This document is an Asbestos Survey Report for Building 5800 at Fort Bliss, Texas, conducted by ESS Environmental and Safety Solutions on November 17-18, 2022. The survey identified forty-two (42) suspect asbestos-containing homogeneous materials throughout the building, from which one hundred thirty-two (132) bulk samples were collected. The survey was performed in accordance with National Emission Standards for Hazardous Air Pollutants (NESHAP) and other federal regulations.

The laboratory analysis by Micro Analytical Services revealed that ten (10) of the forty-two materials contained asbestos, with chrysotile being the primary asbestos type detected. Materials containing asbestos included vinyl floor tiles, rubber matting, floor carpets, wall drywall, and ceiling tiles, found in various rooms and hallways. The report recommends that if planned renovation or demolition activities will disturb these asbestos-containing materials, they must be abated by a licensed/accredited contractor in compliance with federal, state, and local regulations. A mandatory 10-day notification is required prior to the start of any abatement work.

View the file

Other files

Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

�ss

ENVIRONMENTAL & SAFETY SOLUTIONS

Brown Floor Carpet with Yellow Mastic Rooms 47, 49, 50

Grey Floor Carpet Squares with Yellow Mastic Rooms 1, 2, 183

Ceramic Floor Tile Mortar Men's Latrine 139 and Women's Latrine 122

Red Rubber Matting with Yellow Mastic Room 27

12" x 12" Beige Double Vinyl Floor Tile with Rooms 146,147

Black Mastic

Brown Cove Base with Yellow Mastic Rooms 26, 47, 55

Light Grey Cove Base with Yellow Mastic Rooms 1, 2, 5

Tan Cove Base with Yellow Mastic Men's Latrine 139 and Women's Latrine 122

Finished Wall Drywall Utility 4

White Finished Wall Drywall Rooms 26, 47, 55

Tan Smooth Textured Wall Drywall Rooms 1, 2, 83

Ceramic Wall Tile Mortar Men's Latrine 139 and Women's Latrine 122

Wall Tile Mastic Men's Latrine 139 and Women's Latrine 122

2' x 4' White Pinhole Suspended Ceiling Tile Rooms 47, 49, 50

The suspect asbestos containing homogeneous materials were then assessed in terms of friability, condition, and quantity. The term "friable" means a material that when dry can be reduced to a powder using hand pressure (25 TAC§ 295.32 (45)). Prior to sampling, each suspect asbestos material was properly wetted, and then eachbulk sample was carefully extracted and placed in its own self-sealing container. Each containerwas wiped, sealed, and labeled with a unique sample number.Appropriate chain of custody paperwork was completed listing each sample collected.

Laboratory Analysis

All samples were shipped under standard chain of custody protocols to Micro Analytical

Services, Inc. (MAS) in Houston Texas. This facility is accredited by the National Voluntary

Laboratory Accreditation Program (NVLAP) for asbestos analysis, and licensed by the TDSHS as an asbestos laboratory (license number 30-0341 ).

The bulk samples were analyzed by Polarized Light Microscopy (PLM) coupled with Dispersion

Staining in accordance with EPA Method 600/M4-82-020. The laboratory report with chain of custody documentation is attached to this report.

Page 3 • Building 5800, Fort Bliss, Texas -Asbestos Survey• November 17 & 18, 2022 •