Att 004 - Fire Alarm Reference Materials - Bldgs 7402 _7404.pdf

PDF 5 MB Posted

Attached to
Fire Alarm Replacement Federal contract opportunity
Solicitation number
W9124823Q0011
Issued by
Department of the Army Materiel Command Mission and Installation Contracting Command

About this file

This document provides as-built drawings and inspection reports for fire alarm systems at two child development centers on Fort Campbell, Kentucky. The drawings and reports are for buildings 7402 and 7404 and include floor plans, riser diagrams, and device locations. Inspections found issues such as outdated smoke detectors, corroded sprinkler heads, and batteries failing power tests. The Kingfisher mass notification panel at building 7402 had troubles that were not being monitored. Building 7404 inspections noted dry pendent sprinkler heads over ten years old in need of replacement. The related federal contract opportunity is a solicitation from the Department of the Army Materiel Command Mission and Installation Contracting Command for fire alarm replacement services at an unspecified location. No further details are provided on the opportunity.

View the file

Other files for this federal contract opportunity

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

B R

O W

N

IN

G

C A

M P

B E

L L

N O

N E

File Name:

Sheet Number:

A B C D E F G H

* * * S U P P O R T V A L U E E N G I N E E R I N G - I T P A Y S * * *

A B C D E F G H of Engineers

US Army Corps

* * * S A F E T Y P A Y S * * *

C O

L E

M A

N C

R A

G E

R

W

D Y

D

C Y

P N

F Y

F T

C A

M P

B E

L L

K E

N T

U C

K Y

110Sheet of

M

A R

F001

L E

G E

N D

N O

T

IF

IC

A T

IO

N

P

O T

E C

T

IO

N /M

A S

F

IR

E

A p p r

D a t e

D e s c r ip t io n

R e v is io n s

S y m b o l

D r a w in g c o d e c a le

D a t e

P r o je t n g in e e r

A r c h it e c

D a t e

C h e c k e d b y

D r a w n b y

D e s ig n d b y

C

Y

C O

O K

O

U G

L A

L

M O

N

T

D

A R

C H

IT

E C

G

IN

E E c o n s e n t o f

H r b e r t

In t e r n a t io n a l.

r e p r o d u c e d p h y s ic a ll y o r d ig it a ll w it h o u t t h e e x p r e s s r it t h e s c u m e n m y n o t o p r ie t a r y a n f id e n t ia l:

h o o l

A g e -1

M e d iu m

C h il d D e v e lo p m e n t

C e n te

-B

U

IL

T

VS

P

MIC

FAA

FACP

EVAC

TAMPER DETECTOR

POST INDICATOR VALVE

MASS NOTIFICATION PANEL

FIRE ALARM SPRINKLER BELL

FLOW DETECTOR/SWITCH

FIRE ALARM CONTROL PANEL

SMOKE DETECTOR BASIC

MANUAL STATION-PULL STATION

REM. MIC FOR MASS NOTIFICATION SYSTEM

FIRE ALARM REMOTE ANNUNCIATOR PANEL

MASS NOTIFICATION AND FIRE ALARM STROBES, MOUNTED SIDE BY SIDE

SPEAKER/HORN (ELECTRIC HORN)

SMOKE DETECTOR FOR DUCT

FIRE PROTECTION/MASS NOTIFICATION LEGEND

KITCHEN

TEACHING/DEMO

KITCHEN

STAFF LOUNGE

109A

STORAGE

109B

STAFF TOILET/FIRST AID

COMM

VESTIBULE

ATRIUM 2

ATRIUM 1

GATHERING AREA

HC TOILET

STAFF/PUBLIC/

TRAINING ROOM

CORRIDOR 1

STORAGE

SECURE

COMPUTER LAB

HOMEWORK CENTER

ACTIVITY ROOM 1

GIRLS

BOYS

FRONT DESK

ELEC 2

VESTIBULE

SCALE: 1/8" = 1’-0"

0 16’4’ 8’

JANITOR

C A

M P

B E

L L

B R

O W

N

IN

G

’0

File Name:

Sheet Number:

A B C D E F G H

* * * S U P P O R T V A L U E E N G I N E E R I N G - I T P A Y S * * *

A B C D E F G H of Engineers

US Army Corps

* * * S A F E T Y P A Y S * * *

C O

L E

M A

N C

R A

G E

R

W

D Y

D

C Y

P N

F Y

F T

C A

M P

B E

L L

K E

N T

U C

K Y

110Sheet of

M

A R

FAA

P

P

P

PPP

P

P

VS

V S

V S

V S

V S

V S

V S

V S

VS

V S

VS

VS

VS

V S

VS

VS

VS

VS

VS

V S

VS

V S

V

M

IC

VS

MC

PART "B"

PART "A"

KEY PLAN

F101

P L

A N P

A R

T A

N O

T

IF

IC

A T

IO

N F

L O

O T

E C

T

IO

N /M

A p r

D a t e

D e s c r ip t io n

R e v is io n s

S y m b o l

D r a w in g c o d a le

D a t e

P r o je g in e e r

A r c h it e c t e

C h e c k e d b y

D r a w n b y

D e s ig n

C O

O

U G

L A

M O

N

D

A R

C H

IT

E C

G

IN

E E c o n s e n t r b e r t

In t e r n a t io n a l.

r e p r o d u c e d p h y s ic a ll y o r d ig it a h o u t t h e e x p r e s s it t e c u m e n y n o t o p r ie t a r y a n f id e n t h o o l

A g e -1

M e d iu m

C h il d D e v e lo p m e n t

C e n

-B

U

IL

T

FAA

P

P

P

PPP

P

P

VS

V S

V S

V S

V S

V S

V S

V S

VS

V S

VS

VS

VS

V S

VS

VS

VS

VS

VS

V S

VS

V S

IC

MATCHLINE

MATCHLINE MATCHLINE

MATCHLINE

MC

EF-3

60 60 60

WF

NORTH

SCALE: 1/8"=1’-0"F101

COOLER

WALK-IN

BOYS

GIRLS

ACTIVITY ROOM

PERFORMING ARTS

OFFICE

DIRECTOR’S

F101

FIRE PROTECTION/MASS NOTIFICATION FLOOR PLAN - PART A

STORAGE

DRY FOOD

ELECTRICAL

LAUNDRY

MULTI-PURPOSE

MECHANICAL

MAIN ATRIUM

STORAGE

JANITOR

CORRIDOR

STORAGE AND ISSUE

FEMALE

MALE

VESTIBULE

MONITOR

VIDEO

SCALE: 1/8" = 1’-0"

0 16’4’ 8’

B R

O W

N

IN

G

C A

M P

B E

L L

’0

File Name:

Sheet Number:

A B C D E F G H

* * * S U P P O R T V A L U E E N G I N E E R I N G - I T P A Y S * * *

A B C D E F G H of Engineers

US Army Corps

* * * S A F E T Y P A Y S * * *

C O

L E

M A

N C

R A

G E

R

W

D Y

D

C Y

P N

F Y

F T

C A

M P

B E

L L

K E

N T

U C

K Y

110Sheet of

M

A R

P

FACP

P

P

P

P

P

P

P

P

P

P

P

VS

V S

VS

VS

VS

VS VS

VS

V S

VS

VS

VS

V S

EVAC

PART "B"

PART "A"

KEY PLAN

F102

STORAGE

MULTI-PURPOSE

GIRLS

BOYS

ACTIVITY ROOM

PERFORMING ARTS

ACTIVITY ROOM

ARTS & SCIENCE

COMM

P L

A N P

A R

T B

N O

T

IF

IC

A T

IO

N F

L O

O T

E C

T

IO

N /M

A p r

D a t e

D e s c r ip t io n

R e v is io n s

S y m b o l

D r a w in g c o d a le

D a t e

P r o je g in e e r

A r c h it e c t e

C h e c k e d b y

D r a w n b y

D e s ig n

C O

O

U G

L A

M O

N

D

A R

C H

IT

E C

G

IN

E E c o n s e n t r b e r t

In t e r n a t io n a l.

r e p r o d u c e d p h y s ic a ll y o r d ig it a h o u t t h e e x p r e s s it t e c u m e n y n o t o p r ie t a r y a n f id e n t h o o l

A g e -1

M e d iu m

C h il d D e v e lo p m e n t

C e n

-B

U

IL

T

P

FACP

P

P

P

P

P

P

P

P

P

P

P

VS

V S

VS

VS

VS

VS VS

VS

V S

VS

VS

VS

V S

EVAC

NOTE 1

NOTE 1

NOTE 1NOTE 1

NOTE 1

NOTE 1

MATCHLINE

MATCHLINE MATCHLINE

MATCHLINE

NOTE 2 NOTE 2

PROTECTIVE COVER.

2. INDICATED DEVICES PROVIDE WITH

PROVIDED WITH A WIRE GUARD.

1. INDICATED DEVICES TO BE

NOTES:

M C

AHU-1

M C

AHU-2

MC

RF-1

MC

RF-2

75 75

60 60

30 30

WF

W F

W F

WF

NORTH

SCALE: 1/8"=1’-0"F102F102

FIRE PROTECTION/MASS NOTIFICATION FLOOR PLAN - PART B

O W

N

IN

G

C A

M P

B E

L L

N O

N E

File Name:

Sheet Number:

A B C D E F G H

* * * S U P P O R T V A L U E E N G I N E E R I N G - I T P A Y S * * *

A B C D E F G H of Engineers

US Army Corps

* * * S A F E T Y P A Y S * * *

C O

L E

M A

N C

R A

G E

R

W

D Y

D

C Y

P N

F Y

F T

C A

M P

B E

L L

K E

N T

U C

K Y

110Sheet of

M

A R

1. VERIFY WITH CONTRACTING OFFICER LOCATION OF ANTENNA. PROVIDE LIGHTNING

PROTECTION FOR ANTENNA PER SPECIFICATIONS.

NOTES:

NOTE 2

2. FROM FIRE ALARM SYSTEM CONTROL PANEL FOR NOTIFICATION TO THE MASS

NOTIFICATION SYSTEM CONTROL PANEL THAT SYSTEM ACTIVATION IS ALLOWED.

FIRE ALARM SYSTEM WILL SILENCE ITSELF AND SYNCHRONIZE THE STROBES.

NOTE 3

AFTER THE MASS NOTIFICATION ANNOUNCEMENT IS COMPLETE, THE FIRE ALARM

AUDIBLE SIGNAL SHALL CONTINUE IF THE FIRE ALARM IS STILL IN ALARM.

3. MASS NOTIFICATION AND FIRE ALARM SYSTEMS CONTROL PANELS, ALTHOUGH

INSTALLED IN SEPARATE PANELS, WILL BE A COMBINATION SYSTEM. SYSTEMS WILL

BE NOTHAVE INTEGRATED FUNCTIONS AND WILL SHARE DEVICES. STROBES WILL

SHARED. THE SPEAKERS AND HORNS CONNECTED TO THE MASS NOTIFICATION

SYSTEM WILL ALSO BE USED BY THE FIRE ALARM SYSTEM.

FAA

F601

R

IS

E R

N O

T

IF

IC

A T

IO

O T

E C

T

IO

N /M

A

SCALE: NONEF601 F601

FIRE PROTECTION/MASS NOTIFICATION RISER

A p p r

D a t e

D e s c r ip t io n

R e v is io n s

S y m b o l

D r a w in g c o d a le

D a t e

P r o je g in e e r

A r c h it e c t e

C h e c k e d b y

D r a w n b y

D e s ig n

C O

O

U G

L A

M O

N

D

A R

C H

IT

E C

G

IN

E E c o n s e n t r b e r t

In t e r n a t io n a l.

r e p r o d u c e d p h y s ic a ll y o r d ig it a h o u t t h e e x p r e s s it t e c u m e n y n o t o p r ie t a r y a n f id e n t h o o l

A g e -1

M e d iu m

C h il d D e v e lo p m e n t

C e n

-B

U

IL

T

FINISHED FLOOR

FLOW BELL

WATER

SPRINKLER

BATTERY

CABINET

FACP

MM LVSS

ANTENNA

P

V

V

NOTE 1

C. CONNECT SPRINKLER WATER FLOW BELL PER MANUFACTURER’S REQUIREMENTS

A. KING FISHER RADIO TRANSMITTER IS GOVERNMENT FURNISHED, CONTRACTOR

INSTALLED. COAXIAL CABLE AND CONDUIT WILL BE PROVIDED AND INSTALLED

GENERAL NOTES:

BY CONTRACTOR. VERIFY LOCATION WITH CONTRACTING OFFICER AND FT.

CAMPBELL FIRE DEPARTMENT. VERIFY ZONES WITH FIRE DEPARTMENT.

D. SEE FLOOR PLANS FOR THE NUMBER AND LOCATION OF EQUIPMENT AND

DEVICES.

E. MINIMUM OF #12 AWG GROUNDS WILL BE USED.

CM

TO HVAC

SYSTEM

SHUTOFF

CM

BATTERY

CABINET

F. SEE SHEET E-001 FOR THE SYMBOL LEGEND IDENTIFYING THE MASS NOTIFICATION

SYSTEM DEVICES.

TAMPER

SWITCH

FLOW

SWITCH

TRANSMITTER

RADIO

KING

FISHER

MM MM

G. CIRCUIT BREAKERS FOR THE FACP AND FA RADIO SHALL BE RED AND SHALL BE

PROVIDED WITH A MECHANICAL LOCKING DEVICE. WRITE CIRCUIT NUMBER INSIDE

CONTROL PANEL.

V

MIC

VSVS

TAMPER

SWITCH

AT PIV

EVAC

ABBREVIATIONS:

CM CONTROL MODULE

MM MONITOR MODULE

LA-38

LA-42LA-40 B. NOT USED.

LVSS LOW VOLTAGE SURGE SUPPRESSION

LVSS

LVSS LVSS

X

BATTERY VOLTAGE TYPE:

VDC VDC AH 12

VDC VDC AH 12

VDC VDC AH 12

VDC VDC AH 12

ELEVATOR SYSTEM(S)

SHUNT

BATTERY VOLTAGE TYPE:

VDC VDC AH

VDC VDC AH

1 YEAR -

INSPECTION TYPE

BUILDING NUMBER 2 YEAR -

5 YEAR -

OTHER -

35.0 AMP

MODELRESPONSE TO ALARM MANUFACTURER

AMP

AMP

SWAPPED BATTERY CHARGING LOCATIONLED TESTTRANSMITTER RECEIVES ALARMS FROM FACP TRANSMITTER RECEIVES TROUBLES FROM FACP

NCS

11501 Plantside Drive Suite #4 Louisville, KY 40299

(502) 614-8646

Premier Fire & Security Inc.

1251 N 6th St

Paducah, KY 42002

(270) 443-7060

VDC

MONITORING AGENCY PERSONNEL NOTIFIED

MODEL

CENTERAL DISPATCH 270-798-1221

MONITORING AGENCY

McAuliffe WAY Fort Campbell KY 42223

FIRE ALARM CONTROL PANEL (FACP)

BUILDING POC NAME

PANEL MANUFACTURER

KS, BH, RR

INSPECTION DATES:

27.58

BATTERY CHARGING VOLTAGE

POC CONTACT INFO

NFS2-640

INSPECTION TEAM:

13.84

CIRCUIT BREAKER LOCATION

LOCATION

ELECT ROOM

AMP

FAIL @ 29%

FAIL @ 44%

VDC

15.3

TIME:

NOTIFIER

13.77

DIGITAL ALARM RADIO TRANSMITTER (DART)

VDC 35.0

LAMPS / LED TEST

LOCATION

SECONDARY RECALL RECALL

No Access to smoke in Comm Rm. 131

NOTES, FAILURES AND SYSTEM DEVIATIONS FROM CONTRACT STANDARDS

4 total 12V-35AMP Batteries in FACP/Mass failed the AMP test. Notified COR

FIRE ALARM

PANEL REPORT

VDC

BATTERY CHARGING VOLTAGE

PANEL MANUFACTURER

5/6/2021

RESPONSE TO TROUBLE

ANNUNCIATOR

SPECIAL CONSIDERATIONS - List any unique functions to be aware of before testing

KINGFISHER

MODEL TYPE LOCATION

TIME:

HVAC SHUTDOWN

ELEVATOR RESTART FROM FIRE SYSTEM RESET

KFRI COMBO

RESPONSE TO SUPERVISORY TIME:

PASS

DOOR HOLDERS

HVAC AUTO RESTART FROM FACP RESET

PRIMARY RECALL

IS SYSTEM CONNECTED TO MONITORING AGENCY

13.66 4.45 FAIL @ 13% VDC 35.0 AMP

13.56 5.14 FAIL @ 15% VDC 35.0 AMP

BUILDING 7402-5YR-5-6-2021-NC PAGE 1 OF 10

VDC VDC AH 12

VDC VDC AH 12

BATTERY VOLTAGE TYPE:

VDC VDC AH 12

VDC VDC AH 12

BATTERY VOLTAGE TYPE:

VDC VDC AH 12

VDC VDC AH 12

BATTERY VOLTAGE TYPE:

VDC VDC AH 12

VDC VDC AH 12

BATTERY VOLTAGE TYPE:

VDC VDC AH 12

VDC VDC AH 12

2 YEAR -

BUILDING POC NAME 5 YEAR -

POC CONTACT INFO OTHER -

BUILDING NUMBER 7402 McAuliffe WAY Fort Campbell KY 42223

INSPECTION DATES: INSPECTION TEAM: INSPECTION TYPE

5/6/2021 KS, BH, RR 1 YEAR -

NOTES, FAILURES AND SYSTEM DEVIATIONS FROM CONTRACT STANDARDS

8.3

NOTIFIER FCPS-2458 NAC POWER

BATTERY CHARGING VOLTAGE

27.6 13.62 13.59

9 PASS @ 129%

LOCATION

13.75 9.3

VDC 7.0 AMPPASS @ 133%

LOCATION

20.5

NAC POWER ELECT ROOM

PURPOSE

VDC 18.0 AMPPASS @ 114%

POWER EXPANDER/AUDIO-VISUAL PANEL

MODELPANEL MANUFACTURER PURPOSE

AMP-A2

12.52

PASS

BATTERY CHARGING VOLTAGE

26.25 12.48 24

NOTIFIER DAA-75-25 AMP-BACKUP ELECT ROOM

13.72

LOCATIONPURPOSE

NOTIFIER

PANEL MANUFACTURER MODEL

NOTIFIER FCPS-2458

BATTERY CHARGING VOLTAGE

27.6

POWER EXPANDER/AUDIO-VISUAL PANEL

DAA-75-25 AMP-A3 ELECT ROOM

VDC 18.0 AMP12.46 20.5

12.48

PASS @ 114%

PANEL MANUFACTURER

POWER EXPANDER/AUDIO-VISUAL PANEL

LOCATIONPURPOSEMODEL

AMP12.46 20.5

18.0

POWER EXPANDER/AUDIO-VISUAL PANEL

NOTIFIER

PANEL MANUFACTURER MODEL PURPOSE LOCATION

ELECT ROOM

AMP

AMP

VDC 7.0

VDC

12.49 8.3

8.65 PASS @ 124%

VDC 7.0

ELECT ROOM

VDC 7.0

POWER EXPANDER/AUDIO-VISUAL PANEL

PASS @ 129%

MODEL

BATTERY CHARGING VOLTAGE

26.5

VDC

PASS @ 119% AMP

AMP

VDC AMP7.0

AMP

VDC 18.0

NCS

11501 Plantside Drive Suite #4 Louisville, KY 40299

(502) 614-8646

DAA-75-25

BATTERY CHARGING VOLTAGE

26.25

PANEL MANUFACTURER

Premier Fire & Security Inc.

1251 N 6th St

Paducah, KY 42002

(270) 443-7060

AUXILIARY

PANEL REPORT

7.0

PASS @ 133%

PASS @ 114%

PASS

PASS

PASS

PASS

PASS @ 119%

BUILDING 7402-5YR-5-6-2021-NC PAGE 2 OF 10

VDC VDC AH 12

VDC VDC AH 12

BATTERY VOLTAGE TYPE:

VDC VDC AH

VDC VDC AH

BATTERY VOLTAGE TYPE:

VDC VDC AH

VDC VDC AH

BATTERY VOLTAGE TYPE:

VDC VDC AH

VDC VDC AH

BATTERY VOLTAGE TYPE:

VDC VDC AH

VDC VDC AH

NCS

11501 Plantside Drive Suite #4 Louisville, KY 40299

(502) 614-8646

AUXILIARY

PANEL REPORT

Premier Fire & Security Inc.

1251 N 6th St

Paducah, KY 42002

(270) 443-7060

INSPECTION DATES: INSPECTION TEAM: INSPECTION TYPE

5/6/2021 KS, BH, RR 1 YEAR -

BUILDING NUMBER 7402 McAuliffe WAY Fort Campbell KY 42223 2 YEAR -

NAC POWER ELECT ROOM

BUILDING POC NAME 5 YEAR -

POC CONTACT INFO OTHER -

VDC 7.0 AMP

POWER EXPANDER/AUDIO-VISUAL PANEL

PANEL MANUFACTURER MODEL PURPOSE LOCATION

NOTIFIER FCPS-2458

7.3 PASS @ 104% VDC

BATTERY CHARGING VOLTAGE

27.5 PASS 13.5 7.3 PASS @ 104%

7.0 AMP

POWER EXPANDER/AUDIO-VISUAL PANEL

PANEL MANUFACTURER MODEL PURPOSE LOCATION

13.47

BATTERY CHARGING VOLTAGE

VDC AMP

VDC AMP

POWER EXPANDER/AUDIO-VISUAL PANEL

PANEL MANUFACTURER MODEL PURPOSE LOCATION

BATTERY CHARGING VOLTAGE

VDC AMP

VDC AMP

POWER EXPANDER/AUDIO-VISUAL PANEL

PANEL MANUFACTURER MODEL PURPOSE LOCATION

BATTERY CHARGING VOLTAGE

VDC AMP

VDC AMP

POWER EXPANDER/AUDIO-VISUAL PANEL

PANEL MANUFACTURER MODEL PURPOSE LOCATION

BATTERY CHARGING VOLTAGE

VDC AMP

VDC AMP

NOTES, FAILURES AND SYSTEM DEVIATIONS FROM CONTRACT STANDARDS

BUILDING 7402-5YR-5-6-2021-NC PAGE 3 OF 10

NCS

11501 Plantside Drive Suite #4 Louisville, KY 40299

(502) 614-8646

Premier Fire & Security Inc.

1251 N 6th St

Paducah, KY 42002

(270) 443-7060

DATE

5/6/2021

DEVICE DEVICE LOCATION DEVICE

ADDRESS

OR

ZONE

P A

SS

FA

IL

Se ns iti vi ty

NOTES:

FA MECHANIC ROOM P

KF MECHANIC ROOM P

BPS MECHANIC ROOM P

BPS MECHANIC ROOM P

BPS MECHANIC ROOM P

BPS MECHANIC ROOM P

BPS MECHANIC ROOM P

VN MECHANIC ROOM WITH FACP P

HS MECHANIC ROOM WITH FACP P

VN MECHANIC ROOM WITH SPRINKLER P

VN MECHANIC ROOM WITH SPRINKLER P

HS MECHANIC ROOM WITH SPRINKLER P

HS MECHANIC ROOM WITH SPRINKLER P

VN OUTSIDE MECHANIC ROOM WITH

SPRINKLER

P

VN OUTSIDE MECHANIC ROOM WITH

SPRINKLER

P

HS OUTSIDE MECHANIC ROOM WITH

SPRINKLER

P

HS OUTSIDE MECHANIC ROOM WITH

SPRINKLER

P

AB OUTSIDE MECHANIC ROOM WITH

SPRINKLER

P

VN OUTSIDE LEFT OF ENTRANCE P

HS OUTSIDE LEFT OF ENTRANCE P

VN OUTSIDE BY MAIN DR P

HS OUTSIDE BY MAIN DR P

VN PLAYGROUND AREA OUTSIDE P

VN PLAYGROUND AREA OUTSIDE P

HS PLAYGROUND AREA OUTSIDE P

HS PLAYGROUND AREA OUTSIDE P

HS PLAYGROUND AREA OUTSIDE P

VN FRONT EXIT P

AN FRONT EXIT P

AN FRONT DESK AREA P

FA = FIRE ALARM - KF = KINGFISHER - BPS = BOOSTER POWER SUPPLY - VP=VOICE/MASS PANEL - AN=ANNUNCIATOR/MASS CONSOLE - PS=MANUAL PULL - SD=SMOKE DETECTOR - DD=DUCT DETECTOR - HD = HEAT DETECTOR - MM=MONITOR MODULE - CR=CONTROL RELAY - CM=CONTROL MODULE - HS = HORN/STROBE - S=STROBE ONLY - MS=MASS STROBE - SPK=SPEAKER - DH=DOOR HOLDER

BUILDING NUMBERINSPECTION TEAM

KS, BH, RR 7402

FIRE ALARM

DEVICE REPORT

BUILDING 7402-5YR-5-6-2021-NC PAGE 4 OF 10

Suite #4 Louisville, KY 40299

(502) 614-8646

Premier Fire & Security Inc.

1251 N 6th St

Paducah, KY 42002

(270) 443-7060

DATE

5/6/2021

DEVICE DEVICE LOCATION DEVICE

ADDRESS

OR

ZONE

P A

SS

FA

IL

Se ns iti vi ty

NOTES:

FA = FIRE ALARM - KF = KINGFISHER - BPS = BOOSTER POWER SUPPLY - VP=VOICE/MASS PANEL - AN=ANNUNCIATOR/MASS CONSOLE - PS=MANUAL PULL - SD=SMOKE DETECTOR - DD=DUCT DETECTOR - HD = HEAT DETECTOR - MM=MONITOR MODULE - CR=CONTROL RELAY - CM=CONTROL MODULE - HS = HORN/STROBE - S=STROBE ONLY - MS=MASS STROBE - SPK=SPEAKER - DH=DOOR HOLDER

BUILDING NUMBERINSPECTION TEAM

KS, BH, RR 7402

FIRE ALARM

DEVICE REPORT

AN FRONT DESK AREA P

VN FRONT DESK AREA P

HS FRONT DESK AREA P

VN CAFETERIA AREA P

HS CAFETERIA AREA P

VN KITCHEN P

HS KITCHEN P

HS CAFETERIA AREA P

VN CAFETERIA AREA P

HS BOYS ROOM P

VN BOYS ROOM P

HS GIRLS ROOM P

VN GIRLS ROOM P

HS STORAGE ROOM 117 P

VN STORAGE ROOM 117 P

VN COMMON AREA P

HS COMMON AREA P

VN COMMON AREA P

VN COMMON AREA P

VN COMMON AREA P

VN GYM P

VN GYM P

HS GYM P

HS GYM P

HS ROOM 120 P

VN ROOM 120 P

VN OUTSIDE BACK WALL P

VN OUTSIDE BACK WALL P

HS OUTSIDE BACK WALL P

HS OUTSIDE BACK WALL P

BUILDING 7402-5YR-5-6-2021-NC PAGE 5 OF 10

Suite #4 Louisville, KY 40299

(502) 614-8646

Premier Fire & Security Inc.

1251 N 6th St

Paducah, KY 42002

(270) 443-7060

DATE

5/6/2021

DEVICE DEVICE LOCATION DEVICE

ADDRESS

OR

ZONE

P A

SS

FA

IL

Se ns iti vi ty

NOTES:

FA = FIRE ALARM - KF = KINGFISHER - BPS = BOOSTER POWER SUPPLY - VP=VOICE/MASS PANEL - AN=ANNUNCIATOR/MASS CONSOLE - PS=MANUAL PULL - SD=SMOKE DETECTOR - DD=DUCT DETECTOR - HD = HEAT DETECTOR - MM=MONITOR MODULE - CR=CONTROL RELAY - CM=CONTROL MODULE - HS = HORN/STROBE - S=STROBE ONLY - MS=MASS STROBE - SPK=SPEAKER - DH=DOOR HOLDER

BUILDING NUMBERINSPECTION TEAM

KS, BH, RR 7402

FIRE ALARM

DEVICE REPORT

VN ROOM 125 P

HS ROOM 125 P

VN OUTSIDE GYM BATHROOM P

HS OUTSIDE GYM BATHROOM P

H BOYS ROOM P

VN BOYS ROOM P

H GIRLS ROOM P

VN GIRLS ROOM P

VN ROOM 129 P

HS ROOM 129 P

VN ROOM 130 P

HS ROOM 130 P

VN REC ROOM AREA P

VN REC ROOM AREA P

HS REC ROOM AREA P

HS REC ROOM AREA P

VN ROOM 131 P

HS ROOM 131 P

VN OUTSIDE FOYER P

VN BOYS ROOM REC. AREA P

HS BOYS ROOM REC. AREA P

VN GIRLS ROOM REC AREA P

HS GIRLS ROOM REC AREA P

VN ROOM 136 P

HS ROOM 136 P

VN ROOM 137 P

HS ROOM 137 P

VN ROOM 138 P

HS ROOM 138 P

VN ROOM 104 P

BUILDING 7402-5YR-5-6-2021-NC PAGE 6 OF 10

Suite #4 Louisville, KY 40299

(502) 614-8646

Premier Fire & Security Inc.

1251 N 6th St

Paducah, KY 42002

(270) 443-7060

DATE

5/6/2021

DEVICE DEVICE LOCATION DEVICE

ADDRESS

OR

ZONE

P A

SS

FA

IL

Se ns iti vi ty

NOTES:

FA = FIRE ALARM - KF = KINGFISHER - BPS = BOOSTER POWER SUPPLY - VP=VOICE/MASS PANEL - AN=ANNUNCIATOR/MASS CONSOLE - PS=MANUAL PULL - SD=SMOKE DETECTOR - DD=DUCT DETECTOR - HD = HEAT DETECTOR - MM=MONITOR MODULE - CR=CONTROL RELAY - CM=CONTROL MODULE - HS = HORN/STROBE - S=STROBE ONLY - MS=MASS STROBE - SPK=SPEAKER - DH=DOOR HOLDER

BUILDING NUMBERINSPECTION TEAM

KS, BH, RR 7402

FIRE ALARM

DEVICE REPORT

HS ROOM 104 P

VN ROOM 109A P

HS ROOM 109A P

VN RESTROOM NEAR FRONT DESK P

HS RESTROOM NEAR FRONT DESK P

VN ROOM 102 P

HS ROOM 102 P

SD Main Electrical Rm. 122 D-1 P 3.07 LEVELS ARE 0.5 TO 3.71 SD Multi-Purpose Stor. Rm. 120 D-2 P 2.27

DD AHU-2 Return D-3 P 2.4

DD AHU-1 Return D-4 P 2.54

HD Mechanical Rm. 119 D-5 P

HD Mechanical Rm. 119 D-6 P

SD Video Monitor Rm. 118 D-7 P 2.37

SD Storage Rm. 117 D-8 P 2.55

SD Girls Restroom Rm. 109 D-9 P 2.39

SD Boys Restroom Rm. 115 D-10 P 2.5

HD Kitchen Rm. 113 D-11 P

HD Kitchen Rm. 113 D-13 P

SD Dry Food Storage Rm. 112 D-14 P 2.84

SD Atrium-1 Rm. 114 D-15 P 2.5

SD Atrium-1 Rm. 114 D-16 P 2.52

SD Staff Lounge Rm. 109A D-17 P 2.44

SD Closet Rm. 105 D-18 P 2.24

SD Staff Toilet Rm. 107 D-19 P 2.56

SD Staff/Pòblic Toilet Rm. 108 D-20 P 2.34

SD Training Rm. 104 D-21 P 2.32

SD Front Desk Rm . 106 D-22 P 2.48

SD Director's Office Rm. 102 D-23 P 3.32

SD Corridor-1 Rm. 103 D-24 P 2.54

BUILDING 7402-5YR-5-6-2021-NC PAGE 7 OF 10

Suite #4 Louisville, KY 40299

(502) 614-8646

Premier Fire & Security Inc.

1251 N 6th St

Paducah, KY 42002

(270) 443-7060

DATE

5/6/2021

DEVICE DEVICE LOCATION DEVICE

ADDRESS

OR

ZONE

P A

SS

FA

IL

Se ns iti vi ty

NOTES:

FA = FIRE ALARM - KF = KINGFISHER - BPS = BOOSTER POWER SUPPLY - VP=VOICE/MASS PANEL - AN=ANNUNCIATOR/MASS CONSOLE - PS=MANUAL PULL - SD=SMOKE DETECTOR - DD=DUCT DETECTOR - HD = HEAT DETECTOR - MM=MONITOR MODULE - CR=CONTROL RELAY - CM=CONTROL MODULE - HS = HORN/STROBE - S=STROBE ONLY - MS=MASS STROBE - SPK=SPEAKER - DH=DOOR HOLDER

BUILDING NUMBERINSPECTION TEAM

KS, BH, RR 7402

FIRE ALARM

DEVICE REPORT

SD Vestibule Rm. 101 D-25 P 2.53

SD Computer Lab Rm. 136 D-26 P 2.58

SD Homework Rm. 137 D-27 P 2.58

SD Activity Rm. 136 D-28 P 3.1

SD Girls Restroom Rm. 134 D-29 P 3.07

SD Boys Restroom Rm. 133 D-30 P 3.1

SD Atrium-2 Rm. 135 D-31 P 2.7

SD Atrium-2 Rm. 135 D-32 P 2.73

SD Gathering Area Rm. 141 D-33 P 3.05

SD Main Atrium Rm. 140 D-34 P 2.47

SD Arts/Science/Activ. Rm. 129 D-35 P 2.5

SD Performing Arts Rm. 130 D-36 P 2.36

Comm. Room Rm. 131 D-37 NO ACCESS TO SMOKE SD Vestibule Rm. 132 D-38 P 2.88

SD Female Restroom Rm. 127 D-39 P 2.44

SD Male Restroom Rm. 128 D-40 P 2.05

SD Corridor 126 D-41 P 2.86

SD Storage/Issue Rm. 125 D-42 P 2.45

SD Multi-Purpose Rm. 124 D-44 P

SD Multi-Purpose # Rm. 124 D-45 P

SD Multi-Purpose Rm. 124 D-46 P

SD Multi-Purpose Rm. 124 D-47 P

DD AHU-1 Supply D-49 P 2.39

DD AHU-2 Supply D-50 P 2.51

SD Main Atrium Rm. 140 D-51 P 3.01

SD Storage Closet Rm. 136 D-52 P 2.44

SD Janitor Closet Rm. 121 D-53 P 2.9

SD Laundry Rm. 123 D-54 P 2.49

PS Main Electrical Rm. 122 M-1 P

PS Multi-Purpose Stor. Rm. 120 M-2 P

BUILDING 7402-5YR-5-6-2021-NC PAGE 8 OF 10

Suite #4 Louisville, KY 40299

(502) 614-8646

Premier Fire & Security Inc.

1251 N 6th St

Paducah, KY 42002

(270) 443-7060

DATE

5/6/2021

DEVICE DEVICE LOCATION DEVICE

ADDRESS

OR

ZONE

P A

SS

FA

IL

Se ns iti vi ty

NOTES:

FA = FIRE ALARM - KF = KINGFISHER - BPS = BOOSTER POWER SUPPLY - VP=VOICE/MASS PANEL - AN=ANNUNCIATOR/MASS CONSOLE - PS=MANUAL PULL - SD=SMOKE DETECTOR - DD=DUCT DETECTOR - HD = HEAT DETECTOR - MM=MONITOR MODULE - CR=CONTROL RELAY - CM=CONTROL MODULE - HS = HORN/STROBE - S=STROBE ONLY - MS=MASS STROBE - SPK=SPEAKER - DH=DOOR HOLDER

BUILDING NUMBERINSPECTION TEAM

KS, BH, RR 7402

FIRE ALARM

DEVICE REPORT

PS Mechanical Rm. 119 M-3 P

CR AHU-1 Shutdown M-4 P

PS Kitchen Rm. 113 M-6 P

MM Kitchen Hood ANSUL Rm. 113 M-7 P

PS Vestibule Rm. 101 M-10 P

PS Computer Lab Rm. 136 M-11 P

PS Homework Rm. 137 M-12 P

PS Activity-1 Rm. 136 M-13 P

PS Vestibule Rm. 132 M-14 P

PS Performing Arts Rm. 130 M-15 P

PS Arts/Science/Act. Rm. 129 M-16 P

PS Corridor 126 M-17 P

PS Storage/Issue RM. 125 M-18 P

PS Storage/Issue Rm. 125 M-19 P

PS Multi-Purpose Rm. 124 M-20 P

PS Multi-Purpose Rm. 124 M-21 P

WF Sprinkler Riser M-24 P

TS Sprinkler Riser M-25 P

TS PIV M-26 P

PS Atrium-1 Rm. 114 M-27 P

CR AHU-2 Shutdown M-28 P

MM Battery Charger M-30 P

PIV P

VP P

AN P

AN P

WA P

WPSR P

FDC P

INSPTEST P

BUILDING 7402-5YR-5-6-2021-NC PAGE 9 OF 10

Sprinkler System Inspection

X

Yes No N/A Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A Yes No N/A

MECH ROOM 4" CHECK 717RVICTAULIC

4. Wet Systems 5 Year Wet:

Is System in operation?

Dry Pendent head in cooler is past its 10 year date, needs replaced - Standard Response 155DG Janitor 121 - 1/2" - 155dg quick Response pendent head is painted.

MAKE

Is air pressure on the system satisfactory?

satisfactory operating condition?

Did system trip by device to verify operation?

Does quick opening devices work properly?

Did system trip by manual actuator?

MODEL NUMBER

BUILDING NUMBER

Verify water supply "conduct main drain test"

Gauges appear to be in working order ?

2.Annual, 2 Year and 5 Year Inspections:

Gauges are 2010 - past their certificaiton date 2 total

POC CONTACT INFO

BUILDING POC NAME

VALVE SIZE AND TYPE

NOTES, FAILURES AND SYSTEM DEVIATIONS FROM CONTRACT STANDARDS

Does low air supply works properly?

1.All Inspections:

INSPECTION DATES:

5/6/2021

Adequate heating, and on if necessary.

KS, BH, RR

INSPECTION TEAM:

Is hydrolic nameplace present and visible?

Are control valves supervised, lock or Tamper?

VALVE LOCATION

All low points drained?

All low points drained?

Are OS&Y stems lubricated?

All strainers cleaned and in proper condition.Operated valve to verify proper function?

Verified water travels through inspectors test.

Street:

and filled with the correct sprinkler heads?

Is sprinkler head cabinet mounted close to the riser

Are all control valves and trim in good condition?

5. Dry Pipe Bi-Annual

Trip valve, drain and clean internally Does quick opening devices work properly?

Anti-freeze loops have correct solution mixture.

Does low air supply works properly?

Premier Fire & Security Inc.

1251 N 6th St

Paducah, KY 42002

(270) 443-7060

NCS

11501 Plantside Drive Suite #4 Louisville, KY 40299

(502) 614-8646

SPECIAL CONSIDERATIONS - List any unique functions to be aware of prior to testing

Are fire department caps in good condition?

Alarm test in proper position.

Does water flow devices work properly?

Is fire department connection accessible?

3. 2 Year and 5 Year Inspections:

Internally inspected, cleaned and free from damage?

Is air compressor in service and in

Residule:

Static:

OTHER -

Residule: 55 System: 60

5 YEAR -

2 YEAR -7402

Hydrostatic or Previous Gauge Readings

Is there a Backflow Device at the riser?

Current Gauge Readings Street: 80

ANNUAL -

INSPECTION TYPE

5. Dry Pipe and Pre-action 5 Year

6. Pre-action Bi-Annual

SYSTEM TYPE

OTHER -

PRE-ACTION -

DRY PIPE -

WET PIPE -

McAuliffe WAY Fort Campbell KY 42223

80 Static:System:

Air: Air:Pilot:Pilot:

BUILDING 7402-5YR-5-6-2021-NC PAGE 10 OF 10

VDC VDC AH 12

VDC VDC AH 12

ELEVATOR SYSTEM(S)

SHUNT

BATTERY VOLTAGE TYPE:

VDC VDC AH

VDC VDC AH

PASS

DOOR HOLDERS

HVAC AUTO RESTART FROM FACP RESET PASS

PASS

PRIMARY RECALL

IS SYSTEM CONNECTED TO MONITORING AGENCY

RESPONSE TO SUPERVISORY TIME:

ELEVATOR RESTART FROM FIRE SYSTEM RESET

KFRI COMBO

PASS

ANNUNCIATOR

SPECIAL CONSIDERATIONS - List any unique functions to be aware of before testing

KINGFISHER

MODEL TYPE LOCATION

FAIL

TIME:

HVAC SHUTDOWN

FIRE ALARM

PANEL REPORT

VDC

BATTERY CHARGING VOLTAGE

PANEL MANUFACTURER

12:47pm

5/10/2021

RESPONSE TO TROUBLE

NO ACCESS TO SMOKE IN COMM ROOM 141

NOTES, FAILURES AND SYSTEM DEVIATIONS FROM CONTRACT STANDARDS

THE KINGFISHER.

2 TROUBLES ON PANEL UPON ARRIVAL, BOTH FOR MISSING LCD ANN CARDS. THE OCCUPANTS SAID DPW IS WORKING AND HAD TO ORDER PARTS. ALSO THE TROUBLES ARE NOT BEING MONITORED BY

27.5

TIME:

SIMPLEX

13.54

DIGITAL ALARM RADIO TRANSMITTER (DART)

VDC 35.0

LAMPS / LED TEST

LOCATION

SECONDARY RECALL RECALL

13.63

CIRCUIT BREAKER LOCATION

LOCATION

ELECT ROOM

AMP

PASS @ 72%

PASS @ 79%

VDC

INSPECTION DATES:

27.25

BATTERY CHARGING VOLTAGE

POC CONTACT INFO

25.25

4100UD

INSPECTION TEAM:

JOSH

MODEL

CENTERAL DISPATCH 270-798-1221

MONITORING AGENCY

McAuliffe WAY Fort Campbell KY 42223

FIRE ALARM CONTROL PANEL (FACP)

BUILDING POC NAME

PANEL MANUFACTURER

KS, AS, RR

NCS

11501 Plantside Drive Suite #4 Louisville, KY 40299

(502) 614-8646

Premier Fire & Security Inc.

1251 N 6th St

Paducah, KY 42002

(270) 443-7060

VDC

MONITORING AGENCY PERSONNEL NOTIFIED

SWAPPED BATTERY CHARGING LOCATIONLED TESTTRANSMITTER RECEIVES ALARMS FROM FACP TRANSMITTER RECEIVES TROUBLES FROM FACP

MODELRESPONSE TO ALARM MANUFACTURER

AMP

AMP

1 YEAR -

INSPECTION TYPE

PASS

BUILDING NUMBER 2 YEAR -

5 YEAR -

OTHER -

35.0 AMP

BUILDING 7404-5YR-5-10-2021 PAGE 1 OF 9

VDC VDC AH 12

VDC VDC AH 12

BATTERY VOLTAGE TYPE:

VDC VDC AH 12

VDC VDC AH 12

BATTERY VOLTAGE TYPE:

VDC VDC AH

VDC VDC AH

BATTERY VOLTAGE TYPE:

VDC VDC AH

VDC VDC AH

BATTERY VOLTAGE TYPE:

VDC VDC AH

VDC VDC AH

PASS

PASS @ 73%

NCS

11501 Plantside Drive Suite #4 Louisville, KY 40299

(502) 614-8646

BATTERY CHARGING VOLTAGE

27.6

PANEL MANUFACTURER

Premier Fire & Security Inc.

1251 N 6th St

Paducah, KY 42002

(270) 443-7060

AUXILIARY

PANEL REPORT

7.0

FAIL @ 5%

FAIL @ 0%

VDC

AMP

AMP

VDC AMP

AMP

VDC 7.0

VDC

VDC

POWER EXPANDER/AUDIO-VISUAL PANEL

MODEL

BATTERY CHARGING VOLTAGE

AMP

AMP

VDC 7.0

VDC

13.54 5.14

6.07 PASS @ 87%

13.59 0.00 7.0

POWER EXPANDER/AUDIO-VISUAL PANEL

SIMPLEX

PANEL MANUFACTURER MODEL PURPOSE LOCATION

ELECT ROOM

PANEL MANUFACTURER

POWER EXPANDER/AUDIO-VISUAL PANEL

LOCATIONPURPOSEMODEL

AMP

VDC AMP

PANEL MANUFACTURER MODEL

BATTERY CHARGING VOLTAGE

POWER EXPANDER/AUDIO-VISUAL PANEL

ELECT ROOM

2 total 12v-7amp batteries failed in booster panel inside building in elect room 153. notified COR

LOCATIONPURPOSE

BATTERY CHARGING VOLTAGE

27.5 13.65 0.33

SIMPLEX 4009 NAC POWER

MODELPANEL MANUFACTURER PURPOSE

NAC POWER

13.56

PASS

LOCATION

PURPOSE

VDC AMP

POWER EXPANDER/AUDIO-VISUAL PANEL

LOCATION

VDC AMP

NOTES, FAILURES AND SYSTEM DEVIATIONS FROM CONTRACT STANDARDS

BATTERY CHARGING VOLTAGE

INSPECTION DATES: INSPECTION TEAM: INSPECTION TYPE

5/10/2021 KS, AS, RR 1 YEAR -

2 YEAR -

BUILDING POC NAME 5 YEAR -

POC CONTACT INFO OTHER -

BUILDING NUMBER 7404 McAuliffe WAY Fort Campbell KY 42223

BUILDING 7404-5YR-5-10-2021 PAGE 2 OF 9

Suite #4 Louisville, KY 40299

(502) 614-8646

Premier Fire & Security Inc.

1251 N 6th St

Paducah, KY 42002

(270) 443-7060

DATE

5/10/2021

DEVICE DEVICE LOCATION DEVICE

ADDRESS

OR

ZONE

P A

SS

FA

IL

Se ns iti vi ty

NOTES:

FA MECHANIC ROOM p

KF MECHANIC ROOM p

BPS INSIDE IN ELECT ROOM p

BPS INSIDE IN ELECT ROOM p

VP MECHANIC ROOM p

SD ROOM 135 1D58 p 2.51 Range is 1.5 to 3.70

SD ROOM 135 1D59 P 2.28

PS ROOM 135 1M15 P

MS-SPK-S ROOM 135 P

SPK OUTSIDE ROOM 135 P

SD STORAGE ROOM 135B 1D60 P 2.96

SD HALL BY STORAGE 138 1D63 P 2.30

SPK HALL BY STORAGE 138 P

SD IN STORAGE 138 1D54 P 2.32

SD RESTROOM 134 BY RM 135 1D62 P 2.51

SD HALL NEAR EXIT BY 135 1D57 P 2.73

MS-SPK-S HALL NEAR EXIT BY 135 P

PS HALL EXIT BY 135 1M14 P

SPK OUTSIDE HALL EXIT BY 135 P

SD ROOM 136 1D55 P 2.76

SD ROOM 136 1D56 P 2.51

PS ROOM 136 1M13 P

MS-SPK-S ROOM 136 P

SPK OUTSIDE ROOM 136 P

SD STORAGE ROOM 136B 1D52 P 2.54

SD HALL BY ROOM 132 1D66 P 2.66

MS-SPK-S HALL BY ROOM 132 P

SD ROOM 132 1D65 P 2.63

SD ROOM 132 1D64 P 3.08

PS ROOM 132 1M16 P

FA = FIRE ALARM - KF = KINGFISHER - BPS = BOOSTER POWER SUPPLY - VP=VOICE/MASS PANEL - AN=ANNUNCIATOR/MASS CONSOLE - PS=MANUAL PULL - SD=SMOKE DETECTOR - DD=DUCT DETECTOR - HD = HEAT DETECTOR - MM=MONITOR MODULE - CR=CONTROL RELAY - CM=CONTROL MODULE - HS = HORN/STROBE - S=STROBE ONLY - MS=MASS STROBE - SPK=SPEAKER - DH=DOOR HOLDER

BUILDING NUMBERINSPECTION TEAM

KS, AS, RR 7404

FIRE ALARM

DEVICE REPORT

BUILDING 7404-5YR-5-10-2021 PAGE 3 OF 9

Suite #4 Louisville, KY 40299

(502) 614-8646

Premier Fire & Security Inc.

1251 N 6th St

Paducah, KY 42002

(270) 443-7060

DATE

5/10/2021

DEVICE DEVICE LOCATION DEVICE

ADDRESS

OR

ZONE

P A

SS

FA

IL

Se ns iti vi ty

NOTES:

FA = FIRE ALARM - KF = KINGFISHER - BPS = BOOSTER POWER SUPPLY - VP=VOICE/MASS PANEL - AN=ANNUNCIATOR/MASS CONSOLE - PS=MANUAL PULL - SD=SMOKE DETECTOR - DD=DUCT DETECTOR - HD = HEAT DETECTOR - MM=MONITOR MODULE - CR=CONTROL RELAY - CM=CONTROL MODULE - HS = HORN/STROBE - S=STROBE ONLY - MS=MASS STROBE - SPK=SPEAKER - DH=DOOR HOLDER

BUILDING NUMBERINSPECTION TEAM

KS, AS, RR 7404

FIRE ALARM

DEVICE REPORT

MS-SPK-S ROOM 132 P

SPK OUTSIDE ROOM 132 P

SD STORAGE RMM 132B 1D61 P 2.53

SD ROOM 139 1D50 P 2.69

SD ROOM 139 1D51 P 2.68

PS ROOM 139 1M12 P

MS-SPK-S ROOM 139 P

SPK OUTSIDE ROOM 139 P

SD STORAGE RMM 139B 1D53 P 2.68

PS Room 121 1M20 P

MS-SPK-S Room 121 P

SD Room 121 1D80 P 2.36 SD Storage Room 121B 1D78 P 2.48

PS HALL BY ROOM 121 1M21 P

MS-SPK-S HALL BY ROOM 121 P

SPK OUTSIDE EXIT BY ROOM 121 P

SD RESTROOM BY ROOM 121 1D77 P 2.25

MS-SPK-S RESTROOM BY ROOM 121 P

SD HALL NEAR ROOM 121 1D81 P 2.50

SD ROOM 124 1D76 P 2.56

MS-SPK-S ROOM 124 P

SD STORAGE ROOM 124B 1D79 P 2.13

PS ROOM 124 1M19 P

SPK OUTSIDE ROOM 124 P

SD ROOM 125 1D75 P 2.54

MS-SPK-S ROOM 125 P

SD STORAGE ROOM 125B 1D73 P 2.39

PS ROOM 125 1M18 P

SD HALL BY ROOM 125 1D86 P 2.41

SD ROOM 120 1D82 P 2.48

BUILDING 7404-5YR-5-10-2021 PAGE 4 OF 9

Suite #4 Louisville, KY 40299

(502) 614-8646

Premier Fire & Security Inc.

1251 N 6th St

Paducah, KY 42002

(270) 443-7060

DATE

5/10/2021

DEVICE DEVICE LOCATION DEVICE

ADDRESS

OR

ZONE

P A

SS

FA

IL

Se ns iti vi ty

NOTES:

FA = FIRE ALARM - KF = KINGFISHER - BPS = BOOSTER POWER SUPPLY - VP=VOICE/MASS PANEL - AN=ANNUNCIATOR/MASS CONSOLE - PS=MANUAL PULL - SD=SMOKE DETECTOR - DD=DUCT DETECTOR - HD = HEAT DETECTOR - MM=MONITOR MODULE - CR=CONTROL RELAY - CM=CONTROL MODULE - HS = HORN/STROBE - S=STROBE ONLY - MS=MASS STROBE - SPK=SPEAKER - DH=DOOR HOLDER

BUILDING NUMBERINSPECTION TEAM

KS, AS, RR 7404

FIRE ALARM

DEVICE REPORT

MS-SPK-S ROOM 120 P

SD STORAGE ROOM 120B 1D84 P 2.49

PS ROOM 120 1M22 P

SPK OUTSIDE ROOM 120 P

SD ROOM 117 1D85 P 2.51

MS-SPK-S ROOM 117 P

SD STORAGE ROOM 117 1D83 P 2.62

PS ROOM 117 1M23 P

SPK HALL BY ROOM 117 P

SD IN RESTROOM 127 BY 125 1D74 P 2.65

MS-SPK-S IN RESTROOM 127 BY 125 P

SD ROOM 116 1D87 P 2.11

MS-SPK-S ROOM 116 P

SD STORAGE ROOM 116B 1D90 P 2.25

PS ROOM 116 1M24 P

SPK OUTSIDE ROOM 116 P

SD HALL BY ROOM 127 1D91 P 2.30

SD ROOM 128 1D71 P 2.43

MS-SPK-S ROOM 128 P

SD STORAGE ROOM 128B 1D72 P 2.52

PS ROOM 128 1M17 P

SPK OUTSIDE ROOM 128 P

MS-SPK-S HALL BY ELECT EOOM 153 P

SD IN ELECT ROOM 153 1D68 P 2.47

SD stroller 130 1D67 P 2.13

SD HALL BY TRAINING ROOM 131 1D92 P 2.25

MS-SPK-S IN TRAINING ROOM 131 P

SD IN TRAINING ROOM 131 1D69 P 2.25

SD STORAGE ROOM 131B 1D70 P 2.30

SD ROOM 113 1D89 P 2.80

BUILDING 7404-5YR-5-10-2021 PAGE 5 OF 9

Suite #4 Louisville, KY 40299

(502) 614-8646

Premier Fire & Security Inc.

1251 N 6th St

Paducah, KY 42002

(270) 443-7060

DATE

5/10/2021

DEVICE DEVICE LOCATION DEVICE

ADDRESS

OR

ZONE

P A

SS

FA

IL

Se ns iti vi ty

NOTES:

FA = FIRE ALARM - KF = KINGFISHER - BPS = BOOSTER POWER SUPPLY - VP=VOICE/MASS PANEL - AN=ANNUNCIATOR/MASS CONSOLE - PS=MANUAL PULL - SD=SMOKE DETECTOR - DD=DUCT DETECTOR - HD = HEAT DETECTOR - MM=MONITOR MODULE - CR=CONTROL RELAY - CM=CONTROL MODULE - HS = HORN/STROBE - S=STROBE ONLY - MS=MASS STROBE - SPK=SPEAKER - DH=DOOR HOLDER

BUILDING NUMBERINSPECTION TEAM

KS, AS, RR 7404

FIRE ALARM

DEVICE REPORT

MS-SPK-S ROOM 113 P

SD STORAGE ROOM 113 1D88 P 2.70

PS IN ROOM 113 1M25 P

PS MAIN ENTRANCE 101 1M P

SPK OUTSIDE MAIN ENTRANCE P

MS-SPK-S MAIN LOBBY P

SD MAIN LOBBY WAITING ROOM 102 1D94 P 2.59

SD WAITING ROOM MENS ROOM 1D95 P 3.02

MS-SPK-S WAITING ROOM MENS ROOM P

SD WAITING ROOM WOMENS ROOM 1D96 P 3.00

MS-SPK-S WAITING ROOM WOMENS ROOM P

SD ENTRANCE 1D110 P 2.45

SD MAIN LOBBY 1D93 P 2.68

MS-SPK-S MAIN LOBBY P

SD MAIN LOBBY STORAGE 108 1D100 P 2.28

SD MAIN LOBBY RESTROOM 109 1D101 P 2.64

MS-SPK-S MAIN LOBBY RESTROOM 109 P

AN MAIN LOBBY REAR OPEN OFFICE P

AN MAIN LOBBY REAR OPEN OFFICE P

SD OPEN OFFICE 107 1D99 P 2.76

MS-SPK-S OPEN OFFICE 107 P

SD ASST DIR OFFICE 105 1D97 P 2.90

SPK ASST DIR OFFICE 105 P

SD DIR OFFICE 106 1D98 P 2.83

SPK DIR OFFICE 106 P

COMM ROOM 141 1D48 NO ACCESS TO SMOKE

MS-SPK-S COMM ROOM 141 P

MS-SPK-S STAFF LOUNGE 140 P

SD STAFF LOUNGE 140 1D49 P 2.35

MS-SPK-S HALL BY STAFF LOUNGE 140 P

BUILDING 7404-5YR-5-10-2021 PAGE 6 OF 9

Suite #4 Louisville, KY 40299

(502) 614-8646

Premier Fire & Security Inc.

1251 N 6th St

Paducah, KY 42002

(270) 443-7060

DATE

5/10/2021

DEVICE DEVICE LOCATION DEVICE

ADDRESS

OR

ZONE

P A

SS

FA

IL

Se ns iti vi ty

NOTES:

FA = FIRE ALARM - KF = KINGFISHER - BPS = BOOSTER POWER SUPPLY - VP=VOICE/MASS PANEL - AN=ANNUNCIATOR/MASS CONSOLE - PS=MANUAL PULL - SD=SMOKE DETECTOR - DD=DUCT DETECTOR - HD = HEAT DETECTOR - MM=MONITOR MODULE - CR=CONTROL RELAY - CM=CONTROL MODULE - HS = HORN/STROBE - S=STROBE ONLY - MS=MASS STROBE - SPK=SPEAKER - DH=DOOR HOLDER

BUILDING NUMBERINSPECTION TEAM

KS, AS, RR 7404

FIRE ALARM

DEVICE REPORT

SD IN CENTERAL STORAGE 142 1D47 P 2.65

SD HALL BY ROOM 143 1D46 P 2.56

SD IN ROOM 143 1D45 P 2.63

SD IN ROOM 143 1D44 P 2.34

MS-SPK-S IN ROOM 143 P

PS IN ROOM 143 1M11 P

SPK OUTSIDE ROOM 143 P

SD STORAGE ROOM 143B 1D42 P 2.64

MS-SPK-S KITCHEN 152 P

MS-SPK-S KITCHEN 152 P

HD KITCHEN 152 1D102 P

PS KITCHEN 152 1M28 P

SD KITCHEN STORAGE 152A 1D106 P 2.55

MM KITCHEN HOOD 1M27 P

SD HALL BY ROOM 146 1D103 P 2.60

SPK HALL BY ROOM 146 P

SD IN ROOM 146 1D40 P 2.61

SD IN ROOM 146 1D39 P 2.67

MS-SPK-S IN ROOM 146 P

PS IN ROOM 146 1M10 P

SD STORAGE ROOM 146B 1D43 P 2.73

MM FOR PIV IN ROOM 146 1M9 P

SD IN REST ROOM 145 BY 146 1D41 P 2.78

MS-SPK-S IN REST ROOM 145 BY 146 P

SD LAUNDRY ROOM 150 1D104 P 2.55

MS-SPK-S LAUNDRY ROOM 150 P

SD VIDEO ROOM 149 1D105 P 2.70

MS-SPK-S VIDEO ROOM 149 P

SD HALL BY ROOM 147 1D34 P 2.75

SD IN ROOM 147 1D35 P 2.86

BUILDING 7404-5YR-5-10-2021 PAGE 7 OF 9

Suite #4 Louisville, KY 40299

(502) 614-8646

Premier Fire & Security Inc.

1251 N 6th St

Paducah, KY 42002

(270) 443-7060

DATE

5/10/2021

DEVICE DEVICE LOCATION DEVICE

ADDRESS

OR

ZONE

P A

SS

FA

IL

Se ns iti vi ty

NOTES:

FA = FIRE ALARM - KF = KINGFISHER - BPS = BOOSTER POWER SUPPLY - VP=VOICE/MASS PANEL - AN=ANNUNCIATOR/MASS CONSOLE - PS=MANUAL PULL - SD=SMOKE DETECTOR - DD=DUCT DETECTOR - HD = HEAT DETECTOR - MM=MONITOR MODULE - CR=CONTROL RELAY - CM=CONTROL MODULE - HS = HORN/STROBE - S=STROBE ONLY - MS=MASS STROBE - SPK=SPEAKER - DH=DOOR HOLDER

BUILDING NUMBERINSPECTION TEAM

KS, AS, RR 7404

FIRE ALARM

DEVICE REPORT

SD IN ROOM 147 1D36 P 2.55

MS-SPK-S IN ROOM 147 P

SD IN RESTROOM IN 147 1D37 P 2.51

MS-SPK-S IN RESTROOM IN 147 P

SD STORAGE ROOM 147B 1D38 P 2.49

PS IN ROOM 147 1M8 P

SPK OUTSIDE ROOM 147 P

TS PN PIV 1M9 P

MS-SPK-S HALL BY RM 147 P

PS EXIT BY 147 1M7 P

SPK OUTSIDE BY 147 P

SPK OUTSIDE BY MECH ROOM P

TS SPRINKLER RISER 1M4 P

TS SPRINKLER RISER 1M5 P

WF SPRINKLER RISER 1M6 P

PS MECH ROOM 1M3 P

SD MECH ROOM 1D31 P 2.25

MS-SPK-S MECH ROOM P

DD MECH ROOM 1D32 P 2.97

CR AHU SHUTDOWN 1M107 P

DD MECH ROOM 1D33 P 2.64

SD ELECT ROOM 1D30 P 2.25

MS-SPK-S ELECT ROOM P

SPK OUTSIDE ELECT ROOM P

WA P

WPSR P

FDC P

INSPTEST P

PIV P

BUILDING 7404-5YR-5-10-2021 PAGE 8 OF 9

Sprinkler System Inspection

X

Yes No N/A Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A Yes No N/A

Air:Pilot:Pilot:

60 Static:System:

Air:

ANNUAL -

INSPECTION TYPE

5. Dry Pipe and Pre-action 5 Year

6. Pre-action Bi-Annual

SYSTEM TYPE

OTHER -

PRE-ACTION -

DRY PIPE -

WET PIPE -

McAuliffe WAY Fort Campbell KY 42223

5 YEAR -

2 YEAR -7404

Hydrostatic or Previous Gauge Readings

Is there a Backflow Device at the riser?

Current Gauge Readings Street: 50

Internally inspected, cleaned and free from damage?

Is air compressor in service and in

Residule:

Static:

OTHER -

Residule: 45 System: 60

Anti-freeze loops have correct solution mixture.

Does low air supply works properly?

Premier Fire & Security Inc.

1251 N 6th St

Paducah, KY 42002

(270) 443-7060

NCS

11501 Plantside Drive Suite #4 Louisville, KY 40299

(502) 614-8646

SPECIAL CONSIDERATIONS - List any unique functions to be aware of prior to testing

Are fire department caps in good condition?

Alarm test in proper position.

Does water flow devices work properly?

Is fire department connection accessible?

3. 2 Year and 5 Year Inspections:

and filled with the correct sprinkler heads?

Is sprinkler head cabinet mounted close to the riser

Are all control valves and trim in good condition?

5. Dry Pipe Bi-Annual

Trip valve, drain and clean internally Does quick opening devices work properly?

All low points drained?

All low points drained?

Are OS&Y stems lubricated?

All strainers cleaned and in proper condition.Operated valve to verify proper function?

Verified water travels through inspectors test.

Street: 50

INSPECTION DATES:

5/10/2021

Adequate heating, and on if necessary.

KS, AS, RR

INSPECTION TEAM:

Is hydrolic nameplace present and visible?

Are control valves supervised, lock or Tamper?

VALVE LOCATION

POC CONTACT INFO

BUILDING POC NAME

VALVE SIZE AND TYPE

NOTES, FAILURES AND SYSTEM DEVIATIONS FROM CONTRACT STANDARDS

Does low air supply works properly?

1.All Inspections:

BUILDING NUMBER

Verify water supply "conduct main drain test"

Gauges appear to be in working order ?

2.Annual, 2 Year and 5 Year Inspections:

ROOM 152 WALK IN HAS 2 DRY PENDENT HEADS OVER 10 YEARS OLD THAT NEED REPLACED.

ROOM 152 HAS 2 155DG CHROME PENDENT TYCO QUICK RESPONSE HEADS THAT ARE CORRODED.

MAKE

Is air pressure on the system satisfactory?

satisfactory operating condition?

Did system trip by device to verify operation?

Does quick opening devices work properly?

Did system trip by manual actuator?

MODEL NUMBER

MECH ROOM 4" CHECK 717RVICTAULIC

4. Wet Systems 5 Year Wet:

Is System in operation?

BUILDING 7404-5YR-5-10-2021 PAGE 9 OF 9

7402 As-Builts
CDC_Final_As_Builts_F-001
CDC_Final_As_Builts_F-101
CDC_Final_As_Builts_F-102
CDC_Final_As_Builts_F-601
7402_5YR_05-06-21
7404 As-Builts
CDC_MD01-F-001
References
Top, ..
..
..
..
ARC_HQF-HF-001--.dgn, Default
..
General
HNC_AnsiD-EngSht.dgn
CDC_MD01-F-101
References
scrFP, ..
..
Extractions
Architectural
CDC_MD01-EX_A-FP.dgn
CDC_MD01-FA-101
References
scrFP, ..
..
Extractions
Architectural
CDC_MD01-EX_A-FP.dgn
SCRROOM ID, ..
..
Extractions
Architectural
CDC_MD01-EX_A-ROOM NAMES2.dgn
..
General
CDC_MD01-G-KEY PLAN.dgn
HNC_AnsiD-EngSht.dgn
CDC_MD01-FP-101
CDC_MD01-FP-101

7404_5YR_05-10-21

File details come from the government source that posted it. Updated .