Att 08 (DRAFT rcvd 12JUL2023) - Examples of Calibration and Shelf Life Reqs.xlsx

XLSX spreadsheet 23 KB Posted

Attached to
Consequence Management Support Center - DRAFT Solicitation for Industry Day and Synopsis
Solicitation number
W9133L24R3801
Issued by

About this file

This document provides calibration and shelf life management requirements for equipment used by the WMD-CST TDA. It lists 23 items of calibrated equipment along with their National Stock Numbers, shelf life codes, and required calibration intervals ranging from 3 months to 24 months. Requiring agencies include FLIR, Drager, Quest, and Agilent Technologies. Shelf life items include Level A hazmat suits, defibrillator electrode pads, calibration gases, gas sensors, filters, batteries, and internal standards. Shelf life periods are designated as Type I or Type II according to the DOD Shelf Life Management Manual, with expiration requirements and disposal procedures specified. This document establishes critical calibration and replacement schedules to ensure equipment functions satisfactorily for its intended use.

View the file

Other files

File Type Posted
Post CoMSupCen Industry Day -Sol Att 05 - DRAFT PGA (Ver dtd 17NOV2023) (1).pdf PDF
Post CoMSupCen Industry Day Q and A Log.pdf PDF
Post CoMSupCen Industry Day - Revised DRAFT RFP with Tracked Changes (Ver dtd 17NOV2023).pdf PDF
20230808 - Final - CoMSupCen-Industry Day Slides-1.0.pdf PDF
2023-08-08 Industry Day Attendee Roster.pdf PDF
Att 01 (DRAFT dtd 10JUL2023) - CoMSupCen Facility Layout.pdf PDF
Att 15 (DRAFT RFP) - Maintenance History Report.pdf PDF
W9133L24R3801 DRAFT RFP -(Ver dtd 21JUL2023).pdf PDF
Att 09 (DRAFT rcvd 12JUL2023) - Equipment Certifications.xlsx XLSX spreadsheet
Att 10 (DRAFT RFP) - SCA WD 15-4683 Rev 23 (pub. dtd 27DEC2022).pdf PDF
Att 05 (DRAFT dtd 11JUL2023) - GFE_Listing.xlsx XLSX spreadsheet
Att 13 (DRAFT) CoMSupCen SOG-9.0 (Ver dtd 21JUL2023).pdf PDF
Sol Att 01 - DRAFT WDF-Non-Gov Advisor NDA (RFP W9133L24R3801).pdf PDF
Sol Att 04 - DRAFT CoMSupCen RFP Pricing .xlsx XLSX spreadsheet
Sol Att 02- DRAFT Staffing Table (RFP W9133L24R3801).xlsx XLSX spreadsheet
Att 12 (with DRAFT RFP) - CoMSupCen Lease on Bluegrass Station.pdf PDF
Att 06 (DRAFT pulled 27MAY2022) - Form DD200 - FLIPL.pdf PDF
Att 07 (DRAFT rcvd 13JUL2023) - Historical Workload Data.pdf PDF
Att 02 (DRAFT dtd 01JUL2023) - Warehouse Photographs.pdf PDF
Att 04 (DRAFT dtd DEC2022) - Authorized Stockage Level.pdf PDF
Sol Att 03 - DRAFT Past Performance Questionnaire (RFP W9133L24R3801).docx DOCX document
Att 11 (DRAFT) - Request for Travel Authorization (RFTA) Form.pdf PDF
Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Line No.Nomenclature:NSN/MCN/PNShelf Life CodeCalibration or Shelf Life IntervalsNOTES
Calibrated Items List
1Identifinder-NHG5860-01-C03-3516060 monthsC&RS provided by FLIR. Submit 2407 for repair and return thru CoMSupCen or do a D6Z turn-in and requisition another one thru ASL on DA Form 2765.
2Identifinder, Ultra6665-01-C13-9431060 monthsC&RS provided by FLIR. Submit 2407 for repair and return thru CoMSupCen or do a D6Z turn-in and requisition another one thru ASL on DA Form 2765.
3Identifinder 26665-01-T00-224800The advent of new digital technologies eliminates the need for calibration requirements of the Identifinder instruments. This line is for informational purposes only.
4Quantimeter, X-Act 50004230-01-X01-3976012 MonthsC&RS provided by Dräger. Submit 2407 for repair and return thru CoMSupCen or do a D6Z turn-in and requisition another one thru ASL on DA Form 2765. This item replaces the Quantimeter 1000 which is obsolete.
5Test Kit, BG4, RZ-50e4240-01-X01-0900012 MonthsC&RS provided by Dräger. Submit 2407 calibration and/or repair thru CoMSupCen. The only parts of the kit requiring calibration are the AALS flow meter and the manometer.
6Pump, Oxygen Transfer, BG44220-01-C02-5583012 MonthC&RS provided by Dräger. Submit 2407 calibration and/or repair thru CoMSupCen. Air Pressure guages require annual calibration due to the high pressure used within this system.
7Compressor, Cap Diesel Dive Unit4240-01-C07-644503 Months/ QuarterlyUnit requires air quality test to ensure safety of personnel using SCBA units. Take air sample and submit 2407 for testing.
8Monitor, Heat Stress6515-01-C02-5591012 MonthsC&RS provided by Quest. Either submit 2407 for repair and return to CoMSupCen or do a D6Z turn in and requisition another one thru ASL on 2765.
9Multimeter, AN/PSM-456665-01-X01-0778090 DaysC&RS provided by local TMDE support units
10Radiac Set, AN/PDR-75/A, Dosimeter Watch6665-01-602-9991012 MonthsC&RS provided by local TMDE support units
11Reader, Dose, Dosimeter Watch CP-696/A6665-01-601-2569012 MonthsC&RS provided by local TMDE support units
12Radiac Set, AN/PDR-776665-01-347-6100012 MonthsC&RS provided by local TMDE support units
13Radiac Set, AN/UDR-136665-01-4071237012 MonthsC&RS provided by local TMDE support units
14Radiac Set, RGU 1006665-01-627-7915012 MonthsC&RS provided by local TMDE support units
15Radiac Set, AN/VDR-26665-01-222-1425012 MonthsC&RS provided by local TMDE support units
16Flow Meter (ALS)6665-01-X01-0579015 MonthsC&RS provided by Agilent Technologies. Submit 2407 for repair and return thru CoMSupCen.
17Timer, Triple Display (ALS)6640-01-X01-0580024 MonthsDue to cost of replacement versus cost of C&RS, this item is no longer work ordered for calibration or repair. If due Cal or repair, dispose of IAW local policies and requisition a new item.
18Hygrometer/Thermometer (ALS)6685-01-X01-0447024 MonthsDue to cost of replacement versus cost of C&RS, this item is no longer work ordered for calibration or repair. If due Cal or repair, dispose of IAW local policies and requisition a new item.
19Test Set, SCBA, Quaestor 50004240-01-C00-7480012 MonthsC&RS provided by Dräger. Submit 2407 for repair and return thru CoMSupCen or execute a D6Z turn-in and requisition another one thru ASL on DA Form 2765.
20Pipettor, .5~10 µL6665-01-X01-1117015 MonthsC&RS provided by RAININ. Submit 2407 for repair and return thru CoMSupCen, or execute a D6Z turn-in and requisition another one thru ASL on DA Form 2765.
21Pipettor, 2~20 µL6665-01-X01-1574015 MonthsC&RS provided by RAININ. Submit 2407 for repair and return thru CoMSupCen, or execute a D6Z turn-in and requisition another one thru ASL on DA Form 2765.
22Pipettor, 100~1000 µL6665-01-X01-1575015 MonthsC&RS provided by RAININ. Submit 2407 for repair and return thru CoMSupCen, or execute a D6Z turn-in and requisition another one thru ASL on DA Form 2765.
23Pipettor, 10-100 µL6665-01-X01-1576015 MonthsC&RS provided by RAININ. Submit 2407 for repair and return thru CoMSupCen, or execute a D6Z turn-in and requisition another one thru ASL on DA Form 2765.
Shelf Life Management Items
1Suit, Level A, Vapor Total Encapsulating, different vendors and sizes.See CatalogNo Shelf LifeRepairs and services not authorized. If defective D6Z to DRMO and submit AOA requisitition for replacement suit.
2Electrode Pads, Various sizes, Used on Defibrillator and Life Pack 15See CatalogM2 Years Type I Shelf LifeElectrode pads for the defibrillators have a 24 month fixed non-extendable shelf life. Once expired dispose of IAW with local policy. Because the shelf life applies only to the adhesive on the pads, these items may be retained for TRAINING USE ONLY after expiration.
3Gas, Calibration, Hydrogen Cyanide, 10PPM6665-01-X01-1335H12 Months Type I Shelf LifeGas has fixed 12 month non-extendable shelf life. Chemicals react with the metals of the cylinders and will change chemical properties over time. Once expired gas should be disposed of per SDS instructions and state or federal requirements.
4Gas, Calibration, Nitrogen, 100% VOC free. Used with Area Rae and Multi Rae chemical monitors6665-01-X01-1067R48 Months Type I Shelf LifeGas has fixed 48 month non-extendable shelf life. Chemicals react with the metals of the cylinders and will change chemical properties over time. Once expired gas should be disposed of per SDS instructions and state or federal requirements.
5Sensor, Gas, Numerous gas types. Components of Area Rae and Multi Rae chemical monitors.See CatalogH,M12~24 Month Type I Shelf LifeSensors have fixed 12~24 month non-extendable shelf life. Sensors are electro-chemical in nature and will deteriorate over time. Once expired sensors should be disposed of per SDS instructions and state or federal requirements. Gas types sensors can detect include, but are not limited to,: Hydrogen Cyanide (HCN), Chlorine (CL2), Nitrogen Oxide (NO2), Carbon Monoxide (CO), Carbon Dioxide (CO2), Oxygen (O2), Phosgine (PH3) etc...
6Gas, Calibration, Internal Standards, TRIS. Used in the HAPSITE GC/MS6665-01-X01-0700H12 Months Type I Shelf LifeGas has fixed 12 month non-extendable shelf life. Chemicals react with the metals of the cylinders and will change chemical properties over time. Once expired, gas should be disposed of per SDS instructions and state or federal requirements.
7Filter, Gas Particulate4240-01-363-1311 4240-01-X01-4012960 Months Type II Shelf LifeFilter has a 36 month fixed, Type I shelf life due to the carbon absorbant materiels used to manufacture it. The shelf life expiration date continues on after installation in the ALS HEPA filtration system. Once expired, it must be replaced.
8Battery, Non-Rechargable, Lithium Sulfphur Dioxide (LiSO2) BA-5800A/U use with PAPR6135-01-440-7774S60 Month Type I shelf lifeBattery has a 60 Month fixed, type I shelf life. When expired dispose of IAW state and federal requirements for hazardous heavy metal and chemical waste.

The above page of shelf life items is just a small snapshot of the over 250 intensively mangaged items in the warehouse. Most items are classifed as Type I shelf life and must be destroyed or disposed of when expired. Some items are classified as Type II shelf life and can be re-inspected and/or tested to extend the storage life past their expiration/re-inspection dates.

Excerpt of DOD Shelf Life Management Manual 4140.27-M (Appendix E)

Shelf‑Life PeriodType IType IIMonths*Quarters
Non-Deteriorative,0 (zero)0N/AN/A
No Shelf-Life Applies
01 MonthAN/A25 daysN/A
02 MonthsBN/A50 daysN/A
03 MonthsC175 daysN/A
04 MonthsDN/A31
05 MonthsEN/A41
06 MonthsF252
09 MonthsG383
12 Months (1.00-Year)H4103
15 Months (1.25-Years)JN/A134
18 Months (1.50-Years)K5155
21 Months (1.75-Years)LN/A186
24 Months (2.00-Years)M6217
27 Months (2.25-Years)NN/A238
30 Months (2.50-Years)PN/A269
36 Months (3.00-Years)Q73110
48 Months (4.00-Years)R84114
60 Months (5.00-Years)S95117
72 Months (6.00-Years)IN/A6120
84 Months (7.00-Years)TN/A7124
96 Months (8.00-Years)UN/A8227
Variable such as: 90, 132, 216, 228, etc. Months or any other number of months not specifically assigned.VN/A77, 113, 184,194, etc.26, 38, 61,65, etc.
120 Months (10-Years)WN/A10234
180 Months (15-Years)YN/A15351
240 Months (20-Years)ZN/A20468
Shelf‑Life Period Greater than 60 Months for Type II Extendible Items.N/AX85% of number of months remaining85% of number of quarters remaining
Excerpt of DOD Manual 4140.27-M, Page 1-xxv:
Shelf-Life Item. An item of supply possessing deteriorative or unstable characteristics to the degree that a storage time period must be assigned to ensure that it will perform satisfactorily in service. All shelf-life items are classified as one of the following two types:

TYPE I - An individual item of supply, which is determined through an evaluation of technical test data and/or actual experience, to be an item with a definite non-extendible period of shelf-life. One exception is Type I medical shelf-life items (FSC 6505), which may be extended if they have been accepted into and passed testing for extension through the DoD/FDA Shelf-Life Extension Program (SLEP).

TYPE II - An individual item of supply having an assigned shelf-life time period that may be extended after completion of visual inspection/certified laboratory test, and/or restorative action.

*Required Number of Months/Quarters remaining Upon Receipt by the first Government activity

&"Arial,Bold"&12WMD-CST TDA Equipment Calibration and Shelf Life Management Requirements &D image1.png