This document includes a construction cost estimate breakdown and related federal contract opportunity notice. The cost estimate breakdown provides line item details for repair work to be performed at PAS Z-15 Facility 7850 at Aviano Air Base in Italy. The work includes demolitions, civil and architectural tasks, mechanical work, and electrical work. The total estimated cost is provided in both Euros and US Dollars.

The related federal contract opportunity is a solicitation notice for the ASHE 20-1046 repair project at the same location. Interested vendors must have a current Statement of Capabilities certification in category OG11. The construction value is estimated between $250,000 to $500,000. The scope of work involves repairs detailed in the technical specifications. A site visit will be scheduled for interested firms. The closing date for proposals and award date are not specified. The work must be performed in Italy according to Defense Federal Acquisition Regulation Supplement requirements. The Department of the Air Force United States Air Forces in Europe - Air Forces Africa is the contracting agency.

View the file

Other files

File Type Posted
Amendment FA568220R00170002.pdf PDF
ASHE 20-1046 Addedum 1 REV.1.doc DOC document
ASHE 20-1046 Addedum 2.doc DOC document
ASHE 20-1046 CCEB Rev.2 MDT.xlsx XLSX spreadsheet
Amendment FA568220R00170001.pdf PDF
AVIANO MASTERSPECS 2020.pdf PDF
ASHE 20-1046 DWGs.pdf PDF
PSC - ALLEGATO E - COVID-19.pdf PDF
PSC_Rev02.pdf PDF
Solicitation - FA568220R0017.pdf PDF
ASHE 20-1046 Technical Specifications.pdf PDF
ASHE 20-1046 Addedum 1.doc DOC document
Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ASHE 20-1046

CONSTRUCTION COST ESTIMATE BREAKDOWN
CONTRACTORADDRESS
CONTRACT FOR (Work to be performed)PROPOSED TOTAL CONTRACT PRICE
REPAIR PAS Z-15, FAC. 7850
PURCHASE REQUEST NUMBERPROJECT NUMBERWORK LOCATION
ASHE 20-1046AVIANO AIR BASE, ITALY
MATERIAL COSTSLABOR COSTS
LINE NO.ITEMUNIT OF MEASUREQUANTITYUNITTOTALMANHOURS MANDAYSAVERAGE RATETOTALOTHER DIRECT COSTSLINE TOTAL
(1)(2)(3)(4)(5)(6)(7)(8)(9)(10)
A.REPAIR WORKS / Lavori di Ristrutturazione
PART I - DEMOLITIONS, EXCAVATIONS AND REMOVALS / Parte I - Demolizioni, Scavi e Rimozioni
Ib Architectural Demolitions - Ib Demolizioni Architettoniche0.000.000.00
1REMOVAL OF EXISTING INTERNAL WALL CLADDING
Rimozione rivestimenti murari interni esistentiIT. No. Art. n.1SM/MQ110.54
2REMOVAL OF EXTERNAL WALL COATING
Rimozione rivestimento murario esterno e lavaggio pareteIT. No. Art. n.2SM/MQ195.10
3REMOVAL OF EXISTING FLOOR CARPET, INCLUDED CONCRETE SLAB CLEANING
Rimozione della moquette esistente inclusa la pulizia della soletta in calcestruzzo.IT. No. Art. n.3SM/MQ90.00
4DEMOLITION OF CERAMIC TILES PAVMENT AND CONCRETE SLAB
Demolizione di pavimento in ceramica e sottofondoIT. No. Art. n.4SM/MQ35.00
5REMOVAL SUSPENDED GYPSUM CEILING AND ALL SUSPENDED SYSTEM.
Rimozione controsoffitto in cartongesso inclusa la struttura.IT. No. Art. n.5SM/MQ143.45
6DEMOLITION OF GYPSUM PARTITION INCLUDING WALL CERAMIC TILES
Demolizione tramezze in cartongesso compreso rivestimento ceramicoIT. No. Art. n.6SM/MQ47.60
7REMOVAL OF EXTERNAL METAL DOOR
Rimozione porta esterna in metalloIT. No. Art. n.7aSM/MQ1.15
8CUT EXISTING METAL DOOR
Taglio portone metallicoIT. No. Art. n.7bLS/AC1.00
9REMOVAL OF INTERNAL DOORS
Rimozione porte interneIT. No. Art. n.8SM/MQ13.83
10REMOVAL OF EXISTING TOILETS, TAPS AND FURNISHING
Rimozione sanitari, lavabi, rubinetterie e arredi esistentiIT. No. Art. n.9LS/AC1.00
Total Architectural Demolitions - Totale Demolizioni Architettoniche
Id Mechanical Demolitions - Id Demolizioni Meccaniche
11Complete removal of the part of existing supply and return ductwork from AHU-1 serving the ground floor warehouse internal offices
Rimozione completa della parte di canalizzazioni provenienti dall'AHU-1 a servizio degli uffici interni del magazzino al piano terraIT. No. Art. n.10EA/NO1.00
12Partial removal of existing supply and return ductwork from AHU-2 serving the ground floor warehouse internal offices
Rimozione parziale delle canalizzazioni provenienti dall'AHU-2 a servizio degli uffici interni del magazzino al piano terraIT. No. Art. n.11EA/NO1.00
Total Mechanical Demolitions - Totale Demolizioni Meccaniche
Ie Electrical Demolitions - Ie Demolizioni Elettriche
13REMOVAL OF THE EXISTING PANELBOARDS, MAIN DISTRIBUTUTION WIREWAYS AND CABLES
Rimozione dei quadri elettrici, delle canalizzazioni e dei cavi principali di distribuzione esistentiIT. No. Art. n.12aLS/AC1.00
14REMOVAL OF THE EXISTING LIGHTING AND POWER SYSTEMS, INCLUDED ASSOCIATED TERMINAL CONDUITS, CABLES, RECEPTACLES, CONTROLS, ETC.
Rimozione degli impianti illuminazione ed energia esistenti, comprese condutture terminali associate, prese, comandi, ecc.IT. No. Art. n.12bLS/AC1.00
15REMOVAL OF THE EXISTING TELECOMMUNICATION SYSTEM, INCLUDED ASSOCIATED TERMINAL CONDUITS AND CABLES, DROPS, BOXES, ETC.
Rimozione dell'impianto di cablaggio strutturato, comprese condutture terminali associate, prese, scatole, ecc.IT. No. Art. n.12cLS/AC1.00
16EXECUTION OF TRACES ON CONCRETE AND MASONRY WALLS AND CELING, TO ENCASE NEW CONDUITS TO SUPPLY NEW RECEPTACLES. EXECUTION OF HOLES THROUGH WALLS TO DISTRIBUTE NEW CONDUITS AND CABLETRAYS.
Esecuzione di tracce su pareti e soffitti in calcestruzzo e muratura, per incassare nuove tubazioni per collegare nuove prese. Esecuzione di opere murarie per attraversamento di pareti da parte di nuovi canali e tubazioni.IT. No. Art. n.12dLS/AC1.00
Total Electrical Demolitions - Totale Demolizioni Elettriche

TOTAL PART I / Totale Parte I

PART II - CIVIL, ARCHITECTURAL & STRUCTURAL WORK / Parte II - Lavori Civili, Architettonici e Strutturali
IIb Architectural Works - IIb Lavori Architettonici
17GROUTING INTERNAL WALLS
Stuccatura muri interniIT. No. Art. n.1aSM/MQ539.36
18APPLY PAINT BASECOAT ON INTERNAL WALLS
Applicazione di fissativo per pitture su muri interniIT. No. Art. n.1bSM/MQ539.36
19INTERNAL WALLS PAINTING WITH WASHABLE PAINT - 3 LAYER
Tinteggiatura pareti interne - 3 maniIT. No. Art. n.1cSM/MQ539.36
20WALL CERAMIC TILES
Rivestimento ceramico paretiIT. No. Art. n.2SM/MQ116.16
21PREPARE CONCRET SLAB FOR MOQUETTE APPLICATION
Preparazione del sottofondo per posa in opera moquetteIT. No. Art. n.3aSM/MQ90.00
22SUPPLY AND APPLY FLOOR CARPET
Fornitura e posa in opera di moquetteIT. No. Art. n.3bSM/MQ90.00
23PROVIDE AND INSTALL VYNILIC BASEBOARD
Fornitura e posa in opera di battiscopa in vinile/pvcIT. No. Art. n.3cLM/ML82.40
24CONCRETE SCREED (Th. 6cm)
Formazione caldana in sabbia e cemento (Spessore 6cm)IT. No. Art. n.4SM/MQ35.00
25ANTI-SLIP CERAMIC TILES DIM.20x20cm
Piastrelle in ceramica con finitura antiscivolo dim. 20x20cmIT. No. Art. n.5SM/MQ35.00
26MINERAL FIBER SUSPENDED CEILING (600X600mm)
Controsoffitto in lana minerale (600X600mm)IT. No. Art. n.6SM/MQ103.45
27SOUNDPROOF DOUBLE LAYER (12,5+12,5mm) GYPSUM BOARD PARTITIONS
Costruzione di pareti in cartongesso fonoisolanti con doppie lastre da 12.5mmIT. No. Art. n.7aSM/MQ81.78
28SURCHARGE FOR MOISTURE RESISTANT GYPSUM
Sovrapprezzo per uso lastre idrorepellentiIT. No. Art. n.7bSM/MQ103.58
29EXTERNAL PLASTER WITH REINFORCED WIRE
Rasatura esterna con rete annegataIT. No. Art. n.8aSM/MQ195.10
30ACRYL-SILOSSANIC WALL COATING - GRANULOMETRY 3mm
Rivestimento acril-silossanico - granulometria 3mmIT. No. Art. n.8bSM/MQ195.10
31PROVIDE AND INSTALL STEEL SQUARE TUBE FRAME
Fornitura e posa in opera di tubolari quadri in acciaioIT. No. Art. n.9aKG/KG53.31
32PROVIDE AND INSTALL SOUNDPROOF METAL DOOR FOR INTERNAL/EXTERNAL
Fornitura e posa in opera di porta metallica coibentata per interni/esterniIT. No. Art. n.9bEA/NO2.00
33STAINLESS STEEL PANIC HARDWARE
Maniglione antipanico in acciaio a barra incorporataIT. No. Art. n.9cEA/NO1.00
34EXTERNAL ANTI-SLIP METAL RAMP
Rampa metalica esterna anti scivoloIT. No. Art. n.9eEA/NO1.00
35PROVIDE AND INSTALL INTERNAL DOORS
Fornitura e posa in opera di porte interneIT. No. Art. n.10SM/MQ15.12
36ROTATE AND REINSTALL EXISTING DOOR ROOM 3A
Ruotare e riposizionare porta esistente stanza 3AIT. No. Art. n.11LS/AC1.00
37METAL "MARINARA" STAIRCASE
Scala metallica alla "marinara"IT. No. Art. n.12LM/ML3.50
38METAL RAILING
Parapetto metallicoIT. No. Art. n.13KG/KG348.86
39STAINLESS STEEL ANTI-BIRD NETTING
Rete parapassero in acciaio inoxIT. No. Art. n.14KG/KG9.90
40LIQUID SOAP DISPENSER
Dispensatore sapone liquidoIT. No. Art. n.15aEA/NO2.00
41TOILET PAPER HOLDER
Contenitore carta igienicaIT. No. Art. n.15bEA/NO7.00
42140x90 CM MIRROR W/STAINLESS STEEL FRAME
Specchio con cornice in acciaio inossidabile 140x90 cmIT. No. Art. n.15cEA/NO1.00
43ROBE HOOK - DOUBLE
Gancio appendiabiti - DoppiIT. No. Art. n.15dEA/NO1.00
44PAPER TOWEL DISPENSER, AUTOCUT TYPE
Dispensatore salviette di carta, taglio automaticoIT. No. Art. n.15eEA/NO1.00
Total Architectural - Totale Architettonici

TOTAL PART II / Totale Parte II

PART III - MECHANICAL WORK / Parte III - Lavori Meccanici
IIIa HVAC - IIIa HVAC
45Supply and installation of pre-insulated aluminium HVAC ductwork
Fornitura e installazione di condotte HVAC preisolate rivestite in alluminioIT. No. Art. n.1SM/MQ90.00
46Supply and installation of bell mount supply air terminals, type Brofer BM or similar
Fornitura e installazione di bocchette di mandata dell'aria, tipo Brofer BM o similariIT. No. Art. n.2EA/NO9.00
47Supply and installation of bell mount return terminals, type Brofer LAF or similar
Fornitura e installazione di bocchette di ritorno dell'aria, tipo Brofer KAF o similariIT. No. Art. n.3EA/NO4.00
48Supply and installation of exhaust valves, type Brofer EAV-CR or similar
Fornitura e installazione di valvole di estrazione, tipo Brofer EAV-CR o similariIT. No. Art. n.4.aEA/NO7.00
49Supply and installation of exhaust valves, type Brofer EAV-CR or similar
Fornitura e installazione di valvole di estrazione, tipo Brofer EAV-CR o similariIT. No. Art. n.4.bEA/NO2.00
50Supply and installation of air transfer grille, type Brofer GTA or similar
Fornitura e installazione di griglia di transito, tipo Brofer GTA o similariIT. No. Art. n.5.aEA/NO1.00
51Supply and installation of air transfer grille, type Brofer GTA or similar
Fornitura e installazione di griglia di transito, tipo Brofer GTA o similariIT. No. Art. n.5.bEA/NO1.00
52Supply and installation of new condensing unit for Variable Refrigerant Volume system, brand DAIKIN model RXYQ14U or similar
Fornitura e installazione di una nuova unità di condensazione per sistema di volume di refrigerante variabile, marca DAIKIN modello RXYQ14U o simileIT. No. Art. n.6EA/NO1.00
53Supply and installation of new condensing unit for outdoor installation for R32 heat pump inverter, brand DAIKIN model RZA200D or similar
Fornitura e installazione di nuova unità di condensazione per installazione esterna gas R32 pompa di calore inverter, marca DAIKIN modello RZA200D o simileIT. No. Art. n.7EA/NO1.00
54Supply and installation of indoor units for wall installation for VRV system at R410A, brand DAIKIN model FXAQ63A or similar
Fornitura e installazione di unità interne per installazione a parete per sistema VRV a R410A, marca DAIKIN modello FXAQ63A o simileIT. No. Art. n.8.aEA/NO3.00
55Supply and installation of indoor units for wall installation for VRV system at R410A, brand DAIKIN model FXAQ20A or similar
Fornitura e installazione di unità interne per installazione a parete per sistema VRV a R410A, marca DAIKIN modello FXAQ20A o simileIT. No. Art. n.8.bEA/NO1.00
56Supply and installation of indoor units for wall installation for VRV system at R410A, brand DAIKIN model FXAQ50A or similar
Fornitura e installazione di unità interne per installazione a parete per sistema VRV a R410A, marca DAIKIN modello FXAQ50A o simileIT. No. Art. n.8.cEA/NO3.00
57Supply and installation of indoor units for for wall-mounted heat pump installation, brand DAIKIN model FAAQ100A or similar
Fornitura e installazione di unità interne per installazione a parete per sistema in pompa di calore, marca DAIKIN modello FAAQ100A o simileIT. No. Art. n.9EA/NO2.00
58Supply and installation of Indoor Unit Heaters for wall-mounted hydronic installation, consisting of Helical air heater with electronic motor and inverter, brand SABIANA model ATLAS A-ECM 13 or similar
Fornitura e installazione di aerotermo idronico per installazione a parete, completo di ventola elicoidale e motore elettronico con inverter, marca SABIANA modello ATLAS A-ECM 13 o simileIT. No. Art. n.10EA/NO2.00
59Supply and installation of new VFD with necessary electrical panel, cables and conduits, final connection and testing for AHU-1 supply fan, 4,0 kW
Fornitura e installazione di nuovo VFD completo di quadro elettrico, cavi e condotti necessari, connessione finale e test per ventilatore di mandata AHU-1, 4,0 kWIT. No. Art. n.11.aEA/NO1.00
60Supply and installation of new VFD with necessary electrical panel, cables and conduits, final connection and testing for AHU-1 return fan, 1,5 kW
Fornitura e installazione di nuovo VFD completo di quadro elettrico, cavi e condotti necessari, connessione finale e test per ventilatore di ripresa AHU-1, 1,5 kWIT. No. Art. n.11.bEA/NO1.00
61Supply and installation of new VFD with necessary electrical panel, cables and conduits, final connection and testing for AHU-2 supply fan, 2,2 kW
Fornitura e installazione di nuovo VFD completo di quadro elettrico, cavi e condotti necessari, connessione finale e test per ventilatore di mandata AHU-2, 2,2 kWIT. No. Art. n.11.cEA/NO1.00
62Supply and installation of new VFD with necessary electrical panel, cables and conduits, final connection and testing for AHU-2 return fan, 0,75 kW
Fornitura e installazione di nuovo VFD completo di quadro elettrico, cavi e condotti necessari, connessione finale e test per ventilatore di ripresa AHU-2, 0,75 kWIT. No. Art. n.11.dEA/NO1.00
63Supply and installation of new supervision software, suitable with DDC hardware system and specification, complete with all necessaries accessories
Fornitura e installazione di nuovo software di supervisione, adatto per gli impianti presenti e coerente con le specifiche hardware DDC, completo di tutti gli accessoriIT. No. Art. n.12EA/NO1.00
64Supply of all ductwork system testing and balancing with new design air flow rate as per mechanical drawings and specification
Fornitura del servizio completo di test e bilanciamento degli impianti HVCA in accordo con il progetto degli impianti meccanici e specificheIT. No. Art. n.13EA/NO1.00
Total HVAC - Totale HVAC
0
IIIb Plumbing System - IIIb Impianto idricosanitario e scarico
65Supply and installation of all new condensate drain pipes system for all new DX units.
Fornitura e installazione del sistema di drenaggio condensa per le nuove unità DX.IT. No. Art. n.14EA/NO1.00
66Supply and installation of a new condensate drain pump to be connected to condensate drain pipes for warehouse offices, type Smart Flow SF-30lt or similar.
Fornitura e installazione di una nuova pompa per drenaggio condensa delle unità split degli uffici del magazzino, tipo Smart Flow SF-30lt o similare.IT. No. Art. n.15EA/NO1.00
67Supply and installation of a suspended water close with flushing concealed box and sewage and water pipes..
Fornitura e installazione di wc sospeso completo di supporti , cassetta di risciaquo da incasso, tubazioni di scarico ed adduzione idrica.IT. No. Art. n.16EA/NO7.00
68Supply and installation of a wall-mounted washbasin, complete with sewage and water pipes, and battery electronic basin mixer group with infrared sensor .
Fornitura e installazione di lavabo a parete completo di tubazioni di scarico ed adduzione idrica, e miscelatore elettronico ad infrarossi a batteria.IT. No. Art. n.17EA/NO2.00
69Supply and installation of a floor-mounted mopsink, complete with sewage and water pipes, and basin mixer group.
Fornitura e installazione di lavabo a parete completo di tubazioni di scarico ed adduzione idrica, e gruppo miscelatore.IT. No. Art. n.18EA/NO1.00
Total Plumbing System - Totale Impianto idricosanitario e scarico

TOTAL PART III / Totale Parte III

PART IV - ELECTRICAL WORK / Parte IV - Lavori Elettrici

70FURNISHING AND INSTALLATION OF PANELBOARDS: MDP
Fornitura e posa in opera di quadri elettrici: MDPIT. No. Art. n.1aEA/NO1.00
71FURNISHING AND INSTALLATION OF PANELBOARDS: PANEL "D"
Fornitura e posa in opera di quadri elettrici: Panel "D"IT. No. Art. n.1bEA/NO1.00
72FURNISHING AND INSTALLATION OF PANELBOARDS: PANEL "F"
Fornitura e posa in opera di quadri elettrici: Panel "F"IT. No. Art. n.1cEA/NO1.00
73FURNISHING AND INSTALLATION OF PANELBOARDS: PANEL "C"
Fornitura e posa in opera di quadri elettrici: Panel "C"IT. No. Art. n.1dEA/NO1.00
74FURNISHING AND INSTALLATION OF PANELBOARDS: PANEL "PB.COMM"
Fornitura e posa in opera di quadri elettrici: Panel "PB.COMM"IT. No. Art. n.1eEA/NO1.00
75FURNISHING AND INSTALLATION OF PANELBOARDS: PANEL "GE"
Fornitura e posa in opera di quadri elettrici: Panel "GE"IT. No. Art. n.1eEA/NO1.00
76WALL MOUNTED PUSH-BUTTON
Pulsante di sgancioIT. No. Art. n.2aEA/NO1.00
77FURNISHING AND INSTALLATION OF CABLES: FG16R16 1x16 sq.mm
Fornitura e posa in opera di cavi: FG16R16 1x16 mmqIT. No. Art. n.3aLM/ML15.00
78FURNISHING AND INSTALLATION OF CABLES: FG16R16 1x25 sq.mm
Fornitura e posa in opera di cavi: FG16R16 1x25 mmqIT. No. Art. n.3bLM/ML50.00
79FURNISHING AND INSTALLATION OF CABLES: FG16R16 1x50 sq.mm
Fornitura e posa in opera di cavi: FG16R16 1x50 mmqIT. No. Art. n.3cLM/ML50.00
80FURNISHING AND INSTALLATION OF CABLES: FG16R16 1x70 sq.mm
Fornitura e posa in opera di cavi: FG16R16 1x70 mmqIT. No. Art. n.3dLM/ML15.00
81FURNISHING AND INSTALLATION OF CABLES: FG16R16 1x120 sq.mm
Fornitura e posa in opera di cavi: FG16M16 1x120 mmqIT. No. Art. n.3eLM/ML45.00
82FURNISHING AND INSTALLATION OF CABLES: FG16OR16 2x1.5 sq.mm
Fornitura e posa in opera di cavi: FG16OR16 2x1.5 mmqIT. No. Art. n.3fLM/ML430.00
83FURNISHING AND INSTALLATION OF CABLES: FG16OR16 3G1.5 sq.mm
Fornitura e posa in opera di cavi: FG16OR16 3Gx1.5 mmqIT. No. Art. n.3gLM/ML120.00
84FURNISHING AND INSTALLATION OF CABLES: FG16OR16 3G2.5 sq.mm
Fornitura e posa in opera di cavi: FG16OR16 3G2.5 mmqIT. No. Art. n.3hLM/ML160.00
85FURNISHING AND INSTALLATION OF CABLES: FG16OR16 3G4 sq.mm
Fornitura e posa in opera di cavi: FG16OR16 3G4 mmqIT. No. Art. n.3iLM/ML530.00
86FURNISHING AND INSTALLATION OF CABLES: FG16OR16 3G6 sq.mm
Fornitura e posa in opera di cavi: FG16OR16 3G6 mmqIT. No. Art. n.3jLM/ML10.00
87FURNISHING AND INSTALLATION OF CABLES: FG16OR16 4G1.5 sq.mm
Fornitura e posa in opera di cavi: FG16OR16 4G1.5 mmqIT. No. Art. n.3kLM/ML9.00
88FURNISHING AND INSTALLATION OF CABLES: FG16OR16 4G2.5 sq.mm
Fornitura e posa in opera di cavi: FG16OR16 4G2.5 mmqIT. No. Art. n.3lLM/ML12.00
89FURNISHING AND INSTALLATION OF CABLES: FG16OR16 5G2.5 sq.mm
Fornitura e posa in opera di cavi: FG16OR16 5G2.5 mmqIT. No. Art. n.3mLM/ML9.00
90FURNISHING AND INSTALLATION OF CABLES: FG16OR16 5G4 sq.mm
Fornitura e posa in opera di cavi: FG16OR16 5G4 mmqIT. No. Art. n.3nLM/ML70.00
91FURNISHING AND INSTALLATION OF CABLES: FG16OR16 5G6 sq.mm
Fornitura e posa in opera di cavi: FG16OR16 5G6 mmqIT. No. Art. n.3oLM/ML35.00
92FURNISHING AND INSTALLATION OF CABLES: FG16OR16 5G10 sq.mm
Fornitura e posa in opera di cavi: FG16OR16 5G10 mmqIT. No. Art. n.3pLM/ML80.00
93FURNISHING AND INSTALLATION OF CABLES: FG16OR16 5G16 sq.mm
Fornitura e posa in opera di cavi: FG16OR16 5G16 mmqIT. No. Art. n.3qLM/ML9.00
94FURNISHING AND INSTALLATION OF CABLES: FG16OR16 5G25 sq.mm
Fornitura e posa in opera di cavi: FG16OR16 5G25 mmqIT. No. Art. n.3rLM/ML21.00
95FURNISHING AND INSTALLATION OF CABLES: FG18OM16 2x1.5 sq.mm
Fornitura e posa in opera di cavi: FG18OM16 2x1.5 mmqIT. No. Art. n.3sLM/ML6.00
96FURNISHING AND INSTALLATION OF CABLES: FG16OH2R16 4G2.5 sq.mm
Fornitura e posa in opera di cavi: FG16OH2R16 4G2.5 mmqIT. No. Art. n.3tLM/ML20.00
97FURNISHING AND INSTALLATION OF CABLES: FS17 1x1.5 sq.mm
Fornitura e posa in opera di cavi: FS17 1x1.5 mmqIT. No. Art. n.3uLM/ML180.00
98FURNISHING AND INSTALLATION OF CABLES: FS17 1x2.5 sq.mm
Fornitura e posa in opera di cavi: FS17 1x2.5 mmqIT. No. Art. n.3vLM/ML240.00
99FURNISHING AND INSTALLATION OF CABLES: FS17 1x4 sq.mm
Fornitura e posa in opera di cavi: FS17 1x4 mmqIT. No. Art. n.3wLM/ML210.00
100FURNISHING AND INSTALLATION OF CABLES: FS17 1x16 sq.mm
Fornitura e posa in opera di cavi: FS17 1x16 mmqIT. No. Art. n.3xLM/ML9.00
101FURNISHING AND INSTALLATION OF CABLES: FS17 1x50 sq.mm
Fornitura e posa in opera di cavi: FS17 1x50 mmqIT. No. Art. n.3yLM/ML40.00
102FURNISHING AND INSTALLATION OF CABLES: FS17 1x70 sq.mm
Fornitura e posa in opera di cavi: FS17 1x50 mmqIT. No. Art. n.3zLM/ML15.00
103FURNISHING AND INSTALLATION OF CABLE TRAY, IP4X: FeZn 100x75 mm
Fornitura e posa in opera di canale portacavi: FeZn 100x75 mm, IP4XIT. No. Art. n.4aLM/ML12.00
104FURNISHING AND INSTALLATION OF CABLE TRAY: FeZn 150x75 mm, IP4X
Fornitura e posa in opera di canale portacavi: FeZn 150x75 mm, IP4XIT. No. Art. n.4bLM/ML51.00
105FURNISHING AND INSTALLATION OF CABLE TRAY: FeZn 200x75 mm, IP4X
Fornitura e posa in opera di canale portacavi: FeZn 200x75 mm, IP4XIT. No. Art. n.4cLM/ML6.00
106FURNISHING AND INSTALLATION OF BASKET TRAY: FeZn 150x75 mm
Fornitura e posa in opera di canale portacavi filo acciaio: FeZn 150x75 mmIT. No. Art. n.5aLM/ML114.00
107FURNISHING AND INSTALLATION OF BASKET TRAY: FeZn 300x75 mm
Fornitura e posa in opera di canale portacavi filo acciaio: FeZn 300x75 mmIT. No. Art. n.5bLM/ML6.00
108FURNISHING AND INSTALLATION OF BASKET TRAY: FeZn 400x75 mm
Fornitura e posa in opera di canale portacavi filo acciaio: FeZn 400x75 mmIT. No. Art. n.5cLM/ML15.00
109FURNISHING AND INSTALLATION OF BASKET TRAY: FeZn 500x75 mm
Fornitura e posa in opera di canale portacavi filo acciaio: FeZn 500x75 mmIT. No. Art. n.5dLM/ML21.00
110FURNISHING AND INSTALLATION OF PLIABLE PVC CONDUITS: Ø 20 mm
Fornitura e posa in opera di tubi PVC pieghevoli: Ø 20 mmIT. No. Art. n.6aLM/ML30.00
111FURNISHING AND INSTALLATION OF PLIABLE PVC CONDUITS: Ø 25 mm
Fornitura e posa in opera di tubi PVC pieghevoli: Ø 25 mmIT. No. Art. n.6bLM/ML36.00
112FURNISHING AND INSTALLATION OF PLIABLE PVC CONDUITS: Ø 32 mm
Fornitura e posa in opera di tubi PVC pieghevoli: Ø 32 mmIT. No. Art. n.6cLM/ML12.00
113FURNISHING AND INSTALLATION OF RIGID PVC CONDUITS: Ø 20 mm
Fornitura e posa in opera di tubi PVC rigidi: Ø 20 mmIT. No. Art. n.7aLM/ML21.00
114FURNISHING AND INSTALLATION OF RIGID PVC CONDUITS: Ø 25 mm
Fornitura e posa in opera di tubi PVC rigidi: Ø 25 mmIT. No. Art. n.7bLM/ML54.00
115FURNISHING AND INSTALLATION OF RIGID PVC CONDUITS: Ø 32 mm
Fornitura e posa in opera di tubi PVC rigidi: Ø 32 mmIT. No. Art. n.7cLM/ML18.00
116FURNISHING AND INSTALLATION OF RIGID PVC CONDUITS: Ø 40 mm
Fornitura e posa in opera di tubi PVC rigidi: Ø 40 mmIT. No. Art. n.7dLM/ML9.00
117FURNISHING AND INSTALLATION OF RIGID METALLIC CONDUITS: Ø 20 mm
Fornitura e posa in opera di tubi rigidi metallici: Ø 20 mmIT. No. Art. n.8aLM/ML15.00
118FURNISHING AND INSTALLATION OF RIGID METALLIC CONDUITS: Ø 25 mm
Fornitura e posa in opera di tubi rigidi metallici: Ø 25 mmIT. No. Art. n.8bLM/ML72.00
119FURNISHING AND INSTALLATION OF RIGID METALLIC CONDUITS: Ø 32 mm
Fornitura e posa in opera di tubi rigidi metallici: Ø 32 mmIT. No. Art. n.8cLM/ML48.00
120FURNISHING AND INSTALLATION OF RIGID METALLIC CONDUITS: Ø 40 mm
Fornitura e posa in opera di tubi rigidi metallici: Ø 40 mmIT. No. Art. n.8dLM/ML57.00
121MASONRY AND CONSTRUCTION WORK ASSISTANCES
Fornitura e posa in opera di assistenze ediliIT. No. Art. n.9aAC/LS1.00
122FURNISHING AND INSTALLATION OF FIRESTOPPING BARRIERS
Fornitura e posa in opera di barriere tagliafuocoIT. No. Art. n.10aAC/LS1.00
123GROUNDING SYSTEM: COPPER WIRE BARE, 50 sq.mm
Impianto di terra: corda di rame nuda, 50 mmqIT. No. Art. n.11aLM/ML40.00
124GROUNDING SYSTEM: MAIN GROUND BAR "MGB"
Impianto di terra: barra di terra principale "MGB"IT. No. Art. n.11bEA/NO1.00
125GROUNDING SYSTEM: MAIN TELECOM GROUND BAR "TMGB"
Impianto di terra: barra di terra principale "TMGB"IT. No. Art. n.11cEA/NO1.00
126GROUNDING SYSTEM: BONDING
Impianto di terra: collegamenti equipotenzialiIT. No. Art. n.11dAC/LS1.00
127POWER RECEPTACLES: P17/11 + P40, ENCASED IN WALL
Prese di energia: tipo P17/11 + P40, incassate a pareteIT. No. Art. n.12aEA/NO6.00
128POWER RECEPTACLES: P17/11 + P40, EXPOSED ON WALL
Prese di energia: tipo P17/11 + P40, esposte a pareteIT. No. Art. n.12bEA/NO11.00
129POWER RECEPTACLE: P40 type
Prese di energia: tipo P40IT. No. Art. n.12cEA/NO2.00
130POWER RECEPTACLE: P17/11 + 10A AUTOMATIC PROTECTION, ENCASED IN WALL
Presa di energia: P17/11 + interruttore automatico 10A, incassati a pareteIT. No. Art. n.12dEA/NO3.00
131POWER RECEPTACLE: P17/11 + 10A AUTOMATIC PROTECTION, ENCASED IN WALL, WEATHER-PROOF IP55
Presa di energia: P17/11 + interruttore automatico 10A, incassati a parete, grado di protezione IP55IT. No. Art. n.12eEA/NO3.00
132POWER RECEPTACLE: P17/11 + 0.01A GFI, ENCASED IN WALL, WEATHER-PROOF IP55
Presa di energia: P17/11 + interruttore differenziali 0.01A, incassati a parete, grado di protezione IP55IT. No. Art. n.12fEA/NO3.00
133"WS" POWER RECEPTACLES: #2 BOXES EACH WITH #1 P17/11 RECEPTACLE + #1 P40 RECEPTACLE. ENCASED IN WALL
"WS" Prese di energia: n°2 scatole ciascuna contenente n°1 presa P17/11 + n°1 presa P40. Incassate a pareteIT. No. Art. n.12gEA/NO17.00
134"WS" POWER RECEPTACLES: #2 BOXES EACH WITH #1 P17/11 RECEPTACLE + #1 P40 RECEPTACLE. EXPOSED ON WALL
"WS" Prese di energia: n°2 scatole ciascuna contenente n°1 presa P17/11 + n°1 presa P40. Esposte a pareteIT. No. Art. n.12hEA/NO28.00
135POWER RECEPTACLE: P40 type, IP55, WITH WEATHER-PROOF WHILE-IN-USE COVER
Presa di energia: tipo P40, IP55, con coperchio stagno in funzionamentoIT. No. Art. n.12iEA/NO1.00
136INDUSTRIAL POWER RECEPTACLE: 2x16A+G IEC309 type receptacle
Presa di energia industriale: 2x16A+T tipo IEC309IT. No. Art. n.12jEA/NO1.00
137VERTICAL ALUMINUM COLUMN FOR POWER DISTRIBUTION
Colonna verticale in alluminio per distribuzione energiaIT. No. Art. n.12kEA/NO3.00
138ORDINARY MAINTENANCE OF RECEPTACLES IN METALLIC ENCLOSURE
Manutenzione generale delle prese esistenti in custodia metallicaIT. No. Art. n.12lLs/AC1.00
139POWER CONNECTION: "FC" FANCOIL
Collegamento di energia: "FC" ventilconvettoreIT. No. Art. n.13aEA/NO9.00
140POWER CONNECTION: "PHP" HEAT PUMP
Collegamento di energia: "PHP" pompa di caloreIT. No. Art. n.13bEA/NO3.00
141POWER CONNECTION: "DALI"
Collegamento di energia: "DALI"IT. No. Art. n.13cEA/NO1.00
142POWER CONNECTION: "NIPRNET" CABINET
Collegamento di energia: armadio "NIPRNET"IT. No. Art. n.13dEA/NO1.00
143POWER CONNECTION: "SIPRNET & BICES" CABINET
Collegamento di energia: armadio "SIPRNET & BICES"IT. No. Art. n.13eEA/NO7.00
144LIGHTING SYSTEM: TOGGLE SWITCH
Impianto illuminazione: interruttoreIT. No. Art. n.14aEA/NO1.00
145LIGHTING SYSTEM: TOGGLE SWITCH, WEATHER-PROOF TYPE
Impianto illuminazione: interruttore, stagnoIT. No. Art. n.14bEA/NO1.00
146LIGHTING SYSTEM: 2-WAY TOGGLE SWITCH
Impianto illuminazione: deviatoreIT. No. Art. n.14cEA/NO2.00
147LIGHTING SYSTEM: PUSH BUTTON
Impianto illuminazione: pulsanteIT. No. Art. n.14dEA/NO14.00
148LIGHTING SYSTEM: #4 PUSH BUTTONS IN THE SAME BOX
Impianto illuminazione: n°4 pulsanti nella stessa scatolaIT. No. Art. n.14eEA/NO1.00
149LIGHTING SYSTEM: CONNECTION POINT
Impianto illuminazione: punto luceIT. No. Art. n.14fEA/NO38.00
150LIGHTING SYSTEM: ON/OFF TYPE OCCUPANCY SENSOR
Impianto illuminazione: sensore di movimento ON/OFFIT. No. Art. n.14gEA/NO26.00
151LIGHTING SYSTEM: ORDINARY MAINTENANCE OF SWITCHES AND PUSH BUTTONS IN METALLIC ENCLOSURES
Impianto illuminazione: manutenzione ordinaria di interruttori e pulsanti in custodia metallicaIT. No. Art. n.14hLs/AC1.00
152LIGHTING SYSTEM: DUST-TO-DOWN SENSOR
Impianto illuminazione: sensore crepuscolareIT. No. Art. n.14iEA/NO1.00
153LIGHTING SYSTEM: "A1" TYPE LIGHTING FIXTURE
Impianto illuminazione: corpo luce tipo "A1"IT. No. Art. n.15aEA/NO2.00
154LIGHTING SYSTEM: "A1" TYPE LIGHTING FIXTURE, REDUCED EMISSION
Impianto illuminazione: corpo luce tipo "A1", emissione ridottaIT. No. Art. n.15bEA/NO4.00
155LIGHTING SYSTEM: "A2" TYPE LIGHTING FIXTURE
Impianto illuminazione: corpo luce tipo "A2"IT. No. Art. n.15cEA/NO25.00
156LIGHTING SYSTEM: "B1" TYPE LIGHTING FIXTURE
Impianto illuminazione: corpo luce tipo "B1"IT. No. Art. n.15dEA/NO10.00
157LIGHTING SYSTEM: "C1" TYPE LIGHTING FIXTURE
Impianto illuminazione: corpo luce tipo "C1"IT. No. Art. n.15eEA/NO13.00
158LIGHTING SYSTEM: "C2" TYPE LIGHTING FIXTURE
Impianto illuminazione: corpo luce tipo "C2"IT. No. Art. n.15fEA/NO6.00
159LIGHTING SYSTEM: "D1" TYPE LIGHTING FIXTURE
Impianto illuminazione: corpo luce tipo "D1"IT. No. Art. n.15gEA/NO2.00
160LIGHTING SYSTEM: "F1" TYPE LIGHTING FIXTURE
Impianto illuminazione: corpo luce tipo "F1"IT. No. Art. n.15hEA/NO4.00
161LIGHTING SYSTEM: "F2" TYPE LIGHTING FIXTURE
Impianto illuminazione: corpo luce tipo "F2"IT. No. Art. n.15iEA/NO17.00
162LIGHTING SYSTEM: "G1" TYPE LIGHTING FIXTURE
Impianto illuminazione: corpo luce tipo "G1"IT. No. Art. n.15jEA/NO3.00
163EMERGENCY LIGHTING SYSTEM: 600 lm OUTPUT FIXTURE TYPE
Impianto illuminazione: emissione 600 lmIT. No. Art. n.16aEA/NO6.00
164EMERGENCY LIGHTING SYSTEM TEST
Impianto illuminazione emergenza: sistema di testIT. No. Art. n.16bAC/LS1.00
165DALI SYSTEM DEVICE: MINI INPUT UNIT INTERFACE
Componenti impianto DALI: interfaccia contatti miniaturizzataIT. No. Art. n.17aEA/NO11.00
166DALI SYSTEM DEVICE: SINGLE CHANNEL SIGNAL RELAY UNIT
Componenti impianto DALI: relè singolo canaleIT. No. Art. n.17bEA/NO1.00
167DALI SYSTEM DEVICE: ROUTER
Componenti impianto DALI: routerIT. No. Art. n.17cEA/NO2.00
168DALI SYSTEM DEVICE: MULTISENSOR
Componenti impianto DALI: multi-sensoreIT. No. Art. n.17dEA/NO17.00
169NIPRNET SYSTEM DOUBLE DROPS, U/FTP CAT.6, RECESSED IN WALL
Impianto NIPRNET: doppia presa, tipo U/FTP Cat. 6, incassata a pareteIT. No. Art. n.18aEA/NO14.00
170NIPRNET SYSTEM DOUBLE DROPS, U/FTP CAT.6, EXPOSED ON WALL
Impianto NIPRNET: doppia presa, tipo U/FTP Cat. 6, esposta a pareteIT. No. Art. n.18bEA/NO13.00
171NIPRNET SYSTEM DOUBLE DROPS, U/FTP CAT.6, EXPOSED ON WALL, IP55.
Impianto NIPRNET: doppia presa, tipo U/FTP Cat. 6, esposta a parete, IP55IT. No. Art. n.18cEA/NO1.00
172SIPRNET SYSTEM DOUBLE DROPS, U/FTP CAT.6, RECESSED IN WALL
Impianto NIPRNET: doppia presa, tipo U/FTP Cat. 6, incassata a pareteIT. No. Art. n.18dEA/NO19.00
173SIPRNET SYSTEM DOUBLE DROPS, U/FTP CAT.6, EXPOSED ON WALL
Impianto NIPRNET: doppia presa, tipo U/FTP Cat. 6, esposta a pareteIT. No. Art. n.18eEA/NO22.00
174SIPRNET SYSTEM DOUBLE DROPS, U/FTP CAT.6, EXPOSED ON WALL, IP55.
Impianto NIPRNET: doppia presa, tipo U/FTP Cat. 6, esposta a parete, IP55.IT. No. Art. n.18fEA/NO1.00
175BICES SYSTEM DOUBLE DROPS, U/FTP CAT.6, EXPOSED ON WALL
Impianto BICES: doppia presa, tipo U/FTP Cat. 6, incassata a pareteIT. No. Art. n.18gEA/NO1.00
176BICES SYSTEM DOUBLE DROPS, U/FTP CAT.6, RECESSED IN WALL
Impianto BICES: doppia presa, tipo U/FTP Cat. 6, esposta a pareteIT. No. Art. n.18hEA/NO7.00
177VERTICAL ALUMINUM COLUMN FOR DATA DROPS DISTRIBUTION
Colonna verticale in alluminio per distribuzione prese datiIT. No. Art. n.18iEA/NO6.00
178TELECOMM. SYSTEM: CABLE U/FTP CAT.6, green color, for NIPRnet
Impianto trasmissione dati: cavo tipo U/FTP Cat. 6, guaina verde, per NIPRnetIT. No. Art. n.19aLM/ML2,520.00
179TELECOMM. SYSTEM: CABLE U/FTP CAT.6, red color, for SIPRnet
Impianto trasmissione dati: cavo tipo U/FTP Cat. 6, guaina rossa, per NIPRnetIT. No. Art. n.19bLM/ML3,870.00
180TELECOMM. SYSTEM: CABLE U/FTP CAT.6, purple color, for BICES
Impianto trasmissione dati: cavo tipo U/FTP Cat. 6, guaina viola, per BICESIT. No. Art. n.19cLM/ML720.00
181TELECOMMUNICATION SYSTEM: CABINET 600x1000mm, 42U
Impianto trasmissione dati: armadio 600x1000 mm, 36UIT. No. Art. n.20aEA/NO8.00
182TELECOMMUNICATION SYSTEM: TESTING AND CERTIFICATION
Impianto trasmissione dati: collaudo e certificazioneIT. No. Art. n.21aAC/LS1.00
183TELECOMMUNICATION SYSTEM: GROUNDING TEST
Impianto trasmissione dati: misura resistenza di terraIT. No. Art. n.22aAC/LS1.00
184TELECOMMUNICATION SYSTEM: ORGANIZATION AND RECONNECTION OF THE EXISTING DATA CABLES COMING FROM THE FIRST FLOOR
Impianto trasmissione dati: organizzazione e ri-collegamento dei cavi esistenti in arrivo dal piano primoIT. No. Art. n.23aAC/LS1.00
185INTRUSION DETECTION SYSTEM: RIGID METALLIC CONDUITS: Ø 25 mm
Impianto antintrusione: tubi rigidi metallici: Ø 25 mmIT. No. Art. n.24aLM/ML24.00
186INTRUSION DETECTION SYSTEM: RIGID METALLIC CONDUITS: Ø 32 mm
Impianto antintrusione: tubi rigidi metallici: Ø 32 mmIT. No. Art. n.24bLM/ML65.00

Total electrical - Totale Elettrico

TOTAL PART IV / Totale Parte IV

187 ADDENDUM # 1 ADDITIONAL LOCKS INSTALLATION IT. No. Art. n. A#1 EA/NO 4.00

A.REPAIR WORKS SUMMARY / Riepilogo Lavori di Ristrutturazione
PART I - DEMOLITIONS, EXCAVATIONS AND REMOVALS0.000.000.000.00
PART II - CIVIL, ARCHITECTURAL & STRCTURAL WORK0.000.000.000.00
PART III - MECHANICAL WORK0.000.000.000.00
PART IV - ELECTRICAL WORK0.000.000.000.00
ADDENDUM #10.000.000.00
TOTAL PRICE / Costo Totale0.000.000.000.00

OR US DOLLARS (RATE 1$ = 0,8587€) 0.00 0.00 0.00 0.00

&"Arial,Grassetto"&12FOR OFFICIAL USE ONLY

&"Arial,Grassetto"&12FOR OFFICIAL USE ONLY Sheet &P of &N

GRAND TOTAL

ASHE 20-1046 - REPAIR PAS Z-15, FAC. 7850 0.8587

INSTRUCTIONS FOR COMPLETING AF FORM 3052

TOTAL MATERIAL COSTS € 0.00 $ 0.00

TOTAL LABOR COSTS € 0.00 $ 0.00

TOTAL OTHER DIRECT COSTS € 0.00 $ 0.00

TOTAL DIRECT COSTS € 0.00 $ 0.00

OVERHEAD % € 0.00 $ 0.00

SUBTOTAL € 0.00 $ 0.00

PROFIT % € 0.00 $ 0.00

TOTAL PRICE € 0.00 $ 0.00

DATE FIRM NAME

TITLE BY

INSTRUCTIONS TO OFFERORS

&"Arial,Grassetto"&12FOR OFFICIAL USE ONLY

&"Arial,Grassetto"&12FOR OFFICIAL USE ONLY

Col 1 Item. Description of materials required, work to be done, special equipment needed, etc. Breakdown should be in sufficient detail to permit itemizing of all direct costs.

Col 2 Unit of Measure. Description of the unit in which each item is to be estimated (examples - square yards-SY, cubic yards-CY, square feet- SF, linear feet-LF, board feet-BF, each-EA,, pound-LB).

Col 3 Quantity. Contractor's estimated of quantity required in terms of unit of measure (column 2). Item and units of measure will be furnished by the Government. Quantity estimates will be furnished by the Government only when it is anticipated that a unit price contract will be issued. Otherwise, the contractor is responsible for determining quantity estimates.

Col 4 and 5 Material Costs. Enter unit cost (Col 4) of material to be supplied and total cost (Col 5) for item listed in column 1.

Col 6, 7 and 8 Labor Costs. Enter in col 6 the estimated number of manhours or mandays needed to perform the work listed in column 1. Enter in col 7 the average rate per manhour (manday) and in col 8 the total labor cost.

Col 9 Other Direct Costs. Enter estimated costs of special equipment and other items (listed in column 1), which are special to the contract and of significant dollar value.

Col 10 Line. Self-explanatory.

Note: In addition to other totals entered on various pages, the grand total of column 10, plus overhead and profit will be shown on the last page as follows:

1. The purpose of this form is to provide a standard format by which the offeror submits to the Government a summary of incurred and estimated costs, (and attached supporting information) suitable for detailed review and analysis. Prior to the award of a contract resulting from this proposal, the offeror shall, under the conditions stated in ASPR 3-807.3, be required to submit a certificate of current cost or pricing data (see ASPR 3-807.3 and 3-807.4).

2. In addition to the specific information required by this form, the offeror is experted, in good faith, to incorporate in and submit with this form any additional data, supporting schedules, or substation which are reasonably required for the conduct of an appropriate review and analysis in the light of the specific facts of this procurement. For effective negotiations, it is essential that there be a clean understanding of:

a. The existing, verifiable data.

b. The judgmental factors applied in projecting from know data to the estimate, and

c. The contingencies used by the offeror in his proposed price.

In short, the offeror's estimating process itself needs to be disclosed.

3. When attachment of supporting cost or pricing data to this form is impracticable, the data will be described (with schedules as appropriate) and made available to the contracting officer or his authorized representative upon request.

4. By submission of this proposal the offeror grants to the contracting officer, or his authorized representative, the right to examine, for the purpose of verifying the cost or pricing data submitted, those books, records, documents and other supporting data which will permit adequate evaluation of such cost or pricing data, along with the computations and projections used therein. This right may be exercised in connection with any negotiations prior to contract award.