Atachment A_Demolition Plans.pdf

PDF 5 MB Posted

Attached to
Asbestos, Mold, Lead Paint Removal, Demolition and Debris Removal
Solicitation number
PE-66276-NONST-2024-000000010
Issued by
Ware County, Georgia

About this file

This document contains the demolition plans for the 120 & 124 S. Cherokee Road and 136 S. Cherokee Road buildings in Social Circle, Georgia. The plans outline the general demolition requirements, including the removal of existing millwork, plumbing fixtures, ceilings, and interior lighting. The existing wood floors and ceiling decks are to remain and be protected. The contractor is responsible for field verifying all existing conditions and dimensions prior to commencing demolition work. The owner will provide the testing results for asbestos-containing materials and has the right to salvage any fixtures or millwork within the demolition areas prior to the contractor starting work.

The plans also specify that the contractor must coordinate any power, communication, fire protection, and medical gas shutdowns with the owner and general contractor to ensure that portions of the building(s) that need to remain in use are not affected. The contractor is responsible for repairing any damage to existing finishes and equipment not removed under the scope of work.

View the file

Other files

File Type Posted
RFB _ Lead_Asbestos_Mold mitigation and Demo .pdf PDF
Atachment B_Bid Form.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DEMOLITION GENERAL NOTES

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

A.

B.

C.

17.

18.

19.

20.

21.

ALL ITEMS SHOWN IN A DASHED RED LINE SHALL BE REMOVED AND DISPOSED OF,

UNLESS NOTED OTHERWISE.

ALL DRAWINGS ARE GRAPHIC REPRESENTATION OF APPROXIMATE LOCATION OF

MATERIALS TO BE REMOVED. IT IS THE CONTRACTORS RESPONSIBILITY TO FIELD VERIFY

ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR TO COMMENCEMENT OF ALL

DEMOLTION WORK.

ALL EXTERIOR DOORS AND WINDOWS TO REMAIN.

CONSULT MECHANICAL, ELECTRICAL, AND PLUMBING ENGINEER FOR DEMOLITON OF

EXISTING UTILITIES, EXISTING PLUMBING FIXTURES, WATER HEATER, MECHANICAL

DUCTING, AND EXISTING SERVICES.

VERIFY WITH OWNER EXTENT OF EXISTING MECHANICAL DUCTWORK AND HVAC

EQUIPMENT TO BE REMOVED. CONSULT MECHANICAL ENGINEER FOR ASSOCIATED

HEATING AND COOLING REQUIREMENTS.

REMOVE ALL EXISTING INTERIOR LIGHTING THROUGHOUT. CONSULT ELECTRICAL

ENGINEER FOR NEW ELECTRICAL EMERGENCY LIGHTING REQUIREMENTS.

CONSULT STRUCTURAL ENGINEER TO VERIFY NO WALLS BEING REMOVED ARE LOAD

BEARING.

ALL ITEMS TO BE SALVAGED WITHIN THE DEMOLTION AREA, WILL BE REMOVED BY THE

OWNER PRIOR TO ONSET OF DEMOLITON WORK.

REMAINING SUBSTRATES SHALL BE LEFT IN A CONDITION ACCEPTABLE TO RECEIVE

NEW WORK. REMOVE EXISTING FINISHES DOWN TO SUBSTRATE AND PREPARE SURFACE

FOR NEW FINISH. EXISTING WOOD FLOORS TO REMAIN.

THE CONTRACTOR IS RESPONSIBLE FOR DAMAGE TO ANY EXISTING FINISHES AND

EQUIPMENT NOT REMOVED UNDER THE SCOPE OF WORK. ANY DAMAGE WILL BE

REPAIRED TO THE OWNER/ARCHITECT'S SATISFACTION.

POWER, COMMUNICATION, FIRE PROTECTION & MEDICAL GAS SHUT DOWNS SHALL

NOT EFFECT PORTIONS OF BUILDING(S) THAT NEED TO REMAIN IN USE. CONTRACTOR

TO REROUTE OR PROVIDE TEMPORARY POWER, COMMUNICATION, FIRE PROTECTION

AND MEDICAL GAS. COORDINATE SHUT DOWNS WITH OWNER AND GENERAL

CONTRACTOR.

REMOVE ALL EXISTING CEILINGS, UNLESS NOTED OTHERWISE ON THE DRAWINGS.

EXISTING WOOD CEILING DECK TO REMAIN AND BE PROTECTED. THE EXISTING

CEILING SHALL BE REMOVED AND REPLACED IN A MANNER TO AVOID DAMAGE TO

THE WALL SYSTEM.

NOTIFY ARCHITECT AND OWNER OF EXISTING DUCTWORK, PIPE, AND CONDUIT

PENETRATIONS EXPOSED AFTER DEMOLITION THAT ARE NOT FIRESTOPPED THROUGH

EXISTING FLOORS AND WALLS IDENTIFIED AS FIRE AND/OR SMOKE RATED ON LIFE

SAFETY PLANS. EXISTING NON-COMPLIANT PENETRATIONS ARE TO BE FIRESTOPPED.

WORK AREAS SHALL BE MAINTAINED AND ALL WORK AREAS SHALL BE LEFT BROOM

CLEANED AT END OF EACH DAY.

IN ALL LOCATIONS THAT A DOOR IS ILLUSTRATED TO BE DEMOLISHED, REMOVE AND

DISPOSE OF DOOR, FRAME, HARDWARE AND ALL ASSOCIATED ITEMS, UNLESS NOTED

OTHERWISE.

TYPICAL BUILDING COMPONENTS TO BE LEFT IN PLACE WHICH ARE NOT TO BE

DEMOLISHED, UNLESS NOTED OTHERWISE:

FIREPROOFING ON COLUMNS AND BEAMS WHICH IS NOT PART OF A WALL OR

CEILING SYSTEM. THIS INCLUDES PLASTER, MASONRY, AND CONCRETE COVERS

WHICH MAY BE ENCAPSULATED BY THE WALL OR CEILING ASSEMBLIES.

ELECTRIC, PLUMBING AND HVAC LINES FEEDING AREAS TO REMAIN IN

OPERATION. COORDINATE WITH MEP DRAWINGS.

ANY STRUCTURES UNCOVERED AS A RESULT OF DEMOLITION WHICH APPEAR TO

BE SUPPORTING IN NATURE AND REQUIRING VERIFICATION PRIOR TO

DEMOLITION. THIS INCLUDES EQUIPMENT SUPPORTS AND STRUCTURE ADDED AS

A RESULT OF PREVIOUS CONSTRUCTION OR ADDITIONS.

THE OWNER WILL REMOVE ALL MOVEABLE OR UNATTACHED ITEMS TO BE SAVED OR

STORED PRIOR TO CONTRACTORS' SALVAGE OPERATIONS. ITEMS TO BE SALVAGED

INCLUDE BUT ARE NOT LIMITED TO, THOSE ITEMS SHOWN ON THE DRAWINGS.

OWNER HAS THE RIGHT TO SALVAGE ANY FIXTURES AND/OR MILLWORK WITHIN AN

AREA OF DEMOLITION PRIOR TO CONTRACTOR STARTING WORK IN THAT ZONE.

COORDINATE TIMING OF SUCH REMOVALS WITH OWNER.

RECONSTRUCT EXISTING FIREPROOFING DUE TO WALL, CEILING OR EQUIPMENT

DEMOLITION.

THE OWNER WILL PROVIDE THE TESTING RESULTS OF ASBESTOS CONTAINING MATERIALS

(ACM) IN THE PROJECT AREA. IN THE CASE THAT ANY SUSPICIOUS MATERIALS ARE

UNCOVERED OR QUESTIONED, LEAVE THE PREMISES AND NOTIFY THE OWNER &

ABATEMENT CONTRACTOR FOR REQUIRED TESTING AND/OR REMOVALS.

DESIGNER NOTE: VERIFY ABATEMENT SCOPE.

IN THE CASE THAT ANY SUSPICIOUS MATERIALS ARE UNCOVERED THAT APPEAR TO

CONTAIN HAZARDOUS MATERIALS SUCH AS BUT NOT LIMITED TO MOLD, LEAD PAINT

OR ASBESTOS, LEAVE THE PREMISES AND NOTIFY THE OWNER & ABATEMENT

CONTRACTOR FOR REQUIRED TESTING AND/OR REMOVALS.

120 S. Cherokee Road - 3960 SF 124 S. Cherokee Road - 3220 SF

OVERALL SPACE AREA

DEMOLITION KEYED NOTES

1 REMOVE ALL EXISTING MILLWORK AND ASSOCIATED PLUMBING.

F1 EXISTING WOOD FLOOR TO REMAIN.

F2 EXISTING CONCRETE FLOOR TO REMAIN.

2 REMOVE AND CAP ALL EXISTING PLUMBING FIXTURES. VERIFY DEMOLITION

REQUIREMENTS WITH PLUMBING ENGINEER.

3 EXISTING SKYLIGHTS AND ASSOCIATED WOOD CEILINGS TO REMAIN.

A

DEMISING WALL TO REMAIN

F1 F1

F2

F1

DEMOLITION FLOOR PLAN LEGEND

DEMOLISH ALL CARPET AND TILE

FLOORING. ALL EXISTING WOOD

AND CONCRETE FLOOR TO REMAIN.

DEMOLISH ALL INTERIOR WALLS

THROUGHOUT. VERIFY NONE ARE

LOADED WITH STRUCTURAL ENGINEER.

EXISTING

1/8" = 1'-0"A101

1 FIRST FLOOR DEMOLITION PLAN

400 Bellemeade Street Suite 401, Greensboro, NC 27401

CPL | Architecture Engineering Planning

CPLteam.com

Client Name

Project Address

PROJECT INFORMATION

Project Name

Project Number

Drawing Title

Drawn By

SHEET INFORMATION

Checked By

Drawing Number

Issued Scale

Project Status

PROFESSIONAL STAMPS

8/

/2

:4 0:

P

M

As indicated

PR

O

JE

C

T F

ILE

S O N

AC

C

City of Social Circle

120 & 124 S. Cherokee Road Social Circle, GA 30025

Social Circle Downtown Building Demolition

R23.01470.00 Phase 00002

DEMOLTION PLAN

CPL CPL

08/27/2024

DESIGN

A101

PROJECT ISSUE & REVISION SCHEDULE

# Date Description 08/27/2024 Architectural Demoiltion Package#1 Demolition

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

A.

B.

C.

17.

18.

19.

20.

21.

ALL ITEMS SHOWN IN A DASHED RED LINE SHALL BE REMOVED AND DISPOSED OF,

UNLESS NOTED OTHERWISE.

ALL DRAWINGS ARE GRAPHIC REPRESENTATION OF APPROXIMATE LOCATION OF

MATERIALS TO BE REMOVED. IT IS THE CONTRACTORS RESPONSIBILITY TO FIELD VERIFY

ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR TO COMMENCEMENT OF ALL

DEMOLTION WORK.

ALL EXTERIOR DOORS AND WINDOWS TO REMAIN.

CONSULT MECHANICAL, ELECTRICAL, AND PLUMBING ENGINEER FOR DEMOLITON OF

EXISTING UTILITIES, EXISTING PLUMBING FIXTURES, WATER HEATER, MECHANICAL

DUCTING, AND EXISTING SERVICES.

VERIFY WITH OWNER EXTENT OF EXISTING MECHANICAL DUCTWORK AND HVAC

EQUIPMENT TO BE REMOVED. CONSULT MECHANICAL ENGINEER FOR ASSOCIATED

HEATING AND COOLING REQUIREMENTS.

REMOVE ALL EXISTING INTERIOR LIGHTING THROUGHOUT. CONSULT ELECTRICAL

ENGINEER FOR NEW ELECTRICAL EMERGENCY LIGHTING REQUIREMENTS.

CONSULT STRUCTURAL ENGINEER TO VERIFY NO WALLS BEING REMOVED ARE LOAD

BEARING.

ALL ITEMS TO BE SALVAGED WITHIN THE DEMOLTION AREA, WILL BE REMOVED BY THE

OWNER PRIOR TO ONSET OF DEMOLITON WORK.

REMAINING SUBSTRATES SHALL BE LEFT IN A CONDITION ACCEPTABLE TO RECEIVE

NEW WORK. REMOVE EXISTING FINISHES DOWN TO SUBSTRATE AND PREPARE SURFACE

FOR NEW FINISH. EXISTING WOOD FLOORS TO REMAIN.

THE CONTRACTOR IS RESPONSIBLE FOR DAMAGE TO ANY EXISTING FINISHES AND

EQUIPMENT NOT REMOVED UNDER THE SCOPE OF WORK. ANY DAMAGE WILL BE

REPAIRED TO THE OWNER/ARCHITECT'S SATISFACTION.

POWER, COMMUNICATION, FIRE PROTECTION & MEDICAL GAS SHUT DOWNS SHALL

NOT EFFECT PORTIONS OF BUILDING(S) THAT NEED TO REMAIN IN USE. CONTRACTOR

TO REROUTE OR PROVIDE TEMPORARY POWER, COMMUNICATION, FIRE PROTECTION

AND MEDICAL GAS. COORDINATE SHUT DOWNS WITH OWNER AND GENERAL

CONTRACTOR.

REMOVE ALL EXISTING CEILINGS, UNLESS NOTED OTHERWISE ON THE DRAWINGS.

EXISTING WOOD CEILING DECK TO REMAIN AND BE PROTECTED. THE EXISTING

CEILING SHALL BE REMOVED AND REPLACED IN A MANNER TO AVOID DAMAGE TO

THE WALL SYSTEM.

NOTIFY ARCHITECT AND OWNER OF EXISTING DUCTWORK, PIPE, AND CONDUIT

PENETRATIONS EXPOSED AFTER DEMOLITION THAT ARE NOT FIRESTOPPED THROUGH

EXISTING FLOORS AND WALLS IDENTIFIED AS FIRE AND/OR SMOKE RATED ON LIFE

SAFETY PLANS. EXISTING NON-COMPLIANT PENETRATIONS ARE TO BE FIRESTOPPED.

WORK AREAS SHALL BE MAINTAINED AND ALL WORK AREAS SHALL BE LEFT BROOM

CLEANED AT END OF EACH DAY.

IN ALL LOCATIONS THAT A DOOR IS ILLUSTRATED TO BE DEMOLISHED, REMOVE AND

DISPOSE OF DOOR, FRAME, HARDWARE AND ALL ASSOCIATED ITEMS, UNLESS NOTED

OTHERWISE.

TYPICAL BUILDING COMPONENTS TO BE LEFT IN PLACE WHICH ARE NOT TO BE

DEMOLISHED, UNLESS NOTED OTHERWISE:

FIREPROOFING ON COLUMNS AND BEAMS WHICH IS NOT PART OF A WALL OR

CEILING SYSTEM. THIS INCLUDES PLASTER, MASONRY, AND CONCRETE COVERS

WHICH MAY BE ENCAPSULATED BY THE WALL OR CEILING ASSEMBLIES.

ELECTRIC, PLUMBING AND HVAC LINES FEEDING AREAS TO REMAIN IN

OPERATION. COORDINATE WITH MEP DRAWINGS.

ANY STRUCTURES UNCOVERED AS A RESULT OF DEMOLITION WHICH APPEAR TO

BE SUPPORTING IN NATURE AND REQUIRING VERIFICATION PRIOR TO

DEMOLITION. THIS INCLUDES EQUIPMENT SUPPORTS AND STRUCTURE ADDED AS

A RESULT OF PREVIOUS CONSTRUCTION OR ADDITIONS.

THE OWNER WILL REMOVE ALL MOVEABLE OR UNATTACHED ITEMS TO BE SAVED OR

STORED PRIOR TO CONTRACTORS' SALVAGE OPERATIONS. ITEMS TO BE SALVAGED

INCLUDE BUT ARE NOT LIMITED TO, THOSE ITEMS SHOWN ON THE DRAWINGS.

OWNER HAS THE RIGHT TO SALVAGE ANY FIXTURES AND/OR MILLWORK WITHIN AN

AREA OF DEMOLITION PRIOR TO CONTRACTOR STARTING WORK IN THAT ZONE.

COORDINATE TIMING OF SUCH REMOVALS WITH OWNER.

RECONSTRUCT EXISTING FIREPROOFING DUE TO WALL, CEILING OR EQUIPMENT

DEMOLITION.

THE OWNER WILL PROVIDE THE TESTING RESULTS OF ASBESTOS CONTAINING MATERIALS

(ACM) IN THE PROJECT AREA. IN THE CASE THAT ANY SUSPICIOUS MATERIALS ARE

UNCOVERED OR QUESTIONED, LEAVE THE PREMISES AND NOTIFY THE OWNER &

ABATEMENT CONTRACTOR FOR REQUIRED TESTING AND/OR REMOVALS.

DESIGNER NOTE: VERIFY ABATEMENT SCOPE.

IN THE CASE THAT ANY SUSPICIOUS MATERIALS ARE UNCOVERED THAT APPEAR TO

CONTAIN HAZARDOUS MATERIALS SUCH AS BUT NOT LIMITED TO MOLD, LEAD PAINT

OR ASBESTOS, LEAVE THE PREMISES AND NOTIFY THE OWNER & ABATEMENT

CONTRACTOR FOR REQUIRED TESTING AND/OR REMOVALS.

120 S. Cherokee Road - 3960 SF 124 S. Cherokee Road - 3220 SF

OVERALL SPACE AREA

DEMOLITION KEYED NOTES

1 REMOVE ALL EXISTING MILLWORK AND ASSOCIATED PLUMBING.

F1 EXISTING WOOD FLOOR TO REMAIN.

F2 EXISTING CONCRETE FLOOR TO REMAIN.

2 REMOVE AND CAP ALL EXISTING PLUMBING FIXTURES. VERIFY DEMOLITION

REQUIREMENTS WITH PLUMBING ENGINEER.

3 EXISTING SKYLIGHTS AND ASSOCIATED WOOD CEILINGS TO REMAIN.

A

C2

DEMOLITION CEILING LEGEND

DEMOLISH LAY-IN CEILING AND

ASSOCIATED LIGHTS, VENTS AND

CEILING FANS

DEMOLISH DRYWALL CEILING AND

ASSOCIATED LIGHTS, VENTS AND

CEILING FANS

*UNO. REMOVE ALL EXISTING CEILING.

PRESERVE AND PROTECT ALL EXISTING

WOOD CEILING DECK THROUGHOUT.

EXISTING

400 Bellemeade Street Suite 401, Greensboro, NC 27401

CPL | Architecture Engineering Planning

CPLteam.com

Client Name

Project Address

PROJECT INFORMATION

Project Name

Project Number

Drawing Title

Drawn By

SHEET INFORMATION

Checked By

Drawing Number

Issued Scale

Project Status

PROFESSIONAL STAMPS

8/

/2

:4 0:

P

M

As indicated

PR

O

JE

C

T F

ILE

S O N

AC

C

City of Social Circle

120 & 124 S. Cherokee Road Social Circle, GA 30025

Social Circle Downtown Building Demolition

R23.01470.00 Phase 00002

DEMOLTION REFLECTED CEILING

PLAN

CPL CPL

08/27/2024

DESIGN

A102

1/8" = 1'-0"A102

1 FIRST FLOOR DEMOLITION REFLECTED CEILING PLAN

# Date Description 08/27/2024 Architectural Demolition Package#1

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

A.

B.

C.

17.

18.

19.

20.

21.

ALL ITEMS SHOWN IN A DASHED RED LINE SHALL BE REMOVED AND DISPOSED OF,

UNLESS NOTED OTHERWISE.

ALL DRAWINGS ARE GRAPHIC REPRESENTATION OF APPROXIMATE LOCATION OF

MATERIALS TO BE REMOVED. IT IS THE CONTRACTORS RESPONSIBILITY TO FIELD VERIFY

ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR TO COMMENCEMENT OF ALL

DEMOLTION WORK.

ALL EXTERIOR DOORS AND WINDOWS TO REMAIN.

CONSULT MECHANICAL, ELECTRICAL, AND PLUMBING ENGINEER FOR DEMOLITON OF

EXISTING UTILITIES, EXISTING PLUMBING FIXTURES, WATER HEATER, MECHANICAL

DUCTING, AND EXISTING SERVICES.

VERIFY WITH OWNER EXTENT OF EXISTING MECHANICAL DUCTWORK AND HVAC

EQUIPMENT TO BE REMOVED. CONSULT MECHANICAL ENGINEER FOR ASSOCIATED

HEATING AND COOLING REQUIREMENTS.

REMOVE ALL EXISTING INTERIOR LIGHTING THROUGHOUT. CONSULT ELECTRICAL

ENGINEER FOR NEW ELECTRICAL EMERGENCY LIGHTING REQUIREMENTS.

CONSULT STRUCTURAL ENGINEER TO VERIFY NO WALLS BEING REMOVED ARE LOAD

BEARING.

ALL ITEMS TO BE SALVAGED WITHIN THE DEMOLTION AREA, WILL BE REMOVED BY THE

OWNER PRIOR TO ONSET OF DEMOLITON WORK.

REMAINING SUBSTRATES SHALL BE LEFT IN A CONDITION ACCEPTABLE TO RECEIVE

NEW WORK. REMOVE EXISTING FINISHES DOWN TO SUBSTRATE AND PREPARE SURFACE

FOR NEW FINISH. EXISTING WOOD FLOORS TO REMAIN.

THE CONTRACTOR IS RESPONSIBLE FOR DAMAGE TO ANY EXISTING FINISHES AND

EQUIPMENT NOT REMOVED UNDER THE SCOPE OF WORK. ANY DAMAGE WILL BE

REPAIRED TO THE OWNER/ARCHITECT'S SATISFACTION.

POWER, COMMUNICATION, FIRE PROTECTION & MEDICAL GAS SHUT DOWNS SHALL

NOT EFFECT PORTIONS OF BUILDING(S) THAT NEED TO REMAIN IN USE. CONTRACTOR

TO REROUTE OR PROVIDE TEMPORARY POWER, COMMUNICATION, FIRE PROTECTION

AND MEDICAL GAS. COORDINATE SHUT DOWNS WITH OWNER AND GENERAL

CONTRACTOR.

REMOVE ALL EXISTING CEILINGS, UNLESS NOTED OTHERWISE ON THE DRAWINGS.

EXISTING WOOD CEILING DECK TO REMAIN AND BE PROTECTED. THE EXISTING

CEILING SHALL BE REMOVED AND REPLACED IN A MANNER TO AVOID DAMAGE TO

THE WALL SYSTEM.

NOTIFY ARCHITECT AND OWNER OF EXISTING DUCTWORK, PIPE, AND CONDUIT

PENETRATIONS EXPOSED AFTER DEMOLITION THAT ARE NOT FIRESTOPPED THROUGH

EXISTING FLOORS AND WALLS IDENTIFIED AS FIRE AND/OR SMOKE RATED ON LIFE

SAFETY PLANS. EXISTING NON-COMPLIANT PENETRATIONS ARE TO BE FIRESTOPPED.

WORK AREAS SHALL BE MAINTAINED AND ALL WORK AREAS SHALL BE LEFT BROOM

CLEANED AT END OF EACH DAY.

IN ALL LOCATIONS THAT A DOOR IS ILLUSTRATED TO BE DEMOLISHED, REMOVE AND

DISPOSE OF DOOR, FRAME, HARDWARE AND ALL ASSOCIATED ITEMS, UNLESS NOTED

OTHERWISE.

TYPICAL BUILDING COMPONENTS TO BE LEFT IN PLACE WHICH ARE NOT TO BE

DEMOLISHED, UNLESS NOTED OTHERWISE:

FIREPROOFING ON COLUMNS AND BEAMS WHICH IS NOT PART OF A WALL OR

CEILING SYSTEM. THIS INCLUDES PLASTER, MASONRY, AND CONCRETE COVERS

WHICH MAY BE ENCAPSULATED BY THE WALL OR CEILING ASSEMBLIES.

ELECTRIC, PLUMBING AND HVAC LINES FEEDING AREAS TO REMAIN IN

OPERATION. COORDINATE WITH MEP DRAWINGS.

ANY STRUCTURES UNCOVERED AS A RESULT OF DEMOLITION WHICH APPEAR TO

BE SUPPORTING IN NATURE AND REQUIRING VERIFICATION PRIOR TO

DEMOLITION. THIS INCLUDES EQUIPMENT SUPPORTS AND STRUCTURE ADDED AS

A RESULT OF PREVIOUS CONSTRUCTION OR ADDITIONS.

THE OWNER WILL REMOVE ALL MOVEABLE OR UNATTACHED ITEMS TO BE SAVED OR

STORED PRIOR TO CONTRACTORS' SALVAGE OPERATIONS. ITEMS TO BE SALVAGED

INCLUDE BUT ARE NOT LIMITED TO, THOSE ITEMS SHOWN ON THE DRAWINGS.

OWNER HAS THE RIGHT TO SALVAGE ANY FIXTURES AND/OR MILLWORK WITHIN AN

AREA OF DEMOLITION PRIOR TO CONTRACTOR STARTING WORK IN THAT ZONE.

COORDINATE TIMING OF SUCH REMOVALS WITH OWNER.

RECONSTRUCT EXISTING FIREPROOFING DUE TO WALL, CEILING OR EQUIPMENT

DEMOLITION.

THE OWNER WILL PROVIDE THE TESTING RESULTS OF ASBESTOS CONTAINING MATERIALS

(ACM) IN THE PROJECT AREA. IN THE CASE THAT ANY SUSPICIOUS MATERIALS ARE

UNCOVERED OR QUESTIONED, LEAVE THE PREMISES AND NOTIFY THE OWNER &

ABATEMENT CONTRACTOR FOR REQUIRED TESTING AND/OR REMOVALS.

DESIGNER NOTE: VERIFY ABATEMENT SCOPE.

IN THE CASE THAT ANY SUSPICIOUS MATERIALS ARE UNCOVERED THAT APPEAR TO

CONTAIN HAZARDOUS MATERIALS SUCH AS BUT NOT LIMITED TO MOLD, LEAD PAINT

OR ASBESTOS, LEAVE THE PREMISES AND NOTIFY THE OWNER & ABATEMENT

CONTRACTOR FOR REQUIRED TESTING AND/OR REMOVALS.

136 S Cherokee Road - 2222 SF

OVERALL SPACE AREA

DEMOLITION KEYED NOTES

1 REMOVE AND CAP EXISTING PLUMBING FIXTURES. REMOVE EXISTING WATER

HEATER ON MEZZANINE. VERIFY DEMOLITION REQUIREMENTS WITH PLUMBING

ENGINEER.

C1 REMOVE EXISTING CEILING.

C2 REMOVE ALL INTERIOR LIGHTING. CONSULT ELECTRICAL ENGINEER AND

OWNER FOR NEW EMERGENCY LIGHTING.

2 REMOVE AND REPLACE EXISTING CANOPY FABRIC. EXISTING CANOPY

STRUCTURE TO REMAIN.

3 KEEP AND PROTECT EXISTING STAINED GLASS ABOVE ENTRY IN INTERIOR.

F1 REMOVE EXISTING FLOOR AND INCLUDE NEW 4" GRAVEL INFILL FLOORING

THROUGHOUT FOR FUTURE CONCRETE FLOOR UPFIT.

A

F1

DEMOLITION LEGEND

DEMOLISHED

EXISTING TO REMAIN

1/8" = 1'-0"A101

1 FIRST FLOOR DEMOLITION PLAN

400 Bellemeade Street Suite 401, Greensboro, NC 27401

CPL | Architecture Engineering Planning

CPLteam.com

Client Name

Project Address

PROJECT INFORMATION

Project Name

Project Number

Drawing Title

Drawn By

SHEET INFORMATION

Checked By

Drawing Number

Issued Scale

Project Status

PROFESSIONAL STAMPS

8/

/2

:4 0:

P

M

As indicated

PR

O

JE

C

T F

ILE

S O N

AC

C

City of Social Circle

136 S. Cherokee Road Social Circle, GA 30025

Social Circle Downtown Building Demolition

R23.01470.00 Phase 00002

DEMOLITION PLAN

CPL CPL

08/27/2024

DESIGN

A101

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

A.

B.

C.

17.

18.

19.

20.

21.

ALL ITEMS SHOWN IN A DASHED RED LINE SHALL BE REMOVED AND DISPOSED OF,

UNLESS NOTED OTHERWISE.

ALL DRAWINGS ARE GRAPHIC REPRESENTATION OF APPROXIMATE LOCATION OF

MATERIALS TO BE REMOVED. IT IS THE CONTRACTORS RESPONSIBILITY TO FIELD VERIFY

ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR TO COMMENCEMENT OF ALL

DEMOLTION WORK.

ALL EXTERIOR DOORS AND WINDOWS TO REMAIN.

CONSULT MECHANICAL, ELECTRICAL, AND PLUMBING ENGINEER FOR DEMOLITON OF

EXISTING UTILITIES, EXISTING PLUMBING FIXTURES, WATER HEATER, MECHANICAL

DUCTING, AND EXISTING SERVICES.

VERIFY WITH OWNER EXTENT OF EXISTING MECHANICAL DUCTWORK AND HVAC

EQUIPMENT TO BE REMOVED. CONSULT MECHANICAL ENGINEER FOR ASSOCIATED

HEATING AND COOLING REQUIREMENTS.

REMOVE ALL EXISTING INTERIOR LIGHTING THROUGHOUT. CONSULT ELECTRICAL

ENGINEER FOR NEW ELECTRICAL EMERGENCY LIGHTING REQUIREMENTS.

CONSULT STRUCTURAL ENGINEER TO VERIFY NO WALLS BEING REMOVED ARE LOAD

BEARING.

ALL ITEMS TO BE SALVAGED WITHIN THE DEMOLTION AREA, WILL BE REMOVED BY THE

OWNER PRIOR TO ONSET OF DEMOLITON WORK.

REMAINING SUBSTRATES SHALL BE LEFT IN A CONDITION ACCEPTABLE TO RECEIVE

NEW WORK. REMOVE EXISTING FINISHES DOWN TO SUBSTRATE AND PREPARE SURFACE

FOR NEW FINISH. EXISTING WOOD FLOORS TO REMAIN.

THE CONTRACTOR IS RESPONSIBLE FOR DAMAGE TO ANY EXISTING FINISHES AND

EQUIPMENT NOT REMOVED UNDER THE SCOPE OF WORK. ANY DAMAGE WILL BE

REPAIRED TO THE OWNER/ARCHITECT'S SATISFACTION.

POWER, COMMUNICATION, FIRE PROTECTION & MEDICAL GAS SHUT DOWNS SHALL

NOT EFFECT PORTIONS OF BUILDING(S) THAT NEED TO REMAIN IN USE. CONTRACTOR

TO REROUTE OR PROVIDE TEMPORARY POWER, COMMUNICATION, FIRE PROTECTION

AND MEDICAL GAS. COORDINATE SHUT DOWNS WITH OWNER AND GENERAL

CONTRACTOR.

REMOVE ALL EXISTING CEILINGS, UNLESS NOTED OTHERWISE ON THE DRAWINGS.

EXISTING WOOD CEILING DECK TO REMAIN AND BE PROTECTED. THE EXISTING

CEILING SHALL BE REMOVED AND REPLACED IN A MANNER TO AVOID DAMAGE TO

THE WALL SYSTEM.

NOTIFY ARCHITECT AND OWNER OF EXISTING DUCTWORK, PIPE, AND CONDUIT

PENETRATIONS EXPOSED AFTER DEMOLITION THAT ARE NOT FIRESTOPPED THROUGH

EXISTING FLOORS AND WALLS IDENTIFIED AS FIRE AND/OR SMOKE RATED ON LIFE

SAFETY PLANS. EXISTING NON-COMPLIANT PENETRATIONS ARE TO BE FIRESTOPPED.

WORK AREAS SHALL BE MAINTAINED AND ALL WORK AREAS SHALL BE LEFT BROOM

CLEANED AT END OF EACH DAY.

IN ALL LOCATIONS THAT A DOOR IS ILLUSTRATED TO BE DEMOLISHED, REMOVE AND

DISPOSE OF DOOR, FRAME, HARDWARE AND ALL ASSOCIATED ITEMS, UNLESS NOTED

OTHERWISE.

TYPICAL BUILDING COMPONENTS TO BE LEFT IN PLACE WHICH ARE NOT TO BE

DEMOLISHED, UNLESS NOTED OTHERWISE:

FIREPROOFING ON COLUMNS AND BEAMS WHICH IS NOT PART OF A WALL OR

CEILING SYSTEM. THIS INCLUDES PLASTER, MASONRY, AND CONCRETE COVERS

WHICH MAY BE ENCAPSULATED BY THE WALL OR CEILING ASSEMBLIES.

ELECTRIC, PLUMBING AND HVAC LINES FEEDING AREAS TO REMAIN IN

OPERATION. COORDINATE WITH MEP DRAWINGS.

ANY STRUCTURES UNCOVERED AS A RESULT OF DEMOLITION WHICH APPEAR TO

BE SUPPORTING IN NATURE AND REQUIRING VERIFICATION PRIOR TO

DEMOLITION. THIS INCLUDES EQUIPMENT SUPPORTS AND STRUCTURE ADDED AS

A RESULT OF PREVIOUS CONSTRUCTION OR ADDITIONS.

THE OWNER WILL REMOVE ALL MOVEABLE OR UNATTACHED ITEMS TO BE SAVED OR

STORED PRIOR TO CONTRACTORS' SALVAGE OPERATIONS. ITEMS TO BE SALVAGED

INCLUDE BUT ARE NOT LIMITED TO, THOSE ITEMS SHOWN ON THE DRAWINGS.

OWNER HAS THE RIGHT TO SALVAGE ANY FIXTURES AND/OR MILLWORK WITHIN AN

AREA OF DEMOLITION PRIOR TO CONTRACTOR STARTING WORK IN THAT ZONE.

COORDINATE TIMING OF SUCH REMOVALS WITH OWNER.

RECONSTRUCT EXISTING FIREPROOFING DUE TO WALL, CEILING OR EQUIPMENT

DEMOLITION.

THE OWNER WILL PROVIDE THE TESTING RESULTS OF ASBESTOS CONTAINING MATERIALS

(ACM) IN THE PROJECT AREA. IN THE CASE THAT ANY SUSPICIOUS MATERIALS ARE

UNCOVERED OR QUESTIONED, LEAVE THE PREMISES AND NOTIFY THE OWNER &

ABATEMENT CONTRACTOR FOR REQUIRED TESTING AND/OR REMOVALS.

DESIGNER NOTE: VERIFY ABATEMENT SCOPE.

IN THE CASE THAT ANY SUSPICIOUS MATERIALS ARE UNCOVERED THAT APPEAR TO

CONTAIN HAZARDOUS MATERIALS SUCH AS BUT NOT LIMITED TO MOLD, LEAD PAINT

OR ASBESTOS, LEAVE THE PREMISES AND NOTIFY THE OWNER & ABATEMENT

CONTRACTOR FOR REQUIRED TESTING AND/OR REMOVALS.

136 S Cherokee Road - 2222 SF

OVERALL SPACE AREA

DEMOLITION KEYED NOTES

1 REMOVE AND CAP EXISTING PLUMBING FIXTURES. REMOVE EXISTING WATER

HEATER ON MEZZANINE. VERIFY DEMOLITION REQUIREMENTS WITH PLUMBING

ENGINEER.

C1 REMOVE EXISTING CEILING.

C2 REMOVE ALL INTERIOR LIGHTING. CONSULT ELECTRICAL ENGINEER AND

OWNER FOR NEW EMERGENCY LIGHTING.

2 REMOVE AND REPLACE EXISTING CANOPY FABRIC. EXISTING CANOPY

STRUCTURE TO REMAIN.

3 KEEP AND PROTECT EXISTING STAINED GLASS ABOVE ENTRY IN INTERIOR.

F1 REMOVE EXISTING FLOOR AND INCLUDE NEW 4" GRAVEL INFILL FLOORING

THROUGHOUT FOR FUTURE CONCRETE FLOOR UPFIT.

DEMOLITION LEGEND

DEMOLISHED

EXISTING TO REMAIN

A

C1

C1

C2

C2 C2

C2 C2

C2

C2

C2

400 Bellemeade Street Suite 401, Greensboro, NC 27401

CPL | Architecture Engineering Planning

CPLteam.com

Client Name

Project Address

PROJECT INFORMATION

Project Name

Project Number

Drawing Title

Drawn By

SHEET INFORMATION

Checked By

Drawing Number

Issued Scale

Project Status

PROFESSIONAL STAMPS

8/

/2

:4 0:

P

M

As indicated

PR

O

JE

C

T F

ILE

S O N

AC

C

City of Social Circle

136 S. Cherokee Road Social Circle, GA 30025

Social Circle Downtown Building Demolition

R23.01470.00 Phase 00002

DEMOLITION REFLECTED CEILING

PLAN

CPL CPL

08/27/2024

DESIGN

A102

1/8" = 1'-0"A102

1 FIRST FLOOR DEMOLITION REFLECTED CEILING PLAN

2024-08-27_Social Circle_120 Cherokee_Demolition Plans.pdf
A101 - DEMOLTION PLAN
A102 - DEMOLTION REFLECTED CEILING PLAN
2024-08-27_Social Circle_136 Cherokee_Demolition Plans.pdf
A101 - DEMOLITION PLAN
A102 - DEMOLITION REFLECTED CEILING PLAN

File details come from the government source that posted it. Updated .