FA520922Q0049

Attachment 1‐2

MIL‐PRF‐680 Type II

Properties Test Methods for Inspections

Flash point °C(°F) 61‐92(141‐198) ASTM methods D56

Distillation °C ASTM methods D86

Initial boiling pt., minimum (min) 177

Dry point °C, maximum (max) 212

Kauri‐Butanol value 27 to 45 ASTM methods D1133

Aromatic content, vol %., max 1 ASTM methods D3257

Total phenol content, parts per million (ppm), max 0.5 EPA 420.1

Dichlorobenzene, milligrams per liter (mg/L) , max Benzene, mg/L, max 0.5, 0.5 EPA 3585 and 8260B

Tetrachloroethylene, mg/L, max 0.7 EPA 3585 and 8260B

Trichloroethylene, mg/L, max 0.5 EPA 3585 and 8260B

Apparent specific gravity, 60/60F 0.754 to 0.82 ASTM methods D1298

Total chlorine content (PPM), Max 100

Non‐volatile residue, (mg/100mL), max 8 ASTM methods D1353

Color, min 25 ASTM methods D156

Odor low & non‐residual ASTM methods D1296

Corrosion, copper, max 1b ASTM methods D130

Sandwich corrosion, max 1 ASTM methods F1110

Total immersion corrosion Pass ASTM methods F483

Titanium stress corrosion No cracking ASTM methods F945

Acidity Neutral ASTM methods D847

Doctor test Negative ASTM methods D235

Vapor pressure, millimeters of Mercury (mm Hg) @ 20°C, max 2 ASTM methods D2879

Soil cleaning test, %, min 85 FED‐STD‐791 Method, 7502

VOC, g/l, max NR SCAQMD 313

1516804897U Text Box Appendix B

File details come from the government source that posted it. Updated .