This document provides calibration and shelf life management requirements for equipment used by the WMD-CST TDA. It lists 23 items of calibrated equipment along with their National Stock Numbers, shelf life codes, and required calibration intervals ranging from 3 months to 24 months. Requiring agencies include FLIR, Drager, Quest, and Agilent Technologies. Shelf life items include Level A hazmat suits, defibrillator electrode pads, calibration gases, gas sensors, filters, batteries, and internal standards. Shelf life periods are designated as Type I or Type II according to the DOD Shelf Life Management Manual, with expiration requirements and disposal procedures specified. This document establishes critical calibration and replacement schedules to ensure equipment functions satisfactorily for its intended use.
View the file
Other files
Show all 22
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
| Line No. | Nomenclature: | NSN/MCN/PN | Shelf Life Code | Calibration or Shelf Life Intervals | NOTES |
| Calibrated Items List | |||||
| 1 | Identifinder-NHG | 5860-01-C03-3516 | 0 | 60 months | C&RS provided by FLIR. Submit 2407 for repair and return thru CoMSupCen or do a D6Z turn-in and requisition another one thru ASL on DA Form 2765. |
| 2 | Identifinder, Ultra | 6665-01-C13-9431 | 0 | 60 months | C&RS provided by FLIR. Submit 2407 for repair and return thru CoMSupCen or do a D6Z turn-in and requisition another one thru ASL on DA Form 2765. |
| 3 | Identifinder 2 | 6665-01-T00-2248 | 0 | 0 | The advent of new digital technologies eliminates the need for calibration requirements of the Identifinder instruments. This line is for informational purposes only. |
| 4 | Quantimeter, X-Act 5000 | 4230-01-X01-3976 | 0 | 12 Months | C&RS provided by Dräger. Submit 2407 for repair and return thru CoMSupCen or do a D6Z turn-in and requisition another one thru ASL on DA Form 2765. This item replaces the Quantimeter 1000 which is obsolete. |
| 5 | Test Kit, BG4, RZ-50e | 4240-01-X01-0900 | 0 | 12 Months | C&RS provided by Dräger. Submit 2407 calibration and/or repair thru CoMSupCen. The only parts of the kit requiring calibration are the AALS flow meter and the manometer. |
| 6 | Pump, Oxygen Transfer, BG4 | 4220-01-C02-5583 | 0 | 12 Month | C&RS provided by Dräger. Submit 2407 calibration and/or repair thru CoMSupCen. Air Pressure guages require annual calibration due to the high pressure used within this system. |
| 7 | Compressor, Cap Diesel Dive Unit | 4240-01-C07-6445 | 0 | 3 Months/ Quarterly | Unit requires air quality test to ensure safety of personnel using SCBA units. Take air sample and submit 2407 for testing. |
| 8 | Monitor, Heat Stress | 6515-01-C02-5591 | 0 | 12 Months | C&RS provided by Quest. Either submit 2407 for repair and return to CoMSupCen or do a D6Z turn in and requisition another one thru ASL on 2765. |
| 9 | Multimeter, AN/PSM-45 | 6665-01-X01-0778 | 0 | 90 Days | C&RS provided by local TMDE support units |
| 10 | Radiac Set, AN/PDR-75/A, Dosimeter Watch | 6665-01-602-9991 | 0 | 12 Months | C&RS provided by local TMDE support units |
| 11 | Reader, Dose, Dosimeter Watch CP-696/A | 6665-01-601-2569 | 0 | 12 Months | C&RS provided by local TMDE support units |
| 12 | Radiac Set, AN/PDR-77 | 6665-01-347-6100 | 0 | 12 Months | C&RS provided by local TMDE support units |
| 13 | Radiac Set, AN/UDR-13 | 6665-01-4071237 | 0 | 12 Months | C&RS provided by local TMDE support units |
| 14 | Radiac Set, RGU 100 | 6665-01-627-7915 | 0 | 12 Months | C&RS provided by local TMDE support units |
| 15 | Radiac Set, AN/VDR-2 | 6665-01-222-1425 | 0 | 12 Months | C&RS provided by local TMDE support units |
| 16 | Flow Meter (ALS) | 6665-01-X01-0579 | 0 | 15 Months | C&RS provided by Agilent Technologies. Submit 2407 for repair and return thru CoMSupCen. |
| 17 | Timer, Triple Display (ALS) | 6640-01-X01-0580 | 0 | 24 Months | Due to cost of replacement versus cost of C&RS, this item is no longer work ordered for calibration or repair. If due Cal or repair, dispose of IAW local policies and requisition a new item. |
| 18 | Hygrometer/Thermometer (ALS) | 6685-01-X01-0447 | 0 | 24 Months | Due to cost of replacement versus cost of C&RS, this item is no longer work ordered for calibration or repair. If due Cal or repair, dispose of IAW local policies and requisition a new item. |
| 19 | Test Set, SCBA, Quaestor 5000 | 4240-01-C00-7480 | 0 | 12 Months | C&RS provided by Dräger. Submit 2407 for repair and return thru CoMSupCen or execute a D6Z turn-in and requisition another one thru ASL on DA Form 2765. |
| 20 | Pipettor, .5~10 µL | 6665-01-X01-1117 | 0 | 15 Months | C&RS provided by RAININ. Submit 2407 for repair and return thru CoMSupCen, or execute a D6Z turn-in and requisition another one thru ASL on DA Form 2765. |
| 21 | Pipettor, 2~20 µL | 6665-01-X01-1574 | 0 | 15 Months | C&RS provided by RAININ. Submit 2407 for repair and return thru CoMSupCen, or execute a D6Z turn-in and requisition another one thru ASL on DA Form 2765. |
| 22 | Pipettor, 100~1000 µL | 6665-01-X01-1575 | 0 | 15 Months | C&RS provided by RAININ. Submit 2407 for repair and return thru CoMSupCen, or execute a D6Z turn-in and requisition another one thru ASL on DA Form 2765. |
| 23 | Pipettor, 10-100 µL | 6665-01-X01-1576 | 0 | 15 Months | C&RS provided by RAININ. Submit 2407 for repair and return thru CoMSupCen, or execute a D6Z turn-in and requisition another one thru ASL on DA Form 2765. |
| Shelf Life Management Items | |||||
| 1 | Suit, Level A, Vapor Total Encapsulating, different vendors and sizes. | See Catalog | No Shelf Life | Repairs and services not authorized. If defective D6Z to DRMO and submit AOA requisitition for replacement suit. | |
| 2 | Electrode Pads, Various sizes, Used on Defibrillator and Life Pack 15 | See Catalog | M | 2 Years Type I Shelf Life | Electrode pads for the defibrillators have a 24 month fixed non-extendable shelf life. Once expired dispose of IAW with local policy. Because the shelf life applies only to the adhesive on the pads, these items may be retained for TRAINING USE ONLY after expiration. |
| 3 | Gas, Calibration, Hydrogen Cyanide, 10PPM | 6665-01-X01-1335 | H | 12 Months Type I Shelf Life | Gas has fixed 12 month non-extendable shelf life. Chemicals react with the metals of the cylinders and will change chemical properties over time. Once expired gas should be disposed of per SDS instructions and state or federal requirements. |
| 4 | Gas, Calibration, Nitrogen, 100% VOC free. Used with Area Rae and Multi Rae chemical monitors | 6665-01-X01-1067 | R | 48 Months Type I Shelf Life | Gas has fixed 48 month non-extendable shelf life. Chemicals react with the metals of the cylinders and will change chemical properties over time. Once expired gas should be disposed of per SDS instructions and state or federal requirements. |
| 5 | Sensor, Gas, Numerous gas types. Components of Area Rae and Multi Rae chemical monitors. | See Catalog | H,M | 12~24 Month Type I Shelf Life | Sensors have fixed 12~24 month non-extendable shelf life. Sensors are electro-chemical in nature and will deteriorate over time. Once expired sensors should be disposed of per SDS instructions and state or federal requirements. Gas types sensors can detect include, but are not limited to,: Hydrogen Cyanide (HCN), Chlorine (CL2), Nitrogen Oxide (NO2), Carbon Monoxide (CO), Carbon Dioxide (CO2), Oxygen (O2), Phosgine (PH3) etc... |
| 6 | Gas, Calibration, Internal Standards, TRIS. Used in the HAPSITE GC/MS | 6665-01-X01-0700 | H | 12 Months Type I Shelf Life | Gas has fixed 12 month non-extendable shelf life. Chemicals react with the metals of the cylinders and will change chemical properties over time. Once expired, gas should be disposed of per SDS instructions and state or federal requirements. |
| 7 | Filter, Gas Particulate | 4240-01-363-1311 4240-01-X01-4012 | 9 | 60 Months Type II Shelf Life | Filter has a 36 month fixed, Type I shelf life due to the carbon absorbant materiels used to manufacture it. The shelf life expiration date continues on after installation in the ALS HEPA filtration system. Once expired, it must be replaced. |
| 8 | Battery, Non-Rechargable, Lithium Sulfphur Dioxide (LiSO2) BA-5800A/U use with PAPR | 6135-01-440-7774 | S | 60 Month Type I shelf life | Battery has a 60 Month fixed, type I shelf life. When expired dispose of IAW state and federal requirements for hazardous heavy metal and chemical waste. |
The above page of shelf life items is just a small snapshot of the over 250 intensively mangaged items in the warehouse. Most items are classifed as Type I shelf life and must be destroyed or disposed of when expired. Some items are classified as Type II shelf life and can be re-inspected and/or tested to extend the storage life past their expiration/re-inspection dates.
Excerpt of DOD Shelf Life Management Manual 4140.27-M (Appendix E)
| Shelf‑Life Period | Type I | Type II | Months* | Quarters |
| Non-Deteriorative, | 0 (zero) | 0 | N/A | N/A |
| No Shelf-Life Applies | ||||
| 01 Month | A | N/A | 25 days | N/A |
| 02 Months | B | N/A | 50 days | N/A |
| 03 Months | C | 1 | 75 days | N/A |
| 04 Months | D | N/A | 3 | 1 |
| 05 Months | E | N/A | 4 | 1 |
| 06 Months | F | 2 | 5 | 2 |
| 09 Months | G | 3 | 8 | 3 |
| 12 Months (1.00-Year) | H | 4 | 10 | 3 |
| 15 Months (1.25-Years) | J | N/A | 13 | 4 |
| 18 Months (1.50-Years) | K | 5 | 15 | 5 |
| 21 Months (1.75-Years) | L | N/A | 18 | 6 |
| 24 Months (2.00-Years) | M | 6 | 21 | 7 |
| 27 Months (2.25-Years) | N | N/A | 23 | 8 |
| 30 Months (2.50-Years) | P | N/A | 26 | 9 |
| 36 Months (3.00-Years) | Q | 7 | 31 | 10 |
| 48 Months (4.00-Years) | R | 8 | 41 | 14 |
| 60 Months (5.00-Years) | S | 9 | 51 | 17 |
| 72 Months (6.00-Years) | I | N/A | 61 | 20 |
| 84 Months (7.00-Years) | T | N/A | 71 | 24 |
| 96 Months (8.00-Years) | U | N/A | 82 | 27 |
| Variable such as: 90, 132, 216, 228, etc. Months or any other number of months not specifically assigned. | V | N/A | 77, 113, 184,194, etc. | 26, 38, 61,65, etc. |
| 120 Months (10-Years) | W | N/A | 102 | 34 |
| 180 Months (15-Years) | Y | N/A | 153 | 51 |
| 240 Months (20-Years) | Z | N/A | 204 | 68 |
| Shelf‑Life Period Greater than 60 Months for Type II Extendible Items. | N/A | X | 85% of number of months remaining | 85% of number of quarters remaining |
| Excerpt of DOD Manual 4140.27-M, Page 1-xxv: | |
| Shelf-Life Item. An item of supply possessing deteriorative or unstable characteristics to the degree that a storage time period must be assigned to ensure that it will perform satisfactorily in service. All shelf-life items are classified as one of the following two types: |
TYPE I - An individual item of supply, which is determined through an evaluation of technical test data and/or actual experience, to be an item with a definite non-extendible period of shelf-life. One exception is Type I medical shelf-life items (FSC 6505), which may be extended if they have been accepted into and passed testing for extension through the DoD/FDA Shelf-Life Extension Program (SLEP).
TYPE II - An individual item of supply having an assigned shelf-life time period that may be extended after completion of visual inspection/certified laboratory test, and/or restorative action.
*Required Number of Months/Quarters remaining Upon Receipt by the first Government activity
&"Arial,Bold"&12WMD-CST TDA Equipment Calibration and Shelf Life Management Requirements &D image1.png