ATT 1 CIMR Statement of Need.docx
DOCX document 18 KB Posted
- Attached to
- CIMR Units
- Solicitation number
- FA302226Q0304
About this file
This is a Statement of Need for air purification systems required for eight enlisted and officer dormitory buildings (972, 971, 973, 964, 958, 547, 550, and 555) at a Department of the Air Force Air Education and Training Command facility. The requirement addresses mold, fungus, virus, bacteria, and germ elimination to improve air quality and quality of life for occupants while preventing mold growth in living and entertaining quarters, in compliance with AFI 32-6000 Chapter 2 requirements.
The required air purification system must be a single-unit, dedicated device per living unit utilizing Active Air Infusion technology. Each unit must permanently attach to a standard 3-prong 110-120v electrical wall receptacle with a maximum draw of 10 amps, provide coverage up to 500 square feet, and be capable of eliminating contaminants both in the air and on surfaces throughout the coverage area. The related solicitation (FA302226Q0304) corresponds to this need statement and is issued by the Department of the Air Force Air Education and Training Command.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| ATT 2 Provisions and Clauses.pdf | ||
| CIMR Combo.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STATEMENT OF NEED
FOR
Air Purification for UEQ Dorm and UOQ Dormitories Buildings 972, 971,973,964,958,547, 550, and 555
21 Jan 2026
Purpose:
This Statement of Need (SON) defines the scope of equipment specification to provide a need for Air Purification Systems for the Enlisted and Officer Dormitory buildings 972, 971, 973, 964, 958, 547, 550, and 555 to provide better air quality.
Needs / Requirements:
The CIMR Air Purification System eliminates and kills Mold, Fungus, Viruses, Bacteria and Germs in homes and buildings, on surfaces and in the air, anywhere air can reach. These units will give our Officers and Airman a better quality of life while also preventing mold growth throughout the living and entertaining quarters.
This purification system directly meets the requirements of AFI 32-6000 Chapter 2:
2.17.3.3.1. Dry condensation from affected areas.
2.17.3.3.2. Increase air circulation by using a household fan, kitchen vent hood exhaust while cooking, and bathroom exhaust when shower is in use and immediately after use.
2.17.3.3.3. Minimize dust accumulation throughout the unit and clean mildew from visible surfaces using detergent and water or a mild household cleaner, wearing ordinary household rubber gloves.
Product(s) Needed:
1. Air Purification System
1.1. Description of needed air purification system:
1.1.1 Unit must be dedicated to a single living unit (not a multi-room device)
1.1.2 Must permanently attach via a 3-prong 110-120v electrical wall receptacle limited to 10 amps per device.
1.1.3 Unit must cover up to 500 SQ FT.
1.1.4 Unit must be an Active Air Infusion technology that eliminates and kills mold, fungus, viruses, bacteria and germs in homes and buildings, on surfaces and in the air, anywhere air can reach.