SHEET OF
DRAWING
PROJECT NUMBER
CHECKED BY
SCALE
DATE
CHECKED BY
DESIGNED BY
DRAWN BY
A/E
FO
R
ES
T:
D R
A W
IN
G
PR
O
JE
C
T N
A M
E:
N A
M E:
FOREST
REGION
SOUTHWEST
PACIFIC
DATENO. REVISIONS
R5
SERVICE
U S D A
TI
TL
E S
H E
E T
A N
D L
O C
A
TI
O N
M A
P
AS NOTED
12MAR2020
TMATHER
RSONZA
TMATHER
C
LE
V
EL
A N
D N
A
TI
O N
A L
FO
R
ES
T
1 3
CALIFORNIA CLEVELAND NATIONAL FOREST
2020 CORONA STATION AND TEMESCAL STATION
FENCE CONSTRUCTION
C O
R O
N A
S T
A T
IO
N
A N
D T
E M
E S
C A
L S
T A
T
IO
N F
E N
C E
C O
N S
T R
U C
T
IO
N
AutoCAD SHX Text Version 2.0 12/19/01, FILE: USFS-Dsize(24x36).dwg
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text D
AutoCAD SHX Text F
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text V
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text T
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text M
AutoCAD SHX Text T
AutoCAD SHX Text R
AutoCAD SHX Text A
AutoCAD SHX Text P
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text U
AutoCAD SHX Text T
AutoCAD SHX Text L
AutoCAD SHX Text U
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text G
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text p
AutoCAD SHX Text
INTERSTATE HIGHWAYS
AutoCAD SHX Text
U.S. HIGHWAYS
AutoCAD SHX Text
LEGEND
AutoCAD SHX Text San Diego
AutoCAD SHX Text o
AutoCAD SHX Text Sacramento
AutoCAD SHX Text San Francisco
AutoCAD SHX Text o
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text O
AutoCAD SHX Text o
AutoCAD SHX Text
AutoCAD SHX Text p
AutoCAD SHX Text
AutoCAD SHX Text Reno
AutoCAD SHX Text o
AutoCAD SHX Text
AutoCAD SHX Text o
AutoCAD SHX Text p
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text p
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Hemet
AutoCAD SHX Text Julian
AutoCAD SHX Text Hot Springs
AutoCAD SHX Text Warner
AutoCAD SHX Text Alpine
AutoCAD SHX Text Corners
AutoCAD SHX Text Cameron
AutoCAD SHX Text Perris
AutoCAD SHX Text Corona
AutoCAD SHX Text Elsinore
AutoCAD SHX Text Temecula
AutoCAD SHX Text Lake
AutoCAD SHX Text Capistrano
AutoCAD SHX Text San Juan
AutoCAD SHX Text Oceanside
AutoCAD SHX Text San Diego
AutoCAD SHX Text Escondido
AutoCAD SHX Text Ramona
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Pala
AutoCAD SHX Text Cleveland National Forest
AutoCAD SHX Text
DRAWING INDEX
AutoCAD SHX Text
TITLE SHEET AND LOCATION MAP
AutoCAD SHX Text 1.
AutoCAD SHX Text 3.
AutoCAD SHX Text 2.
AutoCAD SHX Text
CORONA FIRE STATION SITE PLAN
AutoCAD SHX Text p
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
CORONA FIRE STATION
AutoCAD SHX Text
TEMESCAL FIRE STATION SITE PLAN
AutoCAD SHX Text
TEMESCAL FIRE STATION
PROJECT NUMBER
CHECKED BY
SCALE
DATE
CHECKED BY
DESIGNED BY
DRAWN BY
A/E
FO
R
ES
T:
D R
A W
IN
G
PR
O
JE
C
T N
A M
E:
N A
M E:
FOREST
REGION
SOUTHWEST
PACIFIC
DATENO. REVISIONS
R5
SERVICE
U S D A
C O
R O
N A
F
IR
E S
TA
TI
O N
S
IT
E P
LA
N
1" =30'
12MAR2020
TMATHER
RSONZA
TMATHER
C
LE
V
EL
A N
D N
A
TI
O N
A L
FO
R
ES
T
2 3
C O
R O
N A
S
TA
TI
O
N A
N D
T E
M E
S C
A L
S
TA
TI
O
N
FE
N
C E
C O
N S
TR
U
C
TI
O N
AutoCAD SHX Text
BARRACKS
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
BUILDING ON ADJACENT PROPERTY
AutoCAD SHX Text
BARRACKS
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
SHED
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
LEGEND:
AutoCAD SHX Text
FENCE
AutoCAD SHX Text NOTES: 1. ALL EXISTING SITE FEATURES ARE APPROXIMATE AND SHOULD BE VERIFIED BY CONTRACTOR. IT SHALL ALL EXISTING SITE FEATURES ARE APPROXIMATE AND SHOULD BE VERIFIED BY CONTRACTOR. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO PROTECT EXISTING SITE FEATURES AND ALL UTILITIES FROM DAMAGE. CONTRACTOR SHALL REPAIR AT NO COST TO THE GOVERNMENT, ALL DAMAGES TO ANY UTILITIES CAUSED BY THE CONTRACTOR'S ACTIONS. THE UTILITIES TO THE SITE MUST BE MAINTAINED AT ALL TIMES. IF THE CONTRACTOR DAMAGES A UTILITY, THE CONTRACTOR MUST COMPLETE REPAIRS TO THE DAMAGED UTILITY WITHIN 8 HOURS OF THE DAMAGE. IF A WATER FACILITY IS DAMAGED, THE CONTRACTING OFFICER MUST BE IMMEDIATELY NOTIFIED SO THAT THE GOVERNMENT'S WATER SYSTEM OPERATOR CAN BE CONSULTED AS TO THE CORRECT REPAIR PROCEDURE. AFTER ANY WATER DAMAGE, DISINFECTION AND BACTERIOLOGICAL TESTING MUST BE PERFORMED BY A STATE OF CALIFORNIA CERTIFIED DISTRIBUTION OPERATOR WITH A MINIMUM OF D-1 CERTIFICATION WITHIN 24 HOURS OF THE COMPLETION OF REPAIRS. 2. NEW FENCE LOCATION TO BE IN SAME LOCATION AS EXISTING FENCE EXCEPT IN DRIVEWAY VICINITY. NEW FENCE LOCATION TO BE IN SAME LOCATION AS EXISTING FENCE EXCEPT IN DRIVEWAY VICINITY. REMOVAL OF EXISTING FENCE TO BE COORDINATED WITH INSTALLATION OF NEW FENCE SO THAT SITE IS NOT LEFT UNSECURED AT THE END OF EACH DAY 3. ALL EXISTING TREES/BRUSH TO REMAIN. ALL EXISTING TREES/BRUSH TO REMAIN. 4. IF OPTION ITEM FOR AUTOMATIC GATE AND OPERATOR IS AWARDED CONTRACTOR SHALL LOCATE IF OPTION ITEM FOR AUTOMATIC GATE AND OPERATOR IS AWARDED CONTRACTOR SHALL LOCATE OPERATOR, TRENCHING AND ELECTRICAL RUNS IN LOCATION AS DESIGNATED BY THE CONTRACTING OFFICER'S REPRESENTATIVE. LOCATION OF ELECTRICAL METER CONNECTION POINT, JUNCTION BOX AND TRENCHING SHOWN IS APPROXIMATE. 5. THE ELECTRICAL TRENCH SHALL BE APPROXIMATELY SIX INCHES WIDE AND A MINIMUM TWENTY FOUR THE ELECTRICAL TRENCH SHALL BE APPROXIMATELY SIX INCHES WIDE AND A MINIMUM TWENTY FOUR INCHES DEEP. INSTALL ELECTRICAL CONDUIT IN TRENCH AND BACKFILL SOIL MATERIAL AND COMPACT.
AutoCAD SHX Text Version 2.0 12/19/01, FILE: USFS-Dsize(24x36).dwg
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text D
AutoCAD SHX Text F
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text V
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text T
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text M
AutoCAD SHX Text T
AutoCAD SHX Text R
AutoCAD SHX Text A
AutoCAD SHX Text P
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text U
AutoCAD SHX Text T
AutoCAD SHX Text L
AutoCAD SHX Text U
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text G
A
PROJECT NUMBER
CHECKED BY
SCALE
DATE
CHECKED BY
DESIGNED BY
DRAWN BY
A/E
FO
R
ES
T:
D R
A W
IN
G
PR
O
JE
C
T N
A M
E:
N A
M E:
FOREST
REGION
SOUTHWEST
PACIFIC
DATENO. REVISIONS
R5
SERVICE
U S D A
TE
M
E S
C A
L S
TA
TI
O N
S
IT
E P
LA
N
1/4" = 1'
12MAR2020
TMATHER
RSONZA
TMATHER
C
LE
V
EL
A N
D N
A
TI
O N
A L
FO
R
ES
T
3 3
C O
R O
N A
S T
A T
IO
N
A N
D T
E M
E S
C A
L S
T A
T
IO
N F
E N
C E
C O
N S
T R
U C
T
IO
N
AutoCAD SHX Text
BARRACKS
AutoCAD SHX Text
RESIDENCE
AutoCAD SHX Text
GARAGE
AutoCAD SHX Text
TO CORONA
AutoCAD SHX Text
TO ELSINORE
AutoCAD SHX Text
TEMESCAL CYN ROAD
AutoCAD SHX Text N
AutoCAD SHX Text
SIGN
AutoCAD SHX Text
SPRINGKLER CONTROLS
AutoCAD SHX Text
DUMPSTER
AutoCAD SHX Text
BARRACKS SEPTIC TANK
AutoCAD SHX Text
EQUIP/ GARAGE
AutoCAD SHX Text
OFFICE & STORAGE
AutoCAD SHX Text
GAS & OIL HOUSE
AutoCAD SHX Text
PROPOSED FENCE
AutoCAD SHX Text
BULLETIN BOARD
AutoCAD SHX Text
MAILBOX
AutoCAD SHX Text
APPROXIMATE LOCATION OF ELECTRICAL JUNCTION BOX CONNECTION POINT
AutoCAD SHX Text
APPROXIMATE LOCATION OF TRENCHING FOR AUTOMATIC GATE ELECTRICAL
AutoCAD SHX Text
INSTALL LOCK OPEN POST
AutoCAD SHX Text
ROCK/GRAVEL AREA
AutoCAD SHX Text
EXISTING ELECTRICAL PANEL LOCATION
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
LEGENDS:
AutoCAD SHX Text
PROPOSED FENCE
AutoCAD SHX Text
EXISTING FENCE
AutoCAD SHX Text
PROPOSED ELECTRIC
AutoCAD SHX Text
SEWER
AutoCAD SHX Text
LEACH
AutoCAD SHX Text
SPRINKLER CONTROLS
AutoCAD SHX Text
TREE
AutoCAD SHX Text NOTES: 1. ALL EXISTING SITE FEATURES ARE APPROXIMATE AND SHOULD BE VERIFIED BY CONTRACTOR. IT SHALL ALL EXISTING SITE FEATURES ARE APPROXIMATE AND SHOULD BE VERIFIED BY CONTRACTOR. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO PROTECT EXISTING SITE FEATURES AND ALL UTILITIES FROM DAMAGE. CONTRACTOR SHALL REPAIR AT NO COST TO THE GOVERNMENT, ALL DAMAGES TO ANY UTILITIES CAUSED BY THE CONTRACTOR'S ACTIONS. THE UTILITIES TO THE SITE MUST BE MAINTAINED AT ALL TIMES. IF THE CONTRACTOR DAMAGES A UTILITY, THE CONTRACTOR MUST COMPLETE REPAIRS TO THE DAMAGED UTILITY WITHIN 8 HOURS OF THE DAMAGE. IF A WATER FACILITY IS DAMAGED, THE CONTRACTING OFFICER MUST BE IMMEDIATELY NOTIFIED SO THAT THE GOVERNMENT'S WATER SYSTEM OPERATOR CAN BE CONSULTED AS TO THE CORRECT REPAIR PROCEDURE. AFTER ANY WATER DAMAGE, DISINFECTION AND BACTERIOLOGICAL TESTING MUST BE PERFORMED BY A STATE OF CALIFORNIA CERTIFIED DISTRIBUTION OPERATOR WITH A MINIMUM OF D-1 CERTIFICATION WITHIN 24 HOURS OF THE COMPLETION OF REPAIRS. 2. NEW FENCE LOCATION TO BE IN SAME LOCATION AS EXISTING FENCE EXCEPT IN DRIVEWAY VICINITY. NEW FENCE LOCATION TO BE IN SAME LOCATION AS EXISTING FENCE EXCEPT IN DRIVEWAY VICINITY. REMOVAL OF EXISTING FENCE TO BE COORDINATED WITH INSTALLATION OF NEW FENCE SO THAT SITE IS NOT LEFT UNSECURED AT THE END OF EACH DAY. 3. FENCE POSTS TO BE SET A MINIMUM OF ONE FOOT FROM ROCK/CONCRETE GUTTER. FENCE POSTS TO BE SET A MINIMUM OF ONE FOOT FROM ROCK/CONCRETE GUTTER. 4. ALL EXISTING TREES/BRUSH TO REMAIN. ALL EXISTING TREES/BRUSH TO REMAIN. 5. IF OPTION ITEM FOR AUTOMATIC GATE AND OPERATOR IS AWARDED CONTRACTOR SHALL LOCATE IF OPTION ITEM FOR AUTOMATIC GATE AND OPERATOR IS AWARDED CONTRACTOR SHALL LOCATE OPERATOR, TRENCHING AND ELECTRICAL RUNS IN LOCATION AS DESIGNATED BY THE CONTRACTING OFFICER'S REPRESENTATIVE. LOCATION OF ELECTRICAL METER CONNECTION POINT, JUNCTION BOX AND TRENCHING SHOWN IS APPROXIMATE. EXISTING ROCK/GRAVEL SHALL BE CLEARED FOR A MAXIMUM OF THREE FEET ON EACH SIDE OF TRENCH AND ROCK/GRAVEL TO BE STOCKPILED ON ONE SIDE OF TRENCH AND EXCAVATED SOIL TO BE STOCKPILED ON THE OTHER SIDE ON THE TRENCH AND REUSED FOR BACKFILLING TRENCH. ROCK/GRAVEL SHALL BE PLACED IN ORIGINAL LOCATION AFTER TRENCH IS BACKFILLED. 6. THE ELECTRICAL TRENCH SHALL BE APPROXIMATELY SIX INCHES WIDE AND A MINIMUM TWENTY FOUR THE ELECTRICAL TRENCH SHALL BE APPROXIMATELY SIX INCHES WIDE AND A MINIMUM TWENTY FOUR INCHES DEEP. INSTALL ELECTRICAL CONDUIT IN TRENCH AND BACKFILL SOIL MATERIAL AND COMPACT. ADDITIONAL BACKFILL MATERIAL SHALL BE IMPORTED AND SHALL BE IN ACCORDANCE WITH SECTION 31 20 00, EARTH MOVING GENERAL BACKFILL. ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE NATIONAL ELECTRIC CODE.
AutoCAD SHX Text Version 2.0 12/19/01, FILE: USFS-Dsize(24x36).dwg
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text D
AutoCAD SHX Text F
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text V
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text T
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text M
AutoCAD SHX Text T
AutoCAD SHX Text R
AutoCAD SHX Text A
AutoCAD SHX Text P
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text U
AutoCAD SHX Text T
AutoCAD SHX Text L
AutoCAD SHX Text U
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text G
A
| 1 TITLE PAGE 11X17 |
| Sheets and Views |
| 17X11 |
| 2 CORONA STATION SITE PLAN 11X17 |
| Sheets and Views |
| 17X11 |
| 3 TEMESCAL STATION SITE PLAN 11X17 |
| Sheets and Views |
| 17X11 |
File details come from the government source that posted it. Updated .