ASHE171038 - Fac. 1467 AFN _CCEB FY24.xlsx
XLSX spreadsheet 91 KB Posted
- Solicitation number
- FA568224R0002
About this file
This document provides a pre-solicitation notice and scope of work for project ASHE 17-1038 CNLSD-DEMO FAC 1467 for AFN Aviano AB, Italy. The project involves demolition and removal work at Facility 1467 for the Armed Forces Network in Area F of Aviano Air Base in Italy. Interested vendors must possess a current Statement of Capabilities certification in category OG01 - Construction. The estimated value of construction is between $1,000,000 to $5,000,000. A site visit will be scheduled for interested vendors to inspect the work location. The solicitation is expected to be issued in January 2024. The selected contractor will be responsible for performing all necessary quantities of work to deliver a complete project as defined in the scope of work.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ASHE 17-1038
| GOVERNMENT COST ESTIMATE BREAKDOWN | |
| CONTRACTOR | ADDRESS |
| CONTRACT FOR (Work to be performed) | PROPOSED TOTAL CONTRACT PRICE | |||||||||
| DESIGN FOR REPAIR FAC.1467 FOR AFN AVIANO, AREA F, AVIANO AB, ITALY | ||||||||||
| PURCHASE REQUEST NUMBER | PROJECT NUMBER | WORK LOCATION | ||||||||
| ASHE 17-1038 | AREA "F", AVIANO AIR BASE, ITALY | |||||||||
| MATERIAL COSTS | LABOR COSTS | |||||||||
| LINE NO. | ITEM | UNIT OF MEASURE | QUANTITY | UNIT | TOTAL | MANHOURS MANDAYS | AVERAGE RATE | TOTAL | OTHER DIRECT COSTS | LINE TOTAL |
| (1) | (2) | (3) | (4) | (5) | (6) | (7) | (8) | (9) | (10) |
| A. | REPAIR WORKS / Lavori di Ristrutturazione | ||||||||
| PART I - DEMOLITIONS AND REMOVALS / Parte I - Demolizioni e Rimozioni | |||||||||
| Ia Civil Demolition - Ia Demolizioni Civili | |||||||||
| 1 | REMOVE AND STACK EXISTING PAVERS | ||||||||
| Rimozione ed accatastamento di betonelle esistenti | IT. No. Art. n. | 1 | SM/MQ | 0.00 | 0.00 | ||||
| 2 | REMOVAL AND STACK THE PRECAST CONCRETE PLATES | ||||||||
| Rimozione ed accatastamento di piastre prefabbricate in calcestruzzo | IT. No. Art. n. | 2 | EA/NO | 0.00 | 0.00 | ||||
| 3 | REMOVAL AND DISPOSAL OF STEEL RAILING, INCLUDING THE CONCRETE BEAM DEMOLITION | ||||||||
| Rimozione e smaltimento di parapetto in acciaio esistente, inclusa demolizione della trave di calcestruzzo | IT. No. Art. n. | 3 | LM/ML | 0.00 | 0.00 | 0.00 | |||
| 4 | FOUNDATION EXCAVATIONS (TRENCH) | ||||||||
| Scavo di fondazione a sezione obbligata | IT. No. Art. n. | 4a | CM/MC | 0.00 | 0.00 | 0.00 | |||
| 5 | TRENCH EXCAVATION FOR NEW CONDUITS | ||||||||
| Scavo in trincea per nuove condutture | IT. No. Art. n. | 4b | CM/MC | 0.00 | 0.00 | ||||
| 6 | TRANSPORTATION AND DISPOSAL (AUTHORIZED LANDFILL) OF EXCEEDING EXCAVATED SOIL | ||||||||
| Trasporto e conferimento a discarica autorizzata di materiale di scavo in eccesso | IT. No. Art. n. | 4c | CM/MC | 0.00 | 0.00 | 0.00 | |||
| 7 | REUSE OF EXCAVATED SOIL | ||||||||
| Riutilizzo di materiale scavato | IT. No. Art. n. | 4d | CM/MC | 0.00 | 0.00 | 0.00 | |||
| Total Civil Demolitions - Totale Demolizioni Civili | 0.00 | 0.00 | 0.00 | 0.00 |
| Ib Architectural Demolition - Ib Demolizioni Architettoniche | ||||||||
| 8 | SANITARY FIXTURES REMOVAL | |||||||
| Rimozione di sanitari | IT. No. Art. n. | 1 | EA/NO | 0.00 | 0.00 | |||
| 9 | REMOVAL OF TILES ICLUDED BASEBOARD AND SLAB | |||||||
| Rimozione piastrelle incluso battiscopa e sottofondo | IT. No. Art. n. | 2 | SM/MQ | 0.00 | 0.00 | |||
| 10 | REMOVAL AND DISPOSAL OF SUSPENDED CEILING | |||||||
| Demolizione rimozione e smaltimento di controsoffitto in fibre minerali | IT. No. Art. n. | 3 | SM/MQ | 0.00 | 0.00 | |||
| 11 | REMOVAL OF EXISTING EXTERNAL DOORS/WINDOWS | |||||||
| Rimozione di porte e finestre esterne esistenti | IT. No. Art. n. | 4a | SM/MQ | 0.00 | 0.00 | |||
| 12 | REMOVAL OF DOOR SILLS AND WINDOW SILLS | |||||||
| Rimozione di soglie e davanzali | IT. No. Art. n. | 4b | M/M | 0.00 | 0.00 | |||
| 12 | REMOVAL OF EXISTING INTERIOR DOORS | |||||||
| Rimozione di porte interne esistenti | IT. No. Art. n. | 5 | SM/MQ | 0.00 | 0.00 | |||
| 13 | REMOVAL OF EXISTING GYPSUM BOARD PARTITION | |||||||
| Rimozione di tramezzature in cartongesso esistenti | IT. No. Art. n. | 6a | SM/MQ | 0.00 | 0.00 | |||
| 14 | REMOVAL OF EXISTING GYPSUM BOARD COUNTERWALL | |||||||
| Rimozione di contropareti in cartongesso esistenti | IT. No. Art. n. | 6b | SM/MQ | 0.00 | 0.00 | |||
| 15 | CUT AND REMOVAL OF EXISTING POLYSTYRENE THICK.5+5cm | |||||||
| Taglio e rimozione di polistirtene esistente sp. 5+5cm | IT. No. Art. n. | 6c | SM/MQ | 0.00 | 0.00 | |||
| 16 | DEMOLITION OF EXISTING MASONRY WALLS | |||||||
| Demolizione di muri esistenti in muratura | IT. No. Art. n. | 7 | SM/MQ | 0.00 | 0.00 | |||
| 17 | REMOVAL OF DOWNSPOUT , FLASHING AND GUTTERS | |||||||
| Rimozione di pluviali lattonerie e gronde | IT. No. Art. n. | 8a | LM/ML | 0.00 | 0.00 | |||
| 18 | REMOVAL AND DISPOSAL OF EXISTING MEMBRANE IN COVERAGE | |||||||
| Rimozione e smaltimento di guaina in copertura | IT. No. Art. n. | 8b | SM/MQ | 0.00 | 0.00 | |||
| Total Architectural Demolition - Totale Demolizioni Architettoniche | 0.00 | 0.00 | 0.00 | 0.00 |
| Ic Structural Demolition - Ic Demolizioni Strutturali | ||||||||
| 19 | FOUNDATION EXCAVATION INSIDE BUILDING (EXACAVATION IN SEALED ENVIRONMENT. INCLUDING PAVEMENT AND CRAWL SPACE) | |||||||
| Scavo di fondazione eseguito all'interno dell'edificio (scavo in ambiente sigillato. Incluso demolizione pavimento e vespaio) | IT. No. Art. n. | 1a | CM/MC | 0.00 | 0.00 | |||
| 20 | DISPOSAL OF THE RESULT SOIL, INCLUDING TRANSPORT AND TAXES | |||||||
| Smaltimento del terreno di risulta, compreso trasporto e oneri | IT. No. Art. n. | 1b | CM/MC | 0.00 | 0.00 | |||
| 21 | DEMOLITION OF EXISTING STAIRS | |||||||
| Demolizione scale esistenti | IT. No. Art. n. | 2a | SM/MQ | 0.00 | 0.00 | |||
| 22 | REMOVAL AND DISPOSAL OF EXISTING METAL STRUCTURE | |||||||
| Rimozione e smaltimento struttura metallica esistente | IT. No. Art. n. | 2b | KG/KG | 0.00 | 0.00 | |||
| 23 | DEMOLITION OF FLOOR SLAB | |||||||
| Demolizione di solaio | IT. No. Art. n. | 2c | SM/MQ | 0.00 | 0.00 | |||
| Total Structural Demolition - Totale Demolizioni Strutturali | 0.00 | 0.00 | 0.00 | 0.00 |
| Id Mechanical Demolitions - Id Demolizioni Meccaniche | 0.00 | 0.00 | 0.00 | |||||||
| 24 | Demolition of part of the wall and/or of the pavement of the existing bathroom at ground floor to connect new drain and sanitary water system to existing systems. | |||||||||
| Demolizione di parte del muro e / o della pavimentazione del bagno esistente al piano terra per collegare il nuovo sistema di drenaggio e acqua sanitaria ai sistemi esistenti. | IT. No. Art. n. | 1 | EA/NO | 0.00 | 0.00 | 0.00 | 0.00 | |||
| 25 | Remove completely existing HVAC system with all related accessories, supports, dampers, grilles and registers. After the removal the site has to be cleaned and completely free for the new installation. | |||||||||
| Rimozione completa del sistema HVAC esistente con tutti i relativi accessori, supporti, serrande, griglie e canali. Dopo la rimozione il sito deve essere pulito e completamente libero per la nuova installazione. | IT. No. Art. n. | 2 | EA/NO | 0.00 | 0.00 | 0.00 | ||||
| Total Mechanical Demolitions - Totale Demolizioni Meccaniche | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||
| 0.00 | ||||||||||
| Ie Electrical Demolition - Ie Demolizioni Elettriche | 0.00 | |||||||||
| 26 | REMOVAL AND DISPOSAL OF THE EXISTING ELECTRICAL SYSTEM | |||||||||
| Rimozione dell'impianto elettrico esistente | IT. No. Art. n. | 1 | LS/AC | 0.00 | 0.00 | 0.00 | ||||
| Total Electrical Demolitions - Totale Demolizioni Elettriche | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TOTAL PART I / Totale Parte I 0.00 0.00 0.00 0.00
| PART II - ARCHITECTURAL, STRUCTURAL AND CIVIL WORK / Parte II - Lavori Architettonici, Strutturali e Civili | ||||||
| Iia Civil - IIa Civile | ||||||
| 27 | SAND FOR PIPE BEDDING | |||||
| Riempimento con sabbia per allettamento tubazioni | IT. No. Art. n. | 1a | CM/MC | 0.00 | 0.00 | 0.00 |
| 28 | CORRUGATED PIPE DIAM.125 | |||||
| Tubo corrugato diam.125 | IT. No. Art. n. | 1b | ML/LM | 0.00 | 0.00 | 0.00 |
| 29 | 40x40x40 PRECAST CONCRETE HANDHOLE INCLUDING COVER | |||||
| Pozzetto prefabbricato in calcestruzzo 40x40x40 icluso coperchio | IT. No. Art. n. | 1c | EA/NO | 0.00 | 0.00 | 0.00 |
| 30 | RESTORE PAVERS FLOORING | |||||
| Ripristino pavimentazione in betonelle | IT. No. Art. n. | 1d | SM/MQ | 0.00 | 0.00 | 0.00 |
| 31 | RESTORE CONCRETE CRUBS | |||||
| Ripristino cordonata prefabbricata in calcestruzzo | IT. No. Art. n. | 1e | LM/ML | 0.00 | 0.00 | 0.00 |
| 32 | LEAN CONCRETE TYPE C12/15 |
Getto in opera di calcestruzzo C12/15 non armato per magrone di
| fondazione | IT. No. Art. n. | 2a | CM/MC | 0.00 | 0.00 | 0.00 |
| 33 | REINFORCED CONCRETE FOR SLAB | |||||
| Platea in getto di calcestruzzo armato. Cassero a perdere | IT. No. Art. n. | 2b | CM/MC | 0.00 | 0.00 | 0.00 |
| 34 | REINFORCED CONCRETE SLAB DIAM.8/20x20 ELECTROWELDED NET | |||||
| Rete elettrosaldata diam.8/20x20 per armatura massetto | IT. No. Art. n. | 2c | KG/KG | 0.00 | 0.00 | 0.00 |
| 35 | STRECHED METAL SHEET H.230cm INCLUDING SUPPORT STRUCTURE | |||||
| Lamiera stirata h230Cm inclusa struttura di sostegno | IT. No. Art. n. | 2d | LM/ML | 0.00 | 0.00 | 0.00 |
| 36 | MIXED QUARRY MATERIAL FOR CONSTIPATION EQUAL TO 95%-100% OF THE AASHTO MAXIMUM DENSITY | |||||
| Ritombamenti in materiale misto di cava per costipamento pari al 95%-100% della densità massima AASHTO | IT. No. Art. n. | 3a | CM/MC | 0.00 | 0.00 | 0.00 |
| 37 | LEAN CONCRETE TYPE C12/15 |
Getto in opera di calcestruzzo C12/15 non armato per magrone di
| fondazione | IT. No. Art. n. | 3b | CM/MC | 0.00 | 0.00 | 0.00 | |||
| 38 | REINFORCED CONCRETE FOR SLAB | ||||||||
| Platea in getto di calcestruzzo armato. Cassero a perdere | IT. No. Art. n. | 3c | CM/MC | 0.00 | 0.00 | 0.00 | |||
| 39 | REINFORCED CONCRETE SLAB DIAM.8/20x20 ELECTROWELDED NET | ||||||||
| Rete elettrosaldata diam.8/20x20 per armatura massetto | IT. No. Art. n. | 3d | KG/KG | 0.00 | 0.00 | 0.00 | |||
| 40 | SUPPLY AND INSTALL PRECAST CONCRETE CURBS | ||||||||
| Fornitura e posa in opera di cordonata in calcestruzzo | IT. No. Art. n. | 3e | LM/ML | 0.00 | 0.00 | 0.00 | |||
| 41 | SUPPLY AND INSTALL DIAM.125mm PERFORATED CORRUGATED PIPE | ||||||||
| Fornitura e posa in opera di tubo corrugato microforato diam.125mm | IT. No. Art. n. | 4a | LM/ML | 0.00 | 0.00 | 0.00 | |||
| 42 | SUPPLY AND INSTALL DIAM.110mm PVC PIPE | ||||||||
| Fornitura e posa in opera di tubo in PVC diam.110mm | IT. No. Art. n. | 4b | LM/ML | 0.00 | 0.00 | 0.00 | |||
| 43 | SUPPLY AND INSTALL ROUND METAL VENTILATION GRILLES | ||||||||
| Fornitura e posa in opera di griglie di ventilazione in metallo rotonde | IT. No. Art. n. | 4c | EA/NO | 0.00 | 0.00 | 0.00 | |||
| 44 | GRASS SEEDING | ||||||||
| Semina | IT. No. Art. n. | 5 | SM/MQ | 0.00 | 0.00 | 0.00 | |||
| Total Civil - Totale Civili | 0.00 | 0.00 | 0.00 | 0.00 |
| IIb Architectural - IIb Architettonico | |||||||||
| 27 | CORE HOLES AND METAL SLIVES FOR TECHNICAL INSTALLATIONS PENETRATION | ||||||||
| Carotature su muratura e manicotti per passaggio impianti | IT. No. Art. n. | 1 | EA/NO | 0.00 | 0.00 | ||||
| 28 | WATERPROOFING MEMBRANE ON FOUNDATION | ||||||||
| Membrana impermeabilizzante sulle fondazioni | IT. No. Art. n. | 2a | SM/MQ | 0.00 | 0.00 | 0.00 | |||
| 29 | ANTI-RADON MEMBRANE | ||||||||
| Membrana anti radon sopra massetto armato | IT. No. Art. n. | 2b | SM/MQ | 0.00 | 0.00 | 0.00 | |||
| 30 | THK.5cm HIGH DENSITY EXTRUDED POLYSTYRENE FOR MEZZANINE FLOOR | ||||||||
| Polistirene estruso ad alta densità per pavimento mezzanino sp.5 cm | IT. No. Art. n. | 3a | SM/MQ | 0.00 | 0.00 | 0.00 | |||
| 31 | FLOOR SCREED - ISOCAL TYPE THICK.8cm | ||||||||
| Sottofondo per pavimenti tipo ISOCAL sp.8cm | IT. No. Art. n. | 3b | SM/MQ | 0.00 | 0.00 | 0.00 | |||
| 32 | FLOOR ACUSTICAL INSULATION - THICK.5mm | ||||||||
| isolamento acustico a pavimento - materassino sp.5mm | IT. No. Art. n. | 3c | SM/MQ | 0.00 | 0.00 | 0.00 | |||
| 33 | FLOOR SCREED thick.4cm | ||||||||
| Sottofondo per pavimenti, spessore 4cm | IT. No. Art. n. | 3d | SM/MQ | 0.00 | 0.00 | 0.00 | |||
| 34 | NON-SLIP FLOOR TILES 60x60CM | ||||||||
| Piastrelle antisdrucciolo 60x60cm | IT. No. Art. n. | 4a | SM/MQ | 0.00 | 0.00 | 0.00 | |||
| 35 | NON-SLIP FLOOR TILES 30x30CM (ENTRANCE FLOOR) | ||||||||
| Piastrelle antisdrucciolo 30x30cm (Pavimento ingresso) | IT. No. Art. n. | 4b | SM/MQ | 0.00 | 0.00 | 0.00 | |||
| 36 | NON-SLIP FLOOR TILES 20x20CM | ||||||||
| Piastrelle antisdrucciolo 20x20cm | IT. No. Art. n. | 4c | SM/MQ | 0.00 | 0.00 | 0.00 | |||
| 37 | BASEBOARD IN CERAMICS TILES | ||||||||
| Battiscopa interno in ceramica | IT. No. Art. n. | 4d | M/M | 0.00 | 0.00 | 0.00 | |||
| 38 | CONCRETE PAVING WITH QUARTZ HARDENER | ||||||||
| Pavimentazione in calcestruzzo con indurente quarzifero | IT. No. Art. n. | 5 | SM/MQ | 0.00 | 0.00 | 0.00 | |||
| 39 | 40x40cm RAISED FLOOR | ||||||||
| Pavimento flottante dim.40x40Cm | IT. No. Art. n. | 6 | SM/MQ | 0.00 | 0.00 | 0.00 | |||
| 40 | WALL LINING CERAMIC TILES | ||||||||
| Rivestimento in piastrelle | IT. No. Art. n. | 7 | SM/MQ | 0.00 | 0.00 | 0.00 | |||
| 41 | SUPPLY AND APPLY FLOOR CARPET | ||||||||
| Fornitura e posa in opera di moquette | IT. No. Art. n. | 8 | SM/MQ | 0.00 | 0.00 | 0.00 | |||
| 41 | SOUNDPROOF DOUBLE LAYER GYPSUM BOARD PARTITIONS - W4 type (12,5+75mm+12,5mm) | ||||||||
| Costruzione di pareti in cartongesso fonoisolanti con doppie lastra - Tipo W4 (12,5mm+75mm+12,5mm) | IT. No. Art. n. | 9a | SM/MQ | 0.00 | 0.00 | 0.00 | |||
| 42 | SOUNDPROOF DOUBLE LAYER GYPSUM BOARD PARTITIONS - W5 type (12,5+50mm+12,5mm) | ||||||||
| Costruzione di pareti in cartongesso fonoisolanti con doppie lastra - Tipo W5 (12,5mm+50mm+12,5mm) | IT. No. Art. n. | 9b | SM/MQ | 0.00 | 0.00 | 0.00 | |||
| 43 | SOUNDPROOF DOUBLE LAYER GYPSUM BOARD PARTITIONS - W6-W7 type (12,5+100mm+12,5mm) | ||||||||
| Costruzione di pareti in cartongesso fonoisolanti con doppie lastra - Tipo W6-W7 (12,5mm+100mm+12,5mm) | IT. No. Art. n. | 9c | SM/MQ | 0.00 | 0.00 | 0.00 | |||
| 44 | MOISTURE RESISTANT GYPSUM BOARD | ||||||||
| Sovrapprezzo per utilizzo di lastre idrorepellenti | IT. No. Art. n. | 9d | SM/MQ | 0.00 | 0.00 | ||||
| 45 | "KNAUF SILENTBOARD" GYPSUM BOARD | ||||||||
| Sovrapprezzo per utilizzo di lastre tipo "Knauf Silentboard" | IT. No. Art. n. | 9e | SM/MQ | 0.00 | 0.00 | ||||
| 46 | 40mm ROCWOOL ACOUSTICAL INSULATING BATT 40Kg/cm | ||||||||
| Materassino fonoisolante in lana di roccia sp.40mm 40kg/mc | IT. No. Art. n. | 9f | SM/MQ | 0.00 | 0.00 | ||||
| 47 | 60mm ROCWOOL ACOUSTICAL INSULATING BATT 40Kg/cm | ||||||||
| Materassino fonoisolante in lana di roccia sp.60mm 40kg/mc | IT. No. Art. n. | 9g | SM/MQ | 0.00 | 0.00 | ||||
| 48 | 80mm MINERAL WOOL ACOUSTICAL INSULATING BATT 17Kg/cm | ||||||||
| Materassino fonoisolante in lana minerale sp.80mm 17kg/mc | IT. No. Art. n. | 9h | SM/MQ | 0.00 | 0.00 | ||||
| 49 | SOUNDPROOF DOUBLE LAYER GYPSUM BOARD COUNTERWALL (75mm+12,5mm+12,5mm) | ||||||||
| Costruzione di contropareti in cartongesso fonoisolanti con doppie lastra - (75mm++12,5mm+12,5mm) | IT. No. Art. n. | 10a | SM/MQ | 0.00 | 0.00 | 0.00 | |||
| 50 | MOISTURE RESISTANT GYPSUM BOARD | ||||||||
| Sovrapprezzo per utilizzo di lastre idrorepellenti | IT. No. Art. n. | 10b | SM/MQ | 0.00 | 0.00 | ||||
| 51 | "KNAUF SILENTBOARD" GYPSUM BOARD | ||||||||
| Sovrapprezzo per utilizzo di lastre tipo "Knauf Silentboard" | IT. No. Art. n. | 10c | SM/MQ | 0.00 | 0.00 | ||||
| 52 | 50mm ROCWOOL ACOUSTICAL INSULATING BATT 80Kg/cm | ||||||||
| Materassino fonoisolante in lana di roccia sp.50mm 80kg/mc | IT. No. Art. n. | 10d | SM/MQ | 0.00 | 0.00 | ||||
| 53 | 2x50mm POLYSTYRENE PANELS FIXED ON EXISTING WALL | ||||||||
| 2x50mm pannello in polistirene fissato alla muratura esistente | IT. No. Art. n. | 10e | SM/MQ | 0.00 | 0.00 | 0.00 | |||
| 54 | 10mm PUR-ETHER FOAM SOUND ABSORBER PANELS | ||||||||
| Pannelli fonoassorbenti sp.10mm in schiuma "pur-ether" | IT. No. Art. n. | 11 | SM/MQ | 0.00 | 0.00 | 0.00 | |||
| 55 | MINERAL FIBER SUSPENDED CEILING (600X600mm) | ||||||||
| Controsoffitto in lana minerale (600X600mm) | IT. No. Art. n. | 12a | SM/MQ | 0.00 | 0.00 | 0.00 | |||
| 56 | MINERAL FIBER SUSPENDED CEILING -WATER REPELLENT (600X600mm) | ||||||||
| Controsoffitto in fibra minerale idrorepellente (600X600mm) | IT. No. Art. n. | 12b | SM/MQ | 0.00 | 0.00 | 0.00 | |||
| 57 | CONSTRUCTION OF GYPSUM VEIL | ||||||||
| Formazione di velette verticali in cartongesso | IT. No. Art. n. | 12c | LM/ML | 0.00 | 0.00 | 0.00 | |||
| 58 | NEW CONTINUE SINGLE GYPSUMBOARD FALSE CEILING | ||||||||
| Controsoffitto continuo in cartongesso a lastra singola | IT. No. Art. n. | 13 | SM/MQ | 0.00 | 0.00 | 0.00 | |||
| 59 | WALL PAINTING | ||||||||
| Verniciatura pareti | IT. No. Art. n. | 14a | SM/MQ | 0.00 | 0.00 | 0.00 | |||
| 60 | INTUMESCENT PAINTING OF STEEL STRUCTURES | ||||||||
| Verniciatura intumescente strutture in acciaio a vista | IT. No. Art. n. | 14b | SM/MQ | 0.00 | 0.00 | 0.00 | |||
| 61 | SILLS FOR EXTERNAL DOORS IN NATURAL STONE "PIASENTINA" | ||||||||
| Soglie per porte esterne In pietra piasentina | IT. No. Art. n. | 15a | SM/MQ | 0.00 | 0.00 | 0.00 | |||
| 62 | EXTERNAL WINDOWSILLS IN NATURAL STONE "PIASENTINA" | ||||||||
| Davanzali per finestre esterne In pietra piasentina | IT. No. Art. n. | 15b | SM/MQ | 0.00 | 0.00 | 0.00 | |||
| 63 | EXTERNAL ALUMINUM WINDOWS | ||||||||
| Serramenti in alluminio | IT. No. Art. n. | 16a | SM/MQ | 0.00 | 0.00 | 0.00 | |||
| 64 | INTERNAL CURTAINS (VENETIAN BLIND/ROLLER BLIND) - FOR WINDOWS | ||||||||
| Tende interne alla veneziana/tende oscuranti - per finestre | IT. No. Art. n. | 16b | SM/MQ | 0.00 | 0.00 | 0.00 | |||
| 65 | ROLL-UP INSECT SCREEN FOR WINDOWS | ||||||||
| Zanzariere avvolgibili per finestre | IT. No. Art. n. | 16c | SM/MQ | 0.00 | 0.00 | 0.00 | |||
| 66 | PERIMETER PROFILE OF SUPPORT FRAMES (external windows) | ||||||||
| Controtelaio su serramenti (finestre esterne) | IT. No. Art. n. | 16d | M/M | 0.00 | 0.00 | 0.00 | |||
| 67 | EXTERNAL ALUMINUM DOORS | ||||||||
| Serramenti (porte) in alluminio | IT. No. Art. n. | 17a | SM/MQ | 0.00 | 0.00 | 0.00 | |||
| 68 | PERIMETER PROFILE OF SUPPORT FRAMES (porte windows) | ||||||||
| Controtelaio su serramenti (porte esterne) | IT. No. Art. n. | 17b | M/M | 0.00 | 0.00 | 0.00 | |||
| 69 | PANIC EXIT DEVICE (door with one opening) | ||||||||
| Maniglione antipanico (porta ad una anta) | IT. No. Art. n. | 17c | EA/NO | 0.00 | 0.00 | 0.00 | |||
| 70 | PANIC EXIT DEVICE (door with two openings) | ||||||||
| Maniglione antipanico (porta a due ante) | IT. No. Art. n. | 17d | EA/NO | 0.00 | 0.00 | 0.00 | |||
| 71 | INTERNAL DOORS WITH ALUMINUM FRAME (hollow panel covered with plastic laminate) | ||||||||
| Porte interne ad un battente cieche con telaio in alluminio (pannello tamburato rivestito in laminato plastico) | IT. No. Art. n. | 18a | SM/MQ | 0.00 | 0.00 | 0.00 | |||
| 72 | INTERNAL ACOUSTICAL DOORS | ||||||||
| Porte interne acustiche | IT. No. Art. n. | 18b | SM/MQ | 0.00 | 0.00 | 0.00 | |||
| 73 | SUPPLY AND INSTALL DOOR LOUVERS DIM.300x200mm | ||||||||
| Fornitura e posa di Griglia di areazione su porta dim. 300x200mm | IT. No. Art. n. | 18c | SM/MQ | 0.00 | 0.00 | 0.00 | |||
| 74 | PLASTIC LAMINATE TOLIET PARTITION, H 210cm | ||||||||
| Divisori bagni in laminato plastico, h 210cm | IT. No. Art. n. | 19 | SM/MQ | 0.00 | 0.00 | 0.00 | |||
| 74 | TOILET FIXTURES | ||||||||
| Apparecchi sanitari | IT. No. Art. n. | 20 | LS/AC | 0.00 | 0.00 | 0.00 | |||
| 75 | VAPOR BARRIER ON COVERAGE | ||||||||
| Barriera vapore per copertura | IT. No. Art. n. | 21a | SM/MQ | 0.00 | 0.00 | 0.00 | |||
| 76 | DOUBLE WALKABLE WHITE MEMBRANE "DERBIGUM" TYPE (INCLUDING COAT OF PRIMER VERPRIM PROFESSIONAL TYPE) AND 12 CM POLYURETHANE FOAM INSULATION | ||||||||
| Doppia guaina ardesiata colore bianco tipo "derbigum",(compresa stesa di primer fissativo tipo verprim professional) e isolamento da 12cm in poliuretano espanso | IT. No. Art. n. | 21b | SM/MQ | 0.00 | 0.00 | 0.00 | |||
| 77 | DOWNSPOUTS | ||||||||
| Pluviali | IT. No. Art. n. | 22a | M/M | 0.00 | 0.00 | 0.00 | |||
| 78 | REINFORCEMENT FOR DOWNSPOUTS | ||||||||
| Terminali pluviali in ghisa | IT. No. Art. n. | 22b | EA/NO | 0.00 | 0.00 | 0.00 | |||
| 79 | GUTTERS AND FLASHING | ||||||||
| Grondaie e scossaline | IT. No. Art. n. | 22c | M/M | 0.00 | 0.00 | 0.00 | |||
| 80 | ROOF SAFETY SYSTEM INCLUDED DESIGN, CALCULATION AND CERTIFICATION | ||||||||
| Sistema di sicurezza in copertura, compreso progetto, calcolo e certificazione | IT. No. Art. n. | 23a | AC/LS | 0.00 | 0.00 | 0.00 | |||
| 81 | SECURITY LADDER FOR ROOF ACCESS | ||||||||
| Scala di sicurezza per accesso alla copertura | IT. No. Art. n. | 23b | LS/AC | 0.00 | 0.00 | 0.00 | |||
| 74 | ELECTRIC HOIST | ||||||||
| Paranco elettrico | IT. No. Art. n. | 23c | LS/AC | 0.00 | 0.00 | 0.00 | |||
| Total Architectural - Totale Architettura | 0.00 | 0.00 | 0.00 | 0.00 |
| IIc Structural - IIc Strutturale | |
| 75 | LEAN CONCRETE TYPE C12/15 |
Getto in opera di calcestruzzo C12/15 non armato per magrone di
| fondazione | IT. No. Art. n. | 1a | CM/MC | 0.00 | 0.00 | 0.00 | |||
| 76 | REINFORCED CONCRETE FOUNDATIONS. C30/37 XC3 S4 | ||||||||
| Fondazioni dirette in getto di calcestruzzo armato C30/37 XC3 S4. Cassero a perdere | IT. No. Art. n. | 1b | CM/MC | 0.00 | 0.00 | 0.00 | |||
| 77 | REINFORCED CONCRETE STEEL BARS. B450C | ||||||||
| Barre in acciaio per cementi armati. B450C | IT. No. Art. n. | 1c | KG/KG | 0.00 | 0.00 | 0.00 | |||
| 78 | REINFORCED CONCRETE SLAB ON GRADE THICK.15 cm | ||||||||
| Massetto in calcestruzzo armato sp.15 cm | IT. No. Art. n. | 1d | CM/MC | 0.00 | 0.00 | 0.00 | |||
| 79 | REINFORCED CONCRETE SLAB DIAM.8/20x20 ELECTROWELDED NET | ||||||||
| Rete elettrosaldata diam.8/20x20 per armatura massetto | IT. No. Art. n. | 1e | KG/KG | 0.00 | 0.00 | 0.00 | |||
| 79 | SUPPLY, ASSEMBLY AND PROCESSING CARPENTRY - NEW MEZZANINE STRUCTURE, INCLUDING STAIR AND HANDRAIL | ||||||||
| Fornitura. montaggio e lavorazione di carpenteria metallica - nuova struttura mezzanino, inclusa scala e parapetti | IT. No. Art. n. | 2a | KG/KG | 0.00 | 0.00 | 0.00 | |||
| 80 | ANCHORING NEW METAL STRUCTURE AT THE CONCERETE FOUNDATIONS | ||||||||
| Ancoraggi di nuove strutture metalliche a fondazione in C.A., inclusa resina | IT. No. Art. n. | 2b | EA/NO | 0.00 | 0.00 | 0.00 | |||
| 81 | SLAB HI-BOND TYPE A55/P600 THICK 10/10mm h 10cm - FLOOR SLAB 4.5cm | ||||||||
| Solaio HI-BOND tipo A55/P600 s 10/10mm h 10cm - soletta armata s.4,5cm | IT. No. Art. n. | 3a | SM/MQ | 0.00 | 0.00 | 0.00 | |||
| 82 | SLAB HI-BOND REINFORCING DIAM.8/15x15 ELECTROWELDED NET | ||||||||
| Rete elettrosaldata diam.8/15x15 per armatura solaio HI-BOND | IT. No. Art. n. | 3b | KG/KG | 0.00 | 0.00 | 0.00 | |||
| 83 | STRUCTURAL GLASS PARAPET | ||||||||
| Parapetto in vetro strutturale | IT. No. Art. n. | 4 | SM/MQ | 0.00 | 0.00 | 0.00 | |||
| Total Structural - Totale Strutturale | 0.00 | 0.00 | 0.00 | 0.00 |
TOTAL PART II / Totale Parte II 0.00 0.00 0.00 0.00
| PART III - MECHANICAL WORK / Parte III - Lavori Meccanici | ||||||||||
| IIIa HVAC - IIIa HVAC | ||||||||||
| 84 | Supply and installation of pre-insulated aluminium HVAC ductwork | |||||||||
| Fornitura e installazione di condotte HVAC preisolate rivestite in alluminio | IT. No. Art. n. | 1 | SM/MQ | 0.00 | 0.00 | 0.00 | ||||
| 85 | Supply and installation of flexible ductwork Ø150. | |||||||||
| Fornitura ed installazione di canalizzazioni flessibili Ø150. | IT. No. Art. n. | 2.a | LM/M | 0.00 | 0.00 | 0.00 | ||||
| 86 | Supply and installation of flexible ductwork Ø200. | |||||||||
| Fornitura ed installazione di canalizzazioni flessibili Ø200. | IT. No. Art. n. | 2.b | LM/M | 0.00 | 0.00 | 0.00 | ||||
| 87 | Supply and installation of supply air diffusers, type Brofer BQE-1 Q-R 400 or similar | |||||||||
| Fornitura e installazione di diffusori di mandata dell'aria, tipo Brofer BQE-1 Q-R 400 o similari | IT. No. Art. n. | 3.a | EA/NO | 0.00 | 0.00 | 0.00 | 0.00 | |||
| 88 | Supply and installation of supply air diffusers, type Brofer BQE-1 Q-R 500 or similar | |||||||||
| Fornitura e installazione di diffusori di mandata dell'aria, tipo Brofer BQE-1 Q-R 500 o similari | IT. No. Art. n. | 3.b | EA/NO | 0.00 | 0.00 | 0.00 | 0.00 | |||
| 89 | Supply and installation of return air diffusers, type Brofer BQE-1 Q-R 400 or similar | |||||||||
| Fornitura e installazione di diffusori di ripresa dell'aria, tipo Brofer BQE-1 Q-R 400 o similari | IT. No. Art. n. | 4.a | EA/NO | 0.00 | 0.00 | 0.00 | 0.00 | |||
| 90 | Supply and installation of return air diffusers, type Brofer BQE-1 Q-R 500 or similar | |||||||||
| Fornitura e installazione di diffusori di ripresa dell'aria, tipo Brofer BQE-1 Q-R 500 o similari | IT. No. Art. n. | 4.b | EA/NO | 0.00 | 0.00 | 0.00 | 0.00 | |||
| 91 | Supply and installation of exhaust valve, type Brofer EAV-CR or similar | |||||||||
| Fornitura e installazione di valvola di estrazione, tipo Brofer EAV-CR o similare | IT. No. Art. n. | 5 | EA/NO | 0.00 | 0.00 | 0.00 | 0.00 | |||
| 92 | Supply and installation of air transfer grille, type Brofer GTA or similar | |||||||||
| Fornitura e installazione di griglia di transito, tipo Brofer GTA o similari | IT. No. Art. n. | 6 | EA/NO | 0.00 | 0.00 | 0.00 | 0.00 | |||
| 93 | Supply and installation of inlet and exhaust louvers, type Brofer GRI50-Z 600X400 or similar. | |||||||||
| Fornitura e installazione di louver di presa aria ed espulsione, tipo Brofer GRI50-Z 600X400 o similari | IT. No. Art. n. | 7 | EA/NO | 0.00 | 0.00 | 0.00 | 0.00 | |||
| 94 | Supply and installation of new condensing unit for Variable Refrigerant Volume system, brand DAIKIN model RXYSQ8TY1 or similar, "Intelligent Touch Manager" able to work on Bacnet protocol with remote supervision, first start, bms engineering. | |||||||||
| Fornitura e installazione di una nuova unità di condensazione per il sistema di volume del refrigerante variabile, marca DAIKIN modello RXYSQ8TY1 o simile, completa di "Intelligent Touch Manager" integrato con protocollo Bacnet per supervisione remota, primo avvio, ingegneria bms. | IT. No. Art. n. | 8 | EA/NO | 0.00 | 0.00 | 0.00 | ||||
| 95 | Supply and installation of new BACNET GATEWAY INTERFACE. | |||||||||
| Fornitura e installazione di una nuova INTERFACCIA BACNET. | IT. No. Art. n. | 9 | EA/NO | 0.00 | 0.00 | 0.00 | ||||
| 96 | Supply and installation of indoor units for ceiling installation for VRV system at R410A, brand DAIKIN model FXZQ-50A or similar | |||||||||
| Fornitura e installazione di unità interne per installazione a soffitto per sistema VRV a R410A, marca DAIKIN modello FXZQ-50A o simile | IT. No. Art. n. | 10.a | EA/NO | 0.00 | 0.00 | 0.00 | ||||
| 97 | Supply and installation of indoor units for ceiling installation for VRV system at R410A, brand DAIKIN model FXZQ-25A or similar | |||||||||
| Fornitura e installazione di unità interne per installazione a soffitto per sistema VRV a R410A, marca DAIKIN modello FXZQ-25A o simile | IT. No. Art. n. | 10.b | EA/NO | 0.00 | 0.00 | 0.00 | ||||
| 98 | Supply and installation of indoor units for floor standing installation for VRV system at R410A, brand DAIKIN model FXLQ32P or similar | |||||||||
| Fornitura e installazione di unità interne per installazione a pavimento per sistema VRV su R410A, marca DAIKIN modello FXLQ32P o simile | IT. No. Art. n. | 10.c | EA/NO | 0.00 | 0.00 | 0.00 | ||||
| 98 | Supply and installation of indoor units for floor standing installation for VRV system at R410A, brand DAIKIN model FXLQ20P or similar | |||||||||
| Fornitura e installazione di unità interne per installazione a pavimento per sistema VRV su R410A, marca DAIKIN modello FXLQ20P o simile | IT. No. Art. n. | 10.d | EA/NO | 0.00 | 0.00 | 0.00 | ||||
| 99 | Supply and installation of monosplit for server room, R32, brand DAIKIN model FTXM50R+RXM50R or similar. | |||||||||
| Fornitura e installazione di monosplit dedicato al locale server, R32, brand DAIKIN model FTXM50R+RXM50R o simile | IT. No. Art. n. | 11 | EA/NO | 0.00 | 0.00 | 0.00 | ||||
| 100 | Supply and installation of Heat Recovery Ventilation unit for VRV system at R410A, brand DAIKIN model VKM100GMB or similar | |||||||||
| Fornitura e installazione di unità di ventilazione con recupero di calore per sistema VRV a R410A, marca DAIKIN modello VKM100GMB o simile | IT. No. Art. n. | 12 | EA/NO | 0.00 | 0.00 | 0.00 | ||||
| 101 | Supply of all ductwork system testing and balancing with new design air flow rate as per mechanical drawings and specification | |||||||||
| Fornitura del servizio completo di test e bilanciamento degli impianti HVCA in accordo con il progetto degli impianti meccanici e specifiche | IT. No. Art. n. | 13 | EA/NO | 0.00 | 0.00 | |||||
| 102 | Supply and installation of electric radiator 500 W | |||||||||
| Fornitura e posa in opera di radiatore elettrico da 500 W | IT. No. Art. n. | 14 | EA/NO | 0.00 | 0.00 | 0.00 | ||||
| Total HVAC - Totale HVAC | 0.00 | 0.00 | 0.00 | 0.00 |
| IIIb Plumbing - IIIb Idrico sanitario | |||||||||
| 103 | Supply and installation of all new condensate drain pipes system for all new DX units and all sewage and vent pipes for new wash basins and w.c. in toilet area. | ||||||||
| Fornitura e installazione del sistema di drenaggio condensa per le nuove unità DX e di scarico e ventilazione per i bagni. | IT. No. Art. n. | 15 | EA/NO | 0.00 | 0.00 | 0.00 | |||
| 104 | Supply and installation of all new sanitary cold and hot water pipes system serving all the floors, the DOAS units (heat recovery DX units) and bathrooms. | ||||||||
| Fornitura e installazione di tubazioni per acqua calda e fredda a servizio di tutti i piani, unità DOAS (unità DX a recupero di calore) e bagni. | IT. No. Art. n. | 16 | EA/NO | 0.00 | 0.00 | 0.00 | |||
| 105 | Supply and installation of a wall-mounted washbasin, complete with sewage and water pipes, and battery electronic basin mixer group with infrared sensor . | ||||||||
| Fornitura e installazione di lavabo a parete completo di tubazioni di scarico ed adduzione idrica, e miscelatore elettronico ad infrarossi a batteria. | IT. No. Art. n. | 17 | EA/NO | 0.00 | 0.00 | 0.00 | |||
| 106 | Supply and installation of a floor mounted w.c., complete with sewage and water pipes, flushing cassette. | ||||||||
| Fornitura e installazione di w.c. a pavimento completo di tubazioni di scarico ed adduzione idrica, e cassetta di risciaquo. | IT. No. Art. n. | 18 | EA/NO | 0.00 | 0.00 | 0.00 | |||
| 107 | Supply and installation of a floor mounted shower plate, complete with sewage and water pipes, mixer group. | ||||||||
| Fornitura e installazione di piatto doccia a pavimento, completo di tubazioni di scarico ed adduzione idrica, e miscelatore. | IT. No. Art. n. | 19 | EA/NO | 0.00 | 0.00 | 0.00 | |||
| 108 | Supply and installation of a 60 liters electric water heater. | ||||||||
| Fornitura e installazione di scaldabagno elettrico da 60 litri. | IT. No. Art. n. | 20 | EA/NO | 0.00 | 0.00 | 0.00 | |||
| Total Plumbing - Totale Idrico sanitario | 0.00 | 0.00 | 0.00 | 0.00 |
TOTAL PART III / Totale Parte III 0.00 0.00 0.00 0.00
| PART IV - ELECTRICAL WORK / Parte IV - Lavori Elettrici | |||||||||
| 109 | ELECTRICAL PANELS AND TRASFORMER | ||||||||
| Nuovi quadri elettrici e trasformatore | IT. No. Art. n. | 1 | EA | 0.00 | 0.00 | 0.00 | |||
| 110 | EXISTING UPS MOVING | ||||||||
| Spostamento UPS esistente | IT. No. Art. n. | 2 | LS/AC | 0.00 | 0.00 | 0.00 | |||
| 111 | METAL CABLE TRAYS AND BASKET TYPE CABLE TRAYS, JUNCTION BOXES | ||||||||
| Canali, scatole | IT. No. Art. n. | 8-9 | LM | 0.00 | 0.00 | 0.00 | |||
| 112 | FO CABLES | ||||||||
| Cavi in fibra ottica | IT. No. Art. n. | 5 | LM | 0.00 | 0.00 | 0.00 | |||
| 113 | LV CABLES AND WIRING | ||||||||
| Cavi di bassa tensione e collegamenti | IT. No. Art. n. | 3 | LM | 0.00 | 0.00 | 0.00 | |||
| 114 | COMM CABLES | ||||||||
| Cavi dati | IT. No. Art. n. | 6 | LM | 0.00 | 0.00 | 0.00 | |||
| 115 | FIRE ALARM CABLES | ||||||||
| Cavo loop antincendio | IT. No. Art. n. | 4 | LM | 0.00 | 0.00 | 0.00 | |||
| 116 | DALI LIGHTING CABLES | ||||||||
| Cavo BUS DALI | IT. No. Art. n. | 7 | LM | 0.00 | 0.00 | 0.00 | |||
| 117 | GALVANIZED STEEL PIPES, JUNCTION BOXES | ||||||||
| Tubi in acciaio zincato, scatole | IT. No. Art. n. | 10 | LM | 0.00 | 0.00 | 0.00 | |||
| 118 | PVC PIPES, JUCTION BOXES | ||||||||
| Tubi in PVC rigidi/flessibili/doppia parete, scatole | IT. No. Art. n. | 11-13 | LM | 0.00 | 0.00 | 0.00 | |||
| 119 | CONCRETE MANHOLES AND COVERS | ||||||||
| Pozzetti in cls e coperchi | IT. No. Art. n. | 14 | EA/NO | 0.00 | 0.00 | 0.00 | |||
| 120 | EMERGENCY GENERATOR AND TANK | ||||||||
| Gruppo Elettrogeno e serbatoio Diesel | IT. No. Art. n. | 15 | LS/AC | 0.00 | 0.00 | 0.00 | |||
| 120 | MANSORY AND CONSTRUCTION WORK ASSISTANCE | ||||||||
| Assistenze edili | IT. No. Art. n. | 16 | LS/AC | 0.00 | 0.00 | 0.00 | |||
| 121 | FIRESTOPPING | ||||||||
| Ripristino resistenza al fuoco strutture | IT. No. Art. n. | 17 | LS/AC | 0.00 | 0.00 | 0.00 | |||
| 122 | RECESSED FLOOR BOXES | ||||||||
| Torrette incassate | IT. No. Art. n. | 18 | EA/NO | 0.00 | 0.00 | 0.00 | |||
| 123 | POWER SYSTEM, POWER RECEPTACLES, ETC. | ||||||||
| Forza motrice, prese, ecc. | IT. No. Art. n. | 19 | EA/NO | 0.00 | 0.00 | 0.00 | |||
| 124 | PUSH BUTTON 230V, 10A FOR LIGHTING FIXTURE | ||||||||
| pulsante di comando illuminazione | IT. No. Art. n. | 20 | EA/NO | 0.00 | 0.00 | 0.00 | |||
| 125 | PASSIVE INFRARED DETECTOR | ||||||||
| rivelatore ad infrarossi passivi (sensore di presenza) | IT. No. Art. n. | 21 | EA/NO | 0.00 | 0.00 | 0.00 | |||
| 126 | DUSKY SENSOR | ||||||||
| sensore crepuscolare | IT. No. Art. n. | 22 | EA/NO | 0.00 | 0.00 | 0.00 | |||
| 127 | NEW UPS | ||||||||
| Nuovo UPS | IT. No. Art. n. | 23 | EA/NO | 0.00 | 0.00 | 0.00 | |||
| 128 | ORDINARY LIGHTING FIXTURE TYPE 2 AND 3 (AS SHOWN ON DRAWINGS) | ||||||||
| lampada d'illuminazione ordinaria tipo 2 e 3 (come da tavole grafiche) | IT. No. Art. n. | 24 | EA/NO | 0.00 | 0.00 | 0.00 | |||
| 129 | ORDINARY LIGHTING FIXTURE TYPE 4 (AS SHOWN ON DRAWINGS) | ||||||||
| lampada d'illuminazione ordinaria tipo 4 (come da tavole grafiche) | IT. No. Art. n. | 25 | EA/NO | 0.00 | 0.00 | 0.00 | |||
| 130 | ORDINARY LIGHTING FIXTURE TYPE 5 (AS SHOWN ON DRAWINGS) | ||||||||
| lampada d'illuminazione ordinaria tipo 5 (come da tavole grafiche) | IT. No. Art. n. | 25 | EA/NO | 0.00 | 0.00 | 0.00 | |||
| 131 | ORDINARY LIGHTING FIXTURE TYPE 13 (AS SHOWN ON DRAWINGS) | ||||||||
| lampada d'illuminazione ordinaria tipo 13 (come da tavole grafiche) | IT. No. Art. n. | 26 | EA/NO | 0.00 | 0.00 | 0.00 | |||
| 132 | ORDINARY LIGHTING FIXTURE TYPE 14 (AS SHOWN ON DRAWINGS) | ||||||||
| lampada d'illuminazione ordinaria tipo 14 (come da tavole grafiche) | IT. No. Art. n. | 26 | EA/NO | 0.00 | 0.00 | 0.00 | |||
| 133 | ORDINARY LIGHTING FIXTURE TYPE 18 (AS SHOWN ON DRAWINGS) | ||||||||
| lampada d'illuminazione ordinaria tipo 18 (come da tavole grafiche) | IT. No. Art. n. | 26 | EA/NO | 0.00 | 0.00 | 0.00 | |||
| 134 | ORDINARY LIGHTING FIXTURE TYPE 8 (AS SHOWN ON DRAWINGS) | ||||||||
| lampada d'illuminazione ordinaria tipo 8 (come da tavole grafiche) | IT. No. Art. n. | 27 | EA/NO | 0.00 | 0.00 | 0.00 | |||
| 135 | EMERGENCY LIGHTING FIXTURE TYPE 1/EL (AS SHOWN ON DRAWINGS) | ||||||||
| illuminazione emergenza tipo 1/EL (come da tavole grafiche) | IT. No. Art. n. | 28 | EA/NO | 0.00 | 0.00 | 0.00 | |||
| 136 | EMERGENCY LIGHTING FIXTURE TYPE 6/EL, 7/EL AND 8/EL (AS SHOWN ON DRAWINGS) | ||||||||
| illuminazione emergenza tipo 6/EL, 7/EL AND 8/EL (come da tavole grafiche) | IT. No. Art. n. | 29 | EA/NO | 0.00 | 0.00 | 0.00 | |||
| 137 | EMERGENCY LIGHTING FIXTURE TYPE 9/EL AND 10/EL (AS SHOWN ON DRAWINGS) | ||||||||
| illuminazione emergenza tipo 9/EL and 10/EL (come da tavole grafiche) | IT. No. Art. n. | 30 | EA/NO | 0.00 | 0.00 | 0.00 | |||
| 138 | EMERGENCY LIGHTING FIXTURE TYPE 12/EL (AS SHOWN ON DRAWINGS) | ||||||||
| illuminazione emergenza tipo 12/EL (come da tavole grafiche) | IT. No. Art. n. | 31 | EA/NO | 0.00 | 0.00 | 0.00 | |||
| 139 | EMERGENCY LIGHTING FIXTURE TYPE 11/EL (AS SHOWN ON DRAWINGS) | ||||||||
| illuminazione emergenza tipo 11/EL (come da tavole grafiche) | IT. No. Art. n. | 31 | EA/NO | 0.00 | 0.00 | 0.00 | |||
| 140 | EMERGENCY LIGHTING FIXTURE TYPE 16/EL AND 17/EL (AS SHOWN ON DRAWINGS) | ||||||||
| illuminazione emergenza tipo 16/EL and 17/EL (come da tavole grafiche) | IT. No. Art. n. | 32 | EA/NO | 0.00 | 0.00 | 0.00 | |||
| 141 | DALI SOFTWARE, TOUCHSCREEN, ENGINEERING, PROGRAMMING AND START-UP | ||||||||
| Software DALI, touchscreen, attività di engineering, programmazione e start-up | IT. No. Art. n. | 33 | LS/AC | 0.00 | 0.00 | 0.00 | |||
| 142 | DATA COMM OUTLETS | ||||||||
| Prese dati a muro | IT. No. Art. n. | 34 | EA/NO | 0.00 | 0.00 | 0.00 | |||
| 143 | DATA RACK WITH ACCESSORIES AND BACKUP DATA RACK | ||||||||
| Rack dati con accessori e rack dati di backup | IT. No. Art. n. | 35 | LS/AC | 0.00 | 0.00 | 0.00 | |||
| 144 | DESKTOP VOIP PHONE | ||||||||
| telefono VOIP da scrivania | IT. No. Art. n. | 36 | EA/NO | 0.00 | 0.00 | 0.00 | |||
| 145 | POWER SUPPLY | ||||||||
| Alimentatore per strobe | IT. No. Art. n. | 37a | EA/NO | 0.00 | 0.00 | 0.00 | |||
| 146 | STROBE | ||||||||
| segnalatore ottico | IT. No. Art. n. | 37b | EA/NO | 0.00 | 0.00 | 0.00 | |||
| 147 | ALARM PUSH STATION | ||||||||
| pulsante manuale d'allarme | IT. No. Art. n. | 37c | EA/NO | 0.00 | 0.00 | 0.00 | |||
| 148 | OPTICAL SMOKE DETECTOR | ||||||||
| rivelatori ottici di fumo | IT. No. Art. n. | 37d | EA/NO | 0.00 | 0.00 | 0.00 | |||
| 149 | OPTICAL REPEATER | ||||||||
| ripetitore ottico di allarme per rivelatori dentro i controsoffitti | IT. No. Art. n. | 37e | EA/NO | 0.00 | 0.00 | 0.00 | |||
| 150 | EMERGENCY AIR SHUTOFF BUTTON | ||||||||
| pulsanti manuali per l'interruzione della ventilazione meccanica | IT. No. Art. n. | 37f | EA/NO | 0.00 | 0.00 | 0.00 | |||
| 151 | OPTICAL ACOUSTIC PANEL | ||||||||
| pannello ottico acustico | IT. No. Art. n. | 37g | EA/NO | 0.00 | 0.00 | 0.00 | |||
| 152 | START-UP AND NEW CONFIGURATION | ||||||||
| start-up and new configuration | IT. No. Art. n. | 37h | LS/AC | 0.00 | 0.00 | 0.00 | |||
| 153 | VIDEO INTERCOM | ||||||||
| Impianto di intercomunicazione, citofono | IT. No. Art. n. | 38 | LS/AC | 0.00 | 0.00 | 0.00 | |||
| Total electrical - Totale Elettrico | 0.00 | 0.00 | 0.00 | 0.00 |
TOTAL PART IV / Totale Parte IV 0.00 0.00 0.00 0.00
| REPAIR WORKS SUMMARY / Riepilogo Lavori di Ristrutturazione | ||||||
| PART I - DEMOLITIONS AND REMOVALS | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| PART II - ARCHITECTURAL, STRUCTURAL AND CIVIL WORKS | 0.00 | 0.00 | 0.00 | 0.00 | ||
| PART III - MECHANICAL WORKS | 0.00 | 0.00 | 0.00 | 0.00 | ||
| PART IV - ELECTRICAL WORK | 0.00 | 0.00 | 0.00 | 0.00 | ||
| TOTAL PRICE / Costo Totale | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Summary / Riepilogo Complessivo | |||||
| A. | REPAIR WORKS / Lavori di Ristrutturazione | ||||
| PART I - DEMOLITIONS AND REMOVALS | 0.00 | 0.00 | 0.00 | 0.00 | |
| PART II - ARCHITECTURAL, STRUCTURAL AND CIVIL WORK | 0.00 | 0.00 | 0.00 | 0.00 | |
| PART III - MECHANICAL WORKS | 0.00 | 0.00 | 0.00 | 0.00 | |
| PART IV - ELECTRICAL WORK | 0.00 | 0.00 | 0.00 | 0.00 | |
| SUB TOTAL A / Subtotale A | 0.00 | 0.00 | 0.00 | 0.00 | |
| 0.00 | 0.00 | ||||
| TOTAL PRICE / Costo Totale | 0.00 | 0.00 | 0.00 | 0.00 |
OR US DOLLARS (RATE 1$ = 0,9798€) 0.00 0.00 0.00 0.00
&"Arial,Grassetto"&12FOR OFFICIAL USE ONLY
&"Arial,Grassetto"&12FOR OFFICIAL USE ONLY Sheet &P of &N
GRAND TOTAL
| ASHE 17-1038 - DESIGN FOR REPAIR FAC.1467 FOR AFN AVIANO - AREA F, AVIANO AB, ITALY | 0.9798 |
| INSTRUCTIONS FOR COMPLETING AF FORM 3052 |
| REPAIR WORKS | TOTAL PRICE | |||||||
| TOTAL MATERIAL COSTS | € | 0 | $ | 0 | € | 0.00 | $ | 0.00 |
TOTAL LABOR COSTS € 0 $ 0 € 0.00 $ 0.00
TOTAL OTHER DIRECT COSTS € 0 $ 0 € 0.00 $ 0.00
TOTAL DIRECT COSTS € 0 $ 0 € 0.00 $ 0.00
OVERHEAD € 0 $ 0 € 0.00 $ 0.00
SUBTOTAL € 0 $ 0 € 0.00 $ 0.00
PROFIT € 0 $ 0 € 0.00 $ 0.00
TOTAL PRICE € 0 $ 0 € 0.00 $ 0.00
DATE
TITLE
INSTRUCTIONS TO OFFERORS
&"Arial,Grassetto"&12FOR OFFICIAL USE ONLY
&"Arial,Grassetto"&12FOR OFFICIAL USE ONLY
Col 1 Item. Description of materials required, work to be done, special equipment needed, etc. Breakdown should be in sufficient detail to permit itemizing of all direct costs.
Col 2 Unit of Measure. Description of the unit in which each item is to be estimated (examples - square yards-SY, cubic yards-CY, square feet- SF, linear feet-LF, board feet-BF, each-EA,, pound-LB).
Col 3 Quantity. Contractor's estimated of quantity required in terms of unit of measure (column 2). Item and units of measure will be furnished by the Government. Quantity estimates will be furnished by the Government only when it is anticipated that a unit price contract will be issued. Otherwise, the contractor is responsible for determining quantity estimates.
Col 4 and 5 Material Costs. Enter unit cost (Col 4) of material to be supplied and total cost (Col 5) for item listed in column 1.
Col 6, 7 and 8 Labor Costs. Enter in col 6 the estimated number of manhours or mandays needed to perform the work listed in column 1. Enter in col 7 the average rate per manhour (manday) and in col 8 the total labor cost.
Col 9 Other Direct Costs. Enter estimated costs of special equipment and other items (listed in column 1), which are special to the contract and of significant dollar value.
Col 10 Line. Self-explanatory.
Note: In addition to other totals entered on various pages, the grand total of column 10, plus overhead and profit will be shown on the last page as follows:
1. The purpose of this form is to provide a standard format by which the offeror submits to the Government a summary of incurred and estimated costs, (and attached supporting information) suitable for detailed review and analysis. Prior to the award of a contract resulting from this proposal, the offeror shall, under the conditions stated in ASPR 3-807.3, be required to submit a certificate of current cost or pricing data (see ASPR 3-807.3 and 3-807.4).
2. In addition to the specific information required by this form, the offeror is experted, in good faith, to incorporate in and submit with this form any additional data, supporting schedules, or substation which are reasonably required for the conduct of an appropriate review and analysis in the light of the specific facts of this procurement. For effective negotiations, it is essential that there be a clean understanding of:
a. The existing, verifiable data.
b. The judgmental factors applied in projecting from know data to the estimate, and
c. The contingencies used by the offeror in his proposed price.
In short, the offeror's estimating process itself needs to be disclosed.
3. When attachment of supporting cost or pricing data to this form is impracticable, the data will be described (with schedules as appropriate) and made available to the contracting officer or his authorized representative upon request.
4. By submission of this proposal the offeror grants to the contracting officer, or his authorized representative, the right to examine, for the purpose of verifying the cost or pricing data submitted, those books, records, documents and other supporting data which will permit adequate evaluation of such cost or pricing data, along with the computations and projections used therein. This right may be exercised in connection with any negotiations prior to contract award.
File details come from the government source that posted it. Updated .