Appendix C - Service Call Historical Workload Data.xlsx

XLSX spreadsheet 451 KB Posted

Attached to
Charleston Air Base Dormitory Maintenance Federal contract opportunity
Solicitation number
FA4418ABDORMMX
Issued by
Department of the Air Force Air Mobility Command

View the file

Other files for this federal contract opportunity

Other files attached to Charleston Air Base Dormitory Maintenance, newest first.
File Type Posted
Market Research Questionaire - AB Dorms.xlsx XLSX spreadsheet
PWS - Air Base Dormitory.docx DOCX document
Appendix B - Facilities And Structures.xlsx XLSX spreadsheet
Appendix A - Real Property Installed Equipment Inventory.xlsx XLSX spreadsheet

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

WO Totals

Service Call Historical Workload Data - (2017 - Present)
BuildingDescriptionWork OrdersEmergencyUrgentRoutine
460Dormitory110235295772
461Dormitory81932234553
464Dormitory52714167346
466Dormitory64320221402
468Dining Facility2933076187
469Water Plant302719
473Dormitory58920193376
479Dormitory82832216580
TOTALS:483118514093235

Work Tasks

WT-IDFacilityTask NameMaintenance Resolution DescriptionTask PriorityStatusResp Org
24021904603B - 460 - WT - Electrical - Ballard Lights Inop - Repair - Mr Drennan - 05/16/173B - Medium SustainClosedJB CHARLESTON - ELECTRICAL SYSTEMS
32208654643B - 464 - WT - HVAC - Prepare Boiler For Winter Season - Repair - Sgt Green - 11/20/2017Checked all safeties and ops tested boiler3B - Medium SustainClosedJB CHARLESTON - HVAC SHOP
40447474793A - 479 - WT - Electric - Repair Emergency Lights Inop - Repair - Daniel Pearson - 5/2/2018 - SR 1346164Replaced, repaired all emergency lights for building. Drennan.3A - High SustainClosedJB CHARLESTON - ELECTRICAL SYSTEMS
40532264643A - 464 - WT - Utilities - 3rd FL RM 320 Fire Suppression Leak - Repair - SSgt Kagan - 05/03/183A - High SustainClosedJB CHARLESTON - WATER AND FUELS SYSTEM MX
47896244733B - 473 - WT - HVAC - Inspect Boiler - Repair - Sgt Green - 09/20/2018Prepped boiler for inspection. Opened boiler, checked tubes and safeties. Test ran boiler to ensure no leaks, electrical issues3B - Medium SustainClosedJB CHARLESTON - HVAC SHOP
50807744663A - 466 - WT - HVAC - Reset Hot Water Heater for BLDG - Repair - D. Pearson - 11/08/18 - SR 1520182Reset boiler3A - High SustainClosedJB CHARLESTON - HVAC SHOP
24444314603A - 460 RM 108 - WT - Utilities - Flooding in the dorm rooms - Repair - SSgt Scott - 05/22/173A - High SustainClosedJB CHARLESTON - WATER AND FUELS SYSTEM MX
30174324643A - 464 - HVAC - Inv/Rpr HVAC for 3d floor Odd rooms - Repair - TSgt Brown - 10/10/173A - High SustainClosedJB CHARLESTON - HVAC SHOP
49973234793A - 479 - WT - HVAC - RMS 130, 135 & 309 A/C INOP - Repair - SSgt Herron - 10/29/18Chiller is currently running but has bad sensor and condenser motor. Wired chiller to run with circuit until parts come in

Replaced Condenser motor and sensor

3A - High SustainClosedJB CHARLESTON - HVAC SHOP
53639414643A - 464 - WT - Utilities - Repair Broken Sprinkler Head Rm 203 - Sgt Corban - 01/24/2019Replaced broken sprinkler head3A - High SustainClosedJB CHARLESTON - WATER AND FUELS SYSTEM MX
59090804613B - 461 - WT - Utilities - Lower Riser Leaking Water From The Bottom Causing An Alarm - Repair - TSgt Vandenhaak - 05/14/19Tightened packing in valve3B - Medium SustainClosedJB CHARLESTON - WATER AND FUELS SYSTEM MX
78752394603B - 460 - WT - HVAC - Rm 329 Thermostat In-Op - Repair - Miranda Watson - 06/10/20 - SR 2087804troubleshot damper motor. replaced motor. damper now open. fully operational. AMB 6/12/203B - Medium SustainClosedJB CHARLESTON - HVAC SHOP
84896464613B - 461 - WT - HVAC - Rm 303D Too Warm - Repair - Levi Shanks - 09/28/20 - SR 2212101Troubleshot fan coil unit, clean pitot tube and adjusted damper to 100% (29 Sept 20) ETGS3B - Medium SustainClosedJB CHARLESTON - HVAC SHOP
107891034613B - 461 - WT - Elec - 303B Repair Light Switch that Controls the Main Lights - Repair - T. Parks - 11/19/21 - SR26962099 Dec 21-tripped breaker/replaced light switch3B - Medium SustainClosedJB CHARLESTON - ELECTRICAL SYSTEMS
99909724793B - 479 - WT - Electric - Inv/ Repair Emergency Lights in Below Rooms - Repair - M. Watson - 5/18/21 - SR24575003June21 - Replaced stair well lights
finished rplc'ing lights3B - Medium SustainClosedJB CHARLESTON - ELECTRICAL SYSTEMS
113562254663A - 466 - WT - Electric - emergency lights not operational outside of Multiple Rooms - RPR - L. Teague - 5/12/22 - SR 292260016 May - Replaced 8 LED emergency lights (Material on hand)3B - Medium SustainClosedJB CHARLESTON - ELECTRICAL SYSTEMS
117315704603B - 460 - WT - Electric - RM 123 Electrical Outlets Out - Repair - Humble - 8/11/22 - SR 307314215 Aug 22. Investigated cause of lost of power. Checked breaker panel, but all breaker were working properly. Started to open outlet boxes and found burned marks on the back of a GFCI outlet. Replaced GFCI outlet and test all other outlets in the circuit. All outlets operational. Clark3B - Medium SustainClosedJB CHARLESTON - ELECTRICAL SYSTEMS
118204984613B - 461 - WT - Electric - RM 303 Water In Circuit Breaker - Repair - SSgt Bainter - 08/31/2207Sep22 - troubleshot electrical panel. Water was condensation. The fix is to utilize a dehumidifier.3B - Medium SustainClosedJB CHARLESTON - ELECTRICAL SYSTEMS
119136984793B - 479 - WT - Electric - RM 115 Kitchen Exhaust Vent Has No Power - Repair - Mr Martin - 09/19/22troubleshot exhaust fan3B - Medium SustainClosedJB CHARLESTON - ELECTRICAL SYSTEMS
120738084613B - 461 - WT - Electrical - Kitchen Lights Switch in the Room 306 - RPR - J,. Humble - 10/28/22 - SR31976131 Nov 22. Replaced single pole switch. Clark
Used parts from interior shed.3B - Medium SustainClosedJB CHARLESTON - ELECTRICAL SYSTEMS
120925444733B - 473 - WT - Electric - Ceiling Fan/Light Switches in Room 326 - RPR - K. Switzer - 11/1/22 - SR320548815 Nov 22. Troubleshoot and repair light/fan power. Clark3B - Medium SustainClosedJB CHARLESTON - ELECTRICAL SYSTEMS
121442784793B - 479 - WT - Electric - Closet Lights INOP and cannot be removed in Room 331 - RPR - B. Bainter - 11/16/22 - SR322833122 Nov 22. Replaced lights with LEDs. Clark/Wang
Used parts from the interior shed.3B - Medium SustainClosedJB CHARLESTON - ELECTRICAL SYSTEMS
121931604793B - 479 - WT - ELECTRIC - RM 222 Heat lamp switch dial needs to be repaired - Repair - Switzer - 11/28/22 - SR 324619412 Dec 22. Troubleshot switch found bad wires and switch replaced wires, switch and bulbs. Clark/Guillermo.3B - Medium SustainClosedJB CHARLESTON - ELECTRICAL SYSTEMS
84929984683B - 468 - WT - Electric - Inv Power Issue With Heating Coal In Freezer Unit - Repair - Christopher Balter - 09/29/20 - SR 22132611Oct20 - Planning work requirements
6Oct20 - Ran new circuit for heating coil.3B - Medium SustainClosedJB CHARLESTON - ELECTRICAL SYSTEMS
32486154613B - 461 - WT - Electric - Rpr Exterior lights - Repair - Daniel Pearson - 11/30/17 - SR 12433433B - Medium SustainClosedJB CHARLESTON - ELECTRICAL SYSTEMS
40447394613A - 461 - WT - Electric - Inv/Rpr/Rpl Emergency Lighting Throughout Facility - Repair - C. Scott - 05/02/18 - SR 1346156Lights checked on 18 June 18, all working as intended. Drennan.3A - High SustainClosedJB CHARLESTON - ELECTRICAL SYSTEMS
40447674643A - 464 - WT - Electric - Inv/Rpr/RPL Emergency Lights Throughout Bldg - Repair - C. Scott - 05/02/18 - SR 1346185All emergency lights have been repaired or replaced 5 June 18 Drennan.3A - High SustainClosedJB CHARLESTON - ELECTRICAL SYSTEMS
41463434603B - 460 - WT - Utilities - Repair Backflow - Repair - TSgt Corban - 5/22/2018repair backflow3B - Medium SustainClosedJB CHARLESTON - WATER AND FUELS SYSTEM MX
42922884643B - 464 - WT - HVAC - 3rd Floor HVAC System Leaking - Repair - Sgt Scott- 06/15/2018repaired drain line3B - Medium SustainClosedJB CHARLESTON - HVAC SHOP
43781344603B - 460 - WT - Utilities - Assist Structures With Shower Floor RM 121 - Repair - C. Herron - 06/28/2018moved shower drain and mixing valve3B - Medium SustainClosedJB CHARLESTON - WATER AND FUELS SYSTEM MX
46750454663B - 466 - WT - HVAC - Restore A/C to Rm 117 - Repair - Daniel Pearson - 9/4/2018 - SR 1456802Cleaned drain line3B - Medium SustainClosedJB CHARLESTON - HVAC SHOP
20634844663A - 466 - WT - Utilities - (C0300) Clogged sink - Repair - MSgt Woodcock - 03/06/173A - High SustainClosedJB CHARLESTON - WATER AND FUELS SYSTEM MX
22964144603B - 460 - WT - Utilities - D009 Shower not draining - Repair - Sgt Scott - 03/07/173B - Medium SustainClosedJB CHARLESTON - WATER AND FUELS SYSTEM MX
22964554663B - 466 - WT - Utilities - D010 Low Water Pressure in Shower - Repair - Sgt Scott - 03/07/173B - Medium SustainClosedJB CHARLESTON - WATER AND FUELS SYSTEM MX
23942984613A - 461 - WT - Utilities - Repair Broken Toilet Flapper Rm 308A - Repair - SSgt Scott - 5/15/2017 - SR 11255303A - High SustainClosedJB CHARLESTON - WATER AND FUELS SYSTEM MX
23950874603A - 460 - WT - Utilities - Repair Toilet in Rm 234 - Repair - SSgt Scott - 5/15/2017 - SR 11256003A - High SustainClosedJB CHARLESTON - WATER AND FUELS SYSTEM MX
24020964733B - 473 - WT - Electric - Ballard Lights Inop - Repair - Mr Drennan - 05/16/173B - Medium SustainClosedJB CHARLESTON - ELECTRICAL SYSTEMS
24170914613C - 461 - WT - Utilities - D035 RPL Toilet Fill Valve - Repair - TSgt Pearson - 03/14/173C - Low SustainClosedJB CHARLESTON - WATER AND FUELS SYSTEM MX
24979274733C - 473 - WT - Structures - Rpr wall and base boards in 1st fl laundry room - Repair - D. Pearson - 06/06/17 - SR 11368223C - Low SustainClosedJB CHARLESTON - STRUCTURE SHOP
25396604613C - 461 - WT - HVAC - Inv/Rpr HVAC for Bldg 461, Room 312D - Repair - D. Pearson - 06/15/17 - SR 1142949Replaced AHU bearings and motor.3C - Low SustainClosedJB CHARLESTON - HVAC SHOP
26010974643A - 464 - WT - HVAC - Inv/Rpr HVAC for whole Bldg - Repair - Sgt Scott - 07/05/17 - SR 11532023A - High SustainClosedJB CHARLESTON - HVAC SHOP
29107904793B - 479 - WT - Electric - Repair / Replace Lights - Repair - Mr. Bashara - 09/18/173B - Medium SustainClosedJB CHARLESTON - ELECTRICAL SYSTEMS
29154244643B - 464 - WT - Electric - Rpl light for outside hallways - Repair - D. Pearson - 09/19/17 - SR 12007113B - Medium SustainClosedJB CHARLESTON - ELECTRICAL SYSTEMS
43270474603C - 460 - WT - Structures(Joy) - RPR Cracked Shower Floor for Room 121 - Repair - C. Herron - 06/21/18 - SR 1392113Inspected shower. C/O

- 19 OCT 2018 - Plumbing shop will order, SSgt Young is to coordinate to ensure it is correct item.

- 31 OCT 2018 - POST POST submitted

- 1 Feb 2019 - removed old shower

- 5 Mar 2019 - Searched multiple vendors for replacement

- 6 Mar 2019 - located and picked up parts from multiple locations

- 12 Mar 2019 - Moved drain/framed for shower

- 13 Mar 2019 - continued framing shower walls

- 20 Mar 2019 - exchanged damaged pan

- 9 May 2019 - increased concrete hole size

- 6 June 2019 - installed one wall

- 12 June 2019 - fit shower basen

- 24 June 2019 - poured concrete

- Put up drywall and mudded 06/25/2019 C/O

- 27 June 2019 - Framed wall spacers/finished concrete C/O

- 1 July 2019 - grouted

- 8 July 2019 - worked drywall 07/30/2019 Water leaking from upper room causing damage/hault to work production. Once repaired the shower install will be completed.

1 Oct 19 - COmpleted shower replacement.3C - Low SustainClosedJB CHARLESTON - STRUCTURE SHOP
55964154603B - 460 - WT - Utilities - Vanity Sink Clogged in Rm 206 - Repair - Levi Shanks - 03/19/19 - SR 1619683Went in through wall and snaked drain Also, replaced P-Trap.3B - Medium SustainClosedJB CHARLESTON - WATER AND FUELS SYSTEM MX
57746244663B - 466 - WT - Electric - Emergency Lights Not Operational (See Description For Locations) - Repair - Christina Herron - 04/17/19 - SR 16499777 Aug 2019 - Rplc'd Emer lights3B - Medium SustainClosedJB CHARLESTON - ELECTRICAL SYSTEMS
59067064793A - 479 - WT - Utilities - Inv/Rpr Sprinkler Activation Rm 301/303 - Repair - Sgt Vanden Haak - 05/14/19Microwave caught fire, popped head, replaced head, reset fire system.3A - High SustainClosedJB CHARLESTON - WATER AND FUELS SYSTEM MX
60816974603B - 460 - WT - HVAC - Suite Rms 317 & 319 A/C Not Working Properly - Repair - Levi Shanks - 06/24/19 - SR1721221Room temp is currently 84 degrees with a discharge temp of 75. Filters and belts on order for AHUs throughout facility (20 August 19)3B - Medium SustainClosedJB CHARLESTON - HVAC SHOP
61192024793A - 479 - WT - Utilities - Rm 306 P-Trap Broken, Leaking Water - Repair - Levi Shanks - 07/01/19 - SR 1729698Replaced p trap and snaked sink3A - High SustainClosedJB CHARLESTON - WATER AND FUELS SYSTEM MX
71011414793B - 479 - WT - Electric - Rm 310 Ceiling Fan Lights In-Op - Repair - Levi Shanks - 01/03/20 - SR 193646310Jan20-Fan is bad. FM ordering new one.
29Jan20- Customer is ordering new fan. Work Task CLOSED and customer must submit new WT when fan is received.3B - Medium SustainClosedJB CHARLESTON - ELECTRICAL SYSTEMS
71648274793B - 479 - WT - HVAC - Bldg 479 HVAC In-Op - Repair - Levi Shanks - 01/13/20 - SR 1948271Discovered inop AHU. Motor kept blowing fuses. Trouble shot system and found wires shorted to wire conduit. Removed conduit and rewired AHU Motor (14 Jan 20) ETGS3B - Medium SustainClosedJB CHARLESTON - HVAC SHOP
75500474793B - 479 - WT - Utilities - Rm 323 Vanity Sink Clogged - Repair - M Watson - 03/20/20 - 2025734Snaked through vent3B - Medium SustainClosedJB CHARLESTON - WATER AND FUELS SYSTEM MX
79399084613B - 461 - WT - HVAC - Air Handler Motor In Rm 209D Making Loud Noise - Repair - Levi Shanks - 06/24/20 - SR 2104112Pm'd sys.
AMB 6/26/203B - Medium SustainClosedJB CHARLESTON - HVAC SHOP
80502984733A - 473 - WT - HVAC - No Hot Water In Facility - Repair - SSgt Shanks - 07/10/20 - SR 2120417Frequency drive has blown fuse. No fuse available locally, had to overnight. Working with control shop for temporary solution (10 July 20) ETGS
Replacement VFD picked up and placed in mech room. JPB 10/12/20213A - High SustainClosedJB CHARLESTON - HVAC SHOP
81496154613A - 461 - WT - HVAC - AC Inop - Repair - Mrs. Watson - 07/28/2020 - SR 2141195Replaced inlet/outlet water temp sensor. Monitoring chiller. AMB 7/29/20
Replaced fuses and coupling. AMB 8/7/203A - High SustainClosedJB CHARLESTON - HVAC SHOP
83069324793B - 479 - WT - Structures - Inv/ Repair leakaage From AHU#3 Above Room 3 Causing Water Damage - Repair - L. Shanks - 8/26/20 - SR217423515 Sept 2020 - replaced drywall

21 Sept 2020 - applied mud 22 Sept 2020 - applied 2nd coat

- 24 Sept 2020 - sanded wall3B - Medium SustainClosedJB CHARLESTON - STRUCTURE SHOP
83113164793B - 479 - WT - HVAC - Rpr Chill Water Pipe - Repair - Lee Martin - 08/26/20Repiped AHU. Ordering sensors for chiller. AMB 8/26/20
Leak handled. JPB 2/18/20213B - Medium SustainClosedJB CHARLESTON - HVAC SHOP
83522554793B - 479 - WT - Structures - Rpr 2 Holes In Wall - Repair - Tamaya Parks - 09/03/20 - SR 21858068 Sept 2020 - repaired and patched holes3B - Medium SustainClosedJB CHARLESTON - STRUCTURE SHOP
85797794663B - 466 - WT - Electric - Rpr Fan Light In Rm 212 - Repair - Tamaya Parks - 10/09/20 - SR 222884222oct20 - Rewired and replaced fan.3B - Medium SustainClosedJB CHARLESTON - ELECTRICAL SYSTEMS
88465364793A - 479 - WT - HVAC - Inv Chiller Shutdown/Reset Chiller - Repair - Levi Shanks - 11/10/20 - SR 2262122Chiller running at 50%. One circuit locked out on Electronic TXV failure. AMB 11/12/203A - High SustainClosedJB CHARLESTON - HVAC SHOP
106648994643A - 464 - WT - HVAC - Tech School Dayroom Flooded With Water - Repair - SSgt Brannan - 10/08/21 - SR 2648882Cleaned out drain line in 2 AHUs. JPB 10/8/20213A - High SustainClosedJB CHARLESTON - HVAC SHOP
108223284663B - 466 - WT - Electric - Fan Light In-Op In Rm 305 - Repair - Miranda Watson - 12/07/21 - SR 27129469dec21-replaced light socket3B - Medium SustainClosedJB CHARLESTON - ELECTRICAL SYSTEMS
99907374663B - 466 - WT - Electric - Inv/ Repair Emergency lights not operations All 1st floor - Repair - M. Watson - 5/18/21 - SR2457465- rplc'd emerg light throughout building3B - Medium SustainClosedJB CHARLESTON - ELECTRICAL SYSTEMS
113838154733B - 473 - WT - Structures - (Hall) Broken Glass Window By Entrance Door Room 202 - Repair - J. Humble - 05/19/22 - SR 29346448/18/2022 - Paperwork turned in window repaired

8/5/2022 - Payed and received receipt/waiting to process paperwork.

6/29/2022 - called to place, repair ordered/worked paperwork 6/28/2022 - Placed order for materials.

6/23/2022 - follow-up on quote.3B - Medium SustainClosedJB CHARLESTON - STRUCTURE SHOP
118182974793B - 479 - WT - Electric - RM 117 Heat Lamp Outlet In Bathroom Not Working - Repair - B. Bainter - 09/01/22 - SR 311189614 Sept 22. Replaced timer switch for bathroom heat lamp. Requester would need to replace bulb. Rogers/Guillermo.3B - Medium SustainClosedJB CHARLESTON - ELECTRICAL SYSTEMS
121417384793B - 479 - WT - Electric - Closet Light Rm 234 INOP - Repair - Bainter - 11/15/22 - SR 322692228 Nov 22. Replace fixture. Clark/Wang
Used parts from interior storage shed3B - Medium SustainClosedJB CHARLESTON - ELECTRICAL SYSTEMS
122117494643B - 464 - WT - ELECTRIC - Common area has a broken ballast - Repair - Felder - 11/30/22 - SR 325156122 Dec 22. Replaced bulbs. Rogers.3B - Medium SustainClosedJB CHARLESTON - ELECTRICAL SYSTEMS
100910464683A - 468 - WT - HVAC - Inv/ Repair AC Unit in the Kitchen Area/Extremely Hot - Repair - C. Balter - 6/7/21 - SR2483877Belts & filters changed. Still diagnosing issues. JPB 6/7/2021

Cleaned coils. Still working. JPB 6/8/2021

Opened dampers. JPB 6/10/20213A - High SustainClosedJB CHARLESTON - HVAC SHOP
108721874683A - 468 - WT - HVAC - Inv/ Repair the entire facility has been cold for about 2 weeks - Repair - C. Howard - 12/28/21 - SR2731079Make-up water line was shut; opened & filled hot water system. Good to go. JPB 12/28/20213A - High SustainClosedJB CHARLESTON - HVAC SHOP
109741734683B - 468 - WT - HVAC - Dining Area Is Cold - Repair - Rondashia Singleton - 2/3/2022 - SR 2775327Reference WT# 110021723B - Medium SustainClosedJB CHARLESTON - HVAC SHOP
62762044683B - 468 - WT - Utilities - Female Sink Clogged - Repair - SrA Lewis - 08/05/19snaked Sink3B - Medium SustainClosedJB CHARLESTON - WATER AND FUELS SYSTEM MX
74993734683A - 468 - WT - Utilities - Kitchen Drain is Clogged - Repair - SSgt Morrison - 03/11/20 - SR 2017201Snaked Drains3A - High SustainClosedJB CHARLESTON - WATER AND FUELS SYSTEM MX
95777154683B - 468 - WT - Utilities - Replace 3 Sprinkler Head Escutcheon Plates - Christopher Balter - 03/23/21 - SR 2391797Escutcheon plates replaced3B - Medium SustainClosedJB CHARLESTON - WATER AND FUELS SYSTEM MX
21262074693B - 469 - WT - HVAC - Repair chiller - Repair - SSgt Barr - 04/10/173B - Medium SustainClosedJB CHARLESTON - HVAC SHOP
21801124693B - 469 - WT - Electric - Install 80 ton chiller - Repair - TSgt Green - 04/18/173B - Medium SustainClosedJB CHARLESTON - ELECTRICAL SYSTEMS
94903444693B - 469 - WT - HVAC - Check cooling tower fan motor - Repair - Lee Martin - 3/4/2021SSgt Hays/SrA Little 10Mar2021, removed ceased fan blades.

Waiting for parts; consulting on how to remove taper locks. JPB 3/15/2021 One fan removed, working on second fan. JPB 3/24/2021 Chiller #2, pulled oiled and monitored pressure. Pressure was 32psi and current is 25psi. Sight glass still full. CAM 4/6/2021 Ordered Cooling Tower Motors (16 June 21) ETGS Putting motors in cooling tower. JPB 6/29/2021 All motors are up. Need to wire and attach fan blades. JPB 7/1/2021 Wired all motors. Started attaching fan blades. JPB 7/6/2021 2/4 motors running. Need fan blades to complete job. On order. JPB 7/8/2021 Installed both motors. Need to wire up & shim one in place. JPB 8/31/2021

Wired up both motors & aligned second motor. JPB 9/23/20213B - Medium SustainClosedJB CHARLESTON - HVAC SHOP
41392944603B - 460 - WT - HVAC - Repair A/C in Rm 225 & 225 Too Hot - Repair - Daniel Pearson - 5/22/2018 - SR 1363950VFD was tripping on overcurrent alarm. Checked wiring and restarted VFD. AHU back up and running3B - Medium SustainClosedJB CHARLESTON - HVAC SHOP
41836764603A - 460 - WT - HVAC - INV/RPR HVAC Building- Repair - C. Herron - 05/29/18 - SR 1369119AHU had grounded motor and bad freq drive. Replaced both. System 100% operational3A - High SustainClosedJB CHARLESTON - HVAC SHOP
42259634603A - 460 - WT - Utilities - Unclog Vanity Sink in Rm 207 - Repair - Christopher Scott - 6/7/2018 - SR 1377714unclog drain3A - High SustainClosedJB CHARLESTON - WATER AND FUELS SYSTEM MX
48178224793A - 479 - WT - Utilities - No Hot Water Replace Pump - Repair - CSN Montilba - 09/26/18researched and installed new pump3A - High SustainClosedJB CHARLESTON - WATER AND FUELS SYSTEM MX
49377244793B - 479 - WT - Electric - RPR/RPL Lights on BLDG, See Attached Sheet - Repair - C. Herron - 10/16/18 - SR 1498304Changed ballasts, left requestor with bulbs to order. Let them know we're closing job and open a new work order upon them receiving bulbs 18 Oct Drennan.3B - Medium SustainClosedJB CHARLESTON - ELECTRICAL SYSTEMS
49478314603A - 460 - WT - HVAC - INV/RPR HVAC for Room 326/328 - Repair - D. Pearson - 10/18/18 - SR 1500944Cleaned Pito Tube and adjusted damper3A - High SustainClosedJB CHARLESTON - HVAC SHOP
49973234793A - 479 - WT - HVAC - RMS 130, 135 & 309 A/C INOP - Repair - SSgt Herron - 10/29/18Chiller is currently running but has bad sensor and condenser motor. Wired chiller to run with circuit until parts come in

Replaced Condenser motor and sensor

3A - High SustainClosedJB CHARLESTON - HVAC SHOP
59982524663B - 466 - WT - Lock Shop - Rm 129 4 Replacement Keys (Signed 332 In Notes & Documents) - Repair - Levi Shanks - 06/06/19 - SR 1702121- 6 June 2019 - cut keys3B - Medium SustainClosedJB CHARLESTON - STRUCTURE SHOP
62030544603B - 460 - WT - Structures (White) - Assess Damaged Drywall In Closet - Repair - Levi Shanks - 07/18/19 - SR 1749888- 08/22/2019 - Leak from HVAC unit drip pan. Coming up with fix once HVAC gets unit running again to track exact leak location.

-10/30/2019-Gathered materials to kilz over surfuce. C/O -10/31/2019-Found new HVAC leak. Contacted HVAC to form plan. C/O -11/12/2019-Talked with dorm manager & HVAC. Shut down HVAC system to conduct repairs to secondary pan. C/O -11/14/2019- Cleaned rust out of the drip pan, prepping for repair. C/O -11/25/2019-Building new pan system.C/O -12/02/19 - Pop riveted 3 patches/hydro stopped another 1/4 of pan.

12/03/19 - Hydro stopped pan/need to cut/seal drain C/O 12/10/19 - Kilz mold above ceiling C/O 12/11/19 - peeled paint/skim coated with mud began repairing C/O 12/12/19 - Skim coated, water damage from drip pan needs sanded/cleaned C/O 12/13/19 - sanded wall/cleaned areasprayed mold killer C/O 12/16/19 - removed shelf/Kilz over mold/mudded over mold that was sprayed last week C/O

01/07/2020-Referred to paint contractor. Complete3B - Medium SustainClosedJB CHARLESTON - STRUCTURE SHOP
63097054603B - 460 - WT - Electric - North And Center Stairwells Of Bldg 460 Lights Are Out - Repair - Levi Shanks - 08/12/19 - SR 178122616Aug19 - The lights referenced have emergency ballasts. We cannot direct wire these fixtures without hybrid bulbs. We are forced to replace the ballasts. At the COB, we are still replacing ballasts. Will have to pick it back up on Monday, 19Aug19.

6apr20-2 lights remaining to be repaired.

8apr20-all lights repaired.3B - Medium SustainClosedJB CHARLESTON - ELECTRICAL SYSTEMS
79220984731 - 473 - WT - HVAC - (S/B) No Hot Water - Repair - Dorm MGMT - 06/21/20Replaced fuse on VFD for boiler. AMB 6/24/201-EmergencyClosedJB CHARLESTON - HVAC SHOP
83964334793B - 479 - WT - Structures - Rm 212 Rpl Shelf bottom vanity sink - Repair - L Shanks - 2193282 - 09/11/2014 Sept 2020 - repairing drywall

17 Sept 2020 - patched and 1st coat 18 Sept 2020 - finished drywall repair 05 Oct 2020 - removed old shelf cut and added laminate to new one, install tomorrow

06 Oct 2020 - removed bottom and shelf from cabinet/cut formica and replaced3B - Medium SustainClosedJB CHARLESTON - STRUCTURE SHOP
86370194663B - 466 - WT - HVAC - Rm 328 Too Cold - Repair - Levi Shanks - 10/19/20 - SR 2235697Dialed back damper in VAV. AMB 10/23/203B - Medium SustainClosedJB CHARLESTON - HVAC SHOP
90126514793A - 479 - WT - HVAC - Repair Heat - Repair - MSgt Hart - 12/03/2020Found fittings; need to install pump. JPB 12/9/2020
Pump installed. Heating HW boiler operational. JPB 12/10/20203A - High SustainClosedJB CHARLESTON - HVAC SHOP
91012004603A - 460 - WT - HVAC - RM 330/332 Temp 87 Degrees - Repair - Levi Shanks - 12/14/2020 - SR 2292938One rm was normal operation, another was stuck on heat; reset and monitored f/ 15 mins. JPB 12/15/20203A - High SustainClosedJB CHARLESTON - HVAC SHOP
100912154793B- 479 - WT - Structures - Inv/ Repair Re secure Shower Door Frame & Guide Basket - Repair - L. Shanks - 6/7/21 - SR24839426/25/2021 - secured shower and door frame3B - Medium SustainClosedJB CHARLESTON - STRUCTURE SHOP
102607334603B - 460 - WT - HVAC - Rm 114 Too Hot - Repair - Tamaya Parks - 07/20/21 - SR 2543194Ordered actuator (21 July 21) ETGS

2 bad condenser fan motors/have to order. JPB 7/23/2021

All parts picked up. Temps shooting 56°; all good. JPB 1/30/20233B - Medium SustainClosedJB CHARLESTON - HVAC SHOP
102891304603B - 460 - WT - HVAC - Inv/Repair Airflow Barely Flowing Room 127 - Repair - T. Parks - 07/27/21 - SR 2553437Most likely a bad 3-way valve; also has plugged coils. JPB 7/27/2021

Pressure washed cooling & heating coils' exposed faces. No noticeable change in CFM. Motor/pulley on order.

Replaced VFD condenser fans on chiller; still having issues. JPB 7/29/2021 PM'd chiller; ID'd burnt VFD boards. Ordering replacements. JPB 7/30/2021

Verified space temps with Tracer. JPB 3/23/20223B - Medium SustainClosedJB CHARLESTON - HVAC SHOP
90752224793B - 479 - WT - HVAC - Room 112 Too Warm - Repair - Mrs. Parks - 12/09/2020 - SR 2288884Damper opened, possibly complete, need to verify tomorrow. JPB 2/18/2021
Verified room temp/airflow; good to go. JPB 2/19/20213B - Medium SustainClosedJB CHARLESTON - HVAC SHOP
94680824643B - 464 - WT - HVAC - Rm 211 Too Cold - Repair - M . Watson - 3/1/21 - SR2365370Requester called back at 1443hrs on 3/2/2021 to advise that the ambient temperature is still 55 degrees and there is currently no airflow through the vents. SSgt Schleuger

Checked boiler, Tracer, air switch; still tracking down problem. JPB 3/2/2021

Adjusted CWV. JPB 5/11/20213B - Medium SustainClosedJB CHARLESTON - HVAC SHOP
96077634663A - 466 - WT - HVAC - No Hot Water In Bldg - Repair - Levi Shanks - 03/29/21 - SR 2398031Flame failure, reset. JPB 3/29/20213A - High SustainClosedJB CHARLESTON - HVAC SHOP
99901054643A - 464 - WT - Electric - Multiple Emergency Lights Out in Building 464 - Repair - M. Watson - 5/14/21 - SR2457422rplc'd 12 emergency lights3A - High SustainClosedJB CHARLESTON - ELECTRICAL SYSTEMS
113561694643A - 464 - WT - Electrical - Emergency Light Not Working Properly in Room 102,123,126,215,223,237,307 and 332 - RPR - L. Teague - 5/12/22 -SR2922516 May - Replaced 8 emergency lights (material on hand)3B - Medium SustainClosedJB CHARLESTON - ELECTRICAL SYSTEMS
117781634793B - 479 - WT - Electric - Range Hood and Light Not Working in Room 229 Kitchen - Repair - B. Bainter - 8/24/22 - SR309597829 Aug 22. Troubleshot circuit for range exhaust hood. Repaired light, however exhaust fan was not working. check for power at connections and power is good. Need to transfer to HVAC for the exhaust motor of the hood range. Rogers
Parts used from interior shed.3B - Medium SustainClosedJB CHARLESTON - ELECTRICAL SYSTEMS
118887184603B - 460 - WT - Electrical - Two Light Fixtures Out in 1st Floor Laundry Room - RPR - J. Humble - 9/15/22 - SR313485520 Sept 22. Search for lights that can be used to replaced the current ones. Tuned breaker off for laundry room lighting. Replaced fixures. Restored power and checked for proper operation. Clark.3B - Medium SustainClosedJB CHARLESTON - ELECTRICAL SYSTEMS
119348344603B - 460 - WT - Structures - Clean Gutters - Repair - SSgt Hines - 09/22/2209/22/2022 - Cleaned gutters3B - Medium SustainClosedJB CHARLESTON - STRUCTURE SHOP
121231484613B - 461 - WT - Electric - 2nd Flr next to Rm 309 busted Security Light - RPR - 11/9/2022 - SR 322010413 Dec 22. Replaced security light. Rogers/Vaughn3B - Medium SustainClosedJB CHARLESTON - ELECTRICAL SYSTEMS
121426924603A - 460 - WT - Electric - Room 330 has an outlet next to the entry door where the top outlet is INOP. - RPR - Humble - 11/15/22 - SR 322753021 Nov 22. Replaced broken outlets for rm 330. Clark/Wang3A - High SustainClosedJB CHARLESTON - ELECTRICAL SYSTEMS
100966094683B - 468 - WT - Utilities - Pipe Burst on Outside of Facility - Repair - TSgt Dixon - 06/08/21Replaced broken spigot3B - Medium SustainClosedJB CHARLESTON - WATER AND FUELS SYSTEM MX
101064654683A - 468 - WT - HVAC - Inv/ Repair HVAC in the kitchen isn't working - Repair - C. Balter - 6/11/21 - SR2489658Turned off AHU in the attic. Checked all other units and everything is normal operation. JPB 6/11/20213A - High SustainClosedJB CHARLESTON - HVAC SHOP
105314034683A - 468 - WT - HVAC - Repair 2 Walk In Freezers - Repair - TSgt Howard - 09/20/2021Need to order fan switch / fan. JPB 9/21/2021
Installed fans and switch. Complete. RWH/10/05/21.3A - High SustainClosedJB CHARLESTON - HVAC SHOP
109464784683B - 468 - WT - Structures - Repair Ceiling Drywall Near Entrance Foyer - Repair - R. Singleton - 01/26/22 - SR 2763853cut and replaced drywall

sanded and applied second coat of mud

03/01/2022 - tile replaced.3B - Medium SustainClosedJB CHARLESTON - STRUCTURE SHOP
59270914683A - 468 - WT - HVAC - No A/C Kitchen & Dish Rm Humid - Repair - MSgt Gooden - 05/17/19 - SR 1681917Both chillers at plant was down. Added oil to one system, while changed fuses for the other. Will monitor throughout the weekend (17 May 19)3A - High SustainClosedJB CHARLESTON - HVAC SHOP
94180044683B - 468 - WT - HVAC - Kitchen Ventilation Hood System INOP - Repair - Ms Saylor - 02/19/211 belt picked up. JPB 3/19/2021
Reference WT 9550772. JPB 4/15/20213B - Medium SustainClosedJB CHARLESTON - HVAC SHOP
76318004693B - 469 - WT - HVAC - Replace pump couplings - Repair - Lee Martin - 4/9/2020Coupling for CWP is bad. Researched and ordered replacement coupling (9 April 20) ETGS3B - Medium SustainClosedJB CHARLESTON - HVAC SHOP
20538874613A - 461 - WT - Utilities - (C0291) Resident states toilet wont flush - Repair - SSgt Scott - 03/06/173A - High SustainClosedJB CHARLESTON - WATER AND FUELS SYSTEM MX
20540164793A - 479 - WT - Utilities - (C0292) Unclog sink - Repair - SSgt Christopher - 03/06/173A - High SustainClosedJB CHARLESTON - WATER AND FUELS SYSTEM MX
24238644603A - 460 - WT - Utilities - Repair Toilet in Rm 335 - Repair - SSgt Scott - 5/18/20173A - High SustainClosedJB CHARLESTON - WATER AND FUELS SYSTEM MX
24408724643C - 464 - WT - Utilities - Rpl water spigot, by storage locker/stairs 1st fl - Repair - M. Brewington - 05/22/17 - SR 11294193C - Low SustainClosedJB CHARLESTON - WATER AND FUELS SYSTEM MX
24429174613C - 461 - WT - Structures - Rpl/Rpr maintenance Bldg door for dorms - Repair - Sgt Scott - 05/22/17 - SR 11296303C - Low SustainClosedJB CHARLESTON - STRUCTURE SHOP
28029224603B - 460 - WT - HVAC - Investigate Water Leak - Repair - TSgt Pearson - 8/16/173B - Medium SustainClosedJB CHARLESTON - HVAC SHOP
33539974601 - 460 - WT - HVAC - Inv/Rpr overflowing boiler for Bldg - Repair - SSgt Pearson - 12/27/17Pressure gauge rusted off. Capped hole, leaked abated.1-EmergencyClosedJB CHARLESTON - HVAC SHOP
59131544603B - 460 - WT - Structures - RPR Sheetrock on Ceiling of Room 124 from Leak - Repair - L. Shanks - 05/15/19 - SR 1679284- 23 May 2019 - hung Sheetrock

- 30 May 2019 - added 2nd coat of mud

- 4 Jun 2019 - needs paint (structures complete)3B - Medium SustainClosedJB CHARLESTON - STRUCTURE SHOP
119702924613B - 461 - WT - Electric - Busted Security Light - Repair - Humble - 09/29/22 - SR 31583315 Oct 22. Replaced wall pack fixture. Clark/Wang
Used parts from interior shed.3B - Medium SustainClosedJB CHARLESTON - ELECTRICAL SYSTEMS
DKFXAH0333WW49104693A - 469 - WT - HVAC - RPL CHILL WATER PUMP MEETER - Repair - Sgt Oliver - 01/10/173A - High SustainClosedJB CHARLESTON - HVAC SHOP
47847084603A - 460 - WT - Utilities - Unclog 1st Floor Water Line - Repair - L. Shanks - 09/20/18 - SR 1472920Unclogged Sewer line3A - High SustainClosedJB CHARLESTON - WATER AND FUELS SYSTEM MX
20233454663B - 466 - WT - Structures - (C0103) Replace Carpet and paint room - Repair - MSgt Woodcock - 01/24/173B - Medium SustainClosedJB CHARLESTON - STRUCTURE SHOP
22717074603B - 460 - WT - HVAC - (B181) A/C Inop - Repair - TSgt Woodcock - 3/2/173B - Medium SustainClosedJB CHARLESTON - HVAC SHOP
24343454603A - 460 - WT - Utilities - Unclog Kitchen Sink in Rm 140 - Repair - TSgt Pearson - 5/19/2017 - SR 11286943A - High SustainClosedJB CHARLESTON - WATER AND FUELS SYSTEM MX
54498464613B - 461 - WT - Electric - Storage RMs on 1st & 2nd Lights Out - Repair - TSgt Herron - 02/14/19 - SR 1591313changed 6 ballasts3B - Medium SustainClosedJB CHARLESTON - ELECTRICAL SYSTEMS
57801414613A - 461 - WT - Electric - Rm 204C Lights And Outlets Not Working - Repair - Christina Herron - 04/18/19 - SR 165108618 Apr 2018 - Parts Needed

25 Apr 2019 Parts on order 16 Jul 2109 Outlets installed

3A - High SustainClosedJB CHARLESTON - ELECTRICAL SYSTEMS
61073434603B - 460 - WT - Utilities - Extend Mixing Valve - Repair - Sgt Metts - 06/27/19cut hole in wall and moved mixing valve3B - Medium SustainClosedJB CHARLESTON - WATER AND FUELS SYSTEM MX
63097054603B - 460 - WT - Electric - North And Center Stairwells Of Bldg 460 Lights Are Out - Repair - Levi Shanks - 08/12/19 - SR 178122616Aug19 - The lights referenced have emergency ballasts. We cannot direct wire these fixtures without hybrid bulbs. We are forced to replace the ballasts. At the COB, we are still replacing ballasts. Will have to pick it back up on Monday, 19Aug19.

6apr20-2 lights remaining to be repaired.

8apr20-all lights repaired.3B - Medium SustainClosedJB CHARLESTON - ELECTRICAL SYSTEMS
66945484733B - 473 - WT - Utilities - 1st Flr Laundry Rm Drain Clogged - Repair - Levi Shanks - 10/15/19 - SR 1854844Snaked and cobra-ed the line3B - Medium SustainClosedJB CHARLESTON - WATER AND FUELS SYSTEM MX
68897884603B - 460 - WT - Utilities - Rm 240 Vanity Sink Clogged - Repair - Levi Shanks - 11/19/19 - SR 1896148Snaked Sink3B - Medium SustainClosedJB CHARLESTON - WATER AND FUELS SYSTEM MX
59756184613B - 461 - WT - HVAC - Replace Filters/Belts - Repair - Sgt Oliver - 06/03/2019Replaced filters throughout the facility (25 Feb 20) ETGS3B - Medium SustainClosedJB CHARLESTON - HVAC SHOP
71397274793B - 479 - WT - Utilities - Rm 336 Vanity Sink Clogged - Repair - Miranda Watson - 01/09/20 - SR 1944013Snaked sink from the hole in the wall3B - Medium SustainClosedJB CHARLESTON - WATER AND FUELS SYSTEM MX
75205804603B - 460 - WT - HVAC - Multiple Rms Too Hot - Repair - Miranda Watson - 03/16/20 - SR 2021096Installed new freq drive, drive accessory wrong voltage. Researching replacement accessory (20 March 20) ETGS

Freq drive installation complete, working with Trane on communications issue (23 March 20) ETGS

SYS OPERATIONAL AMB 5/11/203B - Medium SustainClosedJB CHARLESTON - HVAC SHOP
77703844793B - 479 - WT - Utilities - Rm 232 P-Trap Cracked - Repair - Levi Shanks - 05/18/20 - SR 2063492Snaked Drain3B - Medium SustainClosedJB CHARLESTON - WATER AND FUELS SYSTEM MX
77772054793B - 479 - WT - Structures - Rpl/Rpr Vanity Cabinet In Rm 203 - Repair - Levi Shanks - 05/19/20 - SR 206504128may20- installed vanity/patched drywall

1June20 - installed doors / caulking completed 16Jun20 - Collected sample of fermica/ordered rplmt mats. C/O 25aug20 - attached formica

26aug20 - finished formica3B - Medium SustainClosedJB CHARLESTON - STRUCTURE SHOP
78461334603B - 460 - WT - HVAC - Rm 313 Too Hot - Repair - Miranda Watson - 06/05/20 - SR 2081832Checked entire system and VAV for room. Space temp is 73 degrees (12 June 20) ETGS3B - Medium SustainClosedJB CHARLESTON - HVAC SHOP
78873554613A - 461 - WT - HVAC - A/C Out In Whole Bldg - Repair - Levi Shanks - 06/11/20 - SR 2089341King valve for compressor has leak , repaired leak. Techs also found bad compressor. System still running at 50%. Currently researching new compressor (18 June 20) ETGS
Reference 80531663A - High SustainClosedJB CHARLESTON - HVAC SHOP
80007684643A - 464 - WT - HVAC - ROOM 130 AC INOP - LEVI SHANKS - 7/2/2020 - 2113061VAV had burnt wire. Hard wired system. System up and running (7 July 20) ETGS3A - High SustainClosedJB CHARLESTON - HVAC SHOP
80531664613A - 461 - WT - HVAC - AC Out In the Entire Building - Repair - Levi Shanks - 07/10/20 - SR 2120896(Previous comments removed due to character limit)

Pulling vacuum again to remove more moisture. JPB 10/13/2021 Compressor oil on order. RWH 10/15/21.

Added 1.5 Gal Oil48 to system; finished electrical; pulling vacuum. JPB 11/15/2021 Charged up ckt 2. Need to order crankcase heater. JPB 11/16/2021 Crankcase Heater on order. RWH 11/18/21 Installed crankcase heater; will verify wiring tomorrow & compressor phase rotation before start-up. JPB 12/1/2021

Circuit 2 up and running. Waiting on extra crankcase heater to come in before closing ticket. JPB 12/2/20213A - High SustainClosedJB CHARLESTON - HVAC SHOP
89097304603B - 460 - WT - HVAC - Air Handler Above Vanity/Closet In Rm 313 Making Loud Noise - Repair - Levi Shanks - 11/18/20 - SR 2270021Work Order Completed3B - Medium SustainClosedJB CHARLESTON - HVAC SHOP
102020124793B - 479 - WT - Structures - 2nd Fl Mech Rm Rpr/Rpl Sheetrock Covering Pipe - Repair - Mr Carter - 07/06/217/7/21 - Drywall patches

7/8/21 - 2nd Coat of mud

7/19/2021 - completed patch3B - Medium SustainClosedJB CHARLESTON - STRUCTURE SHOP
106722834643B - 464 - WT - HVAC - HVAC Leaking In Rm 317 - Repair - Tamaya Parks - 10/12/21 - SR 2650400Cleared drain line for 4 AHUs; cleaned up standing water in attic. JPB 10/12/20213B - Medium SustainClosedJB CHARLESTON - HVAC SHOP
98662434663B - 466 - WT - Structures - Repair Two Small Holes In Wall Of Rm 229 - Repair - Miranda Watson - 05/06/21 - SR 24465075/10/2021 - cut, repaired/mud3B - Medium SustainClosedJB CHARLESTON - STRUCTURE SHOP
99903024643B - 464 - WT - Electric - Inv/ Repair INOP All exit signs on 3rd floor - Repair - M. Watson - 5/14/21 - SR24574326 July - repairing exit signs.3B - Medium SustainClosedJB CHARLESTON - ELECTRICAL SYSTEMS
107920194793C - 479 - WT - Utilities - 1st floor supply closet sink is clogged - Repair - tamaya Parks - 11/22/2021 - SR 2697434Snaked sink3C - Low SustainClosedJB CHARLESTON - WATER AND FUELS SYSTEM MX
109954904603B - 460 - WT - HVAC - Repair Boiler - Repair - Mr Martin - 02/10/22Low water pressure alarm, cleaned a dirty sensor but getting low water alarm even though there's water flow. JPB 2/9/2022

Mended broken make-up water line, relief valve pops. Still investigating. JPB 2/10/2022 Mended pinholes around hot water loop. Still working on replacing relief valve on make-up water line. JPB 2/11/2022 Refilling hot water system with make-up water. JPB 2/14/2022

Fired off boiler & discovered the recirculating pump is leaking. Will order a new one. JOB 2/15/20223B - Medium SustainActiveJB CHARLESTON - HVAC SHOP
113259114603B - 460 - WT - Structures - Tile Replacement Around the Toilet in Room 107 - RPR - L. Teague - 5/4/22 - SR2908117replaced tile around toilet and grout.3B - Medium SustainClosedJB CHARLESTON - STRUCTURE SHOP
113540334793B - 479 - WT- Electric - Broken Exit Sign On 3rd Floor - Repair - L. Teague - 05/11/22 - SR 292149718 May - installed 2 new exit signs (material on hand)3B - Medium SustainClosedJB CHARLESTON - ELECTRICAL SYSTEMS
116242064793B - 479 - WT - Electric - Replace Emer Exit Sign On East Side Stairwell - Repair - Bainter - 7/14/22 - SR 3022559Rewired and mounted exit sign.3B - Medium SustainClosedJB CHARLESTON - ELECTRICAL SYSTEMS
118933734793B - 479 - WT - Electric - Dayroom Remove Lighting Fixtures - Repair - SSgt Hines - 09/14/2221 Sept 22. Disconnected and removed lights form dayroom for ceiling repairs. Rogers.3B - Medium SustainClosedJB CHARLESTON - ELECTRICAL SYSTEMS
119582464643B - 464 - WT - Structures -Hall - RPR Broken 1st step on the second floor in the Center Stairwell- RPR - K. Switzer - 9/28/22 - SR315468008 Nov 2022 - removed & replaced stair tread and damaged tile.3B - Medium SustainClosedJB CHARLESTON - STRUCTURE SHOP
120806054793A - 479 - WT - Electrical - Garbage disposal started smoking when powered Rm 329 - RPR - B. Bainter - 10/28/22 - SR32020503 Nov 22. garbage disposal motor is ceased and needs to be disconnected. Disconnected power to garbage disposal. FM needs to open a new WT when garbage disposal is replaced. Alge/German.3B - Medium SustainClosedJB CHARLESTON - ELECTRICAL SYSTEMS
121352244613B - 461 - WT - Electric - Room 303D bathroom outlet INOP - RPR - HUMBLE - 11/14/22 - SR 32239269 Dec 22. Changed bathroom outlet. Vaughn/Frank3B - Medium SustainClosedJB CHARLESTON - ELECTRICAL SYSTEMS
100940634681 - 468 - WT - Utilities - Pipe Burst on Outside of Facility - Repair - TSgt Hart - 06/08/21Isolated line. Created new WT to purchase parts.1-EmergencyClosedJB CHARLESTON - WATER AND FUELS SYSTEM MX
101040114683B - 468 - WT - Structures - Repair Ceiling Front Entrance Of Dinning Facility - Repair - C. Balter - 06/10/21 - SR 24887378/11/2021 - Cut hole in ceiling /HVAC repairing duct work

8/12/2021 - replaced drywall/first coat

8/25- hvac need to come back and repair3B - Medium SustainClosedJB CHARLESTON - STRUCTURE SHOP
117864094683A - 468 - WT - Electric - Reset Breaker - Repair - Brown - 8/25/2225 Aug 22. Investigate cause of breaker tripping. Searched for breaker, reset and test for proper operations. Alge/German.3A - High SustainClosedJB CHARLESTON - ELECTRICAL SYSTEMS
124503414683B - 468 - WT - HVAC - The dining room is colder than usual, and the storeroom is below 60 degrees - Repair - Howard - 1/24/23 - SR 3339255No comments left by technician. JPB 1/25/2023
Replaced pressure switch. JPB 1/31/20233B - Medium SustainActiveJB CHARLESTON - HVAC SHOP
52760684683C - 468 - WT - Lock Shop - REKEY BLDG From Contractors - Repair - TSgt Miller - 12/27/18 - SR 1554279duplicate3C - Low SustainClosedJB CHARLESTON - STRUCTURE SHOP
53195814683C - 468 - WT - Lock Shop - Inspect All BLDG Doors Panic Hardware for Proper Operation Before Feb 1 - Repair - C. Miller - 01/09/19 - SR 1562164Made all repairs - 22 Jan 20193C - Low SustainClosedJB CHARLESTON - STRUCTURE SHOP
53345844683B - 468 - WT - Lockshop - Need Keys Made - Repair - TSgt Miller - 01/15/2019building cores - 24 Jan 2019

Waiting new cores ordered through mat control 01/31/19 RMS

Built new cores and installed 5 Feb 20193B - Medium SustainClosedJB CHARLESTON - STRUCTURE SHOP
68114534681 - 468 - WT - HVAC - Repair Domestic Hot Water Boiler - Repair - Mr Martin - 11/04/19Troubleshot boiler. Part on order. Boiler operational. rwh/11/12/19.

Part received. rwh/11/21/19.

1-EmergencyClosedJB CHARLESTON - HVAC SHOP
69768014683B - 468 - WT - Electric - Inv Voltage Issue With Walk-In Freezer - Repair - Angela Gooded - 12/04/19 - SR 19117566 Dec 19- Voltage to freezer is 208 volts.3B - Medium SustainClosedJB CHARLESTON - ELECTRICAL SYSTEMS
29402134793A - 479 - WT - Utilities - Inv/Rpr circulation pump 1st fl mech rm - Repair - TSgt Brice - 09/25/17repair pump3A - High SustainClosedJB CHARLESTON - WATER AND FUELS SYSTEM MX
75714404793B - 479 - WT - Structures - Rpr Holes In Wall Of Rm 324 - Repair - Tamaya Parks - 03/25/20 - SR 20283124/16/20 - Installed 3 layers of sheetrock/added first coat C/O

4/17/20 - Sanded/applied second coat C/O 4/28/2020 - added 3rd coat

4/30/2020 - Final sanding needs paint3B - Medium SustainClosedJB CHARLESTON - STRUCTURE SHOP
110735584603B - 460 - WT - HVAC - Rm 218 Too Warm - Reapir - Lakendria Teague - 03/08/22 - SR 2820086Serviced all AHUs. AHU-4 actuator needs to be replaced. AHU-2 was running backwards. JPB 3/9/20223B - Medium SustainClosedJB CHARLESTON - HVAC SHOP
32207954733B - 473 - WT - HVAC - Prepare Boiler For Winter Season - Repair - Sgt Green - 11/20/2017Tested boiler and ensured all safeties are operational3B - Medium SustainClosedJB CHARLESTON - HVAC SHOP
33310224603A - 460 - WT - Utilities - Unclog vanity sink in room 117 - Repair - C. Scott - 12/19/17 - SR 12560143A - High SustainClosedJB CHARLESTON - WATER AND FUELS SYSTEM MX
37557714733B - 473 - WT - Utilities - Unclog Vanity Sink in Rm 312 - Repair - Daniel Pearson - 3/19/2018 - SR 1310347cleared drain3B - Medium SustainClosedJB CHARLESTON - WATER AND FUELS SYSTEM MX
37716504793B - 479 - WT - Electric - Repair/Replace Exit Sign - Repair - Sgt Pearson - 03/21/2018 - SR 13121143B - Medium SustainClosedJB CHARLESTON - ELECTRICAL SYSTEMS
38015634733A - 473 - WT - HVAC - Inv. / Repair Boiler Rm - Repair - Sgt Pearson - 03/23/2018 - SR 1314627Replaced boiler control module and reattached loose wiring3A - High SustainClosedJB CHARLESTON - HVAC SHOP
39770034603A - 460 - WT - Utilities - Unclog Sink For Room 306 Vanity - Repair - C. Scott - 04/17/18 - SR 133460cleared drain3A - High SustainClosedJB CHARLESTON - WATER AND FUELS SYSTEM MX
40457824663A - 466 - WT - Electric - Rpr/Rpl Emergency Lights Throughout Facility - Repair - D. Pearson - 05/02/18 - SR 1346475Replaced all emergency lights, Drennan.3A - High SustainClosedJB CHARLESTON - ELECTRICAL SYSTEMS
41325334603B - 460 - WT - Utilities - Unclog Vanity Sink in Rm 334 - Repair - Christopher Scott - 5/21/2018 - SR 1362556Got in wall to snake the line.3B - Medium SustainClosedJB CHARLESTON - WATER AND FUELS SYSTEM MX
41969244643A - 464 - WT - Structures (Griff) - Repair Leak in Ceiling Rm 320 - Repair - David Drannum - 6/1/2018 - SR 1372254No evidence of roof leak. Checking after rain. C/O3A - High SustainClosedJB CHARLESTON - STRUCTURE SHOP
42917974603B - 81164 - WT - Electric - Rpr Light that fell from entrance pole - Repair - C. Scott - 06/15/18 - SR 1386546Installed new LED light on 9 July 18 Drennan.3B - Medium SustainClosedJB CHARLESTON - ELECTRICAL SYSTEMS
43207974663B - 466 - WT - Utilities - RPR Vanity Sink P Trap leak in room 330 - Repair - C. Scott - 06/20/18 - SR 1390797The two members entered the restroom and identified the requesters Urgent work request. The drain seemed desolate in it's structural integrity. After a short assessment, it was determined that a total retrofit was necessary. The two of them began their quest for a leak free world that moment...they began by removing the nuts which shoddily held the p-trap to both the j tube and the drop tube. They knew it was all beyond reconstitution, so they discarded the material in the nearest waste container. They then used paper towels to clean the mess that unavoidably was caused by the construction. Once cleaned, they began redoing the piping. They installed an 1 1/4" pee trap and drop tube to the bottom side of the strainer that strains the water that people use to wash their hands. Immediately following that, they installed the J tube and efficiently inserted it into the wall...using a fresh trap adapter. They connected and tightened all fittings...the job was done. C slash.3B - Medium SustainClosedJB CHARLESTON - WATER AND FUELS SYSTEM MX
45346244613C - 461 - WT - Structures - RPR Dry Wall Near Restroom Ceiling for Room 204C - Repair - C. Sott - 08/06/18 - SR 1432527took out old dry wall investigated leak 8/21/20183C - Low SustainClosedJB CHARLESTON - STRUCTURE SHOP
45940754603A - 460 - WT - HVAC - RM 330 HVAC Water Leaking Through Light Fixture - Repair - SSgt Scott - 08/15/18Plumbers repaired leak in domestic hot water line. HVAC techs went out and restarted boiler/pumps.3A - High SustainClosedJB CHARLESTON - HVAC SHOP
45998204613B - 461 - WT - HVAC - No AC RM 212A - Repair - Sgt Scott - 08/17/2018 - SR 1443337VAV was tripped on air flow. Cleaned pitot tube and reset unit. Unit running 100%
Also checked AHU that supports room. Checked belts and filters3B - Medium SustainClosedJB CHARLESTON - HVAC SHOP
46002294663B - 466 - WT - HVAC - RM 112 To Hot - Repair - Sgt Herron - 08/17/2018 - SR 1443435VAV was tripped on air flow. Cleaned pitot tube and reset unit. Unit running 100%3B - Medium SustainClosedJB CHARLESTON - HVAC SHOP
49306244793C - 479 - WT - Utilities - Rm 131 Vanity Sink Clogged - Repair - SSgt Shanks - 10/15/18 - SR 1496015spent forever snaking drain3C - Low SustainClosedJB CHARLESTON - WATER AND FUELS SYSTEM MX
49487594613A - 461 - WT - Utilities - Unclog Kitchen Sink and Repair Leak for Room 107 - Repair - D. Pearson - 10/18/18 - SR 1501026Drained sink and then snaked it3A - High SustainClosedJB CHARLESTON - WATER AND FUELS SYSTEM MX
20454264793A - 479 - WT - Utilities - Bathroom Sink Leaking Rm 135 - Repair - SSgt Christopher Scott - 3/27/20173A - High SustainClosedJB CHARLESTON - WATER AND FUELS SYSTEM MX
20634894643A - 464 - WT - Utilities - (C0283) Ceiling is leaking water, coming from the kitchen above them - Repair - MSgt Woodcock - 02/02/173A - High SustainClosedJB CHARLESTON - WATER AND FUELS SYSTEM MX