ATT_1_SCWA_CAD_standards.pdf

PDF 330 KB Posted

Attached to
On-Call Hydrogeologic Consulting Services
Solicitation number
2024-PURB RFP-0450
Issued by
Sacramento County, San Francisco City, California

About this file

This document is the Computer-Aided Drafting (CAD) Standards manual for the Sacramento County Water Agency (SCWA), including service to the Cities of Elk Grove and Rancho Cordova. The manual provides comprehensive guidelines for consulting engineers and drafting professionals working on SCWA projects, detailing specific requirements for digital drawing file creation, submission, and formatting. The standards cover critical aspects such as drawing file naming conventions, submittal requirements, data transfer protocols, pen settings, text style standards, and a detailed layering convention for various disciplines including civil, architectural, electrical, and landscape elements.

The document specifies that all drawings must be produced using AutoCAD 2020 or later versions and follow precise technical specifications. Digital files can be submitted via USB flash drive or FTP site, and must include all pertinent XREF, .CTB, and image files. The standards emphasize consistency in layer colors, line types, and text styles across different drawing types, with specific instructions for representing existing and new facilities. Consultants are required to strictly adhere to these standards and must discuss any deviations with the CAD manager prior to project initiation. The layering conventions follow typical AIA (American Institute of Architects) layering styles, providing a structured approach to creating and organizing technical drawings for SCWA projects.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Department of Water Resources

Matt Satow, Director Including service to the Cities of

Elk Grove and Rancho Cordova

SACRAMENTO COUNTY

WATER AGENCY

“Managing Tomorrow’s Water Today” Main Office: 827 7th St., Rm. 301, Sacramento, CA 95814 (916) 874-6851 Fax (916) 874-8693 www.scwa.net

Please find enclosed the latest version of the Sacramento County Water Agency’s computer-aided drafting standards. Also included are the plan status submittal requirements (hard copy and electronic) as well as file transfer protocols. Although this office solely uses Autodesk products, these standards herein most likely are applicable to other drafting software used. The Agency requests that all consulting engineers strictly abide by these standards to facilitate the collaboration of any design drawings.

Any deviation from these standards shall be discussed with the CAD manager prior to project initiation.

SCWA Plan Submittal Requirements and Drafting Standards

INDEX

Title Page

Drawing File Naming Conventions Drawing and Specification Submittal Requirements Data Transfer Protocol Pen Settings Text Style Standards Layering Convention

SCWA CAD Standards Revision Date: 8/5/2021

DRAWING FILE NAMING CONVENTIONS

File naming convention to be used for Project Contract Drawings: ??####%%%.dwg

?? #### %%% .dwg

NOTE: The Base Drawings of any set will be named: ??####BS.DWG

(BS = BASE)

EXAMPLE:

Civil drawing number 1 of a project at Dwight Road Facility OWT1 under Contract No.

5445 would be labeled T15445C01.dwg.

1Upon initiation of production drawings the consulting engineer is to contact SCWA for the appropriate

Facility Code. The purpose of the Facility Code is to help identify which major facility the project will be serving.

2 The prefix of the Drawing Number should correlate to the discipline of the drawing (C = Civil, S = Structural, etc)

Facility Code1

Contract Number

Drawing Number2

SCWA CAD Standards Revision Date: 8/5/2021

DRAWING AND SPECIFICATION SUBMITTAL REQUIREMENTS

Unless otherwise specified in the project contract, the consultant is to provide progress drawings (specifications and drawings) at the 20% (A-Plan), 50% (B-Plan) and 90% (C-Plan) stages as well as subsequent Bid Set, Construction Set, and As-Built submittals. In addition to addendums, these submittals shall be provided to SCWA as follows:

20% (A-Plan), 50% (B-Plan) & 90% (C-Plan) Progress Submittals

Specifications:

1 set hard copy unbound single-sided Digital file formatted in Microsoft Word

Drawings:

Provide bound 22”x 34” on bond – contact SCWA for number of copies Provide 1 set of unbound 11”x 17” (50% reduction) on bond Status Stamp: located as shown in Figure 1 Digital CAD files including all pertinent XREF, .CTB and image files PDF files for all sheets

Bid Set Same as the 20 – 90% progress requirements except:

No status stamp Print the cover sheet only on Mylar The cover sheet will not require a progress stamp.

Addendums (provide copies of just those sections / drawings effected) Same as the 20 – 90% progress requirements except:

Provide affected Specifications and drawings on pink paper

Construction Set Same as the 20 – 90% progress requirements except:

No status stamp Remove all addendum symbols from drawings and ensure Specification include any revised sections.

As-Built Drawings Provide Contractor’s record drawings (marked up Construction and Shop

Drawings) Provide 1 set of originals printed on both 11”x 17” & 22”x 34”.

Status Stamp: located as shown in Figure 1

SCWA CAD Standards Revision Date: 8/5/2021

Digital CAD files including all pertinent XREF, .CTB and image files

All design specifications will incorporate existing Agency specifications for new water facilities. All drawings will be produced using AutoCAD 2020 or later version in accordance with the guidelines provided herein.

DATA TRANSFER PROTOCOL

All digital information is to be delivered in either the following manners:

USB Flash Drive FTP Site1

1Consultant is to provide all necessary passwords and usernames upon first status submittal. File structure is to have a logical naming convention based upon the status of the files uploaded.

Figure 1

B-PLANS STATUS SHOWN HERE.

SCWA CAD Standards Revision Date: 8/5/2021

PEN SETTINGS

AUTOCAD PEN/COLOR COLOR PEN WIDTH (IN)

1 RED 7 0.0050 (0.1397 mm) 2 YELLOW 7 0.0070 (0.1778 mm) 3 GREEN 7 0.0160 (0.4064 mm) 4 CYAN 7 0.0195 (0.4953 mm) 5 BLUE 7 0.0210 (0.5334 mm) 6 MAGENTA 7 0.0310 (0.7874 mm) 7 WHITE 7 0.0150 (0.3810 mm) 8 GREY 7 0.0020 (0.0508 mm) 251 251 0.0100 (0.2540 mm)

253 253 0.0100 (0.2540 mm)

Notes:

1. All pens after pen no. 8 will plot in color unless reassigned at user’s discretion.

2. Please provide .CTB files as necessary as specified in the Submittal Requirements.

SCWA CAD Standards Revision Date: 8/5/2021

TEXT STYLE STANDARDS

STYLE PLOTTED HEIGHT FONT LAYER COLOR TEXT WIDTH

L80 0.08” Simplex or Romans 0.007-Red 0.80

L100 0.10” Simplex or Romans 0.010-Yellow 0.80

L120 0.12” Simplex or Romans 0.010-Yellow 0.80

L125 0.125” Simplex or Romans 0.010-Yellow 0.80

L140 0.14” Simplex or Romans 0.012-Green 0.80

L175 0.175” Simplex or Romans 0.014-Cyan 0.80

L200 0.20” Simplex or Romans 0.020-Blue 0.80

L240 0.24” Simplex or Romans 0.020-Blue 0.80

L290 0.29” Simplex or Romans 0.024-Magenta 0.80

L350 0.35” Simplex or Romans 0.024-Magenta 0.80

Notes:

1. Colors should always be by-layer. Layer color refers to recommended color of layer on which text is to be placed.

2. Other .TTF or .SHX files used for logos etc. shall be provided as per Submittal Requirements.

SCWA CAD Standards Revision Date: 8/5/2021

LAYERING CONVENTION

LAYER COLOR LINETYPE DESCRIPTION

A-DOOR 2(yellow) CONTINUOUS DOORS

A-EQPT 2(yellow) CONTINUOUS EQUIPMENT

A-FND 3(green) CONTINUOUS FOUNDATION

A-FURN 1(red) CONTINUOUS FURNITURE

A-GRTE 1(red) CONTINUOUS GRATES

A-HTCH 1(red) CONTINUOUS HATCHING

A-NOTE 2(yellow) CONTINUOUS ARCH. NOTES

A-RAIL 1(red) CONTINUOUS RAILING

A-ROOF-RAL 1(red) CONTINUOUS ROOF RAIL

A-ROOF-FSCA 2(yellow) CONTINUOUS ROOF FASCIA

A-ROOF-JOST 2(yellow) CONTINUOUS ROOF JOIST

A-ROOF-PYWD 1(red) DASHED PLYWOOD ROOFING

A-ROOF-RDGE 1(red) DASHED2 ROOF RIDGE LINE

A-ROOF-STHG 1(red) HIDDEN ROOF SHEATHING

A-ROOF-VLEY 1(red) DASHED2 ROOF VALLEY LINE

A-WALL 3(green) CONTINUOUS WALLS

A-WALL-PART 2(yellow) CONTINUOUS WALL PARTITION

A-WALL-TOP 3(green) CONTINUOUS TOP OF WALL

A-WNDW 2(yellow) CONTINUOUS WINDOW

C-BDRY-CITY 4(cyan) DASHDOT CITY BOUNDARY

C-BDRY-CITY-HTCH 1(red) CONTINUOUS CITY BOUNDARY HATCHING

C-BDRY-CNTY 4(cyan) DASHDOT COUNTY BOUNDARY

C-BOLL 1(red) CONTINUOUS BOLLARD

C-BRNG 2(yellow) CONTINUOUS PL BEARING/DISTANCES

C-BSLN 3(green) CONTINUOUS BASELINE

C-BSLN-STA 3(green) CONTINUOUS BASELINE STATIONING

C-CONC-PAD 3(green) CONTINUOUS CONCRETE PAD

C-CONC-PAD-CONS 1(red) CONTINUOUS CONCRETE PAD CONSTRUCTION

JOINT

C-CONC-PAD-EXPAN 1(red) DASHED CONCRETE PAD EXPANSION JOINT

C-DETL 3(green) CONTINUOUS DETAIL

SCWA CAD Standards Revision Date: 8/5/2021

LAYER COLOR LINETYPE DESCRIPTION

C-DETL-DIM 1(red) CONTINUOUS DETAIL DIMENSIONS

C-DETL-HTCH 1(red) CONTINUOUS DETAIL HATCHING

C-DETL-REBAR 1(red) CONTINUOUS DETAIL REBAR

C-DETL-TEXT 1(red) CONTINUOUS DETAIL TEXT AND DIMENSIONS

C-DETL-TITL 3(green) CONTINUOUS DETAIL TITLE TEXT

C-DIM 1(red) CONTINUOUS DIMENSIONS

C-DRWY-ACCS 2(yellow) DASHED ACCESS PERIMETER DRIVE SPACE

C-EASE-DRAINAGE 2(yellow) DASHED DRAINAGE EASEMENTS

C-EASE-UTILITY 2(yellow) DASHED UTILITY EASEMENTS

C-EASE-SEWER 2(yellow) DASHED SEWER EASEMENTS

C-EASE-WATER 2(yellow) DASHED WATER EASEMENTS

C-ELEV-LIP 1(red) CONTINUOUS LIP ELEVATION

C-ELEV-PAD 1(red) CONTINUOUS PAD ELEVATION

C-ELEV-TBC 1(red) CONTINUOUS TOP BACK OF CURB ELEVATION

C-ELEV-TBW 1(red) CONTINUOUS TOP BACK OF WALK ELEVATION

C-ELEV-SPOT 1(red) CONTINUOUS SPOT ELEVATION

C-ELEV-WALL 1(red) CONTINUOUS WALL ELEVATION

C-FNCE 1(red) DASHED FENCE

C-GRAD-BREAK 1(red) PHANTOM2 GRADE BREAK

C-GRAD-DETL 2(yellow) CONTINUOUS GRADING SPECIFIC DETAIL

C-GRAD-DTCH 2(yellow) DIVIDEX2 GRADING DITCH

C-GRAD-NOTE 2(yellow) CONTINUOUS GRADING NOTES

C-GRAD-RDGE 2(yellow) DASHEDX2 GRADE BREAK OR RIDGE

C-GRAD-SECT 3(green) CONTINUOUS GRADING SECTION

C-GRAD-SLPE 1(red) CONTINUOUS GRADE SLOPE

C-GRAD-SPOT 2(yellow) CONTINUOUS GRADING SPOT ELEVATION

C-GRAD-TEXT 2(yellow) CONTINUOUS GRADING TEXT

C-HTCH 1(red) CONTINUOUS HATCH

C-NRTH 4(cyan) CONTINUOUS NORTH ARROW

C-PRLN 4(cyan) PHANTOM PROPERTY LINE

C-PROF-CONC 3(green) CONTINUOUS PROFILE CONCRETE

C-PROF-ELEV 2(yellow) CONTINUOUS PROFILE GRID ELEVATIONS

C-PROF-GRID 250(grey) CONTINUOUS PROFILE GRID LINES

C-PROF-GRND 2(yellow) CONTINUOUS PROFILE GROUND LINE

SCWA CAD Standards Revision Date: 8/5/2021

LAYER COLOR LINETYPE DESCRIPTION

C-PROF-GRND-HTCH 1(red) CONTINUOUS PROFILE GROUND HATCH

C-PROF-MTLN 4(cyan) PHANTOMX2 PROFILE MATCHLINE

C-PROF-NOTE 3(green) CONTINUOUS PROFILE NOTES

C-PROF-SEWR 2(yellow) CENTER PROFILE SANITARY SEWER

C-PROF-STA 3(green) CONTINUOUS PROFILE STATIONS

C-PROF-STA 3(green) CONTINUOUS PROFILE STATIONS

C-PROF-STRM 2(yellow) CENTER2 PROFILE STORM DRAIN

C-PROF-TEXT 2(yellow) CONTINUOUS PROFILE TEXT

C-PROF-WATR 3(green) CONTINUOUS PROFILE WATER

C-PUMP 3(green) CONTINUOUS BOOSTER PUMP

C-PUMP-PCAN 2(yellow) CONTINUOUS BOOSTER CAN

C-RIVR 1(red) CONTINUOUS RIVER

C-RMVE 2(yellow) CONTINUOUS TO BE REMOVED

C-ROAD-ACDK 2(yellow) CONTINUOUS A.C. DIKE

C-ROAD-BARR 3(green) CONTINUOUS BARRICADE

C-ROAD-CNTR 1(red) CENTER ROAD CL

C-ROAD-EOPV 2(yellow) CONTINUOUS ROAD EDGE OF PAVEMENT

C-ROAD-GRVL 1(red) DASHED GRAVEL ROAD

C-ROAD-GUFL 1(red) CENTER ROAD GUTTER FL

C-ROAD-HWAY 2(yellow) CONTINUOUS HIGHWAY

C-ROAD-HWAYSIGN 1(red) CONTINUOUS HIGHWAY SIGN

C-ROAD-LIP 2(yellow) CONTINUOUS ROAD LIP OF GUTTER

C-ROAD-PRIM 1(red) CONTINUOUS PRIMARY STREET

C-ROAD-PRIM-TEXT 1(red) CONTINUOUS PRIMARY STREET TEXT

C-ROAD-RAMP 1(red) CONTINUOUS ROAD RAMP

C-ROAD-RWLN 3(green) PHANTOM ROAD RIGHT OF WAY

C-ROAD-SCND 1(red) CONTINUOUS SECONDARY STREET

C-ROAD-SCND-TEXT 1(red) CONTINUOUS SECONDARY STREET TEXT

C-ROAD-TBCB 2(yellow) CONTINUOUS ROAD TOP BACK OF CURB

C-ROAD-TBWK 2(yellow) CONTINUOUS ROAD TOP BACK OF SIDEWALK

C-ROAD-TEXT 2(yellow) CONTINUOUS ROAD NAME

C-RRW 1(red) CONTINUOUS RAILROAD RIGHT OF WAY

C-RTN-WALL 2(yellow) CONTINUOUS RETAINING WALL

C-SND-WALL 2(yellow) CONTINUOUS SOUNDWALL

SCWA CAD Standards Revision Date: 8/5/2021

LAYER COLOR LINETYPE DESCRIPTION

C-SECT 4(cyan) PHANTOM SECTION

C-SBL 1(red) PHANTOM SETBACK LINE

C-SEWR-BOAT 3(green) CONTINUOUS SEWER BOAT

C-SEWR-CNTR 2(yellow) CENTER SEWER CL

C-SEWR-CNTR-OFFS 2(yellow) CENTER SEWER CL OFFSITE

C-SEWR-CO 2(yellow) CONTINUOUS SEWER CLEAN OUT

C-SEWR-MH 2(yellow) CONTINUOUS SEWER MANHOLE

C-SEWR-MAIN 3(green) CENTER SEWER MAIN

C-SEWR-SERV 2(yellow) CONTINUOUS SEWER SERVICE

C-SHBD 5(blue) CONTINUOUS BORDER

C-SHBD-APPV 4(cyan) CONTINUOUS APPROVALS

C-SHBD-GRID 8(grey) GRID1 PRIMARY PROFILE GRID

C-SHBD-MTLN 4(cyan) PHANTOMX2 MATCH LINE

C-SHBD-NOTE 3(green) CONTINUOUS SHEET NOTES

C-SHBD-REV1 2(yellow) CONTINUOUS SHEET REVISION 1

C-SHBD-REV2 2(yellow) CONTINUOUS SHEET REVISION 2

C-SHBD-REV3 2(yellow) CONTINUOUS SHEET REVISION 3

C-SHBD-REV4 2(yellow) CONTINUOUS SHEET REVISION 4

C-SHBD-REV5 2(yellow) CONTINUOUS SHEET REVISION 5

C-SHBD-REV6 2(yellow) CONTINUOUS SHEET REVISION 6

C-SHBD-SCWA 2(yellow) CONTINUOUS SCWA LOGO

C-SHBD-SCWA-APPV 2(yellow) CONTINUOUS SCWA APPROVAL

C-SHBD-SCWA-TEXT 2(yellow) CONTINUOUS SCWA TITLE

C-SHBD-STMP 3(green) CONTINUOUS PLAN SET STATUS STAMP

C-SHBD-STMP-11X17 1(red) CONTINUOUS REDUCED PLAN SET STATUS STAMP

C-SHBD-TEXT 3(green) CONTINUOUS BORDER TEXT

C-SHBD-TITL 4(cyan) CONTINUOUS BORDER TITLE

C-SHBD-TRIM 1(red) CONTINUOUS SHEET TRIM LINE

C-SHBD-ZONE 2(yellow) CONTINUOUS SHEET ZONES

C-SITE-APN 1(red) CONTINUOUS ASSESSORS PARCEL NUMBERS

C-SITE-MTLN 4(cyan) PHANTOM2 SITE MATCHLINE

C-SITE-PAVE 2(yellow) CONTINUOUS SITE PAVING

C-SITE-TITLE 4(cyan) CONTINUOUS SITE TITLE

C-SIZE 1(red) CONTINUOUS VALVE SIZE

SCWA CAD Standards Revision Date: 8/5/2021

LAYER COLOR LINETYPE DESCRIPTION

C-SRVY 2(yellow) CONTINUOUS SURVEY RELATED INFORMATION

C-SRVY-BRGS 3(green) CONTINUOUS PROPERTY LINE BEARINGS /

DISTANCES

C-SRVY-BSLN 3(green) CONTINUOUS BASELINE

C-SRVY-EASE 2(yellow) DASHED EASEMENTS LOCATED BY SURVEY

C-SRVY-EOPV 1(red) CONTINUOUS SURVEY EDGE OF PAVEMENT

C-SRVY-MNTS 2(yellow) CONTINUOUS SURVEY MONUMENTS

C-SRVY-NOTE 2(yellow) CONTINUOUS SURVEY RELATED NOTES

C-SRVY-PRLN 3(green) CONTINUOUS SURVEY PROPERTY LINES

C-SRVY-RWLN 2(yellow) CONTINUOUS RIGHT OF WAY

C-SRVY-RWLN-CNTR 1(red) CENTER RIGHT OF WAY CL

C-SRVY-SRFFLT 7(white) CONTINUOUS SURVEY GENERATED TIN

C-SRVY-SRFVIEW 7(white) CONTINUOUS SURVEY GENERATED TIN VIEW

C-SRVY-TOPO-FENCE 1(red) CONTINUOUS SURVEYED FENCE

C-SRVY-TOPO-INDX 2(yellow) CONTINUOUS SURVEY CONTOURS INDEX

C-SRVY-TOPO-INTR 1(red) CONTINUOUS SURVEY CONTOURS INTERMEDIATE

C-SRVY-TOPO-PNTS 1(red) CONTINUOUS SURVEY TOPO POINTS

C-SRVY-TOPO-PNTS-DRWY 1(red) CONTINUOUS SURVEY TOPO DRIVEWAY POINTS

C-SRVY-TOPO-PNTS-LIP 1(red) CONTINUOUS SURVEYED LIP OF GUTTER

C-SRVY-TOPO-PNTS-TBCB 1(red) CONTINUOUS SURVEYED TOP BACK OF CURB

C-SRVY-TOPO-PNTS-TBWK 1(red) CONTINUOUS SURVEYED TOP BACK OF WALK

C-SRVY-TOPO-TEXT 2(yellow) CONTINUOUS SURVEY TOPO TEXT

C-SRVY-TOPO-WALL 1(red) CONTINUOUS SURVEY TOPO POINTS

C-STRM-BOAT 3(green) CONTINUOUS STORM DRAINAGE BOAT

C-STRM-CNTR 1(red) CENTER2 DRAINAGE CL

C-STRM-CNTR-OFFS 1(red) CENTER2 DRAINAGE CL OFFSITE

C-STRM-CULVERT 2(yellow) CONTINUOUS STORM DRAINAGE CULVERT

C-STRM-DI 2(yellow) CONTINUOUS STORM DRAINAGE INLET

C-STRM-MH 2(yellow) CONTINUOUS STORM DRAINAGE MANHOLE

C-STRM-PIPE 3(green) CENTER2 STORM DRAINAGE PIPING

C-STRM-SWALE 2(yellow) CONTINUOUS STORM DRAINAGE SWALE

C-TANK-BWSH 3(green) CONTINUOUS BACKWASH TANK

C-TANK-FUEL 2(yellow) CONTINUOUS FUEL TANK

C-TANK-SCRB 3(green) CONTINUOUS SCRUBBER

SCWA CAD Standards Revision Date: 8/5/2021

LAYER COLOR LINETYPE DESCRIPTION

C-TANK-STOR 3(green) CONTINUOUS STORAGE TANK

C-TANK-STOR-CNTR 1(red) CENTER2 STORAGE TANK CL

C-TANK-STOR-CPAD 1(red) DASHED STORAGE TANK PAD

C-TANK-STOR-RWAL 2(yellow) CONTINUOUS STORAGE TANK RINGWALL

C-TANK-STOR-TEXT 2(yellow) CONTINUOUS STORAGE TANK TEXT

C-TEXT 3(green) CONTINUOUS PLAN SHEET TEXT

C-UTIL-CABL 2(yellow) CENTER2 CABLE TV CL

C-UTIL-FIRE 2(yellow) CENTER2 FIRE CL

C-UTIL-NGAS 2(yellow) CENTER2 NATURAL GAS CL

C-UTIL-TELE 2(yellow) CENTER2 TELEPHONE LINE

C-UTIL-VAULT 2(yellow) CONTINUOUS UTILITY VAULT

C-VESS-FILT 3(green) CONTINUOUS FILTER VESSEL

C-VESS-FILT-CNTR 1(red) CENTER FILTER VESSEL CL

C-VESS-REAC 3(green) CONTINUOUS REACTION VESSEL

C-VESS-REAC-CNTR 1(red) CENTER REACTION VESSEL CL

C-VESS-SCRB 3(green) CONTINUOUS SCRUBBER VESSEL

C-WATR 3(green) HIDDEN BURIED WATER PIPE LINE

C-WATR-ABOVE 3(green) CONTINUOUS ABOVE GROUND WATER PIPE LINE

C-WATR-ABOVE-CNTR 1(red) CENTER2 ABOVE GROUND WATER PIPE CL

C-WATR-ABOVE-CNTR-SYM 1(red) CONTINUOUS ABOVE GROUND WATER PIPE SYMBOL

C-WATR-BO 3(green) CONTINUOUS BLOW OFF

C-WATR-BOAT 3(green) CONTINUOUS BOAT

C-WATR-BW-TANK 3(green) CONTINUOUS BACKWASH TANK

C-WATR-BW-TANK-CNTR 1(red) CENTER2 BACKWASH TANK CL

C-WATR-CNTR 1(red) CENTER2 BURIED WATER PIPE CL

C-WATR-CNTR-SYM 1(red) HIDDEN2 BURIED WATER PIPE SYMBOL

C-WATR-CNTR-OFFS 3(green) CENTER2 BURIED WATER PIPE CL OFFSITE

C-WATR-CNTR-OFFS-SYM 3(green) HIDDEN2 BURIED WATER PIPE OFFSITE SYMBOL

C-WATR-DIP 3(green) HIDDEN BURIED DUCTILE IRON WATER PIPE

C-WATR-DIP-CNTR 1(red) CENTER2 BURIED DUCTILE IRON WATER PIPE

C-WATR-DIP-CNTR-SYM 1(red) HIDDEN2 BURIED D.I. WATER PIPE SYMBOL

C-WATR-FIRE 2(yellow) CONTINOUS FIRE HYDRANT

C-WATR-OFFS 3(green) HIDDEN BURIED WATER PIPE LINE OFFSITE

C-WATR-MAIN 3(green) CONTINUOUS DISTRIBUTION MAIN

SCWA CAD Standards Revision Date: 8/5/2021

LAYER COLOR LINETYPE DESCRIPTION

C-WATR-PCAN 3(green) CONTINUOUS POTABLE BOOSTER PUMP CANS

C-WATR-PCAN-BASE 2(yellow) CONTINUOUS POTABLE BOOSTER PUMP CAN BASE

C-WATR-RAW-BO 2(yellow) CONTINUOUS RAW WATER BLOW OFF

C-WATR-RAW-BOAT 2(yellow) CONTINUOUS RAW WATER BOAT

C-WATR-RAW-MAIN 2(yellow) CONTINUOUS RAW WATER MAIN

C-WATR-RAW-VALVE 2(yellow) CONTINUOUS RAW WATER VALVE

C-WATR-SERV 3(green) CONTINUOUS WATER SERVICE

C-WATR-TBLOCK 2(yellow) CONTINUOUS WATER PIPE THRUST BLOCKS

C-WATR-VALVE 3(green) CONTINUOUS WATER VALVE

C-WATR-VAULT 2(yellow) CONTINUOUS WATER VALVE VAULT

C-WATR-VAULT-LID 1(red) CONTINUOUS WATER VALVE VAULT LID

C-WATR-VAULT-SUMP 1(red) HIDDEN2 WATER VALVE VAULT SUMP

C-WATR-VAULT-SUMP-PMP 2(yellow) CONTINUOUS WATER VALVE VAULT SUMP PUMP

C-WATR-WELL 3(green) CONTINUOUS WATER WELL

DEFPOINTS 7(white) CONTINUOUS [LAYER DOES NOT PLOT]

E-NOTE 3(green) CONTINUOUS ELECTRICAL NOTES

E-POWR-OVER 2(yellow) CONTINUOUS OVERHEAD POWER LINES

E-POWR-UNDR 2(yellow) HIDDENX2 UNDERGROUND ELECTRICAL CABLES

E-ROAD-LIGHT 2(yellow) CONTINUOUS STREET LIGHT

E-CNDT 2(yellow) HIDDEN2 CONDUIT

E-TEXT 2(yellow) CONTINUOUS ELECTRICAL TEXT

E-XFMR 2(yellow) CONTINUOUS ELECTRICAL TRANSFORMER

L-EASE 2(yellow) DASHED LANDSCAPE EASEMENT

REVCLOUD 4(cyan) CONTINUOUS REVISION CLOUD

THESE LAYERING CONVENTIONS FOLLOW TYPICAL AIA LAYERING STYLE. SHOULD NEW

LAYERS NEED TO BE CREATED, PLEASE FOLLOW THIS LAYERING CONVENTION.

FOR EXISTING FACILITIES:

USE LAYERS SHOWN ABOVE WITH AN “X” IN FRONT OF DISCIPLINE. IE: XEPOWEROVER

(DENOTES EXISTING OVERHEAD ELECTRICAL POWER LINES).

File details come from the government source that posted it. Updated .