Att 004 - Fire Alarm Reference Materials - Bldgs 7402 _7404.pdf
PDF 5 MB Posted
- Attached to
- Fire Alarm Replacement Federal contract opportunity
- Solicitation number
- W9124823Q0011
About this file
This document provides as-built drawings and inspection reports for fire alarm systems at two child development centers on Fort Campbell, Kentucky. The drawings and reports are for buildings 7402 and 7404 and include floor plans, riser diagrams, and device locations. Inspections found issues such as outdated smoke detectors, corroded sprinkler heads, and batteries failing power tests. The Kingfisher mass notification panel at building 7402 had troubles that were not being monitored. Building 7404 inspections noted dry pendent sprinkler heads over ten years old in need of replacement. The related federal contract opportunity is a solicitation from the Department of the Army Materiel Command Mission and Installation Contracting Command for fire alarm replacement services at an unspecified location. No further details are provided on the opportunity.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Amedment 002_Combined Synopsis Solicitation W9124823Q0011.pdf | ||
| Amedment 001_Combined Synopsis Solicitation W9124823Q0011.pdf | ||
| Att 005 - WD 2015-4675 Rev 20.pdf | ||
| Att 002 - Fire Alarm Inspection Reports - 2900 Block.pdf | ||
| Att 003 - Exit Sign Locations - Bldgs 7402_7404.pdf | ||
| Att 001 - Fire Alarm Layout (Typical) - 2900 Block.pdf | ||
| Combined Synopsis Solicitation W9124823Q0011.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
B R
O W
N
IN
G
C A
M P
B E
L L
N O
N E
File Name:
Sheet Number:
A B C D E F G H
* * * S U P P O R T V A L U E E N G I N E E R I N G - I T P A Y S * * *
A B C D E F G H of Engineers
US Army Corps
* * * S A F E T Y P A Y S * * *
C O
L E
M A
N C
R A
G E
R
W
D Y
D
C Y
P N
F Y
F T
C A
M P
B E
L L
K E
N T
U C
K Y
110Sheet of
M
A R
F001
L E
G E
N D
N O
T
IF
IC
A T
IO
N
P
O T
E C
T
IO
N /M
A S
F
IR
E
A p p r
D a t e
D e s c r ip t io n
R e v is io n s
S y m b o l
D r a w in g c o d e c a le
D a t e
P r o je t n g in e e r
A r c h it e c
D a t e
C h e c k e d b y
D r a w n b y
D e s ig n d b y
C
Y
C O
O K
O
U G
L A
L
M O
N
T
D
A R
C H
IT
E C
G
IN
E E c o n s e n t o f
H r b e r t
In t e r n a t io n a l.
r e p r o d u c e d p h y s ic a ll y o r d ig it a ll w it h o u t t h e e x p r e s s r it t h e s c u m e n m y n o t o p r ie t a r y a n f id e n t ia l:
h o o l
A g e -1
M e d iu m
C h il d D e v e lo p m e n t
C e n te
-B
U
IL
T
VS
P
MIC
FAA
FACP
EVAC
TAMPER DETECTOR
POST INDICATOR VALVE
MASS NOTIFICATION PANEL
FIRE ALARM SPRINKLER BELL
FLOW DETECTOR/SWITCH
FIRE ALARM CONTROL PANEL
SMOKE DETECTOR BASIC
MANUAL STATION-PULL STATION
REM. MIC FOR MASS NOTIFICATION SYSTEM
FIRE ALARM REMOTE ANNUNCIATOR PANEL
MASS NOTIFICATION AND FIRE ALARM STROBES, MOUNTED SIDE BY SIDE
SPEAKER/HORN (ELECTRIC HORN)
SMOKE DETECTOR FOR DUCT
FIRE PROTECTION/MASS NOTIFICATION LEGEND
KITCHEN
TEACHING/DEMO
KITCHEN
STAFF LOUNGE
109A
STORAGE
109B
STAFF TOILET/FIRST AID
COMM
VESTIBULE
ATRIUM 2
ATRIUM 1
GATHERING AREA
HC TOILET
STAFF/PUBLIC/
TRAINING ROOM
CORRIDOR 1
STORAGE
SECURE
COMPUTER LAB
HOMEWORK CENTER
ACTIVITY ROOM 1
GIRLS
BOYS
FRONT DESK
ELEC 2
VESTIBULE
SCALE: 1/8" = 1’-0"
0 16’4’ 8’
JANITOR
C A
M P
B E
L L
B R
O W
N
IN
G
’0
File Name:
Sheet Number:
A B C D E F G H
* * * S U P P O R T V A L U E E N G I N E E R I N G - I T P A Y S * * *
A B C D E F G H of Engineers
US Army Corps
* * * S A F E T Y P A Y S * * *
C O
L E
M A
N C
R A
G E
R
W
D Y
D
C Y
P N
F Y
F T
C A
M P
B E
L L
K E
N T
U C
K Y
110Sheet of
M
A R
FAA
P
P
P
PPP
P
P
VS
V S
V S
V S
V S
V S
V S
V S
VS
V S
VS
VS
VS
V S
VS
VS
VS
VS
VS
V S
VS
V S
V
M
IC
VS
MC
PART "B"
PART "A"
KEY PLAN
F101
P L
A N P
A R
T A
N O
T
IF
IC
A T
IO
N F
L O
O T
E C
T
IO
N /M
A p r
D a t e
D e s c r ip t io n
R e v is io n s
S y m b o l
D r a w in g c o d a le
D a t e
P r o je g in e e r
A r c h it e c t e
C h e c k e d b y
D r a w n b y
D e s ig n
C O
O
U G
L A
M O
N
D
A R
C H
IT
E C
G
IN
E E c o n s e n t r b e r t
In t e r n a t io n a l.
r e p r o d u c e d p h y s ic a ll y o r d ig it a h o u t t h e e x p r e s s it t e c u m e n y n o t o p r ie t a r y a n f id e n t h o o l
A g e -1
M e d iu m
C h il d D e v e lo p m e n t
C e n
-B
U
IL
T
FAA
P
P
P
PPP
P
P
VS
V S
V S
V S
V S
V S
V S
V S
VS
V S
VS
VS
VS
V S
VS
VS
VS
VS
VS
V S
VS
V S
IC
MATCHLINE
MATCHLINE MATCHLINE
MATCHLINE
MC
EF-3
60 60 60
WF
NORTH
SCALE: 1/8"=1’-0"F101
COOLER
WALK-IN
BOYS
GIRLS
ACTIVITY ROOM
PERFORMING ARTS
OFFICE
DIRECTOR’S
F101
FIRE PROTECTION/MASS NOTIFICATION FLOOR PLAN - PART A
STORAGE
DRY FOOD
ELECTRICAL
LAUNDRY
MULTI-PURPOSE
MECHANICAL
MAIN ATRIUM
STORAGE
JANITOR
CORRIDOR
STORAGE AND ISSUE
FEMALE
MALE
VESTIBULE
MONITOR
VIDEO
SCALE: 1/8" = 1’-0"
0 16’4’ 8’
B R
O W
N
IN
G
C A
M P
B E
L L
’0
File Name:
Sheet Number:
A B C D E F G H
* * * S U P P O R T V A L U E E N G I N E E R I N G - I T P A Y S * * *
A B C D E F G H of Engineers
US Army Corps
* * * S A F E T Y P A Y S * * *
C O
L E
M A
N C
R A
G E
R
W
D Y
D
C Y
P N
F Y
F T
C A
M P
B E
L L
K E
N T
U C
K Y
110Sheet of
M
A R
P
FACP
P
P
P
P
P
P
P
P
P
P
P
VS
V S
VS
VS
VS
VS VS
VS
V S
VS
VS
VS
V S
EVAC
PART "B"
PART "A"
KEY PLAN
F102
STORAGE
MULTI-PURPOSE
GIRLS
BOYS
ACTIVITY ROOM
PERFORMING ARTS
ACTIVITY ROOM
ARTS & SCIENCE
COMM
P L
A N P
A R
T B
N O
T
IF
IC
A T
IO
N F
L O
O T
E C
T
IO
N /M
A p r
D a t e
D e s c r ip t io n
R e v is io n s
S y m b o l
D r a w in g c o d a le
D a t e
P r o je g in e e r
A r c h it e c t e
C h e c k e d b y
D r a w n b y
D e s ig n
C O
O
U G
L A
M O
N
D
A R
C H
IT
E C
G
IN
E E c o n s e n t r b e r t
In t e r n a t io n a l.
r e p r o d u c e d p h y s ic a ll y o r d ig it a h o u t t h e e x p r e s s it t e c u m e n y n o t o p r ie t a r y a n f id e n t h o o l
A g e -1
M e d iu m
C h il d D e v e lo p m e n t
C e n
-B
U
IL
T
P
FACP
P
P
P
P
P
P
P
P
P
P
P
VS
V S
VS
VS
VS
VS VS
VS
V S
VS
VS
VS
V S
EVAC
NOTE 1
NOTE 1
NOTE 1NOTE 1
NOTE 1
NOTE 1
MATCHLINE
MATCHLINE MATCHLINE
MATCHLINE
NOTE 2 NOTE 2
PROTECTIVE COVER.
2. INDICATED DEVICES PROVIDE WITH
PROVIDED WITH A WIRE GUARD.
1. INDICATED DEVICES TO BE
NOTES:
M C
AHU-1
M C
AHU-2
MC
RF-1
MC
RF-2
75 75
60 60
30 30
WF
W F
W F
WF
NORTH
SCALE: 1/8"=1’-0"F102F102
FIRE PROTECTION/MASS NOTIFICATION FLOOR PLAN - PART B
O W
N
IN
G
C A
M P
B E
L L
N O
N E
File Name:
Sheet Number:
A B C D E F G H
* * * S U P P O R T V A L U E E N G I N E E R I N G - I T P A Y S * * *
A B C D E F G H of Engineers
US Army Corps
* * * S A F E T Y P A Y S * * *
C O
L E
M A
N C
R A
G E
R
W
D Y
D
C Y
P N
F Y
F T
C A
M P
B E
L L
K E
N T
U C
K Y
110Sheet of
M
A R
1. VERIFY WITH CONTRACTING OFFICER LOCATION OF ANTENNA. PROVIDE LIGHTNING
PROTECTION FOR ANTENNA PER SPECIFICATIONS.
NOTES:
NOTE 2
2. FROM FIRE ALARM SYSTEM CONTROL PANEL FOR NOTIFICATION TO THE MASS
NOTIFICATION SYSTEM CONTROL PANEL THAT SYSTEM ACTIVATION IS ALLOWED.
FIRE ALARM SYSTEM WILL SILENCE ITSELF AND SYNCHRONIZE THE STROBES.
NOTE 3
AFTER THE MASS NOTIFICATION ANNOUNCEMENT IS COMPLETE, THE FIRE ALARM
AUDIBLE SIGNAL SHALL CONTINUE IF THE FIRE ALARM IS STILL IN ALARM.
3. MASS NOTIFICATION AND FIRE ALARM SYSTEMS CONTROL PANELS, ALTHOUGH
INSTALLED IN SEPARATE PANELS, WILL BE A COMBINATION SYSTEM. SYSTEMS WILL
BE NOTHAVE INTEGRATED FUNCTIONS AND WILL SHARE DEVICES. STROBES WILL
SHARED. THE SPEAKERS AND HORNS CONNECTED TO THE MASS NOTIFICATION
SYSTEM WILL ALSO BE USED BY THE FIRE ALARM SYSTEM.
FAA
F601
R
IS
E R
N O
T
IF
IC
A T
IO
O T
E C
T
IO
N /M
A
SCALE: NONEF601 F601
FIRE PROTECTION/MASS NOTIFICATION RISER
A p p r
D a t e
D e s c r ip t io n
R e v is io n s
S y m b o l
D r a w in g c o d a le
D a t e
P r o je g in e e r
A r c h it e c t e
C h e c k e d b y
D r a w n b y
D e s ig n
C O
O
U G
L A
M O
N
D
A R
C H
IT
E C
G
IN
E E c o n s e n t r b e r t
In t e r n a t io n a l.
r e p r o d u c e d p h y s ic a ll y o r d ig it a h o u t t h e e x p r e s s it t e c u m e n y n o t o p r ie t a r y a n f id e n t h o o l
A g e -1
M e d iu m
C h il d D e v e lo p m e n t
C e n
-B
U
IL
T
FINISHED FLOOR
FLOW BELL
WATER
SPRINKLER
BATTERY
CABINET
FACP
MM LVSS
ANTENNA
P
V
V
NOTE 1
C. CONNECT SPRINKLER WATER FLOW BELL PER MANUFACTURER’S REQUIREMENTS
A. KING FISHER RADIO TRANSMITTER IS GOVERNMENT FURNISHED, CONTRACTOR
INSTALLED. COAXIAL CABLE AND CONDUIT WILL BE PROVIDED AND INSTALLED
GENERAL NOTES:
BY CONTRACTOR. VERIFY LOCATION WITH CONTRACTING OFFICER AND FT.
CAMPBELL FIRE DEPARTMENT. VERIFY ZONES WITH FIRE DEPARTMENT.
D. SEE FLOOR PLANS FOR THE NUMBER AND LOCATION OF EQUIPMENT AND
DEVICES.
E. MINIMUM OF #12 AWG GROUNDS WILL BE USED.
CM
TO HVAC
SYSTEM
SHUTOFF
CM
BATTERY
CABINET
F. SEE SHEET E-001 FOR THE SYMBOL LEGEND IDENTIFYING THE MASS NOTIFICATION
SYSTEM DEVICES.
TAMPER
SWITCH
FLOW
SWITCH
TRANSMITTER
RADIO
KING
FISHER
MM MM
G. CIRCUIT BREAKERS FOR THE FACP AND FA RADIO SHALL BE RED AND SHALL BE
PROVIDED WITH A MECHANICAL LOCKING DEVICE. WRITE CIRCUIT NUMBER INSIDE
CONTROL PANEL.
V
MIC
VSVS
TAMPER
SWITCH
AT PIV
EVAC
ABBREVIATIONS:
CM CONTROL MODULE
MM MONITOR MODULE
LA-38
LA-42LA-40 B. NOT USED.
LVSS LOW VOLTAGE SURGE SUPPRESSION
LVSS
LVSS LVSS
X
BATTERY VOLTAGE TYPE:
VDC VDC AH 12
VDC VDC AH 12
VDC VDC AH 12
VDC VDC AH 12
ELEVATOR SYSTEM(S)
SHUNT
BATTERY VOLTAGE TYPE:
VDC VDC AH
VDC VDC AH
1 YEAR -
INSPECTION TYPE
BUILDING NUMBER 2 YEAR -
5 YEAR -
OTHER -
35.0 AMP
MODELRESPONSE TO ALARM MANUFACTURER
AMP
AMP
SWAPPED BATTERY CHARGING LOCATIONLED TESTTRANSMITTER RECEIVES ALARMS FROM FACP TRANSMITTER RECEIVES TROUBLES FROM FACP
NCS
11501 Plantside Drive Suite #4 Louisville, KY 40299
(502) 614-8646
Premier Fire & Security Inc.
1251 N 6th St
Paducah, KY 42002
(270) 443-7060
VDC
MONITORING AGENCY PERSONNEL NOTIFIED
MODEL
CENTERAL DISPATCH 270-798-1221
MONITORING AGENCY
McAuliffe WAY Fort Campbell KY 42223
FIRE ALARM CONTROL PANEL (FACP)
BUILDING POC NAME
PANEL MANUFACTURER
KS, BH, RR
INSPECTION DATES:
27.58
BATTERY CHARGING VOLTAGE
POC CONTACT INFO
NFS2-640
INSPECTION TEAM:
13.84
CIRCUIT BREAKER LOCATION
LOCATION
ELECT ROOM
AMP
FAIL @ 29%
FAIL @ 44%
VDC
15.3
TIME:
NOTIFIER
13.77
DIGITAL ALARM RADIO TRANSMITTER (DART)
VDC 35.0
LAMPS / LED TEST
LOCATION
SECONDARY RECALL RECALL
No Access to smoke in Comm Rm. 131
NOTES, FAILURES AND SYSTEM DEVIATIONS FROM CONTRACT STANDARDS
4 total 12V-35AMP Batteries in FACP/Mass failed the AMP test. Notified COR
FIRE ALARM
PANEL REPORT
VDC
BATTERY CHARGING VOLTAGE
PANEL MANUFACTURER
5/6/2021
RESPONSE TO TROUBLE
ANNUNCIATOR
SPECIAL CONSIDERATIONS - List any unique functions to be aware of before testing
KINGFISHER
MODEL TYPE LOCATION
TIME:
HVAC SHUTDOWN
ELEVATOR RESTART FROM FIRE SYSTEM RESET
KFRI COMBO
RESPONSE TO SUPERVISORY TIME:
PASS
DOOR HOLDERS
HVAC AUTO RESTART FROM FACP RESET
PRIMARY RECALL
IS SYSTEM CONNECTED TO MONITORING AGENCY
13.66 4.45 FAIL @ 13% VDC 35.0 AMP
13.56 5.14 FAIL @ 15% VDC 35.0 AMP
BUILDING 7402-5YR-5-6-2021-NC PAGE 1 OF 10
VDC VDC AH 12
VDC VDC AH 12
BATTERY VOLTAGE TYPE:
VDC VDC AH 12
VDC VDC AH 12
BATTERY VOLTAGE TYPE:
VDC VDC AH 12
VDC VDC AH 12
BATTERY VOLTAGE TYPE:
VDC VDC AH 12
VDC VDC AH 12
BATTERY VOLTAGE TYPE:
VDC VDC AH 12
VDC VDC AH 12
2 YEAR -
BUILDING POC NAME 5 YEAR -
POC CONTACT INFO OTHER -
BUILDING NUMBER 7402 McAuliffe WAY Fort Campbell KY 42223
INSPECTION DATES: INSPECTION TEAM: INSPECTION TYPE
5/6/2021 KS, BH, RR 1 YEAR -
NOTES, FAILURES AND SYSTEM DEVIATIONS FROM CONTRACT STANDARDS
8.3
NOTIFIER FCPS-2458 NAC POWER
BATTERY CHARGING VOLTAGE
27.6 13.62 13.59
9 PASS @ 129%
LOCATION
13.75 9.3
VDC 7.0 AMPPASS @ 133%
LOCATION
20.5
NAC POWER ELECT ROOM
PURPOSE
VDC 18.0 AMPPASS @ 114%
POWER EXPANDER/AUDIO-VISUAL PANEL
MODELPANEL MANUFACTURER PURPOSE
AMP-A2
12.52
PASS
BATTERY CHARGING VOLTAGE
26.25 12.48 24
NOTIFIER DAA-75-25 AMP-BACKUP ELECT ROOM
13.72
LOCATIONPURPOSE
NOTIFIER
PANEL MANUFACTURER MODEL
NOTIFIER FCPS-2458
BATTERY CHARGING VOLTAGE
27.6
POWER EXPANDER/AUDIO-VISUAL PANEL
DAA-75-25 AMP-A3 ELECT ROOM
VDC 18.0 AMP12.46 20.5
12.48
PASS @ 114%
PANEL MANUFACTURER
POWER EXPANDER/AUDIO-VISUAL PANEL
LOCATIONPURPOSEMODEL
AMP12.46 20.5
18.0
POWER EXPANDER/AUDIO-VISUAL PANEL
NOTIFIER
PANEL MANUFACTURER MODEL PURPOSE LOCATION
ELECT ROOM
AMP
AMP
VDC 7.0
VDC
12.49 8.3
8.65 PASS @ 124%
VDC 7.0
ELECT ROOM
VDC 7.0
POWER EXPANDER/AUDIO-VISUAL PANEL
PASS @ 129%
MODEL
BATTERY CHARGING VOLTAGE
26.5
VDC
PASS @ 119% AMP
AMP
VDC AMP7.0
AMP
VDC 18.0
NCS
11501 Plantside Drive Suite #4 Louisville, KY 40299
(502) 614-8646
DAA-75-25
BATTERY CHARGING VOLTAGE
26.25
PANEL MANUFACTURER
Premier Fire & Security Inc.
1251 N 6th St
Paducah, KY 42002
(270) 443-7060
AUXILIARY
PANEL REPORT
7.0
PASS @ 133%
PASS @ 114%
PASS
PASS
PASS
PASS
PASS @ 119%
BUILDING 7402-5YR-5-6-2021-NC PAGE 2 OF 10
VDC VDC AH 12
VDC VDC AH 12
BATTERY VOLTAGE TYPE:
VDC VDC AH
VDC VDC AH
BATTERY VOLTAGE TYPE:
VDC VDC AH
VDC VDC AH
BATTERY VOLTAGE TYPE:
VDC VDC AH
VDC VDC AH
BATTERY VOLTAGE TYPE:
VDC VDC AH
VDC VDC AH
NCS
11501 Plantside Drive Suite #4 Louisville, KY 40299
(502) 614-8646
AUXILIARY
PANEL REPORT
Premier Fire & Security Inc.
1251 N 6th St
Paducah, KY 42002
(270) 443-7060
INSPECTION DATES: INSPECTION TEAM: INSPECTION TYPE
5/6/2021 KS, BH, RR 1 YEAR -
BUILDING NUMBER 7402 McAuliffe WAY Fort Campbell KY 42223 2 YEAR -
NAC POWER ELECT ROOM
BUILDING POC NAME 5 YEAR -
POC CONTACT INFO OTHER -
VDC 7.0 AMP
POWER EXPANDER/AUDIO-VISUAL PANEL
PANEL MANUFACTURER MODEL PURPOSE LOCATION
NOTIFIER FCPS-2458
7.3 PASS @ 104% VDC
BATTERY CHARGING VOLTAGE
27.5 PASS 13.5 7.3 PASS @ 104%
7.0 AMP
POWER EXPANDER/AUDIO-VISUAL PANEL
PANEL MANUFACTURER MODEL PURPOSE LOCATION
13.47
BATTERY CHARGING VOLTAGE
VDC AMP
VDC AMP
POWER EXPANDER/AUDIO-VISUAL PANEL
PANEL MANUFACTURER MODEL PURPOSE LOCATION
BATTERY CHARGING VOLTAGE
VDC AMP
VDC AMP
POWER EXPANDER/AUDIO-VISUAL PANEL
PANEL MANUFACTURER MODEL PURPOSE LOCATION
BATTERY CHARGING VOLTAGE
VDC AMP
VDC AMP
POWER EXPANDER/AUDIO-VISUAL PANEL
PANEL MANUFACTURER MODEL PURPOSE LOCATION
BATTERY CHARGING VOLTAGE
VDC AMP
VDC AMP
NOTES, FAILURES AND SYSTEM DEVIATIONS FROM CONTRACT STANDARDS
BUILDING 7402-5YR-5-6-2021-NC PAGE 3 OF 10
NCS
11501 Plantside Drive Suite #4 Louisville, KY 40299
(502) 614-8646
Premier Fire & Security Inc.
1251 N 6th St
Paducah, KY 42002
(270) 443-7060
DATE
5/6/2021
DEVICE DEVICE LOCATION DEVICE
ADDRESS
OR
ZONE
P A
SS
FA
IL
Se ns iti vi ty
NOTES:
FA MECHANIC ROOM P
KF MECHANIC ROOM P
BPS MECHANIC ROOM P
BPS MECHANIC ROOM P
BPS MECHANIC ROOM P
BPS MECHANIC ROOM P
BPS MECHANIC ROOM P
VN MECHANIC ROOM WITH FACP P
HS MECHANIC ROOM WITH FACP P
VN MECHANIC ROOM WITH SPRINKLER P
VN MECHANIC ROOM WITH SPRINKLER P
HS MECHANIC ROOM WITH SPRINKLER P
HS MECHANIC ROOM WITH SPRINKLER P
VN OUTSIDE MECHANIC ROOM WITH
SPRINKLER
P
VN OUTSIDE MECHANIC ROOM WITH
SPRINKLER
P
HS OUTSIDE MECHANIC ROOM WITH
SPRINKLER
P
HS OUTSIDE MECHANIC ROOM WITH
SPRINKLER
P
AB OUTSIDE MECHANIC ROOM WITH
SPRINKLER
P
VN OUTSIDE LEFT OF ENTRANCE P
HS OUTSIDE LEFT OF ENTRANCE P
VN OUTSIDE BY MAIN DR P
HS OUTSIDE BY MAIN DR P
VN PLAYGROUND AREA OUTSIDE P
VN PLAYGROUND AREA OUTSIDE P
HS PLAYGROUND AREA OUTSIDE P
HS PLAYGROUND AREA OUTSIDE P
HS PLAYGROUND AREA OUTSIDE P
VN FRONT EXIT P
AN FRONT EXIT P
AN FRONT DESK AREA P
FA = FIRE ALARM - KF = KINGFISHER - BPS = BOOSTER POWER SUPPLY - VP=VOICE/MASS PANEL - AN=ANNUNCIATOR/MASS CONSOLE - PS=MANUAL PULL - SD=SMOKE DETECTOR - DD=DUCT DETECTOR - HD = HEAT DETECTOR - MM=MONITOR MODULE - CR=CONTROL RELAY - CM=CONTROL MODULE - HS = HORN/STROBE - S=STROBE ONLY - MS=MASS STROBE - SPK=SPEAKER - DH=DOOR HOLDER
BUILDING NUMBERINSPECTION TEAM
KS, BH, RR 7402
FIRE ALARM
DEVICE REPORT
BUILDING 7402-5YR-5-6-2021-NC PAGE 4 OF 10
Suite #4 Louisville, KY 40299
(502) 614-8646
Premier Fire & Security Inc.
1251 N 6th St
Paducah, KY 42002
(270) 443-7060
DATE
5/6/2021
DEVICE DEVICE LOCATION DEVICE
ADDRESS
OR
ZONE
P A
SS
FA
IL
Se ns iti vi ty
NOTES:
FA = FIRE ALARM - KF = KINGFISHER - BPS = BOOSTER POWER SUPPLY - VP=VOICE/MASS PANEL - AN=ANNUNCIATOR/MASS CONSOLE - PS=MANUAL PULL - SD=SMOKE DETECTOR - DD=DUCT DETECTOR - HD = HEAT DETECTOR - MM=MONITOR MODULE - CR=CONTROL RELAY - CM=CONTROL MODULE - HS = HORN/STROBE - S=STROBE ONLY - MS=MASS STROBE - SPK=SPEAKER - DH=DOOR HOLDER
BUILDING NUMBERINSPECTION TEAM
KS, BH, RR 7402
FIRE ALARM
DEVICE REPORT
AN FRONT DESK AREA P
VN FRONT DESK AREA P
HS FRONT DESK AREA P
VN CAFETERIA AREA P
HS CAFETERIA AREA P
VN KITCHEN P
HS KITCHEN P
HS CAFETERIA AREA P
VN CAFETERIA AREA P
HS BOYS ROOM P
VN BOYS ROOM P
HS GIRLS ROOM P
VN GIRLS ROOM P
HS STORAGE ROOM 117 P
VN STORAGE ROOM 117 P
VN COMMON AREA P
HS COMMON AREA P
VN COMMON AREA P
VN COMMON AREA P
VN COMMON AREA P
VN GYM P
VN GYM P
HS GYM P
HS GYM P
HS ROOM 120 P
VN ROOM 120 P
VN OUTSIDE BACK WALL P
VN OUTSIDE BACK WALL P
HS OUTSIDE BACK WALL P
HS OUTSIDE BACK WALL P
BUILDING 7402-5YR-5-6-2021-NC PAGE 5 OF 10
Suite #4 Louisville, KY 40299
(502) 614-8646
Premier Fire & Security Inc.
1251 N 6th St
Paducah, KY 42002
(270) 443-7060
DATE
5/6/2021
DEVICE DEVICE LOCATION DEVICE
ADDRESS
OR
ZONE
P A
SS
FA
IL
Se ns iti vi ty
NOTES:
FA = FIRE ALARM - KF = KINGFISHER - BPS = BOOSTER POWER SUPPLY - VP=VOICE/MASS PANEL - AN=ANNUNCIATOR/MASS CONSOLE - PS=MANUAL PULL - SD=SMOKE DETECTOR - DD=DUCT DETECTOR - HD = HEAT DETECTOR - MM=MONITOR MODULE - CR=CONTROL RELAY - CM=CONTROL MODULE - HS = HORN/STROBE - S=STROBE ONLY - MS=MASS STROBE - SPK=SPEAKER - DH=DOOR HOLDER
BUILDING NUMBERINSPECTION TEAM
KS, BH, RR 7402
FIRE ALARM
DEVICE REPORT
VN ROOM 125 P
HS ROOM 125 P
VN OUTSIDE GYM BATHROOM P
HS OUTSIDE GYM BATHROOM P
H BOYS ROOM P
VN BOYS ROOM P
H GIRLS ROOM P
VN GIRLS ROOM P
VN ROOM 129 P
HS ROOM 129 P
VN ROOM 130 P
HS ROOM 130 P
VN REC ROOM AREA P
VN REC ROOM AREA P
HS REC ROOM AREA P
HS REC ROOM AREA P
VN ROOM 131 P
HS ROOM 131 P
VN OUTSIDE FOYER P
VN BOYS ROOM REC. AREA P
HS BOYS ROOM REC. AREA P
VN GIRLS ROOM REC AREA P
HS GIRLS ROOM REC AREA P
VN ROOM 136 P
HS ROOM 136 P
VN ROOM 137 P
HS ROOM 137 P
VN ROOM 138 P
HS ROOM 138 P
VN ROOM 104 P
BUILDING 7402-5YR-5-6-2021-NC PAGE 6 OF 10
Suite #4 Louisville, KY 40299
(502) 614-8646
Premier Fire & Security Inc.
1251 N 6th St
Paducah, KY 42002
(270) 443-7060
DATE
5/6/2021
DEVICE DEVICE LOCATION DEVICE
ADDRESS
OR
ZONE
P A
SS
FA
IL
Se ns iti vi ty
NOTES:
FA = FIRE ALARM - KF = KINGFISHER - BPS = BOOSTER POWER SUPPLY - VP=VOICE/MASS PANEL - AN=ANNUNCIATOR/MASS CONSOLE - PS=MANUAL PULL - SD=SMOKE DETECTOR - DD=DUCT DETECTOR - HD = HEAT DETECTOR - MM=MONITOR MODULE - CR=CONTROL RELAY - CM=CONTROL MODULE - HS = HORN/STROBE - S=STROBE ONLY - MS=MASS STROBE - SPK=SPEAKER - DH=DOOR HOLDER
BUILDING NUMBERINSPECTION TEAM
KS, BH, RR 7402
FIRE ALARM
DEVICE REPORT
HS ROOM 104 P
VN ROOM 109A P
HS ROOM 109A P
VN RESTROOM NEAR FRONT DESK P
HS RESTROOM NEAR FRONT DESK P
VN ROOM 102 P
HS ROOM 102 P
SD Main Electrical Rm. 122 D-1 P 3.07 LEVELS ARE 0.5 TO 3.71 SD Multi-Purpose Stor. Rm. 120 D-2 P 2.27
DD AHU-2 Return D-3 P 2.4
DD AHU-1 Return D-4 P 2.54
HD Mechanical Rm. 119 D-5 P
HD Mechanical Rm. 119 D-6 P
SD Video Monitor Rm. 118 D-7 P 2.37
SD Storage Rm. 117 D-8 P 2.55
SD Girls Restroom Rm. 109 D-9 P 2.39
SD Boys Restroom Rm. 115 D-10 P 2.5
HD Kitchen Rm. 113 D-11 P
HD Kitchen Rm. 113 D-13 P
SD Dry Food Storage Rm. 112 D-14 P 2.84
SD Atrium-1 Rm. 114 D-15 P 2.5
SD Atrium-1 Rm. 114 D-16 P 2.52
SD Staff Lounge Rm. 109A D-17 P 2.44
SD Closet Rm. 105 D-18 P 2.24
SD Staff Toilet Rm. 107 D-19 P 2.56
SD Staff/Pòblic Toilet Rm. 108 D-20 P 2.34
SD Training Rm. 104 D-21 P 2.32
SD Front Desk Rm . 106 D-22 P 2.48
SD Director's Office Rm. 102 D-23 P 3.32
SD Corridor-1 Rm. 103 D-24 P 2.54
BUILDING 7402-5YR-5-6-2021-NC PAGE 7 OF 10
Suite #4 Louisville, KY 40299
(502) 614-8646
Premier Fire & Security Inc.
1251 N 6th St
Paducah, KY 42002
(270) 443-7060
DATE
5/6/2021
DEVICE DEVICE LOCATION DEVICE
ADDRESS
OR
ZONE
P A
SS
FA
IL
Se ns iti vi ty
NOTES:
FA = FIRE ALARM - KF = KINGFISHER - BPS = BOOSTER POWER SUPPLY - VP=VOICE/MASS PANEL - AN=ANNUNCIATOR/MASS CONSOLE - PS=MANUAL PULL - SD=SMOKE DETECTOR - DD=DUCT DETECTOR - HD = HEAT DETECTOR - MM=MONITOR MODULE - CR=CONTROL RELAY - CM=CONTROL MODULE - HS = HORN/STROBE - S=STROBE ONLY - MS=MASS STROBE - SPK=SPEAKER - DH=DOOR HOLDER
BUILDING NUMBERINSPECTION TEAM
KS, BH, RR 7402
FIRE ALARM
DEVICE REPORT
SD Vestibule Rm. 101 D-25 P 2.53
SD Computer Lab Rm. 136 D-26 P 2.58
SD Homework Rm. 137 D-27 P 2.58
SD Activity Rm. 136 D-28 P 3.1
SD Girls Restroom Rm. 134 D-29 P 3.07
SD Boys Restroom Rm. 133 D-30 P 3.1
SD Atrium-2 Rm. 135 D-31 P 2.7
SD Atrium-2 Rm. 135 D-32 P 2.73
SD Gathering Area Rm. 141 D-33 P 3.05
SD Main Atrium Rm. 140 D-34 P 2.47
SD Arts/Science/Activ. Rm. 129 D-35 P 2.5
SD Performing Arts Rm. 130 D-36 P 2.36
Comm. Room Rm. 131 D-37 NO ACCESS TO SMOKE SD Vestibule Rm. 132 D-38 P 2.88
SD Female Restroom Rm. 127 D-39 P 2.44
SD Male Restroom Rm. 128 D-40 P 2.05
SD Corridor 126 D-41 P 2.86
SD Storage/Issue Rm. 125 D-42 P 2.45
SD Multi-Purpose Rm. 124 D-44 P
SD Multi-Purpose # Rm. 124 D-45 P
SD Multi-Purpose Rm. 124 D-46 P
SD Multi-Purpose Rm. 124 D-47 P
DD AHU-1 Supply D-49 P 2.39
DD AHU-2 Supply D-50 P 2.51
SD Main Atrium Rm. 140 D-51 P 3.01
SD Storage Closet Rm. 136 D-52 P 2.44
SD Janitor Closet Rm. 121 D-53 P 2.9
SD Laundry Rm. 123 D-54 P 2.49
PS Main Electrical Rm. 122 M-1 P
PS Multi-Purpose Stor. Rm. 120 M-2 P
BUILDING 7402-5YR-5-6-2021-NC PAGE 8 OF 10
Suite #4 Louisville, KY 40299
(502) 614-8646
Premier Fire & Security Inc.
1251 N 6th St
Paducah, KY 42002
(270) 443-7060
DATE
5/6/2021
DEVICE DEVICE LOCATION DEVICE
ADDRESS
OR
ZONE
P A
SS
FA
IL
Se ns iti vi ty
NOTES:
FA = FIRE ALARM - KF = KINGFISHER - BPS = BOOSTER POWER SUPPLY - VP=VOICE/MASS PANEL - AN=ANNUNCIATOR/MASS CONSOLE - PS=MANUAL PULL - SD=SMOKE DETECTOR - DD=DUCT DETECTOR - HD = HEAT DETECTOR - MM=MONITOR MODULE - CR=CONTROL RELAY - CM=CONTROL MODULE - HS = HORN/STROBE - S=STROBE ONLY - MS=MASS STROBE - SPK=SPEAKER - DH=DOOR HOLDER
BUILDING NUMBERINSPECTION TEAM
KS, BH, RR 7402
FIRE ALARM
DEVICE REPORT
PS Mechanical Rm. 119 M-3 P
CR AHU-1 Shutdown M-4 P
PS Kitchen Rm. 113 M-6 P
MM Kitchen Hood ANSUL Rm. 113 M-7 P
PS Vestibule Rm. 101 M-10 P
PS Computer Lab Rm. 136 M-11 P
PS Homework Rm. 137 M-12 P
PS Activity-1 Rm. 136 M-13 P
PS Vestibule Rm. 132 M-14 P
PS Performing Arts Rm. 130 M-15 P
PS Arts/Science/Act. Rm. 129 M-16 P
PS Corridor 126 M-17 P
PS Storage/Issue RM. 125 M-18 P
PS Storage/Issue Rm. 125 M-19 P
PS Multi-Purpose Rm. 124 M-20 P
PS Multi-Purpose Rm. 124 M-21 P
WF Sprinkler Riser M-24 P
TS Sprinkler Riser M-25 P
TS PIV M-26 P
PS Atrium-1 Rm. 114 M-27 P
CR AHU-2 Shutdown M-28 P
MM Battery Charger M-30 P
PIV P
VP P
AN P
AN P
WA P
WPSR P
FDC P
INSPTEST P
BUILDING 7402-5YR-5-6-2021-NC PAGE 9 OF 10
Sprinkler System Inspection
X
Yes No N/A Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A Yes No N/A
MECH ROOM 4" CHECK 717RVICTAULIC
4. Wet Systems 5 Year Wet:
Is System in operation?
Dry Pendent head in cooler is past its 10 year date, needs replaced - Standard Response 155DG Janitor 121 - 1/2" - 155dg quick Response pendent head is painted.
MAKE
Is air pressure on the system satisfactory?
satisfactory operating condition?
Did system trip by device to verify operation?
Does quick opening devices work properly?
Did system trip by manual actuator?
MODEL NUMBER
BUILDING NUMBER
Verify water supply "conduct main drain test"
Gauges appear to be in working order ?
2.Annual, 2 Year and 5 Year Inspections:
Gauges are 2010 - past their certificaiton date 2 total
POC CONTACT INFO
BUILDING POC NAME
VALVE SIZE AND TYPE
NOTES, FAILURES AND SYSTEM DEVIATIONS FROM CONTRACT STANDARDS
Does low air supply works properly?
1.All Inspections:
INSPECTION DATES:
5/6/2021
Adequate heating, and on if necessary.
KS, BH, RR
INSPECTION TEAM:
Is hydrolic nameplace present and visible?
Are control valves supervised, lock or Tamper?
VALVE LOCATION
All low points drained?
All low points drained?
Are OS&Y stems lubricated?
All strainers cleaned and in proper condition.Operated valve to verify proper function?
Verified water travels through inspectors test.
Street:
and filled with the correct sprinkler heads?
Is sprinkler head cabinet mounted close to the riser
Are all control valves and trim in good condition?
5. Dry Pipe Bi-Annual
Trip valve, drain and clean internally Does quick opening devices work properly?
Anti-freeze loops have correct solution mixture.
Does low air supply works properly?
Premier Fire & Security Inc.
1251 N 6th St
Paducah, KY 42002
(270) 443-7060
NCS
11501 Plantside Drive Suite #4 Louisville, KY 40299
(502) 614-8646
SPECIAL CONSIDERATIONS - List any unique functions to be aware of prior to testing
Are fire department caps in good condition?
Alarm test in proper position.
Does water flow devices work properly?
Is fire department connection accessible?
3. 2 Year and 5 Year Inspections:
Internally inspected, cleaned and free from damage?
Is air compressor in service and in
Residule:
Static:
OTHER -
Residule: 55 System: 60
5 YEAR -
2 YEAR -7402
Hydrostatic or Previous Gauge Readings
Is there a Backflow Device at the riser?
Current Gauge Readings Street: 80
ANNUAL -
INSPECTION TYPE
5. Dry Pipe and Pre-action 5 Year
6. Pre-action Bi-Annual
SYSTEM TYPE
OTHER -
PRE-ACTION -
DRY PIPE -
WET PIPE -
McAuliffe WAY Fort Campbell KY 42223
80 Static:System:
Air: Air:Pilot:Pilot:
BUILDING 7402-5YR-5-6-2021-NC PAGE 10 OF 10
VDC VDC AH 12
VDC VDC AH 12
ELEVATOR SYSTEM(S)
SHUNT
BATTERY VOLTAGE TYPE:
VDC VDC AH
VDC VDC AH
PASS
DOOR HOLDERS
HVAC AUTO RESTART FROM FACP RESET PASS
PASS
PRIMARY RECALL
IS SYSTEM CONNECTED TO MONITORING AGENCY
RESPONSE TO SUPERVISORY TIME:
ELEVATOR RESTART FROM FIRE SYSTEM RESET
KFRI COMBO
PASS
ANNUNCIATOR
SPECIAL CONSIDERATIONS - List any unique functions to be aware of before testing
KINGFISHER
MODEL TYPE LOCATION
FAIL
TIME:
HVAC SHUTDOWN
FIRE ALARM
PANEL REPORT
VDC
BATTERY CHARGING VOLTAGE
PANEL MANUFACTURER
12:47pm
5/10/2021
RESPONSE TO TROUBLE
NO ACCESS TO SMOKE IN COMM ROOM 141
NOTES, FAILURES AND SYSTEM DEVIATIONS FROM CONTRACT STANDARDS
THE KINGFISHER.
2 TROUBLES ON PANEL UPON ARRIVAL, BOTH FOR MISSING LCD ANN CARDS. THE OCCUPANTS SAID DPW IS WORKING AND HAD TO ORDER PARTS. ALSO THE TROUBLES ARE NOT BEING MONITORED BY
27.5
TIME:
SIMPLEX
13.54
DIGITAL ALARM RADIO TRANSMITTER (DART)
VDC 35.0
LAMPS / LED TEST
LOCATION
SECONDARY RECALL RECALL
13.63
CIRCUIT BREAKER LOCATION
LOCATION
ELECT ROOM
AMP
PASS @ 72%
PASS @ 79%
VDC
INSPECTION DATES:
27.25
BATTERY CHARGING VOLTAGE
POC CONTACT INFO
25.25
4100UD
INSPECTION TEAM:
JOSH
MODEL
CENTERAL DISPATCH 270-798-1221
MONITORING AGENCY
McAuliffe WAY Fort Campbell KY 42223
FIRE ALARM CONTROL PANEL (FACP)
BUILDING POC NAME
PANEL MANUFACTURER
KS, AS, RR
NCS
11501 Plantside Drive Suite #4 Louisville, KY 40299
(502) 614-8646
Premier Fire & Security Inc.
1251 N 6th St
Paducah, KY 42002
(270) 443-7060
VDC
MONITORING AGENCY PERSONNEL NOTIFIED
SWAPPED BATTERY CHARGING LOCATIONLED TESTTRANSMITTER RECEIVES ALARMS FROM FACP TRANSMITTER RECEIVES TROUBLES FROM FACP
MODELRESPONSE TO ALARM MANUFACTURER
AMP
AMP
1 YEAR -
INSPECTION TYPE
PASS
BUILDING NUMBER 2 YEAR -
5 YEAR -
OTHER -
35.0 AMP
BUILDING 7404-5YR-5-10-2021 PAGE 1 OF 9
VDC VDC AH 12
VDC VDC AH 12
BATTERY VOLTAGE TYPE:
VDC VDC AH 12
VDC VDC AH 12
BATTERY VOLTAGE TYPE:
VDC VDC AH
VDC VDC AH
BATTERY VOLTAGE TYPE:
VDC VDC AH
VDC VDC AH
BATTERY VOLTAGE TYPE:
VDC VDC AH
VDC VDC AH
PASS
PASS @ 73%
NCS
11501 Plantside Drive Suite #4 Louisville, KY 40299
(502) 614-8646
BATTERY CHARGING VOLTAGE
27.6
PANEL MANUFACTURER
Premier Fire & Security Inc.
1251 N 6th St
Paducah, KY 42002
(270) 443-7060
AUXILIARY
PANEL REPORT
7.0
FAIL @ 5%
FAIL @ 0%
VDC
AMP
AMP
VDC AMP
AMP
VDC 7.0
VDC
VDC
POWER EXPANDER/AUDIO-VISUAL PANEL
MODEL
BATTERY CHARGING VOLTAGE
AMP
AMP
VDC 7.0
VDC
13.54 5.14
6.07 PASS @ 87%
13.59 0.00 7.0
POWER EXPANDER/AUDIO-VISUAL PANEL
SIMPLEX
PANEL MANUFACTURER MODEL PURPOSE LOCATION
ELECT ROOM
PANEL MANUFACTURER
POWER EXPANDER/AUDIO-VISUAL PANEL
LOCATIONPURPOSEMODEL
AMP
VDC AMP
PANEL MANUFACTURER MODEL
BATTERY CHARGING VOLTAGE
POWER EXPANDER/AUDIO-VISUAL PANEL
ELECT ROOM
2 total 12v-7amp batteries failed in booster panel inside building in elect room 153. notified COR
LOCATIONPURPOSE
BATTERY CHARGING VOLTAGE
27.5 13.65 0.33
SIMPLEX 4009 NAC POWER
MODELPANEL MANUFACTURER PURPOSE
NAC POWER
13.56
PASS
LOCATION
PURPOSE
VDC AMP
POWER EXPANDER/AUDIO-VISUAL PANEL
LOCATION
VDC AMP
NOTES, FAILURES AND SYSTEM DEVIATIONS FROM CONTRACT STANDARDS
BATTERY CHARGING VOLTAGE
INSPECTION DATES: INSPECTION TEAM: INSPECTION TYPE
5/10/2021 KS, AS, RR 1 YEAR -
2 YEAR -
BUILDING POC NAME 5 YEAR -
POC CONTACT INFO OTHER -
BUILDING NUMBER 7404 McAuliffe WAY Fort Campbell KY 42223
BUILDING 7404-5YR-5-10-2021 PAGE 2 OF 9
Suite #4 Louisville, KY 40299
(502) 614-8646
Premier Fire & Security Inc.
1251 N 6th St
Paducah, KY 42002
(270) 443-7060
DATE
5/10/2021
DEVICE DEVICE LOCATION DEVICE
ADDRESS
OR
ZONE
P A
SS
FA
IL
Se ns iti vi ty
NOTES:
FA MECHANIC ROOM p
KF MECHANIC ROOM p
BPS INSIDE IN ELECT ROOM p
BPS INSIDE IN ELECT ROOM p
VP MECHANIC ROOM p
SD ROOM 135 1D58 p 2.51 Range is 1.5 to 3.70
SD ROOM 135 1D59 P 2.28
PS ROOM 135 1M15 P
MS-SPK-S ROOM 135 P
SPK OUTSIDE ROOM 135 P
SD STORAGE ROOM 135B 1D60 P 2.96
SD HALL BY STORAGE 138 1D63 P 2.30
SPK HALL BY STORAGE 138 P
SD IN STORAGE 138 1D54 P 2.32
SD RESTROOM 134 BY RM 135 1D62 P 2.51
SD HALL NEAR EXIT BY 135 1D57 P 2.73
MS-SPK-S HALL NEAR EXIT BY 135 P
PS HALL EXIT BY 135 1M14 P
SPK OUTSIDE HALL EXIT BY 135 P
SD ROOM 136 1D55 P 2.76
SD ROOM 136 1D56 P 2.51
PS ROOM 136 1M13 P
MS-SPK-S ROOM 136 P
SPK OUTSIDE ROOM 136 P
SD STORAGE ROOM 136B 1D52 P 2.54
SD HALL BY ROOM 132 1D66 P 2.66
MS-SPK-S HALL BY ROOM 132 P
SD ROOM 132 1D65 P 2.63
SD ROOM 132 1D64 P 3.08
PS ROOM 132 1M16 P
FA = FIRE ALARM - KF = KINGFISHER - BPS = BOOSTER POWER SUPPLY - VP=VOICE/MASS PANEL - AN=ANNUNCIATOR/MASS CONSOLE - PS=MANUAL PULL - SD=SMOKE DETECTOR - DD=DUCT DETECTOR - HD = HEAT DETECTOR - MM=MONITOR MODULE - CR=CONTROL RELAY - CM=CONTROL MODULE - HS = HORN/STROBE - S=STROBE ONLY - MS=MASS STROBE - SPK=SPEAKER - DH=DOOR HOLDER
BUILDING NUMBERINSPECTION TEAM
KS, AS, RR 7404
FIRE ALARM
DEVICE REPORT
BUILDING 7404-5YR-5-10-2021 PAGE 3 OF 9
Suite #4 Louisville, KY 40299
(502) 614-8646
Premier Fire & Security Inc.
1251 N 6th St
Paducah, KY 42002
(270) 443-7060
DATE
5/10/2021
DEVICE DEVICE LOCATION DEVICE
ADDRESS
OR
ZONE
P A
SS
FA
IL
Se ns iti vi ty
NOTES:
FA = FIRE ALARM - KF = KINGFISHER - BPS = BOOSTER POWER SUPPLY - VP=VOICE/MASS PANEL - AN=ANNUNCIATOR/MASS CONSOLE - PS=MANUAL PULL - SD=SMOKE DETECTOR - DD=DUCT DETECTOR - HD = HEAT DETECTOR - MM=MONITOR MODULE - CR=CONTROL RELAY - CM=CONTROL MODULE - HS = HORN/STROBE - S=STROBE ONLY - MS=MASS STROBE - SPK=SPEAKER - DH=DOOR HOLDER
BUILDING NUMBERINSPECTION TEAM
KS, AS, RR 7404
FIRE ALARM
DEVICE REPORT
MS-SPK-S ROOM 132 P
SPK OUTSIDE ROOM 132 P
SD STORAGE RMM 132B 1D61 P 2.53
SD ROOM 139 1D50 P 2.69
SD ROOM 139 1D51 P 2.68
PS ROOM 139 1M12 P
MS-SPK-S ROOM 139 P
SPK OUTSIDE ROOM 139 P
SD STORAGE RMM 139B 1D53 P 2.68
PS Room 121 1M20 P
MS-SPK-S Room 121 P
SD Room 121 1D80 P 2.36 SD Storage Room 121B 1D78 P 2.48
PS HALL BY ROOM 121 1M21 P
MS-SPK-S HALL BY ROOM 121 P
SPK OUTSIDE EXIT BY ROOM 121 P
SD RESTROOM BY ROOM 121 1D77 P 2.25
MS-SPK-S RESTROOM BY ROOM 121 P
SD HALL NEAR ROOM 121 1D81 P 2.50
SD ROOM 124 1D76 P 2.56
MS-SPK-S ROOM 124 P
SD STORAGE ROOM 124B 1D79 P 2.13
PS ROOM 124 1M19 P
SPK OUTSIDE ROOM 124 P
SD ROOM 125 1D75 P 2.54
MS-SPK-S ROOM 125 P
SD STORAGE ROOM 125B 1D73 P 2.39
PS ROOM 125 1M18 P
SD HALL BY ROOM 125 1D86 P 2.41
SD ROOM 120 1D82 P 2.48
BUILDING 7404-5YR-5-10-2021 PAGE 4 OF 9
Suite #4 Louisville, KY 40299
(502) 614-8646
Premier Fire & Security Inc.
1251 N 6th St
Paducah, KY 42002
(270) 443-7060
DATE
5/10/2021
DEVICE DEVICE LOCATION DEVICE
ADDRESS
OR
ZONE
P A
SS
FA
IL
Se ns iti vi ty
NOTES:
FA = FIRE ALARM - KF = KINGFISHER - BPS = BOOSTER POWER SUPPLY - VP=VOICE/MASS PANEL - AN=ANNUNCIATOR/MASS CONSOLE - PS=MANUAL PULL - SD=SMOKE DETECTOR - DD=DUCT DETECTOR - HD = HEAT DETECTOR - MM=MONITOR MODULE - CR=CONTROL RELAY - CM=CONTROL MODULE - HS = HORN/STROBE - S=STROBE ONLY - MS=MASS STROBE - SPK=SPEAKER - DH=DOOR HOLDER
BUILDING NUMBERINSPECTION TEAM
KS, AS, RR 7404
FIRE ALARM
DEVICE REPORT
MS-SPK-S ROOM 120 P
SD STORAGE ROOM 120B 1D84 P 2.49
PS ROOM 120 1M22 P
SPK OUTSIDE ROOM 120 P
SD ROOM 117 1D85 P 2.51
MS-SPK-S ROOM 117 P
SD STORAGE ROOM 117 1D83 P 2.62
PS ROOM 117 1M23 P
SPK HALL BY ROOM 117 P
SD IN RESTROOM 127 BY 125 1D74 P 2.65
MS-SPK-S IN RESTROOM 127 BY 125 P
SD ROOM 116 1D87 P 2.11
MS-SPK-S ROOM 116 P
SD STORAGE ROOM 116B 1D90 P 2.25
PS ROOM 116 1M24 P
SPK OUTSIDE ROOM 116 P
SD HALL BY ROOM 127 1D91 P 2.30
SD ROOM 128 1D71 P 2.43
MS-SPK-S ROOM 128 P
SD STORAGE ROOM 128B 1D72 P 2.52
PS ROOM 128 1M17 P
SPK OUTSIDE ROOM 128 P
MS-SPK-S HALL BY ELECT EOOM 153 P
SD IN ELECT ROOM 153 1D68 P 2.47
SD stroller 130 1D67 P 2.13
SD HALL BY TRAINING ROOM 131 1D92 P 2.25
MS-SPK-S IN TRAINING ROOM 131 P
SD IN TRAINING ROOM 131 1D69 P 2.25
SD STORAGE ROOM 131B 1D70 P 2.30
SD ROOM 113 1D89 P 2.80
BUILDING 7404-5YR-5-10-2021 PAGE 5 OF 9
Suite #4 Louisville, KY 40299
(502) 614-8646
Premier Fire & Security Inc.
1251 N 6th St
Paducah, KY 42002
(270) 443-7060
DATE
5/10/2021
DEVICE DEVICE LOCATION DEVICE
ADDRESS
OR
ZONE
P A
SS
FA
IL
Se ns iti vi ty
NOTES:
FA = FIRE ALARM - KF = KINGFISHER - BPS = BOOSTER POWER SUPPLY - VP=VOICE/MASS PANEL - AN=ANNUNCIATOR/MASS CONSOLE - PS=MANUAL PULL - SD=SMOKE DETECTOR - DD=DUCT DETECTOR - HD = HEAT DETECTOR - MM=MONITOR MODULE - CR=CONTROL RELAY - CM=CONTROL MODULE - HS = HORN/STROBE - S=STROBE ONLY - MS=MASS STROBE - SPK=SPEAKER - DH=DOOR HOLDER
BUILDING NUMBERINSPECTION TEAM
KS, AS, RR 7404
FIRE ALARM
DEVICE REPORT
MS-SPK-S ROOM 113 P
SD STORAGE ROOM 113 1D88 P 2.70
PS IN ROOM 113 1M25 P
PS MAIN ENTRANCE 101 1M P
SPK OUTSIDE MAIN ENTRANCE P
MS-SPK-S MAIN LOBBY P
SD MAIN LOBBY WAITING ROOM 102 1D94 P 2.59
SD WAITING ROOM MENS ROOM 1D95 P 3.02
MS-SPK-S WAITING ROOM MENS ROOM P
SD WAITING ROOM WOMENS ROOM 1D96 P 3.00
MS-SPK-S WAITING ROOM WOMENS ROOM P
SD ENTRANCE 1D110 P 2.45
SD MAIN LOBBY 1D93 P 2.68
MS-SPK-S MAIN LOBBY P
SD MAIN LOBBY STORAGE 108 1D100 P 2.28
SD MAIN LOBBY RESTROOM 109 1D101 P 2.64
MS-SPK-S MAIN LOBBY RESTROOM 109 P
AN MAIN LOBBY REAR OPEN OFFICE P
AN MAIN LOBBY REAR OPEN OFFICE P
SD OPEN OFFICE 107 1D99 P 2.76
MS-SPK-S OPEN OFFICE 107 P
SD ASST DIR OFFICE 105 1D97 P 2.90
SPK ASST DIR OFFICE 105 P
SD DIR OFFICE 106 1D98 P 2.83
SPK DIR OFFICE 106 P
COMM ROOM 141 1D48 NO ACCESS TO SMOKE
MS-SPK-S COMM ROOM 141 P
MS-SPK-S STAFF LOUNGE 140 P
SD STAFF LOUNGE 140 1D49 P 2.35
MS-SPK-S HALL BY STAFF LOUNGE 140 P
BUILDING 7404-5YR-5-10-2021 PAGE 6 OF 9
Suite #4 Louisville, KY 40299
(502) 614-8646
Premier Fire & Security Inc.
1251 N 6th St
Paducah, KY 42002
(270) 443-7060
DATE
5/10/2021
DEVICE DEVICE LOCATION DEVICE
ADDRESS
OR
ZONE
P A
SS
FA
IL
Se ns iti vi ty
NOTES:
FA = FIRE ALARM - KF = KINGFISHER - BPS = BOOSTER POWER SUPPLY - VP=VOICE/MASS PANEL - AN=ANNUNCIATOR/MASS CONSOLE - PS=MANUAL PULL - SD=SMOKE DETECTOR - DD=DUCT DETECTOR - HD = HEAT DETECTOR - MM=MONITOR MODULE - CR=CONTROL RELAY - CM=CONTROL MODULE - HS = HORN/STROBE - S=STROBE ONLY - MS=MASS STROBE - SPK=SPEAKER - DH=DOOR HOLDER
BUILDING NUMBERINSPECTION TEAM
KS, AS, RR 7404
FIRE ALARM
DEVICE REPORT
SD IN CENTERAL STORAGE 142 1D47 P 2.65
SD HALL BY ROOM 143 1D46 P 2.56
SD IN ROOM 143 1D45 P 2.63
SD IN ROOM 143 1D44 P 2.34
MS-SPK-S IN ROOM 143 P
PS IN ROOM 143 1M11 P
SPK OUTSIDE ROOM 143 P
SD STORAGE ROOM 143B 1D42 P 2.64
MS-SPK-S KITCHEN 152 P
MS-SPK-S KITCHEN 152 P
HD KITCHEN 152 1D102 P
PS KITCHEN 152 1M28 P
SD KITCHEN STORAGE 152A 1D106 P 2.55
MM KITCHEN HOOD 1M27 P
SD HALL BY ROOM 146 1D103 P 2.60
SPK HALL BY ROOM 146 P
SD IN ROOM 146 1D40 P 2.61
SD IN ROOM 146 1D39 P 2.67
MS-SPK-S IN ROOM 146 P
PS IN ROOM 146 1M10 P
SD STORAGE ROOM 146B 1D43 P 2.73
MM FOR PIV IN ROOM 146 1M9 P
SD IN REST ROOM 145 BY 146 1D41 P 2.78
MS-SPK-S IN REST ROOM 145 BY 146 P
SD LAUNDRY ROOM 150 1D104 P 2.55
MS-SPK-S LAUNDRY ROOM 150 P
SD VIDEO ROOM 149 1D105 P 2.70
MS-SPK-S VIDEO ROOM 149 P
SD HALL BY ROOM 147 1D34 P 2.75
SD IN ROOM 147 1D35 P 2.86
BUILDING 7404-5YR-5-10-2021 PAGE 7 OF 9
Suite #4 Louisville, KY 40299
(502) 614-8646
Premier Fire & Security Inc.
1251 N 6th St
Paducah, KY 42002
(270) 443-7060
DATE
5/10/2021
DEVICE DEVICE LOCATION DEVICE
ADDRESS
OR
ZONE
P A
SS
FA
IL
Se ns iti vi ty
NOTES:
FA = FIRE ALARM - KF = KINGFISHER - BPS = BOOSTER POWER SUPPLY - VP=VOICE/MASS PANEL - AN=ANNUNCIATOR/MASS CONSOLE - PS=MANUAL PULL - SD=SMOKE DETECTOR - DD=DUCT DETECTOR - HD = HEAT DETECTOR - MM=MONITOR MODULE - CR=CONTROL RELAY - CM=CONTROL MODULE - HS = HORN/STROBE - S=STROBE ONLY - MS=MASS STROBE - SPK=SPEAKER - DH=DOOR HOLDER
BUILDING NUMBERINSPECTION TEAM
KS, AS, RR 7404
FIRE ALARM
DEVICE REPORT
SD IN ROOM 147 1D36 P 2.55
MS-SPK-S IN ROOM 147 P
SD IN RESTROOM IN 147 1D37 P 2.51
MS-SPK-S IN RESTROOM IN 147 P
SD STORAGE ROOM 147B 1D38 P 2.49
PS IN ROOM 147 1M8 P
SPK OUTSIDE ROOM 147 P
TS PN PIV 1M9 P
MS-SPK-S HALL BY RM 147 P
PS EXIT BY 147 1M7 P
SPK OUTSIDE BY 147 P
SPK OUTSIDE BY MECH ROOM P
TS SPRINKLER RISER 1M4 P
TS SPRINKLER RISER 1M5 P
WF SPRINKLER RISER 1M6 P
PS MECH ROOM 1M3 P
SD MECH ROOM 1D31 P 2.25
MS-SPK-S MECH ROOM P
DD MECH ROOM 1D32 P 2.97
CR AHU SHUTDOWN 1M107 P
DD MECH ROOM 1D33 P 2.64
SD ELECT ROOM 1D30 P 2.25
MS-SPK-S ELECT ROOM P
SPK OUTSIDE ELECT ROOM P
WA P
WPSR P
FDC P
INSPTEST P
PIV P
BUILDING 7404-5YR-5-10-2021 PAGE 8 OF 9
Sprinkler System Inspection
X
Yes No N/A Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A Yes No N/A
Air:Pilot:Pilot:
60 Static:System:
Air:
ANNUAL -
INSPECTION TYPE
5. Dry Pipe and Pre-action 5 Year
6. Pre-action Bi-Annual
SYSTEM TYPE
OTHER -
PRE-ACTION -
DRY PIPE -
WET PIPE -
McAuliffe WAY Fort Campbell KY 42223
5 YEAR -
2 YEAR -7404
Hydrostatic or Previous Gauge Readings
Is there a Backflow Device at the riser?
Current Gauge Readings Street: 50
Internally inspected, cleaned and free from damage?
Is air compressor in service and in
Residule:
Static:
OTHER -
Residule: 45 System: 60
Anti-freeze loops have correct solution mixture.
Does low air supply works properly?
Premier Fire & Security Inc.
1251 N 6th St
Paducah, KY 42002
(270) 443-7060
NCS
11501 Plantside Drive Suite #4 Louisville, KY 40299
(502) 614-8646
SPECIAL CONSIDERATIONS - List any unique functions to be aware of prior to testing
Are fire department caps in good condition?
Alarm test in proper position.
Does water flow devices work properly?
Is fire department connection accessible?
3. 2 Year and 5 Year Inspections:
and filled with the correct sprinkler heads?
Is sprinkler head cabinet mounted close to the riser
Are all control valves and trim in good condition?
5. Dry Pipe Bi-Annual
Trip valve, drain and clean internally Does quick opening devices work properly?
All low points drained?
All low points drained?
Are OS&Y stems lubricated?
All strainers cleaned and in proper condition.Operated valve to verify proper function?
Verified water travels through inspectors test.
Street: 50
INSPECTION DATES:
5/10/2021
Adequate heating, and on if necessary.
KS, AS, RR
INSPECTION TEAM:
Is hydrolic nameplace present and visible?
Are control valves supervised, lock or Tamper?
VALVE LOCATION
POC CONTACT INFO
BUILDING POC NAME
VALVE SIZE AND TYPE
NOTES, FAILURES AND SYSTEM DEVIATIONS FROM CONTRACT STANDARDS
Does low air supply works properly?
1.All Inspections:
BUILDING NUMBER
Verify water supply "conduct main drain test"
Gauges appear to be in working order ?
2.Annual, 2 Year and 5 Year Inspections:
ROOM 152 WALK IN HAS 2 DRY PENDENT HEADS OVER 10 YEARS OLD THAT NEED REPLACED.
ROOM 152 HAS 2 155DG CHROME PENDENT TYCO QUICK RESPONSE HEADS THAT ARE CORRODED.
MAKE
Is air pressure on the system satisfactory?
satisfactory operating condition?
Did system trip by device to verify operation?
Does quick opening devices work properly?
Did system trip by manual actuator?
MODEL NUMBER
MECH ROOM 4" CHECK 717RVICTAULIC
4. Wet Systems 5 Year Wet:
Is System in operation?
BUILDING 7404-5YR-5-10-2021 PAGE 9 OF 9
| 7402 As-Builts |
| CDC_Final_As_Builts_F-001 |
| CDC_Final_As_Builts_F-101 |
| CDC_Final_As_Builts_F-102 |
| CDC_Final_As_Builts_F-601 |
| 7402_5YR_05-06-21 |
| 7404 As-Builts |
| CDC_MD01-F-001 |
| References |
| Top, .. |
| .. |
| .. |
| .. |
| ARC_HQF-HF-001--.dgn, Default |
| .. |
| General |
| HNC_AnsiD-EngSht.dgn |
| CDC_MD01-F-101 |
| References |
| scrFP, .. |
| .. |
| Extractions |
| Architectural |
| CDC_MD01-EX_A-FP.dgn |
| CDC_MD01-FA-101 |
| References |
| scrFP, .. |
| .. |
| Extractions |
| Architectural |
| CDC_MD01-EX_A-FP.dgn |
| SCRROOM ID, .. |
| .. |
| Extractions |
| Architectural |
| CDC_MD01-EX_A-ROOM NAMES2.dgn |
| .. |
| General |
| CDC_MD01-G-KEY PLAN.dgn |
| HNC_AnsiD-EngSht.dgn |
| CDC_MD01-FP-101 |
| CDC_MD01-FP-101 |
7404_5YR_05-10-21
File details come from the government source that posted it. Updated .