutely no construction activities in or around the construction site prior to or after the hours designated in "Work Hours" paragraph above without an approval from the Contracting Officer, or his/her designated representative. This restriction also applies to holidays.
1.6.7 Excavations
All trenches/excavations shall be back filled and compacted to 95 percent of maximum Proctor density. Trenches will be top dressed with no less than three inches of shifted topsoil and then compacted. The finished area will be free of all debris, rocks and then graded to conform to the surrounding area.
1.6.8 In-Ground Obstructions
Any type of raised obstructions shall have the surrounding soil backfilled, compacted to 95 percent of maximum Proctor density, and graded. The area will be top dressed as above to within three inches of the top of obstruction.
1.6.9 Architectural Compatibility
Due to Langley AFB, JBLE's distinct historic architecture and the high visitor traffic it receives, several special actions are required during construction:
a. The Contractor is solely responsible for spillage from his/her vehicles and such spillage shall be cleaned up immediately. For the duration of this contract and on a daily basis, the Contractor shall remove from all base roads and streets asphalt, mud, soil, rocks, trash and debris that result from his/her construction operation on base. All roads or streets affected shall be cleaned before close of business on the particular day affected. In the case of asphalt, roads will be cleaned and/or treated with lime immediately upon detection.
SECTION 01 11 00 Page 7
b. Newly placed concrete curbing and sidewalks shall match existing, adjacent concrete in color and texture.
c. Unprimed or factory-finished equipment installed on the exterior of facilities shall be painted with two coats of brown paint to…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .