This document is a draft specifications sheet for a 101-foot articulating aerial fire truck that the Bureau of Reclamation (BOR) requires for fire protection at the Grand Coulee Power Office (GCPO) in Washington State. The apparatus must comply with NFPA standards (1901, 1902, 2016), DOT, and EPA requirements. Key specifications include a diesel turbocharged engine rated at 600 HP with 1,850 lb-ft torque, an automatic transmission with six forward gears and PTO capability, a single-stage midship-mounted fire pump delivering 2,250 GPM at 150 PSI, and a 300-gallon polypropylene water tank. The vehicle features a heavy-duty chassis with three parallel C-style rails of high-strength low alloy steel (minimum 110,000 PSI yield strength) with lifetime warranty on frame and cross members, tandem rear axles rated at 63,000 lbs, and dual HVAC systems rated for 48,000 BTU/hr heating and rapid cooling capability.
The truck must include a cab-over-engine style design with four doors and aluminum construction, comprehensive electrical systems including a 275-amp alternator and multiplex controls, LED lighting throughout (emergency warning, scene, task, and aerial lighting), an advanced 101-foot three-section articulating aerial device with 10.5-foot jib boom and self-leveling platform basket, EMS storage compartments, and complete documentation including CAD drawings, as-built wiring diagrams, operator and maintenance manuals with online access. The manufacturer must provide pre-delivery inspection at its facility, factory-trained specialist instruction at delivery (minimum three-day training at GCPO), all manuals in printed and electronic format, and comprehensive testing and certification by Underwriters Laboratories. The specifications mandate hot-dip galvanization for corrosion protection, comprehensive warranty coverage, and compliance with FMVSS, SAE, and NFPA safety standards throughout all systems and components.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
101' Articulating Aerial Fire Truck Specifications Table of Contents
1. Background & General Provisions
2. Commercial & Regulatory Compliance
3. Pre-Delivery, Delivery, and Post-Delivery Service
4. Design & Engineering Requirements
5. Warranty Requirements
6. Manuals & Documentation
7. Chassis and Structural Performance
8. Engine Performance
9. Transmission Performance
10. Axles, Suspension, Brakes, and Tires
11. Electrical System & Instrumentation
12. HVAC (Heating, Ventilation, Air Conditioning)
13. Fuel & Emissions System
14. Fire Pump & Water System
15. Cab & Crew Area
16. EMS Storage
17. Seating & Occupant Restraint
18. Visibility & Glass
19. Lighting Systems
20. Equipment Storage & Compartments
21. Aerial Platform & Performance
22. Corrosion Protection & Coatings
23. Inspection, Testing, and Acceptance
24. Training Requirements
25. Delivery Requirements
26. Salient Characteristics
1. Background & General Provisions The Bureau of Reclamation (BOR) requires a 101’ Articulating Aerial Fire Truck with a 2250 GPM pump and 300-gallon water tank for fire protection at Grand Coulee Power Office (GCPO), Washington State. The apparatus must comply with all applicable NFPA standards (including 1901, 1902, 2016), DOT, and industry best practices. All materials, technology, and procedures must be state-of-the-art and certified as required.
2. Commercial & Regulatory Compliance
· Apparatus and all components must comply with the latest NFPA, DOT, and EPA standards.
· Certification of slip resistance for all stepping, standing, and walking surfaces is required.
· Highly visible plates must state overall height, length, and GVWR.
· Manufacturer must have training and proficiency programs for certifications.
3. Pre-Delivery, Delivery, and Post-Delivery Service
· Pre-construction and pre-delivery inspections at manufacturer’s facility by Reclamation Fire Department personnel.
· All travel costs for Reclamation personnel are the responsibility of Reclamation.
· Delivery is F.O.B. to Reclamation Property Office/Fire Department Receiving, Grand Coulee, WA.
· Factory-trained specialist to provide thorough operational and maintenance instruction at delivery.
4. Design & Engineering Requirements
· Manufacturer to provide proposal blueprints (CAD), construction drawings, and technical diagrams for approval prior to construction.
· Design must ensure accessibility, safety, and compliance with best engineering practices.
· All wiring, tubing, and components must be protected and accessible for inspection and maintenance.
· USB storage with as-built wiring diagrams, manuals, and schematics included.
5. Warranty Requirements
· Standard commercial warranty for apparatus and major systems.
· All warranty details and exclusions must be provided in documentation.
6. Manuals & Documentation
· Operator, maintenance, and parts manuals (printed and electronic).
· Online service manual support with password-protected access.
· Manuals must include cross-reference part numbers, installation diagrams, digital images, and service instructions.
· Electrical schematics, warning notices, and technical publications for training included.
· Manuals must be updated automatically and accessible via web link.
7. Chassis and Structural Performance
· Heavy-duty commercial chassis designed for aerial fire apparatus service.
· Three “C” style parallel rails, high-strength low alloy steel, hot-dip galvanized.
· Minimum 110,000 PSI yield strength, RBM 3,572,000 in-lbs per rail.
· Under-frame reinforcement, seven steel plate cross members, front frame extension, rear towing provisions, roll stability control.
· Lifetime warranty on frame and cross members.
· Corrosion-resistant hardware and finish.
8. Engine Performance
· Diesel, turbocharged, 600 HP @ 1800 RPM, 1850 lb-ft torque @ 1150 RPM.
· EPA certified for 2021 emissions, cooled EGR, SCR, DEF system.
· High-pressure common rail fuel system, programmable top speed, high idle control, engine air intake with ember separator, cyclone water separator, DPF, and exhaust mitigation.
· Engine cooling system with vertically stacked charge air cooler, surge tank, radiator shields, and extended life coolant.
· Auxiliary engine brake, fan clutch, and programmable high idle.
· All engine components must meet or exceed NFPA and manufacturer requirements.
9. Transmission Performance
· Automatic transmission, electronic controls, PTO capability.
· Two 10-bolt PTO pads, internal oil filters, electronic oil level sensor, prognostic diagnostics.
· Gear ratios: 1st (3.51:1), 2nd (1.91:1), 3rd (1.43:1), 4th (1.00:1), 5th (0.74:1), 6th (0.64:1), Rev (4.80:1).
· Water-to-oil cooler, magnetic drain plug, automatic neutral, shift selector, transmission programming for fire service.
· Driveline: heavy-duty, dynamically balanced, Spicer 1810 series U-joints.
· Transmission pre-select and auxiliary brake integration.
10. Axles, Suspension, Brakes, and Tires
· Front axle (24,000 lbs), Tandem rear axle (63,000 lbs).
· Multi-leaf parabolic springs, ZF Sachs shocks, laser alignment, tire pressure indicators, balancing beads.
· Disc brakes (front), S-cam drum brakes (rear), ABS, ATC, ESC, mud/snow switch.
· Air brake system with rapid build-up, anti-compounding, spring brakes, audible alarms, air dryer, color-coded air lines.
· Rear axle differential lock, interaxle lock, and manual controls.
· Lifetime warranty on frame, 5-year warranty on axles and brakes.
11. Electrical System & Instrumentation
· 12-volt emergency vehicle architecture, Weldon V-MUX multiplex system.
· 275-amp alternator, six group 31 batteries, battery charger, shore power, and air compressor.
· Load management, diagnostics, data recording, seat belt warning, multiplex displays (Vista IV), accessory power distribution, communication antenna, and intercom system.
· All wiring to be color, function, and number coded, routed for accessibility, and protected by looms and grommets.
· LED lighting for ground, step, compartment, and scene illumination.
· Compliance with SAE, NFPA, and FMVSS standards.
12. HVAC (Heating, Ventilation, Air Conditioning)
· Dual system with defroster, cab and crew heater, and air conditioner.
· Emergency vehicle grade, rated for 48,000 BTU/hr heating, 30,000 BTU defrost, and rapid cooling.
· Controls via Vista screens, aluminum condenser cover, premium silicone hoses, gravity condensation drain.
· All systems must meet or exceed SAE and NFPA standards.
13. Fuel & Emissions System
· 68-gallon fuel capacity, DEF tank (5+ gallons), cross-flow air-to-fuel cooler, fuel filter/water separator, secondary filter.
· DEF tank with coolant lines for freeze protection, access panel, and warning indicators.
· All components must support emissions compliance and diagnostics.
14. Fire Pump & Water System
· Single-stage, midship-mounted, 2250 GPM @ 150 PSI, 300-gallon polypropylene tank.
· Stainless steel plumbing, hydrostatically tested, certified to NFPA 1901.
· Automatic priming, pressure governor, master drain, low point drains, intake/dump valves, foam system (Fee-Con APH 1.5, 1400 GPM), external foam supply, and all required controls.
· Water tank with lifetime warranty, fill tower, overflow, and certified capacity.
· All controls, gauges, and labels per NFPA standards.
15. Cab & Crew Area
· Custom, cab-over-engine style, fully enclosed, four doors, flat roof, high-strength aluminum construction.
· Four-point rubber isolated mounting, tilt system, insulation, and sound damping.
· Ergonomic dash, modular console, sun visors, grab handles, and advanced safety features (roof crush, side impact, frontal impact tests).
· All doors with full-length coverage, heavy-duty handles, locks, and weather seals.
· Interior finished in marine-grade vinyl, polyurethane coating, and acoustic matting.
· All cab features must meet or exceed FMVSS, SAE, and NFPA standards.
16. EMS Storage
· Dedicated driver and officer side EMS compartments, minimum 9.8 and 7.5 cubic feet, respectively.
· Hinged exterior doors, interior access, adjustable shelves, DA sanded finish, LED lighting, and secure locking.
· Compartments must be weather-resistant and illuminated.
17. Seating & Occupant Restraint
· Seating for government staffing, 911 Seats XL series, gray with red seat belts, 3pt ABTS, headrests, and SCBA brackets.
· Storage under driver and officer seats, forward-facing center seats, enclosed seat boxes, and parade panels.
· All seats and materials must meet FMVSS, NFPA, and flammability standards.
· Occupant restraints and monitoring systems included.
18. Visibility & Glass
· One-piece safety glass windshield, power windows, heated/motorized mirrors, wipers, and washer system.
· All glass and accessories must meet FMVSS and SAE requirements.
· Visibility enhancement systems (cameras, sensors) included.
19. Lighting Systems
· Emergency warning, scene, task, compartment, interior, and aerial lighting (LED).
· Lightbars, marker lights, turn signals, backup lights, scene lights, tip lights, and platform lighting.
· All lighting must be NFPA, DOT, and SAE compliant.
· Multiplexed control and diagnostics for all lighting systems.
20. Equipment Storage & Compartments
· Weather-resistant compartments, roll-up AMDOR or equal doors, adjustable shelving, pull-out trays, and compartment lighting.
· Compartment floors and walls coated with Line-X or equal, removable vinyl matting, and drip pans.
· Ladder and pike pole storage, access ladders, and SCBA cylinder compartments.
· All compartments must be labeled, illuminated, and compliant with NFPA standards.
21. Aerial Platform & Performance
· 101-foot articulating aerial device, three-section, steel, hot-dip galvanized, with 10.5' jib boom.
· Platform basket with self-leveling, heat shield, water curtain, safety harness points, rope eyelets, repelling arms, parapet arms, and storage boxes.
· Hydraulic system with load-sensing pump, emergency backup, and proportional controls.
· Smart screens at control stations, joystick controllers, load and reach charts, leveling gauges, and collision protection.
· Breathing air system, electrical outlets, thermal imaging camera, and LED rung lighting.
· All aerial and platform features must meet or exceed NFPA, SAE, and industry standards.
22. Corrosion Protection & Coatings
· Hot-dip galvanized frame, subframe, torque box, outriggers, aerial sections, and platform structure.
· Line-X or equal coating on specified surfaces, aluminum and stainless steel fasteners, and compartment interiors.
· Corrosion protection warranties as specified.
23. Inspection, Testing, and Acceptance
· Road, pump, water system, aerial, and electrical testing required.
· Underwriters Laboratories certification for pump and aerial.
· All testing must be documented and provided at delivery.
· Acceptance contingent on successful completion of all tests.
24. Training Requirements
· Operator and maintenance training provided by manufacturer.
· Training materials and reference documentation included.
· Minimum three-day instruction period at Grand Coulee Power Office, WA.
· All costs for instruction borne by bidder.
25. Delivery Requirements
· Deliver fully assembled, tested, documented, and operational.
· Conduct delivery demonstration and provide final documentation.
· Paint, graphics, and labeling per customer specifications.
· Touch-up paint and custom door seals included.
26. Salient Characteristics
· 101-foot articulating aerial device
· 2,250 GPM pump, 300-gallon tank, 600 HP engine
· ABS, stability control, HVAC, communications integration
· Commercial warranty support
· All features and systems as detailed above